B11-0045
THUNDER MOUNTAIN TESTING ®0� 2973 F. Road ♦ Grand Junction, CO 81504 (970) 256 -9965 / Cell (970) 210 -7008 / FAX (970) 314 -7067 [E OCT n 3 2U11 TOWN OF VAIL Nedbo Construction August 15, 2011 P.O. Box 3419 Vail Colorado 81658 ATTN: Mr. Mark Stevenson RE: The Tyrolean -Unit #7 Remodel Permit #B 11 -0045 400 East Meadow Drive Vail, Colorado 81657 Dear Mr. Stevenson, As requested, structural steel special inspection was conducted at the above referenced project per the IBC 2009 Edition - Chapter 17: Structural Tests and Special Inspection and the Town of Vail requirements. i arrived on site at 10:30 AM. I met with you on site to review areas ready for inspection. Prior to my arrival this week you contacted me regarding inspection requirements implemented my Ms. Kith McGee with KRM Consultants, Inc. for the non - inspected CJP groove welds as referenced in my 9 -6- 11 report. Ultrasonic welding inspection shall be conducted on all 4 splices on site for further examination of the CJP groove welds per AWS D 1.1: Structural Welding Code — Steel. Ultrasonic inspection was conducted on 4 each CJP groove welded connections as referenced in my 9 -6 -11 report. Inspection began utilizing a Krautkramer USK -6 Ultrasonic Instrument with a KB Aerotech .75 X .75 Diameter transducer (SIN 032KTF) with an approved 700 probe. Calibration and sensitivity levels were set on an AWS DSC Block with a 10" screen range. The sensitivity level was set at 80% full screen height. Scanning was conducted at approximately 15 -20 Db over the sensitivity level. The Upper Roof bent beam single splice CJP groove weld was inspected on both flanges and web. No unacceptable indications were observed during inspection. The 3 CJP groove welded splices above the South window were inspected and all three were observed to have rejectable indications in various flange and web locations. During inspection I observed the following unacceptable fabrication conditions: 1) All beam access holes were torch cut without grinding the radius surfaces to provide a notch free area as required, 2) The center CJP groove weld at the top flange to web "k" area was observed to have 2 gouges that were evident to be thru the web that were un- repaired, 3) The center CJP groove weld at the web: The weld was stopped short approximately I/," of its total length, and 4) The far left CJP groove weld's top flange has un- repaired grinding mark gouges measured to be approximately 1/8" deep by 1 ' /Z" long. Upon completion I contacted Ms. Kim McGee to inform her of the unacceptable welding conditions observed. She is in process of re- engineering repair procedures and additional beam reinforcement plates for installation. Continued inspection shall be conducted on 9- 19 -11. Resp° 'fully Submitted, Sc . Maxwe AWS CWI 991040201 ICC Certified #0863569 -S 1 & S2 Thunder Mountain Testing $C(il ( L MAXWE N 41040101 OC1 EXP.04J01112 Reviewed by: Michael Allan State of Colora THUNDER MOUNTAIN TESTING 2973 F. Road ♦ Grand Junction, CO 81504 (970) 256 -9965 / Cell (970) 210 -7008 / FAX (970) 314 -7067 OCT 0 3 2011 TOWN OF VAIL Nedbo Construction August 6, 2011 P.O. Box 3419 Vail, Colorado 81658 ATTN: Mr. Mark Stevenson RE: The Tyrolean -Unit 97 Remodel Permit #B 11 -0045 400 East Meadow Drive Vail, Colorado 81657 Dear Mr. Stevenson, As requested; structural steel special inspection was conducted at the above referenced project per the IBC 2009 Edition - Chapter 17: Structural Tests and Special Inspection and the Town of Vail requirements. I arrived on site at 11:30 AM. I met with you on site to review project requirements and specifications. The steel fabricator and erector for this project is Vail Manufacturing, Inc. in Vail, Colorado. The welder qualification test reports for the welder on site was reviewed and observed to be acceptable with project specifications. Copies of test reports are on file with you. Visual welding inspection was conducted at the Upper Level Floor Framing Plan on the column to beam and beam to beam fillet welded connections as required on Sheet S2: Details 1, 2, 4 & 5 on approved project drawings provide by KRM Consultants, Inc. in Vail, CO: Project # 1010 -06 dated 6- 10 -11. Inspection