HomeMy WebLinkAboutA11-0016TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970 - 479 -2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT
Permit #: A11 -0016
Job Address: 2672 CORTINA LN VAIL
$0.00 Total Calculated Fees - ->
Status ...:
ISSUED
Location.....:
$0.00 Additional Fees ---------- >
Applied..:
04/22/2011
Parcel No...: 210314203034
$0.00 Total Permit Fee--- - - - - ->
Issued . .:
04/28/2011
Project No
$0.00 Payments ------------------ >
Expires. .:
10/25/2011
OWNER POCKROSS,KEITH M & MIRIAM R
04/22/2011
$0.00
106 UNIVERSITY BOULEVARD 3
* *
* * * * * * * * * * * * * * * * * * * * * * * * * * * **
Approvals:
DENVER
Item: 05600 FIRE DEPARTMENT
CO 80209 -3234
04/27/2011 mvaughan
APPLICANT THUL ELECTRONIC SYSTEMS
04/22/2011
Phone: 970 - 949 -4638
P O BOX 534
AVON
CO 81620
License: 112 -S
CONTRACTOR THUL ELECTRONIC SYSTEMS
04/22/2011
Phone: 970 - 949 -4638
P O BOX 534
AVON
CO 81620
License: 112 -S
Desciption: FIRE ALARM UPGRADE FOR REMODELED SINGLE FAMILY HOME.
Valuation: $4,500.00
************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Electrical --------- >
$0.00 Total Calculated Fees - ->
$456.75
DRB Fee --------- >
$0.00 Additional Fees ---------- >
$0.00
Investigation ---- >
$0.00 Total Permit Fee--- - - - - ->
$456.75
Will Call --------- >
$0.00 Payments ------------------ >
$456.75
TOTAL FEES -->
$456.75 BALANCE DUE--- - - - - ->
$0.00
**************************************************************************************************************
* *
* * * * * * * * * * * * * * * * * * * * * * * * * * * **
Approvals:
Item: 05600 FIRE DEPARTMENT
04/27/2011 mvaughan
Action: AP
CONDITIONS OF APPROVAL
************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADV ANCE BY�TF PHONPAT 970 :4,�Aj?252 FROM 8:00 AM - 5 PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
TOWN OF VAIL, COLORADO Statement
Statement Number: R110000373 Amount: $456.75 04/28/201103:01 PM
Payment Method: Check Init: LC
Notation: 417497 / THUL
ELECTRONICS
-----------------------------------------------------------------------------
Permit No: All -0016 Type: ALARM PERMIT
Parcel No: 2103 -142- 0303 -4
Site Address: 2672 CORTINA LN VAIL
Location:
Total Fees: $456.75
This Payment: $456.75 Total ALL Pmts: $456.75
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
BP 00100003111100 FIRE ALARM PERMIT FEES 168.75
PF 00100003112300 PLAN CHECK FEES 288.00
Department of Community Development
75 South Frontage Road
Vail, Colorado 81657
Tel: 970 - 479 -2128
Fax: 970 - 479 - 2452
Web: www.vailgov.c
D D evelo pmen a e dn '
FIRE ALARM PERMIT
Commercial and Residential Fire Alarm shop drawings are required at the time of application
submittal and must included information listed on the 2nd page of this form. Application will
not be accepted without this information.
Project Street Address:
2672 CORTINA WAY
(Number) (Street)
Building /Complex Name:
Contractor Information:
Company: Thul Electronics
Company Address: PO Box 534
City: Avon State: CO
Contact Name: Ron Davidson
Contact Phone: (970) 949 -4638
E -Mail ron @thulelectronics.com
(Suite #)
Office Use:
Project #: PiRs 1 I — 00(0
Building Permit #: 6 11 –
Alarm Permit #: A I l – C) C) 1 U
Lot #: Block # Subdivision:
Detailed Description of Work: FIRE ALARM UPGRADE
Zip: 81620 FOR REMODELED SINGLE FAMILY HOME.
SEE PLANS FOR DETAILED SCOPE OF WORK.
(use additional sheet if necessary)
Town of Vail Contractor Registration No.:
112 -S Does a Fire Alarm Exist? Yes ( +) No( )
Dlgi[allys,gnedbyDeborahShane[ Does a Sprinkler System Exist? Yes ( +) No( )
Deborah Shaner oNcn= DeborahS ,1, o =6han. Safety,
X u =FPE ,email =shaneds @comcascnet. US
Date: 2011.04.20 13 41:16 - 06'00'
Work Class:
Contractor Signature (required)
New ( ) Addition ( )Remodel ( +) Repair ( )
Property Information Retro -Fit ( ) Other ( )
Parcel #: 2103- 142 -03 -034
(For parcel #, contact Eagle County Assessors Office at 970- 328 -8640 or Type of Building:
visit www.eaglecounty.us /patie) Single - Family (+) Duplex ( ) Multi - Family ( )
Tenant Name: Commercial ( ) Restaurant ( ) Other ( )
Owner Name: POCKROSS, KEITH M. & MIRIAM R
Date Received:
Complete Valuation for Fire Alarm Permit:
Fire Alarm $: $4500 ffTl -' ME-5
WK 4u lull
OWN OF-VA-1
29- May -09
P R O D U C T I N F O R M A T I O N B U L L E T I N
V'A
• Intelligent, self- diagnostics
• On -site maintenance alert
• Field replaceable optical chamber
• Low - profile design
• Plug -in terminal block
• Advanced false alarm immunity
4491448 SERIES
Self - Diagnostic, Four.
Wire, Photoelectric
Smoke Detectors
Model numbers:
449AT, 449C, 449CT, 449CRT, 449CST, 449CSTE,
449CSRT, 449CSRH, 449CTE
®L FM ULC
LISTED APPIKWW
California State Fire Marshal Approved
MEA (New York City) Approved
ULC model numbers:
448AT, 448C, 448CT, 448CST, 448CSRH, 448CTE
The ESL 449/448 Series self- diagnostic, four -wire
smoke detectors continually monitor their own
sensitivity and operational status, and provide a
visual trouble indication if they drift out of sensitivity
range or fail internal diagnostics. This unique,
patented technology meets NFPA 72 field sensitivity
testing requirements without the need for external
meters.
Additional diagnostic information is activated by
applying a magnet near the detector's integral reed
switch. This initiates a self- diagnostic routine and
provides visual indication of sensitivity level, or if
service is required.
This series is easily cleaned by simply replacing
ESL's proprietary field- replaceable optical chamber. All
models are designed to reduce false alarms from
dust, insects, RFI, and external light.
An integral combination rate -of -rise and fixed
135 °F (57 °C), 50 -foot rated, heat sensor is available
with all "T" model detectors (see selection guide),
allowing latching of the alarm for either smoke or
heat. The 449CSRH includes an isolated alarm
output for heat and activates an internal non - latching
sounder (local alarm) for smoke, making it ideal for
motel /hotel and dormitory rooms where smoking is
permitted.
continued
ESL 449 Series Smoke Detectors
Architectural and Engineering Specifications
The ESL 449 Series low - profile, self- diagnostic, four -wire
smoke detectors work on the light scattering principle. A
pulsed infrared light- emitting diode serves as the light source,
and a high -speed photodiode as the sensing element. When
the amount of light reflected onto the photodiode reaches the
sensitivity setting, the smoke sampling rate increases. Three
(3) successive smoke sensings above the sensitivity setting
are required to sound an alarm. This design has superior
protection against false alarms caused by dust, insects, RF
and ambient - light.
A confirmed alarm causes the normally flashing power
indicator LED to light continuously and the alarm relay to
operate. A trouble indication is automatically displayed by
flashing the LED every second. This meets NFPA 72 field
sensitivity testing requirements. An internal 85 dB horn
(available in "S" models) emits a temporal 3 when the
detector alarms and a steady tone when power polarity is
reversed.
Product Data
Feature
Sensitivity .................. ...............................
3.1 - 1.0 % /ft. (max.)
Isolated Fixed Temp.
3.1 + 0.50 % /ft. (min)
Operating temp. range ...............
32 °F to 120 °F (0 °C to 50 °C)
Operating humidity range ..... ...............................
0 to 95% RH
Minimum voltage - C, CT, CRT, CST, CSRT, CSRH ,
CSTE..........................................
............................... 8.5V
- AT ...............................................
............................... 5.1V
Maximum voltage - C, CT, CRT,
CST, CSRT, CSRH,
CSTE............................................
............................... 33V
AT.................................................
............................... 27V
Maximum ripple (peak to peak) .........
............................... 10%
Typical average standby current
.......... ...........................70µA
- CSTE .........................................
............................... 23mA
Typical alarm current - C, CT and AT ............................ 15mA
- CRT ...............................................
...........................31mA
Selection Guide
The proprietary optical sensing chamber is field replaceable,
allowing quick and easy cleaning and maintenance.
Models with auxiliary relays are approved for releasing
service.
This low profile product is equipped with a hinged cover, a
concealed tamper- resistant latch, and insect screens.
