HomeMy WebLinkAboutA06-0023.pdf a��ucat�o� wiLa� r�ar �� acc��r�� E� in�cc����.�r� ora u�s � c,`� G �°
Praject #:
�uiiding S�ermi4 #.
Alarm Permit #:
� __ 970-999-29�5 (ln�ecti r�s) �
��''IdOF �'R1�, °T�WN _OF'_ VAI�. �iF2E_AimQa17M�E�MiTAPPLiGAI°IOid.
Commerciai � Residential Fire A►acro strop drawings are required at time o� 75 5.
Fronfiage Rd. applicaYion submittai and must incEude ieefarmation Iist�d on the i/aif, Colorado
87657 2n° page of tl5is farm. Application wili not be accepted withau4 this
infoemateon.
TRACT
Fi Alarm Contracror: Town of Vail Reg. No.: Contact and Phone #'s:
�O s '1- � SrY> <'� - `,. 1�
E-Mail Address:
Contractor Signature:
Cl3t�PLE'TE VALUAT{ON6 PCBR .�LAR6d I�EftAPo4T ([.abor & F�ateria(s)
Fire Alarm: $ �� � .�� �
Contact Ea le CounE Assessors O�ce aY 970-328-8640 pr visif www.ea fe-counf .com for Parcel #
Parcel # '�, "� t'� <(
Job Name: � ` �(� , � �1 a� � Job Address: l .-��[� � �j 1r
T �— T � U S l
Legal pescription Lot: ' � Block: Filing: Subdivision: `
Owners Name: $� Address: �� � Phone:
Cnginee`s�x � 5�� Address: .� � —. S �� Phone:
Dotailed Location ofwork: (i.e., floor, unit #, bidg. #)
U �
Detailed description onf`work:
{ I-Y1Q ti �J Y ' r
Work Class: New ( Addition ( ) Remodel ( ) Repair ( ) Re[ro-fit ( } Other ( )
Type of Bidg.: Single-famiiy ) Two-family ( ) Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( )
No. of Existing Dwelling Units in this buildin ' No. of Accommoda[ion units in this building:
Does a Fire Alarm Gxist: Yes ( ) No ) Does a Fire Sprinkler Systern Exist: Ye ) No ( )
�ik:c�YV: ��k��k*�kk�k�Akkfi*xRX�tk%iFSkk:F&*k4��� ��FIC` USE OP�LYR��kR***RirR:F.iA*kAk�kRkX"ki'AAA0.�AYAkY A ��FAF
� Qth�r �'ees �i�a€e F�ece9ved
PUbifa Wa,y Permit �ee Aceepfedl�y � ((`, (�-' � i � �l
�� O � � ������GR�u�� � � � , _ � � � �
e . �� � t �, �`` �°. 'y'�";"``" � � '�` F�' �,',:'�k ,� �
, , , ��x ,�3� „ r ; FEB 13 20�6 ' �J
\\Vaiiltlata\ctlev\FORMSIPERMITSWLRMPE . O E �2� � � �-�� �� � W/2M2002
> .-�t _ ����t�z��` �..�O��,c�r��%�, -rowN oF � ,«, � t-
_ _.
� ;<;, � lJ�C /�1�l'�'. < � r�k' _ .
�,,; C>�-..- < � I.- C`�'.(n . _ _
O
&
�
SEQUENCE OF OPERATIONS : LEGEND : �
Q Q SYMBOL DE�9CE MANUFACTURER/PART# MOUNTING
z
� a �'
N Q � N Ademco Vista-50P
J � O �n O � O Fire Alarm Panel w/ 7AH Batteries Mount on wall in monufocturer hack6ox
p Z � N Fa- � � O H
Q 0 0 � N m 1n � tn wo Alphanumeric Keypad Ademca 6139 Mount on wall �
w
a = _ � z � z a z � '�' S
U Z � a CG �' � y K � O
� � o F O N O O o � Smoke Detector Ademco 5192SD 4" squore box o
= Z ~ Z ~ Z W t~A z
DEVICE ¢ ¢ � N o N o N � ¢ � Chemetronics 601
DESCRIPTION F r � � Q qa O �a o � O Heat Detector w 47935N Addressable module �
� 4° squore box w
¢ ¢ H ti F h h � 1- ¢ _ ¢` .o
u
SYSTEM SMOKE OR HEAT DEfECTORS X X �' Sounder System Sensor PA400W Single gong box � �o �
+— � `v
'o d a
Weatherproof Horn/Strobe System Sensor P1224MCK WBB Backbox � � ° m
m m m
AC POWER LOSS X X µ� � � w
� o
o m �
GROUND Fnu�T X X GENERAL NOTES: (� ° o a
Of M l�
oPEN ClRCUiT X X 1 . ALL EQUIPMENT IS TO BE INSTALLED AND TESTED IN ACCORDANCE WITH MANUFACTURER �
STANDARDS, FIRE DEPARTMENT REQUIREMENTS AND NFPA 72 .
