Loading...
HomeMy WebLinkAboutB11-0060NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES moona . Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11 -0060 Project #: Job Address: 595 VAIL VALLEY DR VAIL Location......: MANOR VAIL LODGE UNIT 470 Parcel No....: 210108122013 OWNER GMORE PH S.A. DE C.V. 04/08/2011 RIO DE LAS PLATA 407 OTE COLONIA DEL VALLE SAN PEDRO GARZA GARCIA N.L. MEXICO 66220 APPLICANT BECK BUILDING COMPANY P.O. BOX 4030 VAIL CO 81658 License: 117 -A CONTRACTOR BECK BUILDING COMPANY P.O. BOX 4030 VAIL CO 81658 License: 117 -A 04/08/2011 Phone: 970-949-1800 04/08/2011 Phone: 970-949-1800 Description: ADDING RECESSED LIGHTING IN THREE BEDROOMS, INSTALLING A DOOR PARTITION IN THE LOFT, UPGRADING BATHROOM VANITIES. Applied.....: Issued... PRJ 11 -0100 04/08/2011 05/02/2011 Occupancy: Type Construction: Valuation: $68,000.00 ......... ........................................ ............................... FEE SUMMARY ................,.»..,,.,.........«......,...> ......,,,.<...............,.... Building Permit ------ - - - - -> $769.75 Bldg Plan Check ----- - - - - -> $500.34 Use Tax Fee------------------ - - - - -> $1,160.00 Electrical Permit ---- - - - - -> $115.00 Elec Plan Check ------ - - - - -> $74.75 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $0.00 Mech Plan Check ---- - - - - -> $0.00 Additional Fees--------------- - - - - -> $0.00 Plumbing Permit --- - - - - -> $0.00 Plmb Plan Check ---- - - - - -> $0.00 Recreation Fee--------------- - - - - -> $0.00 Investigation------------------ - - - - -> $0.00 Will Call ------------------------------ > $10.00 TOTAL PERMIT FEES -- ----------- > $2,629.84 Payments -- ---------------------------- > $2,629.84 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. , -,;;� Signature of wner or Contractor Date %emu£ `�pf2e r Print Name combination permit_012811 CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11 -0060 Owner: GMORE PH S.A. DE C.V. MANOR VAIL LODGE UNIT 470 Address: 595 VAIL VALLEY DR VAIL Location: combination permit_012811 t IRN OF VAIL REQUIRED INSPECTIONS AND STATUSES Permit #: 1311 -0060 Owner: GMORE PH S.A. DE C.V. MANOR VAIL LODGE UNIT 470 Address: 595 VAIL VALLEY DR VAIL Location: Item: 00120 ELEC -Rough Item: 00030 BLDG - Framing Item: 00060 BLDG - Sheetrock Nail Item: 00190 ELEC -Final Item: 00090 BLDG -Final combination permit_012811 TOWN OF VAIL, COLORADO Statement Statement Number: R110000395 Amount: $2,124.84 05/02/201110:52 AM Payment Method: Check Init: SAB Notation: 19790 BECK BUILDING ----------------------------------------------------------------------------- Permit No: Bll -0060 Type: COMBINATION BLDG PERMIT Parcel No: 2101- 081 - 2201 -3 Site Address: 595 VAIL VALLEY DR VAIL Location: MANOR VAIL LODGE UNIT 470 Total Fees: $2,629.84 This Payment: $2,124.84 Total ALL Pmts: $2,629.84 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- BP - - - - -- 00100003111100 ------------------------ - - - - -- BUILDING PERMIT FEES ------ - - - - -- 765.09 EP 00100003111100 ELECTRICAL PERMIT FEES 115.00 PF 00100003112300 PLAN CHECK FEES 74.75 UT 11000003106000 USE TAX 4 9 6 1,160.00 WC 00100003112800 WILL CALL INSPECTION FEE 10.00 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 Tel: 970 - 479 -2128 Web: www.vailgov.com ell Development Review Coordinator r IP Project Street Address: 595 V41 Faller' L 9 rll� * /70 (Number) (Street) / (Suite #) Building /Complex Name: l�/t/YDR lc. Lo1g[ Contractor Information Business Name: Project #: PRSIj' Iya DRB #: -/VA -- Building Permit #: B l l- o n6�) o VAIL� L /ILL4Lj Lot #: R�C- Block #� Subdivision: IT' M F:1 Lj A) Work Class: New ( ) Addition ( ) Alteration ( x) Business Address: P & AX /0,10 City VAIL State: C_ Zip: — /G f 8 Contact Name: _ &"Jroc Contact Phone: 4 7 20. z 17/• / "' Contact E -Mail: ileme ,A 6 <<,(� e�i • �� Contractor Registration Number: /( 7A X Owner /Owner's Representative Signature (Required) Project Information Owner Name: 6Ma2t fl s' A. n - C - 1/ Parcel #: — - (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8840 or visit www.eaglecounty.us/patie) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family X Commercial( ) Other( ) Work Type: Interior (X) Exterior ( ) Both ( ) Valuation of Work Included Plans Included Work Electrical (x)Yes ( )No (XYes ( )No 3o00 Mechanical ( )Yes ( )No ( )Yes ( )No Plumbing ( )Yes ( )No ( )Yes ( )No Building (Y()Yes ( )No (x)Yes ( )No &5,000 Value of all work being performed: $ Gs, O of (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage loo Detailed Scope and Location of Work: &dot, n4 frt cist,6( 1 *SL�_ 3 6. 