HomeMy WebLinkAboutB09-0076NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MEOFVK
.•
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
ADD /ALT MF BUILD PERMIT
Job Address: 610 W LIONSHEAD CIR VAIL
Location......: UNIT 18, LANDMARK
Parcel No....: 210106307018
OWNER VANDERHOUT, JAMES H. & PATRI 05/04/2009
9450 N REGENT CT
MILWAUKEE
WI 53217
APPLICANT ALTER DESIGN BUILDERS LLC 05/04/2009 Phone: 476 -4033
5500 W. HOWARD ST.
SKOKIE
IL 60077
License: 352 -A
CONTRACTOR ALTER DESIGN BUILDERS LLC 05/04/2009 Phone: 476 -4033
5500 W. HOWARD ST.
SKOKIE
IL 60077
License: 352 -A
Description:
INTERIOR REMODEL & ADDITION (UNIT 18)
Occupancy: R -2
Type Construction: I I IA
Permit #:
B09 -0076
Project #:
PRJ09 -0128
Status .. :
ISSUED
Applied ..:
05/04/2009
Issued...:
07/22/2009
Expires ...:
01/18/2010
Valuation: $60,000.00
Total Sq Ft Added: 152
..................................,.......,,.,,,,, ...<.,....,..,...............,. FEE SUMMARY ...............................,,.......,,...... ....,,......,.,........,..,....
Building Permit Fee - - - - -> $713.75 Will Cal Fee---------- - - - - -> $4.00 Total Calculated Fees------ - - - - -> $2,333.69
Plan Check -- -------- - - ---> $463.94 Use Tax Fee ------ ---- ------ > $1,000.00 Additional Fees -- ------- ---- - - - - -> $0.00
Add'I Plan Check Hours- $0.00 Restuarant Plan Review - - - - -> $0.00 TOTAL PERMIT FEES -------- ----- > $2,333.69
Investigation -------- — ------- > $0.00 Recreation Fee -------- -- ----- > $152.00
Payments- - - - - -- - ---- -> $2,333.69
Total Calculated Fees--- - - - - -> $2,333.69 BALANCE DUE — ---- ----- - - - - -> $0.00
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information
as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure
according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto. It
REQUESTS FOR INSPECTION S
4:00 PM.
Signature OH ner or
Print Nam
-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
Date
bid — a It construction _perm it_041908
************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
TOWN OF VAIL, COLORADO Statement
*************************************************************
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Statement Number:
R090000890 Amount: $2,333.69 07/22/200902:55 PM
Payment Method:
Check Init: JLE
Notation: 41857 ALTER
DESIGN BUILDERS
-----------------------------------------------------------------------------
Permit No:
B09 -0076 Type: ADD /ALT MF BUILD PERMIT
Parcel No:
2101 - 063 - 0701 -8
Site Address:
610 W LIONSHEAD CIR VAIL
Location:
UNIT 18, LANDMARK
Total Fees: $2,333.69
This Payment:
$2,333.69 Total ALL Pmts: $2,333.69
Balance: $0.00
*************************************************************
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
ACCOUNT ITEM LIST:
Account Code
--------------
Description Current Pmts
- - -
BP 00100003111100
- -- ----- ------------------- - - - - -- ------ - - - - --
BUILDING PERMIT FEES 713.75
PF 00100003112300
PLAN CHECK FEES 463.94
RF 11100003112700
RECREATION FEES 152.00
UT 11000003106000
USE TAX 4% 1,000.00
WC 00100003112800
WILL CALL INSPECTION FEE 4.00
Separate permits are required for electrical, plumbing, mechanical, fireplace, etc.
Project Street Address:
610 West Lionshead Circle Unit 18
(Number) (Street) (Suite #)
Building/Complex Name: The Landmark Condominiums
Contractor Information:
Company: Alter Design Builders
Company Address: 5500 W. Howard St.
Office Use:
Project #: �J �
DRB #: ` r 0 + ��
Buildi Permit #: ��lJ
Lot #J_ Subdivision:
Detailed Description of Work: Interior Renovation of
City: Skokie State: IL Zip: 60077 West Tower Unit 18 with added bath & flex space.
