Loading...
HomeMy WebLinkAboutB06-0196 Fire Dampers w/sleeves Sumittal DataManufacturer: Ruskin Spec. Section 15880-2,10 Fire Dampers w/sleeves SU-1 Job Contractor Engineer: Submitted By: Submittal: Date: )Mitt . Data Four Seasons Resort - Vail Cherringtons :.,Rybka Smith & Ginsler Inc. t-ONG Building .Environments One June 4, 2007 by: S.G. LONG BUILDING EN VI ROINMENTS 4689 So. Cherry St. Murray UT 84123 I 801-262-5664 fax 801-264-8884 AMON& RUSKIIN 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 PIS- 40r,fi0 WTYLE.?B' CURTAIN TYPE=DYNAMIC FIRE DAMPERS 1 /2 HOURUI 5$S13ATED F..O USE•IN DYNAMIC gNDW ..-IC.SYSTEMS APPLICATION The Models DIBD20, 40 and 60 can be installed vertically in walls or horizontally In floors with fire resistance ratings of leas than 3 hours. The DIBD20, 40, 60 carry a 11/2 hour UL fire damper label and are classified as dynamic dampers for ties in HVAC systems that remain in operation during a fire. DYNAMIC CLOSURE RATINGS MAXIMUM VELOCITY - 2,000 Ipm (10.16 m/s) on all sizes. MAXIMUM PRESSURE-41n. w.g. (1kPa). STANDARD CONSTRUCTION FRAMEISLEEVE DIBD20 - 20 gage x 12" (1.0.x 305) galvanized, steel channel. DIBD40 - 20 gage x 14" (1.0 x 356) galvanized, steel channel. DIBD60 - 20 gage x 16" (1.0 x 406) galvanized, steel channel. BLADES 24 gage (.7) galvanized curtain type. CLOSURE SPRINGS 301 stainless steel constant force or spring clip type. FUSIBLE LINK 165°F (74°C) is standard. 212"F (100°C) and 2851F (141 °C) are available. DAMPER SIZES MINIMUM SIZE Vertical Installation - 6"w x 4"h (152 x 102) Horizontal Installation - 6"w x 4"h (152 x 102)-for dampers no larger than 24"w or 21"h'(610 or 533). Dampers larger than 24"w or 21'h (610 or 533) have a minimum size of 1 O"w or 8"h (254 or 203). MAXIMUM SIZE Single Section Vertical Installation - 33"w x 32'h (838 x 813) Horizontal Installation- 24"w x 21"h (610 x 533) Multiple Section Vertical InstallatiDn - 72"w x 454h (1829 x 1143),46"w x 69"h (1219 x 1753) or 84"w x 21 "h (2134 x 533) Horizontal Installation- 36'w x 42"h (914 x 1067) OPTIONS FM Appra wed as FAST Angle for one side angle installation 151191516 fat SeMy-al".- COMP1101160 Will, lei to 0 NOTE: Dimensions shown In parentheses( ) indicate mlllirneters. Models DIBD2D, 40, 60 meet the requirements for fire, dampers established by: • National Fire Protection Association NFPA Standards 90A and 101 • BOCA National Building Codes • ICBO Uniform Building Codes • SBCCI Standard Building Codes • ICC International Building Codes • CSFM California State Fire Marshal Fire Damper Listing (#3225-245:005) • New York City (BSA Listing #297-71-SA) F UL CLASSfing UL55b L 3i SEE COM MARK NGPLETE pM SPECIFICATION TESTED PRODUCT C M ON PRODUCT APPROVED (OPTION) .VERTICAL MOUNT -1 C- 1112" (39) L L = Frame/Sleeve Length HORIZONTAL MOUNT Spac DISMOB-7061Replacea DIBD208.eo4 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. OpusWn2006 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 • FAX (816) 765-8955 lIJB`D20~1 GIat80x L~Er~4 .UfitT~AIN TY'PE~D`f( I~'MlCefifRE'D/a►NiPER'~ 11LxtHQUR~IJLS53 R'IkTLD FOfi. USE'IN:D'NAMIC:IANO 5T'ATIC'SYSTEtNS APPLICATION DIB020, 40, 6o fire dampers can be Installed vertically In walls or horizontally in floors with fire resistance ratings of less than 3 hours. The DIBD20, 40, 60 carry a 11/2 hour UL fire damper label and are classified as a dynamic damper for use In HVAC systems that remain in operation during a We. DYNAMIC CLOSURE RATINGS MAXIMUM VELOCITY -2,000 fpm (10.16 m/s) on all sizes. MAXIMUM PRESSURE - 4 In. w.g. (1 We). STANDARD CONSTRUCTION FRAME/SLEEVE DIBD20 - 20 gage x 12" (1.0 x 305) galvanized, steel channel. DIBD40 - 20 gage x 14" (1.0 x 3561 galvanized, steel channel. -----~DIBD80 - 20 gage x 16" (1.0 x 406) galvanized, steel channel. BLADES 24 gage (.7) galvanized curtain type. CLOSURE SPRINGS 301 stainless steel constant force or spring clip type. FUSIBLE LINK 165•F (74•C) Is standard. 