HomeMy WebLinkAboutA11-0016TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Permit #: A11 -0016 Job Address: 2672 CORTINA LN VAIL $0.00 Total Calculated Fees - -> Status ...: ISSUED Location.....: $0.00 Additional Fees ---------- > Applied..: 04/22/2011 Parcel No...: 210314203034 $0.00 Total Permit Fee--- - - - - -> Issued . .: 04/28/2011 Project No $0.00 Payments ------------------ > Expires. .: 10/25/2011 OWNER POCKROSS,KEITH M & MIRIAM R 04/22/2011 $0.00 106 UNIVERSITY BOULEVARD 3 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Approvals: DENVER Item: 05600 FIRE DEPARTMENT CO 80209 -3234 04/27/2011 mvaughan APPLICANT THUL ELECTRONIC SYSTEMS 04/22/2011 Phone: 970 - 949 -4638 P O BOX 534 AVON CO 81620 License: 112 -S CONTRACTOR THUL ELECTRONIC SYSTEMS 04/22/2011 Phone: 970 - 949 -4638 P O BOX 534 AVON CO 81620 License: 112 -S Desciption: FIRE ALARM UPGRADE FOR REMODELED SINGLE FAMILY HOME. Valuation: $4,500.00 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Electrical --------- > $0.00 Total Calculated Fees - -> $456.75 DRB Fee --------- > $0.00 Additional Fees ---------- > $0.00 Investigation ---- > $0.00 Total Permit Fee--- - - - - -> $456.75 Will Call --------- > $0.00 Payments ------------------ > $456.75 TOTAL FEES --> $456.75 BALANCE DUE--- - - - - -> $0.00 ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Approvals: Item: 05600 FIRE DEPARTMENT 04/27/2011 mvaughan Action: AP CONDITIONS OF APPROVAL ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADV ANCE BY�TF PHONPAT 970 :4,�Aj?252 FROM 8:00 AM - 5 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL, COLORADO Statement Statement Number: R110000373 Amount: $456.75 04/28/201103:01 PM Payment Method: Check Init: LC Notation: 417497 / THUL ELECTRONICS ----------------------------------------------------------------------------- Permit No: All -0016 Type: ALARM PERMIT Parcel No: 2103 -142- 0303 -4 Site Address: 2672 CORTINA LN VAIL Location: Total Fees: $456.75 This Payment: $456.75 Total ALL Pmts: $456.75 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 FIRE ALARM PERMIT FEES 168.75 PF 00100003112300 PLAN CHECK FEES 288.00 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 Tel: 970 - 479 -2128 Fax: 970 - 479 - 2452 Web: www.vailgov.c D D evelo pmen a e dn ' FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Project Street Address: 2672 CORTINA WAY (Number) (Street) Building /Complex Name: Contractor Information: Company: Thul Electronics Company Address: PO Box 534 City: Avon State: CO Contact Name: Ron Davidson Contact Phone: (970) 949 -4638 E -Mail ron @thulelectronics.com (Suite #) Office Use: Project #: PiRs 1 I — 00(0 Building Permit #: 6 11 – Alarm Permit #: A I l – C) C) 1 U Lot #: Block # Subdivision: Detailed Description of Work: FIRE ALARM UPGRADE Zip: 81620 FOR REMODELED SINGLE FAMILY HOME. SEE PLANS FOR DETAILED SCOPE OF WORK. (use additional sheet if necessary) Town of Vail Contractor Registration No.: 112 -S Does a Fire Alarm Exist? Yes ( +) No( ) Dlgi[allys,gnedbyDeborahShane[ Does a Sprinkler System Exist? Yes ( +) No( ) Deborah Shaner oNcn= DeborahS ,1, o =6han. Safety, X u =FPE ,email =shaneds @comcascnet. ­US Date: 2011.04.20 13 41:16 - 06'00' Work Class: Contractor Signature (required) New ( ) Addition ( )Remodel ( +) Repair ( ) Property Information Retro -Fit ( ) Other ( ) Parcel #: 2103- 142 -03 -034 (For parcel #, contact Eagle County Assessors Office at 970- 328 -8640 or Type of Building: visit www.eaglecounty.us /patie) Single - Family (+) Duplex ( ) Multi - Family ( ) Tenant Name: Commercial ( ) Restaurant ( ) Other ( ) Owner Name: POCKROSS, KEITH M. & MIRIAM R Date Received: Complete Valuation for Fire Alarm Permit: Fire Alarm $: $4500 ffTl -' ME-5 WK 4u lull OWN OF-VA-1 29- May -09 P R O D U C T I N F O R M A T I O N B U L L E T I N V'A • Intelligent, self- diagnostics • On -site maintenance alert • Field replaceable optical chamber • Low - profile design • Plug -in terminal block • Advanced false alarm immunity 4491448 SERIES Self - Diagnostic, Four. Wire, Photoelectric Smoke Detectors Model numbers: 449AT, 449C, 449CT, 449CRT, 449CST, 449CSTE, 449CSRT, 449CSRH, 449CTE ®L FM ULC LISTED APPIKWW California State Fire Marshal Approved MEA (New York City) Approved ULC model numbers: 448AT, 448C, 448CT, 448CST, 448CSRH, 448CTE The ESL 449/448 Series self- diagnostic, four -wire smoke detectors continually monitor their own sensitivity and operational status, and provide a visual trouble indication if they drift out of sensitivity range or fail internal diagnostics. This unique, patented technology meets NFPA 72 field sensitivity testing requirements without the need for external meters. Additional diagnostic information is activated by applying a magnet near the detector's integral reed switch. This initiates a self- diagnostic routine and provides visual indication of sensitivity level, or if service is required. This series is easily cleaned by simply replacing ESL's proprietary field- replaceable optical chamber. All models are designed to reduce false alarms from dust, insects, RFI, and external light. An integral combination rate -of -rise and fixed 135 °F (57 °C), 50 -foot rated, heat sensor is available with all "T" model detectors (see selection guide), allowing latching of the alarm for either smoke or heat. The 449CSRH includes an isolated alarm output for heat and activates an internal non - latching sounder (local alarm) for smoke, making it ideal for motel /hotel and dormitory rooms where smoking is permitted. continued ESL 449 Series Smoke Detectors Architectural and Engineering Specifications The ESL 449 Series low - profile, self- diagnostic, four -wire smoke detectors work on the light scattering principle. A pulsed infrared light- emitting diode serves as the light source, and a high -speed photodiode as the sensing element. When the amount of light reflected onto the photodiode reaches the sensitivity setting, the smoke sampling rate increases. Three (3) successive smoke sensings above the sensitivity setting are required to sound an alarm. This design has superior protection against false alarms caused by dust, insects, RF and ambient - light. A confirmed alarm causes the normally flashing power indicator LED to light continuously and the alarm relay to operate. A trouble indication is automatically displayed by flashing the LED every second. This meets NFPA 72 field sensitivity testing requirements. An internal 85 dB horn (available in "S" models) emits a temporal 3 when the detector alarms and a steady tone when power polarity is reversed. Product Data Feature Sensitivity .................. ............................... 3.1 - 1.0 % /ft. (max.) Isolated Fixed Temp. 3.1 + 0.50 % /ft. (min) Operating temp. range ............... 32 °F to 120 °F (0 °C to 50 °C) Operating humidity range ..... ............................... 0 to 95% RH Minimum voltage - C, CT, CRT, CST, CSRT, CSRH , CSTE.......................................... ............................... 8.5V - AT ............................................... ............................... 5.1V Maximum voltage - C, CT, CRT, CST, CSRT, CSRH, CSTE............................................ ............................... 33V AT................................................. ............................... 27V Maximum ripple (peak to peak) ......... ............................... 10% Typical average standby current .......... ...........................70µA - CSTE ......................................... ............................... 23mA Typical alarm current - C, CT and AT ............................ 