Wiring terminates in plug -in, clamp -type screw terminals.
Detectors mount to a standard single -gang electrical box, a
four -inch octagonal, four -inch square electrical box, or
WIREMOLD 5739 fixture box.
Smoke Detector Spacing
On smooth ceilings (as defined in NFPA 72), spacing of 30 feet
(9.1 meters) may be used as a guide. Other spacing may be used
depending on ceiling height, high air movement, and other
conditions or response requirements.
185'(4170
0
- CST ........................................... ............................... 40mA
-CSRT, CSRH, CSTE ................. ............................... 51 mA
Typical avg. polarity reverse current
- CST, CSRT, CSTE, and CSRH ..... ...........................10mA
Sounder specifications .......... ............................... 85 dB at 10'
Heat detector specifications
fixed temperature ...... ............................... 135 °F (57.2 °C)
rate of rise .... 15 °F /min. & >105 °F (8.3 °C /min. & >40.6 °C)
Auxiliary relay contacts 2A @ 28 VDC or 120 VAC (resistive)
Alarm contacts ........................ 500 mA @ 36 VDC (resistive)
Field wiring size ................... ............................... 14 - 24 AWG
Packaging ....................... 10 detectors are packed in a carton
Color .......................... ..........................white cover /white base
with UV inhibitor to prevent yellowing
Listing .............................. UL 268, ULC FM, CSFM and MEA
Designator
Feature
Description
H
Isolated Fixed Temp.
Isolated fixed 135 °F (57 °C) and rate of rise heat detector, independently trips the LED and
alarm and Rate of Rise
output. Smoke detector activates internal sounder (local alarm) and auxiliary relay, but
Heat Detector
does not latch. Approved as both single station smoke alarm and system heat detector.
Ideal for hotel, motel and dormitory rooms where smoking is allowed.
R
Auxiliary Relay
Used to activate other devices such as elevator recall, door holders, strobes, etc. Listed for
releasing service.
S
Built -in Sounder
85dB built -in sounder alarms when smoke is detected or when power wiring polarity is
reversed.
T
Intergrated Fixed
Intergrated Fixed 135 °F (57 °C) temperature and rate of rise heat detector.
Temp. and Rate of
Either heat detector or smoke detector can trip and latch LED and alarm protection.
Rise Heat Detector
relay outputs.
E
Built -in end of line
Relay is normally energized and will trip with loss of power. Can also provide notification
power supervision relay
when detector needs maintenance.
i n t e r l o g i ►,'i•. PH 503.692.4052
USA & Canada: 800.547.2556
Technical Service: 800.648.7424 Fax Back: 800.483.2495
wwwsentrol.com www.inteflogixsecufity.com
E -3965 Rev B -1101
92001 Inwbgm Inc.
Intarlogm Caddz, ESL, ITI and Smtrol are trademarks of
krterlogmlm.
SYSTEM
SENSOR`
5600 Series Mechanical
Heat Detectors
System Sensor's 5600 series mechanical heat detectors
offer a low -cost means for property protection against
fire, and for non -life- safety installations where smoke
detectors are inappropriate.
Features
• Multiple configurations for installations:
- Single- and dual- circuit models
- Fixed temp and combination fixed- temp /rate -of -rise
1357 or 194 °F ratings.
• Plain housing for residential installations (Model 5601 P)
• Easy -to -use terminal screws
A broad range of back box mounting options:
- Single gang
- 3.5 "and 4- Octagonal
-4- square with square to round plaster ring
• Reversible mounting bracket
Agency Listings
& <F M > MEA
LISTED APPROVED approved 0
S'!ic° ,otens my:,t i. 7270- 1101:221
ri
Multiple configurations. The 5600 series offers a full -line of
configurations to accommodate a broad range of applications. Both
single- and dual- circuit models are available for low- and high -
temperature ratings with either fixed temperature or combination
fixed temperature /rate -of -rise (ROR) activation. The ROR element of
the fixed /ROR models is restorable to accommodate field- testing.
Installation flexibility. To satisfy a variety of installation needs,
the 5600 series easily mounts to single -gang and octagonal back
boxes. And these models accommodate four - square back boxes,
when used with a square to round plaster ring. The reversible
mounting bracket permits both Flush- and surface -mount back box
installations.
Visual identification. The 5600 series provides clear markings on
the exterior of the unit to ensure that the proper detector is being
used. Alphanumeric characters identify the activation method, as
well as the temperature rating, in Fahrenheit and Celsius degrees.
Fixed temperature models are identified FX, while combination
fixed /rate -of -rise units are marked FX /ROR.The 5600 series also
provides a post - activation indicator in the form of a collector. When
the detector is activated, the collector drops from the unit, making it
easy to identify the unit in alarm.
ifications
Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire
Protective Signaling Systems. The detector shall be either a single- circuit or a dual - circuit type, normally open. The detector shall be rated for activation at either
135 °F (57'C) or 194 °F (90 °C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature /rate -of -rise thermal sensor.
The rate -of -rise element shall be activated by a rapid rise in temperature, approximately 15 °F (8.3 °q per minute. The detector shall include a reversible mounting
bracket for mounting to 31/2 -inch and 4 -inch octagonal, single gang, and 4 -inch square back boxes with a square to round plaster ring. Wiring connections shall
be made by means of SEMS screws that shall accommodate 14 -22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing
to identify its temperature rating and activation method. The rate -of -rise element of combination fixed temperature /rate -of -rise models shall be restorable, to
allow for field- testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm.
Physical/Operating
Maximum Installation Temperature 5601 P, 5603,562 1, and 5623: 100 °F (38 °C)
5602, 5604, 5622, and 5624:150'F (65.6 °C)
Operating Humidity Range 5 to 95% RH non - condensing
Dimensions with mounting bracket Diameter: 4.57 inches (I 1.6cm)
Height: 1.69 inches (4.3cm)
Alarm Temperature 56011? 5603, 5621, and 5623: 135 °F (57 °C)
5602, 5604, 5622, and 5624: 194oF (90 °C)
Weight 6 oz. (170 grams)
Rate -of -Rise Threshold 15 °F (83 °C) rise per minute (models 5601 P, 5602, 5621, and 5622 only)
Mounting 3'h -inch octagonal back box
4 -inch octagonal back box
Single gang back box
4 -inch square back box with a square to round plaster ring
Electrical Specifications
Operating Voltage /Contact Ratings 6- 125VAC / 3A
6 -28VDC / 1 A
125VDC / 03A
250VDC / O.1 A
Input Terminals 14 -22 AWG
u
\l
5601P 5602,5622 5603,5623 5604,5624 5621
Orderina Information
5601 P
Single
None
135 °F (57 °C)
Fixed Temperature/ Rate -of -Rise
50 feet x 50 feet (15.24m x 15.2m)
5602
Single
Lettering
194 °F (90 °C)
Fixed Temperature / Rate -of -Rise
50 feet x 50 feet (15.24m x 15.2m)
5603
Single
Lettering
135 °F (57 °C)
Fixed Temperature
25 feet x 25 feet (7.62m x 7.62m)
5604
Single
Lettering
194 °F (90 °C)
Fixed Temperature
25 feet x 25 feet (7.62m x 7.62m)
5621
Dual
Lettering
135 °F (57 °Q
Fixed Temperature / Rate -of -Rise
50 feet x 50 feet (15.24m x 15.2m)
5622
Dual
Lettering
194 °F (90 °C)
Fixed Temperature/ Rate -of -Rise
50 feet x 50 feet (15.24m x 15.2m)
5623
Dual
Lettering
135 °F (57 °C)
Fixed Temperature
25 feet x 25 feet (7.62m x 7.62m)
5624
"NOTE: Refer
Dual
to NFPA72
Lettering
guidelines for spacing
194 °F (90 °C) Fixed Temperature
reductions when ceiling heights exceed 10 feet.
25 feet x 25 feet (7.62m x 7.62m)
SYSTEM 111 6 SY.— 5e�5oi.
3825 Ohio Avenue • St. Charles, IL 60174 Prod— spwfiu10 ssuq«Irochage, mo,noo \Asicsyv mum «comfo,
�y SENSOR Phone: 800- SENSOR2 • Fax: 630-377-6495 cuff— Vc'°"'"fi tio"- 'o`'ud'"9'n„re " "� nndit,ci ` h t
A05- 0351 - 002. 11/06•.1676
Installation Instructions
4193SN Serialized Interface Module (SIM)
The 4193SN is a serialized two -zone expander used to connect alarm sensing
devices to controls which support serial number polling loop devices (i.e., Vista -
40, Vista -50P, and Vista -100).
The 4193SN can be configured as one supervised zone (10K EOLR) and one
unsupervised zone, or two unsupervised zones (normally closed devices only).
Consult the control panel installation instructions for programming information.