194k )_S.I� Tr to d w ���� ra �� ✓Q r� �. [S S et she (use additional sheet if necessary) For Office Use Only: Fee Paid: * 5US. D Received From: CD Cash Check # CC: Visa / MC Last 4 CC # exp date: Auth # Date Received: '4 LW RHILDINO PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) TOWN OF VAIL, COLORADOCopy Reprinted on 05 -24 -2011 at 10:08:35 05/24/2011 Statement Statement Number: R110000278 Amount: $505.00 04/08/201101:43 PM Payment Method: Check Init: DR Notation: CK# 19706 BECK BLDG CO ----------------------------------------------------------------------------- Permit No: Bll -0060 Type: COMBINATION BLDG PERMIT Parcel No: 2101 -081- 2201 -3 Site Address: 595 VAIL VALLEY DR VAIL Location: MANOR VAIL LODGE UNIT 470 Total Fees: $2, 629.84 This Payment: $505.00 Total ALL Pmts: $2,629.84 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts BP 00100003111100 BUILDING PERMIT FEES 4.66 PF 00100003112300 PLAN CHECK FEES 500.34 TOWN O BUILDING PERMIT SUBMITTAL REQUIREMENTS Residential condomin remodels /additions (mu IBC buildings) ** *Return this form with vour application * ** X sets of plans required to be submitted Supply DRB application number (i.e. DRB090001) or coov of DRB Action Form A rchitect stamp required on architectural plans. Architect or Engineer's stamp is required on structural, mechanical. olumbinq and electrical plans. Remodel protects not disturbing fire resistive construction within the building may not require stamped plans please contact TOV Building Department staff with anv questions. Building construction type, occupancy, fire sprinkler /alarm information and code analysis for existing buildinq shall be included on the plans. >( Asbestos proiect checklist & testinq results �' Include a key plan showing location of the unit within the building complex. Show location of all existinq or proposed exit doors, corridors or stairways from the unit or building. Floor plans for the unit showing all proposed work. Clearly show new, existing and demolished walls. Indicate wall assembly types (wood or steel studs) Include a door schedule for anv new doors. Include information on fire ratinq as required v" rating assemblv details for floor /ceilinq or roof /ceiling and fire rated walls required. d Fire ratinq details for recessed light fixtures if lightinq is located in a fire rated ceiling. /X For additions, include energy code compliance forms (COMcheck or REScheck) hftp://www.eneLqVcodes.gov Structural plans for any proposed structural work. (stamped and signed by architect or engineer) Mechanical plans required for all proposed mechanical work. Bath fans, dryer duct, kitchen exhaust, HVAC ducts and anv heating or cooling equipment. Show fire dampers as required on ductwork plans. (stamped and siqned by engineer or architect) Plumbing plans for all proposed plumbing work. Include gas piping and sizing plan, drain /waste /vent and water piping. (stamped and signed by engineer or architect) V Electrical plans for all proposed work. Include electrical power and lighting plans, panel schedule and load calculations. (stamped and signed by engineer or architect) NOTES: F:\CDev \BUILDING \ch( y Department of Community Development 75 South Frontage Road Vail, Colorado 81657 Tel: 970 - 479 -2128 Fax: 970 - 479 -2452 Building Permit Application & Submittal Requirements 0 Web: www.vailgov.com Development Review Coordinator t at" Commercial (Including Multi - Family) Follow the detailed guidelines in this packet, prepare plan sets and fill out the necessary forms (provided) for a complete application. Applications must be code compliant and complete to be accepted. uv p TOWN OF VAIL nt-Ian -2()11 PROJECT TYPE Submittal Requirements New Commer- cial Building Multi - Family Interior Remodel (condominium) Commercial Tennant Im- provement (TI) Decks and Balconies Re -Roof Windows DRB Approval d If adding GRFA or Involving any exte- rior work Mo.