Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B11-0051
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES M 1 Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11 -0051 Job Address: 1776 GORE CREEK DR VAIL Location......: Parcel No....: 210312307001 OWNER SMITH, HORACE J., III & PATR 04/05/2011 1776 GORE CREEK DR VAIL CO 81657 APPLICANT SRE BUILDERS, INC. 04/05/2011 Phone: (970) 845 -6359 PO BOX 6376 VAIL COLORADO 81658 License: 360 -A CONTRACTOR SRE BUILDERS, INC. 04/05/2011 Phone: (970) 845 -6359 PO BOX 6376 VAIL COLORADO 81658 License: 360 -A Description: REPLACE THREE EXTERIOR WINDOWS, TWO EXTERIOR DOORS. ADD TWO FAM VENT TERMINATIONS AND ONE DRYER VENT TERMINATION. WINDOWS TO MATCH EXISTING. MECHANICAL TERMINATION TO BE COLOR OF SIDING. Occupancy: Type Construction: Project #: Applied.....: Issued... PRJ 11 -0085 04/05/2011 05/11/2011 Valuation: $70,000.00 ..........................................««... ................. «.,....,...... FEE SUMMARY ,.,,,.........................,.... w........... ...,...................,....... Building Permit ------ - - - - -> $783.75 Bldg Plan Check ----- - - - - -> $509.44 Use Tax Fee------------------ - - - - -> $1,200.00 Electrical Permit ---- - - - - -> $172.50 Elec Plan Check ------ - - - - -> $112.13 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $20.00 Mech Plan Check ---- - - - - -> $5.00 Additional Fees--------------- - - - - -> $0.00 Plumbing Permit --- - - - - -> $255.00 Plmb Plan Check ---- - - - - -> $63.75 Recreation Fee--------------- - - - - -> $0.00 Investigation------------------ - - - - -> $0.00 Will Call ------------------------------ > $20.00 TOTAL PERMIT FEES -- ----------- > $3,141.57 Payments -- ---------------------------- > $3,141.57 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state 18ws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - PM. 1q) l Sjgn*ure of O_ ner or Contractor Date combination permit_012811 CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11 -0051 Owner: SMITH, HORACE J., III & PATRICIA A. combination permit_012811 Address: 1776 GORE CREEK DR VAIL Location: A OVAIWN REQUIRED INSPECTIONS AND STATUSES Permit #: B11 -0051 Owner: SMITH, HORACE J., III & PATRICIA A. Address: 1776 GORE CREEK DR VAIL Location: Item: 00534 PLAN - FINAL C/O Item: 00090 BLDG -Final combination permit_012811 TOWN OF VAIL, COLORADO Statement Statement Number: R110000449 Amount: $2,632.13 05/11/201103:00 PM Payment Method:Credit Crd Init: SAB Notation: VISA - SRE BUILDERS ----------------------------------------------------------------------------- Permit No: Bll -0051 Type: COMBINATION BLDG PERMIT Parcel No: 2103 -123- 0700 -1 Site Address: 1776 GORE CREEK DR VAIL Location: Total Fees: $3,141.57 This Payment: $2,632.13 Total ALL Pmts: $3,141.57 Balance: $0.00 ACCOUNT ITEM LIST: Account Code -------------- Description Current Pmts - - - - -- BP 00100003111100 ------------------------ - - - - -- ------ - - - - -- BUILDING PERMIT FEES 783.75 EP 00100003111100 ELECTRICAL PERMIT FEES 172.50 MP 00100003111100 MECHANICAL PERMIT FEES 20.00 PF 00100003112300 PLAN CHECK FEES 180.88 PP 00100003111100 PLUMBING PERMIT FEES 255.00 UT 11000003106000 USE TAX 4% 1,200.00 WC 00100003112800 WILL CALL INSPECTION FEE 20.00 DS Consulting, Inc. Final Clearance Air Monitoring Report 1776 Gore Creek Dr., Vail, CO 81657 Presented To: Mr. Richard Capra Rocky Mountain Abatement, Inc P.O. Box 621840 Littleton, CO 80162 -1840 Performed & Prepared By: Mr. David Sinkbeil DS Consulting, Inc. 5366 Flatrock Ct Morrison, CO 80465 (720) 201 -6611 Project Details: Project Number: 4045 Conducted: May 5, 2011 EXECUTIVE SUMMARY On May 5, 2011, Mr. David Sinkbeil with DS Consulting, Inc. (DSC) conducted a final visual inspection, performed aggressive clearance air monitoring, and analyzed clearance air - quality samples via Phase Contrast Microscopy (PCM) for an asbestos abatement project at the residence located at Gore Creek Dr., Vail, Colorado. Services were provided at the request of Mr. Richard Capra with Rocky Mountain Abatement in support of asbestos abatement activities being conducted to remove approximately 500ft2 of asbestos - containing drywall and approximately 30ft2 of sheet vinyl from a full containment encompassing a portion of the upper level and main level of the residence. Monitoring locations and frequencies were determined by Mr. David Sinkbeil; having EPA and State of Colorado accreditation No. 13015. PCM analysis was also performed by Mr. Sinkbeil (see Appendix B for certifications). DSC's scope of work for this project included performing a final visual inspection and collection and analysis of aggressive final air quality samples by NIOSH 582 - trained personnel for determination of airborne asbestos (as total fibers) concentrations in identified areas. DSC is a participant in the Industrial Hygiene Proficiency Analytical Testing (IHPAT) program with laboratory ID No. 188987 and has a rating of Proficient. The abatement project passed the final visual inspection and the analytical results of all samples collected were below the clearance criteria of 0.01 fibers /cubic centimeter (f /cc) (see Appendix A for Air Sample Analysis). PROJECT INFORMATION • General Abatement Contractor (GAC) Rocky Mountain Abatement, Inc. • GAC Project Supervisor Mr. Juan Noriega • Project Location 1776 Gore Creek Dr., Vail, CO • Project Contact Mr. Richard Capra 2 • Air Monitoring Specialist /Analyst