Electrical Specification:
Voltage: 7 -11VDC (as supplied from the Ademco control panel for
multiplex polling loop)
Current: 1.5mA
RED ( +)
WHITE (LOOP 1) SUPERVISED EOLR 10K
YELLOW (LOOP 1) UNSUPERVISED
POLLING
LOOP GREEN (LOOP 2) UNSUPERVISED
BLACK ( -) I I BLACK (COMMON)
Wiring Diagram VL
e
LISTED
5789
For Fire Applications:
The 4193SN must be mounted inside the control panel cabinet or inside a UL-
Listed junction box. Loop 1 must be used in the supervised configuration for
Fire. Loop 2 may be used for Burglary.
For UL Burglary Applications:
If using an unsupervised zone of the 4193SN, the unit must be mounted within 3
feet of the alarm initiating device, with no intervening barriers.
ADEMCO
4193SN Serialized Interface Module (SIM)
• For connecting alarm sensing devices and switches to
Ademco multiplex polling loop
Quantity: 1 ea.
Requires control panel with SERIAL NUMBER device capability
(e.g. Vista -40, etc.)
Consult control panel instructions for compatibility
(C L
v LISTED
S789
N7644V2 Rev. B 11/96
5192S D/5192S DT
V -PLEV SMOKE DETECTOR
The Honeywell 5192 Series low profile, addressable V -Plex
smoke detectors deliver state -of- the -art features and
benefits in a cost - effective package. These detectors are
designed to provide open area coverage and are
compatible with Honeywell's VISTA controls supporting
V -Plex technology.
An LED on the detector will blink periodically during normal
conditions, remain on steady during alarm and cease to
pulse if the chamber is out of acceptable sensitivity range.
An extremely powerful feature available within the 5192
Series is the Automatic Maintenance Alert/Reporting
capability — a feature normally found in today's high end
analog addressable systems. The detectors continually
monitor their own sensitivity levels in addition to the basic
normal and alarm conditions. These HIGH and LOW
SENSITIVITY signals are communicated back to the
FEATURES
• Low profile design
• V -Plex addressable loop device
• Automatic maintenance reporting
APPLICATIONS
Honeywell
control, via the V -Plex addressable loop, to indicate locally
and at the central station that the detector may not be able
to detect smoke or may false alarm. This feature works
with VISTA -32171B, 12813P, 128FBP, 2506P, 250FBP, 40,
50P, 100 -24 and FAP FA1600C, FA1660C and FA1700C.
More important is the cost saving associated with
Automatic Maintenance Reporting. The feature is an
approved alternate to NFPA 72 field sensitivity calibration
testing that require external test meters. This eliminates the
need to schedule inspections to determine detector
sensitivity /viability. Another important benefit of these V -Plex
(addressable) smoke detectors is their ability to operate on
existing wiring.
There is no need to run special twisted pair, data grade or
shielded wires, providing you with the right choice for all
your retrofit applications. That equates to cost savings in
time and materials!
• Available with integral heat sensor
• Simple 2 wire installation
• DIP switch or serial number
programmable
• Lines on existing or
conventional wiring
The 5192 Series smoke detectors are designed to provide open area coverage and are well suited for most fire detection
applications. These smoke detectors are compatible with all Honeywell VISTA Fire and Burglary controls that support V -Plex
addressable loop technology. These agency listed alarm initiating devices support most commercial and residential applications. They are
suited for use in museums, hospitals, day care centers, retail stores, strip malls, schools, libraries, fast food chains, medical or
professional office suites and in factory and warehouse environments.
5192SD/5192SDT
V- PLEXTM SMOKE DETECTOR
SPECIFICATIONS
Installation
The 5192 Series smoke detectors are
supplied with a convenient mounting
bracket that allows the detector to
be mounted to a variety of electrical
junction boxes. A removable terminal
block, that accepts 14 to 22 gauge wire
to provide easy wiring connections. The
detectors are designed to meet
all applicable requirements for UL
Commercial and Residential Fire
installations as well as NFPA 72
requirements when installed in
compliance with the National
Electric Code and approved/listed control
panels.
W�
oza-
Fa
J
U
J Q
J
ZZ
=Z
-
O
UJ
�
DIP
m
F Q
SWITCH REMOVABLE
U d
TERMINAL BLOCK
>0
U
U
Wiring
diagram for 5192SD /SDT smoke detector
Compatibility
These smoke detectors are compatible
with all VISTA control panels that support
V -Plex (addressable) polling
loop technology. The detectors support
DIP switch or serial number addressing.
DIP switch configuration are compatible
with 5140XM, VISTA -40, and
VISTA -50P controls.
ORDERING
Serial number addressing is supported on
VISTA -32FB, 1286P, 128FBP, 25013P,
250FBP, 100 -24 and FAP FA1600C,
FA1660C and FA1700C controls. (Refer to
control panel and smoke detector
installation instructions for details.)
Automatic Maintenance
Reporting Compatibility
The automatic maintenance feature is
compatible with the following control
panels:
— VISTA -32FB
— VISTA -128BP
— VISTA- 128FBP
— VISTA -250BP
— VISTA- 250FBP
— FA1600C
— FA1660C
— FA1700C
The automatic maintenance may be
disabled for all other controls that
do not support this feature. Refer
to control panel and smoke detector
Installation Instructions for details.
Electrical:
• System voltage range: 7 -14 V
Standby current (maximum @ 12V):
— LED off: 1.2mA
— LED on: 2.8mA
Mechanical:
• Diameter: 5.5 inches (140mm) (including
mounting bracket)
• Height: 1.7 inches (43mm)
(including mounting bracket)
• Weight: 5.3 ounces (150 grams)
Environmental:
• Installation temperature range:
32° to 100 °F (0° to 38 °C)
• Installation humidity range:
10% to 93% RH, non - condensing
• Heat sensor (5192SDT only):
135 °F fixed temperature
electronic thermistor
• EMI: Meets or exceeds the
following requirements:
— FCC Part 15, Class B Device
— IEC EMC Directive
Agency Listings
• UL268 Commercial System
Smoke Detector
• Meets UL 217 Requirements
for Residential
5192SD Addressable Photoelectric Smoke Detector
5192SDT Addressable Photoelectric Smoke Detector with Integral Heat Sensor
For more information: www.honeywell.com /security/hsc
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
Melville, NY 11747
1.800.467.5875 U5192/D
May 2009
www.honeywell.com
m 2009 Honeywell International Inc.
Honeywell
5808W3
PHOTOELECTRIC SMOKE /HEAT
DETECTOR WITH BUILT -IN
WIRELESS TRANSMITTER
Honeywell
Honeywell's 5808W3 is a 3V lithium powered,
Since there are no holes to drill or wires to run, you can
photoelectronic smoke /heat detector with a built -in
preserve the beauty of the building while protecting it. The
wireless transmitter. It is intended for use with any
5808W3 is an ideal smoke detector for those difficult to wire
5800 Series Wireless Receiver/Transceiver for residential
locations, applications where room aesthetics are critical, or
installations (for commercial installations, the 5881 ENHC
where hazardous materials exist.
or the 5883H receiver is required).
The transmitter can send alarm, tamper, maintenance (when
control panels are equipped to process maintenance signals)
and battery condition messages to the system's receiver.
Smoothing algorithms minimize nuisance alarms by
smoothing out short term spikes from dust and smoke —
virtually eliminating nuisance alarms.
FEATURES
• Improved Robust RF Field
Strength
The distance between the detector
and receiver has been significantly
increased without the need for a
repeater
• Smoothing Algorithms
Mathematical calculations in the
detector's software that minimize
nuisance alarms by smoothing out
short term spikes from dust and
smoke
• Smart Check
A signal is sent to the control panel
when the detector requires cleaning.
This allows a regular, non - emergency
service call to clean the detector
before it goes into alarm.
All models also feature a restorable, built -in, fixed temperature
(135 °F) thermal detector that is also capable of sensing a
pre- freeze condition if the temperature is below 41'F
• Drift Compensation
Virtually eliminates nuisance alarms
from long -term dust build -up by
automatically adjusting the detector's
sensitivity
• Removable Detector Cover and
Chamber Top
The technician is able to quickly and
easily clean the detector chamber
without disassembling the detector
head
• Approved UL Listings for Residential
and Commercial Applications
Both residential and commercial
installation requirements are met
• Additional LED Status Indicators
Identifying between alarm or trouble
conditions is a snap with green and
red LED status indicators. A green LED
denotes a normal condition while the
red LED indicates abnormal conditions.
• Easy -to- install Mounting Base
The sturdy mounting base allows the
detector to be more easily installed
on uneven surfaces (i.e. stucco). The
mounting base has larger mounting
ports, which accommodate drywall
anchors for easy surface mounting.
