Loading...
HomeMy WebLinkAboutB09-0076NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MEOFVK .• Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 ADD /ALT MF BUILD PERMIT Job Address: 610 W LIONSHEAD CIR VAIL Location......: UNIT 18, LANDMARK Parcel No....: 210106307018 OWNER VANDERHOUT, JAMES H. & PATRI 05/04/2009 9450 N REGENT CT MILWAUKEE WI 53217 APPLICANT ALTER DESIGN BUILDERS LLC 05/04/2009 Phone: 476 -4033 5500 W. HOWARD ST. SKOKIE IL 60077 License: 352 -A CONTRACTOR ALTER DESIGN BUILDERS LLC 05/04/2009 Phone: 476 -4033 5500 W. HOWARD ST. SKOKIE IL 60077 License: 352 -A Description: INTERIOR REMODEL & ADDITION (UNIT 18) Occupancy: R -2 Type Construction: I I IA Permit #: B09 -0076 Project #: PRJ09 -0128 Status .. : ISSUED Applied ..: 05/04/2009 Issued...: 07/22/2009 Expires ...: 01/18/2010 Valuation: $60,000.00 Total Sq Ft Added: 152 ..................................,.......,,.,,,,, ...<.,....,..,...............,. FEE SUMMARY ...............................,,.......,,...... ....,,......,.,........,..,.... Building Permit Fee - - - - -> $713.75 Will Cal Fee---------- - - - - -> $4.00 Total Calculated Fees------ - - - - -> $2,333.69 Plan Check -- -------- - - ---> $463.94 Use Tax Fee ------ ---- ------ > $1,000.00 Additional Fees -- ------- ---- - - - - -> $0.00 Add'I Plan Check Hours- $0.00 Restuarant Plan Review - - - - -> $0.00 TOTAL PERMIT FEES -------- ----- > $2,333.69 Investigation -------- — ------- > $0.00 Recreation Fee -------- -- ----- > $152.00 Payments- - - - - -- - ---- -> $2,333.69 Total Calculated Fees--- - - - - -> $2,333.69 BALANCE DUE — ---- ----- - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. It REQUESTS FOR INSPECTION S 4:00 PM. Signature OH ner or Print Nam -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM Date bid — a It construction _perm it_041908 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R090000890 Amount: $2,333.69 07/22/200902:55 PM Payment Method: Check Init: JLE Notation: 41857 ALTER DESIGN BUILDERS ----------------------------------------------------------------------------- Permit No: B09 -0076 Type: ADD /ALT MF BUILD PERMIT Parcel No: 2101 - 063 - 0701 -8 Site Address: 610 W LIONSHEAD CIR VAIL Location: UNIT 18, LANDMARK Total Fees: $2,333.69 This Payment: $2,333.69 Total ALL Pmts: $2,333.69 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code -------------- Description Current Pmts - - - BP 00100003111100 - -- ----- ------------------- - - - - -- ------ - - - - -- BUILDING PERMIT FEES 713.75 PF 00100003112300 PLAN CHECK FEES 463.94 RF 11100003112700 RECREATION FEES 152.00 UT 11000003106000 USE TAX 4% 1,000.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 Separate permits are required for electrical, plumbing, mechanical, fireplace, etc. Project Street Address: 610 West Lionshead Circle Unit 18 (Number) (Street) (Suite #) Building/Complex Name: The Landmark Condominiums Contractor Information: Company: Alter Design Builders Company Address: 5500 W. Howard St. Office Use: Project #: �J � DRB #: ` r 0 + �� Buildi Permit #: ��lJ Lot #J_ Subdivision: Detailed Description of Work: Interior Renovation of City: Skokie State: IL Zip: 60077 West Tower Unit 18 with added bath & flex space. Contact Name: Howard Olsen Contact Phone: 970 476 -4033 @ 9 P• , E - Mail holsen alter rou com (use additional sheet if necessary) t Work Class: Town of V Con ctor Registration No.: 352 -A New ( ) Addition ( ) Remodel Repair ( ) Other ( ) Work Type Cont ctor Signature (requ red) Interior ) Exterior ( ) Both ( ) Property Information Parcel #: 210106307018 (For parcel #, contact Eagle County Assessors Office at 970- 32 "64Q or visit www.eaglecouty.us/patie) Tenant Name: Owner Name: James Vanderhout Valuations (Labor & Material)) Building: $ $30,000.00 Plumbing: $ $8,000.00 Electrical: $ $16,000.00 Mechanical: $ $6,000.00 Total: $ $60,000.00 Type of Building: Single - Family ( ) Duplex ( ) Multi - Family (� ) Commercial( ) Other( ) Does a Fire Alarm Exist? Yes( No( ) Monitored Alarm? Yes (r) No( ) Does a Sprinkler System Exist? Yes(. No( ) IN MOG # & Type of Existing Fireplaces: Gas Appliances 1 Gas Log Wood /Pellet Wood Burning # & Type of Proposed Fireplaces: Gas Appliances 1 Gas Log Wood /Pellet Wood Burning Date Received: D �C� 0 �n APR 3 0 2009 TOWN OF VAIL BUILDING PERMIT APPLICATION Town of Vail OF Fi VA0. FI/ OP 101 Vail Fire Department Asbestos Testing & Abatement Requirements Q�+cr ae Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from exposure to harmful asbestos. The Town of Vail asbestos abatement program is in addition to the State of Colorado's regulations. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testing required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two - Family Dwellings: 30 square feet All Others: 160 square feet Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1 % require abatement by a State - certified and Vail- registered abatement contractor. An asbestos abatement permit must be approved, and the clearance letter must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My project falls into the category checked below: ❑ Will not disturb more than the threshold limits identified above 9 Tested negative, or at 1% or below (2 copies of test results included) ❑ Tested positive at more than 1 %, requires abatement (2 copies of test results included Tips & Facts: • Even recent construction projects may include asbestos-containing materials, so buildings of any age require testing. • The "1989 Ban" on asbestos - containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so- called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos - containing product categories was set aside and did not take effect." - CDPHE Asbestos test results and abatement permit applications should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: David Rhoades, Fire Inspector Vail Fire Department 75 S Frontage Rd drhoades @vailgov.com 970 -477 -3454 www.vailgov.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303 -692 -3158 asbestos @state.co.us 2 \1�7 www.cdohe.state.co.us D V/ APR 3 01009 OF VAIL Z flu , "i _rVI i . l 4 i A & D Asbestos Testing and Consulting John R. Peterman P.O. Box 1230 Clifton, CO. 81520 -1230 Cell 970- 270 -3689 Home Phone 97OA64 -5265 INSPECTION REPORT PREPARED FOR: Destination Resorts 610 W. LionsHead Circle Vail, CO. 81657 LOCATION: The LandMark 610 W. LionsHead Circle Vail, CO. 81657 REPORT PREPARED BY: John R. Peterman Inspector Manager Certificate No.. 6601 Town of Vail OFFICE COPY L�C�L OdL� D r APR 