was conducted on welded material on entire level. All fillet welded connections referenced were observed to be as detailed and in compliance with project specifications. Visual inspection was conducted at the Upper Level Floor Framing Plan on the 3/4" ASTM A325 High Strength beam to beam and beam to column bolted connections. All bolted connections were inspected for "snug tight' ' tension requirements as referenced in the AISC: Manual of Steel Construction and Chapter 17 of the IBC: Table 1704.3 for Periodic Inspection requirements. Inspection was conducted on all bolts. Bolts were observed to be adequately tensioned to a snug tight condition. During my inspection on site I observed two fabricated bent beams that have a total of 4 each Complete Joint Penetration (CJP) groove welds that were not continuously inspected by an approved inspector during the fabrication process as required per Chapter 17: Table 1704.3, Item 5.a.1. I then contacted the project structural engineer Ms. Kim McGee with KRM Consultants, Inc. for inspection recommendations. She informed me that further consideration of this matter is needed prior to implementing an alternative inspection on site. Continued inspection shall be conducted at a later date. .o Respectfully Submitted, Reviewed by: • SCOTT L MAXWEL •� 9 1 Scott . axw 1 CNI 91040101 Michael Allan B 13dE. AWS CWI #91040201 QC1 EP,04101 /12 State ofColorad �OJ ft ICC Certified #0863569 -SI & S2 �? �fs•••Ne••� Thunder Mountain Testing /0NA � 8 MM NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES TOWN OF VAII ` Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11 -0045 Project #: PRJ11 -0019 Job Address: 400 E MEADOW DR VAIL Applied.....: 03/28/2011 Location......: TYROLEAN CONDOS UNIT 7 Issued...: 06/13/2011 Parcel No....: 210108252026 OWNER BLACK STALLION HOLDINGS INC 03/28/2011 791 CRANDON BLVD #807 KEY BISCAYNE FL 33149 APPLICANT BLACK STALLION HOLDINGS INC 03/28/2011 791 CRANDON BLVD #807 KEY BISCAYNE FL 33149 CONTRACTOR NEDBO CONSTRUCTION INC 03/28/2011 Phone: 970 - 845 -1001 PO BOX 3419 VAIL CO 81658 License: C000003087 Description: EXPAND UNIT BY ENCLOSING DECKS TO EAST. ADDITION WILL BE 15.5 FEET FROM PROPERTY LINE. Occupancy: R -2 Type Construction: VA Valuation: $363,000.00 * * * * * # + + # + * + + # * * * * * ** #****#****##**#**#***#****** * * * * * # * * * + * # * * * * * * * * * * * + # * * * + ++ FEE SUMMARY Building Permit ------ - - - - -> $2,466.55 Bldg Plan Check ----- - - - - -> $1,603.26 Use Tax Fee------------------ - - - - -> $7,060.00 Electrical Permit ---- - - - - -> $172.50 Elec Plan Check ------ - - - - -> $112.13 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $220.00 Mech Plan Check ---- - - - - -> $55.00 Additional Fees--------------- - - - - -> $6,016.25 Plumbing Permit --- - - - - -> $270.00 Plmb Plan Check ---- - - - - -> $67.50 Recreation Fee--------------- - - - - -> $250.00 Investigation------------------ - - - - -> $0.00 Will Call ------------------------------ > $20.00 TOTAL PERMIT FEES -- ----------- > $18,533.19 Payments -- ---------------------------- > $18,533.19 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and " sub codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. BREOQUUEEST FOOF Sr �L BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM Sig6aKre of Owner or Contractor Print Name combination permit_012811 o _7— Date OVkT0WN CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11 -0045 Address: 400 E MEADOW DR VAIL Owner: BLACK STALLION HOLDINGS INC Location: TYROLEAN CONDOS UNIT 7 #************************#****#**** k******# x*##** x# x***#***#******#*##*** x# x##**#*#**#*#*********** x* x* xx* x*#***** x***#******************#***********# # *x * * *xx # # *xx # #xxxxx #xxx # * * * * ** Cond: CON0011852 If any use of right of way is requried for staging or equipment, a Public Way Pemit application must be submitted to the TOV. combination permit_012811 TON OVAill REQUIRED INSPECTIONS AND STATUSES Permit #: B11 -0045 Address: 400 E MEADOW DR VAIL Owner: BLACK STALLION HOLDINGS INC Location: TYROLEAN CONDOS UNIT 7 Item: 00120 ELEC -Rough 05/26/2011 By: sgremmer Action: AP 05/31/2011 By: sgremmer Action: DN Comments: Need to see fuse size for