Loading...
HomeMy WebLinkAboutDRB110045 approved plans DN UP UP L L N N M P E D FP NEED TO AS-BUILT, LOOKING FOR DRAWINGS FROM TOWN 110 UNIT /J 109 UNIT /I 108 UNIT /H 111 UNIT /K VAIL BOOT & SHOE SECRET GARDEN ANNIE'S MECHANICAL ROOM ELEC COMMON PARKING GARAGE 2 A6.1 16' -5 7/8" 23' -10 3/8" STAIR TOWER NEW FOUNDATION GREASE INTERCEPTOR 5 A6.4 NEW SHED ROOF NEW MECH CHIMNEY NEW MECH CHIMNEY NEW MECH CHIMNEY (INSIDE OF EXISTING TOWER) 1 3 4 5 7 8 10 11 2 A6.1 RIDGE RIDGE RIDGE 5" /1'-0" 5" /1'-0" 5" /1'-0" 5" /1'-0" 5" /1'-0" 5" /1'-0" 5" /1'-0" 5" /1 '-0" 5 " /1'-0" 5 A6.4 EXISTING WALL BELOW CANTILEVERED PLATFORM EXISTING FAN CANTILEVERED PLATFORM NEW CHIMNEY WALL EXIST WALL BELOW MECH FAN RE: MECH DWGS. NEW LADDER TO MEET FIRE DEPT. REGS. 42" HEIGHT GUARDRAIL EAST CHIMNEY SCREEN W/METAL MESH FOR AIR-FLOW MECH SHED ROOF BELOW DRAINAGE CRICKET BELOW LADDER IN TOWER -FLOOR OPENING SOUTH CHIMNEY 2 HIBACHI VENT FANS NEW LADDER TO MEET FIRE DEPT REGS. W.P. CRICKET 42" HEIGHT GUARDRAIL EXISTING FAN EXISTING FAN NORTH CHIMNEYLADDER SHAFT -OPEN AIR 4 HIBACHI VENT FANS 4' -0" 4' -0" 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanle yarchitects.com Project number Date MECHANICAL ENGINEER: KEENAN CONSULTING GROUP 2174 SOUTH BROADWAY DENVER, CO. 80210 P (303)282-9411 keenancg@keenancg.com REVISIONS ELECTRICAL ENGINEER: HUTCHINSON-PAPESH 13986 W. BOWLES AVE 102 LITTLETON, CO. 80127 P (303)973-9779 brent@hutchengineering.com STRUCTURAL ENGINEER: KRM CONSULTANTS, INC PO BOX 4572 VAIL, CO. 81658 P (970)949-9391 tdh@krmconsultants.com FIRE SPRINKLERS /ALARM: WESTERN STATES FIRE PROTECTION -JOE HAYDEN 274 CENTER DR. GLENWOOD SPRINGS, 80601 P (303)549-8979 joe.hayden@wsfp.us 3/3 /2011 10:22:32 AM V ILLAGE INN PLAZA -COMMERCIAL LEVEL 2 68 E AST MEADOW DRIVE UNIT 60 2 LOT O,5D,FILING 1 A2.2 LOWER, UPPER, AND ROOF PLANS 0410 WOO RESTAURANT 09-16-2010 MR. RICK WOO -OWNER 1" = 10'-0" 2 LOWER LEVEL PLAN 1" = 10'-0" 3 UPPER LEVEL 1/8" = 1'-0" 1 ROOF PLAN 1 No. Description Date 2 Revision 2 9-16-10 6 Revision 6 12-1-10 9 Revision 9 3-1-11 2 6 9 MAIN LEVEL 0" LOWER LEVEL -10' -0" UPPER LEVEL 10' -0" LOFT LEVEL 19' -4" ROOF PLAN 1 20' -0" NEW MECHANICAL EQUIPMENT LOCATED WITHIN EXISTING TOWER. NEW BANNER SIGNAGE 16' X 1'-2" = 18.5 SQ. FT. NEW WALL SIGNAGE 30 SQ. FT. 15 14 13 12 NEW WINDOWS MAIN LEVEL 0" LOWER LEVEL -10' -0" UPPER LEVEL 10' -0" LOFT LEVEL 19' -4" ROOF PLAN 1 20' -0" EXISTING BRIDGE NEW CHIMNEY FOR KITCHEN HOOD EXHAUST NEW MECH. SHED CLASS "A" COMPOSITE SHINGLE ROOF TO