3 0 2009 � 2 TOWN OF VAIL z A & D Asbestos Testing and Consulting John R. Peterman Asbestos Testing, Project Design, and Consulting INTRODUCTION: On August 2211d, 2006, an inspection/survey was conducted and 20 bulk samples were collected from the: The LandMark 610'W. LionsHead Circle Vail, CO. 81657 The purpose of the inspection/survey was to locate and sample suspected asbestos containing materials that might be present in the Residence that is planned for demolition. The inspection was made, and the samples were collected by John R. Peterman, an A.H.E.R.A. and State of Colorado Certified Asbestos Inspector. Great care was taken during the inspection and sampling to be as accurate as possible. It should be noted that minimal damage was done to the existing building structures during the inspection so there is no documentation for unseen conditions or stored items. All samples were analyzed by DCM Science Lab in Wheatridge, CO. This laboratory is deemed `Proficient" in the E.P.A.Quality Assurance (QA) program for the determination of asbestos in bulk materials, and is accredited by the American Hygiene Association (AHA). SAMPLING PROTOCOL: A random sampling scheme was used to sample the suspect materi als that were discovered. If during any future demolition or renovation work, suspect material is discovered that hasn't been sampled and would be disturbed, work should be halted until the material has been tested. A & D Asbestos Testing and Consulting John R. Peterman AsbestosTesting, Project Design, and Consulting The LandMark 610 W. LionsHead Circle Vail, CO. 81657 MOLDING DESCRIPTION: The LandMark consists of two multi -story buildings with a connecting underground parking garage. The Tower Building is the east building with seven stories, and a garage level. The Town House building has single level units on the first floor, and loft units on the tip levels. This survey covers the inside of the buildings. The interior walls are covered in sheetrock with a light texture, and wood paneling. Note: In some areas a texture has been troweled over the original finish. The ceilings are sheetrock with a heavy spray -on texture, and twin tee concrete with the same spray -on texture. The basement area has suspended ceiling tiles throughout, and most have been replaced not long ago. The older tiles were tested in the Billy's Grill area. The floors are covered with carpet, ceramic tiles, and sheet vinyl flooring. The sheet vinyl was not tested in this survey. The heating is provided by baseboard heating, and fireplaces. No suspect thermal system insulation was observed during this inspection. The garage ceiling had a spray -on fire proofing that was mostly removed prior to this inspection. CONCLUSIONS AND RECOMMENDATIONS: Presumed Asbestos containing materials, present in the buildings, are as follows: 1. Spray -on ceiling texture 2. Sheet vinyl flooring 3. Exterior siding board 4 A & D Asbestos Testing and Consulting John R. Peterman AsbestosTesting, Project Design, and Consulting Laboratory Analysis of the bulk samples collected during this inspection indicate that Asbestos was detected in all of the composite sheetrock samples. However, the Asbestos content is less than the Regulatory Limit (Greater than 1 % Asbestos). The Asbestos content of the samples was verified by the Required Point Count Analysis. The samples collected were taken from the original areas of the buildings. If conditions are encountered that are not the original construction, additional testing or documentation may be required. H the renovation work will impact on the three presumed Asbestos containing materials listed, the P.A.C.M. must be handled as per Colo. Reg. #8 prior to disturbance of the materials. 