Contact Name: Howard Olsen
Contact Phone: 970 476 -4033
@ 9 P• ,
E - Mail holsen alter rou com (use additional sheet if necessary)
t
Work Class:
Town of V Con ctor Registration No.: 352 -A
New ( ) Addition ( ) Remodel Repair ( ) Other ( )
Work Type
Cont ctor Signature (requ red) Interior ) Exterior ( ) Both ( )
Property Information
Parcel #: 210106307018
(For parcel #, contact Eagle County Assessors Office at 970- 32 "64Q or
visit www.eaglecouty.us/patie)
Tenant Name:
Owner Name: James Vanderhout
Valuations (Labor & Material))
Building:
$
$30,000.00
Plumbing:
$
$8,000.00
Electrical:
$
$16,000.00
Mechanical:
$
$6,000.00
Total:
$
$60,000.00
Type of Building:
Single - Family ( ) Duplex ( ) Multi - Family (� )
Commercial( ) Other( )
Does a Fire Alarm Exist? Yes( No( )
Monitored Alarm? Yes (r) No( )
Does a Sprinkler System Exist? Yes(. No( )
IN MOG
# & Type of Existing Fireplaces: Gas Appliances 1
Gas Log Wood /Pellet Wood Burning
# & Type of Proposed Fireplaces: Gas Appliances 1
Gas Log Wood /Pellet Wood Burning
Date Received:
D
�C� 0 �n
APR 3 0 2009
TOWN OF VAIL
BUILDING PERMIT APPLICATION
Town of Vail
OF Fi
VA0. FI/
OP
101 Vail Fire Department
Asbestos Testing & Abatement Requirements
Q�+cr ae
Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from
exposure to harmful asbestos. The Town of Vail asbestos abatement program is in addition to the State of Colorado's
regulations. It is your responsibility to be in compliance with the State. Please contact the State directly for their
requirements at the contact info listed below.
When is asbestos testing required?
ANY building projects disturbing more than these threshold levels of building materials require
asbestos testing:
One- and Two - Family Dwellings: 30 square feet
All Others: 160 square feet
Asbestos testing results must be provided with your application for a building permit.
Tests which identify POSITIVE results at more than 1 % require abatement by a State - certified
and Vail- registered abatement contractor. An asbestos abatement permit must be approved,
and the clearance letter must be submitted to the Town of Vail before the building permit will be
issued.
Project Checklist
My project falls into the category checked below:
❑ Will not disturb more than the threshold limits identified above
9 Tested negative, or at 1% or below (2 copies of test results included)
❑ Tested positive at more than 1 %, requires abatement (2 copies of test results
included
Tips & Facts:
• Even recent construction projects may include asbestos-containing materials, so buildings of any age
require testing.
• The "1989 Ban" on asbestos - containing materials is commonly misunderstood. "In fact, in 1991 the U.S.
Fifth Circuit Court of Appeals vacated much of the so- called "Asbestos Ban and Phaseout" rule and
remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation,
processing, or distribution in commerce of many asbestos - containing product categories was set aside and
did not take effect." - CDPHE
Asbestos test results and abatement permit applications should be submitted to: Town of Vail,
Community Development, 75 S Frontage Rd, Vail, CO, 81657.
Town of Vail Contact:
David Rhoades, Fire Inspector
Vail Fire Department
75 S Frontage Rd
drhoades @vailgov.com
970 -477 -3454
www.vailgov.com
State of Colorado Contact:
Colorado Department of Public Health
and Environment
Asbestos Compliance Assistance Group
303 -692 -3158
asbestos @state.co.us 2 \1�7
www.cdohe.state.co.us D V/
APR 3 01009
OF VAIL
Z flu , "i _rVI
i
. l
4
i
A & D Asbestos Testing and Consulting
John R. Peterman
P.O. Box 1230 Clifton, CO. 81520 -1230
Cell 970- 270 -3689 Home Phone 97OA64 -5265
INSPECTION REPORT PREPARED FOR:
Destination Resorts
610 W. LionsHead Circle
Vail, CO. 81657
LOCATION:
The LandMark
610 W. LionsHead Circle
Vail, CO. 81657
REPORT PREPARED BY:
John R. Peterman
Inspector Manager
Certificate No.. 6601
Town of Vail
OFFICE COPY
L�C�L OdL�
D r
APR 3 0 2009 �
2
TOWN OF VAIL
z
A & D Asbestos Testing and Consulting
John R. Peterman
Asbestos Testing, Project Design, and Consulting
INTRODUCTION:
On August 2211d, 2006, an inspection/survey was conducted and 20
bulk samples were collected from the:
The LandMark
610'W. LionsHead Circle
Vail, CO. 81657
The purpose of the inspection/survey was to locate and sample
suspected asbestos containing materials that might be present in the
Residence that is planned for demolition.
The inspection was made, and the samples were collected by John R.
Peterman, an A.H.E.R.A. and State of Colorado Certified Asbestos
Inspector. Great care was taken during the inspection and sampling to be as
accurate as possible. It should be noted that minimal damage was done to
the existing building structures during the inspection so there is no
documentation for unseen conditions or stored items.
All samples were analyzed by DCM Science Lab in Wheatridge, CO.