MATCH EXISTING. WOOD SIDING TO MATCH EXISTING STUCCO TO MATCH EXISTING NEW SERVICE DOOR MECHANICAL LOUVER GRILL PAINT TO MATCH WOOD ACCESS PLATFORM EXISTING PARKING GARAGE EXISTING STOREFRONT WINDOWS TO REMAIN REMOVE STOREFRONT WINDOW AND DOOR 7' -0" NEW MECH CHIMNEY STUCCO TO MATCH TWO EXHAUST DUCTS PROTRUDING FROM EXISTING TOWER MAIN LEVEL 0" LOWER LEVEL -10' -0" UPPER LEVEL 10' -0" LOFT LEVEL 19' -4" ROOF PLAN 1 20' -0" NEW CHIMNEY CONSTRUCTION NEW SHED EXTENSION NEW CHIMNEY BRIDGE NEW EXHAUST FAN STUCCO TO MATCH EXISTING STUCCO TO MATCH EXISTING WOOD SIDING TO MATCH MATCH METAL ROOF -DARK BROWN METAL MESH SCREENLADDER ENTRY MAIN LEVEL 0" LOWER LEVEL -10' -0" UPPER LEVEL 10' -0" ROOF PLAN 1 20' -0" NEW MECHANICAL CHIMNEY NEW MECH EQUIPMENT PLATFORM (INSIDE OF EXIST TOWER) EXISTING ENTRY DOOR TO REMAIN NEW EXHAUST FAN BEYOND STUCCO TO MATCH EXISTING EXISTING BRIDGE NEW BANNER SIGNAGE 16' X 1'-2" = 18.5 SQ. FT. 2 EXHAUST DUCTS PROTRUDING FROM WALL OF EXISTING TOWER 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanle yarchitects.com Project number Date MECHANICAL ENGINEER: KEENAN CONSULTING GROUP 2174 SOUTH BROADWAY DENVER, CO. 80210 P (303)282-9411 keenancg@keenancg.com REVISIONS ELECTRICAL ENGINEER: HUTCHINSON-PAPESH 13986 W. BOWLES AVE 102 LITTLETON, CO. 80127 P (303)973-9779 brent@hutchengineering.com STRUCTURAL ENGINEER: KRM CONSULTANTS, INC PO BOX 4572 VAIL, CO. 81658 P (970)949-9391 tdh@krmconsultants.com FIRE SPRINKLERS /ALARM: WESTERN STATES FIRE PROTECTION -JOE HAYDEN 274 CENTER DR. GLENWOOD SPRINGS, 80601 P (303)549-8979 joe.hayden@wsfp.us 3/3 /2011 2011 10:22:42 AM V ILLAGE INN PLAZA -COMMERCIAL LEVEL 2 68 E AST MEADOW DRIVE UNIT 60 2 LOT O,5D,FILING 1 A4.1 EXTERIOR ELEVATIONS 0410 WOO RESTAURANT 09-16-2010 MR. RICK WOO -OWNER 1/8" = 1'-0" 1 South 1/8" = 1'-0" 2 North 1/8" = 1'-0" 3 East 1/8" = 1'-0" 4 West No. Description Date 1 Revision 1 9-2-10 2 Revision 2 9-16-10 3 Revision 3 10-18-10 6 Revision 6 12-1-10 9 Revision 9 3-1-11 2 1 2 6 1 1 3 9 9 MAIN LEVEL 0" LOWER LEVEL -10' -0" UPPER LEVEL 10' -0" ROOF PLAN 1 20' -0" UPPER LEVEL RESIDENTIAL APARTMENT MECHANICAL ROOM PARKING A SECRET GARDEN RETAIL SHOP SUSHI BAR LIQUOR BAR STAIR NEW IN-LINE EXHAUST FANS TOWER CREATE NEW OPENINGS IN EXISTING WALL NEW MECH CHIMNEY WITH SLOPED ROOF TOP OPEN TO ROOF SIDE NEW IN-LINE EXHAUST FANS NEW MECH PLATFORM STEEL GRATE ATTACHED TO CANTILEVERED STRUCTURAL TEES. MAKE REMOVABLE FOR SNOW CLEAN-UP BELOW EXISTING FAN HIBACHI TABLE 10" 1' -11 5/8" PRIVATE STAIRS FROM