5 r W J a 000200 00000000000000 W W W W W W zz z z Z Z Z Z Z Z Z Z Z Z 3 3 3 3 3 3 3 3 3 3 3 3 3 alOJila YYYYYicMM X J9jC.YY c c : 0 00 0 L g L L z Q 8S88i��8 r8o 0 a E o ttr cstr.c rttr Y. Y. {L 0 0 0 0. 0 0 0 AM O O co N 0 0 0 a c c cr-f = 1= = = I 8a� �r� S �$ L Q M N w ' 5 0 0 a N a* a to 0 i.Zae C co CL 9L ILC LCCCCC m co — =HEEEEEEEEEEEEEE o v v � L3�3 38 80 0 3 80 0 So o Q 3c3 6 U +, > o V o 000 o g 0 V rJ 0 cc �o` �"$��r�..E� EE Y U. s`•o o N gvB �• V W �.�� VVmVVVVV O 0013 pa. 0 �u = == o f E E E E E M 11 v N B e t e 9 0ZMW b ECG !: M lu mmm i1m M o mm a �E: 0 1 Q W _ '_ m wm a p 6 1 6c � J " =m mm3ui5W'X i3 a.a a�sm a d a a ��O�pp�OO�NNOM��jjr10 OwNin O N o O NaaaV 40 lu .-_�333�33�3w33333 o w o o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ` z a DOt'i ..tip!•- i�F- i- 1- F- F+f- 1- F -1-F -F a O m N c M l7 Yf [� O O r N @7 w 40 n CD W O O 7T *' *- T' T r r r C' g $oSg3$oa00000c000 ++ m 0 Z lu IM= W a mmmmmmmmmmmmmmmmmmmm (f1 JJJJJJJ J JJJJJ -IJJ rNl9�! 1A t�t�aDp 0 rNOfd tAfG1��DfAO D J C! V- V- V- r r r r r r V- N ° o- ° o�$g ° oo�oog000 N OO�ao� O a � a a c Q O m c p O V O c i- I c=iza W a to ZZZ ZZwmw ��wccIEIc g co W xxssxxsssxsxss 000000 00 0000 to r a cc O U _w m _L x U J wF H� C C C 9 G 3 3 3 3 3 3 11 3 3 3 3 3 = co M0 YYYYYYYYYYYY YY C C G 0 0000000000 Al. -b 2s .. 00 8 C J Z _O 'Q- �SII:I � rrrrrrrrr .crrr !It wcacc NN01NNNN NN d 0 � 0 0 0 0 0 0 R H MMEE NN p IC C C c c as C.. a aaaa p E p E o EEEE o EE4 o E p EE p E v * 88 )VC7SS0 m 02 H cc m r- W P QrNORW t0ID�aOOO O r6V r V T rt - rq i l i l cl o O o 0 0 0 COMM 0 0 00 0 N Z ai 3 3G 0 W a. mmmmmmmmmmmmmmmmmmmm . . . - . • f . . . . . . Q a N J J J J J J J J J J J J J J J J J -i -i -i D J (/� - N rr�- rm�r�N Y a � a a c Q O m c p O V O c i- I c=iza E 9L c so zzzzzzzzzzzzzzzzzzzz s� _ c 0 33333333333333333333 am °A°q9 °O 00J0000000000 N a me c 33333333333333333333 00000000000000000J00 O cA V m v C� �q 333 = = =sxsxxrxxx 000 � � � JJJ��'� =Sx xxzSSx =xxss O c V o N N N N N N N N W co N yy to N N N N N N N WIi1WWWWWWWWWW WWWWWWW } } } } } } X vi } } } } } }'y. } } } } }} i CD a ^ FM Q om 0 L N = T ' c � c � O y �q ^��O*'NNRIDfOhdOC10 J (� 3 ��5o25 8g000000000000� N z m Q. mmmmmmmmmmmmmmmmmmmm N r r r r r r r r r r r r r r r r r• r• } � E„� JJJJJJJ JJJJ J1 Y J QI rN Pfd 1p�ptiQpO V W tOPaD0�0 r yr r r r r r r N r L O O 2 W v Q a 0 U . W }��aaaaaaaaaaaaaaaaa IL aa33�z33333333333333 °O$O ° oSS ° o S ° o ° oSgo o SSS o o ° oS � SS$oc000000c00000000 T T T 0 W a 000 00000000000000000 4 }w}zzzzzzzzzzzz.zzzzz a 0 r� m z O_ r t 0 0 O 0 U v w _ � J J a �QOGOCGCGOGGCCQ�GGOGGG _ 00000000000000000000 lu 00000000000000000000 o.advv vvvvv vaaa vvvvvv v O V v c Z W �a � w J 0 �acor vvvat¢o�¢QOC¢acmoco�¢¢ac 1- Y O -0 N. W m /iY� � Q O O T T T T p T T� T v- (V G7 v S z b W 3 to U IL mmmmmmmmmmmmmmmmmmmm a O W Q • • • • • • • • • 4 • • • • • • • • • • • W rat j iA .'