This laboratory is deemed `Proficient" in the E.P.A.Quality Assurance (QA)
program for the determination of asbestos in bulk materials, and is
accredited by the American Hygiene Association (AHA).
SAMPLING PROTOCOL:
A random sampling scheme was used to sample the suspect materi als that
were discovered. If during any future demolition or renovation work,
suspect material is discovered that hasn't been sampled and would be
disturbed, work should be halted until the material has been tested.
A & D Asbestos Testing and Consulting
John R. Peterman
AsbestosTesting, Project Design, and Consulting
The LandMark
610 W. LionsHead Circle
Vail, CO. 81657
MOLDING DESCRIPTION:
The LandMark consists of two multi -story buildings with a connecting
underground parking garage. The Tower Building is the east building with
seven stories, and a garage level. The Town House building has single level
units on the first floor, and loft units on the tip levels. This survey covers
the inside of the buildings. The interior walls are covered in sheetrock with
a light texture, and wood paneling. Note: In some areas a texture has been
troweled over the original finish. The ceilings are sheetrock with a heavy
spray -on texture, and twin tee concrete with the same spray -on texture. The
basement area has suspended ceiling tiles throughout, and most have been
replaced not long ago. The older tiles were tested in the Billy's Grill area.
The floors are covered with carpet, ceramic tiles, and sheet vinyl flooring.
The sheet vinyl was not tested in this survey. The heating is provided by
baseboard heating, and fireplaces. No suspect thermal system insulation was
observed during this inspection. The garage ceiling had a spray -on fire
proofing that was mostly removed prior to this inspection.
CONCLUSIONS AND RECOMMENDATIONS:
Presumed Asbestos containing materials, present in the buildings, are as
follows:
1. Spray -on ceiling texture
2. Sheet vinyl flooring
3. Exterior siding board
4
A & D Asbestos Testing and Consulting
John R. Peterman
AsbestosTesting, Project Design, and Consulting
Laboratory Analysis of the bulk samples collected during this inspection
indicate that Asbestos was detected in all of the composite sheetrock
samples. However, the Asbestos content is less than the Regulatory Limit
(Greater than 1 % Asbestos). The Asbestos content of the samples was
verified by the Required Point Count Analysis. The samples collected were
taken from the original areas of the buildings. If conditions are encountered
that are not the original construction, additional testing or documentation
may be required. H the renovation work will impact on the three presumed
Asbestos containing materials listed, the P.A.C.M. must be handled as per
Colo. Reg. #8 prior to disturbance of the materials.
5
r
W
J
a 000200 00000000000000
W W W W W W zz z z Z Z Z Z Z Z Z Z Z Z
3 3 3 3 3 3 3 3 3 3 3 3 3
alOJila YYYYYicMM X J9jC.YY
c c : 0 00 0
L
g L L
z Q 8S88i��8 r8o
0 a E o ttr cstr.c rttr
Y. Y. {L 0 0 0 0. 0 0 0 AM O O co N 0 0 0
a c c cr-f = 1= = = I 8a� �r� S �$ L
Q M N w ' 5 0 0 a N a* a
to 0 i.Zae C co CL 9L ILC LCCCCC
m co — =HEEEEEEEEEEEEEE
o v v � L3�3 38 80 0 3 80 0 So o Q 3c3
6
U +,
> o V o 000 o
g 0 V rJ
0
cc
�o` �"$��r�..E� EE Y
U. s`•o o N gvB �•
V W �.�� VVmVVVVV O 0013 pa.
0 �u = == o f E E E E E M
11 v N
B e t e 9 0ZMW b ECG
!: M
lu mmm i1m M o mm a �E: 0 1
Q W _ '_ m wm a p 6 1 6c �
J " =m mm3ui5W'X i3 a.a a�sm a
d a a ��O�pp�OO�NNOM��jjr10 OwNin
O N o O NaaaV
40 lu .-_�333�33�3w33333
o w o o 0 0 0 0 0 0 0 0 0 0 0 0 0 0
` z a DOt'i ..tip!•- i�F- i- 1- F- F+f- 1- F -1-F -F
a O m
N c M l7 Yf [� O O r N @7 w 40 n CD W O
O 7T *' *-
T' T r r r
C' g $oSg3$oa00000c000
++ m 0 Z
lu
IM= W a mmmmmmmmmmmmmmmmmmmm
(f1 JJJJJJJ J JJJJJ -IJJ
rNl9�! 1A t�t�aDp 0 rNOfd tAfG1��DfAO
D J C!