AIC rating Item: 00200 MECH -Rough Item: 00224 FIRE -ALARM ROUGH Item: 00225 FIRE - SPRINKLER ROUGH Item: 00230 PLMB- Rough/Water Item: 00240 PLMB -Gas Piping Item: 00260 PLMB -Misc. Item: 00310 MECH- Heating Item: 00315 PLMB -Gas Piping Item: 00030 BLDG - Framing Item: 00050 BLDG - Insulation Item: 00410 Special Inspect - progress rept Item: 00060 BLDG - Sheetrock Nail Item: 00070 BLDG -Misc. Item: 00340 MECH -Misc. Item: 00190 ELEC -Final Item: 00290 PLMB -Final Item: 00390 MECH -Final Item: 00228 FIRE - Final Item: 00420 Special Inspect -final rept Item: 00534 PLAN - FINAL C/O Item: 00090 BLDG -Final combination permit_012811 TOWN OF VAIL, COLORADO Statement Statement Number: R110000638 Amount: $110.00 06/13/201104:09 PM Payment Method: Check Init: SAB Notation: 8024 mark stevenson ----------------------------------------------------------------------------- Permit No: Bll -0045 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 082 - 5202 -6 Site Address: 400 E MEADOW DR VAIL Location: TYROLEAN CONDOS UNIT 7 Total Fees: $18,533.19 This Payment: $110.00 Total ALL Pmts: $18,533.19 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 110.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADOCopy Reprinted on 01 -03 -2013 at 15:59:14 01/03/2013 Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R110000542 Amount: $110.00 05/25/201109:24 AM Payment Method: Check Init: SAB Notation: 16434 NEDBO ----------------------------------------------------------------------------- Permit No: Bll -0045 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 082 - 5202 -6 Site Address: 400 VAIL VALLEY DR VAIL Location: TYROLEAN CONDOS UNIT 7 Total Fees: $18,533.19 This Payment: $110.00 Total ALL Pmts: $18,533.19 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- 00100003111100, GFPO ELEC PERMIT FEES- GFP012 128.00 EP 00100003111100 ELECTRICAL PERMIT FEES - 128.00 PF 00100003112300 PLAN CHECK FEES 110.00 ----------------------------------------------------------------------- - - - - -- KRCONSULTANTS, INC. (970) J4J -93J1 FAX 949-1577 P.O. Box 4572 Vail, Colorado E31 BED TO:�^ n� � �JD l30 ATTENTION: PROJECT: ❑ MAIL LETTER OF TRANSMITTAL ❑ OVERNIGHT WE TRANSMIT HEREWITH THE FOLLOWING ITEMS: COPIES: DESCRIPTION: REMARKS: DATE: [PICK UP JOB NUMBER: Iniv- ❑ DELIVER COPY TO: SIGNED: WON -W�N NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MAI ov�Au Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: 1311 -0045 Job Address: 400 E MEADOW DR VAIL Location......: TYROLEAN CONDOS UNIT 7 Parcel No....: 210108252026 OWNER BLACK STALLION HOLDINGS INC 03/28/2011 791 CRANDON BLVD #807 KEY BISCAYNE FL 33149 APPLICANT BLACK STALLION HOLDINGS INC 03/28/2011 791 CRANDON BLVD #807 KEY BISCAYNE FL 33149 CONTRACTOR NEDBO CONSTRUCTION INC 03/28/2011 Phone: 970 - 845 -1001 PO BOX 3419 VAIL CO 81658 License: 0000003087 Description: EXPAND UNIT BY ENCLOSING DECKS TO EAST. ADDITION WILL BE 15.5 FEET FROM PROPERTY LINE. Project #: Applied.....: Issued... PRJ 11 -0019 03/28/2011 04/26/2011 Occupancy: R -2 Type Construction: VA Valuation: $363,000.00 .......................... .................. ........................ »<..,. FEE SUMMARY ...... ,..,... , .......,.,...........,.....,,.. ................,.............. Building Permit ------ - - - - -> $2,466.55 Bldg Plan Check ----- - - - - -> $1,603.26 Use Tax Fee------------------ - - - - -> $7,060.00 Electrical Permit ---- - - - - -> $172.50 Elec Plan Check ------ - - - - -> $112.13 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $220.00 Mech Plan Check ---- - - - - -> $55.00 Additional Fees--------------- - - - - -> $6,016.25 Plumbing Permit --- - - - - -> $270.00 Plmb Plan Check ---- - - - - -> $67.50 Recreation Fee--------------- - - - - -> $250.00 Investigation------------------ - - - - -> $0.00 Will Call ------------------------------ > $20.00 TOTAL PERMIT FEES -- ----------- > $18,313.19 Payments -- ---------------------------- > $18,313.19 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM -4. 