HomeMy WebLinkAboutDRB110065Department of Community Development
75 South Frontage Road
Vail, Colorado 81657
I }W OF VAIL►
t
Tel: 970 - 479 -2128.
44- Fax: 970 -479 -2452
Web: www.vailgov.com
Development Review Coordinator
v -.
Application for Design Review
Conceptual Review
General Information: A conceptual review may be requested by an applicant where new construction or major
changes are to occur on a property. A conceptual review does not serve as a final approval and an additional applica-
tion is required for final review. The conceptual review is intended to allow the applicant to introduce the project to the
Design Review Board and receive comments. The DRB does not vote on conceptual reviews.
Fee: $0
Single Family Duplex Multi - Family Commercial
Description of the Request: New duplex home and associated site improvements proposed on Lot 7. Existing
house, existing detached 2nd unit and existing nonconforming deck in rear setback /extending past south property
line to be demolished.
Physical Address: 232 West Meadow Drive, Vail, CO 81657 (lot 7, Vail Village Filing 2)
Parcel Number: 2101- 071 -01 -0 (Contact Eagle Co. Assessor at 970 - 328 -8640 for parcel no.)
Property Owner: Mery Lapin
Mailing Address: 2 West Meadow Drive, Vail, CO 81657
Owner's Signature:
1
Primary Contact/ Owner Representative:
Hans Berg o f Be rglund Ar LLC
Mailing Address: P.O. Box 2378, Edwards, C 81632
E -Mail: hans @berglundarchitects.com
Fax: 970.926.4364
For Office Use Only: Cash_ CC: Visa / MC Last 4 CC # Auth #
Fee Paid: Waived Received From:
Meeting Date: DRB No.:
Planner:
Zoning:
Project No: `m /I ' 00 -- )
Land Use: 11111 UK
Location of the Proposal: Lot: Block: Subdivision:
Check #
Phone: 970.471.6001
Phone: 970.926.4301
01- Jan -10
BERGLUND ARCHITECTS
3/9/2011
Lapin / Coffey Residence
Lot - 232 West Meadow Drive, Vail Village Filing 2, Lot 7
Zone District: 2 family residential ( R)
Lot is .672 acres, equal to 29,277 SF
Allowable GFRA
.46 SF /1 SFof site area < 10,000 SF of site area
.38 SF per 1 SF of site area > 10,000 SF of site area 10,000 x 0.46 equals 4,600 SF
5,000 x 0.38 equals 1,900 SF
.13 SF per 1 SF of site area > 10,000 SF of site area
Total Allowed Gross Residential Floor Area (GRFA) for entire lot 14,277 x 0.13 equals 1,856 SF
8,356 SF
Allowable site coverage is 20% of lot
5,855 SF
Square Footage Summary
Lower Level
Main Level
Upper Level
Garage over 600 SF
Primary Unit Garage
Secondary Unit Garage
Site Coverage
GRFA
Primary Unit - Main Level Habitable w/o Merv's office
Merv's Office
Secondary Unit - Main Level Stairs
Upper Level - Primary Unit Habitable
Upper Level - Seconary Unit Habitable
Habitable SF
GRFA SF
2,405.0 SF
96.0 SF *2
4,542.0 SF
4,542.0 SF
3,215.0 SF
3,605.0 SF
SF
80.0 SF *1
10,162.0 SF
8,323.0 F
Provided SF
Allowed SF
680.0 SF *1
600.0 SF
480.0 SF
600.0 SF
5,816.5 SF
5,855.0 SF
8,323.0 SF
8,356.0 SF
3,569.0 SF
822.0 SF
151.0 SF
1,654.0 SF
1,561.0 SF
*1 80 SF of Garage Area over the allowable 600 SF is shown in the GRFA calculation
*2 4.0% of the Lower Level wall is above existing grade therefore 4.0% of the Lower Level SF is counted as GRFA.
BERGLUND Architects, LLC TRANSMITTAL
DATE March 17, 2011
TO Town of Vail
Department of Community Development
75 South Frontage Road
Vail, CO 81657
970.479.2128
970.479.2452 Fax
C.C.