LOWER LEVEL TO MAIN LEVEL DOOR BEYOND UPPER LEVEL RESIDENTIAL APARTMENT 8' -2 7/8" 8' -2 7/8" NEW DROPPED CEILING INSIDE OF STAIR TOWER NEW STUCCO CEILING STRUCTURAL ENGINEER TO VERIFY OPENING IN STEEL BEAM FOR PLUMBING AND WASTE LINE PASS-THRU NOTE: PLUMBING TO BE TRENCHED FROM CONCRETE FLOOR ABOVE. RETAIL CEILING TO REMAIN UNDISTURBED. BAR SINK BEYOND DROPPED CEILING BEYOND NEW DROPPED CEILING FOR MECHANICAL DUCTS NEW DROPPED CEILING FOR HIBACHI DUCTS NEW CHIMNEY FOR HIBACHI DUCTS NEW MECHANICAL DUCTS WITHIN EXISTING JOIST SPACE EXISTING DRYWALL CEILING TO BE REMOVED. NEW DRYWALL CEILING -3" HIGHER (VERIFY) C EILING HEIGHT 1 A5.2 APPROX LOCATION OF EXISTING SEWER DRAIN GREASE INTERCEPTOR METAL ROOF CRICKET SLOPE 2" /12" 8" 8' -2 7/8" A6.3 1 2 A6.2 A6.3 1 Sim 9" 7 7/8" 9" 5 A2.3 5" 1'-0" NEW 42" GUARDRAIL, EXTEND 30" BEYOND PLATFORM 4 A6.3 5 A6.3 2 A6.5 7 A6.2 UNFINISHED AREA DUCT WITH FIREINSULATION WRAP DUCT WITH FIRE -INSULATION WRAP EXISTING PLATFORM MIDDLE BEAM TO BE MOVED TO PROVIDE OPENING FOR LADDER ACCESS 2' -6 3/4" 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanle yarchitects.com Project number Date MECHANICAL ENGINEER: KEENAN CONSULTING GROUP 2174 SOUTH BROADWAY DENVER, CO. 80210 P (303)282-9411 keenancg@keenancg.com REVISIONS ELECTRICAL ENGINEER: HUTCHINSON-PAPESH 13986 W. BOWLES AVE 102 LITTLETON, CO. 80127 P (303)973-9779 brent@hutchengineering.com STRUCTURAL ENGINEER: KRM CONSULTANTS, INC PO BOX 4572 VAIL, CO. 81658 P (970)949-9391 tdh@krmconsultants.com FIRE SPRINKLERS /ALARM: WESTERN STATES FIRE PROTECTION -JOE HAYDEN 274 CENTER DR. GLENWOOD SPRINGS, 80601 P (303)549-8979 joe.hayden@wsfp.us 3/3 /2011 10:22:46 AM V ILLAGE INN PLAZA -COMMERCIAL LEVEL 2 68 E AST MEADOW DRIVE UNIT 60 2 LOT O,5D,FILING 1 A5.1 BUILDING SECTION0410 WOO RESTAURANT 09-16-2010 MR. RICK WOO -OWNER 3/8" = 1'-0" 1 BUILDING SECTION 1 No. Description Date 7 Revision 7 12-21-10 9 Revision 9 3-1-11 7 7 7 9 DN UP MAIN LEVEL 0" LOWER LEVEL -10' -0" UPPER LEVEL 10' -0" LOFT LEVEL 19' -4" 3 A6.5 ACCESS LADDER TO MEET T.O.VAIL FIRE REGS. HIBACHI DUCT -1-HR RATED WITH "FYREWRAP" ELITE 1.5 DUCT INSULATION EXISTING STUCCO TOWER 6' -6" 42" HEIGHT GUARDRAIL 3'0" X 4'-0" OPENING IN FLOOR EXISTING TOWER CLEAN-OUTS, ACCESS PANELS AND PLATFORM -SEE NORTH TOWER DETAILS -SIMILAR 3' -0" MECH FANS TO PROTRUDE THROUGH OPENINGS IN EXISTING WALL. CAULK TO WATERPROOF. EXISTING PLATFORM NO FINISH INSIDE OF EXISTING TOWER STUCCO RE-FINISH AND REPAIR 15' -0" CONTRACTOR TO VERIFY NEW PLATFORM CHASE SPACE FOR FIRE-WRAPPED HIBACHI DUCTS 7' -0" 7' -0" HATCH IN CEILING NEW CEILIING -STUCCO FINISH FLOOR HATCH TO HINGE AND COVER OPENING. ROOF PLAN 1 20' -0" 1 A6.5 ROOF PLAN 36' -0" 1 A6.5 1 A6.5 3 A6.5 2 A6.5 3' -5" 4' -0" LADDER SHAFT 3' -0" 2' -8" 1' -6 1/8" 42" HEIGHT EXISTING FLOOR PLATFORM GUARDRAIL 1' -3" 0" 2' -6" 11" EXISTING BEAM TO BE MOVED APPROX. 