15mA - CRT ............................................... ...........................31mA Selection Guide The proprietary optical sensing chamber is field replaceable, allowing quick and easy cleaning and maintenance. Models with auxiliary relays are approved for releasing service. This low profile product is equipped with a hinged cover, a concealed tamper- resistant latch, and insect screens. Wiring terminates in plug -in, clamp -type screw terminals. Detectors mount to a standard single -gang electrical box, a four -inch octagonal, four -inch square electrical box, or WIREMOLD 5739 fixture box. Smoke Detector Spacing On smooth ceilings (as defined in NFPA 72), spacing of 30 feet (9.1 meters) may be used as a guide. Other spacing may be used depending on ceiling height, high air movement, and other conditions or response requirements. 185'(4170 0 - CST ........................................... ............................... 40mA -CSRT, CSRH, CSTE ................. ............................... 51 mA Typical avg. polarity reverse current - CST, CSRT, CSTE, and CSRH ..... ...........................10mA Sounder specifications .......... ............................... 85 dB at 10' Heat detector specifications fixed temperature ...... ............................... 135 °F (57.2 °C) rate of rise .... 15 °F /min. & >105 °F (8.3 °C /min. & >40.6 °C) Auxiliary relay contacts 2A @ 28 VDC or 120 VAC (resistive) Alarm contacts ........................ 500 mA @ 36 VDC (resistive) Field wiring size ................... ............................... 14 - 24 AWG Packaging ....................... 10 detectors are packed in a carton Color .......................... ..........................white cover /white base with UV inhibitor to prevent yellowing Listing .............................. UL 268, ULC FM, CSFM and MEA Designator Feature Description H Isolated Fixed Temp. Isolated fixed 135 °F (57 °C) and rate of rise heat detector, independently trips the LED and alarm and Rate of Rise output. Smoke detector activates internal sounder (local alarm) and auxiliary relay, but Heat Detector does not latch. Approved as both single station smoke alarm and system heat detector. Ideal for hotel, motel and dormitory rooms where smoking is allowed. R Auxiliary Relay Used to activate other devices such as elevator recall, door holders, strobes, etc. Listed for releasing service. S Built -in Sounder 85dB built -in sounder alarms when smoke is detected or when power wiring polarity is reversed. T Intergrated Fixed Intergrated Fixed 135 °F (57 °C) temperature and rate of rise heat detector. Temp. and Rate of Either heat detector or smoke detector can trip and latch LED and alarm protection. Rise Heat Detector relay outputs. E Built -in end of line Relay is normally energized and will trip with loss of power. Can also provide notification power supervision relay when detector needs maintenance. i n t e r l o g i ►,'i•. PH 503.692.4052 USA & Canada: 800.547.2556 Technical Service: 800.648.7424 Fax Back: 800.483.2495 wwwsentrol.com www.inteflogixsecufity.com E -3965 Rev B -1101 92001 Inwbgm Inc. Intarlogm Caddz, ESL, ITI and Smtrol are trademarks of krterlogmlm. SYSTEM SENSOR` 5600 Series Mechanical Heat Detectors System Sensor's 5600 series mechanical heat detectors offer a low -cost means for property protection against fire, and for non -life- safety installations where smoke detectors are inappropriate. Features • Multiple configurations for installations: - Single- and dual- circuit models - Fixed temp and combination fixed- temp /rate -of -rise 1357 or 194 °F ratings. • Plain housing for residential installations (Model 5601 P) • Easy -to -use terminal screws A broad range of back box mounting options: - Single gang - 3.5 "and 4- Octagonal -4- square with square to round plaster ring • Reversible mounting bracket Agency Listings & <F M > MEA LISTED APPROVED approved 0 S'!ic° ,otens my:,t i. 7270- 1101:221 ri Multiple configurations. The 5600 series offers a full -line of configurations to accommodate a broad range of applications. Both single- and dual- circuit models are available for low- and high - temperature ratings with either fixed temperature or combination fixed temperature /rate -of -rise (ROR) activation. The ROR element of the fixed /ROR models is restorable to accommodate field- testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single -gang and octagonal back boxes. And these models accommodate four - square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both Flush- and surface -mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed /rate -of -rise units are marked FX /ROR.The 5600 series also provides a post - activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. ifications Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single- circuit or a dual - circuit type, normally open. The detector shall be rated for activation at either 135 °F (57'C) or 194 °F (90 °C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature /rate -of -rise thermal sensor. The rate -of -rise element shall be activated by a rapid rise in temperature, approximately 15 °F (8.3 °q per minute. The detector shall include a reversible mounting bracket for mounting to 31/2 -inch and 4 -inch octagonal, single gang, and 4 -inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14 -22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate -of -rise element of combination fixed temperature /rate -of -rise models shall be restorable, to allow for field- testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Maximum Installation Temperature 5601 P, 5603,562 1, and 5623: 100 °F (38 °C) 5602, 5604, 5622, and 5624:150'F (65.6 °C) Operating Humidity Range 5 to 95% RH non - condensing Dimensions with mounting bracket Diameter: 4.57 inches (I 1.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 56011? 5603, 5621, and 5623: 135 °F (57 °C) 5602, 5604, 5622, and 5624: 194oF (90 °C) Weight 6 oz. (170 grams) Rate -of -Rise Threshold 15 °F (83 °C) rise per minute (models 5601 P, 5602, 5621, and 5622 only) Mounting 3'h -inch octagonal back box 4 -inch octagonal back box Single gang back box 4 -inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage /Contact Ratings 6- 125VAC / 3A 6 -28VDC / 1 A 125VDC / 03A 250VDC / O.1 A Input Terminals 14 -22 AWG u \l 5601P 5602,5622 5603,5623 5604,5624 5621 Orderina Information 5601 P Single None 135 °F (57 °C) Fixed Temperature/ Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194 °F (90 °C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135 °F (57 °C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194 °F (90 °C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135 °F (57 °Q Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194 °F (90 °C) Fixed Temperature/ Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135 °F (57 °C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 "NOTE: Refer Dual to NFPA72 Lettering guidelines for spacing 194 °F (90 °C) Fixed Temperature reductions when ceiling heights exceed 10 feet. 25 feet x 25 feet (7.62m x 7.62m) SYSTEM 111 6 SY.— 5e�5oi. 3825 Ohio Avenue • St. Charles, IL 60174 Prod— spwfiu10 ssuq«Irochage, mo,noo \Asicsyv mum «comfo, �y SENSOR Phone: 800- SENSOR2 • Fax: 630-377-6495 cuff— Vc'°"'"fi tio"- 'o`'ud'"9'n„re " "� nndit,ci ` h t A05- 0351 - 002. 