2121F (100•C) and 285•F (141 •C) are available, MINIMUM SIZE DAMPER SIZES . Vertical Installation - 4"w x 4"h (102 x 102) Horizontal Installation - 6"w x 6"h (152 x 152) for dampers no larger than 24"w or 24"h (610 or 610). Dampers larger than 24"w or 24"h (610 or 610) have a minimum size of 10"w or 10"h (254 or 254). MAXIMUM SIZE Single Section Vertlcal.lnstallation- 33"w x 36"h (838 x 914) Hotlzontal-Installation - 245w x 24"h (610 x 610) Multiple Section Vertical Installation - 72"w x 48"h (1899 x 1219), 48'w x 72"h (1219 x 1829) or 84"w x 24"h (2134 x 6.10) Horizontal Installation - 361w x 48"h (914 x 1219) OPTIONS FAST Angle for one side angle installation My. affl I. 0= n NOTE: Dimensions shown in parentheses indicate millimeters. L c Frame/Sleeve Length HORIZONTAL MOUNT Spot DISD20A-1106111eplaces DIW20A-706 ALL STATED SPECIFICA77ONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Models DIBD20, 40, 60 meet the requirements for fire, dampers established by: • National Fire Protection Association NFPA Standards 90A and 101 • BOCA National Building Codes • ICBO Uniform Building Codes • SBCCI Standard Building Codes • ICC Intern8tional Building Codes • CSFM California State Fire Marshal Fire Damper Listing (53225-245:005) • New York City (BSA Listing #297-71-SA) UL CLASSIFIED UL556 Listing R5531 ilP/4,SEE COMPLETE FM SPECIFICATION MARKINl3 TESTED PRODUCT c iv 1It ON PRODUCT APPIMED (OPTION) VERTICAL MOUNT I-- L ORusldn 2006 C7 L`Y 0 ASSEMBLY AND DIMENSIONAL INFORMATION Dampers are normally fabrlcated approximately 1/4" (6) less than given duct dimensions. Duct collars (Style CA, CO, etc.) are normally fabricated approximately 1/8" (3) less than given duct dimensions. If flange connections like TDF, Ward or Ductmate are to be used, order the damper and sleeve assembly actual size. Refer to the Assembly and Dimensional Information Data Sheet for specific dimensional information, SUGGESTED SPECIFICATION Furnish and Install, at locations shown on the plans, dynamic fire dampers tested, constructed and labeled in accordance with the latest edition of UL Standard 555. Dampers shall have a fire rating of 11/2 hours and shall meet the requirements of the latest edition of NFPA90A. Each damper shall include a 165°F (74°C) or 212°F (100°C) fusible link (specifier select) and shall be labeled for use in dynamic systems, Dampers labeled for use in static systems only are not permitted. The damper shall be rated for dynamic closure to a minimum 2000 fpm (10.16 rn1s) and 4 inches w.g. (f kPa) static pressure and shall be rated to close with alrflow in either direction. Each dynamic fire damper shall include a 12", 14" or 16" (305, 356 or 406) (specifier select) long integral roll formed steel sleeve and mounting angles furnished by the damper manufacturer to ensure appropriate Installation. Submittal Information shall include the fire protection rating, maximum velocity/pressure rat- ings and the manufacturer's UL installation instructions. The dampers shall be installed in accordance with the manufacturer's UL installation instructions. Dynamic fire dampers shall be curtain type Ruskin model DIBD20 with 12" (305) sleeve, DIBD40 