Mr. David Sinkbeil • Date Conducted May 5, 2011 • Final Clearance Sample Results See Appendix A • Certifications See Appendix B PROJECT INTRODUCTION On May 5, 2011, Mr. David Sinkbeil with DS Consulting, Inc. (DSC) conducted a final visual inspection, performed aggressive clearance air monitoring, and analyzed clearance air - quality samples via Phase Contrast Microscopy (PCM) for an asbestos abatement project at the residence located at 1776 Gore Creek Dr., Vail, Colorado. Services were provided at the request of Mr. Richard Capra with Rocky Mountain Abatement in support of asbestos abatement activities being conducted to remove approximately 500ft2 of asbestos - containing drywall and 30ft2 of sheet vinyl from a full containment encompassing a portion of the upper level and main level of the residence. Monitoring locations and frequencies were determined by Mr. David Sinkbeil; having EPA and State of Colorado accreditation No. 13015. PCM analysis was also performed by Mr. Sinkbeil (see Appendix B for certifications). SCOPE OF WORK DSC's scope of work for this project included performing a final visual inspection and collection and analysis of aggressive final air quality samples by NIOSH 582 - trained personnel for determination of airborne asbestos (as total fibers) concentrations in identified areas. DSC is a participant in the Industrial Hygiene Proficiency Analytical Testing (IHPAT) program with laboratory ID No. 188987 and has a rating of Proficient. The abatement project passed the final visual inspection and the analytical results of all samples collected were below the clearance criteria of 0.01 fibers /cubic centimeter (f /cc) (see Appendix A for Air Sample Analysis). AIR MONITORING Air - quality samples were collected utilizing a modified NIOSH 7400 Method, whereby samples were collected on 25- millimeter (mm) mixed - cellulose, ester - membrane filters with 0.45- micron pore size and analyzed via Phase Contrast Microscopy (PCM) as per the customer's requirements. Sample Collection - PCM samples, when applicable, were collected on 25- millimeter (mm) mixed - cellulose, ester - membrane filters with 0.45- micron pore size with an effective collection area of 385 mm. All filters were pre- assembled by the manufacturer in three stages, conductive sampling cassettes with extension cowls. Air samples were collected at an average flow rate 13.0 liters per minute (L /m) using Thomas high - volume pumps with a minimum of 1,200 liters being collected. Flow rates were collected at the beginning and at the end of the sampling period utilizing an airflow rotameter calibrated against a primary -flow calibration instrument. Start times and stop times were recorded for all sampling periods. A field blank and lab blank were also collected and analyzed along with the five (5) clearance samples. PCM Sample Analysis Method - PCM samples were analyzed according to a modified NIOSH 7400 Method —A Counting Rules — although samples were collected on 25 -mm mixed - cellulose, ester - membrane filters with 0.45- micron pore size and analyzed via PCM. Air sample results contained in this report have been calculated with blank sample corrections. 3 APPENDIX A — AIR SAMPLE RESULTS Sample CL-1 Pump �- Hi vol. Sample Downstairs Kitchen Area Avg. 13.0 Start 5:01 Stop 6:36p Time 95 Vol. 1235 J"Ults Fibers 9.0/100 0.003 CL -2 Hi vol. Downstairs Kitchen Area 13.0 5:02 6:37p 95 1235 7.0/100 0.003 CL -3 Hi vol. Downstairs Hallway 13.0 5:03 6:38p 95 1235 8.5/100 0.003 CL -4 Hi vol. Upstairs Bedroom 13.0 5:04 6:39p 95 1235 11/100 0.004 CL -5 Hi vol. Upstairs Bedroom 13.0 5:05 6:40p 95 1235 9/100 0.003 CL -lb n a I Lab Blank I n a I n a I n a n a n a 1 0/100 0.000 CL -fb n a I Field Blank I n a I n a I n a n a n a 1 0/100 0.000 APPENDIX B CERTIFICATIONS STATE OF COLORADO ASBESTOS w } CERTIFICATION* Colorado Department of Public Health and Environment Air Pollution Control Division This certifies that David Sinkbeil Certification No: 13015 f = has met the requirements of -7 -507, C.R.S. and Air Quality Control Commission Regulation Igo. 8, Part B, and is hereby certified by the state of Colorado in the following discipline: Air Monitoring Specialist* Issued: 7125/2410 Expires on: 7 {5 {241 Auifirarized PCa Representative # This eedykafc is raalid only wi#r ske possession of a current Divisiom-appy wed rrOning course rerfTiiraiiam in the discipline specified above. � A /iY d f"Clli/�6G fL L iGSI Training & CO 2761 West Oxford Avenue 47 Englewood, Colorado 80 1. 10 303 781 -0422 CERTIFIES THAT DAVID SINKBEIL has successfully completed THE NIOSH 582 EQUIVALENT COURSE SAMPLING &EVALUATING AIRBORNE ASBESTOS DUS r - e: 06/20 - 06124/05 rs a 40 d: 06124/05 No.: D0062405 - 11 Ile Aotr " , 0 ex, - ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Statement Number: R110000259 Amount: $509.44 04/05/201111:53 AM Payment Method:Credit Crd Init: DR Notation: VISA SARAH WYSCARVER (SRE) ----------------------------------------------------------------------------- Permit No: B11 -0051 Type: COMBINATION BLDG PERMIT Parcel No: 2103 - 123 - 0700 -1 Site Address: 1776 GORE CREEK DR VAIL Location: Total Fees: $3,141.57 This Payment: $509.44 Total ALL Pmts: $509.44 Balance: $2,632.13 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- PF 00100003112300 PLAN CHECK FEES 509.44 TOWN OF VAIL CON DEU 75 S FRONTAGE RD, VAIL, CO 81657 970- 479-2324 TERMINAL I.D.: 2002 MERCHANT H: VISA 0*0*00045251 