- If there are any exterior changes V V Plan Review Deposit V V N / I/ N/ Application Form V X/ X / I/ J J Energy Code Compliance Form * ** COM check'" V COM check or REScheck V COMcheck n/a Required if no existing insulation I/ (window U- value) Asbestos Project Checklist & Testing Results I/ mk arier V V Irk n/a n/a Soils Report n/a n/a open hole report @ excavation n/a n/a # of Plan Sets 4 3 3 2 2 2 Survey /Site Plan J n/a J J n/a n/a Civil Plans V n/a n/a n/a n/a n/a Floor Plans V V N/ n/a v Reflected Ceiling Plan ✓ n/a V n/a n/a n/a Roof plan V n/a n/a n/a With changes to roof plan or fram- ing structural plans required n/a Elevations V n/a n/a n/a (or window schedule) Cross section and details N/ n/a If new ceilings or walls are built I/ n/a n/a Mechanical plans J J new J n/a n/a n/a Electrical Plans V V n/a n/a n/a Plumbing Plans X/ n/a n/a n/a Structural Calculations J n/a n/a n/a n a Special Inspection Program V V A V �/ n Foundation Plan V n/a n/a n/a n/ Framing plans V uv p TOWN OF VAIL nt-Ian -2()11 Plan Submittal Requirement Pa r, Format & Scale Drawings must be submitted on minimum 11 "x17" or larger size paper. 24 "x36" is recommended for most projects All sheets in a drawing set must be the same size and sequentially labeled and dated. North arrow and the scale [standard architectural or engineering scales (1/4 " =1', etc)]. Title block with project name, project address and legal description. Pro fessional Seal(s) All drawings and calculations must be prepared by a professional engineer or architect licensed to practice in the state of Colorado must be signed and sealed (original stamp /signature not required) X Survey /Site Plan (see DRB application for detailed list of site plan requirements): • Include the DRB approved site plan, if no site plan was provided with the DRB application the following minimum infor- mation is required on a site plan: • North arrow and scale. • Property information: legal description, square footage and acres of lot, owner's name and mailing address. • Adjacent property information: legal description, owner's name and mailing address. • Property lines, easements, right -of- way(s) • Property and setback lines, and existing and proposed easements. • Existing grades. • Existing layout of building and other structures including decks, patios, fences and walls. • Locations of all utilities • Names of all adjacent roadways. Civil Plans X ❑ Survey (sealed and dated by Colorado licensed Land Surveyor): • North arrow and scale. • Property information: legal description, square footage and acres of lot, owner's name and mailing address. • Adjacent properties information: legal description, owner's name and mailing address. • Property lines, easements, right -of- way(s) (including bearings, distances and curve information). Topography. Basis of bearings. • Adjacent roadways labeled and edge of asphalt for both sides of the roadway shown for a minimum of 250' in either direction from property. • Existing conditions, demolition plan. • Proposed grading: contours, spot elevations, slopes, wall elevations, building floor elevations, matching grades, etc. • Proposed layout of building and other structures including decks, patios, fences and walls. • Utility plan and sign -offs. • Drainage plan and final drainage report. • Erosion control plan. • CDOT Access permit and NTP or at minimum preliminary comments or as required by Town Engineer. � Plans plans shall be drawn to scale and must be dimensioned. (� n"Building Information: 01 • Specify applicable building codes. • Type of construction. APR 0 7 2011 • Number of stories. • occupancy classification. TO WN OF VAI • Mixed occupancy compliance methods (if applicable). • Occupant loads. • Specify if the building will be equipped with a fire suppression system, and the system type. • Building area in square feet (per floor and total), allowable area calculations. • Number of Type A, B dwelling units and accessible hotel /motel units. / / • Plumbing fixture count per 2009 IBC Chapter 29. Differentiate existing from proposed construction. V loor and room uses labeled. Suite numbers listed. Door Schedule locations, sizes, types and safety glazing clearly identified, door