�Ars.' j -J i-i �� iAj-i J J J J J J J J J J J J J J J Y w - NO�•poD1�e00aOTNlhst•Amt�a 0 J T T T T T T T T T T N N s e z = v a 1. 2 k Go Go -d Q y fA I w o 0 0 00 00 0o g000 00000 <� S 9 g 99 s$ 98 8999 89999 y O O O p O O p O O p O O p O 1 O pq O� p O p O W? C? tp N ON O ON 89 g8gog ' Wb oz q q q qo 00 oq oggo ogooy a g �, o h °$ d o dog 0008 t � U O c � 3 _ H go O 00 00 OO R8 00 c $ooA z �0% ena �a Na NNE! a ...�vi- 3 a w0 o � N a OD OO Mn 00 N N N 00 Op 00 qO 00 r a V ��z O CS $ g g o - $ - $ - - $ o $ - S - S g g $ E,U S 0000 C? C? 0000 0000 C C? ao ° a ga ° a 8� ° 0 $°tco+ good z zzo U h y o000 0000 000 O x O O . rA o No S. �N��o ppGG o o o N ob O C4 O 0 V taCaUagj .�n C7 N••m .-.NN Nin viq .. tV �G N sr N N a0 a o n O Z o A aA a A a o .g A <aRUA <c�UA t 0 < GD Ci A e �o � , H y 00 F� ao f/ o 8 m <�a p 0 0 0 O O O o O p O O o O O O O O O p O O 8888 C1 888 8888 8888 8885 0 LLLFFFRRRsss � . p ohoo C! C! p on0o hoop m O SO OO SO� C,m g8Oq R W F . ox z� h �N o000 0000 0000 0000 0000 .�+ O GO$N CCgN OOON oO8N 000eV 8 � w C GG � z N �3 �z o� G� 1 o 10 0 � w � [� P� w � 3 p Qe � .-1 bSC4 �i�io3oS� $08� oo�i C4� evm%o� .-•C4V Nm�c� ...N7m < oo] 3 3 ,$ O aA Aq�gA�QQO�Q A� F N h O oD 00 co h i 00 V <e 2 , a .� oq a w z °O � CIO Q Wmm0. !! V � N - � z � � V U W Na O Oe oD OD l" b <aH 2 5 y ` qc7 <ai c �w 8 0 Wo 0. z �a� H a 0. F s U v b A b . A a 0 0 0 0 0 0 0 0 8988 8898 0C! oov►o �$�a gQaa I o 0 0 0 0 0 0 0 O C o N O y O N 9 e U OO 9 C R�- �R1UA �ctgUA � Z 4 b . q a d1 a o w E DCM SCIENCE LABORATORY, INC. 025% AMOSTIE 12421 W. 49TH AVENUE, UNIT #6 CROCIDOLITE ND WHEAT RIDGE, CO 80033 (303) 463 -8270 ND ANTHOPHYLLTTE BULK ASBESTOS ANALYSIS - POINT COUNT METHOD TOTAL ASBESTOS COUNTED PAGE I OF 4 TOTAL ASBESTOS IN LAYER 0.25% CLIENT: ANALYSIS DATE: 8 -31-06 NOTES: SAMPLES NO. I - 5 ARE WHITE DRYWALL MUD. A&D ASBESTOS TESTING REPORTING DATE: 8 -31-06 ND 653 36 1/4 ROAD RECEIPT DATE: 8 -28-06 0.25% PALISADE, CO 81526 CLIENT JOB NO.: THE LANDMARK 0.75% PROJECT TITLE. 610 W. LIONSHEAD CR. - VAIL DCMSL PROJECT: ADAl290 0.01% CROSS REFERENCE: ADA1789 PERCENTAGE COMPOSITION BY AREA/VOLUME DCM LAB NO.: -1 -2 -3 -4 -5 SAMPLE DATE: 8 -22-06 8 -22-06 8 -22-06 8- 22-06 8 -22-06 % OF TOTAL SAMPLE: 20 3.0% 1.0•/. 2.0% 3.0 CLIENT NO.: LM- B-007 LM -B-008 - LM -B-009 LM -B-010 LM -B-011 PART B PART C PART A PART I) PART B ASBESTIFORM MINERAL FIBERS: CHRYSOTILE 025% AMOSTIE ND CROCIDOLITE ND TREMOLTTE-ACTINOLITE ND ANTHOPHYLLTTE ND TOTAL ASBESTOS COUNTED 0.25% TOTAL ASBESTOS IN LAYER 0.25% TOTAL ASBESTOS IN SAMPLE 0.01% NOTES: SAMPLES NO. I - 5 ARE WHITE DRYWALL MUD. ND - NONE DETECTED NO TOTAL ASBESTOS IN LAYER = TOTAL ASBESTOS IN SAMPLE = DEFINITIONS 0.501/o 0.75% 0.251/. 0.75% ND ND ND ND ND ND ND ND ND ND ND ND ND ND NO ND 0.50 0.75% 0.25% 0.75% 0.50% 0.75% 0.25% 0.75% 0.02% 0.01% 0.01% 0.02°/. THE AMOUNT OF ASBESTOS PRESENT IN THE SAMPLE EXPRESSED AS A PERCENT. THE PERCENT OF SAMPLE REMAINING TARES ASBESTOS COUNTED EXPRESSED AS A PERCENT. THE PERCENT OF TOTAL SAMPLE (FROM PLM/SM ANALYSIS) TIMES T41E TOTAL ASBESTOS IN LAYER (IF NO ASBESTOS IN OTHER LAYERS). DCM SCIENCE LABORATORY, INC. 12421 W. 49TH AVENUE, UNIT #6 WHEAT RIDGE, CO 80033 (303) 463 -8270 BULK