SALE BATCH: 000240 I NU : 000001 AUTH:526454 APR O4, 11 12:53 TOTAL 1509.44 CUSTOMER COPY Department, of Community Development 'p 75 South Frontage Road Vail, Colorado 81657 Tel: 970 - 479 -2128 r" Web: www.vailgov.com Development . Mi " a, I BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: 1776 Gore Creek Drive (Number) (Street) (Suite #) Building /Complex Name: Contractor Information Business Name: SRE Builders, Inc. Business Address: 23698 US Hwy 24 #D -2 City Minturn State: CO Zip: 81645 Contact Name: Sarah Contact Phone: 970- 845 -6359 Contact E -Mail: sarah@srebuilders.com Contractor Registration Number: 360A n X q. ) \, Owner /O er's Ypiesentative Signature (Required) Project Information Owner Name: Parcel #: 2103- 123 -07 -001 (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit www.eaglecounty.us/patie) Project #: PR l -DDS 5 DRB #: 'Di,,? �I ► I %�� C� Building Permit #: Lot #: Block # Subdivision: Work Class: New ( ) Addition ( ) Alteration ( / ) Type of Building: Single - Family (✓) Duplex ( ) Multi - Family ( ) Commercial( ) Other( ) Work Type: Interior (✓ ) Exterior ( ) Both ( ) Valuation of Work Included Plans Included Work Electrical (vo )Yes ( )No ( ,/)Yes ( )No 500 Mechanical (V )Yes ( )No Yes (✓)No 500 Plumbing (vo Yes ( )No )Yes ( 1O�No 17,000 Building (,/)Yes ( )No (,/)Yes ( )No 52,000 Value of all work being performed: $ 70,000 (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage 1Q,3 c3 0 Detailed Scope and Location of Work: Remodel of kitchen & (2) bathrooms (use additional sheet if necessary) For Office Use Only: ' I Fee Paid: 6 504.4{`1 Received From: SR2RN U. (6 PC-- BLUR. Cash Check # CC: (,Ts 87J MC Last 4 CC # tISQ 5 exp date: Auth #5 q SNOW L0%1Sc.AR.vE-2 !' Date Received: APR o a 2011 roll FF V�AI LL 01- Jan -I1 State of Colorado Asbestos Testing & Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testing required? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two - Family Dwellings: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Definition of a single - family dwelling: any dwelling unit that is used primarily for a single family, including multi - family /condominium units, and fractional fee units. Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State - certified abatement contractor. The air clearance letter or form must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My project falls into the category checked below: Will not disturb more than the threshold limits identified above. Tested negative, or at 1% or below (1 copies of test results included) XTested positive at more than 1 %, requires abatement (1 copies of test results included) i ips ac rac[s: • Even recent construction projects may include asbestos - containing materials, so buildings of any_ age require testing. • The "1989 Ban" on asbestos - containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so- called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos - containing product categories was set aside and did not take effect." - CDPHE Asbestos test results should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: Fire Prevention Bureau Vail Fire Department 75 S Frontage Rd Fire — i n spectors @va i Igov. com 970 -79 -2252 www.vailgov.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303 - 692 -3158 asbestos@state.co.us www.cdphe.state.co.us n I T.... t 1 DS Consulting, Inc. Asbestos Inspection and Sampling Report 1776 W Gore Creek Dr, Vail, Colorado 81657 Presented to: Mr. H.J. Smith Homeowner 1776 W Gore Creek Dr Vail, CO 81657 Performed & Prepared by: Mr. Steve Shurtliff DS Consulting, Inc. P.O. Box 6864 Avon,CO 81620 (303) 378 -1544 Project Details: DSC Project #: 2532 Conducted: July 23, 2010 t . Consulting EXECUTIVE SUMMARY On July 23, 2010, Mr. Steve Shurtliff of DS Consulting, Inc. (DSC) performed a limited inspection and collected asbestos bulk - samples at 1776 W Gore Creek Dr, Vail, Colorado, in order to identify potentially hazardous friable and non - friable asbestos - containing materials (ACM) within a portion of the above - referenced, single - family residence scheduled for renovations. The Colorado Department of Public Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos - containing material (ACM) as a material containing more than 1% asbestos. Mr. Shurtliff performed asbestos bulk - sampling of four (4) types of drywall texture (surfacing materials) in a total of twelve (12) locations within the main level kitchen, hallway and bathroom as well as the upper level bathroom. Mr. Shurtliff also performed asbestos bulk - sampling of vinyl flooring and resilient floor tile (miscellaneous materials) in a total of two (2) locations within the kitchen and kitchen closet. The bulk - samples were analyzed by Aerobiology Laboratory Associates, Inc. (NVLAP #200860 -0) in Denver, Colorado with the laboratory results of three (3) of the four (4) types of drywall being positive for asbestos greater than 1% Chrysotile. The bulk - samples of the vinyl flooring as well as the resilient floor tile collected from the kitchen were also positive for asbestos greater than 1% (see Appendix B for laboratory results). The bulk- samples of drywall collected from the main level bathroom were negative for asbestos. The following sampled materials were found to contain asbestos greater than 1% (ACM): *Quantities are approximations and subject to field verification. Sample Material Sample Material Friable/ Non- Estimated Quantities Material Asbestos ID Description Location Classification Condition Content Friable DW01 -01 Drywall Main Level Surfacing Friable <1,000ft2 Damaged 3% Chrysotile Kitchen Ceiling Material Upper Level Surfacing DW03 -03 Drywall Bathroom Material Friable <1,000ft z Damaged o 3% Chrysotile Ceiling DW04 -01 Drywall Main Level Surfacing Friable <1,000ft2 Damaged 4% Chrysotile Hallway Wall Material VF01 -01 Drywall Main Level Kitchen Floor Surfacing Material Friable 150ft2 Damaged 30% Chrysotile Main Level Surfacing FT01 -01 Drywall Kitchen Closet Material Friable +�- 50ft z Damaged o 3% Chrysotile Floor *Quantities are approximations and subject to field verification. PROJECT OVERVIEW I. Introduction A limited inspection and bulk - sampling for ACM was conducted at 1776 W Gore Creek Dr, Vail, Colorado, by Mr. Shurtliff on July 23, 2010, at the request of Mr. David Floyd with Floyd Custom Builders, LLC. Mr. Shurtliff is a Colorado State Certified Building Inspector; having EPA Accreditation #15413 (see Appendix A for certificate). The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non - friable ACM within portions of the residence scheduled for renovations. H. Structural Design The structure is a wood - framed, two- level, single- family residence. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk - sampling techniques. The asbestos bulk - sampling was conducted on suspect ACM with a limited number of bulk - samples being collected within the residence. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency / AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk - samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk - samples, representative of the suspect asbestos - containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if they exhibit similar physical characteristics and the application of the sampled material can be correlated to the application of un- sampled material. Bulk- samples collected were analyzed utilizing the EPA's Method for the Determination of Asbestos in Bulk Building Materials (EPA 600/R/116, July, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the bulk- samples was performed on the "date reported," as listed in the bulk - sample analysis report. IV. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: 1. Surfacing Material: sprayed or troweled onto structural building member. 2. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation. 3. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl /linoleum, ceiling tiles, insulation, and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged" are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered, water - stained, gouged, marred or otherwise abraded over less than one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: The surface is crumbling or blistered over at least one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). One -tenth (one - quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. Water stains, gouges, or mars are over at least one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. Response- action recommendations for asbestos - containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates the presence of asbestos greater than 1% within the bulk - sample, or a bulk - sample in the same HA, and should be addressed accordingly. A general recommendation indicates asbestos does not exist greater than 1% within the bulk - sample, or a bulk - sample in the same HA, and no further abatement activities are required for removal of the material. Any sample reporting a "TRACE" amount of asbestos must be considered to be positive for asbestos greater than 1% unless it is analyzed by the point -count method to be less than 1 %. V. Inspector Comments Asbestos was identified during the bulk - sampling conducted at 1776 W Gore Creek Dr, Vail, Colorado. A total of fourteen (14) bulk - samples were collected from the main level kitchen, hallway and bathroom as well as the upper level bathroom of the above - referenced residence. Five (5) bulk - samples tested positive greater than 1% for asbestos. ■ Asbestos was identified in the main level kitchen ceiling drywall (surfacing material) sample DW01 -01 at 3% Chrysotile ■ Asbestos was identified in the upper level bathroom ceiling drywall (surfacing material) sample DW03 -03 at 3% Chrysotile ■ Asbestos was identified in the main level hallway wall drywall (surfacing material) sample DW04- 01 at 4% Chrysotile ■ Asbestos was identified in the main level kitchen vinyl flooring (miscellaneous material) sample VF01 -01 at 30% Chrysotile • Asbestos was identified in the main level kitchen closet resilient floor tile (miscellaneous material) sample FT01 -01 at 3% Chrysotile VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent - asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. The following samples were collected from the single family residence at 1776 W Gore Creek Dr, Vail, Colorado, on July 23, 2010. The quantities are approximations and are subject to field verification: Homogeneous Area #01 Sample #: DW01 -01 Homogeneous Area #01 Sample #: DW01 -02 Sample Description: Drywall Sample Description: Drywall Sample Location: Main Level Kitchen Ceiling Sample Location: Main Level Kitchen Ceiling Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: <1,000ft2 Material Quantity: <1,000ft2 Material Condition: Damaged Material Condition: Damaged Physical Description (layers): White