hardware, door fire ratings, U values per energy code. ,K Window Schedule: locations, sizes, types and safety glazing clearly identified, U values per energy code. x Existing and proposed plumbing fixtures. Means of egress plan and information: required exits, travel distances and occupant loads tr� Stairs and handrails identified. Provide a detail on the riser height and tread depth for stairs, and height for guards and handrails. ;;/Accessibility compliance: accessible routes, accessible entrances, accessible features and details for all requirements of ANSI 117.1 Reflected Ceiling Plans ❑ Ceiling Heights ❑ Ceiling Finish Materials / Details / Access panel locations Roof Plan X • Roof plans shall be drawn to scale and must be dimensioned. • Roof pitch noted • Roofing material identified (must be Class A, and asphalt shingles must be minimum 300 Ibs per square). • Snow fencing or snow clips shall be identified per TOV ordinance Y Elevations ❑ Elevations shall be drawn to scale and must be dimensioned. ❑ North, East, South and West elevations. Li Show all proposed exterior finish materials, guardrails, windows, doors and finish grades. ❑ Snow fencing or snow clips shall be identified per TOV ordinance Cross Sections and Details X ❑ Sections shall be drawn to scale and must be dimensioned. ❑ Provide building cross sections showing roof, wall and floor assemblies and all building materials. ❑ Detail weather resistive barriers at roof and exterior walls • Insulation R values shown for roofs, walls, floors, slab edge per International Energy Conservation Code • Show roof and crawl space ventilation where applicable • Ceiling heights in rooms and crawl space /basement areas. Y Mechanical Plans • Full size floor plans showing mechanical equipment for each level of the building to scale (for remodel work, show only "new /additional" work) • Complete mechanical room equipment layout. Indicate boiler, furnace, hot water tank • Indicate boiler or furnace size and efficiency (min. 92% efficiency per TOV ordinance) • Complete plans for all proposed HVAC ductwork. Show locations of all smoke /fire dampers • Show all type I and type II hoods where required for commercial kitchens • Complete plans for any kitchen, bath or laundry exhaust ductwork ❑ Show all flue or vents terminations through roof, or side wall ❑ Show fireplace types and fireplace venting ❑ Provide ventilation calculations Elef�rical Plans a Complete lighting and power plans for all proposed electrical work. R/Show all lighting per Comcheck lighting report. For residential, note for 50% of tional Energy Conservation Code (high efficacy) q/ / Minimum lighting requirements must be met. X Complete exterior lighting plan o/ Electrical load calculations per National Electric Code for new construction, or if any new electrical loads are being added. v Panel schedules V Fault current calculations X Plumbing Plans ❑ Full size plumbing plans for each level of the building to scale • Sizes, locations and materials of drain, waste and vent piping. Show drainage slope, vents through roof, sewer connection locations • Show any grease traps or interceptors, or any sand /oil interceptors where applicable • Sizes, locations and materials of water piping. Show locations and types of all backflow prevention devices. ❑ Sizes, location and materials for gas piping. Gas piping plan must show meter location, existing /new gas piping, gas piping total developed length and each branch length, piping material (black iron, or CSST), pipe size and BTU's or CFH for each existing or new appliance served X Structural Calculations ❑ Structural calculations must be submitted for all new commercial buildings X Special Inspection Program ❑ Complete the TOV special inspection forms with all required signatures, and applicable information for your project Foundation Plan ❑ Structural design criteria, specifications listed and design codes listed o Sizes of all footings and foundation walls. Footing /foundation wall elevations noted ❑ Footing /foundation cross sections with reinforcement clearly shown for each area of the foundation (cross section referenced on plan view) E Soils report or assumed soil bearing capacity referenced Framing Plans 6K Provide