SPRiNK�eR wnrERF�ow swiTCH X X X X 2 • REFER TO MANUFACTURERS DATA SHEETS AND INSTALLATION INSTRUCTIONS FOR FURTHER �
INFORMATION REGARDWG PRODUCT INSTALLATION , WIRING DIAGRAMS , PROGRAMMING AND
DEVICE OPERATION .
i
SPRINK�ER VALVE TAMPER SWITCH X X /��
VJ �
PROJFCT INFORMATION : � ° _
yt' m N
Va
LOT 12 RESIDENCE � � � �
� Lot12 1 78 � ALPINE DRIVE � ° � w
m � a
AdemcoVista50FACP VAIL , COLORADO a " "
Standby
Numberof Current TotalCurtent FIRE ALARM S I/ s �' EM
Device Type Devices (Amps) (Amps)
Main FACP CPU 1 X 0.032 = 0.032
4193SN Senal Interface 4 X 0.00015 = 0.0006 AHJ : VAIL FIRE DEPARTMENT
5192SD Smoke Detectors 9 X 0.00084 = 0.00756 APPLICA9LE CODES: 2002 NFPA 72 , 2003 IFC, 2003 IBC
6139 Keypad 1 X 0.04 = 0.04 OCCUPANCY: GROUP R
SUM COLUMN FOR STANDBY LOAD 0.08076 = AMPS USE: Dt�EX S i r'-.
Alarm Load u,i
Numberof Current ToWlCurrent FIRE ALARM SYSTEM FOR SINGLE FAMILY HOME. A NEW VISTA 50 PANEL WILL BE WSTALLED . V a
Device Type Devices (Amps) (Amps) SMOKE DETECTORS WILL BE INSTA�LED IN SLEEPING ROOMS, STAIRWELL LANDINGS AND AREAS O � �
Main FACP CPU 1 X 0.032 = 0.032 OUTSIDE OF SLEEPING ROOMS . HEAT DETECTORS WILL 8E INSTALLED IN THE GARAGE, � U Z
4193SN Serial Interface 4 X 0.00015 = 0.0006 �UNDRY ROOM AND KITCHEN . SOUNDERS WILL BE PROVIDED IN SLEEPING ROOMS AND AS � � Q
5192SD Smoke Detectors 9 X 0.0196 = 0. 1764 NEEDED TO ACHIEVE AUDIBILIIY. THE SPRINKLER SYSTEM WILL BE MONITORED BY THE FIRE w O Q �
6139 Keypad 1 X 0. 1 = 0. 1 ALARM PANEL. AN OUTSIDE HORN/STROBE WILL BE WSTALLED TO ACTIVATE ON WATERFLOW U O � �
PA400 Sounder 5 X 0.015 = 0.075 ONLY. A KEYPAD WILL BE PL4CED AT THE ENTRANCE FOR FIRE DEPARTMENT USE. W � p� �
SUM COLUMN FOR STANDBY LOAD 0.384 = AMPS � ¢ W
Standby Load Required Standby Time in Hours w > � O
CuRent (Amps) FIRE PROTECTION ENGINEER : � w O w
SHANER LIFE SAFEIY { > a p
0.08016 X 24 = 1 .92 ✓
PO BOX 1073 �,� �� � � o �
Alarrn Load Required Alarm Time in Hours FRISCO , CO 80443 �� � W O m
Current (Amps) (15 MINUTES) FiRE ����t��� J Z F. p
0.384 X 0.25 = 0. 10 PHONE: 970- 409 - 9082 ��_� � _ �,� � a v w
Add Standby and Alartn Load for Required FAX : 720 - 294 - 9849 � Q � �
Ampere Hour Battery 2•�2 � � � O w
Multiply by the Derating Factor of 1 .2 a � U p