compound; White tan d all Physical Description (layers): n/a Asbestos Content (layers): 3% Chrysotile; Negative Asbestos Content (layers): n/a Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII 5 Homogeneous Area #01 Sample #: DW01 -03 Homogeneous Area #02 Sample #: DW02 -01 Sample Description: Drywall Sample Description: Drywall Sample Location: Main Level Kitchen Ceiling Sample Location: Main Level Bathroom Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: <1,000ft2 Material Quantity: <1,000ft2 Material Condition: Damaged Material Condition: Damaged Physical Description (layers): n/a Physical Description (layers): White tape; White /tan drywall; White texture w /white paint; White joint compound Asbestos Content (layers): n/a Asbestos Content (layers): Negative; Negative; Negative; Negative Recommendations: IMMEDIATE - See Section VII Recommendations: GENERAL - See Section VII Homogeneous Area #02 Homogeneous Area #02 Sample #: DW02 -02 Sample #: DW02 -03 Sample Description: Drywall Sample Description: Drywall Sample Location: Main Level Bathroom Ceiling Sample Location: Main Level Bathroom Ceiling Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: <1,000ft2 Material Quantity: <1,000ft2 Material Condition: Damaged Material Condition: Damaged Physical Description (layers): White /tan drywall; physical Description (layers): White tape; White White tape; White texture w /blue paint; White joint joint compound; White texture w /blue paint compound Asbestos Content (layers): Negative; Negative; Asbestos Content (layers): Negative; Negative; Negative; Negative Negative Recommendations: GENERAL - See Section VII Recommendations: GENERAL - See Section VII Homogeneous Area #03 Sample #: DW03 -01 Homogeneous Area #03 Sample #: DW03 -02 Sample Description: Drywall Sample Description: Drywall Sample Location: Upper Level Bathroom Ceiling Sample Location: Upper Level Bathroom Ceiling Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: <1,000ft2 Material Quantity: <1,000ft2 Material Condition: Damaged Material Condition: Damaged Physical Description (layers): Yellow fibrous woven; White texture w /white paint; White /tan drywall Physical Description (layers): Brown fibrous material; Yellow fibrous woven; White texture w white paint Asbestos Content (layers): Negative; Negative; Negative Asbestos Content (layers): Negative; Negative; Negative Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII Homogeneous Area #03 Homogeneous Area #04 Sample #: DW03 -03 Sample #: DW04 -01 Sample Description: Drywall Sample Description: Drywall Sample Location: Upper Level Bathroom Ceiling Sample Location: Main Level Hallway Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: <1,000ft2 Material Quantity: <1,000ft2 Material Condition: Damaged Material Condition: Damaged Physical Description (layers): Yellow fibrous physical Description (layers): Yellow mastic; Gold woven; White tape; White texture w /white paint; wall covering; White tape; White texture; White White texture w /white paint; White joint joint compound compound Asbestos Content (layers): Negative; Negative; Asbestos Content (layers): Negative; Negative; Negative; Negative; 3% Chr sotile Negative; 4% Ch sotile; 4% Chrysotile Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII Homogeneous Area #04 Sample #: DW04 -02 Homogeneous Area #04 Sample #: DW04 -03 Sample Description: Drywall Sample Description: Drywall Sample Location: Main Level Kitchen Wall Sample Location: Main Level Kitchen Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: <1,000f 2 Material Quantity: <1,OOOff2 Material Condition: Damaged Material Condition: Damaged Physical Description (layers): n/a Physical Description (layers): n/a Asbestos Content (layers): n/a Asbestos Content (layers): n/a Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII Homogeneous Area #05 Sample #: VFO1 -01 Homogeneous Area #06 Sample #: FT01 -01 Sample Description: Vinyl Flooring Sample Description: Resilient Floor Tile Sample Location: Main Level Kitchen Floor Sample Location: Main Level Kitchen Closet Floor Material Classification: Miscellaneous Material Material Classification: Miscellaneous Material Material Quantity: +/- 150ft2 Material Quantity. +/- 50ft2 Material Condition: Damaged Material Condition: Damaged Physical Description (layers): White sheet vinyl w /white fibrous backing; White sheet vinyl w tan fibrous backing physical Description (layers): Black mastic; Brown tile Asbestos Content (layers): Negative; 30% Chrysotile Asbestos Content (layers): Negative; 3% Chrysotile Recommendations: IMMEDIATE - See Section VII Recommendations: IMMEDIATE - See Section VII VII. Recommendations IMMEDIATE: The laboratory results of the potential ACM sampled at 1776 W Gore Creek Dr, Vail, Colorado, on July 23, 2010, indicate that five (5) bulk - samples of drywall, vinyl flooring and resilient floor tile collected from the residence were reported as positive for asbestos at 3% - 30% Chrysotile. If the above - referenced ACM is to be removed from the residence and the total quantity exceeds any of the regulatory trigger levels of 50 linear feet on pipes, 32 square feet on other surfaces, or the volume equivalent of a 55- gallon drum, a Colorado - licensed asbestos abatement contractor is required to perform the removal, including formal notification to the Colorado Department of Public Health and Environment prior to the abatement of the ACM. 8 APPENDIX