V- V- V- r r r r r r V-
N
° o- ° o�$g ° oo�oog000 N OO�ao�
O
a
� a
a c
Q
O m c
p O
V O c
i- I
c=iza
W
a
to
ZZZ ZZwmw ��wccIEIc g
co
W
xxssxxsssxsxss
000000 00 0000
to
r
a
cc
O
U
_w
m
_L
x
U
J wF H�
C C C 9 G
3 3 3 3 3 3 11 3 3 3 3 3
=
co M0 YYYYYYYYYYYY YY
C C G 0 0000000000
Al. -b 2s ..
00 8
C
J
Z
_O
'Q- �SII:I
� rrrrrrrrr .crrr
!It wcacc NN01NNNN NN
d
0 � 0 0 0 0 0 0
R H MMEE NN p IC
C C
c c as C.. a aaaa
p E p E o EEEE o EE4 o E p EE p E
v * 88 )VC7SS0
m
02
H
cc
m
r- W P QrNORW t0ID�aOOO
O r6V r V T rt - rq
i l i l
cl
o O o
0 0 0 COMM 0 0 00 0
N
Z
ai
3
3G
0
W
a.
mmmmmmmmmmmmmmmmmmmm
. . . - . • f . . . . . .
Q
a
N
J J J J J J J J J J J J J J J J J
-i -i -i
D J
(/�
- N rr�- rm�r�N
Y
a
� a
a c
Q
O m c
p O
V O c
i- I
c=iza
E
9L
c
so
zzzzzzzzzzzzzzzzzzzz
s�
_ c
0 33333333333333333333
am °A°q9 °O 00J0000000000
N
a
me
c
33333333333333333333
00000000000000000J00
O
cA
V
m
v
C�
�q
333 = = =sxsxxrxxx
000
�
� �
JJJ��'� =Sx xxzSSx =xxss
O
c
V o
N N N N N N N N W co N yy to N N N N N N N
WIi1WWWWWWWWWW WWWWWWW
} } } } } }
X
vi
} } } } } }'y. } } } } }}
i
CD a
^
FM
Q
om
0
L
N =
T ' c � c � O y �q ^��O*'NNRIDfOhdOC10
J
(�
3
��5o25 8g000000000000�
N
z
m
Q.
mmmmmmmmmmmmmmmmmmmm
N
r r r r r r r r r r r r r r r r r• r• }
�
E„�
JJJJJJJ JJJJ J1 Y
J
QI
rN Pfd 1p�ptiQpO V W tOPaD0�0
r yr r r r r r r N
r
L
O
O
2
W
v
Q
a
0
U .
W }��aaaaaaaaaaaaaaaaa
IL aa33�z33333333333333
°O$O ° oSS ° o S ° o ° oSgo o SSS o o ° oS
� SS$oc000000c00000000
T T T
0
W
a 000 00000000000000000
4 }w}zzzzzzzzzzzz.zzzzz
a
0
r�
m
z
O_
r
t
0
0
O
0
U
v
w
_
�
J
J
a
�QOGOCGCGOGGCCQ�GGOGGG
_
00000000000000000000
lu
00000000000000000000
o.advv vvvvv vaaa vvvvvv
v
O
V
v
c
Z
W
�a
�
w
J
0
�acor vvvat¢o�¢QOC¢acmoco�¢¢ac
1-
Y
O -0
N.
W
m
/iY� � Q
O O T T T T p
T T� T v- (V
G7 v S
z
b
W
3
to
U
IL
mmmmmmmmmmmmmmmmmmmm
a O
W
Q
• • • • • • • • • 4 • • • • • • • • • • •
W
rat j
iA .'�Ars.' j -J i-i �� iAj-i
J J J J J J J J J J J J J J J Y
w
- NO�•poD1�e00aOTNlhst•Amt�a
0 J
T T T T T T T T T T N
N
s
e
z = v
a
1. 2 k
Go Go -d
Q y
fA
I
w o 0 0 00 00 0o g000 00000
<� S 9 g 99 s$ 98 8999 89999
y O O O p O O p O O p O O p O 1 O pq O� p O p O W? C?
tp N ON O ON 89 g8gog '
Wb
oz
q q q qo 00 oq oggo ogooy
a g �, o h °$ d o dog 0008
t � U
O
c � 3 _
H
go
O 00 00 OO R8
00
c $ooA z
�0%
ena �a Na NNE! a ...�vi-
3 a w0
o �
N a OD OO
Mn
00 N N N
00 Op 00
qO 00
r
a
V
��z
O CS $ g g o - $ - $ - - $ o $ - S - S g g $
E,U
S
0000 C? C? 0000 0000 C C?
ao ° a ga ° a 8� ° 0 $°tco+ good
z
zzo
U
h y o000 0000 000
O x
O
O .
rA
o
No S.