0P Signature o ner ontractor Date Print Name combination permit_012811 CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: 611 -0045 Address: 400 E MEADOW DR VAIL Owner: BLACK STALLION HOLDINGS INC Location: TYROLEAN CONDOS UNIT 7 Cond: CON0011852 If any use of right of way is requried for staging or equipment, a Public Way Pemit application must be submitted to the TOV. combination permit_012811 tVFI'i1 Oki: REQUIRED INSPECTIONS AND STATUSES Permit #: 1311 -0045 Address: 400 E MEADOW DR VAIL Owner: BLACK STALLION HOLDINGS INC Location: TYROLEAN CONDOS UNIT 7 Item: 00120 ELEC -Rough Item: 00200 MECH -Rough Item: 00224 FIRE -ALARM ROUGH Item: 00225 FIRE - SPRINKLER ROUGH Item: 00230 PLMB- Rough/Water Item: 00240 PLMB -Gas Piping Item: 00260 PLMB -Misc. Item: 00310 MECH- Heating Item: 00315 PLMB -Gas Piping Item: 00030 BLDG - Framing Item: 00050 BLDG - Insulation Item: 00410 Special Inspect - progress rept Item: 00060 BLDG - Sheetrock Nail Item: 00070 BLDG -Misc. Item: 00340 MECH -Misc. Item: 00190 ELEC -Final Item: 00290 PLMB -Final Item: 00390 MECH -Final Item: 00228 FIRE - Final Item: 00420 Special Inspect -final rept Item: 00534 PLAN - FINAL C/O Item: 00090 BLDG -Final combination permit_012811 TOWN OF VAIL, COLORADO Statement Statement Number: 8110000354 Amount: $16,709.9304/26 /201103:00 PM Payment Method: Check Init: SAB Notation: 40136 NEDBO CONSTRUCTION ----------------------------------------------------------------------------- Permit No: Bll -0045 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 082 - 5202 -6 Site Address: 400 E MEADOW DR VAIL Location: TYROLEAN CONDOS UNIT 7 Total Fees: $18,313.19 This Payment: $16,709.93 Total ALL Pmts: $18,313.19 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- 11000003113300, CHPO HOUSING FEE IN LIEU ------ - - - - -- 6,016.25 BP 00100003111100 BUILDING PERMIT FEES 2,466.55 EP 00100003111100 ELECTRICAL PERMIT FEES 172.50 MP 00100003111100 MECHANICAL PERMIT FEES 220.00 PF 00100003112300 PLAN CHECK FEES 234.63 PP 00100003111100 PLUMBING PERMIT FEES 270.00 RF 11100003112700 RECREATION FEES 250.00 UT 11000003106000 USE TAX 40 7,060.00 WC 00100003112800 WILL CALL INSPECTION FEE 20.00 TOWN OF VAIL, COLORADOCopy Reprinted on 01 -03 -2013 at 15:58:25 01/03/2013 Statement ########**##########*###****########*#*######**#*#*########## # # # * * # # # * * * * # # # # # # # # # * # # * # # # # *# Statement Number: R110000231 Amount: $1,603.26 03/28/201102:53 PM Payment Method: Check Init: DR Notation: CK# 1243 CHAD ----------------------------------------------------------------------------- Permit No: Bll -0045 Type: COMBINATION BLDG PERMIT Parcel No: 2101- 082 - 5202 -6 Site Address: 400 VAIL VALLEY DR VAIL Location: TYROLEAN CONDOS UNIT 7 Total Fees: $18,533.19 This Payment: $1,603.26 Total ALL Pmts: $18,533.19 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 1,603.26 ----------------------------------------------------------------------- - - - - -- BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: r, Project #: rK S I I " (Number) (Street) f (Suite #) DRB #: c [Pec) Building /Complex Name: �V-'4 1t°f� ry T^>" • Building Permit #: �1 ©OL1, ) �.w„ o ___._.��• y. ... Lot #: Block # Subdivision: Contractor Information Business Name: ; Work Class: New ( ) Addition (X} Alteration ( ) Business Address: City Contact Name: Contact Phone: Contact E -Mail: Contractor Registration Number: Type of Building: State: Zip: Single- Family ( ) Duplex ( } Multi - Family (y i Commercial( Other( ) Owner /Owner's Representative Signature (Required) Project Information Owner Name: 61ACX 5+0 l it,Ow k6ldk Parcel #: 2 i -- OS 2.-5".2- - o-D. to (For Parcel #, contact Eagle County Assessors Offlce at (970.328 -MO or visit www.eaglecounty.uslpatie) Detailed Scope and Location of Work: (use additional sheet if necessary) For Office Use Only: Fee Paid: Received From: Cash Check # CC: Visa / MC Last 4 CC # Auth # s exp date: Work Type: Interior (�(j Exterior (>6 BothtK) Date Received: pCC�[EC I III MAR 2 5 2011 D TOWN OF VAIL O1- Jan -11 Valuation of Work Included Plans Included Work Electrical (�AYes ( )No ( )Yes ( )No 1� -I,OOp Mechanical (Y )Yes ( )No ( )Yes ( )No ) �� 00 Plumbing O6)Yes ( )No ( )Yes ( )No &00 Building ( )Yes ( )No ( )Yes ( )No ?201 ��© Value of all work being performed: $ 3169,060 d (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage 13 o 3 Date Received: pCC�[EC I III MAR 2 5 2011 D TOWN OF VAIL