with 14" (356) sleeve or DIBD60 with 16" (406) sleeve (specifier select). LABOR SAVER ACCESSORY OPTIONS TDF OR DUCTMATE BREAKAWAY CONNECTIONS Meet UL breakaway connection requirements without chang- ing connectors. Ruskin fire dampers can be installed using non-matched flange connections for the breakaway require- ment. Any flange connection can mate to a different type or model on Ruskin fire dampers. FAST mounting angles are used in lieu of conventional, eight piece mounting angles and are installed on only one side of the wall when used with Ruskin fire dampers. The FAST angle can be fairtened directly to the metal stud underneath the fire rated gypsum wallboard. QN1% 3600 Dr. Oreaves Rd. Kansas 011y. MD 64030 (818) 781-7A76 FAX (816) 765•a655 www_ruskin.com FAST MOUNTING ANGLES 0 ASSEMBLY AND DIMENSIONAL INFORMATION Dampers are normally fabricated approximately 114" (6) less than given duct dimensions. Duct collars (Style CR, CO, etc.) are normally fabricated approximately 11E" (3) less than given duct dimensions, SUGGESTED SPECIFICATION It flange connections like TDF, Ward or Ductmate are to be used, order the damper and sleeve assembly actual size. Refer to the Assembly and Dimensional Information Data Sheet for specific dimensional Information. Furnish and install, at locations shown on the plans, dynamic fire dampers tested, constructed and labeled in accordance with the latest edition of UL Standard 555. Dampers shall have a fire rating of 11/2 hours and shall meet the requirements of the latest edition of NFPA90A. Each damper shall include a 165°F (7400) or 212°F (100°C) fusible link (specifier select) and shall be labeled for use In dynamic systems. Dampers labeled for use in static systems only are not permitted. The damper shall be rated for dynamic closure to a minimum 2000 fpm (10.16 RNs) and 4 Inches w.g. (1 kPa) static pressure and shall be rated to close with airflow in either direction. LABOR SAVER ACCESSORY OPTION Each dynamic fire damper shall include a 12", 14" or 16" (305, 356 or 406) (specifier select) long Integral roll formed steel sleeve and mounting angles furnished by the damper manufacturer to ensure appropriate installation. Submittal information shall include the fire protection rating, maximum velocity/pressure rat- Ings and the manufacturer's UL Installation Instructions. The dampers shall be Installed in accordance with the manufacturer's UL installation instructions. Dynamic fire dampers shall be curtain type Ruskin model DIBD20 with 12" (305) sleeve, DIBD40 with 14" (356) sleeve or DIBD60 with 16" (406) sleeve (specifier se/ecn. FAST MOUNTING ANGLES A FAST mounting angles are used in lieu of conven- tional, eight piece mounting angles and are installed on only one side of the wall when used with Ruskin fire dampers. The FAST angle can be fastened directly to the metal stud underneath the lire rated gypsum wallboard. 3900 Di. Orsaves Rd. { r ® Kansas C141. MO 64030 1 (816) 761.7476 ,d ',`•r . i FAX (616) 765.8955 www.rusldn.com 0 RUSK`1N---' 3900 Dr. Greaves Rd Kansas City, MO 64030 (816) 761-7476 I FAX (816) 765-8955 APPLICATION DIBD2o, 40 and 60 fire dampers can be Installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. The DIBD20, 40 and 60 carry a 11/2 hour UL fire damper label and are classified as dynamic dampers for use in HVAC sys- tems that remain In operation during a fire. DYNAMIC CLOSURE RATINGS.1 MAXIMUM VELOCITY - 2,000 fpm (10.16 rnls) ohall sizes. MAXIMUM PRESSURE -4 in. w.g. (1 kPa). STANDARD CONSTRUCT113N FRAME/SLEEVE DIBD20 - 20 gage x 12' (1.0 x 305) galvanized, steel channel. DIBD40 - 20 gage x 14" (1.0 x 356) galvanized, steel channel. DIBD60 - 20 gage x 18" (1.0 x 406) galvanized, steel channel. BLADES 24 gage (.7) galvanized curtain type. CLOSURE SPRINGS 301 stainless steel constant force or spring clip type. FUSIBLE LINK 165•F (74•C) is standard. 