11/06•.1676 Installation Instructions 4193SN Serialized Interface Module (SIM) The 4193SN is a serialized two -zone expander used to connect alarm sensing devices to controls which support serial number polling loop devices (i.e., Vista - 40, Vista -50P, and Vista -100). The 4193SN can be configured as one supervised zone (10K EOLR) and one unsupervised zone, or two unsupervised zones (normally closed devices only). Consult the control panel installation instructions for programming information. Electrical Specification: Voltage: 7 -11VDC (as supplied from the Ademco control panel for multiplex polling loop) Current: 1.5mA RED ( +) WHITE (LOOP 1) SUPERVISED EOLR 10K YELLOW (LOOP 1) UNSUPERVISED POLLING LOOP GREEN (LOOP 2) UNSUPERVISED BLACK ( -) I I BLACK (COMMON) Wiring Diagram VL e LISTED 5789 For Fire Applications: The 4193SN must be mounted inside the control panel cabinet or inside a UL- Listed junction box. Loop 1 must be used in the supervised configuration for Fire. Loop 2 may be used for Burglary. For UL Burglary Applications: If using an unsupervised zone of the 4193SN, the unit must be mounted within 3 feet of the alarm initiating device, with no intervening barriers. ADEMCO 4193SN Serialized Interface Module (SIM) • For connecting alarm sensing devices and switches to Ademco multiplex polling loop Quantity: 1 ea. Requires control panel with SERIAL NUMBER device capability (e.g. Vista -40, etc.) Consult control panel instructions for compatibility (C L v LISTED S789 N7644V2 Rev. B 11/96 5192S D/5192S DT V -PLEV SMOKE DETECTOR The Honeywell 5192 Series low profile, addressable V -Plex smoke detectors deliver state -of- the -art features and benefits in a cost - effective package. These detectors are designed to provide open area coverage and are compatible with Honeywell's VISTA controls supporting V -Plex technology. An LED on the detector will blink periodically during normal conditions, remain on steady during alarm and cease to pulse if the chamber is out of acceptable sensitivity range. An extremely powerful feature available within the 5192 Series is the Automatic Maintenance Alert/Reporting capability — a feature normally found in today's high end analog addressable systems. The detectors continually monitor their own sensitivity levels in addition to the basic normal and alarm conditions. These HIGH and LOW SENSITIVITY signals are communicated back to the FEATURES • Low profile design • V -Plex addressable loop device • Automatic maintenance reporting APPLICATIONS Honeywell control, via the V -Plex addressable loop, to indicate locally and at the central station that the detector may not be able to detect smoke or may false alarm. This feature works with VISTA -32171B, 12813P, 128FBP, 2506P, 250FBP, 40, 50P, 100 -24 and FAP FA1600C, FA1660C and FA1700C. More important is the cost saving associated with Automatic Maintenance Reporting. The feature is an approved alternate to NFPA 72 field sensitivity calibration testing that require external test meters. This eliminates the need to schedule inspections to determine detector sensitivity /viability. Another important benefit of these V -Plex (addressable) smoke detectors is their ability to operate on existing wiring. There is no need to run special twisted pair, data grade or shielded wires, providing you with the right choice for all your retrofit applications. That equates to cost savings in time and materials! • Available with integral heat sensor • Simple 2 wire installation • DIP switch or serial number programmable • Lines on existing or conventional wiring The 5192 Series smoke detectors are designed to provide open area coverage and are well suited for most fire detection applications. These smoke detectors are compatible with all Honeywell VISTA Fire and Burglary controls that support V -Plex addressable loop technology. These agency listed alarm initiating devices support most commercial and residential applications. They are suited for use in museums, hospitals, day care centers, retail stores, strip malls, schools, libraries, fast food chains, medical or professional office suites and in factory and warehouse environments. 5192SD/5192SDT V- PLEXTM SMOKE DETECTOR SPECIFICATIONS Installation The 5192 Series smoke detectors are supplied with a convenient mounting bracket that allows the detector to be mounted to a variety of electrical junction boxes. A removable terminal block, that accepts 14 to 22 gauge wire to provide easy wiring connections. The detectors are designed to meet all applicable requirements for UL Commercial and Residential Fire installations as well as NFPA 72 requirements when installed in compliance with the National Electric Code and approved/listed control panels. W� oza- Fa J U J Q J ZZ =Z - O UJ � DIP m F Q SWITCH REMOVABLE U d TERMINAL BLOCK >0 U U Wiring diagram for 5192SD /SDT smoke detector Compatibility These smoke detectors are compatible with all VISTA control panels that support V -Plex (addressable) polling loop technology. The detectors support DIP switch or serial number addressing. DIP switch configuration are compatible with 5140XM, VISTA -40, and VISTA -50P controls. ORDERING Serial number addressing is supported on VISTA -32FB, 1286P, 128FBP, 25013P, 250FBP, 100 -24 and FAP FA1600C, FA1660C and FA1700C controls. (Refer to control panel and smoke detector installation instructions for details.) Automatic Maintenance Reporting Compatibility The automatic maintenance feature is compatible with the following control panels: — VISTA -32FB — VISTA -128BP — VISTA- 128FBP — VISTA -250BP — VISTA- 250FBP — FA1600C — FA1660C — FA1700C The automatic maintenance may be disabled for all other controls that do not support this feature. Refer to control panel and smoke detector Installation Instructions for details. Electrical: • System voltage range: 7 -14 V Standby current (maximum @ 12V): — LED off: 1.2mA — LED on: 2.8mA Mechanical: • Diameter: 5.5 inches (140mm) (including mounting bracket) • Height: 1.7 inches (43mm) (including mounting bracket) • Weight: 5.3 ounces (150 grams) Environmental: • Installation temperature range: 32° to 100 °F (0° to 38 °C) • Installation humidity range: 10% to 93% RH, non - condensing • Heat sensor (5192SDT only): 135 °F fixed temperature electronic thermistor • EMI: Meets or exceeds the following requirements: — FCC Part 15, Class B Device — IEC EMC Directive Agency Listings • UL268 Commercial System Smoke Detector • Meets UL 217 Requirements for Residential 5192SD Addressable Photoelectric Smoke Detector 5192SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor For more information: www.honeywell.com /security/hsc Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 U5192/D May 2009 www.honeywell.com m 2009 Honeywell International Inc. Honeywell 5808W3 PHOTOELECTRIC SMOKE /HEAT DETECTOR WITH BUILT -IN WIRELESS TRANSMITTER Honeywell Honeywell's 5808W3 is a 3V lithium powered, Since there are no holes to drill or wires to run, you can photoelectronic smoke /heat detector with a built -in preserve the beauty of the building while protecting it. The wireless transmitter. It is intended for use with any 5808W3 is an ideal smoke detector for those difficult to wire 5800 Series Wireless Receiver/Transceiver for residential locations, applications where room aesthetics are critical, or installations (for commercial installations, the 5881 ENHC where hazardous materials exist. or the 5883H receiver is required). The transmitter can send alarm, tamper, maintenance (when control panels are equipped to process maintenance signals) and battery condition messages to the system's receiver. Smoothing algorithms minimize nuisance alarms by smoothing out short term spikes from dust and smoke — virtually eliminating nuisance alarms. FEATURES • Improved Robust RF Field Strength The distance between the detector and receiver has been significantly increased without the need for a repeater • Smoothing Algorithms Mathematical calculations