Loading...
HomeMy WebLinkAboutB11-0106NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES x Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11 -0106 Project #: Job Address: 1765 ALPINE DR VAIL Location......: B SIDE Parcel No....: 210312307006 OWNER GURY, ELLEN C. 05/10/2011 PO BOX 2576 MALIBU CA 90265 APPLICANT CLIMATE CONTROL CO OF GWS PO BOX 1042 GLENWOOD SPRINGS CO 81602 License: 129 -M CONTRACTOR CLIMATE CONTROL CO OF GWc PO BOX 1042 GLENWOOD SPRINGS CO 81602 License: 129 -M 05/10/2011 Phone: 970-945-2326 05/10/2011 Phone: 970-945-2326 Description: REPLACE EXISTING FURNACE WITH ONE LENNOX SLP98UH070V36B FURNACE INCLUDES DUCT ADAPTORS, REPAIR OF RETURN DUCTWORK AS NEEDED, VENTING AND /OR REPLACEMENT OF BROKEN VENTS, DRAIN, NEUTRALIZER, ELECTRICAL TO DISCONNECT ONLY, GAS PIPING, START UP INCLUDING COMBUSTION ANALYSIS AND CLEAN UP. Occupancy: Type Construction: Applied.....: Issued... PRJ 11 -0179 05/10/2011 05/24/2011 Valuation: $5,987.00 FEE SUMMARY ,..,.,,.....,,........,.,,,,,,.,,,,,.........,, ......,,,,,,,,.......,,.,.,.,,, Building Permit ------ - - - - -> $125.25 Bldg Plan Check ----- - - - - -> $81.41 Use Tax Fee------------------ - - - - -> $0.00 Electrical Permit ---- - - - - -> $0.00 Elec Plan Check ------ - - - - -> $0.00 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $120.00 Mech Plan Check ---- - - - - -> $30.00 Additional Fees--------------- - - - - -> ($206.66) Plumbing Permit --- - - - - -> $0.00 Plmb Plan Check ---- - - - - -> $0.00 Recreation Fee--------------- - - - - -> $0.00 Investigation------------------ - - - - -> $0.00 Will Call ------------------------------ > $5.00 TOTAL PERMIT FEES --- ---------- > $155.00 Payments------------------------ - - - - -> $155.00 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR,WSPECTION SHALL BE 8:00 AM - 4:00 P". ) nature of Owner Print DE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM r Date combination permit_012811 CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11 -0106 Owner: GURY, ELLEN C. Address: 1765 ALPINE DR VAIL Location: B SIDE combination permit_012811 ON TOWN REQUIRED INSPECTIONS AND STATUSES Permit #: B11 -0106 Owner: GURY, ELLEN C. Address: 1765 ALPINE DR VAIL Location: B SIDE fete «tete.,r,r *,r�,rt, « * * ** «tete. *. rte**** t te« te tete�.. , r r r r* * * « * * *tetete....,r,r *. «,r,r,r *« fete, rt„ r,r,r,rtete,r.,r,r,r *,.,r,rt,t„ rte* tete** .,r..tet„r,r *t, *. * « * «te *,r,r,r, rte *tetet,.te.,rt,tet, «fete *t„r,r* t„rt, * *,r,r,rte,rte Item: 00200 MECH -Rough Item: 00390 MECH -Final combination permit_012811 TOWN OF VAIL, COLORADO Statement Statement Number: R110000533 Amount: $125.00 05/24/201111:34 AM Payment Method: Check Init: SAB Notation: 31969 - CLIMATE CONTROL ----------------------------------------------------------------------------- Permit No: Bll -0106 Type: COMBINATION BLDG PERMIT Parcel No: 2103 - 123 - 0700 -6 Site Address: 1765 ALPINE DR VAIL Location: B SIDE Total Fees: $155.00 This Payment: $125.00 Total ALL Pmts: $155.