C.C.
FROM Hans Berglund
RE 232 West Meadow Drive Residence; Vail Village Filing 2, Lot 7
VIA Hand Delivery
ENCLOSED (1) Application for Conceptual Design Review New Construction
(3) Sets of 30x42 drawings for Conceptual Design Review New Construction
(1) Exhibit for Final Plat 24x36 sheet showing proposed lot modification per
P &Z final plat approval.
(1) rendered elevation 2436 sheet
(6) exterior perspective drawings
*note: Once the snow melts the owner intends to change the driveway on Lot
6 as agreed upon by P &Z and then record the approved Final plat with lot
modification as show in the included exhibit.
COMMENTS The existing home is proposed to be torn down.
New home proposed Materials:
1) Low Slope Roofing - Copper standing seam
2) Steeper Roofing - Synthetic shake.
3) Typical 2x8 Fascia and 6x10 Rafter tails with light brown stain
4) Dry stacked brownish sandstone stone veneer with steel C- channel
window headers
5) Medium brown patina Copper siding panels.
6) Typical 4' roof eave - steel w- section beam @ eave with 6x8 timber
struts
7) Gate to be patina steel frame with horizontal copper panels
*a more preliminary conceptual color was include to show diagrammatic
colors. Black and white elevations are more accurate.
Thank you very much.
Hans Berglund
P.O. Box 2378, Edwards, CO 81632
Tel: 970 926 -4301 fax: 970 926 -4364
Bill Gibson
From: Bill Gibson
Sent: Friday, April 01, 20113:47 PM
To: Hans Berglund
Subject: Lapin Residence (DRB110065)
Hey Hans,
The Town of Vail has reviewed the conceptual design review application for a new two - family residence at 232 West
Meadow Drive. The following is a summary of the preliminary comments from that review:
• The subdivision plat amending the property boundaries between Lots 6 and 7 must be executed prior to
application for final design review.
• Reconstruction of the neighboring Lot 6 driveway must be submitted as a separate design review
application. The reconstructed driveway must be a minimum of 12 feet wide.
• The final design review application must include all plan details and supplemental materials identified on the
application form.
• New easements associated with the subdivision plat must be shown on the survey and site plans.
• A demolition plan and revegetation plan must be submitted for the removal of the existing bridge located on the
adjacent Town of Vail owned Gore Creek stream tract.
• Fire sprinklers and monitored alarm systems will be required.
• The topographic survey must be stamped, delineate the current FEMA adopted Gore Creek 100 -year flood plain,
delineate any existing wetlands, and accurately identify the center line of Gore Creek (the shown center line
does not appear to consider the channel of the creek located under the existing bridge).
• A delineation report by a qualified environmental consultant must be submitted for any wetlands.
• Pursuant to Section 14 -10 -9, Vail Town Code, "fences shall not be encouraged except to screen trash areas,
utility equipment, etc."
• A tree removal and tree preservation plan must be submitted for review.
• Limits of disturbance, erosion control, and BMP plans must be submitted for review.
• The new eastern driveway must be shifted west to no be located in front of Lot 5.
• A four foot concrete pan will be required between the driveways and the West Meadow Drive edge of asphalt.
• A Revocable Right -of -Way Permit will be required for all improvements in the West Meadow Drive right -of -way.
• Any boulder retaining walls constructed with more than one course of stones will require stamped engineering
drawings.
• Prior to building permit submittal, verify that all proposed chimneys meet minimum heights and clearances.
This proposal has been scheduled for a conceptual review before the Town of Vail Design Review Board at its
Wednesday, April 6 t " public hearing beginning at 3:00pm in the Town Council Chambers.
Please feel free to contact me directly via email or at 479 -2173 if you have any questions.