ASBESTOS ANALYSIS - POINT COUNT METHOD PAGE 3 OF 4 CLIENT. ANALYSIS DATE: 8 -31-06 A&D ASBESTOS TESTING REPORTING DATE: 8 -31-06 653 361/4 ROAD RECEIPT DATE: 8_28-06 PALISADE, CO 81526 CLIENT JOB NO.: THE LANDMARK PROJECT TITLE: 610 W. LIONSHEAD CR. - VAIL DCMSL PROJECT: ADATM CROSS REFERENCE. ADA7289 PERCENTAGE COMPOSITION BY AREA/VOLUME DCM LAB NO.: -11 -12 ' -13 -14 SAMPLE DATE: 8 -22-06 8 -22-06 8 -22 -06 8 -22-06 % OF TOTAL SAMPLE: 3.0% 1.0 1.0 7.0% " CLIE TTNO.: LM -B-017 LM -B-018 LM -B -019 LM -B-020 PART B PART A PART A PART C ASBESTIFORM MINERAL FIBERS: CHRYSOTILE 0,75% 1.00 1.75% 0.50'/0 AMOSTTE ND ND ND NO CROCIDOLITE NO ND ND . ND TREMOLITE- ACTINOLITE ND ND NO ND ANTHOPHYLLITE ND ND ND ND TOTAL ASBESTOS COUNTED 0.75% 1.00 1.75% 0.50 TOTAL ASBESTOS IN LAYER 0.75% 1.00% 1.75% 0.50% TOTAL ASBESTOS IN SAMPLE 0.02% 0.01% 0.02% 0.04% NOTES: SAMPLES NO. 11 -14 ARE WHITE DRYWALL MUD. ND - NONE DETECTED DEFINITION TOTAL ASBESTOS COUNTED = THE AMOUNT OF ASBESTOS PRESENT IN THE SAMPLE EXPRESSED AS A PERCENT. TOTAL ASBESTOS IN LAYER = THE PERCENT OF SAMPLE REMAINING TIMES ASBESTOS COUNTED EXPRESSED AS A PERCENT. TOTAL ASBESTOS IN SAMPLE = THE PERCENT OF TOTAL SAMPLE (FROM PLM/SM ANALYSIS) TIMES THE TOTAL ASBESTOS IN LAYER (IF NO ASBESTOS IN OTHER LAYERS). • • 0.50 0.50%. 0.25% 0.75% 0.75% DCM SCIENCE LABORATORY, INC. ND ND ND ND ND 12421 W. 49TH AVENUE, UNIT #6 ND ND ND ND ND WHEAT RIDGE, CO 80033 (303) 463 -8270 ND ND ND ND ND BULK ASBESTOS ANALYSIS - POINT COUNT METHOD ND ND ND ND PAGE 2 OF 4 TOTAL ASBESTOS COUNTED 0.50 0.50 0.25 0.75% CLIENT-. ANALYSIS DATE: 8 -31-06 0.50% 0.50' /e 015% 0.75% A&D ASBESTOS TESTING REPORTING DATE: 8 -31-06 0.01°x6 0.02% 0.01% 0.02% 653 361/4 ROAD RECEIPT DATE: 8 -28-06 DRYWALL MUD. PALISADE, CO 81526 CLIENT JOB NO.: THE LANDMARK PROJECT TITLE: 610 W. LIONSHEAD CIL - VAIL DCMSL PROJECT: ADAT290 TOTAL ASBESTOS - COUNTED = CROSS REFERENCE: ADA1789 PERCENTAGE COMPOSITION BY AREANOLUME TOTAL ASBESTOS IN LAYER DCM LAB NO.: -6 7 -8 -9 -10 SAMPLE DATE: 9-22-06 8 -22-06 8-22-06 8- 22-06 8 -22-06 % OF TOTAL SAMPLE: 2.0% 4.0% 4.0 3.0 2.0' /s CLIENTNO.: LM -8-012 LM -B -013 UA -B-014 LM -13 LM &016 PART B PART B PART B PART B PART B ASBESTIFORM MINERAL FIBERS: CHRYSOIT LE 0.50 0.50%. 0.25% 0.75% 0.75% AMOSTIE ND ND ND ND ND CRObDOLITE ND ND ND ND ND TREMOL ITE- ACTINOLITE ND ND ND ND ND ANTHOPHYLLITE ND ND ND ND ND TOTAL ASBESTOS COUNTED 0.50 0.50 0.25 0.75% 0.75% TOTAL ASBESTOS IN LAYER 0.50% 0.50' /e 015% 0.75% 0.75% TOTAL. ASBESTOS IN SAMPLE 0.01°x6 0.02% 0.01% 0.02% 0.02%s NOTES. SAMPLES NO.6 -10 ARE WHITE DRYWALL MUD. ND - NONE DETECTED D EFINITION S TOTAL ASBESTOS - COUNTED = THE AMOUNT OF ASBESTOS PRESENT IN THE SAMPLE E PRESSED AS A PERCENT. TOTAL ASBESTOS IN LAYER THE PERCENT OF SAMPLE REMAINING TIMES ASBESTOS COUNTED EXPRESSED AS A PERCENT. TOTAL ASBESTOS IN SAMPLE = THE PERCENT OF TOTAL SAMPLE (FROM PLMISM ANALYSIS) TIMES THE TOTAL ASBESTOS IN LAYER (IF NO ASBESTOS IN OTHER LAYERS). DCM Science Laboratory, Inc. 12421 W. 49th Avenue, Unit #6 Wheat Ridge, CO 80033 DCM Project No- ADAT 290 (:Neat Job No- THE LANDMARK Quantitative Bulk Sample Analysis (Point Count) QUANTITATIVE BULK SAMPLE ANALYSIS PROCEDURES: PW q orA DCM Science Laboratory, Inc. analyzes bulk samples in accordance with the National Emission Standard for Hazardous Air Pollutants (NESHAP) for asbestos (Federal Register, Vol. 55, No. 224, pp. 48406. 