A CERTIFICATION STATE OF COLORADO ASBESTOS CERTIFICATION* Colorado Department of Public Health and Environment Air Pollution Control Division This certifies that Steve Shurtliff Certification No: 15413 has met the requirements of 25-7-507, C.R.S. and Air Quality Control Commission Regulation No. S. Part B. and is hereby certified by the state of Colorado in the following discipline: Building Inspector* Issued: 6/12/2010 Expires on: 6/12/2011 tan Saco aepeserrubr. erll4e i hp-ed.be—. h d p—fl- bEAL FWAVM011110,141 LABORATORY ANALYSIS Z ACRObIO1OC1y LAbORATORy ASSOCIATES, iNCOr�rIATFI (UNSULIIN(, LAI30RAE:Y Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 www.aerobiolociv.net Client Name Street address DS Consulting, Inc. 5366 Flatrock Ct. LJ�I �Jr� Date Collected: LJ`1 uJ Date Received: 07/22/10 07/23/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/29/10 Attn: Steve Shurtliff #200860 -0 Date Reported: 07/29/10 Client Project Name: 1776 W. Gore Cr. Dr. Vail, CO Project ID: 105074 Client Lab Sample Number Job ID: Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA -600 /R- 93/116, July 1993. Paul Knappe Laboratory Analyst Page 1 of 5 Adam Humphreys Asbestos Laboratory Supervisor A = Amosite CELL = Cellulose Homo- Number Asbestos Detected Non - Asbestos Non - Fibrous Matrix Sample Identification Physical Description of Sample; Additional Comments geneous es/no of La ers % Fibers area % Material area % Material (composition) FT = Fibrous Talc Client Lab Sample Number POSITIVE 105074 -1A White Compound N 2,5% 3% CHRY 97 C DWOI -01 15% 105074 -1B White /Tan Drywall N 2,95% Negative CELL 85 G D WO 1 -02 105074 -2 PROGRESSIVE DWO 1 -03 105074 -3 PROGRESSIVE 98% 105074 -4A White Tape N 4.5% Negative CELL 2 15% 1050744B White /Tan Drywall N 4,10% Negative CELL 85 G DW02 -01 1050744C White Texture w/ White Paint N 4,25% Negative 100 C 105074 -41) White Joint Compound N 4,60% Negative 100 C 15% 105074 -5A White /Tan Drywall N 4.5% Negative CELL 85 G DW02 -02 98% 105074 -513 White Tape N 4,10% Negative CELL 2 Paul Knappe Laboratory Analyst Page 1 of 5 Adam Humphreys Asbestos Laboratory Supervisor A = Amosite CELL = Cellulose AC = Actinolite MW = Mineral Wool AN = Anthophyllite FBG = Fiberglass CHRY= Chrysotile SYN = Synthetic CR = Crocidolite WO = Wollastonite TR = Tremolite NTR = Non - Asbestiform TR Trace =Less Than 1% NAC = Non- Asbestiform AC FT = Fibrous Talc AH = Animal Hair 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 Q = Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T =Tar P = Perlite O = Organic B = Binder OP = Opaques D = Diatoms AERObIOIOgy LAbORATORy ASSOCIATES, INCORPORATED CONSULIINii LAOORAIOKY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 www.aerobioloay.net Client Name Street address DS Consulting, Inc. 5366 Flatrock Ct. IJ�1 Vt'�Js Date Collected: b Date Received 07/22/10 07/23/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/29/10 Attn: Steve Shurtliff #200860 -0 Date Reported: 07/29/10 Client Project Name: 1776 W. Gore Cr. Dr. Vail, CO Project ID: 105074 Negative AH = Animal Hair Job ID: C Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA- 600/R- 93/116, July 1993. S le Identification Physical Description of Sample; Additional Comments Homo- geneous es/no Number of La ers % Asbestos Detected Non-Asbestos Fibers area % Non - Fibrous Material area % Matrix M ri (composition) CR = Crocidolite C tent Lab Sam le Number DW02 -02 105074 -5C White Texture w/ Blue Paint N 4,35% Negative AH = Animal Hair 100 C 105074 -5D White Joint Compound N 4,50% Negative 100 C DW02 -03 105074 -6A White Tape N 3,5% Negative 98% CELL 2 105074 -6B White Joint Compound N 3,15% Negative 100 C 105074 -6C White Texture w/ Blue Paint N 3,800/0 Negative 100 C DW03 -01 105074 -7A Yellow Fibrous Woven N 3,5% Negative 98% FBG 2 105074 -7B White Texture w/ White Paint N 3,30% Negative 100 C 105074 -7C White/Tan Drywall N 3,65% Negative 15% CELL 85 G DW03 -02 105074 -8A Brown Fibrous Material N 3,2% Negative 98% CELL 2 105074 -8B Yellow Fibrous Woven N 33% Negative 98% FBG 2 Paul Knappe Laboratory Analyst Page 2 of 5 Adam Humphreys Asbestos Laboratory Supervisor A = Amosite CELL = Cellulose AC = Actinolite MW = Mineral Wool AN = Anthophyllite FBG = Fiberglass CHRY=Chrysotile SYN = Synthetic CR = Crocidolite WO = Wollastonite TR = Tremolite NTR = Non- Asbestiform TR Trace--Less Than 1% NAC = Non - Asbestiform AC FT = Fibrous Talc AH = Animal Hair 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 Q=Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T = Tar P = Perlite O = Organic B = Binder OP = Opaques D = Diatoms AERobiolOCly LAbORATORy -�--.� ASSOCIATES, INCORPORATED C UNSULIING UDUNAtUNY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 www.aerob1o1oay.net Client Name Street address DS Consulting, Inc.