�N��o
ppGG
o o o N
ob O C4 O 0
V taCaUagj
.�n C7 N••m .-.NN Nin viq .. tV �G
N sr N N
a0
a
o n
O Z o A aA a A a o
.g A <aRUA <c�UA t
0 < GD Ci A
e
�o
� , H
y 00
F� ao
f/ o 8
m
<�a
p 0 0 0 O O O o O p O O o O O O O O O p O O
8888 C1 888 8888 8888 8885
0 LLLFFFRRRsss � .
p ohoo C! C! p on0o hoop
m O SO OO SO� C,m g8Oq
R
W F .
ox
z�
h �N o000 0000 0000 0000 0000
.�+ O GO$N CCgN OOON oO8N 000eV
8 � w C GG
� z
N
�3
�z o�
G�
1 o
10 0
� w �
[�
P� w
�
3 p Qe � .-1 bSC4 �i�io3oS� $08� oo�i
C4� evm%o� .-•C4V Nm�c� ...N7m
<
oo] 3 3
,$ O aA Aq�gA�QQO�Q A�
F N
h O oD 00 co
h i 00
V
<e 2 ,
a .�
oq
a
w
z °O �
CIO
Q Wmm0. !!
V � N
- � z
� � V
U W
Na
O Oe oD OD l" b
<aH
2 5 y
` qc7 <ai c �w
8 0 Wo 0. z
�a�
H
a
0.
F
s
U
v
b
A b
.
A
a
0 0 0 0 0 0 0 0
8988 8898
0C! oov►o
�$�a gQaa
I o 0 0 0 0 0 0 0
O C o N O y O N
9 e
U
OO
9
C
R�-
�R1UA
�ctgUA
�
Z
4
b .
q a
d1
a
o
w
E
DCM SCIENCE LABORATORY, INC.
025%
AMOSTIE
12421 W. 49TH AVENUE, UNIT #6
CROCIDOLITE
ND
WHEAT RIDGE, CO 80033 (303) 463 -8270
ND
ANTHOPHYLLTTE
BULK ASBESTOS ANALYSIS - POINT COUNT METHOD
TOTAL ASBESTOS COUNTED
PAGE I OF 4
TOTAL ASBESTOS IN LAYER
0.25%
CLIENT: ANALYSIS DATE:
8 -31-06
NOTES: SAMPLES NO. I - 5 ARE WHITE DRYWALL MUD.
A&D ASBESTOS TESTING REPORTING DATE:
8 -31-06
ND
653 36 1/4 ROAD RECEIPT DATE:
8 -28-06
0.25%
PALISADE, CO 81526 CLIENT JOB NO.:
THE LANDMARK
0.75%
PROJECT TITLE.
610 W. LIONSHEAD CR. - VAIL
DCMSL PROJECT:
ADAl290
0.01%
CROSS REFERENCE:
ADA1789
PERCENTAGE COMPOSITION BY AREA/VOLUME
DCM LAB NO.: -1 -2 -3
-4
-5
SAMPLE DATE: 8 -22-06 8 -22-06 8 -22-06
8- 22-06
8 -22-06
% OF TOTAL SAMPLE: 20 3.0% 1.0•/.
2.0%
3.0
CLIENT NO.: LM- B-007 LM -B-008 - LM -B-009
LM -B-010
LM -B-011
PART B PART C PART A
PART I)
PART B
ASBESTIFORM MINERAL FIBERS:
CHRYSOTILE
025%
AMOSTIE
ND
CROCIDOLITE
ND
TREMOLTTE-ACTINOLITE
ND
ANTHOPHYLLTTE
ND
TOTAL ASBESTOS COUNTED
0.25%
TOTAL ASBESTOS IN LAYER
0.25%
TOTAL ASBESTOS IN SAMPLE
0.01%
NOTES: SAMPLES NO. I - 5 ARE WHITE DRYWALL MUD.
ND - NONE DETECTED
NO
TOTAL ASBESTOS IN LAYER =
TOTAL ASBESTOS IN SAMPLE =
DEFINITIONS
0.501/o
0.75%
0.251/.
0.75%
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
NO
ND
0.50
0.75%
0.25%
0.75%
0.50%
0.75%
0.25%
0.75%
0.02%
0.01%
0.01%
0.02°/.
THE AMOUNT OF ASBESTOS PRESENT IN THE SAMPLE EXPRESSED
AS A PERCENT.
THE PERCENT OF SAMPLE REMAINING TARES ASBESTOS COUNTED
EXPRESSED AS A PERCENT.
THE PERCENT OF TOTAL SAMPLE (FROM PLM/SM ANALYSIS)
TIMES T41E TOTAL ASBESTOS IN LAYER (IF NO ASBESTOS IN
OTHER LAYERS).
DCM SCIENCE LABORATORY, INC.
