HomeMy WebLinkAboutB11-0048NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inlasections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11 -0048 Job Address: 9 VAIL RD VAIL Location......: COMMON ELEMENT Parcel No....: 210107106000 CONTRACTOR ALPINE MOUNTAIN BUILDERS INC 08/03/2011 Phone: 970 - 926 -8703 105 EDWARD VILLAGE BLVD, STE. A205 EDWARDS CO 81632 License: C000003134 APPLICANT 9 VAIL ROAD HOA 03/31/2011 OWNER 9 VAIL ROAD HOA 03/31/2011 Description: REROOF AND REVISED FASCIA DETAIL. REMOVE EXISTING WOOD SHAKE, COLD ROOF. REPLACE WITH INCREASED INSULATION AND 30 YR COMPOSTION SHINGLES. Occupancy: R2 /S2 Type Construction: IIA Project #: Applied.....: Issued...: P RJ 11 -0005 03/31/2011 09/06/2011 Valuation: $500,000.00 ............................................... .... «......,....,.........._... FEE SUMMARY ......_.....»......................,,......... «....................,....,.._. Building Permit ------ - - - - -> $3,233.75 Bldg Plan Check ----- - - - - -> $2,101.94 Use Tax Fee------------------ - - - - -> $9,800.00 Electrical Permit ---- - - - - -> $0.00 Elec Plan Check ------ - - - - -> $0.00 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $0.00 Mech Plan Check ---- - - - - -> $0.00 Additional Fees--------------- - - - - -> $0.00 Plumbing Permit --- - - - - -> $0.00 Plmb Plan Check ---- - - - - -> $0.00 Recreation Fee--------------- - - - - -> $0.00 Investigation------------------ - - - - -> $0.00 Will Call ------------------------------ > $5.00 TOTAL PERMIT FEES --- ---------- > $15,140.69 Payments -- ---------------------------- > $15,140.69 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FO NSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:90 M. c nature of Owner or Contractor D e Print Name combination permit_012811 TMO W N NEN CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: 611 -0048 Address: 9 VAIL RD VAIL Owner: 9 VAIL ROAD HOA Location: COMMON ELEMENT Cond: CON0011838 All exterior materials and colors shall be consistent with design review approval DR13110009. combination permit_012811 a� A TOWN OF VAIL REQUIRED INSPECTIONS AND STATUSES Permit #: B11 -0048 Address: 9 VAIL RD VAIL Owner: 9 VAIL ROAD HOA Location: COMMON ELEMENT Item: 00050 BLDG - Insulation Item: 00030 BLDG - Framing Item: 00534 PLAN - FINAL C/O Item: 00090 BLDG -Final combination permit_012811 TOWN OF VAIL, COLORADO Statement Statement Number: R110001150 Amount: $9,800.00 09/06/201103:46 PM Payment Method: Check Init: SAB Notation: 29313 - ALPINE MOUNTAIN BUILDERS ----------------------------------------------------------------------------- Permit No: Bll -0048 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 071 - 0600 -0 Site Address: 9 VAIL RD VAIL Location: COMMON ELEMENT Total Fees: $15,140.69 This Payment: $9,800.00 Total ALL Pmts: $11,900.00 Balance: $3,240.69 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------ ------------------ - - - - -- ------ - - - - -- UT 11000003106000 USE TAX 416 9,800.00 TOWN OF VAIL, COLORADO Statement Statement Number: R110001151 Amount: $3,240.69 09/06/201103:47 PM Payment Method: Check Init: SAB Notation: 1133 - HOLIDAY HOUSE CONDO. ----------------------------------------------------------------------------- Permit No: Bll -0048 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 071 - 0600 -0 Site Address: 9 VAIL RD VAIL Location: COMMON ELEMENT Total Fees: $15,140.69 This Payment: $3,240.69 Total ALL Pmts: $15,140.69 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 BUILDING PERMIT FEES 3,233.75 PF 00100003112300 PLAN CHECK FEES 1.94 WC 00100003112800 WILL CALL INSPECTION FEE 5.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADOCopy Reprinted on 01 -03 -2013 at 15:43:23 01/03/2013 Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R110000244 Amount: $2,100.00 03/31/201102:01 PM Payment Method: Check Init: DR (PTARMIGAN MGMNT) Notation: CK# 1129 TOM S. ----------------------------------------------------------------------------- Permit No: Bll -0048 Type: COMBINATION BLDG PERMIT Parcel No: 2101 - 071 - 0600 -0 Site Address: 9 VAIL RD VAIL Location: COMMON ELEMENT Total Fees: $15,140.69 This Payment: $2,100.00 Total ALL Pmts: $15,140.69 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 2,100.00 )epartment of Community Development s 75 South Frontage Road ; Vai1,.Colorado .81657 ' Tel: 970- 479 -2128. Web: www.vailgov.com Development Revieaty CAOr_dW a# BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: Project #: tf R� 1 �� iJ 005 0 V,9-11- l� 0 A� ) (Number) (Street) (Suite #) DRB #: ,l ge I OD09 Building /Complex Name: V I L T�o P�,� Building Permit #: a) I— DOLI R Contractor Information Business Name: Business Address: City State: Zip: Contact Name: Contact Phone: Contact E -Mail: Contractor Registration Number: X Owner /Owner's Representative Signature (Required) Project Information Owner Name: t� Parcel #. 