Sincerely,
Bill
Bill Gibson, AICP
Town Planner
Community Development Department
Tox►+1TrAU.�
Direct 970 - 479 -2173
Fax 970 - 479 -2452
hap: / /www.vail og v.com
9 ?Fl.;psoJoin mR inmaking#jliftro",IW' kWfore
PLANNING CHECK SHEET
Property Information
Property Address
232 West Meadow Drive
Parcel #
210107101004
Legal Description
Lot 7, Vail Village Filing 2
Development Site Area
Ac
0.672
pending new plat
Sq Ft
29,277
Buildable
n/a
Zoning / SDD #
Two - Family Primary /Secondary
Land Use Designation
Medium Density Residential
Known Non - Conformities
n/a
Previous Approvals
n/a
Hazard Zones
Sections 12 -12, 12 -21, 14 -6 & 14 -7
Snow Avalanche
n/a
Debris Flow
n/a
Rockfall
n/a
Excessive Slopes
(Site Disturbance 12- 21 -14)
n/a
Floodplain
Gore Creek
Wetlands Y/N
?
Creeks, Streams
Section 12 -14 -17
Setback
50
Proposed
50+
Sidewalks/ Trails
n/a
Contact Information
Planner/ Date
BG 4/6/11
Owner Contact Info
Mery Lapin, 471 -6001
Primary Contact/ Owner
Representative Info
Hans Berglund, Architect, 926 -4301
Project Information
Project Description
CONCEPTUAL New Duplex
Land Use Application(s) #
DRB 110065
Proposed Uses
(As defined by Zoning)
duplex
Permitted, Conditional,
Prohibited?
permitted
Date Routed/ DRT Meeting
3/23/11
Commercial Floor Area
Existing
n/a
Proposed
n/a
Gross Residential Floor Area (Chapter 15)
Total
Allowed
8,356
-
Existing
demo
- Proposed
8,323
Primary
n/a
-
Existing
demo
- Proposed
6,688
Secondary
3,342
-
Existing
demo
- Proposed
1,635
Total
Remaining
35
Primary Total
Remaining
n/a
Secondary Total
Remaining
n/a
250 or Interior Conversion?
n/a
Zoning District Standards
Setbacks (perimeter)
Projections 14 -10 -4
Front
20
Proposed
Y
Side
15115
Proposed
Y/Y
Rear
15
Proposed
Y
Minimum Lot Area/ Width
Required
15,000
Proposed
pending new plat
Site Coverage
20% Allowed
5,855
Proposed
5,817(20%)
Building Height
Allowed
30/33
Proposed
Y
Landscaping
Sections 14 -10 -8 & 14 -10 -9
60% Required
17,566
Proposed
19,050 (65 %)
Plant size
6', 2 ", 5 gal.
Proposed
?
Fences
n/a
Proposed
?
Retaining Walls
Sec. 14-6-7
Height Allowed
6
Proposed
?
Setback
2
Proposed
?
Driveway
Sections 14 -3 -1 & 14 -3 -2
Max Curb -cuts
48
Proposed
?
Max Slope
12%
Proposed
?
Min Width
12 min
Proposed
?
Heated Y/N
Y
Drive Material
?
Snow Storage %
10%
Proposed
?
Parking
Sections 12 -10 & 14 -5
Spaces Required
7
Proposed
?
Loading
n/a
Proposed
?
Lighting
Section 14 -10 -7
Allowed
29
Proposed
?
Waste Management
Section 5 -9
Wildlife Proof/
Resistant
n/a
Screened
?
Screening
Sections 14 -10 -9 & 14 -10 -10
Required
Y
Proposed
?
Roof Material
Sections 12 -11 -3C & 14 -10 -5
Complies Y/N
Y
Building Separation
Section 14 -10 -6
Complies Y/N
n/a
Adopted View Corridors
Complies Y/N
n/a
Utilities
(Location, easements)
Section 14 -10 -10
n/a
Grading (Less than 2:1)
Section 14 -6
?
Development Impact Fees /
Mitigation
Employee Housing
n/a
Traffic Impact
n/a
Art In Public Places
n/a
Notes
CONCEPTUAL REVIEW ONLY
Some data is ? pending final submittal plans.
Associated minor subdivision plat must be executed prior to final design
review application.