12421 W. 49TH AVENUE, UNIT #6
WHEAT RIDGE, CO 80033 (303) 463 -8270
BULK ASBESTOS ANALYSIS - POINT COUNT METHOD
PAGE 3 OF 4
CLIENT.
ANALYSIS DATE: 8 -31-06
A&D ASBESTOS TESTING
REPORTING DATE: 8 -31-06
653 361/4 ROAD
RECEIPT DATE: 8_28-06
PALISADE, CO 81526
CLIENT JOB NO.: THE LANDMARK
PROJECT TITLE: 610 W. LIONSHEAD CR. - VAIL
DCMSL PROJECT: ADATM
CROSS REFERENCE. ADA7289
PERCENTAGE COMPOSITION BY AREA/VOLUME
DCM LAB NO.:
-11 -12 ' -13 -14
SAMPLE DATE: 8 -22-06 8 -22-06 8 -22 -06 8 -22-06
% OF TOTAL SAMPLE: 3.0% 1.0 1.0 7.0% "
CLIE TTNO.:
LM -B-017 LM -B-018 LM -B -019 LM -B-020
PART B PART A PART A PART C
ASBESTIFORM MINERAL FIBERS:
CHRYSOTILE
0,75% 1.00 1.75% 0.50'/0
AMOSTTE
ND ND ND NO
CROCIDOLITE
NO ND ND . ND
TREMOLITE- ACTINOLITE
ND ND NO ND
ANTHOPHYLLITE
ND ND ND ND
TOTAL ASBESTOS COUNTED
0.75% 1.00 1.75% 0.50
TOTAL ASBESTOS IN LAYER
0.75% 1.00% 1.75% 0.50%
TOTAL ASBESTOS IN SAMPLE
0.02% 0.01% 0.02% 0.04%
NOTES: SAMPLES NO. 11 -14 ARE WHITE DRYWALL MUD.
ND - NONE DETECTED
DEFINITION
TOTAL ASBESTOS COUNTED =
THE AMOUNT OF ASBESTOS PRESENT IN THE SAMPLE EXPRESSED
AS A PERCENT.
TOTAL ASBESTOS IN LAYER =
THE PERCENT OF SAMPLE REMAINING TIMES ASBESTOS COUNTED
EXPRESSED AS A PERCENT.
TOTAL ASBESTOS IN SAMPLE =
THE PERCENT OF TOTAL SAMPLE (FROM PLM/SM ANALYSIS)
TIMES THE TOTAL ASBESTOS IN LAYER (IF NO ASBESTOS IN
OTHER LAYERS).
• •
0.50 0.50%. 0.25% 0.75%
0.75%
DCM SCIENCE LABORATORY, INC.
ND ND ND ND
ND
12421 W. 49TH AVENUE, UNIT #6
ND ND ND ND
ND
WHEAT RIDGE, CO 80033 (303) 463 -8270
ND ND ND ND
ND
BULK ASBESTOS ANALYSIS - POINT COUNT METHOD
ND ND ND ND
PAGE 2 OF 4
TOTAL ASBESTOS COUNTED
0.50 0.50 0.25 0.75%
CLIENT-. ANALYSIS DATE:
8 -31-06
0.50% 0.50' /e 015% 0.75%
A&D ASBESTOS TESTING REPORTING DATE:
8 -31-06
0.01°x6 0.02% 0.01% 0.02%
653 361/4 ROAD RECEIPT DATE:
8 -28-06
DRYWALL MUD.
PALISADE, CO 81526 CLIENT JOB NO.:
THE LANDMARK
PROJECT TITLE:
610 W. LIONSHEAD CIL - VAIL
DCMSL PROJECT:
ADAT290
TOTAL ASBESTOS - COUNTED =
CROSS REFERENCE:
ADA1789
PERCENTAGE COMPOSITION BY AREANOLUME
TOTAL ASBESTOS IN LAYER
DCM LAB NO.: -6 7 -8
-9
-10
SAMPLE DATE: 9-22-06 8 -22-06 8-22-06
8- 22-06
8 -22-06
% OF TOTAL SAMPLE: 2.0% 4.0% 4.0
3.0
2.0' /s
CLIENTNO.: LM -8-012 LM -B -013 UA -B-014
LM -13
LM &016
PART B PART B PART B
PART B
PART B
ASBESTIFORM MINERAL FIBERS:
CHRYSOIT LE
0.50 0.50%. 0.25% 0.75%
0.75%
AMOSTIE
ND ND ND ND
ND
CRObDOLITE
ND ND ND ND
ND
TREMOL ITE- ACTINOLITE
ND ND ND ND
ND
ANTHOPHYLLITE
ND ND ND ND
ND
TOTAL ASBESTOS COUNTED
0.50 0.50 0.25 0.75%
0.75%
TOTAL ASBESTOS IN LAYER
0.50% 0.50' /e 015% 0.75%
0.75%
TOTAL. ASBESTOS IN SAMPLE
0.01°x6 0.02% 0.01% 0.02%
0.02%s
NOTES. SAMPLES NO.6 -10 ARE WHITE
DRYWALL MUD.