212OF (100°C) a 9d 285•F (141°C). are available. DAMPER SIZES MINIMUM SIZE Vertical Installation Style CR - 3" (76) diameter Style C, CO - 4"w x 3'h (102 x 78) Horizontal Installation Style CR -4" (102) diameter Style C, CO - 4"w x 3"h (102 x 76) MAXIMUM SIZE Vertical Installation Style CR - 31" (787) diameter Style-C, CO - 31 "w x 31 "h (787 x 787) Horizontal Installation Style CR - 20" (508) diameter Style C, CO - 22w x 20"h (559 x 508) OPTIONS ;T• FAST Angle for one side angle Installation Sloe". e+V "im9n sleeve 49---"- F! Festal, Models DIBD20, 40 and 60 most the requirements for fire dampers established by: • National Fire Protection Association NFPA Standards 90A and 101 C • Bor 'A National Building Codes • ICBO Uniform Building Codes • BC CI Standard Bullding Codes • ICC.International Building Codes • CSFM California State Fire Marshal Fire Damper Listing (413225-245:005) • :New York City (BSA Listing #297-71-SA) UL CLASSIFIED UL666 Listing R5531 SEE COMPLETE FN1 SPECIFICATION MARKING TESTED PRODUCT C ~ ON PRODUCT APPROVED (OPTION) FEATURES The DIBD20, 40 and 60 Style c, CR, CO offer: • Taped and sealed round, rectangular or oval transitlon for medium pressure, 100% free area applications. STYLE C NOTE: Dimensions shown in parentheses ( ) indicate millimeters. :7 STYLE CR Spec DIBD20C-706/Repgces OIBD2oCR-604 ALL STATED SPECIFICATIONS ARE SUBJECT -To CHANGE WIrHOUT N077CE OR OBLIGATION. mRuskin 2008 STYLE CO ASSEMBLY AND DIMENSIONAL INFORMATION Dampers are normally fabricated approximately 114" (6) less If flange connections like TDF, Ward or Ductmate are to be used, than given duct dimensions. Duct collars (Style CR, Co, etc.) are order the damper and sleeve assembly actual size. Refer to the dimensions. normally fabricated approximately 1/8" (3) less than given duct Assembly and Dimensional Information Data Sheet for specific dimensional information. SUGGESTED SPECIFICATION Furnish and install, at locations sho d wn on ampers tested, constructed and labeled n acco ance dnamic fire latest edition of UL Standard 555. Dampers shall have a fire rating of 11/2 hours and shall meet the requirements of the latest edition of NFPA90A. Each damper shall include a 165°F (74"C) or 212°F (100°C) fusible link (specifier select) and shall be labeled for use in dynamic systems. Dampers labeled for use in static systems only are not permitted. The damper shall be rated for dynamic closure to a minimum 2000 fpm (10.16 m/s) and 4 inches w.g. (1 kPa) static pressure and shall be rated to close with airflow in either direction. Each dynamic fire damper shall include a 12", 14" or 16" (305, 356 or 406) (specifier select) long integral roll formed steel sleeve and mounting angles furnished by the damper manufacturer to ensure appropriate installation. Submittal information shall Include the fire protection rating, maximum velocity/pressure rat- ings and the manufacturer's UL installation Instructions. The dampers shall be installed in accordance with the manufacturer's UL Installation Instructions. Dynamic fire dampers shall be curtain type Ruskin model DIBD20 with 12" (305) sleeve, DBD40 with 14" (366) sleeve or DI8D80 with 16" (406) sleeve (specifier select). LABOR SAVER ACCESSORY OPTIONS E FAST mounting angles are used in lieu of conventional, eight piece mounting angles and are installed on only one side of the l The FAST angle can be fastened directly to the metal stud underneath the fire rated gypsum wallboard. 