in the detector's software that minimize nuisance alarms by smoothing out short term spikes from dust and smoke • Smart Check A signal is sent to the control panel when the detector requires cleaning. This allows a regular, non - emergency service call to clean the detector before it goes into alarm. All models also feature a restorable, built -in, fixed temperature (135 °F) thermal detector that is also capable of sensing a pre- freeze condition if the temperature is below 41'F • Drift Compensation Virtually eliminates nuisance alarms from long -term dust build -up by automatically adjusting the detector's sensitivity • Removable Detector Cover and Chamber Top The technician is able to quickly and easily clean the detector chamber without disassembling the detector head • Approved UL Listings for Residential and Commercial Applications Both residential and commercial installation requirements are met • Additional LED Status Indicators Identifying between alarm or trouble conditions is a snap with green and red LED status indicators. A green LED denotes a normal condition while the red LED indicates abnormal conditions. • Easy -to- install Mounting Base The sturdy mounting base allows the detector to be more easily installed on uneven surfaces (i.e. stucco). The mounting base has larger mounting ports, which accommodate drywall anchors for easy surface mounting. ADDITIONAL FEATURES: • Utilizes one long -life 3V lithium battery • Microcontroller runs on a 4.0 MHz clock • Horn operates at 3.3 KHz with sound pressure level of 85 dBA at 10 feet • Built -in wireless transmitter, temporal code 3 sounder • Maintenance signal fully complies with the sensitivity test requirement specified in NFPA 72, 7 -2.2 and is approved by UL 5808W3 PHOTOELECTRIC SMOKE /HEAT DETECTOR WITH BUILT -IN WIRELESS TRANSMITTER SPECIFICATIONS • Dimensions - Diameter: 5.3 "', Height: 2.30" • Weight - 8.5 ounces (without batteries) • Operating Temperature - 32 -100° F (0 -37.8° C) • Humidity Range - 0% to 95% RH, non - condensing • Air Velocity - 1,000 ft. /min. max. • Operating Voltage - 2.5- 3.6VDC • Standby Current - 8.5 mA avg. • Alarm Current - 35 mA max. ' With adapter bracket (4.9" without mounting base) tReplacement batteries include Duracell D1_123A, Sanyo CR123A, Panasonic CR123A, or ADEMCO 466 ACCESSORIES (sold separately) SENS -RDR Infrared Sensitivity Reader Reduce testing time with the handheld SENS -RDR infrared sensitivity reader. The reader simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration. The SENS -RDR eliminates the need for magnets, voltmeters and ladders. • Power Source - One 3V CR123A lithium Batteryt • Audible Output - 85 dB min. at 10 ft. • Fixed Temperature Heat Sensor - 135° F Fixed • Agency Listings - UL268 - Commercial and Residential RT Removal Tool Simplifies the attachment and removal of the detector head to the mounting base; it may be attached to a threaded extension pole or broom handle thereby eliminating the need for ladders. ORDERING 5808W3 Photoelectric Smoke /Heat Detector with Built -in Wireless Transmitter Accessories sold separately: SENS -RDR Hand -held Sensitivity Reader RT i3 Removal Tool used for easy installation and removal of head from base Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com U5808W3DS /D September 2008 0 2008 Honeywell International Inc. Honeywell 5809 WIRELESS HEAT DETECTOR Honeywell's 5809 wireless fixed heat and rate -of -rise temperature sensor offers expanded fire detection and installation flexibility. It is ideal for hard to wire locations and applications that require more than smoke detection. With no wires to run, the 5809 is fast and easy to install. The 5809 combines both rate -of -rise and fixed temperature sensors. Fires typically cause a rapid rise in temperature in the FEATURES • Contains a built -in transmitter which can send alarm, supervisory and battery condition messages to the system's receiver /control unit • Powered by a three -volt lithium Honeywell surrounding area. The 5809's rate -of -rise thermostat senses the rise in temperature and signals an alarm if the increase is 15° or more per minute. A built -in fixed temperature sensor will also signal an alarm if the environmental temperature rises above 135 °F. The 5809 is UL Listed (UL521) and CSFM approved for commercial and residential applications. battery. If the battery voltage gets too low, the 5809 sends a low battery signal to the control panel • Features a tamper switch, which causes a trouble signal to be sent to the control if the unit is removed from the mounting base • UL Listed for Commercial (when using 5881 EH Receiver) or Residential applications .M ......... K surrounding area. The 5809's rate -of -rise thermostat senses the rise in temperature and signals an alarm if the increase is 15° or more per minute. A built -in fixed temperature sensor will also signal an alarm if the environmental temperature rises above 135 °F. The 5809 is UL Listed (UL521) and CSFM approved for commercial and residential applications. battery. If the battery voltage gets too low, the 5809 sends a low battery signal to the control panel • Features a tamper switch, which causes a trouble signal to be sent to the control if the unit is removed from the mounting base • UL Listed for Commercial (when using 5881 EH Receiver) or Residential applications 5809 WIRELESS HEAT DETECTOR SPECIFICATIONS: • Power: - 3V lithium battery (Duracell DL123A, Panasonic CR123A, Sanyo CR123A, Varta CR123A) - Operating temperature: 40° to 140oF (6° to 60 °C) - Rate -of -rise temperature: 15 °F (8 °C) increase per minute (NOTE: Rate -of- rise sensor does not operate above 38 °C) Fixed temperature: 135oF (57 °C) Maximum spacing: 50 ft x 50 ft UL, 30 ft x 30 ft FM (refer to National Fire Alarm Code Standard NFPA 72 for application requirements) - Dimensions: 4.4" diameter /2/2" deep • Agency Listings: - UL 521 Listed for Commercial (when using 5881 EH Receiver) or MOUNTING THE DETECTOR: - You can mount the 5809 on a wall or ceiling within the protection area: - Wall mounting: Mount the detector 4" 6" from the ceiling Ceiling mounting: Mount the detector at least 4" from any wall. Make sure the normal ceiling temperature will not exceed 100 °F (37.8° C). TESTING THE DETECTOR: The test procedure should be performed to determine a good RF transmission path and again after installation is completed. CAUTION: The fixed temperature sensor is intended for one -time use. Prolonged heat during testing can damage the unit. If used carefully following the instructions described below, the heat from a portable hair dryer can be used to test the unit. If the round disk on top of the detector detaches, the detector must be replaced. - Activiate the control panel's test mode ORDERING 5809 Heat Detector - Refer to NFPA Standard 72 for detector spacing and other requirements. Maximum spacing for UL installations is 50' x 50' - Avoid mounting the detector near heat generating devices (e.g. ovens, heat vents, furnaces, boilers) IMPORTANT: Heat detectors should Residential applications • Wireless Transmission Path Test: - A good RF transmission path must be established from the proposed mounting location before permanently installing the detector. To determine that there is a good signal reception from the proposed location, perform the test procedure described in the installation instructions procedure. be used for property protection. Reliance should not be placed soley on heat detectors for life safety. When life safety is involved, smoke detectors MUST also be used. Detectors must not be painted. - Use either method (a) or (b) or activate - Exit the