ND - NONE DETECTED
D EFINITION S
TOTAL ASBESTOS - COUNTED =
THE AMOUNT OF ASBESTOS PRESENT IN THE SAMPLE E PRESSED
AS A PERCENT.
TOTAL ASBESTOS IN LAYER
THE PERCENT OF SAMPLE REMAINING TIMES ASBESTOS COUNTED
EXPRESSED AS A PERCENT.
TOTAL ASBESTOS IN SAMPLE =
THE PERCENT OF TOTAL SAMPLE (FROM PLMISM ANALYSIS)
TIMES THE TOTAL ASBESTOS IN LAYER (IF NO ASBESTOS IN
OTHER LAYERS).
DCM Science Laboratory, Inc.
12421 W. 49th Avenue, Unit #6
Wheat Ridge, CO 80033
DCM Project No- ADAT 290
(:Neat Job No- THE LANDMARK
Quantitative Bulk Sample Analysis (Point Count)
QUANTITATIVE BULK SAMPLE ANALYSIS PROCEDURES:
PW q orA
DCM Science Laboratory, Inc. analyzes bulk samples in accordance with the National Emission Standard for
Hazardous Air Pollutants (NESHAP) for asbestos (Federal Register, Vol. 55, No. 224, pp. 48406. 48433,
11!20/90). The analytical procedures followed are described In 'Interim Method for the Determination of
Asbestos in Bulk insulation Samples ", (USEPA 600/M483 -020, 1982), with minor modifications recommended
by the Atmospheric Research and Exposure Assessment Laboratory, USEPA, Research Triangle Park, N.C.
Samples analyzed by the point count method are milted to homogenize the sample, prepared on microscope
slides and point counted using polarized light microscopy (PLM) in conjunction with a point counting stage and
counter. One hundred counts are performed on four separate preparations of each sample for a total of 400
points.. If asbestos is identified but not counted during the point counting procedure, total asbestos is reported
as zero and presence is noted on the report Other preparation procedures including ashing and acid washing
may be performed with client permission to improve accuracy in det mining asbestos concentration. All
samples are archived for six months unless other arrangements are made by the client.
ACCREDITATION:
DCMSL is accredited by the AIHA (since 1986). Our laboratory number is 101526. DCMSL is accredited by
NVLAP (since April 1, 1989). DCMSL complies with NVLAP and AIHA requirements unless otherwise noted.
ENDORSEMENT:
The results of this analysis must not be used by the client to claim endorsement by NVLAP or any agency of the
U.S. Government.
This test report relates only to the items bested. This report may not be reproduced except in full, without the
written approval of the laboratory. The analysis was performed by:
John Silverman, Analyst Ron Schott, Analyst
Ron Schott
Laboratory Director
RVaAf
NVW code 101258
DCM Science Laboratory, Inc.
.12421 W. 49th Avenue, Unit #6
Wheat Ridge, CO 80033.
DCM Proied No.: ADAT 289
Cft t Job No.: THE LANDMARK
Bulk Sample Analysis
BULK SAMPLE ANALYSIS PROCEDURES:
Page _5 . _ of 1 5
DCM Science Laboratory, Inc. analyzes bulk asbestos samples following procedures developed by the
McCrone Research Institute and in compriance with guidelines established by the Environmental Protecpon
Agency (EPA -600/R- 931116, July, 1993).
Bulk samples are prepared for analysis using a 10X -80X stereo microscope in a hepa filter hood which provides
a contamination -free environment. The sample is then analyzed by polarized light microscopy (PLM) at 100X.
When the sample consists of more than one layer, each layer is prepared and analyzed separately. Fiber and
matrix materials are identified by the characterization of optical properties including color and pleochrorism,
fomh, clea vage, relief;: birefringence, extinction, orientation, twinning, interflerence figure and other distinguishing
other fibers n s fius��ents are calculated from the valuuees�ob�tained from the s� and as bestos,
PLM
microscopes analysis. In -house and NIST standards as well as a chart prepared by R.D. Terry and G.V.
Chilinger for "The Journal of Sedimentary PetrokV, (Volume 24, pp. 229 - 234,1955) provide a guide for
clien
esti ating percentages. All samples are archived for sox months unless other arrangements are made by the
ACCREDITATION:
DCMSL is accredited by NVLAp (since April 1, 1989). Our NVLAP Lab Code is 101258 -0. DCMSL complies
with NVLAP requirements unless otherwise noted.