O1- Jan -11 A & D Asbestos Testing and Consulting John R. Peterman P.O. Box 1230 Clifton, CO. 81520 -1230 Cell 970 - 270 -3689 Home Phone 970- 464 -5265 INSPECTION REPORT PREPARED FOR: Nedbo Construction P.O. Box 3419 Vail, CO. 81658 970 - 845 -1001 LOCATION: The Tyrolean Unit #X7 `u#j I -r 400 E. Meadow Road Vail, CO. 81657. REPORT PREPARED BY: John R. Peterman Inspector Manager Certificate No. 6601 2 A & D Asbestos Testing and Consulting John R. Peterman Asbestos Testing, Project Design, and Consulting INTRODUCTION: On March 14th, 2005, an inspection /survey was conducted and 6 bulk samples were collected from the: The Tyrolean Unit #7 400 E. Meadow Road Vail, CO. 81657. The purpose of the inspection/survey was to locate and sample suspected Asbestos containing materials that might be present in the unit that is planned for renovation. The inspection was made, and the samples were collected by John R. Peterman, an A.H.E.R.A. and State of Colorado Certified Asbestos Inspector. Great care was taken during the inspection and sampling to be as accurate as possible. It should be noted that minimal damage was done to the existing building structures during the inspection so there is no documentation for unseen conditions or stored items. All samples were analyzed by DCM Science Lab in Wheatridge, CO. This laboratory is deemed "Proficient" in the E.P.A.Quality Assurance (QA) program for the determination of asbestos in bulk materials, and is accredited by the American Hygiene Association (AHA). SAMPLING PROTOCOL: A random sampling scheme was used to sample the suspect materials that were discovered. If during any future demolition or renovation work, suspect material is discovered that hasn't been sampled and would be disturbed, work should be halted until the material has been tested. A & D Asbestos Testing and Consulting John R. Peterman AsbestosTesting, Project Design, and Consulting The Tyrolean Unit #17 400 E. Meadow Road Vail, CO. 81657. RENOVATION AREA DESCRIPTION: Unit #67, at The Tyrolean, is planned for renovation work that will impact the inside, and some exterior areas of the unit. The exterior walls are covered with plaster, and the interior walls are covered in sheetrock with a texture, and finished wood. The ceilings are covered in sheetrock with texture, and finished wood like the walls. The floors are covered with carpet, ceramic tiles, and stone tiles. The heating is provided by a fireplace and baseboard heating. CONCLUSIONS & RECOMMENDATIONS: Laboratory analysis of the bulk samples indicate that no Asbestos was detected in any of the bulk samples. 4 Date: March 14, 2005 Location: The Tyrolean, Unit W, 400 E. Meadow Road, Vail, CO. 81657. SAMPLE LOCATIONS SAMPLE NUMBER TY 7 -B 001 TY 7 -B 002 TY 7 -B 003 TY 7 -B 004 TY 7 -B 005 TY 7 -B 006 AREA SAMPLE REMOVED FROM Entry Closet Wall Laundry Room Wall 1st Floor N. Bedroom Closet Wall Upstairs N. Bedroom Closet Wall Upstairs Linen Closet Wall Outside Patio Wall DESCRIPTION Composite Sheetrock w/Texture Composite Sheetrock w/Texture Composite Sheetrock w/Texture Composite Sheetrock w/Texture Composite Sheetrock w/Texture Exterior Plaster FRIABLE NO NO NO NO NO NO Date: March 14, 2005 Location: The Tyrolean, Unit #97,400 E. Meadow Road, Vail, CO. 81657. SAMPLE RESULTS: SAMPLE NUMBER DESCRIPTION ASBESTOS TYPE % TY 7 -13 001 Composite Sheetrock w/Texture NAD 0.00 TY 7 -B 002 Composite Sheetrock w/Texture NAD 0.00 TY 7 -13 003 Composite Sheetrock w/Texture NAD 0.00 TY 7 -13 004 Composite Sheetrock w/Texture NAD 0.00 TY 7 -13 005 Composite Sheetrock w/Texture NAD 0.00 TY 7 -13 006 Exterior Plaster NAD 0.00 KEY: NAD - No Asbestos Detected Date: March 14, 2005 Location: The Tyrolean, Unit #57, 400 E. Meadow Road, Vail, CO. 81657. SUSPECT MATERIAL CONDITIONS SAMPLE NUMBER TYPE OF SUSPECT MATERIAL OVERALL CONDITION DAMAGED % TYPE OF DAMAGE TY 7 -B 001 SUR GOOD NO 0.00 N/A TY 7 -B 002 SUR GOOD NO 0.00 N/A TY 7 -B 003 SUR GOOD NO 0.00 NIA TY 7 -B 004 SUR GOOD NO 0.00 N/A TY 7 -B 005 SUR GOOD NO 0.00 N/A TY 7 -B 006 SUR GOOD NO 0.00 N/A KEY: SUR - Surfacing Date: March 14, 2005 Location: The Tyrolean, Unit #47, 400 E. Meadow Road, Vail, CO. 81657. POTENTIAL FOR DISTURBANCE Sample Number Accessibility