01 1. D I -- O6 no — D (For Parcel #, contact Fagle County Assessors Office at (970- 328 -8640 or visit www.eaglecounty.us/patie) i Detailed Scope and Location of Work: �� w CD P� Lot #: Block # Subdivision: Work Class: New ( ) Addition ( ) Alteration ( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family ( ) Commercial( ) Other( ) Work Type: Interior ( ) Exterior ( ) Both ( ) (use additional sheet if necessary) SCANNED For Office Use Only: Date Received: Fee Paid: $ ;R,, I DO 00 Received From: Tnm S- FOR 1�111 Dt -MA'1 1401159 C0JU00 Cash Check #I ► � 9 145614, CC: Visa / MC Last 4 CC # exp date: Auth # MAR 3 0 2011 TOWN OF VAIL O1- Jan -11 Valuation of Work Included Plans Included Work Electrical ( )Yes (N o ( )Yes ( )No Mechanical ( )Yes ( �o ( )Yes ( )No Plumbing ( )Yes (-\-)No ( )Yes ( )No Building (PYes ( )No ( Yes ( )No Value of all work being performed: $ uno 000 (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage (use additional sheet if necessary) SCANNED For Office Use Only: Date Received: Fee Paid: $ ;R,, I DO 00 Received From: Tnm S- FOR 1�111 Dt -MA'1 1401159 C0JU00 Cash Check #I ► � 9 145614, CC: Visa / MC Last 4 CC # exp date: Auth # MAR 3 0 2011 TOWN OF VAIL O1- Jan -11 $\J., OD4 b INDEPENDENT TESTING & INSPECTION SERVICES INC. 12084 VASEEN CT. CONIFER, COLORADO 80433 303 - 674 -7560 FAX 303 - 674 -7560 Client: Alpine Mountain Builders Project: 9 Vail Road Condos Inspector: David L. Sturgeon Page 1 of 2 OBSERVATION REPORT ITIS Job No. 092911 Location: Vail, CO Date: 6 -20 -12 This report package contains information concerning specific tests and inspections of structural steel welding, structural bolting, structural sprayed fireproofing, and /or nondestructive testing. The specific criteria utilized in judging the degree of conformance for each area of inspection are contained on each individual inspection form. Also included may be ITIS' "List of Outstanding Discrepancies" (O.D. List). The O.D. List will be consecutively numbered for each page issued throughout the duration of the project. Each individual item listed will also be consecutively numbered. If there are any questions regarding the content of this report, please feel free to contact ITIS at your convenience. David L. Sturgeon President ICBO Certified Inspector #1138247 -85 AWS QC -1 #82122691 Resident Level III INDEPENDENT TESTING & INSPECTION SERVICES INC. 12084 VASEEN CT. CONIFER, COLORADO 80433 303 - 674 -7560 FAX 303 - 674 -7560 Page 2 of 2 INITIAL VISUAL INSPECTION OF WELDING FIELD REPORT FORM Inspector: David L. Sturgeon Job No. 092911 Date: 6 -20 -12 Field Made Welds Shop Made Welds Type of Welds Inspected: Fillet Groove Other Type of Component (i.e.: Column, beam girder, moment weld, etc) Screwed Connections Applicable Code or Standard: IBC and Project Standards AREAS OF INSPECTION LEVEL OR ELEVATION: Roof Dwg. A -4, Sections A -F I Installation and Fastening SOUTH BUILDING GRID LINE LOCATON(S): Half of Roof North of Peak CONDITIONS OF NONCONFORMANCE / INSPECTION RESULTS: The installations were viewed and found conforming. One roof connection needed a longer vertical leg on the connection angle. The Erector replaced the connection angle, and the connection angle was found conforming LEVEL OR ELEVATION: GRID LINE LOCATION(S): CONDITIONS OF NONCONFORMANCE / INSPECTION RESULTS: i . I 1, D° Lit INDEPENDENT TESTING & INSPECTION SERVICES INC. 12084 VASEEN CT. CONIFER, COLORADO 80433 303 - 674 -7560 FAX 303 - 674 -7560 Client: Alpine Mountain Builders Project: 9 Vail Road Condos Inspector: David L. Sturgeon Page 1 of 2 OBSERVATION REPORT ITIS Job No. 092911 Date: 6 -6 -12 Location: Vail, Colorado This report package contains information concerning specific tests and inspections of structural steel welding, structural bolting, structural sprayed fireproofing, and /or nondestructive testing. The specific criteria utilized in judging the degree of conformance for each area of inspection are