control's test mode the detector FCC ID: CFS 8DL 5809 (a) Press and release the activation button on the PC board assembly OR (b) Holding a portable hair dryer about 12 to 18 inches away from the detector, turn the dryer on and aim the warm air at the side of the detector. CAUTION: Aiming the dryer directly at the round disk on the detector can damage the unit to be replaced. - The system's keypad should beep and the detector's ID should be displayed Honeywell Security & Custom Electronics Honeywell 2 Corporate Center Drive Suite 100 P.O. 9040 Melville, NY 11747 www.honeywell.com This device complies with part 15 of FCC rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. U58MD October 2007 ® 2007 Honeywell International Inc. Honeywell * ** *DISARMED * * ** READY TO ARM 6160 -- ALPHA DISPLAY KEYPAD WITH DOOR ATTACHED The 6160 Deluxe Keypad is easy to install and simple to use. The attractive white console blends with any decor and features a contoured, removable door that conceals illuminated soft -touch keys. The 6160 also features a new larger and brighter 32- character display with easy -to -read plain - English status messages. FEATURES • Large, easy -to -use keypad • Keys continuously backlit for greater visibility • Speaker with audible beeps to indicate: System status Entry/exit delay Other alarm situations SPECIFICATIONS Physical • 5- 5/16 "H x 7 -3/8 "W x 1- 3/16 "D (135mm x 190mm x 30mm) Current • Standby -40mA • Activated Transmission- 1 60mA IS ARMED:+::+::+:* READY TO ARM r 0 0 - WITHOUT DOOR The oversized function keys are easily accessed even when the keypad door is closed, and can be programmed for fire, burglary, personal emergencies and other operations. Colored self- adhesive labels are included. • Zones and system events displayed in plain English • No confusing blinking lights • Four programmable function keys Wiring • - (Black): Ground • + (Red): +12 VDC (Aux. Power) • D1 (Green): "Data in" to control panel • DO (Yellow): "Data out' from control panel ORDERING 6160 Alpha Display Keypad Honeywell Security & Custom Electronics Honeywell International Inc. PO Box 9035 Syosset, NY 11791 www.honeywell.com C006010 v6t60iD September 2006 0 2006 Honeywell International Inc. • System functions clearly labeled • Functions performed by just entering security code plus command • White with removable door blends with any decor Compatibility • Fully compatible with all VISTA controls. Honeywell �� SYSTEM �A SENSOR' Selectable- Output Horns, Strobes, and Horn Strobes SpectrAlert* Advance selectable - output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. Features • Plug -in design with minimal intrusion into the back box •Tamper- resistant construction Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela Field- selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall and ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with existing SpectrAlert products Compatible with MDL sync module Agency Listings SIGNALING UL F M LISTED X5512 (strobes: APPROVED r e m S s t e m S a n s o r kJ The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE - printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug -in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time - consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. MEA approved 7125- 1653186(iodoor strobes) 7125- 16S318S (hom strobes, MEA452 -05 -E chime strobes) 7135- 16S3.189 (horns, chimes) r e m S s t e m S a n s o r kJ The SpectrAlert Advance series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE - printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug -in designs with minimal intrusion into the back box, which make installations fast and foolproof while virtually eliminating costly and time - consuming ground faults. Furthermore, a universal mounting plate with an onboard shorting spring tests wiring continuity before the device is installed, protecting devices from damage. In addition, field - selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections enables installers to easily adapt devices to suit a wide range of application requirements. SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 1'/rinch back box, 4 -inch octagon back box, or double -gang back box Two -wire products shall also mount to a single -gang 2 x 4 x 17 /s -inch back box A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync -Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12- volt -rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24 -volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15,15/75, 30 75,95, 1 I Q 115,135,150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a PA6 x 411,6 x 2' /8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physkal/Electrical Specifications Standard Operating Temperature 32 °F to 120 °F (0°C to 49 °C) Humidity Range 10 to 93% non - condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8- diameter x 2.5 -high (173 mm diameter x 64 mm high) Wall -Mount Dimensions (including lens) 5.6 -L x 4.7 -W x 2.5- D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6 -L x 4.7 -W x 1.3 -D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Back Box Skirt Dimensions (BBS -2, BBSW -2) 5.9 -L x 5.0 -W x 2.2 -D (151 mm L x 128 mm W x 56 mm D) Ceiling -Mount Back Box Skirt Dimensions (BBSC -2, BBSCW -2) 7.1- diameter x 2.2 -high (180 mm diameter x 57 mm high) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR -H5, TRW -HS) 5.7 -L x 4.8 -W x 0.35 -D (145 mm L x 122 mm W x 9 mm D) Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC -HS, TRCW -HS) 6.9 "diameter x 0.35" high (175 mm diameter x 9 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. P05 -0395-W7 UL Current Draw Data UIL Max. Strobe Current Draw (rnA RMS) 8 -17.5 Volts 16 -33 Volts Candela DC FWR DC Standard 15 123 128 66 Candela Range 15/75 142 148 77 30 NA NA 94 8 -17.5 Volts 16 -33 Volts FWR Sound Pattern dB DC FWR DC FWR 71 Temporal High 57 55 69 75 81 Temporal Medium 44 49 58 69 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non - temporal High 57 56 69 75 95 NA NA 181 176 Non - temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 Candela Range 150 177 185 DC Input NA NA 228 207 Coded Medium 44 51 56 69 NA NA NA NA NA NA Offm 8 -17.5 Volts 246 220 Coded Low 40 46 52 50 281 251 286 258 Standard Candela Range (11 S-1 I S cd) 16 -33 Volts 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - Temporal High 141 152 91 100 116 176 201 221 229 Non Temporal Medium 133 145 75 85 102 163 187 207 216 Non - Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input 242 259 293 299 Non Temporal Medium 219 232 262 267 Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non Temporal High 142 161 103 112 126 181 203 221 229 Non Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal • 80 90 105 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, High Candela Range (135 -185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - Temporal High 255 270 303 309 Non Temporal High 233 248 275 281 Non - Temporal Medium 242 259 293 299 Non Temporal Medium 219 232 262 267 Non Temporal Low 238 254 291 295 Non- Temporal Low 214 229 256 262 Horn Tones and Sound Output Data 8 -17.5 16 -33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non - Temporal High 82 82 88 88 93 92 100 100 5 Non Temporal Medium 78 78 85 85 90 90 98 98 6 Non Temporal Low 75 75 81 81 88 84 96 92 7r Coded High 82 82 88 88 93 92 101 101 8r Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 TSettings 7, 8, and 9 are not available on 2 -wire horn strobe. A05 -0395 -007 SpectrAlert Advance Dimensions Di 4 J Wall-mount horn strobes Ceiling-mount horn strobes I 7.1' 2.25 -1 5.05 — 