ADDITIONAL FEATURES:
• Utilizes one long -life 3V lithium
battery
• Microcontroller runs on a 4.0 MHz
clock
• Horn operates at 3.3 KHz with sound
pressure level of 85 dBA at 10 feet
• Built -in wireless transmitter, temporal
code 3 sounder
• Maintenance signal fully complies
with the sensitivity test requirement
specified in NFPA 72, 7 -2.2 and is
approved by UL
5808W3
PHOTOELECTRIC SMOKE /HEAT DETECTOR WITH BUILT -IN WIRELESS TRANSMITTER
SPECIFICATIONS
• Dimensions
- Diameter: 5.3 "', Height: 2.30"
• Weight
- 8.5 ounces (without batteries)
• Operating Temperature
- 32 -100° F (0 -37.8° C)
• Humidity Range
- 0% to 95% RH, non - condensing
• Air Velocity
- 1,000 ft. /min. max.
• Operating Voltage
- 2.5- 3.6VDC
• Standby Current
- 8.5 mA avg.
• Alarm Current
- 35 mA max.
' With adapter bracket (4.9" without mounting base)
tReplacement batteries include Duracell D1_123A, Sanyo CR123A, Panasonic CR123A, or ADEMCO 466
ACCESSORIES (sold separately)
SENS -RDR Infrared
Sensitivity Reader
Reduce testing time with the
handheld SENS -RDR infrared
sensitivity reader. The reader
simplifies sensitivity measurements
and displays them precisely in
terms of percent per foot
obscuration. The SENS -RDR
eliminates the need for magnets,
voltmeters and ladders.
• Power Source
- One 3V CR123A lithium Batteryt
• Audible Output
- 85 dB min. at 10 ft.
• Fixed Temperature Heat Sensor
- 135° F Fixed
• Agency Listings
- UL268 - Commercial and
Residential
RT Removal Tool
Simplifies the attachment
and removal of the
detector head to the
mounting base; it may
be attached to a threaded
extension pole or broom
handle thereby eliminating
the need for ladders.
ORDERING
5808W3 Photoelectric Smoke /Heat Detector with Built -in Wireless Transmitter
Accessories sold separately:
SENS -RDR Hand -held Sensitivity Reader
RT i3 Removal Tool used for easy installation and removal of head from base
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
www.honeywell.com
U5808W3DS /D
September 2008
0 2008 Honeywell International Inc.
Honeywell
5809
WIRELESS HEAT DETECTOR
Honeywell's 5809 wireless fixed heat and rate -of -rise
temperature sensor offers expanded fire detection and
installation flexibility. It is ideal for hard to wire locations and
applications that require more than smoke detection. With no
wires to run, the 5809 is fast and easy to install.
The 5809 combines both rate -of -rise and fixed temperature
sensors. Fires typically cause a rapid rise in temperature in the
FEATURES
• Contains a built -in transmitter which
can send alarm, supervisory and
battery condition messages to the
system's receiver /control unit
• Powered by a three -volt lithium
Honeywell
surrounding area. The 5809's rate -of -rise thermostat senses
the rise in temperature and signals an alarm if the increase is
15° or more per minute. A built -in fixed temperature sensor
will also signal an alarm if the environmental temperature rises
above 135 °F. The 5809 is UL Listed (UL521) and CSFM
approved for commercial and residential applications.
battery. If the battery voltage gets too
low, the 5809 sends a low battery
signal to the control panel
• Features a tamper switch, which
causes a trouble signal to be sent to
the control if the unit is removed from
the mounting base
• UL Listed for Commercial (when using
5881 EH Receiver) or Residential
applications
.M .........
K
surrounding area. The 5809's rate -of -rise thermostat senses
the rise in temperature and signals an alarm if the increase is
15° or more per minute. A built -in fixed temperature sensor
will also signal an alarm if the environmental temperature rises
above 135 °F. The 5809 is UL Listed (UL521) and CSFM
approved for commercial and residential applications.
battery. If the battery voltage gets too
low, the 5809 sends a low battery
signal to the control panel
• Features a tamper switch, which
causes a trouble signal to be sent to
the control if the unit is removed from
the mounting base
• UL Listed for Commercial (when using
5881 EH Receiver) or Residential
applications
5809
WIRELESS HEAT DETECTOR
SPECIFICATIONS:
• Power:
- 3V lithium battery (Duracell DL123A,
Panasonic CR123A, Sanyo CR123A,
Varta CR123A)
- Operating temperature: 40° to
140oF (6° to 60 °C)
- Rate -of -rise temperature: 15 °F (8 °C)
increase per minute (NOTE: Rate -of-
rise sensor does not operate above
38 °C)
Fixed temperature: 135oF (57 °C)
Maximum spacing: 50 ft x 50 ft UL,
30 ft x 30 ft FM (refer to National Fire
Alarm Code Standard NFPA 72 for
application requirements)
- Dimensions: 4.4" diameter /2/2"
deep
• Agency Listings:
- UL 521 Listed for Commercial
(when using 5881 EH Receiver) or
MOUNTING THE DETECTOR:
- You can mount the 5809 on a wall or
ceiling within the protection area:
- Wall mounting: Mount the detector
4" 6" from the ceiling
Ceiling mounting: Mount the detector
at least 4" from any wall. Make sure
the normal ceiling temperature will not
exceed 100 °F (37.8° C).
TESTING THE DETECTOR:
The test procedure should be performed
to determine a good RF transmission
path and again after installation is
completed.
CAUTION: The fixed temperature sensor
is intended for one -time use. Prolonged
heat during testing can damage the unit.
If used carefully following the instructions
described below, the heat from a portable
hair dryer can be used to test the unit. If
the round disk on top of the detector
detaches, the detector must be replaced.
- Activiate the control panel's test mode
ORDERING
5809 Heat Detector
- Refer to NFPA Standard 72 for
detector spacing and other
requirements. Maximum spacing for
UL installations is 50' x 50'
- Avoid mounting the detector near
heat generating devices (e.g. ovens,
heat vents, furnaces, boilers)
IMPORTANT: Heat detectors should
Residential applications
• Wireless Transmission Path Test:
- A good RF transmission path must
be established from the proposed
mounting location before permanently
installing the detector. To determine
that there is a good signal reception
from the proposed location, perform
the test procedure described in the
installation instructions procedure.
be used for property protection.
Reliance should not be placed soley
on heat detectors for life safety.
When life safety is involved, smoke
detectors MUST also be used.
Detectors must not be painted.
- Use either method (a) or (b) or activate - Exit the control's test mode
the detector FCC ID: CFS 8DL 5809
(a) Press and release the activation
button on the PC board assembly OR
(b) Holding a portable hair dryer about
12 to 18 inches away from the detector,
turn the dryer on and aim the warm air
at the side of the detector.
CAUTION: Aiming the dryer directly at
the round disk on the detector can
damage the unit to be replaced.
- The system's keypad should beep and
the detector's ID should be displayed
Honeywell Security & Custom Electronics
Honeywell
2 Corporate Center Drive Suite 100
P.O. 9040
Melville, NY 11747
www.honeywell.com
This device complies with part 15 of
FCC rules.
Operation is subject to the following
conditions:
(1) This device may not cause harmful
interference, and (2) this device must
accept any interference received,
including interference that may cause
undesired operation.
U58MD
October 2007
® 2007 Honeywell International Inc.
Honeywell
* ** *DISARMED * * **
READY TO ARM
6160 --
ALPHA DISPLAY KEYPAD
WITH DOOR ATTACHED
The 6160 Deluxe Keypad is easy to install and simple to
use. The attractive white console blends with any decor and
features a contoured, removable door that conceals
illuminated soft -touch keys. The 6160 also features a new
larger and brighter 32- character display with easy -to -read
plain - English status messages.
FEATURES
• Large, easy -to -use keypad
• Keys continuously backlit for greater
visibility
• Speaker with audible beeps
to indicate:
System status
Entry/exit delay
Other alarm situations
SPECIFICATIONS
Physical
• 5- 5/16 "H x 7 -3/8 "W x 1- 3/16 "D
(135mm x 190mm x 30mm)
Current
• Standby -40mA
• Activated Transmission- 1 60mA
IS ARMED:+::+::+:*
READY TO ARM
r 0 0
- WITHOUT DOOR
The oversized function keys are easily accessed even when
the keypad door is closed, and can be programmed for fire,
burglary, personal emergencies and other operations. Colored
self- adhesive labels are included.
• Zones and system events displayed
in plain English
• No confusing blinking lights
• Four programmable function keys
Wiring
• - (Black): Ground
• + (Red): +12 VDC (Aux. Power)
• D1 (Green): "Data in" to control panel
• DO (Yellow): "Data out' from
control panel
ORDERING
6160 Alpha Display Keypad
Honeywell Security & Custom Electronics
Honeywell International Inc.
PO Box 9035
Syosset, NY 11791
www.honeywell.com
C006010
v6t60iD
September 2006
0 2006 Honeywell International Inc.
• System functions clearly labeled
• Functions performed by just entering
security code plus command
• White with removable door blends
with any decor
Compatibility
• Fully compatible with all
VISTA controls.
Honeywell
�� SYSTEM
�A SENSOR'
Selectable- Output
Horns, Strobes, and
Horn Strobes
SpectrAlert* Advance selectable - output horns, strobes,
and horn strobes are rich with features guaranteed to
cut installation times and maximize profits.