contained on each individual inspection form. Also included may be ITIS' "List of Outstanding Discrepancies" (O.D. List). The O.D. List will be consecutively numbered for each page issued throughout the duration of the project. Each individual item listed will also be consecutively numbered. If there are any questions regarding the content of this report, please feel free to contact ITIS at your convenience. David L. Sturgeon President ICBO Certified Inspector #1138247 -85 AWS QC -1 #82122691 Resident Level III INSPECTION SERVICES INC. 12084 VASEEN CT. CONIFER, COLORADO 80433 303 - 674 -7560 FAX 303 - 674 -7560 Page 2 of 2 INITIAL VISUAL INSPECTION OF WELDING FIELD REPORT FORM Inspector: David L. Sturgeon Job No. 092911 Date: 6 -6 -12 Field Made Welds Shop Made Welds Type of Welds Inspected: Fillet Groove Other Type of Component (i.e.: Column, beam girder, moment weld, etc) As Recorded Applicable Code or Standard: AWS, IBC and Project Standards AREAS OF INSPECTION LEVEL OR ELEVATION: Roof Level, Drawing A4, Sections A -F, MAIN BUILDING GRID LINE LOCATON(S): South Roof CONDITIONS OF NONCONFORMANCE / INSPECTION RESULTS: The installation of the 20 gage was inspected pursuant to the referenced sections of Drawing A4. Two areas were found needing additional fasteners ( #10 screws): the dormer valley and ridge and on the high ridge back to back channel framing. The GC was informed, and the deficiencies marked. All remaining connections were found conforming. LEVEL OR ELEVATION: GRID LINE LOCATION(S): CONDITIONS OF NONCONFORMANCE / INSPECTION RESULTS: 12 -26 -2012 Inspection Request Reporting Page 4 8:14 am P Vail_ r.n . cifv ()f 9 Ell / 9 Requested Inspect Date: Thursday December 27, 2012 Site Address: 9 VAIL RD VAIL COMMON ELEMENT A/P /D Information Activity: B11 -0048 Type: COMBO Sub Type: ACONDO Status: ISSUED Const Type: Occupancy: Use: R2 /S2 Insp Area: Owner: 9 VAIL ROAD HOA Contractor: ALPINE MOUNTAIN BUILDERS INC. Phone: 970 - 926 -8703 Description: REROOF AND REVISED FASCIA DETAIL. REMOVE EXISTING WOOD SHAKE, COLD ROOF. REPLACE WITH INCREASED INSULATION AND 30 YR COMPOSTION SHINGLES. Requested Inspection(s Item: 534 PLAN -FINAL C/O Requested Time: 08:00 AM Requestor: Phone: Comments: close out Assigned To: BGIBSON Entered By: JMONDRAGON K Action: � Time Exp: Item: 90 BLDG -Final Requested Time: 09:00 AM Requestor: Phone: Comments: close out Assigned To: JMONDRAGON Entered By: JMONDRAGON K Action: Time Exp: Comment: Inspection History Item: 50 BLDG - Insulation ** Approved ** 10/13/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: west side 10/17/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 30 BLDG - Framing ** Approved ** 10/13/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: west side 10/17/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 534 PLAN -FINAL C/O Item: 90 BLDG -Final ** Approved ** 08/21/12 Inspector: sgremmer Action: AP APPROVED Comment: REPT131 Run Id: 14632 fir 12 -26 -2012 Inspection Request Reporting - Page 4 8.14 am Vail CO - Cifu Of Requested Inspect Date: Thursday, December 27, 2012 Site Address: 9 VAIL RD VAIL COMMON ELEMENT A/P /D Information Activity: 1311 -0048 Type: COMBO Sub Type: ACONDO Status: ISSUED Const Type: Occupancy: Use: R2 /S2 Insp Area: Owner: 9 VAIL ROAD HOA Contractor: ALPINE MOUNTAIN BUILDERS INC. Phone: 970 - 926 -8703 Description: REROOF AND REVISED FASCIA DETAIL. REMOVE EXISTING WOOD SHAKE, COLD ROOF. REPLACE WITH INCREASED INSULATION AND 30 YR COMPOSTION SHINGLES. Reauested Insoection(s Item: 534 PLAN -FINAL C/O Requested Time: 08:00 AM Requestor: Phone: sgremmer Comments: close out Comment: west side Assigned To: BGIBSON Entered By: JMONDRAGON K Action: Time Exp: Action: AP APPROVED Item: 90 BLDG -Final Requested Time: 09:00 AM Requestor: Item: Phone: ** Approved ** Comments: close out 10/13/11 Inspector: Assigned To: JMONDRAGON Entered By: JMONDRAGON K Action: Time Exp: Comment: west side Inspection Histo Item: 50 BLDG - Insulation ** Approved ** 10/13/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: west side 10/17/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 30 BLDG - Framing ** Approved ** 10/13/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: west side 10/17/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 534 PLAN -FINAL C/O Item: 90 BLDG -Final ** Approved ** 08/21/12 Inspector: sgremmer Action: AP APPROVED Comment: REPT131 Run Id: 14632