3906 or. Greaves Rd. t' Karnes CRY. MO 64636 r ' (816)781 FAX 7476 j FAX (816) 78ra-6855 www.rualdacam TDF OR DUCTMATE BREAKAWAY CONNECTIONS Meet UL breakaway connection requirements without chang- Ing connectors. Ruskin fire dampers can be installed using non-matchd flange connections for the breakaway require- ment. Any flange connection can mate to a different type or model on Ruskin fire dampers. FAST MOUNTING ANGLES I- Manufacturer: Ruskin Spec. Section Fire Smoke Dampers w/sleeves Subillittal Data io .Job Contractor Engineer: Submitted By: Submittal: Date: 04"N G Four Seasons Resort - Vail Cherrington's Rybka Smith & Ginsler Inc. LONG Building Environments One 09-Oct-2007 by: db BUILDING ENVIRONMENTS 4689 So. Cherry St. Murray UT 84123 801-262-5664 fax 801-264-8884 16 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 11/2 :HOUR UL555 RATED, APPLICATION The FSD36 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that pro- vides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. T he FS036 may be installed vertically in walls or horizontally in concrete floors, flow in either direction with v lodciti s t 2,000 fpm a dtpres pressures to 4" w.g. (Consult Ruskin for proper application It velocity and pres- sure exceed those listed above). Ell STANDARD CONSTRUCTION FRAME 54 x 16 (127 x 1.6) gage galvanized hat-shaped steel channel structurally superior to 13 (2.3) gage channel frame. BLADES 6" (152) wide, 16 (1.6) gage galvanized steel. Triple V-groove shaped approximately 6" (152) on center, BEARINGS Stainless steel sleeve pressed into frame. JAMB SEALS Stainless steel, flexible metal compression type. BLADESEALS Silicone edge type for smoke seal to 450•F (232"C) and galva- nized steel for flame seal to 1900•F (I o36•C). LINKAGE Concealed in frame. CONTROLLED CLOSURE DEVICE (HEAT-ACTUATED) EFL (Electric Fuse Link) -165•F (74"C) standard. 212"F (loo"C), 250"F (1210C), or 350"F (177"C) are options, PFL (Pneumatic Fuse Link) - 165•F (74•C) standard. 212"F (100•C) or 285°F (141.0) are options. UL555S Elevated Temperature.Rating 250"F (121 "C) or 350•F (177"C) depending on actuator. MINIMUM SIZE DAMPER SIZES 8"w x 6"h (203 x 152), MAXIMUM SIZE Vertical - 126"w x 96"h (3200 x 2438) or 72"w x 122"h (1829 x 3099). Horizontal Installation -144"w x 96"h (3858 x 2438). OPTIONS FM Armpfaveelaa apse t. • FAST Angle factory supplied for labor saving angle one-side / - Installation. ji - NOTES I. Dampers are furnished approximately 1/4,,(6) smaller than given opening dimensions. 2- Dimensions shown in parentheses( )indicate miiiirneters. Model FSD36 meets the requirements for fire, smoke and combination fire/smoke dampers established by: • National Fire Protection Association NFPA Standards 90A, 92A, 92B and 101 • BOCA National Building Codes • ICBO Uniform Building Codes • SBCCI Standard Building Codes • ICC International Building Codes • CSFM California. State Fire Marshal Fire Damper Listing (#3225-245:005 and Smoke Damper Listing (#3230- 245:109) • New York City (BSA Listing 4 176-82-SM) UL CLASSIFIED UL555 Listing R5531, UL555S Listing R5531 - MARKINGPLETE SPECIFICATION C~~ ON PRODUCT ~ TESTED PRODUCT APPROVED (OPTK)N) The FSD36 offers; FEATURES • EFL (Electricactuated Fuse link) or PFL (Pneumatic Fuse Llnk) heat-- release devices