framing plans for floors, decks and roofs. r'Structural design criteria, specifications listed and design codes listed PC Locations and sizes of all framing components (joists, beams and columns) *K- Identify material types, grades and species. V'Framing details where applicable APR 0 7 2011 TOWN OF VAIL Account: R063671 Location Owner Information Assessment History Parcel Number 2101- 081 -22 -013 Owner Name MV PENTHOUSES Actual (2010) $8,677, Tax Area SC 103 - VAIL (TOWN) - LLC Primary Taxable $709,130 SC103 Owner Address PO DRAWER 2770 Tax Area: SC103 Mill Levy: 44.2270 Situs Address 595 VAIL VALLEY AVON, CO 81620 Type Actual Assessed Acres SQFT DR #470 Improvements $7,647,820 $627,150 3286.000 Legal Summary Subdivision: Land $1,029,870 $81,980 0.075 MANOR VAIL Unit: 470 Transfers Sale Price Sale Date Reception Number 20090112 200827457 200827458 200823608 • Photo • Sketch • GIS Book Page D n APR 0 7 2011 TOWN O�. F VAI Koll Consulting, LLC 311 • oaGo 1079 No Name Lane, Glenwood Springs, CO 81601 970 - 376 -1297 dean @dkollarchitect.com MANOR VAIL RESIDENCE #470 REMODEL MANOR VAIL LODGE, VAIL COLORADO SCOPE OF WORK SUMMARY 3/28/11 The enclosed Scope of Work Summary, List of Changes /Additio ecif and Drawings constitute the Construction Documents for a Remodel of an exist 'ouse at IVlano1 Lodge, Vail, Colorado. ?^ Reference is made to the original Construction Documents for this Project titled Manor Vail Condominiums, Vail, Colorado dated 5/16/07 — Full Permit Response as issued by Zehren and Associates, Inc. These original Construction Documents are hereby specifically incorporated into the Manor Vail Residence #470 Remodel project to serve the purpose of reference, guidance, and to otherwise facilitate coordination and deployment of construction methods, means, and materials on the part of the General Contractor and Subcontractors. The Contractor shall familiarize himself and all appropriate Subcontractors /Suppliers with the contents of these original plans and specifications, as well as existing as -built conditions at the project site, in accordance of the goal of matching, to the greatest extent possible, all newly remodeled areas to existing construction materials, finishes, and craftsmanship — unless otherwise addressed in these remodel drawings and specifications. The attached remodel specifications and drawings address the scope of work to be included in the Manor Vail Residence #470 Remodel. In some cases, portions of the original drawings are `redlined' to more easily highlight the revisions /additions or provide the Contractor with key reference information pertinent to the original design or existing conditions. In addition, new suppementalspecifications . drawings and/or s are also provided to delineate the new changes and I 6 o t `i ; R t60itfcorporated into the existing residence. GOMPLIA C C �MFL'6�1 [EuvLLID APR 0 6 2011 TOWN OF VAIL Koll Consulting, LLC 1079 No Name Lane, Glenwood Springs, CO 81601 970 -376 -1297 dean @dkollarchitect.com MANOR VAIL RESIDENCE #470 REMODEL MANOR VAIL LODGE, VAIL COLORADO LIST OF CHANGES /ADDITIONS 3/28/11 1. Add 2 recessed can lights with switches at each of Bedroom's 2, 3, and 4. Re: Sheet 5 and 6. 2. Add a wood beam to ceiling above and to the inside of the Loft rail to support 6 new sliding wood doors. One new fire sprinkler head may be required by this change — To Be Determined. Re: Sheet 7 and 8. 3. Add wall and door at Loft Entry with new light switches and outlet. One new fire sprinkler head may be required by this change — To Be Determined. Re: Sheet 7. 4. Remove existing Master Bath vanity /cabinets /countertop /sinks and add new Master Bath vanity /cabinets /countertop /sinks. Re: Sheet 4 and 9. 5. Add new drawers at vanity cabinets at Bath 2, 3, 4, and Loft. Re: Sheet 5, 6, and 7. 6. Add new cabinet above the toilet at Bath 2, 4, and Loft. Re: Sheet 5, 6, and 7. 7. Replace existing 1 hour rated attic access panel with a new one -hour rated 2'- 6" x 4'- 4" wood door with wood trim. See Sheet 7. 8. Add light with motion activated switch at Entry Closet. Spec to be provided. See Sheet 3. 