Features
• Plug -in design with minimal intrusion into the back box
•Tamper- resistant construction
Automatic selection of 12- or 24 -volt operation at 15 and 15/75
candela
Field- selectable candela settings on wall and ceiling units: 15, 15/75,
30, 75, 95, 110, 115, 135, 150, 177, and 185
Horn rated at 88+ dBA at 16 volts
Rotary switch for horn tone and three volume selections
Universal mounting plate for wall and ceiling units
Mounting plate shorting spring checks wiring continuity before
device installation
Electrically compatible with existing SpectrAlert products
Compatible with MDL sync module
Agency Listings
SIGNALING
UL
F M
LISTED
X5512 (strobes:
APPROVED
r e m S s t e m S a n s o r
kJ
The SpectrAlert Advance series offers the most versatile and
easy -to -use line of horns, strobes, and horn strobes in the industry.
With white and red plastic housings, wall and ceiling mounting
options, and plain and FIRE - printed devices, SpectrAlert Advance can
meet virtually any application requirement.
Like the entire SpectrAlert Advance product line, horns, strobes,
and horn strobes include a variety of features that increase their
application versatility while simplifying installation. All devices
feature plug -in designs with minimal intrusion into the back
box, which make installations fast and foolproof while virtually
eliminating costly and time - consuming ground faults. Furthermore,
a universal mounting plate with an onboard shorting spring tests
wiring continuity before the device is installed, protecting devices
from damage.
In addition, field - selectable candela settings, automatic selection
of 12- or 24 -volt operation, and a rotary switch for horn tones with
three volume selections enables installers to easily adapt devices to
suit a wide range of application requirements.
MEA
approved
7125- 1653186(iodoor strobes)
7125- 16S318S (hom strobes,
MEA452 -05 -E
chime strobes)
7135- 16S3.189 (horns, chimes)
r e m S s t e m S a n s o r
kJ
The SpectrAlert Advance series offers the most versatile and
easy -to -use line of horns, strobes, and horn strobes in the industry.
With white and red plastic housings, wall and ceiling mounting
options, and plain and FIRE - printed devices, SpectrAlert Advance can
meet virtually any application requirement.
Like the entire SpectrAlert Advance product line, horns, strobes,
and horn strobes include a variety of features that increase their
application versatility while simplifying installation. All devices
feature plug -in designs with minimal intrusion into the back
box, which make installations fast and foolproof while virtually
eliminating costly and time - consuming ground faults. Furthermore,
a universal mounting plate with an onboard shorting spring tests
wiring continuity before the device is installed, protecting devices
from damage.
In addition, field - selectable candela settings, automatic selection
of 12- or 24 -volt operation, and a rotary switch for horn tones with
three volume selections enables installers to easily adapt devices to
suit a wide range of application requirements.
SpectrAlert Advance Specifications
General
SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 1'/rinch back box, 4 -inch octagon back box, or double -gang back
box Two -wire products shall also mount to a single -gang 2 x 4 x 17 /s -inch back box A universal mounting plate shall be used for mounting ceiling and
wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with
the Sync -Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.
When used with the Sync-Circuit Module, 12- volt -rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24 -volt -rated notification
appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit
from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field - selectable candela settings including 15,15/75, 30
75,95, 1 I Q 115,135,150,177, and 185.
Strobe
The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be
wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at
1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system.
Horn Strobe Combination
The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The
horn strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling
appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector
system. The horn shall have three audibility options and an option to switch between a temporal three - pattern and a non - temporal (continuous) pattern. These
options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models
shall operate on a coded or non -coded power supply.
Synchronization Module
The module shall be a System Sensor Sync -Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize
SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a
single pair of wires. The module shall mount to a PA6 x 411,6 x 2' /8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z
(class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they
control. The module shall not operate on a coded power supply.
Physkal/Electrical Specifications
Standard Operating Temperature 32 °F to 120 °F (0°C to 49 °C)
Humidity Range 10 to 93% non - condensing
Strobe Flash Rate 1 flash per second
Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1
Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal)
Input Terminal Wire Gauge 12 to 18 AWG
Ceiling -Mount Dimensions (including lens) 6.8- diameter x 2.5 -high (173 mm diameter x 64 mm high)
Wall -Mount Dimensions (including lens) 5.6 -L x 4.7 -W x 2.5- D (142 mm L x 119 mm W x 64 mm D)
Horn Dimensions 5.6 -L x 4.7 -W x 1.3 -D (142 mm L x 119 mm W x 33 mm D)
Wall -Mount Back Box Skirt Dimensions (BBS -2, BBSW -2) 5.9 -L x 5.0 -W x 2.2 -D (151 mm L x 128 mm W x 56 mm D)
Ceiling -Mount Back Box Skirt Dimensions (BBSC -2, BBSCW -2) 7.1- diameter x 2.2 -high (180 mm diameter x 57 mm high)
Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR -H5, TRW -HS) 5.7 -L x 4.8 -W x 0.35 -D (145 mm L x 122 mm W x 9 mm D)
Ceiling -Mount Trim Ring Dimensions (sold as a 5 pack) (TRC -HS, TRCW -HS) 6.9 "diameter x 0.35" high (175 mm diameter x 9 mm high)
Notes:
1. Full Wave Rectified (FWR) voltage is a non - regulated, time - varying power source that is used on some power supply and panel outputs.
2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd.
P05 -0395-W7
UL Current Draw Data
UIL Max. Strobe Current Draw (rnA RMS)
8 -17.5 Volts 16 -33 Volts
Candela
DC
FWR
DC
Standard 15
123
128
66
Candela Range 15/75
142
148
77
30
NA
NA
94
8 -17.5 Volts 16 -33 Volts
FWR Sound Pattern dB DC FWR DC FWR
71 Temporal High 57 55 69 75
81 Temporal Medium 44 49 58 69
96 Temporal Low 38 44 44 48
75 NA NA 158 153 Non - temporal High 57 56 69 75
95 NA NA 181 176 Non - temporal Medium 42 50 60 69
110 NA NA 202 195 Non - temporal Low 41 44 50 50
115 NA NA 210 205 Coded High 57 55 69 75
High 135
Candela Range 150
177
185
DC Input
NA NA 228 207 Coded Medium 44 51 56 69
NA NA
NA NA
NA NA
Offm
8 -17.5 Volts
246 220 Coded Low 40 46 52 50
281 251
286 258
Standard Candela Range (11 S-1 I S cd)
16 -33 Volts
15 15/75 15 15/75 30 75 95 110 115
Temporal High 137 147 79 90 107 176 194 212 218
Temporal Medium
132
144
69
80
97
157
182
201
210
Temporal Low
132
143
66
77
93
154
179
198
207
Non - Temporal High
141
152
91
100
116
176
201
221
229
Non Temporal Medium
133
145
75
85
102
163
187
207
216
Non - Temporal Low
131
144
68
79
96
156
182
201
210
FWR Input
242
259
293
299
Non Temporal Medium
219
232
262
267
Temporal High
136
155
88
97
112
168
190
210
218
Temporal Medium
129
152
78
88
103
160
184
202
206
Temporal Low
129
151
76
86
101
160
184
194
201
Non Temporal High
142
161
103
112
126
181
203
221
229
Non Temporal Medium
134
155
85
95
110
166
189
208
216
Non-Temporal • 80 90 105
UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, High Candela Range (135 -185 cd)
16-33 Volts 16-33 Volts
DC Input
135
150
177
185
FWR Input
135
150
177
185
Temporal High
245
259
290
297
Temporal High
215
231
258
265
Temporal Medium
235
253
288
297
Temporal Medium
209
224
250
258
Temporal Low
232
251
282
292
Temporal Low
207
221
248
256
Non - Temporal High
255
270
303
309
Non Temporal High
233
248
275
281
Non - Temporal Medium
242
259
293
299
Non Temporal Medium
219
232
262
267
Non Temporal Low
238
254
291
295
Non- Temporal Low
214
229
256
262
Horn Tones and Sound Output Data
8 -17.5 16 -33 24-Volt Nominal
Switch Volts Volts Reverberant Anechoic
Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR
1 Temporal High 78 78 84 84 88 88 99 98
2 Temporal Medium 74 74 80 80 86 86 96 96
3 Temporal Low 71 73 76 76 83 80 94 89
4 Non - Temporal High 82 82 88 88 93 92 100 100
5 Non Temporal Medium 78 78 85 85 90 90 98 98
6 Non Temporal
Low
75
75
81
81
88
84
96
92
7r Coded
High
82
82
88
88
93
92
101
101
8r Coded
Medium
78
78
85
85
90
90
97
98
9t Coded
Low
75
75
81
81
88
85
96
92
TSettings 7, 8, and 9 are not available on 2 -wire horn strobe.