ENDORSEMENT:
The results of this analysis must not be used by the client to claim endorsement by NVLAP or any agency of the
U.S. Government.
This best report relates only to the items tested. This report may not be reproduced except in full, without the
written approval of the laboratory. The analysis was performed by:
A�"
John Sherman, Am" Ron ScIwtt, Analyst
Ron Schott R-0? 0
Laboratory Director Deft
0r\n
NVLAP Lab Code lo125"
A & D Asbestos; Testing and Consulting
t
John R. Peterman
P.O. Box 1230 Clifton, CO. 81520 -1230
Cell 970- 270 -36$9 Home Phone 970- 464 -5265
August 26; 2006
To: Destination Resorts
The LandMark
610 W. Lionshead Circle
Vail, CO. 81657
Attn: Geoff Wright
RE: Asbestos inspection and testing at The LandMark, 610 W. LionsHead
Circle, Vail, CO. 81657
Qtv. Description Cost
20 — Bulk Samples (3 to 5 daj turn around) @ $45 each $900.00
14 — Point Count Analysis (3 5 days) @ $45 each 630.00
1 �
i _ have i a (a t" M �} Aav AM M
Due and Payable upon
- Thank you for your business
�I
1
�Tm -O(ZA
12 -11 -2009 Inspection Request Reporting Page 5
4:00 pm Vail, CO - City Of
Requested Inspect Date: Monday, December 14, 2009
Inspection Area: JRM
Site Address: 610 W LIONSHEAD CIR VAIL
UNIT 18, LANDMARK
A/P /D Information
Activity: B09 -0076 Type: A -MF
Const Type: Occupancyy:
Owner: VANDERHOUT, JAMES H. & PATRICIA A.
Contractor: ALTER DESIGN BUILDERS LLC
Description: INTERIOR REMODEL & ADDITION (UNIT 18)
Requested Inspectionls
Item:
90 BLDG -Final
Requestor:
ALTER DESIGN BUILDERS LLC
Comments:
390 -2037
Assigned :
Action:
CG p.
Time Ex
Comment:
SS NOT INSTALLE
Item:
2 DOOR HARDWARE NOT INSTALLED
3 HANDRAIL AT LOWER STAIR MISSING
Comment:
CANCELLED BY CONTRACTOR
Comment:
APPROVED FOR TCO.
\/INSTALL SHOWER GLASS FOR FINAL CO.
lnvF
Ftm \t, (r0
Inspection History
Item: 226 FIRE DEPT. NOTIFICATION
Item: 30 BLDG - Framing
10/08/09 Inspector: c
Comment: 1) DRYWALL
CALL IN FOR SHOV
BOTTOM PLATE MI
NAIL PLATE AT MC
FIRESTOP WITH IN
SEAL FIRE SPRINK
Sub Type: AMF
Use: IIIA
Phone: 476 -4033
Status: ISSUED
Insp Area: JRM
Requested Time: 03:00 PM
Phone: 970 - 476 -4033 -or- 847 -345-
4104 Howard's c
Entered By: JMONDRAGON K
Action: CR CORRECTION REQUIRED
AT TOP PLATE AT BATHROOM CEILING
=R VALVE ROUGH -IN
SING AT TOILET AND BACK SIDE OF WALL
'ABLE CMU WALL IN MASTER BATH
ULATION AT DROPPED CEILINGS UPSTAIRS WHERE MISSING
=R LINE PENETRATION AT TOP PLATE UPSTAIRS
,TER LINES DOWNSTAIRS
E- INSPECT ITEMS AT INSULATION INSPECTION
Item:
50 BLDG - Insulation ** A proved **
10/09/09
Inspector: MAN Action:
AP APPROVED
Comment:
- CALL FOR SHOWER VALVE RE- INSPECTION
Item:
60 BLDG - Sheetrock Nail ** Approved **
10/15/09
Inspector: cg Action:
NR NOT READY FOR INSPECTION
Comment:
10/16/09
Inspector: BW Action:
AP APPROVED
Comment:
Item:
70 BLDG -Misc.
Item:
90 BLDG -Final
** Approved **
11/25/09
Inspector: CG Action:
CR CORRECTION REQUIRED
Comment:
1 SHOWER GLASS NOT INSTALLED
2 DOOR HARDWARE NOT INSTALLED
3 HANDRAIL AT LOWER STAIR MISSING
11/27/09
Inspector: CG Action:
NR NOT READY FOR INSPECTION
Comment:
CANCELLED BY CONTRACTOR
11/30/09
Inspector: CG Action:
PA PARTIAL APPROVAL
Comment:
APPROVED FOR
REPT131 Run Id: 10753