2.23:1 Dia. o 0 QS 59 O O Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Wall Horn Strobes Ceiling Strobes P2R *t 2 -Wire Horn Strobe, Standard cd *, Red SCR Strobe, Standard cd, Red P2RH* 2 -Wire Horn Strobe, High cd, Red SCRH Strobe, High cd, Red P2W* 2 -Wire Horn Strobe, Standard cd, White SCW* Strobe, Standard cd, White P2WH* 2 -Wire Horn Strobe, High cd, White SCWH Strobe, High cd, White P4R* 4 -Wire Horn Strobe, Standard cd, Red Horns P4RH 4 -Wire Horn Strobe, High cd, Red HR Horn, Red P4W 4 -Wire Horn Strobe, Standard cd, White HW Horn, White Wall Strobes Accessories SR *t Strobe, Standard cd, Red BBS -2 Back Box Skirt, Wall, Red SRH *t Strobe, High cd, Red BBSW -2 Back Box Skirt, Wall, White SW* Strobe, Standard cd, White BBSC -2 Back Box Skirt, Ceiling, Red SWH* Strobe, High cd, White BBSCW -2 Back Box Skirt, Ceiling, White Ceiling Horn Strobes TR -HS Trim Ring, Wall, Red PC2R* 2 -Wire Horn Strobe, Standard cd, Red TRW -HS Trim Ring, Wall White PC2RH 2 -Wire Horn Strobe, High cd, Red TRC -HS Trim Ring, Ceiling, Red PC2W*t 2 -Wire Horn Strobe, Standard cd, White TRCW -HS Trim Ring, Ceiling, White PC2WH* 2 -Wire Horn Strobe, High cd, White PC4R 4 -Wire Horn Strobe, Standard cd, Red PC4RH 4 -Wire Horn Strobe, High cd, Red PC4W 4 -Wire Horn Strobe, Standard cd, White Notes: * Add %P'to model number for plain housing (no •FIRE'marking on cover), e.g., P2R -P. t Add' -SP'to model number for "FUEGO' marking on cover, e.g., P2R -SP. *"Standard cd"refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. SYSTEM3825 Ohio Avenue • St. Charles, IL 60174 Prod Y7zoo9System sensor 4 SENSOR" masons s—t n,rnd drag he wace � offt s u si—tn to Phone: 800 SENSOR2 •Fax: 630 - 377 6495 ""tP°a �' "� °°0395- 07-410w#2132 "w"n a'a lee` A05 -0395-007.4/09•Y1131 0-: SYSTEM �� SENSOR" Mini -Horns The SpectrAlert'Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. Features 12 and 24V operation • High and low volume settings -Temporal and non - temporal tones • Mounts to single gang back box • Compatible with MDL sync module Mechanically and electrically compatible with PA400 series Mini - Alert- sounders Agency Listings & FM MEA` LISTED APPROVED approved I.; I i „ .. .._ I L 71351653:196 S s t e S e The MHR and MHW mini -horns operate at 12 and 24 volts and are ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired.The mini -horns offer high and low volume settings, and temporal or non - temporal tones. The horns can be mounted to single gang back boxes for aesthetically sensitive applications. Synchronization is also provided when using the MDL module. The MHR and MHW mini -horns can operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified, unfiltered power supply. They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systems. trAlert" Advance Mini -Horn Specifications Mini -horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a single gang back box. Mini - horn shall he listed to Underwriter's Laboratories Standard U1464 for fire protective signaling systems. Mini -horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. When used with the Sync-Circuit' Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Dimensions 4.61 x 2.9W x .45"D Weight 2.67 oz. Operating Temperature Range 32 °F to 120 °F (0 °C to 49 °Q Mounting Surface: single -gang back box Flush: 4"x 4" BBD deep back box (23/4 "deep) Input Terminals 12 to 18 AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8 -33 Operating Voltage with MDL 9 -33 UL Sound Output and Current Draw Data Switch Setting Pattern Output Level 8 -17.5 VDC 8 -17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16-33 VDC 16 -33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non - temporal High 72 71 75 74 80 79 4 Non- temporal Low Sounder Current Draw 70 69 73 72 78 77 Switch Position Sound Pattern Volume 8 -17.5 Volts DC FWR 16 -33 Volts DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non - temporal High 22 17 29 25 4 Non- temporal Low 17 13 21 19 Ordering Information Description Part No. MHR Mini -Horn, Red MHW Mini -Horn, White SYSTEM 021x17 System mA nc,. 3825 Ohio Avenue • St. Charles, IL 60174 croa�a���4ra "s s�gecerocnz "ye,�man��e.�n�tsne�,u "ro�comror �1 SENSOR Phone: 800- SENSOR2 • Fax: 630-377-6495 " ""`�""s " "' "'° "x"°0414 °W-1/07.917" ""an� dam sn� A05- 0414 - 000.1/07•/1743 �p �ul/ER����%irfl Rechargeable Sealed Lead -Acid Battery Mpp L P5 1MjL) F1 12 YYvH 7ANmV. W. PS -1270 12 Volt 7.0 Amp. Hrs. Features: • Absorbent Glass Mat (AGM) technology for superior performance. • Valve regulated, spill proof construction allows safe operation in any position. • Power /volume ratio yielding unrivaled energy density. • Rugged plastic case and cover • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified. • U.L. recognized under file number MH 20845. W PERFORMANCE SPECIFICATIONS Nominal Voltage ........................................................................................................................ ............................... 12 volts (6 cells in series) Nominal Capacity 20 hour rate (350mA to 10.50 volts) ....................................................................................................... ............................... 7.0 A.H. 10 hour rate (650mA to 10.50 volts) ....................................................................................................... ............................... 6.5 A.H. 5 hour rate (1.2A to 10.20 volts) ........................................................................................................... ............................... 6.0 A.H. 1 hour rate (4.5A to 9.00 volts) ............................................................................................................ ............................... 4.5 A.H. 15 min rate (14A to 9.00 volts) .............................................................................................................. ............................... 3.5 A.H. ApproximateWeight ..................................................................................................................... ............................... 5.70 pounds (2.59 k9) Energy Density (20 hour rate) ............................................................... ............................... 1.43 Watt- hours /cubic inch (87.3 Watt- hours /I) Specific Energy (20 hour rate) .................................................................. ............................... 14.7 Watt-hours /pound (32.4 Watt-hours /kg) Internal Resistance (Fully Charged Battery) .................................................................... ............................... 22 milliohms (approximately) Maximum Discharge Current ( < 7 Min.) ..................................................................................................... ............................... 21 amperes Maximum Short- Duration Discharge Current ( < 10 Sec.) ....................................................................... ............................... 70 amperes Terminal configurations ...................... ..........................Quick disconnect tabs, "F1 ": 0.187' x 0.032 ", mate with AMP. INC. FASTON "187" Quick disconnect tabs, "F2 ": 0.250" x 0.032 ", mate with AMP. INC. FASTON "250" Shelf Life — % of nominal capacity at 68° F (20° C) 1 Month .......................................................................................................................................................... ............................... 97% 3 Months ........................................................................................................................................................ ............................... 