1'6" TO EAST TO MAKE ROOM FOR LADDER OPENING CLEAN-OUTS -FLOOR GRATE (SHOWN GREY) TO DROP DOWN ON HINGE TO COVER OPENING. FAN UNIT MECHANICAL ACCESSIBILITY LADDER MAIN LEVEL 0" LOWER LEVEL -10' -0" UPPER LEVEL 10' -0" 7' -0" 6' -8" 7' -0" HEAD HT. 8' -3 3/4" HEAD HT. 3' -6" EXIST LANDING TO NEW PLA TFORM NEW PLATFORM TO NEW CEILING EXTEND EXISTING 20" X 20" CENTER POST STAIN TO MATCH 42" HEIGHT GUARDRAIL 7 RISERS 11.43" EACH ATTACH LADDER TO WALL JUST ABOVE PLATFORM HATCH BEYOND NEW CEILING 5/8" GWB ON 2X6 MTL STUDS PATCH ALL WALLS WITH STUCCO TO MATCH EXIST 6' HEIGHT METAL GATE WITH LOCK 7' -8" 7' -9" NEW METAL GRATE PLATFORM STRUCTURE W/1"X3" MTL CHANNELS NEW METAL GRATE STAIRS STRUCTURE W/1"X3" MTL CHANNELS BOLT TO BLOCKING IN EXTERIOR WALL BOLT TO CENTER WOOD POST STAIR FOR SERVICE AND FIRE ACCESS ONLY, NO PUBLIC ACCESS 42" HEIGHT GUARDRAIL 7 RISERS, 11.43" HEIGHT ACCESS LADDER TO MEET VAIL FIRE REGS. MAIN LEVEL 0" 6' -0" 3' -0" NEW WROUGHT IRON GATE W/LOCK NEW CENTER POST EXTENSION EXIST LANDING 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanle yarchitects.com Project number Date MECHANICAL ENGINEER: KEENAN CONSULTING GROUP 2174 SOUTH BROADWAY DENVER, CO. 80210 P (303)282-9411 keenancg@keenancg.com REVISIONS ELECTRICAL ENGINEER: HUTCHINSON-PAPESH 13986 W. BOWLES AVE 102 LITTLETON, CO. 80127 P (303)973-9779 brent@hutchengineering.com STRUCTURAL ENGINEER: KRM CONSULTANTS, INC PO BOX 4572 VAIL, CO. 81658 P (970)949-9391 tdh@krmconsultants.com FIRE SPRINKLERS /ALARM: WESTERN STATES FIRE PROTECTION -JOE HAYDEN 274 CENTER DR. GLENWOOD SPRINGS, 80601 P (303)549-8979 joe.hayden@wsfp.us 3/3 /2011 10:22:55 AM V ILLAGE INN PLAZA -COMMERCIAL LEVEL 2 68 E AST MEADOW DRIVE UNIT 60 2 LOT O,5D,FILING 1 A6.5 SOUTH TOWER DETAILS 0410 WOO RESTAURANT 09-16-2010 MR. RICK WOO -OWNER No. Description Date 7 Revision 7 12-21-10 8 Revision 8 2-10-11 9 Revision 9 3-1-11 1/4" = 1'-0" 1 SOUTH TOWER SECTION 1 1/2" = 1'-0" 2 SOUTH TOWER SECTION 3 1/4" = 1'-0" 3 SOUTH TOWER SECTON 2 1/2" = 1'-0" 4 SOUTH TOWER PLAN 5 SOUTH TOWER VIEW 3D 7 1/2" = 1'-0" 7 PLAN -SOUTH TOWER -MAIN 1/2" = 1'-0" 8 SOUTH TOWER SECTION 4.5 8 8 9 9 9 9 8 9