A05 -0395 -007
SpectrAlert Advance Dimensions
Di
4 J
Wall-mount horn strobes Ceiling-mount horn strobes
I
7.1' 2.25 -1
5.05 — 2.23:1 Dia.
o
0 QS
59 O O
Wall back box skirt Ceiling back box skirt
SpectrAlert Advance Ordering Information
Wall Horn Strobes
Ceiling Strobes
P2R *t
2 -Wire Horn Strobe, Standard cd *, Red
SCR
Strobe, Standard cd, Red
P2RH*
2 -Wire Horn Strobe, High cd, Red
SCRH
Strobe, High cd, Red
P2W*
2 -Wire Horn Strobe, Standard cd, White
SCW*
Strobe, Standard cd, White
P2WH*
2 -Wire Horn Strobe, High cd, White
SCWH
Strobe, High cd, White
P4R*
4 -Wire Horn Strobe, Standard cd, Red
Horns
P4RH
4 -Wire Horn Strobe, High cd, Red
HR
Horn, Red
P4W
4 -Wire Horn Strobe, Standard cd, White
HW
Horn, White
Wall Strobes
Accessories
SR *t
Strobe, Standard cd, Red
BBS -2
Back Box Skirt, Wall, Red
SRH *t
Strobe, High cd, Red
BBSW -2
Back Box Skirt, Wall, White
SW*
Strobe, Standard cd, White
BBSC -2
Back Box Skirt, Ceiling, Red
SWH*
Strobe, High cd, White
BBSCW -2
Back Box Skirt, Ceiling, White
Ceiling Horn
Strobes
TR -HS
Trim Ring, Wall, Red
PC2R*
2 -Wire Horn Strobe, Standard cd, Red
TRW -HS
Trim Ring, Wall White
PC2RH
2 -Wire Horn Strobe, High cd, Red
TRC -HS
Trim Ring, Ceiling, Red
PC2W*t
2 -Wire Horn Strobe, Standard cd, White
TRCW -HS Trim Ring, Ceiling, White
PC2WH*
2 -Wire Horn Strobe, High cd, White
PC4R
4 -Wire Horn Strobe, Standard cd, Red
PC4RH
4 -Wire Horn Strobe, High cd, Red
PC4W
4 -Wire Horn Strobe, Standard cd, White
Notes:
* Add %P'to model number for plain housing (no •FIRE'marking on cover), e.g., P2R -P.
t Add' -SP'to model number for "FUEGO' marking on cover, e.g., P2R -SP.
*"Standard cd"refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings.
SYSTEM3825 Ohio Avenue • St. Charles, IL 60174 Prod Y7zoo9System sensor
4 SENSOR" masons s—t n,rnd drag he wace � offt s u si—tn to
Phone: 800 SENSOR2 •Fax: 630 - 377 6495 ""tP°a �' "� °°0395- 07-410w#2132 "w"n a'a lee`
A05 -0395-007.4/09•Y1131
0-: SYSTEM
�� SENSOR"
Mini -Horns
The SpectrAlert'Advance series of mini-horn sounders
are designed to simplify installations to provide
primary and secondary signaling for fire and security
applications.
Features
12 and 24V operation
• High and low volume settings
-Temporal and non - temporal tones
• Mounts to single gang back box
• Compatible with MDL sync module
Mechanically and electrically compatible with PA400 series
Mini - Alert- sounders
Agency Listings
& FM MEA`
LISTED APPROVED approved
I.; I i „ .. .._ I L 71351653:196
S s t e S e
The MHR and MHW mini -horns operate at 12 and 24 volts and are
ideal for hotel, motel or residential fire system applications, where
a smaller notification device is desired.The mini -horns offer high
and low volume settings, and temporal or non - temporal tones. The
horns can be mounted to single gang back boxes for aesthetically
sensitive applications. Synchronization is also provided when using
the MDL module.
The MHR and MHW mini -horns can operate between 32 and 120
degrees Fahrenheit from a regulated DC or full -wave rectified,
unfiltered power supply. They are listed to Underwriter's Laboratories
Standard UL 464 for fire protective signaling systems.
trAlert" Advance Mini -Horn Specifications
Mini -horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a single gang back box. Mini -
horn shall he listed to Underwriter's Laboratories Standard U1464 for fire protective signaling systems. Mini -horns shall operate between 32 and 120 degrees
Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. When used with the Sync-Circuit' Module, 12 -volt rated notification appliance
circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts.
Dimensions 4.61 x 2.9W x .45"D
Weight 2.67 oz.
Operating Temperature Range 32 °F to 120 °F (0 °C to 49 °Q
Mounting Surface: single -gang back box
Flush: 4"x 4" BBD deep back box (23/4 "deep)
Input Terminals 12 to 18 AWG
Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR
Operating Voltage 8 -33
Operating Voltage with MDL 9 -33
UL Sound Output and Current Draw Data
Switch Setting Pattern Output Level
8 -17.5 VDC
8 -17.5 VFWR
Nominal 12 VDC
Nominal 12 VFWR
16-33 VDC
16 -33 VFWR
1 Temporal High
68
67
71
70
78
76
2 Temporal Low
66
65
69
68
76
75
3 Non - temporal High
72
71
75
74
80
79
4 Non- temporal Low
Sounder Current Draw
70
69
73
72
78
77
Switch Position Sound Pattern
Volume
8 -17.5 Volts
DC
FWR
16 -33 Volts
DC
FWR
1 Temporal
High
12
10
17
15
2 Temporal
Low
10
9
14
13
3 Non - temporal
High
22
17
29
25
4 Non- temporal
Low
17
13
21
19
Ordering Information
Description Part No.
MHR Mini -Horn, Red
MHW Mini -Horn, White
SYSTEM 021x17 System mA nc,.
3825 Ohio Avenue • St. Charles, IL 60174 croa�a���4ra "s s�gecerocnz "ye,�man��e.�n�tsne�,u "ro�comror
�1 SENSOR Phone: 800- SENSOR2 • Fax: 630-377-6495 " ""`�""s " "' "'° "x"°0414 °W-1/07.917" ""an� dam sn�
A05- 0414 - 000.1/07•/1743
�p �ul/ER����%irfl
Rechargeable Sealed Lead -Acid Battery
Mpp L P5 1MjL) F1
12 YYvH 7ANmV. W.
PS -1270
12 Volt 7.0 Amp. Hrs.
Features:
• Absorbent Glass Mat (AGM) technology for
superior performance.
• Valve regulated, spill proof construction
allows safe operation in any position.
• Power /volume ratio yielding unrivaled
energy density.
• Rugged plastic case and cover
• Approved for transport by air. D.O.T., I.A.T.A.,
F.A.A. and C.A.B. certified.
• U.L. recognized under file number MH 20845.
W
PERFORMANCE SPECIFICATIONS
Nominal Voltage ........................................................................................................................ ............................... 12 volts (6 cells in series)
Nominal Capacity
20 hour rate (350mA to 10.50 volts) .......................................................................................................
............................... 7.0 A.H.
10 hour rate (650mA to 10.50 volts) .......................................................................................................
............................... 6.5 A.H.
5 hour rate (1.2A to 10.20 volts) ...........................................................................................................
............................... 6.0 A.H.
1 hour rate (4.5A to 9.00 volts) ............................................................................................................
............................... 4.5 A.H.
15 min rate (14A to 9.00 volts) ..............................................................................................................
............................... 3.5 A.H.
ApproximateWeight .....................................................................................................................
............................... 5.70 pounds (2.59 k9)
Energy Density (20 hour rate) ............................................................... ...............................
1.43 Watt- hours /cubic inch (87.3 Watt- hours /I)
Specific Energy (20 hour rate) .................................................................. ...............................
14.7 Watt-hours /pound (32.4 Watt-hours /kg)
Internal Resistance (Fully Charged Battery) ....................................................................
............................... 22 milliohms (approximately)
Maximum Discharge Current ( < 7 Min.) .....................................................................................................
............................... 21 amperes
Maximum Short- Duration Discharge Current ( < 10 Sec.) .......................................................................
............................... 70 amperes
Terminal configurations ...................... ..........................Quick disconnect tabs,
"F1 ": 0.187' x 0.032 ", mate with AMP. INC. FASTON "187"
Quick disconnect tabs,
"F2 ": 0.250" x 0.032 ", mate with AMP. INC. FASTON "250"
Shelf Life — % of nominal capacity at 68° F (20° C)
1 Month ..........................................................................................................................................................
............................... 97%
3 Months ........................................................................................................................................................
............................... 91%
6 Months ........................................................................................................................................................
............................... 83%
Operating Temperature Range
Charge....................................................................................................................................
............................... -4 °F ( -20 °C) to 122 °F (50 °C)
e Discharge ...............................................................................................................................
............................... -4 °F ( -20 °C) to 140 °F (60 °C)
Case..................................................................................................................................................................