91% 6 Months ........................................................................................................................................................ ............................... 83% Operating Temperature Range Charge.................................................................................................................................... ............................... -4 °F ( -20 °C) to 122 °F (50 °C) e Discharge ............................................................................................................................... ............................... -4 °F ( -20 °C) to 140 °F (60 °C) Case.................................................................................................................................................................. ............................... ABS Plastic TECHNICAL DATA: Shelf Life and Storage 100 0 O 80 c O 60 T Ei 40 a U 00 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) Life Characteristics in Stand -By Use 100 80 A 60 U 0 40 m 20 m 0 120 100 0 Z, 80 U A 60 U C .c 0 40 v 20 0 0 Ambient Temperature 20'C (68'F) Float Charging Voltage 2.25 - 2.30 V /Cell 0 1 2 3 4 Years Life Characteristics in Cyclic Use of less C4 fore sary ,er A of ach _ SALES & MARKETING IS09001 -2000 CUSTOMERSERVICE 3106 Spring Street 7550 Panasonic Way Redwood City, CA 94063 USA FM39170 San Diego, CA 92154 USA Charging is i Tel: 619-661-2030 Fax: 619-661-3648 national - sales @power- sonic.com www.power- sonic.com customer- service @power- sonic.com 1G „I I I � 1 1­4 ,? necessary ui Discharge Depth 50% Discharge Depth 30% 1. Discharge Current 0.2C (Final Voltage 1.7V /Cell) 2. Charge Current: 0.1C 3. Ambient Temperature: 20 °C to 25 °C (68 °F to 77 °F) Final Voltage 10.5V :±100% of cap is required. 9.60V �\ 9.OV 5 °C Charging br 20% 0% 8.10V (41-F)- use is nece to help rece full capacit, harge may 40 °C (104 °F) 30 °C (86'F) 20'C (68 -F) o res ore full arteries et batteries n flis state. U 00 2 4 6 8 10 12 14 16 18 20 Standing Period (Months) Life Characteristics in Stand -By Use 100 80 A 60 U 0 40 m 20 m 0 120 100 0 Z, 80 U A 60 U C .c 0 40 v 20 0 0 Ambient Temperature 20'C (68'F) Float Charging Voltage 2.25 - 2.30 V /Cell 0 1 2 3 4 Years Life Characteristics in Cyclic Use of less C4 fore sary ,er A of ach 200 400 600 800 1000 1200 Number of Cycles CHARGING Cycle Applications: Limit initial current to 2.1A. Charge until battery voltage (undercharge) reaches 14.40 to 14.70 volts at 68 °F (20 0C). Hold at 14.40 to 14.70 volts until current drops to approximately 70mA. Battery is fully charged under these conditions, and charger should either be disconnected or switched to "float" voltage. "Float" or "Stand -By" Service: Hold battery across constant volt- age source of 13.50 to 13.80 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. NOTE: Due to the self- discharge characteristics of this type of bat- tery, it is imperative that they be charged after 6 -9 months of stor- age, otherwise permanent loss of capacity might occur as a result of sulfation. (v) 14.0 13.0 Q 1 12.0 M 0 11.0 C 10.0 E H 9.0 8.0 PS -1270 Discharge Characteristics X111\ Ilk1 ■�II��II..� ■�I�a11 ■111 ■1 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 40 min. X hrs. Discharge Time Discharge Time vs. Discharge Current 20 15 10 5 t 2 E E 1 i= d E 30 r U N 10 5 _ SALES & MARKETING IS09001 -2000 CUSTOMERSERVICE 3106 Spring Street 7550 Panasonic Way Redwood City, CA 94063 USA FM39170 San Diego, CA 92154 USA Tel: 650-364-5001 Fax: 650-366.3662 - Tel: 619-661-2030 Fax: 619-661-3648 national - sales @power- sonic.com www.power- sonic.com customer- service @power- sonic.com 1G „I I I � 1 1­4 ,? Discharge Depth 100% Discharge Depth 50% Discharge Depth 30% 1. Discharge Current 0.2C (Final Voltage 1.7V /Cell) 2. Charge Current: 0.1C 3. Ambient Temperature: 20 °C to 25 °C (68 °F to 77 °F) 200 400 600 800 1000 1200 Number of Cycles CHARGING Cycle Applications: Limit initial current to 2.1A. Charge until battery voltage (undercharge) reaches 14.40 to 14.70 volts at 68 °F (20 0C). Hold at 14.40 to 14.70 volts until current drops to approximately 70mA. Battery is fully charged under these conditions, and charger should either be disconnected or switched to "float" voltage. "Float" or "Stand -By" Service: Hold battery across constant volt- age source of 13.50 to 13.80 volts continuously. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. NOTE: Due to the self- discharge characteristics of this type of bat- tery, it is imperative that they be charged after 6 -9 months of stor- age, otherwise permanent loss of capacity might occur as a result of sulfation. (v) 14.0 13.0 Q 1 12.0 M 0 11.0 C 10.0 E H 9.0 8.0 PS -1270 Discharge Characteristics X111\ Ilk1 ■�II��II..� ■�I�a11 ■111 ■1 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 40 min. X hrs. Discharge Time Discharge Time vs. Discharge Current 20 15 10 5 t 2 E E 1 i= d E 30 r U N 10 5 0.35 0.7 1.4 3.5 7 14 Discharge Current (A) Physical Dimensions: in. (mm) Terminals l _ T "F7" FASTON tab., 032- LY N gdck diman ® ® ,a„ "F2" FASTON y 0250'.0.0 E:DD 32' quids di ecannad vim. 5.95 (1sl) =1 (704 °F) (68 -F) (32 °F) Tolerances are + /- 0.04 in. ( +/. 7mm) and +1-0.08 in. ( +/. 2mm) for height dimensions. All data subject to change without notice. P'Mr- . A/ /C _ SALES & MARKETING IS09001 -2000 CUSTOMERSERVICE 3106 Spring Street 7550 Panasonic Way Redwood City, CA 94063 USA FM39170 San Diego, CA 92154 USA Tel: 650-364-5001 Fax: 650-366.3662 - Tel: 619-661-2030 Fax: 619-661-3648 national - sales @power- sonic.com www.power- sonic.com customer- service @power- sonic.com 1G „I I I � 1 1­4 ,? Final Voltage 10.5V 70.2V 9.60V �\ 9.OV 40% 20% 0% 8.10V 0.35 0.7 1.4 3.5 7 14 Discharge Current (A) Physical Dimensions: in. (mm) Terminals l _ T "F7" FASTON tab., 032- LY N gdck diman ® ® ,a„ "F2" FASTON y 0250'.0.0 E:DD 32' quids di ecannad vim. 5.95 (1sl) =1 (704 °F) (68 -F) (32 °F) Tolerances are + /- 0.04 in. ( +/. 7mm) and +1-0.08 in. ( +/. 2mm) for height dimensions. All data subject to change without notice. P'Mr- . A/ /C _ SALES & MARKETING IS09001 -2000 CUSTOMERSERVICE 3106 Spring Street 7550 Panasonic Way Redwood City, CA 94063 USA FM39170 San Diego, CA 92154 USA Tel: 650-364-5001 Fax: 650-366.3662 - Tel: 619-661-2030 Fax: 619-661-3648 national - sales @power- sonic.com www.power- sonic.com customer- service @power- sonic.com 1G „I I I � 1 1­4 ,? Aug 05 2005 11:04AM p.1 , r GENESIS CABLE SYSTEMS ' Customer 8pecif"tion ' ;Port Num r: 4108 esorlpti n; 18 AWO 8/C FPL ' ?Canplla UL Standard 1424; NEC.Artiols 780 . "Conawtru on. � ;Conducto,. 