9. Change all closet lights to be activated by motion sensor switch. Spec to be provided. These changes were to be part of the original scope but the schedule did not allow for the completion of these items within the schedule constraints of the Manor Vail Lodge Condominium Associations Rules and Regulations related to Remodels. Hence, these changes are to be tied to and covered under the Agreement between the Owner /Contractor/Manor Vail Lodge Agreement relate to Construction Activity within the Manor Vail Lodge. LOAD CALCULATION PER N.E.C. EXAMPLE D1 (a) MANOR VAIL - UNIT 470 GENERAL LOAD - 3,779 SQ. FT. @ 3W /FT SMALL APPLIANCE LAUNDRY/APPLIANCES TOTAL 3000VA @ 100% 16,500VA - 3,000VA = 13,500VA @ 35% NET LOAD DISHWASHER CLOTHES DRYER DISPOSAL AND TRASH COMPACTOR WHIRLPOOL TUB RANGE /COOKTOP RANGE HOOD A -V EQUIPMENT MECHANICAL / FAN COILS / PUMPS NET CALCULATED LOAD MINIMUM FEEDER AMPS SERVICE BUSSING / MAIN AMPACITY 157.18 200.00 EXISTING FEEDER IS # 4/0 ALUMINUM SUPPLIED BY 2 -POLE / 200 -AMP / 1 -PHASE BREAKER Tow Of Vail o R APR 0, 2011 LOAD IN VOLT -AMPS 11, 337.00 3,000.00 1 15, 837.00 3,000.00 4,492.95 7,492.95 1,300.00 5,000.00 1,500.00 1,600.00 9,600.00 1,200.00 1,500.00 3,500 00 32,692.95 3u -oo(�o Dec 03 10 05:24p Debra Geddes 9709265049 �i p.2 Lod B ( t M-00ao Z N m Co O N (O N N C N (D CO N N CSI O N M V CD Co M m O N — J � m J % ¢ ° t � d V- a W Co l O O ct C7 W F w W CO Z () W 0 N Z U 111 ^ N p J D N D z_ q y > U LLJ LL 03 03 U 0: `I 1 ¢ w w w C_ ¢ c Z °' a d a o c) O W a N a= W U LL = NO Z O ° m M N p v � LL ' W x o o w z m ,p m LL� LL LL m a m v 1= W U L. C:) } a ¢ 4' ¢ Q Q Q < < W Q W W a c+� W ~ LU O LU O O c 0 0 0 N N N CV � 0 N 0 0 N LO 0 o a o 0 0 0 0 0 +'� N M - tl� O m m a 0 i N N i -- + t + + + m ¢ + ' + + i + + } 1- + + + + I + L w N N N N O N N N O N N N N N N N N C's N N Q Y W W � Q N CL Z � 0 d w a W ►- � 0 a w O U, m a W U a m ¢ F ~ (1) W W'o _ U ° W Z= U F. F !- J V Q O W W W I.- v� Q CO O oa m m O m U U W= Cm O' W a O O of N M V Q' M uj� (D U 0 Q¢ V � Z � LL U O O 11J [L' ►- z = # F- F- = W F- F- � F- W LaLI F- m J O -' L J O ❑ (1) F - F - w Q¢¢ to to _r h v� z (7 z z U 0 LL U � O m 2 m ¢¢¢= z¢ J (7 J ¢ 0 W J Q' W° J O w J W O W a z °° g >- O F- < o V.3 _ m U W F^ =) J Z O & ¢ E Q Ci iC M to I� 67 M N O7 N C7 N I� N N N r M M In I� M M M Ch B ( t M-00ao Dec 03 10 05:24p Debra Geddes 9709265049 p.3 br- < v 0 — z U oN U3 0o F o_j 3 \ QN^ Q VQ = O C x 3 n tn La Ld QO0p� VI W N N O� J�IgI> n Q� >Q m 0 0 0ow 3 NN n. aQ�kQ N Lo O J � W ZEI Z� O� 3 n tn N N O J � W ZEI Q a. � J -• W t' to o J �o o om M Q v ° o W W N LL \zyN QUSN F- �ZXN z ({ �U O() Lii-3 V �uJ O O Z in �rO�l V1 � C) ES U Jm Q tco E z � zi,- � oo 9M£ OOZ 9M£ OO Z OOZ W N N N tCO:) QO C ©CONCO m OC 9M£ `° 9M£ DOZ N N 4' W N F t N- N~ <(g) = ©CO OO CO OOCO O # `Irk O1 v Q O� VI W rW �W �LJ n �O(� r1 SEW U O 0 m Z Z Z N Z N z ACC �4Co AC C �OCo HOC AN E Co JU W LL. W W �W pate: ?� ? ®CNZ)�CN =® N?® Co C DC --� �Q W S W W W .- W .- W �O`^e' �- Z�CN Z© N Z� N =) N Z O 0 CO= D CO =OC W Z U W W W �- W W �� 1 J `��/ a. a. ?n3 F- N - �n//�2�11J N - N - �s ©C°pOVCo =OCp�LCO�t7C 16AIC 6" Line Voltage Airtight IC Rated New Construction Product Specifications Description: The 16AIC recessed down light can be used for either commercial or residential new construction applications. For use insulated ceilings. Designed for direct contact with insulation. Airtight certifed ASTM E283 Lamping: 75W PAR30 / R30 max. 75W PAR38 / R40 max. 75W A -19 max. " see trim for lamp type Socket: E26 Medium base socket Socket Plate: Adjustable socket plate adjusts and locks in position without tools for multiple lamp and trim types. NB Loose Socket Option: Free floating socket clips directly to trim for precise lamp placement, optimal performace and uniformity from fixture to fixture. (Specify -NB for loose socket option) Junction Box: Galvanized steel junction box with 1/2 "and romex wiring knockouts, with removable access plates for easy installation. Installation: Includes adjustable hanger bars (14 " -25 ") with integral nail. Bar hangers can be repositioned 90 without tools. Barhangers can be locked into place with locking screws. Thermal Protector: Integral thermal protector protects against improper lamping and insulation proximity. Labels: NRTL listed for damp locations NRTL listed for through branch wiring NRTL listed to US and Canadian safety standards - NRTL listed for direct contact with insulation - Airtight certified ASTM E283 Catalog #: Type: -t lo/4 rZ 1- Notes: 1L,�s :tow Dimensions L Ceiling Cutout 7 A' L�o CE 11" i Ordering Matrix 16AIC Series I Options blank fixed socket -NB loose socket L O Cam► LL llll O Q AL `Note: Specifications and dimensions subject to change without notice. 