48433, 11!20/90). The analytical procedures followed are described In 'Interim Method for the Determination of Asbestos in Bulk insulation Samples ", (USEPA 600/M483 -020, 1982), with minor modifications recommended by the Atmospheric Research and Exposure Assessment Laboratory, USEPA, Research Triangle Park, N.C. Samples analyzed by the point count method are milted to homogenize the sample, prepared on microscope slides and point counted using polarized light microscopy (PLM) in conjunction with a point counting stage and counter. One hundred counts are performed on four separate preparations of each sample for a total of 400 points.. If asbestos is identified but not counted during the point counting procedure, total asbestos is reported as zero and presence is noted on the report Other preparation procedures including ashing and acid washing may be performed with client permission to improve accuracy in det mining asbestos concentration. All samples are archived for six months unless other arrangements are made by the client. ACCREDITATION: DCMSL is accredited by the AIHA (since 1986). Our laboratory number is 101526. DCMSL is accredited by NVLAP (since April 1, 1989). DCMSL complies with NVLAP and AIHA requirements unless otherwise noted. ENDORSEMENT: The results of this analysis must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government. This test report relates only to the items bested. This report may not be reproduced except in full, without the written approval of the laboratory. The analysis was performed by: John Silverman, Analyst Ron Schott, Analyst Ron Schott Laboratory Director RVaAf NVW code 101258 DCM Science Laboratory, Inc. .12421 W. 49th Avenue, Unit #6 Wheat Ridge, CO 80033. DCM Proied No.: ADAT 289 Cft t Job No.: THE LANDMARK Bulk Sample Analysis BULK SAMPLE ANALYSIS PROCEDURES: Page _5 . _ of 1 5 DCM Science Laboratory, Inc. analyzes bulk asbestos samples following procedures developed by the McCrone Research Institute and in compriance with guidelines established by the Environmental Protecpon Agency (EPA -600/R- 931116, July, 1993). Bulk samples are prepared for analysis using a 10X -80X stereo microscope in a hepa filter hood which provides a contamination -free environment. The sample is then analyzed by polarized light microscopy (PLM) at 100X. When the sample consists of more than one layer, each layer is prepared and analyzed separately. Fiber and matrix materials are identified by the characterization of optical properties including color and pleochrorism, fomh, clea vage, relief;: birefringence, extinction, orientation, twinning, interflerence figure and other distinguishing other fibers n s fius��ents are calculated from the valuuees�ob�tained from the s� and as bestos, PLM microscopes analysis. In -house and NIST standards as well as a chart prepared by R.D. Terry and G.V. Chilinger for "The Journal of Sedimentary PetrokV, (Volume 24, pp. 229 - 234,1955) provide a guide for clien esti ating percentages. All samples are archived for sox months unless other arrangements are made by the ACCREDITATION: DCMSL is accredited by NVLAp (since April 1, 1989). Our NVLAP Lab Code is 101258 -0. DCMSL complies with NVLAP requirements unless otherwise noted. ENDORSEMENT: The results of this analysis must not be used by the client to claim endorsement by NVLAP or any agency of the U.S. Government. This best report relates only to the items tested. This report may not be reproduced except in full, without the written approval of the laboratory. The analysis was performed by: A�" John Sherman, Am" Ron ScIwtt, Analyst Ron Schott R-0? 