�n 5366 Flatrock Ct. = Date Collected: Date Received: 07/22/10 07/23/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/29/10 Attn: Steve Shurtliff #200860-0 Date Reported: 07/29/10 Client Project Name: 1776 W. Gore Cr. Dr. Vail, CO Project ID: 105074 Negative AH =Animal Hair Job ID: C Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA- 600/R- 93/116, July 1993. Sample Identification Physical Description of Sample; Additional Comments Homo- geneous (yes/no) Number of La ers % Asbestos Detected Non - Asbestos Fibers area % Non - Fibrous Material area % Matrix Material (composition) CR = Crocrdolite Client Lab Sample Number DW03 -02 105074 -8C White Texture w/ White Paint N 3,95% Negative AH =Animal Hair 100 C DW03 -03 105074 -9A Yellow Fibrous Woven N 5,2% Negative 98% FBG 2 105074 -913 White Tape N 5,5% Negative 98% CELL 2 105074 -9C White Texture w/ White Paint N 5,20% Negative 100 C 105074 -91) White Texture w/ White Paint N 5,35% Negative 100 C 105074 -9E White Joint Compound N 5,38% POSITIVE 3% CHRY 97 C D W04 -01 105074 -1OA Yellow Mastic N 5,5% Negative 100 105074 -1OB Gold Wall Covering N 5,5% Negative 90% CELL 10 105074 -IOC White Tape N 5,10% Negative 98% CELL 2 105074 -1OD White Texture N 5,40% POSITIVE 4% CHRY 96 C Paul Knappe Laboratory Analyst Page 3 of 5 Adam Humphreys Asbestos Laboratory Supervisor A = Amosite CELL = Cellulose AC = Actinolite MW = Mineral Wool AN = Anthophyllite FBG = Fiberglass CHRY=Chrysotile SYN = Synthetic CR = Crocrdolite WO = Wollastonite TR = Tremolite NTR = Non- Asbestiform TR Trace--Less Than 1% NAC = Non - Asbestiform AC FT = Fibrous Talc AH =Animal Hair 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 Q = Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T =Tar P = Perlite O = Organic B = Binder OP = Opaques D = Diatoms ACRObIO[OGy LAORATORy ASSOCwTEs, INCORPORATED CUNSULIING LAl30 I2AlCWY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.2323746 www.aerobioloov.net Client Name Street address DS Consulting, Inc. 5366 Flatrock Ct. r^ Date Collected: b uJ Date Received: � �� 07/22/10 07/23/10 City, State ZIP Morrison, CO 80465 Date Analyzed: 07/29/10 Attn: Steve Shurtliff #200860 -0 Date Reported: 07/29/10 Client Project Name: 1776 W. Gore Cr. Dr. Vail, CO Project ID: 105074 POSITIVE 4% CHRY AH =Animal Hair Job ID: C Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA - 600 /R- 93/116, July 1993. Sample Identification Physical Description of Sample; Additional Comments Homo- geneous es/no Number of La yers % Asbestos Detected Non- Asbestos Fibers area % Non- Fibrous Material area % Matrix Material (composition) CR = Crocidolite Client Lab Sample Number DW04 -01 105074 -IOE White Joint Compound N 5,40% POSITIVE 4% CHRY AH =Animal Hair 96 C DW04 -02 105074 -11 PROGRESSIVE D W 04 -03 105074 -12 PROGRESSIVE VFOI -01 105074 -13A White Sheet Vinyl w/ White Fibrous Backing N 2,50% Negative 30% CELL 70 B 105074 -13B White Sheet Vinyl w/ Tan Fibrous Backing N 2,50% POSITIVE 30% CHRY 5% CELL 65 B FTO 1 -0 1 105074 -14A Black Mastic N 2.1% Negative 100 B 105074 -14B Brown Tile N 2,99% POSITIVE 3% CHRY 97 Paul Knappe Laboratory Analyst Page 4 of 5 Adam Humphreys Asbestos Laboratory Supervisor A = Amosite CELL = Cellulose AC = Actinolite MW = Mineral Wool AN = Anthophyllite FBG = Fiberglass CHRY= Chrysotile SYN = Synthetic CR = Crocidolite WO = Wollastonite TR = Tremolite NTR = Non - Asbestiform TR Trace =Less Than 1% NAC = Non- Asbestiform AC FT = Fibrous Talc AH =Animal Hair 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 Q = Quartz C = Carbonates V = Vermiculite G = Gypsum M = Mica T =Tar P = Perlite O = Organic B = Binder OP = Opaques D = Diatoms AERObIO1OCjy LAbORATORy ASSOCIATES, INCORPORATED CONSH Tl %G I AHORAIORY Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 www.aerobiology.net DS Consulting, Inc 5366 Flatrock Ct. L Date Collected: p Date Received: �� 07/22/10 07123/10 Morrison, CO 80465 Date Analyzed: 07129/10 Steve Shurtliff #200860 -0 Date Reported: 07/29/10 Client Project Name: 1776 W. Gore Cr. Dr. Vail, CO Project ID: 105074 Job ID: General Notes ♦ Negative indicates no asbestos was detected; the method detection limit is 1 %. ♦ Trace or " <I" indicates asbestos was identified in the sample, but the concentration is less than the method detection limit of 1% ♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunterite. Crocidolite is the common name used for the asbestiform variety of the mineral reibekite. ♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods (e. g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi - quantitative bulk TEM floor tile analysis is accepted under the NESHAPS regulations. ♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted. ♦ Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days before discarding. A shipping and handling charge will be assessed for the return of any samples. Notes Required by NVLAPby NVLAP ♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. ♦ This test report relates only to the items tested or calibrated. ♦ This report is not valid unless it bears the name of a NVLAP- approved signatory. ♦ Any reproduction of this document must include the entire document in order for the report to be valid. 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 TOWN CC&SLA V0E%EL0PWN7 Design Review Board ACTION FORM Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2139 fax: 970.479.2452 web: www.vailgov.com Project Name: SMITH RESIDENCE REMODEL DRB Number: DRB110075 Project Description: REPLACE THREE EXTERIOR WINDOWS, TWO EXTERIOR DOORS. ADD TWO FAN VENT TERMINATIONS AND ONE DRYER VENT TERMINATION. WINDOWS TO MATCH EXISTING. MECHANICAL TERMINATION TO BE COLOR OF SIDING. Participants: OWNER SMITH, HORACE J., III & PATR 03/29/2011 1776 GORE CREEK DR VAIL CO 81657 APPLICANT SMITH, HORACE J., III & PATR 03/29/2011 1776 GORE CREEK DR VAIL CO 81657 Project Address: 1776 GORE CREEK DR VAIL Location: Legal Description: Lot: 29 Block: Subdivision: VAIL VILLAGE WEST FIL 1 Parcel Number: 2103 - 123 - 0700 -1 Comments: See conditions BOARD /STAFF ACTION Motion