2861. E La Palma Ave. • Anaheim, CA 92806 • Phone: 1.800.961.5321 • Fax: 1.800.961.5322 • www.intenselighting.com ; I Where CreaRMlysaOPrAarmaes Mser Catalog #: Type: 6" Line Voltage Shallow Trims Notes: - 7 5 v i PPO— - i"lzI AA_ TAD Fixed Socket Trims CATALOG # DESCRIPTION LAMP FINI TRIM O D . ICM30 6" PAR30 Metal Baffle PAR30 / R30 75W max. W, W -SF, B, SN, MO 7 A' ICM40 6" PAR38 Metal Baffle PAR38 / R40 15OW max. W, g, SN, MO 7 A" (75W max IC Rated) ICP30 Phenolic Baffle With Phenolic PAR30 / R30 75W max. W 7 A' " White Ri ng W Ring ICP40 6" PAR38 Phenolic Baffle With Phenolic PAR38 / R40 150W max. W 7 A" White Ring 6" Baffle W/ Regressed Lens O IC62 Specify Lens Type: -AB: a/balite, -SB: sand A19 60W max yy g 7 Ya" blasted, -PR: prismatic, -FR: fresnel, -CR. clear (40W All 9 max IC Rated) tempered, -FSP: frosted spot ® IC65 6 "Clear Reflector W/ Baffle Al 100W max W g 7 Ya" (60W All 9 max IC Rated) j ICR9 6" Reflector For Al 9 Lamp Al 9100W max W, g, C, SD 7 A" (60W Al max IC Rated) ICR3 For / 6" Reflector PAR30 Lamp PAR30 / R30 75W max. W, B, C, SD 7 Ya" / ICR4 6" Reflector For PAR38 Lamp PAR38 / R40 15OW max. W B C, SD 7 A " (75W max IC Rated) ICRW9CW 6 "Wall Wash Reflector PAR30 / R30 75W max. CW 7 A" O ICRW5 6 "Wall Wash With Baffle PAR30 / R30 75W max. W, B 7 W ICR12 6 "Clear Reflector W/ Drop Glass Trim All 9 60W max. C, SD 7 Ya" Loose Socket Trims For Use W/ NB Housing ICA30 6" PAR30 Adjustable Gimbal PAR30 / R30 75W max. W 716" ICA38 6" PAR38 Adjustable Gimbal PAR38 / R40 15OW max. (75 max IC Rated) W 7 A* ICA31 6" PAR30 Adjustable Gimbal With Baffle PAR30 / R30 75W max. W 7 YV ICA42 6" PAR38 Adjustable Gimbal With Baffle. PAR38 / R40 150W max. (75 IC Rat max i [E 0 n t7 v D APR 07 2011 K ey Code i/AIL •: Wet Location Listed *:Optional metal trim ring. Specify MW (metal white), 8 (metal black), C (dear), MO (mocha), SN (satin nickel) WN OF Special Finish: W (white), 8 (black), SN (satin nickel), order trim ring Specify G (gold), AN (antique nickel), AC (antique copper), CAP (cappuccino) MO (mocha), PW (phenolic white). Reflector Finish: C (clear), W (white), B (black), G (gold), SD (semi diffuse) -Note: Specifications and dimensions subject to change without nonce. 2861. E La Palma Ave. - Anaheim, CA 92806 - Phone: 1.800.961.5321 - Fax: 1.800.961.5322 - www.intenselighting.com �� LlcxTtx� 'OB x7rois I I - oo6o CreafMb'sed Par/artnax� ilfset 6" Line Voltage Shallow Trims Loose Socket Trims For Use W/ NB Housing APR 07 2011 TOWN OF VAIL Catalog #: Type: Notes: Key Code. •: Wet Location Listed *: Optional metal trim ring. Specify MW (metal white), B (metal black), C (clear), MO (mocha), SN (satin nickel) Special order trim ring Specify G (gold), AN (antique nickel), AC (antique copper), CAP (cappuccino) Finish: W (white), B (black), SN (satin nickel), MO (mocha), PW (phenolic white). Reflector Finish: C (clear), W (white), B (black), G (gold), SD (semi diffuse) ' �'e��d /� /� `Note: Specifications and dimensions subiect to chance without notice. . (/ �<�L� 2861. E La Palma Ave. " Anaheim, CA 92806 • Phone: 1.800.961.5321 • Fax: 1.800.961.5322 • www.intenselighting.com fit -ono CATALOG # DESCRIPTION LAM FINI TRI O D 7Ya" IC88 6 "PAR30 Eyeball PAR30 / R30 75W max. W, B, SN, MO 7Ya" W 7 /" Fixed Socket Wet Location Trims ICB9 6" PAR30 Regressed Eyeball PAR30 / R30 75W max. W, B, SN, MO 7 Ya" ICR30 6" Full Reflector Baffle Trim A 19 60W max. W 7Ya" APR 07 2011 TOWN OF VAIL Catalog #: Type: Notes: Key Code. •: Wet Location Listed *: Optional metal trim ring. Specify MW (metal white), B (metal black), C (clear), MO (mocha), SN (satin nickel) Special order trim ring Specify G (gold), AN (antique nickel), AC (antique copper), CAP (cappuccino) Finish: W (white), B (black), SN (satin nickel), MO (mocha), PW (phenolic white). Reflector Finish: C (clear), W (white), B (black), G (gold), SD (semi diffuse) ' �'e��d /� /� `Note: Specifications and dimensions subiect to chance without notice. . (/ �<�L� 2861. E La Palma Ave. " Anaheim, CA 92806 • Phone: 1.800.961.5321 • Fax: 1.800.961.5322 • www.intenselighting.com fit -ono ICR35 6 "Full Reflector Trim A1960Wmax. W 7Ya" ® ICRS30 6 "Shallow Full Reflector Baffle Trim A19 60W max. W 7 /" Fixed Socket Wet Location Trims ICS6 6 "Shower With Drop Opal Lens A19 4 0W max, A19 40W max. (ICRated) W, PW 7 X" • OO ICS7 6" Shower With Sand Blasted Frosted Spot Lens A19 60W max, A1940W max. (ICRated) yy pyy SN, MO 7Ya" ICS3 6" Shower With Fresnel Lens A19 60W max, W, PW, SN, MO 7 A" A1940W max. (ICRated) • ICSS 6 "Shower With Sand Blasted Lens A19 60W max, yy pN/ SN, MO 7' /a" \ A19 40W max. (ICRated) O IC52 6 "Shower With Albalite Lens A19 4 0W max, A19 40W max. (ICRated) W, PW, SN, MO 7 A" APR 07 2011 TOWN OF VAIL Catalog #: Type: Notes: Key Code. •: Wet Location Listed *: Optional metal trim ring. Specify MW (metal white), B (metal black), C (clear), MO (mocha), SN (satin nickel) Special order trim ring Specify G (gold), AN (antique nickel), AC (antique copper), CAP (cappuccino) Finish: W (white), B (black), SN (satin nickel), MO (mocha), PW (phenolic white). Reflector Finish: C (clear), W (white), B (black), G (gold), SD (semi diffuse) ' �'e��d /� /� `Note: Specifications and dimensions subiect to chance without notice. . (/ �<�L� 2861. E La Palma Ave. " Anaheim, CA 92806 • Phone: 1.800.961.5321 • Fax: 1.800.961.5322 • www.intenselighting.com fit -ono 17871 - Technical Specifications - GE Home Lighting Products WORtOW109 PARTNER GE Lighting Pagel of Products for Your Home SITE SEARC�y HOME PRODUCTS DESIGN WITH LIGHT COUPONS/ SPECIAL OFFERS HQ111e > RlDdACt > Track _99015ed > Indoor EIQQ&ht > 17871 17371 — SOPAR30/H/FL25 GE Edison TIA PAR30 Where to Bu 1 FAQs I Contact U (E r s Specifications Prins W14CRE TO UY PRODUCT INFORMATION Klew Lar ar Base Medium NP Product Code 17871 Description 50PAR30/H/FL25 UPC 043168970143 GENERAL CHARACTERISTICS -----Halogen - PAR Bulb PAR30 B ase Medium NP Wlament CC-8 Rated Life 3000 hrs Primary Application Indoor Floodlight PHOTOMETRIC CHARACTERISTICS Initial Lumens 630 Center Beam Candlepower (CBCP) 2300 Color Temperature 2800 Nominal Initial Lumens per Watt 12 ELECTRICAL CHARACTERISTICS Voltage DIMENSIONS 120 Maximum Overall Length (MOL) 3.6200 Bulb D i ameter (DIA) 33/4 A CAUTIONS & WARNINGS See list QLoutLms_&Aajn1flgS l o > N r- O LL 0 Qef o- z nnV Home I Products I Design with Light I Coupons / Special Offers I Where to Buy I FACIS I Contact Us Sign up for our e•Newsletter GE Around the World I Site Map I Commercial Products & Solutions I Press Room I Corporate jEnter E-Mail Add, ss,' 'FGO L ------ j g t t r .D0( 0 0 lift p://genet.gelighting.co)nZizt oditcts/Dispatcher?RE-QUEST 3/31/2011 08 -01 -2011 Inspection Request Reporting Page 7 4:41 Dm Vail, CO City Of Requested Inspect Date: Tuesday, August 02 2011 Site Address: 595 VAIL VALLEY Dig VAIL MANOR VAIL LODGE UNIT 470 A/P /D Information Activity: 611 -0060 Type: COMBO Sub Type: AMF Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: GMORE PH S.A. DE C.V. Contractor: BECK BUILDING COMPANY Phone: 970 - 949 -1800 Description: ADDING RECESSED LIGHTING IN THREE BEDROOMS, INSTALLING A DOOR PARTITION IN THE LOFT, UPGRADING BATHROOM VANITIES. Reauested InsDection(s Item: Requestor: Comments: Assigned To: Action: Item: Requestor: Comments: Assigned To: Action: 90 BLDG -Final BECK BUILDING COMPANY 471 -16 J GON Time Exp: 190 ELEC -Final BECK BUILDING COMPANY 471 -16 J GON Time Exp: Requested Time: 08:30 AM Phone: 970 -949 -1800 -or- 970 -949- 4335 Entered By: JMONDRAGON K V Inspection History Item: 120 ELEC -Rough ** Approved ** 05/26/11 Inspector: sgremmer Comment: 06/21/11 Inspector: sgremmer Comment: Item: 30 BLDG - Framing ** Approved ** 06/29/11 Inspector: JRM Comment: Item: 60 BLDG - Sheetrock Nail ** Approved ** 06/29/11 Inspector: JRM Comment: WALLS ONLY 07/14/11 Inspector: sgremmer Comment: Item: 190 ELEC -Final Item: 90 BLDG -Final Requested Time: 08:00 AM Phone: 970 -949 -1800 -or- 970 -949- 4335 Entered By: JMONDRAGON K Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED Action: PI PARTIAL INSPECTION Action: AP APPROVED REPT131 Run Id: 13372