Total Ampere Hours Required = 2.42 o�,� av oa.E
BatteriesProvided: 7AHMinimum DLS 1123106
- .'�.. ,�.`��C�.Y' SMEEiOESCRIPTION�
- �' COVER SHEET
�1���� CALCULATIONS
shEE, e
FA-00
�
�
�
0
>
�
<
0
1 PAIR DATA � O
1 PAIR SOUNDER � �`
� ADE �� CO ' ° e
EOLR �5 typ) (4 typ) (9 (yp) VISTA 'rJOP � ` a �
O /� c �
a �
�� c p1 m
n, o y v
W � � q
� N {p V
(� �YP) O l� o �o N
DIALER - ---. � .�� '�- - T'S o � N
DEDICATED 120V J II � c � '`^•! p �
TELE LINES=� Q v J\ m M 4
O _..� e. � V � � W
SYSTEM ONE - LINE DIAGRAM - � �
NOTE 1 . NO T—TAPPING PERMITTE� ON ANY CIRCUIT �
NOTE 2. ALL WIRING TO BE 18AW� FPL. L^-`-
W
UPPERLEVEL � � �
mQ
Lot 12 MAIN LEVEL ��8�� = ,�-0�� � ° �
� oo
ZONE LIST va" = r-o" (� ° � �
s�W'' m � z
C
DEVICE # DEVICE TYPE LEVEL DESCRIPTION �•"��� � � iNSrn�� KNOx eox iN � " a
001 HEAT DETECTOR MECH MECH RM AT FACP
��`S(���'� FREATDEPARTMEOTED BY VAIL a � �
002 SMOKE DETECTOR LOWER GUEST MASTER BEDROOM ��A� ��e�
003 HEAT DETECTOR LOWER LAUNDRY ROOM y ' /��
. - ,. . ❑— _ _ �. _ - - II — _ — � - - _�
004 SMOKE DETECTOR LOWER ELEVATOR EQUIP RM - , .
005 SMOKE DETECTOR LOWER STAIRWELL LANDING FiRE A�a,RM svs7EM I I
SHALL MONITOR �e„ ,�,�, I I
006 SMOKE DETECTOR LOWER MUD ROOM AT ELEVATOR � - saRwK�ER wnTERF�ow p� � � I I
007 HEAT DETECTOR LOWER GARAGE nNO inrnPER. usE zoNEs
008 HEATDETECTOR MAIN KITCHEN , ota nNO o� s. �a=���
009 SMOKE DETECTOR MAIN WASTER BEDROOM � W
010 SMOKE DETECTOR MAIN OUTSIDE MASTER BDRM _ U a
�
011 SMOKE DETECTOR UPPER STAIRWELL LANDING � � V W
012 SMOKE DETECTOR UPPER VJEST BEDROOM � � J Q
013 SMOKE DETECTOR UPPER EASTBEDROOM �f� O W �
014 MONITOR POINT SPRINKLER WATERFLOW I y U Q � J
015 MONITOR POINT SPRINKLER TAMPER I Z V p
016 SPARE y,� \ � a W
017 SPARE � w > Z p
018 SPARE r` - �' LLI m
019 SPARE O �' N > a p
020 SPARE k - �- O � j=
021 SPARE � � : � w O m
022 SPARE U � � Z
023 SPARE
024 SPARE � � .-:_c. r <� '� - � ao Z �
�
025 SPARE , at _c 4 gw , 'G.�v' . ;. �P�G9 '•. t� d .�— �U 0
THRU = _,.',
050 $PARE , y� �� ,� V5,,3 Z G�' or+nwrvar onre
MECH LEVEL ,,I p_ ,p LOWER LEVEL , . , � _ � ��s 1/23106
C�11'�AT �T �I:�iJC� 1/8�� _ ��_��� 1 ?'� '.. . aHEFr cescaivt'ioN
1/8" = 1 '-0" ^ ' •.. ' Ci •"
��,�e I���Crn� �' • -= t- FLOORPLANS
D� - a\ - O�c
�O1'�A�— ' RISER20NE LIST
sHEErc
� ��'��'� FA-01