By: Action: STAFFAPP Second By: Vote: Date of Approval: 04/04/2011 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and /or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12 -3 -3: APPEALS. Cond:202 (PLAN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Cond: CON0011841 The applicant shall paint all mechanical vent terminations to match the exterior siding colors prior to requesting final planning inspections. Cond:CON0011842 The applicant shall paint the two red doors located on the second floor the Ebony satin color to be used on the two new first floor doors prior to requesting final planning inspections. Planner: Warren Campbell DRB Fee Paid: $20.00 KRMCONSULTANTS, INC. P.O. Box 4572 970 -945 -8891 Vail, Colorado 81 858 FAX 949-1577 FIELD REPORT Do 5 trx DATE: 5/10/2011 Tony - SRE ARRIVE: 3:45 DEPART: 4:15 WEATHER: CIrNVarm ATTENTION: 1170 JOB NUMBER: 1105-08 PROJECT: Gore Creek Remodel PRESENT AT SITE: Tony STATUS OF COMPLETION: N/A On May 10, 2011 1 visited the above referenced site to observe the moisture damage around the upper floor bathroom area. Some of the floor sheating had already been removed in this area at the time of the visit. I observed the 2x10 floor joists, rim joist, and wall studs in this area, and all contained moisture damage to some extent. I was able to penetrate each of these members with a screwdriver indicating excessive moisture damage. The damaged rim joist will need to be replaced along with about four adjacent floor joists, which have been damaged by moisture and /or excessive notching for plumbing. There were also at least a few studs above the rim that will need to be replaced /reinforced. Please do not hesitate to contact us with any questions. KRM Consultants, SIGNED: Tim D. Hennum, P REVIEWED: COPY TO: 07 -05 -2011 Inspection Request Reporting Page 3 _7:37 am Vail, CO =City pf Requested Inspect Date: Tuesdayy Julyy 05 2011 Site Address: 1776 G0�2E CREAK DR VAIL A/P /D Information Activity: 611 -0051 Type: COMBO Sub Type: ASFR Status: ISSUED Const Type: Occu ancyy: Use: Insp Area: Owner: SMITH, HORACE J., III & I�ATRICIA A. Contractor: SRE BUILDERS, INC. Phone: (970) 845 -6359 Description: REPLACE THREE EXTERIOR WINDOWS TWO EXTERIOR DOORS. ADD TWO FAM VENT TERMINATIONS AND ONE DRYER VENT 'TERMINATION. WINDOWS TO MATCH EXISTING. MECHANICAL TERMINATION TO BE COLOR OF SIDING. Item: 534 - FI C/O Requestor: SRE BUILD C. Comments: 471 - Assigned To: B SON Action: ` Time Exp: Item: 90 BLDG -Final Requestor: SRE BUILDERS, IN Comments: 471 -2107 Assigned To: J ON RAG N �© Action: Time Exp: _ Requested Time: 08:00 AM Phone: (9 50) 845 -6359 -or- cell 748 - Entered By: J64MOZNDRAGON K rated Time: 01:30 PM Phone: (45) 845 -6359 -or- cell 748 - Entered By: JMONDRAGON K Item: 290 PLMB -Final Requested Time: 11:30 AM Requestor: SRE BUILDERS, INC. Phone: (45) 845 -6359 -or- cell 748 - 6 z Comments: 471 -2107 Assigned To: J AGON Entered By: JMONDRAGON K Action: Time Exp: Item: 390 MECH -Final Requested Time: 01:00 PM Requestor: SRE BUILDERS, INC. Phone: (450) 845 -6359 -or- cell 748 - 6 Comments: 471 -2107 Assigned To: J AGON Entered By: JMONDRAGON K Action: Time Exp: K, Item: 190 ELEC -Final Requested Time: 08:00 AM Requestor: SRE BUILDERS, INC. Phone: (450) 845 -6359 -or- cell 748 - 6 Z Comments: 471 -210 Assigned To: ER Entered By: JMONDRAGON K Action: 3 Time Exp: le, oIF57, S Inspection History 40, REPT131 Run Id: 13300 Z-(a qq � 7 07 -07 -2011 Inspection Request Reporting Page 8 Lf 4:35 pm Vail, CO - City Of Requested Inspect Date: Friday, July 08, 2011 Site Address: 1776 GORE CREEK DR VAIL A /P /D Information Activity: B11 -0051 Type: COMBO Sub Type: ASFR Status: ISSUED Const Type: Occuppancyy Use: Insp Area. Owner: SMITH, HORACE J., III & PATRICIA A. Contractor: SRE BUILDERS, INC. Phone: (970) 845 -6359 Description: REPLACE THREE EXTERIOR WINDOWS, TWO EXTERIOR DOORS. ADD TWO FAM VENT TERMINATIONS AND ONE DRYER VENT TERMINATION. WINDOWS TO MATCH EXISTING. MECHANICAL TERMINATION TO BE COLOR OF SIDING. Requested Inspection(s) Item: 90 BLDG -Final Requestor: SIRE BUILDERS, IN Comments: 390 -5776 Assigned To: Action: Time Exp: Comment: Planning to sign off Requested Time: 10:00 AM Phone: 970 845 -6359 -or- cell 748- 45 Entered By: JMONDRAGON K Item: 534 PLAN -FINAL C/O Requested Time: 09:15 AM Requestor: SIRE BUILDERS, INC. Phone: (970) 845 -6359 -or- cell 748- 6452 Comments: 390 -5776 Assigned To: BGIBSON Entered By: JMONDRAGON K Action: Time Exp: Comment: Mechanical ven ing needs to be painte�tch the exterior facade material color. r o0 Inspection History Item: 534 PLAN -FINAL C/O 07/05/11 Inspector: Warren Action: DN DENIED Comment: Mechanical venting needs to be painted to match the exterior facade material color. Item: 120 ELEC -Rou h ** Approved ** 05/19/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 190 ELEC -Final ** Approved ** 07/05/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 30 BLDG - Framing ** Approved ** 05/23/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH -Rough ** Approved ** 07/05/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 220 PLMB - Rough /D.W.V. ** Approved ** 05/23/1 T Inspector: sgremmer Action: AP APPROVED Comment: Item: 230 PLMB- Rough/Water ** Approved ** 05/23/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 290 PLMB -Final ** Approved ** 07/05/11 Inspector: sgremmer Action: AP APPROVED Comment: Item: 390 MECH -Final "* Approved ** REPT131 Run Id: 13307