............................... ABS Plastic
TECHNICAL DATA:
Shelf Life and Storage
100
0
O
80
c
O
60
T
Ei 40
a
U 00 2 4 6 8 10 12 14 16 18 20
Standing Period (Months)
Life Characteristics in Stand -By Use
100
80
A
60
U
0 40
m 20
m
0
120
100
0
Z, 80
U
A
60
U
C
.c 0 40
v
20
0
0
Ambient Temperature 20'C (68'F)
Float Charging Voltage
2.25 - 2.30 V /Cell
0 1 2 3 4
Years
Life Characteristics in Cyclic Use
of
less
C4
fore
sary
,er
A
of
ach
_
SALES & MARKETING IS09001 -2000
CUSTOMERSERVICE
3106 Spring Street
7550 Panasonic Way
Redwood City, CA 94063 USA FM39170
San Diego, CA 92154 USA
Charging is i
Tel: 619-661-2030 Fax: 619-661-3648
national - sales @power- sonic.com www.power- sonic.com
customer- service @power- sonic.com
1G „I I I � 1
14 ,?
necessary ui
Discharge
Depth 50%
Discharge
Depth 30%
1. Discharge Current 0.2C (Final Voltage 1.7V /Cell)
2. Charge Current: 0.1C
3. Ambient Temperature: 20 °C to 25 °C (68 °F to 77 °F)
Final
Voltage
10.5V
:±100%
of cap
is required.
9.60V �\
9.OV
5 °C
Charging br
20%
0%
8.10V
(41-F)-
use is nece
to help rece
full capacit,
harge may
40 °C
(104 °F)
30 °C
(86'F)
20'C
(68 -F)
o res ore full
arteries
et batteries n
flis state.
U 00 2 4 6 8 10 12 14 16 18 20
Standing Period (Months)
Life Characteristics in Stand -By Use
100
80
A
60
U
0 40
m 20
m
0
120
100
0
Z, 80
U
A
60
U
C
.c 0 40
v
20
0
0
Ambient Temperature 20'C (68'F)
Float Charging Voltage
2.25 - 2.30 V /Cell
0 1 2 3 4
Years
Life Characteristics in Cyclic Use
of
less
C4
fore
sary
,er
A
of
ach
200 400 600 800 1000 1200
Number of Cycles
CHARGING
Cycle Applications: Limit initial current to 2.1A. Charge until battery
voltage (undercharge) reaches 14.40 to 14.70 volts at 68 °F (20 0C).
Hold at 14.40 to 14.70 volts until current drops to approximately 70mA.
Battery is fully charged under these conditions, and charger should
either be disconnected or switched to "float" voltage.
"Float" or "Stand -By" Service: Hold battery across constant volt-
age source of 13.50 to 13.80 volts continuously. When held at this
voltage, the battery will seek its own current level and maintain itself
in a fully charged condition.
NOTE: Due to the self- discharge characteristics of this type of bat-
tery, it is imperative that they be charged after 6 -9 months of stor-
age, otherwise permanent loss of capacity might occur as a result of
sulfation.
(v)
14.0
13.0
Q
1 12.0
M
0 11.0
C 10.0
E
H 9.0
8.0
PS -1270
Discharge Characteristics
X111\ Ilk1
■�II��II..�
■�I�a11 ■111 ■1
1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 40
min. X hrs.
Discharge Time
Discharge Time vs. Discharge Current
20
15
10
5
t
2
E
E 1
i=
d
E 30
r
U
N
10
5
_
SALES & MARKETING IS09001 -2000
CUSTOMERSERVICE
3106 Spring Street
7550 Panasonic Way
Redwood City, CA 94063 USA FM39170
San Diego, CA 92154 USA
Tel: 650-364-5001 Fax: 650-366.3662 -
Tel: 619-661-2030 Fax: 619-661-3648
national - sales @power- sonic.com www.power- sonic.com
customer- service @power- sonic.com
1G „I I I � 1
14 ,?
Discharge
Depth 100%
Discharge
Depth 50%
Discharge
Depth 30%
1. Discharge Current 0.2C (Final Voltage 1.7V /Cell)
2. Charge Current: 0.1C
3. Ambient Temperature: 20 °C to 25 °C (68 °F to 77 °F)
200 400 600 800 1000 1200
Number of Cycles
CHARGING
Cycle Applications: Limit initial current to 2.1A. Charge until battery
voltage (undercharge) reaches 14.40 to 14.70 volts at 68 °F (20 0C).
Hold at 14.40 to 14.70 volts until current drops to approximately 70mA.
Battery is fully charged under these conditions, and charger should
either be disconnected or switched to "float" voltage.
"Float" or "Stand -By" Service: Hold battery across constant volt-
age source of 13.50 to 13.80 volts continuously. When held at this
voltage, the battery will seek its own current level and maintain itself
in a fully charged condition.
NOTE: Due to the self- discharge characteristics of this type of bat-
tery, it is imperative that they be charged after 6 -9 months of stor-
age, otherwise permanent loss of capacity might occur as a result of
sulfation.
(v)
14.0
13.0
Q
1 12.0
M
0 11.0
C 10.0
E
H 9.0
8.0
PS -1270
Discharge Characteristics
X111\ Ilk1
■�II��II..�
■�I�a11 ■111 ■1
1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 40
min. X hrs.
Discharge Time
Discharge Time vs. Discharge Current
20
15
10
5
t
2
E
E 1
i=
d
E 30
r
U
N
10
5
0.35 0.7 1.4 3.5 7 14
Discharge Current (A)
Physical Dimensions: in. (mm) Terminals
l _ T "F7" FASTON
tab., 032-
LY N gdck diman
®
® ,a„ "F2" FASTON
y
0250'.0.0
E:DD 32'
quids di ecannad
vim.
5.95 (1sl) =1
(704 °F)
(68 -F)
(32 °F)
Tolerances are + /- 0.04 in. ( +/. 7mm) and +1-0.08 in. ( +/. 2mm) for height dimensions.
All data subject to change without notice.
P'Mr- .
A/ /C
_
SALES & MARKETING IS09001 -2000
CUSTOMERSERVICE
3106 Spring Street
7550 Panasonic Way
Redwood City, CA 94063 USA FM39170
San Diego, CA 92154 USA
Tel: 650-364-5001 Fax: 650-366.3662 -
Tel: 619-661-2030 Fax: 619-661-3648
national - sales @power- sonic.com www.power- sonic.com
customer- service @power- sonic.com
1G „I I I � 1
14 ,?
Final
Voltage
10.5V
70.2V
9.60V �\
9.OV
40%
20%
0%
8.10V
0.35 0.7 1.4 3.5 7 14
Discharge Current (A)
Physical Dimensions: in. (mm) Terminals
l _ T "F7" FASTON
tab., 032-
LY N gdck diman
®
® ,a„ "F2" FASTON
y
0250'.0.0
E:DD 32'
quids di ecannad
vim.
5.95 (1sl) =1
(704 °F)
(68 -F)
(32 °F)
Tolerances are + /- 0.04 in. ( +/. 7mm) and +1-0.08 in. ( +/. 2mm) for height dimensions.
All data subject to change without notice.
P'Mr- .
A/ /C
_
SALES & MARKETING IS09001 -2000
CUSTOMERSERVICE
3106 Spring Street
7550 Panasonic Way
Redwood City, CA 94063 USA FM39170
San Diego, CA 92154 USA
Tel: 650-364-5001 Fax: 650-366.3662 -
Tel: 619-661-2030 Fax: 619-661-3648
national - sales @power- sonic.com www.power- sonic.com
customer- service @power- sonic.com
1G „I I I � 1
14 ,?
Aug 05 2005 11:04AM
p.1
,
r
GENESIS CABLE SYSTEMS '
Customer 8pecif"tion
' ;Port Num
r:
4108
esorlpti
n;
18 AWO 8/C FPL '
?Canplla
UL Standard 1424; NEC.Artiols 780
. "Conawtru
on.
�
;Conducto,.
18 AWO Solid Seri Copper ;
.No, of Co
iductors
8
Type
Polypropyiens 3
Color;,
.Bjk, Red,YMr, Orn, em, B!u ,
Thioknes
0.0091 nom. }
,pj #rr+etsr
0,052" nom"
L„y L
3A" non.
Type :
F'NC
Color,
Rid
Thiokpo
0,010" nam,
al #mrt+rr
01192" nom,
Lepirid tl
tic Prinq
annii wLx ararwe is Awe 0 ju4 rfPs FPL SUN,. UIL Ire
ww xxxxx FT ,
;rtopwa
4
Tamper;
re Ritlnp
-20 to 75 °C
.Ope>'ign
Voltage,
300 Volts max, '
,�,Capaalta
09
20 OR nom. ;
"Ptpo
g� Ohms nom,
00 Rbds
inos
5:32 Ohms/M' at 20°0 '
Florni Rs
ing
UL Vertical Tray
lam ►moo oa
CS: ZI 5002 9 my VZL0-106-Z9Z :x8J 113 SISH39-113AAHOH
[a 'd
CS: ZI 5002 9 my VZL0-106-Z9Z :x8J 113 SISH39-113AAHOH
VISTA-1 28FBPN1 28FBP-24
COMMERCIAL PARTITIONED FIRE AND
BURGLARY ALARM CONTROL PANEL
Designed to integrate seamlessly with CCTV, access control
and Honeywell's full range of fire and burglary components,
the new VISTA- 128FBP provides the ultimate protection of life
and property. The UL Listed commercial fire and burglary
control panel supports up to eight partitions and up to
128 zones /points using hardwired, wireless and V -Plex®
FEATURES
• Eight hardwired zones standard,
expandable to 120 V -Plex
addressable points /zones or
128 wireless points /zones
• Can control eight separate areas
independently (8 partitions)
• Supports commercial wireless fire
and burglary devices
• Stores up to 512 events
• Accommodates 150 user codes and
up to 250 access card holders using
VistaKey
Honeywell
Now UL864 9th Edition Approved
addressable technologies. A diverse line of Honeywell
initiating devices, notification circuits, communication devices,
keypads, RF receivers and relays are also supported. The
VISTA- 11 28FBP has been designed to mount quickly and
easily in an attack resistant cabinet, and is available in 12V
and 24V models.