permit controlled (rather than instanta neous) closure through the damper actuator. The EFL and PFL allow the damper to automatically reopen after a test, smoke detection or power failure condition. • EFL is standard on dampers with electric actuator;, • PFL is standard on dampers with pneumatic actuators. • EFL's may be ordered on dampers with pneumatic actuators but require an additional EP switch. Height Spec FS036.606/80placn F3036-606 ALL STATED SPECIFICA TIONS ARE SUBJECT TO CHANGE WITH OUTNaT/CE OR OBLIGATION. ®Ruskin 2GGG :AMCA LICENSED R~U'S, K-lNi; v 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 - FAX (816) 765-8955 FAST and PFMA U Angle shown over MeteIANood Stud ' gypboard Wall or concrete Wall/Floor \ Fasten angle directly through gypboard Into wall and damper .sleeve on either side of wail or r concrete floor Fire/Smoke damper shown Fire damper also approved FIGURE 1 APPLICATION -WALLS AND CONCRETE FLOORS Ruskin FAST and PFMA are 20 gauge steel mounting angles designed and approved for use speclflcally•1ivilh Ruskin fire and fire/smoke dampers. Unlike conventional mounting angles that can- not be fastened together in the comers and ship separately from the dampers, the FAST and PFMA are: • One piece angles (fastened together in the corners) • Shipped loose around damper • Provided with pre-punched sleeve fastener holes on 2" (51) centers. The Ruskin FAST and PFMA make fire and fire/smoke damper installation easier and less costly: FAST- One Side Angle (Fig 1 & Fig 2) The Ruskin FAST angle is designed and UL approved for use with Ruskin 11/2 hour rated fire and combination fire/smoke dampers. An angle on "one side" is approved for opening sizes 90"w x 48"h (2286 x 1219) or 48"w x 90"h (1219 x 2286) in metal stud, wood stud walls or concrete/masonry walls and floors. For one side angle Installations the FAST must be fastened to the damper sleeve and partition in accordance with the damper basic instailatlon instructions. PFMA - Two Side Angles (FIg 3) The Ruskin PFMA is designed and UL approved for Liss with Ruskin 11/2 or 3 hour fire and fire/smoke dampers when two angle installations are required or desired. PFMA are installed on both sides of the partition and fastened only to the damper sleeve in accordance with the damper basic installation instructions. Dimensions shown in parentheses( ) indicate millimeters. Angle shown behind awboard Metal Stud only Fasten angle directly to metal stud and sleeve on either side of wall Fire damper shown Fire/Smoke Damper also approved FIGURE 2 MetalMood Stud Wall or Concrete wa111Floor PIMA Installed on \ both sides of I wall concrete floor Fasten PFMA to sleeve only Fire/smoke damper shown, Fire Damper also approved FIGURE 3 c,~VUL d SEE COMPLETE MARKING ON PRODUCT Spec FAST-7021Replacps FAST-102 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. 0 Ri iskin 2On2 SPACE ENVELOPE o~ n 6leaurrrafly mounted actuator$ r0mk space cuiside nm Asmnor W0,00, The "S" dimension is Ihtrb"l~eillda"'clearance, the '7 Oman- 4i0'fsthe "top" clearance alb} "'~''"tdknension is the W.W. olelarance required for the vari6waaWfors approved for use vA Ruskin fire/srpoke dampers. Actudlars and accessories are factory I mounted on the right side when viewed from the actuator side of the wall or floor. Ruskin fire/smoke dampers can be rotated or 1 turmcl over to accommodate 1he Appkation. If the actuator muss be mounted on top or bottom, select the FSD60V. The most commonly used electric actuators are shown in the table below. Refer to the Actuators And