18 AWO Solid Seri Copper ; .No, of Co iductors 8 Type Polypropyiens 3 Color;, .Bjk, Red,YMr, Orn, em, B!u , Thioknes 0.0091 nom. } ,pj #rr+etsr 0,052" nom" L„y L 3A" non. Type : F'NC Color, Rid Thiokpo 0,010" nam, al #mrt+rr 01192" nom, Lepirid tl tic Prinq annii wLx ararwe is Awe 0 ju4 rfPs FPL SUN,. UIL Ire ww xxxxx FT , ;rtopwa 4 Tamper; re Ritlnp -20 to 75 °C .Ope>'ign Voltage, 300 Volts max, ' ,�,Capaalta 09 20 OR nom. ; "Ptpo g� Ohms nom, 00 Rbds inos 5:32 Ohms/M' at 20°0 ' Florni Rs ing UL Vertical Tray lam ►moo oa CS: ZI 5002 9 my VZL0-106-Z9Z :x8J 113 SISH39-113AAHOH [a 'd CS: ZI 5002 9 my VZL0-106-Z9Z :x8J 113 SISH39-113AAHOH VISTA-1 28FBPN1 28FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL Designed to integrate seamlessly with CCTV, access control and Honeywell's full range of fire and burglary components, the new VISTA- 128FBP provides the ultimate protection of life and property. The UL Listed commercial fire and burglary control panel supports up to eight partitions and up to 128 zones /points using hardwired, wireless and V -Plex® FEATURES • Eight hardwired zones standard, expandable to 120 V -Plex addressable points /zones or 128 wireless points /zones • Can control eight separate areas independently (8 partitions) • Supports commercial wireless fire and burglary devices • Stores up to 512 events • Accommodates 150 user codes and up to 250 access card holders using VistaKey Honeywell Now UL864 9th Edition Approved addressable technologies. A diverse line of Honeywell initiating devices, notification circuits, communication devices, keypads, RF receivers and relays are also supported. The VISTA- 11 28FBP has been designed to mount quickly and easily in an attack resistant cabinet, and is available in 12V and 24V models. • Supports V -Plex addressable VistaKey access control (1 to 8 doors) • Two on -board notification (bell) circuits delivering 2.3A @ 12V or 3AA @ 24V • Automatic smoke detector sensitivity maintenance testing • Four -wire smoke reset using onboard J2 output trigger • Supports Dynamic Signaling for AlarmNet Communicators • Supports Remote Control via the Internet* • Supports Internet Alarm Reporting* • Supports Graphical User Interface Consoles • Listed to UL864 9th Edition • Upload /download via Ethernet` • Carbon monoxide (CO) zone support * When used with AlarmNet devices. VISTA-1 28FBPN1 28FBP-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL ADDITIONAL FEATURES • Notification Appliance Circuits (two) - Programmable - Temporal code compliant - Individually silenceable • Programmable on -board auxiliary relay • False alarm reduction features: - Exit error logic - Exit delay reset - Cross zoning - Call waiting defeat - Recent close report • Supports commercial hardwired, addressable V -Plex polling loop and wireless zones • Hardwired zones - Provides eight style B hardwired zones - EOLR supervised for Fire and UL burglary installations - Supports N.O. or N.C. sensors - Individually assignable to any eight partitions - Up to 32 two -wire smoke detectors each on zone one and two (64 total) - Up to 50 two -wire glassbreak detectors on zone eight • Patented addressable V -Plex polling loop technology - Supports 120 two -wire zones points - Global polling technology for faster processing - Supervised by panel - Zones individually assignable to partitions, notification circuit (bell) output or auxiliary relay - 4,000 ft. capability without the use of shielded cable - Extender /Isolation bus modules - Eight zone - Class A and B expander module - Eight zone - Class B expander module - One zone supervised contact monitor module • UL Listed wireless expansion - Supports up to 128 wireless zones/points Honeywell - Supervised by control for check -in signals - Tamper protection for transmitters - Individually assignable up to eight partitions - Supports commercial wireless smoke detectors • Access Control integration - Full integration with PassPoint Access Control System Complete Gateway interface of VISTA and access functions • Up to eight doors using VistaKey V -Plex Access Control • Event reporting • Local printer of access or VISTA related events • Communication - Phone mapping by zone response type - Panel operation during download SPECIFICATIONS Applications • Fusing: Battery input, aux. and The VISTA- 128FBP control is well notification (bell) circuit outputs are suited for a variety of applications as protected using PTC circuit protectors. an integrated fire and burglary control. A All outputs are power limited. diverse line of Honeywell initiating devices • Optional 24 -volt power supply, PS 24 supports this extremely powerful control, supplies two 24 VFW, 1.7A full wave Some of the applications supported are: rectified, unfiltered outputs medical and professional buildings, Main Dialer churches or synagogues, office buildings, schools, strip malls, larger residences • Line seize: Double Pole and factory or warehouse environments. . Ringer equiv.: 0.7B Electrical • Primary power: 18VAC @ 72VA Honeywell No. 1451 • Control panel quiescent current draw: 300mA • Backup battery: - 12VDC, 12AH min to 34AAH max - Lead acid battery (gel type) • Alarm power: 12VDC, 1.7A max for each notification (bell) circuit output Total 2.3A @ 12V • Aux, standby pwr: 12VDC, 1 A max • Total power: 2.3A at 12VDC, 3.4A at 24VDC from all sources • Standby time: 24 hours with 1 A standby load using 34AAH battery • Formats: ADEMCO Low Speed, ADEMCO 4 +2 Express, ADEMCO High Speed, ADEMCO Contact ID, Sescoa and Radionics • Dual phone line capability (using 514ODLM module) Cabinet dimensions •18 "Hx14.5 "Wx4.3 "D Environmental • Storage temp: 14° F to 158° F ( -10° C to 70° C) • Operating temp: 32° F to 122° F (0° C to 50° C) • Humidity: 85% RH Honeywell • EMI: Meets or exceeds the following requirements: - FCC Part 15, Class B Device - FCC Part 68 - IEC EMC Directive Agency Listings • UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault • UL611 /1610 Grades A, AA, Central Station • UL365 Grades A, AA Police Connect • UL864 /NFPA72 Local, Central Station and Remote Station • UL985 • Factory Mutual • California State Fire Marshal • MEA • CAN /ULC S304 - Central and Monitoring Station Burglar Alarm Unit • CAN /ULC S527 - Central Unit for Fire Alarm Systems • CAN /ULC S303 - Local Burglar Alarm Unit • CAN /ULC S525 - Audible Signal Appliances VISTA- 1 28FB PN1 28FB P-24 COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL COMPATIBLE DEVICES Auxiliary Devices • 6160CR -2 - Red Alpha Keypad • 4204 - Relay Module, four form C contacts • 4204CF - Two supervised output circuits • 5881 Series RF receiver • 5883H RF receiver • 6220S - System printer used with 4100SM serial module • 6160CR -2 - Red Fire Keypad • 6160 - Burglary Keypad Two -Wire Smoke Detectors Conventional • System Sensor • ESL • DSC Horn /Strobes • System Sensor • Wheelock • Gentex Manual Pull Stations • 514OMPS -1 • 5140MPS -2 V -Plex (Addressable) Devices • 4208U Loop Expansion Module - eight zones • 4101 SN Single Relay/Zone Module Product specifications subject to change. ORDERING • 4208SNF Class A/B Expander Module • 4190SN Remote Point Module - two zones • 4193SN Two -Zone Serial Interface Module • VSI Module • 4293SN One -Zone Serial Interface Module V -Plex Extender /Isolation Modules • 4297 Extender /Isolator Module • VSI Isolator Module V -Plex Smoke Detectors: • 5193SD • 5193SDT V -Plex Passive Infrared Detectors • 998MX • IS2500SN • DT7500SN V -Plex (Addressable) Contacts • 4939SN -WH • 4944SN -WH • 4959SN V -Plex Glassbreak Detectors • FG1625SN Optional 24V Power Supply • PS24 - 24V power supply - 3AA Commercial Wireless Devices • 5808W3 - Photoelectric Smoke /Heat Detector • 5806W3 - Photoelectric Smoke Detector • 5809 - Wireless Heat Detector • 5817CB - Wireless Commercial Transmitter • 5869 - Hold -Up Transmitter • 5881 ENHC - RF Receiver • 5883H - RF Receiver Access Control • VistaKey V -Plex (addressable) Access Control • VistaKey -SK Starter Kit • VistaKey -IX Expansion Kit Alarm Communications • 7845i -ENT - Internet/Intranet Communicator • 7845GSM - Digital Cellular Communicator • 7845i -GSM - Internet and Digital Cellular Communicator • GSMCF /iGSMCF - Commercial Fire Communication Kits (when available) V128FBP -9 Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model V128FBP9 -24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model For more information: www.honeywell.com /security /hsc Automation and Control Solutions Honeywell Security & Communications Honeywell 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 LNSTA128FBPD /D September 2009 www.honeywell.com 0 2009 Honeywell International Inc.