Potential Influence Potential Located in Plenum yes/no contact vibration air erosion yes /no TY 7 -13 001 YES HIGH LOW LOW NO TY 7 -13 002 YES HIGH LOW LOW NO TY 7 -13 003 YES HIGH LOW LOW NO TY 7 -13 004 YES HIGH LOW LOW NO TY 7 -13 005 YES HIGH LOW LOW NO TY 7 -8 006 YES HIGH LOW LOW NO TOWN OFYAII Job Name: Job Address: 71 9;: Edo 2 a / J) Permit No.: a t I c Ct J SPECIAL INSPECTION AND TESTING AGREEMENT (To applicants of projects requiring Special Inspection or Testing per Section 1701 of the IBC) The owner or his/her representative, on the advice of the design professional in responsible charge, shall complete, seal, sign and submit a copy of the Special Inspection Agreement and Structural Tests Scheduled to the Town of Vail for review and approval. Signatures are required on both pages; photocopied or faxed signatures are acceptable. The owner and his/her general contractor, where applicable, shall also acknowledge the following conditions applicable to Special Inspection Testing: 1. Contractor is responsible for proper notification to the Inspection or Testing agency for items listed.(Page 1) (113C 1704) 2: Only the testing laboratory should take samples and transport them to their laboratory. 3. Copies of all laboratory reports and inspections are to be sent directly to the Town of Vail by the Testing agency on a weekly basis. 4. Inspection agency to submit names and qualifications of on -site special inspectors to the Town of Vail for review and approval.( Page 2) S. The special inspector is responsible to immediately notify the Town of Vail Building Official in writing of any concerns and/or problems encountered. 6. it is the responsibility of the contractor to review the Town of Vail approved plans for additional inspection or testing requirements that may be noted. A pre - construction conference at the job site is recommended to review special inspection procedures. 7. The special inspector shall use only the Town of Vail approved drawings. 8. All special inspection field reports must be left on site for review by the Town of Vail staff prior to required inspections or re- inspections. BEFORE OCCUPANCY WILL BE GRANTED: The special inspection agency shall submit a signed and sealed statement that all items requiring testing and inspection were fulfilled and reported. Those items not tested and /or inspected shall be noted in this statement. A copy of the statement shall be maintained at the job site for the Building Inspectors review prior to fr�al inspection,. Acknowledgement: Owner.,/ Signature ' Special Inspection_ Agency: Project Arch /Eng: Contractor: (31&4 � S tc t b o.o L L C_ NiGO /4 -S Cc(r -/(:1-/ 7 Print Name Date Print Narne atMe Print Name Liam Print Name Da #e *VAE TO" SPECIAL INSPECTION AND TESTING SCHEDULE (BC 47AA% Project Name: Z tt Permit # Owner's Name: Testing Inspection Signawre Print Name o Agen ' ` Testing Inspection Signature 0;;nt Name Cata Hereby certifies that the Testing /In ct o envy nam above has been engaged to perform structural tests and inspections during construction as checked below, to satisfy all applicable portions of the Building Code. Prior to final inspection, the Inspection Agency shall submit a statement that all items of designated work performed were reported. Any items checked but not tested or inspected will be noted and explained_ Whenever any designated items on the list are ready for sampling, testing, or inspection, it shall be the responsibility of the contractor to give timely notice to the Inspection agency so that the required services may be performed. REINFORCING STEEL: Tenslle & Bend, one set per heat per tons Inspection of Placement Inspection of Welding _ Epoxy MASONRY: Prelim. Acceptance Tests (Masonry Units, Wail Prisms) Subsequent Tests (Mortar, Grout, Field Wall Prisms) Inspection of Placement and Grouting Reinforcing Tests Inspection of Reinforcing Placement Tendon Tests Inspection of Tendon Placement Inspection of Concrete placement Inspection of Concrete Batching inspection of Panel Attachment & Inserts Compression Tests Inspection of Stressing/Transfer PILING, CAISSONS, CAPS, TIES., Inspection of Reinforcing Placement Inspection of Concrete Placement Inspection