Accessories Space Envelopes For All Fire and Smoke Dampers data sheet for actu- ators and space information not shown. r 'r Motor with EFL or TS-150 I 1 I 1 B t 1 fI Ls_1 DAMPER SLEEVE DIMENSIONAL DATA {Darnptir S T .13 Netgltt). , M1,4202, H2000, H2024 15"(381) 4'(102) 01-(0) N/A MS4209, MS8209 15"(381) 4"(102) 0" (0) N/A MS4120, MS8120 17" (432) 5" (127) 0" (0) N/A FSNF120, GGD221 17" (432 5" (127) 0" (0) N/A NOTES: I . The "H" dimension represents the required height to encompass the actuator and accessories with nothing protruding above or below the damper. 2.sho The "wn.B" (bottom) dimension does Not Apply to the "H" sizes The MS4120 below the damper , MS8120, FSNF120 and GGD221 will hang on sizes 10" (254) high and shorter. The drawing and corresponding table show the position of the damper when mounted In a factory sleeve. The standard mounting locations provide enough space for the mounting of actuators, con- suit trols and Ruskin for allow space for installation of retaining angles and duct connections. The mfNntum factory sleeve length is 17" (432). shorter sleeve lengths, Con- The standard location of a damper mounted in a factory sleeve dimension) is shown at right. NOTE: The entire damper frame Is not required to be installed within the wall. The damper blades, when closed should be contained within the wall. "Minlmum Sleeve Length Formula: Sleeve Length . "L" dimension + wall/floor thickness + 3" sleeve non-motor side • All dampers Wltfi EFL:br PFL ' _ . . S. Electric Acttaa Over 10". 10'r (254) Over 21" .21" (254), : 'High 811tlr (S33) i H)gh Under, , Hfgh Hlgf 11n t i(see~nctte) (see, 71/e" (181) 105/e" (270) 7f/8" (181) . 10s/e" Motor Side m-motor Side Note: See basic UL Installation Instructions for complete Installa- tion requirements, All dampers;with TS150 `or Sploo 'neuipa tic,A`ctua tors 331 4Q27(P.) Over 28 ' 33i 2961(D) 331c3060(F) 28 ;(711) (71"I:) High & ' Over D2" 3211( ei3) (813) HI 'h & g Over 40" 40" (1016). 6 High Under 1 (10.1 ) Hlgh,& H ugh' Urider High 'U ' 7Ue" (181) I We" (270) PH- (1 e1 105 " nder. 71/e" (181) 10s/s" (270) Note: The 21" (533) dimension becomes 32" (813) when the MS4120, MS8120, GGD221 or FSNF 120 are utilized. "Sleeve F Length Wait, 1n. 1 Floor 3" 11611n. Dimenaton -T,.•~ ~Slseve Io_ AMCA. LICENSED t_EAtiCAGE AND AIR PERFORMANCE DATA Ruskin Company certifies Wal, the FSD36 shown hereon is licensed to bear lilne AMCA Seal, The ttatings shOM lare.:based on-tests ;end proce- dures performed in accordance with AMCA Publication 511 and comply AIR with the requirements of the AMCA Certified Ratings Program. The AMCA Certified Ratings Seal applies to air performance for the FSD36, To determine the AMCA Licensed air performance; Locate the applicable feet per minute face velocity on the bottom of the velocity vs, pressure drop chart below. Move up the chart to the most appropriate size damper line. From the intersection point, move left to determine the pressure drop on the left side of the chart, For other damper sizes refer to Air Performance Data For All Fire and Smoke Dampers spec sheet VELOCITY vs. PRESSURE DROP 1 A 0 3 0.; W Z U z v 0 0.1 tY .09 .08 x .07 Cn .06 W .05 .04 .03 .D2 01 10 100 - a 1 Gy 2 3 4 6 7 89 SOD 1D00 5000 FACE VELOCITY- FEET/MINUTE 10000 AMCA Fig. 5.3 DIMENSIONAL INFORMATION 0-(152) Min. s• n. Min. 411002) Mtn; 17" (432) or 1 20" s0s) Min. 8or0+2" I (Bar D+51) A`or~0 ~rZ' (A or0+51) ROUND, OVAL OR RECTANGULAR DUCT TRANSITION CONNECTION FSD36 dampers supplied with round connections (R for low pressure, CR for medium