0 Laboratory Director Deft 0r\n NVLAP Lab Code lo125" A & D Asbestos; Testing and Consulting t John R. Peterman P.O. Box 1230 Clifton, CO. 81520 -1230 Cell 970- 270 -36$9 Home Phone 970- 464 -5265 August 26; 2006 To: Destination Resorts The LandMark 610 W. Lionshead Circle Vail, CO. 81657 Attn: Geoff Wright RE: Asbestos inspection and testing at The LandMark, 610 W. LionsHead Circle, Vail, CO. 81657 Qtv. Description Cost 20 — Bulk Samples (3 to 5 daj turn around) @ $45 each $900.00 14 — Point Count Analysis (3 5 days) @ $45 each 630.00 1 � i _ have i a (a t" M �} Aav AM M Due and Payable upon - Thank you for your business �I 1 �Tm -O(ZA 12 -11 -2009 Inspection Request Reporting Page 5 4:00 pm Vail, CO - City Of Requested Inspect Date: Monday, December 14, 2009 Inspection Area: JRM Site Address: 610 W LIONSHEAD CIR VAIL UNIT 18, LANDMARK A/P /D Information Activity: B09 -0076 Type: A -MF Const Type: Occupancyy: Owner: VANDERHOUT, JAMES H. & PATRICIA A. Contractor: ALTER DESIGN BUILDERS LLC Description: INTERIOR REMODEL & ADDITION (UNIT 18) Requested Inspectionls Item: 90 BLDG -Final Requestor: ALTER DESIGN BUILDERS LLC Comments: 390 -2037 Assigned : Action: CG p. Time Ex Comment: SS NOT INSTALLE Item: 2 DOOR HARDWARE NOT INSTALLED 3 HANDRAIL AT LOWER STAIR MISSING Comment: CANCELLED BY CONTRACTOR Comment: APPROVED FOR TCO. \/INSTALL SHOWER GLASS FOR FINAL CO. lnvF Ftm \t, (r0 Inspection History Item: 226 FIRE DEPT. NOTIFICATION Item: 30 BLDG - Framing 10/08/09 Inspector: c Comment: 1) DRYWALL CALL IN FOR SHOV BOTTOM PLATE MI NAIL PLATE AT MC FIRESTOP WITH IN SEAL FIRE SPRINK Sub Type: AMF Use: IIIA Phone: 476 -4033 Status: ISSUED Insp Area: JRM Requested Time: 03:00 PM Phone: 970 - 476 -4033 -or- 847 -345- 4104 Howard's c Entered By: JMONDRAGON K Action: CR CORRECTION REQUIRED AT TOP PLATE AT BATHROOM CEILING =R VALVE ROUGH -IN SING AT TOILET AND BACK SIDE OF WALL 'ABLE CMU WALL IN MASTER BATH ULATION AT DROPPED CEILINGS UPSTAIRS WHERE MISSING =R LINE PENETRATION AT TOP PLATE UPSTAIRS ,TER LINES DOWNSTAIRS E- INSPECT ITEMS AT INSULATION INSPECTION Item: 50 BLDG - Insulation ** A proved ** 10/09/09 Inspector: MAN Action: AP APPROVED Comment: - CALL FOR SHOWER VALVE RE- INSPECTION Item: 60 BLDG - Sheetrock Nail ** Approved ** 10/15/09 Inspector: cg Action: NR NOT READY FOR INSPECTION Comment: 10/16/09 Inspector: BW Action: AP APPROVED Comment: Item: 70 BLDG -Misc. Item: 90 BLDG -Final ** Approved ** 11/25/09 Inspector: CG Action: CR CORRECTION REQUIRED Comment: 1 SHOWER GLASS NOT INSTALLED 2 DOOR HARDWARE NOT INSTALLED 3 HANDRAIL AT LOWER STAIR MISSING 11/27/09 Inspector: CG Action: NR NOT READY FOR INSPECTION Comment: CANCELLED BY CONTRACTOR 11/30/09 Inspector: CG Action: PA PARTIAL APPROVAL Comment: APPROVED FOR REPT131 Run Id: 10753