of Concrete Batch ing Specify other tests, inspections or special instructions roqu,;red, IN UNDERPINNING: Temporary/Permanent Inspection of Steel Fabrication Inspection of Reinforcing & Forms Inspection of Concrete Placement Inspection of Tiebacks SOIL NAILS: Temporary Shoring Permanent Wall STRUCTURAL STEEL: Sample & Test (List speck members below) _ Shop Identification & Welding Inspection Shop Ultrasonic Inspection Shop Radiography _ Field Welding Inspection —� — Feld Bolting inspection Field Ultrasonic Inspection y Field Radiography —7` -- Metal Deck Welding Inspection FIREPROOFING: Inspection & Placement SOILS: Acceptance Tests Moisture- Density Determination Field Density Drilled Piers Deep Foundation STRUCTURAL. WOOD. Inspection of Fabrication Inspection of Truss Joint Fabrication Sample & Test Components Inspection of Glu Lam Fabrication SMOKE CONTROL: SPECIAL CASES: SPECIAL INSPECTION: Seismic Resistance Wind Requirements °2- ?4 -��'" Inspection Request Reporting Page 3 4:34 F'r Vail, CO - City Of vv Requested Inspect Date: Thursday, December 15, 2011 Site Address: 400 VAIL VALLEY DR VAIL TYROLEAN CONDOS UNIT 7 A/P /D Information Activity: B11 -0045 Type: COMBO Sub Type: AMF Status: Const Type: Occupancy: Use: R -2 Insp Area: Owner: BLACK STALLION HOLDINGS INC Contractor: NEDBO CONSTRUCTION INC Phone: 970 - 845 -1001 Description: EXPAND UNIT BY ENCLOSING DECKS TO EAST. ADDITION WILL BE 15.5 FEET FROM PROPERTY LINE. Requested Inspe Item: Requestor: Comments: Assigned To: Action. ction s 90 BLDG -Final NEDBO CONSTRUCTION INC 977 -0329 Time Exp Item: 290 PLMB -Final Requestor: NEDBO CONSTRUCTION INC Comments: 977 -0329 Assigned To: * * * * * * * * * * ** Action: Time Exp: Item: 390 MECH -Final Requestor: NEDBO CONSTRUCTION INC Comments: 977 -0329 Assigned To: * * * * * * * * * * ** Action: Time Exp: Item: 420 Special Inspect -final reps Requestor: NEDBO CONSTRUCTION INC Comments: 977 -0329 Assigned To: Action: Time V� R Com Assigr h� 534 PLAN -FINAL C/O NEDBO CONSTRUCTION IN Exp: Time Exp: Requested Time: 10:15 AM Phone: 970 - 845 -1001 Entered By: JMONDRAGON K Requested Time: 09:00 AM Phone: 970 - 845 -1001 Entered By: JMONDRAGON K Requested Time: 09:30 AM Phone: 970 - 845 -1001 Entered By: JMONDRAGON K Requested Time: 10:00 AM Phone: 970 - 845 -1001 Entered By: JMONDRAGON K Requested Time: 08:15 AM Phone: 970 - 845 -1001 Entered By: JMON RAGON K Item: 100 ELEC -Final G Requested Time: 08:00 AM Requestor: NEDBO CONSTRUCTION INC Phone: 970 - 845 -1001 Comments: 977 -0329 .Assigned To: SGREMMER Entered By: JMONDRAGON K Action: Time Exp: Ccmment: arc tault breaK ers not working shower trims to be installed 2 pcie breaker for multi wire at disposal & dishwasher REPT131 Run Id: 13895 12-14 -2011 Inspection Request Reporting Page 3 4:34 pm Vail, Co - City pf Requested Inspect Date: Thursday December 15, 2011 Site Address: 400 VAIL /ALLEY DR VAIL TYROLEAN CONDOS UNIT 7 A/P /D Information Activity: B11 -0045 Type: COMBO Const Type: Occupancy: Owner: BLACK STALLION HOLDINGS INC Contractor: NEDBO CONSTRUCTION INC Description: EXPAND UNIT BY ENCLOSING DECKS TO EAST LINE. Requested Inspection(s) Item: 90 BLDG -Final Requestor: NEDBO CO TRUCTION INC Comments: ftoT,329 Assigned ts: Action: Time Exp: Item: Requestor: Comments: Assigned To: Action: Item: Requestor: Comments: Assigned To: Action: Item: Requestor: Comments: Assigned To: Action: Item: Requestor: Comments: Assigned To: Action: PLMB -Final 30 CONSTRUCTION INC )329 Time Exp: MECH -Final 30 CONSTRUCTION INC * � * Time Exp: 30 CONSTRUCTION INCt ime Exp: INC 'ime Exp: Sub Type: AMF Status: ISSUED Use: R -2 Insp Area: Phone: 970 - 845 -1001 ADDITION WILL BE 15.5 FEET FROM PROPERTY Item: 190 ELEC -Final Requestor: NEDBO CONSTRUCTION INC Comments: 977 -0329 Assigned To: R Action: Time Exp: Comment: a ers not working fauit s wer trims to be installed 2 le breaker for multi wire at disposal & dishwasher -rte sip kAl Requested Time: 10:15 AM Phone: 970 - 845 -1001 Entered By: JMONDRAGON K Requested Time: 09:00 AM Phone: 970 - 845 -1001 Entered By: JMONDRAGON K Requested Time: 09:30 AM Phone: 970 - 845 -1001 Entered By: JMONDRAGON K Requested Time: 10:00 AM Phone: 970 - 845 -1001 Entered By: JMONDRAGON