pressure or WR welded for high pressure) are; Minimum 4" (1102) in diameter Maximum 94" (2388) in diameter The square size of the damper will be 2" (51) larger than the diameter dimension ordered. FS036 dampers suppged With rectangular connec- tions (C for low to medium pressure or WC welded for high pressure) are; M Maximum inimum 6"w x 4"h (152 x 102) Maximum horiz nltal 142"w8x 94"h (3607 2x 2388) The square size of the damper will be 2" (51) larger than the width and height of the damper A x B dimensions, FSD36 dampers supplied with oval connections (LO for low pressure, CO for medium pressure or WOant welded for high pressure) will be 2" (51) larger th he width and height of the damper A x B dimensions. MINIMUM SIZES Nominal - 8"W x 6"h (203 x 152). Actual - 7314"W X 53/4"h (197 x 146). Dampers with heights (B dimension) less than 6" (152) require Style B tran- sitions and a sleeve. The damper itself remains B" (152) high. SPECIFICATION Max. Height '"t MAXIMUM UL CLASSIFIED SIZE Single Section: 36"w x 48"h (914 X 1219) Multiple Section Assembly. Vertical Installation - 126"w x 96"h (3200 X 2438) or 72"wx 122"h (1829 x 3099) Horizontal Installation 144"W X 96"h (3658 x 2436) For dampers exceeding these dimensions consult Ruskin. Combination fire/smoke dampers meeting or exceeding- t-_ folow_ ing specifications shall be furnished and installed at locations shown on plans or as described In schedules. Dampers shall meet the requirements of NFPA90A, 92A and 928 and shall be clas for use for fire resistance ratings of Tess sified dance with UL than 3 hours, in accord Dampers In Dampers shall further be classifed as Smoke accord ance with the latest version of UL555S. The leakage rating under UL555S shag be leakage Class 2. In addition to the leakage ratings already specified herein, the dampers and their actuators shall be qualified under UL555S to an elevated temperature of 250"F (1210C) or 350"F (177"C) depending upon the actuator. Appropriate electrlc/pneumatic actuators (specl- (ler select one) shall be Installed by the damper manufacturer at time of damper fabrication. Electric actuators shall have been ener- gized hold open tested for a period of at least 1 year with no spring return failures. Damper and actuator shall be supplied as a single entity which meets all applicable UL555 and UL555S qualifications for both dampers and actuators. Each damper shall be rated for leakage and airflow in either direction through the damper. Eaontchrocollmbedcinlosuatfon fire/smoke damper shall be equipped with a "cre" quick detect heat actuated release device to duct am prevenlosuretIs unacceptable component damage, Instantaneous damper Damper frame shall be minimum 16 0.6) gage galvanized steel formed into a structural hat channel reinforced at comers. Damper blades shall be single skin galvanized steel 16 (1.6) gage minimum with three longitudinal grooves for reinforcement. Bearings shall be stainless steel sleeve turning in an extruded hole in the frame. Blade edge seals shall be inflatable silicone coated fiberglass and galva_ nizad steel mechanically locked Into blade edge (adhesive or clip on seals not acceptable). Jamb seals shall be stainless sleel compres- sion type. Each damper shall be supplied with a factory mounted sleeve of 17" (432) minimum length. Dampers shall be Ruskin model FSD36. (Consult Ruskin for detailed CSI Masterrorrnal Specification). EO 3900 Or. Grooves Rd. ® Kansas City, MO 64030 761 665 7 (881616) 765-7476 RUS-MIN. FAX fats► 5-8955 WWW.Mukln.com z) 8-(203) Mtn. Min.