• Supports V -Plex addressable VistaKey
access control (1 to 8 doors)
• Two on -board notification (bell) circuits
delivering 2.3A @ 12V or 3AA @ 24V
• Automatic smoke detector sensitivity
maintenance testing
• Four -wire smoke reset using onboard
J2 output trigger
• Supports Dynamic Signaling for
AlarmNet Communicators
• Supports Remote Control via
the Internet*
• Supports Internet Alarm Reporting*
• Supports Graphical User
Interface Consoles
• Listed to UL864 9th Edition
• Upload /download via Ethernet`
• Carbon monoxide (CO) zone support
* When used with AlarmNet devices.
VISTA-1 28FBPN1 28FBP-24
COMMERCIAL PARTITIONED FIRE AND
BURGLARY ALARM CONTROL PANEL
ADDITIONAL FEATURES
• Notification Appliance Circuits (two)
- Programmable
- Temporal code compliant
- Individually silenceable
• Programmable on -board auxiliary relay
• False alarm reduction features:
- Exit error logic
- Exit delay reset
- Cross zoning
- Call waiting defeat
- Recent close report
• Supports commercial hardwired,
addressable V -Plex polling loop and
wireless zones
• Hardwired zones
- Provides eight style B hardwired zones
- EOLR supervised for Fire and
UL burglary installations
- Supports N.O. or N.C. sensors
- Individually assignable to any
eight partitions
- Up to 32 two -wire smoke detectors
each on zone one and two (64 total)
- Up to 50 two -wire glassbreak detectors
on zone eight
• Patented addressable V -Plex polling
loop technology
- Supports 120 two -wire zones points
- Global polling technology for
faster processing
- Supervised by panel
- Zones individually assignable to
partitions, notification circuit (bell)
output or auxiliary relay
- 4,000 ft. capability without the
use of shielded cable
- Extender /Isolation bus modules
- Eight zone - Class A and B
expander module
- Eight zone - Class B expander
module
- One zone supervised contact
monitor module
• UL Listed wireless expansion
- Supports up to 128 wireless
zones/points
Honeywell
- Supervised by control for
check -in signals
- Tamper protection for transmitters
- Individually assignable up to
eight partitions
- Supports commercial
wireless smoke detectors
• Access Control integration
- Full integration with PassPoint
Access Control System
Complete Gateway interface of
VISTA and access functions
• Up to eight doors using VistaKey
V -Plex Access Control
• Event reporting
• Local printer of access or VISTA
related events
• Communication
- Phone mapping by zone
response type
- Panel operation during
download
SPECIFICATIONS
Applications • Fusing: Battery input, aux. and
The VISTA- 128FBP control is well
notification (bell) circuit outputs are
suited for a variety of applications as
protected using PTC circuit protectors.
an integrated fire and burglary control. A
All outputs are power limited.
diverse line of Honeywell initiating devices
• Optional 24 -volt power supply, PS 24
supports this extremely powerful control,
supplies two 24 VFW, 1.7A full wave
Some of the applications supported are:
rectified, unfiltered outputs
medical and professional buildings,
Main Dialer
churches or synagogues, office buildings,
schools, strip malls, larger residences
• Line seize: Double Pole
and factory or warehouse environments.
. Ringer equiv.: 0.7B
Electrical
• Primary power: 18VAC @ 72VA
Honeywell No. 1451
• Control panel quiescent current draw:
300mA
• Backup battery:
- 12VDC, 12AH min to 34AAH max
- Lead acid battery (gel type)
• Alarm power: 12VDC, 1.7A max for
each notification (bell) circuit output
Total 2.3A @ 12V
• Aux, standby pwr: 12VDC, 1 A max
• Total power: 2.3A at 12VDC, 3.4A at
24VDC from all sources
• Standby time: 24 hours with 1 A
standby load using 34AAH battery
• Formats: ADEMCO Low Speed,
ADEMCO 4 +2 Express, ADEMCO High
Speed, ADEMCO Contact ID, Sescoa
and Radionics
• Dual phone line capability (using
514ODLM module)
Cabinet dimensions
•18 "Hx14.5 "Wx4.3 "D
Environmental
• Storage temp: 14° F to 158° F
( -10° C to 70° C)
• Operating temp: 32° F to 122° F
(0° C to 50° C)
• Humidity: 85% RH
Honeywell
• EMI: Meets or exceeds the following
requirements:
- FCC Part 15, Class B Device
- FCC Part 68
- IEC EMC Directive
Agency Listings
• UL609 Grade A Local Mercantile
Premises and Mercantile Safe and Vault
• UL611 /1610 Grades A, AA, Central
Station
• UL365 Grades A, AA Police Connect
• UL864 /NFPA72 Local, Central
Station and Remote Station
• UL985
• Factory Mutual
• California State Fire Marshal
• MEA
• CAN /ULC S304 - Central and
Monitoring Station Burglar Alarm Unit
• CAN /ULC S527 - Central Unit for Fire
Alarm Systems
• CAN /ULC S303 - Local Burglar Alarm
Unit
• CAN /ULC S525 - Audible Signal
Appliances
VISTA- 1 28FB PN1 28FB P-24
COMMERCIAL PARTITIONED FIRE AND BURGLARY ALARM CONTROL PANEL
COMPATIBLE DEVICES
Auxiliary Devices
• 6160CR -2 - Red Alpha Keypad
• 4204 - Relay Module, four form C
contacts
• 4204CF - Two supervised output
circuits
• 5881 Series RF receiver
• 5883H RF receiver
• 6220S - System printer used with
4100SM serial module
• 6160CR -2 - Red Fire Keypad
• 6160 - Burglary Keypad
Two -Wire Smoke Detectors
Conventional
• System Sensor
• ESL
• DSC
Horn /Strobes
• System Sensor
• Wheelock
• Gentex
Manual Pull Stations
• 514OMPS -1
• 5140MPS -2
V -Plex (Addressable) Devices
• 4208U Loop Expansion Module
- eight zones
• 4101 SN Single Relay/Zone Module
Product specifications subject to change.
ORDERING
• 4208SNF Class A/B Expander Module
• 4190SN Remote Point Module
- two zones
• 4193SN Two -Zone Serial Interface
Module
• VSI Module
• 4293SN One -Zone Serial Interface
Module
V -Plex Extender /Isolation Modules
• 4297 Extender /Isolator Module
• VSI Isolator Module
V -Plex Smoke Detectors:
• 5193SD
• 5193SDT
V -Plex Passive Infrared Detectors
• 998MX
• IS2500SN
• DT7500SN
V -Plex (Addressable) Contacts
• 4939SN -WH
• 4944SN -WH
• 4959SN
V -Plex Glassbreak Detectors
• FG1625SN
Optional 24V Power Supply
• PS24 - 24V power supply - 3AA
Commercial Wireless Devices
• 5808W3 - Photoelectric
Smoke /Heat Detector
• 5806W3 - Photoelectric
Smoke Detector
• 5809 - Wireless Heat Detector
• 5817CB - Wireless Commercial
Transmitter
• 5869 - Hold -Up Transmitter
• 5881 ENHC - RF Receiver
• 5883H - RF Receiver
Access Control
• VistaKey V -Plex (addressable)
Access Control
• VistaKey -SK Starter Kit
• VistaKey -IX Expansion Kit
Alarm Communications
• 7845i -ENT - Internet/Intranet
Communicator
• 7845GSM - Digital Cellular
Communicator
• 7845i -GSM - Internet and Digital
Cellular Communicator
• GSMCF /iGSMCF - Commercial Fire
Communication Kits (when available)
V128FBP -9 Commercial Fire and Partitioned Burglary Alarm Control Panel 12V Model
V128FBP9 -24 Commercial Fire and Partitioned Burglary Alarm Control Panel 24V Model
For more information: www.honeywell.com /security /hsc
Automation and Control Solutions
Honeywell Security & Communications Honeywell
2 Corporate Center Dr. Suite 100
Melville, NY 11747
1.800.467.5875 LNSTA128FBPD /D
September 2009
www.honeywell.com 0 2009 Honeywell International Inc.