K Requested Time: 08:15 AM Phone: 970 - 845 -1001 Entered By: JMONDRAGON K Requested Time: 08:00 AM Phone: 970 - 845 -1001 Entered By: JMONDRAGON K Run Id: 13895 g0 k &iu7N µ�F wren o � 7 { � / ') '- 06 -18 -2012 Inspection Request Reporting Page 4 4:24 pm Vail, CO - CitV Of Requested Inspect Date: Tuesday, June 19 2012 Site Address: 400 VAIL VALLEY' DR VAIL TYROLEAN CONDOS UNIT 7 A/P /D Information Activity: B11 -0045 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occupancyy: Use: R -2 Insp Area: Owner: BLACK STALLION HOLDINGS INC Contractor: NEDBO CONSTRUCTION INC Phone: 970 - 845 -1001 Description: EXPAND UNIT BY ENCLOSING DECKS TO EAST. ADDITION WILL BE 15.5 FEET FROM PROPERTY LINE. Requested Inspections Item: 90 k8L-Fi Requested Time: 08:00 AM Requestor: Phone: Assigned To: JM Entered By: SHANE K Action: Time Exp: Comment: ire top handrail to be instal ed Inspection Histo Item: 120 ELEC -Rou h ** Approved ** 05/26/11 Inspector: sgremmer Action: AP APPROVED Comment: 05/31/11 Inspector: sgremmer Action: DN DENIED Comment: Need to see fuse size for AIC rating 10/04/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH -Rough ** Approved ** 09/27/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 230 PLMB- Rough/Water ** Approved ** 09/27/1 T Inspector: sgremmer Action: AP APPROVED Comment: Item: 240 PLMB -Gas Piping ** Approved ** 10/04/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 310 MECH - Heating ** Approved ** 10/04/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 30 BLDG - Framing ** Approved ** 06/15/11 Inspector: mdenney Action: PI PARTIAL INSPECTION Comment: (3) LVL beam at east exterior wall. steel column bolted to beam. 10/04/11 Inspector- sgremmer Action: AP APPROVED Comment: ok per engineer letter Item: 50 BLDG - Insulation ** Approved ** 10/07/11 Inspector: JRM Action: AP APPROVED Comment: Item: 410 Special Inspect- progress re pt ** Approved ** NO NOTIFIED 10/05/11 Inspector: JAM Action: Comment: PER THUNDER MTN.. SPECIAL INSPECTION DENIED. DOC SCANNED 01/26/12 Inspector: JRM Action: AP APPROVED Comment: Item: 60 BLDG - Sheetrock Nail ** Approved ** 10/18/11 Inspector: sgremmer Action: AP APPROVED Comment: REPT131 Run Id: 14559 06 -18 -2012 Inspection Request ReportingflI_� Wage 4 d 7d nm Vail .0 Ci1v O �..JJ Requested Inspect Date: Tuesday, June 19 2012 Site Address: 400 VAIL VALLEY' DR VAIL TYROLEAN CONDOS UNIT 7 A/P /D Information Activity: B11 -0045 Type: COMBO Const Type: Occupancy: Owner: BLACK STALLION HOLDINGS INC Contractor: NEDBO CONSTRUCTION INC Description: EXPAND UNIT BY ENCLOSING DECKS TO EAST LINE. Reauested Inspections Item: Requestor: Assigned To: Action: Comment: Inspection Histo 90 BLI JMO [ ire handra W74� Time Exp I to be installed q D I a it Z'�-- Sub Type: AMF Status: ISSUED Use: R -2 Insp Area: Phone: 970 - 845 -1001 ADDITION WILL BE 15.5 FEET FROM PROPERTY Requested Time: 08:00 AM Phone: Entered By: SHANE K Item: 120 ELEC -Rough ** Approved ** 05/26/11 Inspector: sgremmer Action: AP APPROVED Comment: 05/31/11 Inspector: sgremmer Action: DN DENIED Comment: Need to see fuse size for AIC rating 10/04/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH -Rough ** Approved ** 09/27/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 230 PLMB- Rough/Water ** Approved ** 09/27/1 T Inspector: sgremmer Action: AP APPROVED Comment: Item: 240 PLMB -Gas Piping ** Approved ** 10/04/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 310 MECH - Heating ** Approved ** 10/04/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 30 BLDG - Framing ** Approved ** 06/15/11 Inspector: mdenney Action: PI PARTIAL INSPECTION Comment: (3) LVL beam at east exterior wall. steel column bolted to beam. 10/04/11 nspector: sgremmer Action: AP APPROVED Comment: ok per engineer letter Item: 50 BLDG - Insulation **A pproved ** 10/07/11 Inspector: JRM Action: AP APPROVED Item: 410 Special Inspect- progress rept ** Approved ** 10/05/11 Inspector: JRM Action: NO NOTIFIED Comment: PER THUNDER MTN.. SPECIAL INSPECTION DENIED. DOC SCANNED 01/26/12 Inspector: JRM Action: AP APPROVED Comment: Item: 60 BLDG - Sheetrock Nail ** Approved ** 10/18/11 Inspector: sgremmer Action: AP APPROVED Comment: REPT131 Run Id: 14559