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- MP 00100003111100 MECHANICAL PERMIT FEES 120.00 WC 00100003112800 WILL CALL INSPECTION FEE 5.00 Project Street Address: 1765 Alpine Dr (Number) (Street) Building /Complex Name: N/A Contractor Information Business Name: Climate Control Company Business Address: 1537 County Rd 130 City Glenwood Springs State: CO Contact Name: Gary Kelly Zip: 81601 Contact Phone: 970- 989 -5258 or 970 - 945 -2326 Contact E -Mail: gkelly @cccgws.com or ecraig @cccgws.com Contractor Registration Number: 129 -M Owner /Owner's Representative Signature (Required) Project #: _ _ PRS k 1-- - 7 9 DRB #: Building Permit #: _ VAIN VIL�R E Lot #: 53 Block # Subdivision: U) -ST FILIg6q I Work Class: New ( ) Addition ( ) Alteration Type of Building: Single- Family ( ) Duplex ( ) Multi - Family ( ) Commercial( ) Other( ) Work Type: Interior (✓) Exterior ( ) Both ( ) Valuation of Work Included Plans In c l uded Work Electrical ( )Yes ( )No ( )Yes ( )No Mechanical (✓)Yes ( )No ( )Yes ( )No 5 Plumbing ( )Yes ( )No ( )Yes ( )No Project Information Building ( )Yes ( )No ( )Yes ( )No Owner Name: Vury, Ellen 2103 - 123 -07 -006 Value of all work being performed: $S1811. Parcel #: ( value based on IBC Section 109.3 & IRC Section 108.3) (For Parcel #, contact Eagle County Assessors Office at (970- 328 -8640 or visit N/A www.eaglecounty.us /patie) Electrical Square Footage Detailed Scope and Location of Work: Replace existing furnace with (1) Lennox SLP98UH07OV36B furnace includes duct adaptors, repair of return ductwork as needed, venting and /or replacement of broken vents, drain, neutralizer, electrical to disconnect only, gas piping, start up including combustion analysis & clean up. Equipment specs are attached. (use additional sheet if necessary) For Office Use Only: Fee Paid: Received From: Cash Check # - CC: Visa / MC Last 4 CC # Auth # exp date: (Suite #) Date Received: MAY 0 fi 2011 TOWN OF VAIL 01- )an -11 I Load Short Form Job: NIA s wrightsoft Date: Mar 28, 2011 Entire House By: TLM Climate Control Company 1537 CR 130, Glenwood Springs, CO 81601 Phone: 970 - 945 -2326 Fax: 970 - 945 -8128 Email tmadara @cccgws.com Web: www.climatecontrolcompany.com e-r oject intormatio For: Don Gury 1765B Alpine Drive, Vail, CO Htg Outside db ( °F) -19 Inside db ( °F) 70 Design TD ( °F) 89 Daily range - Inside humidity ( %) 50 Moisture difference (gr /lb) 68 HEATING EQUIPMENT Make Trade Model GAMA ID Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat �MITM5L Clg Infiltration 85 Method Simplified 70 Construction quality Semi -tight 15 Fireplaces 0 H 50 -27 0 Btuh 0 Btuh 0 'F 899 cfm 0.031 cfm /Btuh 0 in H2O COOLING EQUIPMENT Make Trade Cond Coil ARI ref no. Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 0 SEER Area 0 Btuh 0 Btuh 0 Btuh 899 cfm 0.072 cfm /Btuh 0 in H2O 1.00 12548 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) Room1 660 28904 12548 899 899 Entire House d 660 28904 12548 899 899 Other equip loads 0 0 Equip. @ 0.90 RSM 11331 Latent cooling 0 T/ITAI c' r_r_n nonne AAnnA nnn nnn Bold /italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ^� - #j+ wrightsoft. Right - Suite® Universal 8.0.02 RSU13372 2011- Mar -30 10:28:52 ACCQ ...ng Design Info \Heat Load calculations\2011 \Gury Res 032811.rup Calc = MJ8 Front Door faces: Page 1 SPECIFICATIONS Gas Model No. SLP986A070V36B SLP98UH090V36C SLP98UH09OV48C Heating ' AFUE 97.0% 98.0% 97.5% Performance Maximum Input- Btuh Output - Btuh Temperature rise range - °F Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG /Propane 66,000 88,000 88,000 64,000 85,000 85,000 50-80 60-90 50-80 3.5/10.0 3.5/10.0 3.5/10.0 Minimum Input - Btuh Output - Btuh Temperature rise range - °F Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG /Propane High static - in. w.g. 23,000 31,000 31,000 22,500 30,500 30,500 35-65 35-65 35-65 0.5/1.5 0.5/1.5 0.5/1.5 0.8 0.8 0.8 Connections Intake / Exhaust Pipe (PVC) in. Gas pipe size IPS Condensate Drain Trap (PVC pipe) - i.d. with furnished 90° street elbow with field supplied (PVC coupling) - o.d. 2/2 2 / 2 2/2 1/2 1/2 1/2 1/2 112 1/2 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 NPT 1/2 slip x 1/2 NPT 1/2 slip x 1/2 NPT Indoor Wheel nominal diameter x width - in. Blower Motor output- hp Tons of add -on cooling Air Volume Range - cfm 10 x 9 10 x 9 11 x 11 1/2 1/2 3/4 2-3 2 - 3.5 2.5-4 339-1365 520-1360 528-1770 Electrical Data Voltage (Maximum Amps) Blower motor full load amps Maximum overcurrent protection 120 volts - 60 hertz - 1 phase 7.7 7.7 1 10.1 15 15 L 15 Shipping Data lbs. - 1 package 138 155 1 165 NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non - weatherized furnaces. SPECIFICATIONS Gas Model No. Heating ' AFUE SLP98UH09OV60C SLP98UH11OV60C SLP98UH135V60D 98.2% 97.5% 97.5% Performance Maximum Input- Btuh Output - Btuh Temperature rise range - °F Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG /Propane Minimum Input - Btuh Output- Btuh Temperature rise range - °F Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG /Propane High static - in. w.g. 88,000 110,000 132,000 85,000 106,000 128,000 50-80 50-80 55-85 3.5/10.0 3.5/10.0 3.5/10.0 31,000 39,000 46,000 30,500 38,500 45,000 35-65 35-65 35-65 0.5/1.5 0.5/1.5 0.5/1.5 0.8 0.8 0.8 Connections Intake / Exhaust Pipe (PVC) in. Gas pipe size IPS Condensate Drain Trap (PVC pipe) - W. with furnished 90° street elbow with field supplied (PVC coupling) - o.d. 2/2 2 / 2 2/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 NPT 1/2 slip x 1/2 NPT 1/2 slip x 1/2 NPT Indoor Wheel nominal diameter x width - in. Blower Motor output - hp Tons of add -on cooling Air Volume Range - cfm 11 x 11 11 x 11 11 x 11 1 1 1 3-5 3 - 5 3.5-5 375-2195 554-2125 634-2190 Electrical Data Voltage (Maximum Amps) Blower motor full load amps Maximum overcurrent protection 120 volts - 60 hertz - 1 phase 12.8 12.8 12.8 20 20 20 Shipping Data lbs. - 1 package 165 175 190 NOTE - Filters and provisions for mounting are not furnished and must be field provided. Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non - weatherized furnaces. SLP98UHV / Page 9 DIMENSIONS - INCHES (MM) - HORIZONTAL POSITION LEFT -HAND AIR DISCHARGE r I CONDENSATE TRAP CONNECTION 12 -5/8 (321) (Bottom) Bottom / � AIR 6-9/1P (167) Top Fi nw 9 (229) Bottom 6-1/2 Bottom 2 (51) Top or Bottom 27 -3/4 COMBUSTION (705)i- (146 / AIR INTAKE 9/16 19 -7/16 / (14) (494) �) SUPPLY B v A AIR D OPENING EXHAUST AIR / 1_7/8 (48) OUTLET END VIEW 3-1/4(83) J ELECTRICAL INLET - (Top or Bottom) TOP VIEW GAS PIPING INLET (Top or Bottom) 33 1-1/2(38) 27 -3/4 (838) Front Panel 3/4 (705) ( 3 -1/4 f P 23-1/2 AIR (95) (591) FLOW A RETU RN AIR ENING FRONT VIEW RIGHT -HAND AIR DISCHARGE r � CONDENSATE TRAP CONNECTION (Bottom) AIR FLOW 6-1/2(165) Bottom \r ELECTRICAL INLET (Top or Bottom) 12 -5/8 (321) 9 (229) Top 6 -9/16 (1 67) Bottom 2 (51) Top or Bottom AS PIPING INLET (Top or Bottom) _ 23-1/2 3 -1 A AIR (591) (95) D RETURN C A FLOW A AIR OPENING 3/4 END VIEW (19) FRONT VIEW COMBUSTION AIR INTAKE 09 END VIEW _27 -3/4 1/4 (705) 13) 19 -7/16 (494) 9/16 SUPPLY i (14) AIR OPENING L9/16 END VIEW (14) A Model No. B C D in. mm in. mm in. mm in. mm SLP98UH07OV36B 17 -1/2 446 16-3/8 416 16 406 7 -5/8 194 SLP98UH09OV36C SLP98UH09OV48C 21 533 19 -7 /8 505 19 -1/2 495 9 -3/8 238 SLP98UH09OV60C SLP98UH11OV60C SLP98UH135V60D 24 -1/2 622 23 -3/8 594 23 584 11 -1/8 283 SLP98UHV / Page 14 TOP VIEW �27 -3/4� 1 1-1/2(38) 3 33 O EXHAUST AIR (48) 23-1/2 3 -1 A AIR (591) (95) D RETURN C A FLOW A AIR OPENING 3/4 END VIEW (19) FRONT VIEW COMBUSTION AIR INTAKE 09 END VIEW _27 -3/4 1/4 (705) 13) 19 -7/16 (494) 9/16 SUPPLY i (14) AIR OPENING L9/16 END VIEW (14) A Model No. B C D in. mm in. mm in. mm in. mm SLP98UH07OV36B 17 -1/2 446 16-3/8 416 16 406 7 -5/8 194 SLP98UH09OV36C SLP98UH09OV48C 21 533 19 -7 /8 505 19 -1/2 495 9 -3/8 238 SLP98UH09OV60C SLP98UH11OV60C SLP98UH135V60D 24 -1/2 622 23 -3/8 594 23 584 11 -1/8 283 SLP98UHV / Page 14 SLP98UHV / Page 14 06 -20 -2011 Inspection Request Reporting Page 15 4:37 pm V - City Of Requested Inspect Date: Tuesday, June 21, 2011 Site Address: 1765 ALPINE DR VAIL B SIDE A/P /D Information Activity: B11 -0106 Type: COMBO Sub Type: ADUP Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: GURY, ELLEN C. Contractor: CLIMATE CONTROL CO OF GWS Phone: 970 - 945 -2326 Description: REPLACE EXISTING FURNACE WITH ONE LENNOX SLP98UH07OV36B FURNACE INCLUDES DUCT ADAPTORS REPAIR ggOF''RETURN DUCTWORK AS NEEDED, VENTING AND /OR REPLACEMENT OF UP MMBb�TION A A A DCCLLEANLUP. DISCONNECT ONLY, GAS PIPING, START uested Insbo6tion(s Itein\,,390 MECH -Final Requester: Comments: 989 -0322 Assigned TQ: * * * * * * * * * * ** Actio 0 \1 Inspection History Item: 200 MECH -Roue 06/10/11 - Comment: Item: 390 MECH -Final h ** Approved ** Inspector: JRM Acti TERMINATION VENTS MUST MEET L C.O DETECTORS REQUIRED ROUGH APPROVED Requested Time: 09:00 AM Phone: n Entered By: MHAEBERLE K REPT131 Run Id: 13214