HomeMy WebLinkAboutDRB110147May 17, 201 1
Mr. Bill Gibson
Town of Vail
Department of Community Development
75 South Frontage Road West
Vail, CO 81657
RE: JAFFE DUPLEX, LOT 3, 1456 WESTHAVEN, VAIL, CO
Dear Bill:
In response to your May 17, 2011 e -mail regarding the building
height of the duplex, we will be revising all 8:12 roof pitches to
7 1/2:12. This revision will keep all effected ridge heights below
the 33 feet height limit. We will adjust our drawings and copy
you on the revisions.
Also included is the May 5, 2011 report prepared by HP
Geotech addressing the debris flow conditions.
Please let me know if you have any further questions. We look
forward to getting started with construction.
Sincerely,
SEGERBERG, MAYHEW & ASSOCIATES, ARCHITECTS
Kurt A. Segerberg, A.I.A.
President
KAS /Irt
enc.
MAY 18 2011
TOWN OF VAIL
Segerberg, Mayhew & Associates Architects, P.C., A.I.A.
Mail: P.O. Box 4700 Vail, CO 81658 e-mail: info @smarchs.com http: / /www.smarchs.com
Main Office: Eagle -Vail 101 Eagle Road Bldg 6 Avon, CO 81620 phone: 970 476 4433 fax: 970 476 4608
Denver Office: 12600 West Colfax Avenue, Suite A -140 Lakewood, CO 80215 phone: 303 623 3355 fax: 303 623 2262
DR&I DIg7
HEP, ORTFi- PAWLAK GPQIE _li
May 5, 2011 V n IE Q le E
Tom Jaffe MAY l g Q» 1815 West Gore Creek Drive, #E Vail, Colorado 81657
WN OF VAIL Job No. 110 364A
Subject: Evaluation of Potential Debris Flow impacts to Proposed Duplex
Residence, Lot 3, Glen Lyon Subdivision, Westhaven Circle and Greenhill
Court, Vail, Colorado
Dear Mr. Jaffe:
As requested by Kurt Segerberg with Segerberg Mayhew Architects, we have evaluated
the debris flow conditions at the subject site with respect to the proposed Site Plan dated
April 22, 2011 and more recent rough grading plan provided by Glenn Palmer of Alpine
Engineering on May 3, 2011. We previously conducted a subsoil study for design of
foundations at the site and presented our findings in a report dated November 29, 2010,
Job No. 110 364A.
The proposed building footprint is similar to that shown in our previous report but has
shifted slightly to the west and rotated slightly counterclockwise. The shift and rotation
provides a little more room along the east side to work with grade changes and surface
drainage. The grade change between the uphill Lot 2 and the subject site is proposed to
be handled by a combination of retaining walls and fairly deep swales. We suggested to
Glenn Palmer to revise the upper retaining wall of the spa area to be 1 foot above the
drainage swale for freeboard. The driveway entrance for the uphill, primary unit has been
shifted downhill to the west and the ground floor level has been raised somewhat which
will provide at least one foot of fall from the building to the drainage pan of Westhaven
Circle. Because potential debris flow impact to the lot will be from uphill across
Westhaven Circle, we recommended that a civil engineer design the grading for the
project. We understand that Alpine Engineering has been retained and is working to
complete the grading plan started by the architect.
The subject site is located in a moderate debris flow hazard area according to Town of
Vail (2000). The potential flood impact to the property is fiom the drainage basin above
the Glen Lyon Subdivision and flow across the alluvial fan upon which the property is
located. Considering the property location in the lower part of the moderate hazard area,
and that considerable development has occurred uphill in the subdivision, it appears that
the potential impact to the property would be mainly from mud flood rather than debris
flow. Mitigation of this type of flow can usually consist of on -site drainage features to
route the mud flood flows down Westhaven Circle and around the east side of the lot by
Tom Jaffe
May 5, 2011
Page 2
earth berms, well defined swales and retaining structures. We recommend these features
have a minimum depth or height of at least 2 feet and be designed to deflect flows
downhill rather than intercept flows that could cause flow material to backup on the
property. Based on these conditions and the rough grading plan provided by Glenn
Palmer, in our opinion, the grading plan and building layout for the project can be
designed such that the development will not increase the hazard to adjacent public or
private properties including buildings, structures and road and utility right -of -ways.
If you have any questions or need further assistance, please call our office.
Sincerely,
HEPWORTH - PAWLAK GE CHNICAL, INC.
N- . P, I 4.
a u ca 1
0
Steven L. Pawlak, P. a
1622,
Rev. by: DEH
SLPlksw
cc: Segerberg Mayhew Architects - Kurt Segerberg (k seaerb erg smarch,.corn )
Reference:
Town of Vail, 2000, Official Debris Flow Hazard Map, Town of Vail, prepared by Town
of Vail, Vail, Colorado (adopted by Town Council on October 17, 2000).
Alpine Engineering - Glenn Palmer, PE (Iit�
JVU `IO. t1U304A
Stech
ep
Application for Design Review
Changes to Approved Plans
General Information: This application is for all changes to approved plans prior to Certificate of Occupancy. An ap-
plication for Design Review cannot be accepted until all required information is received by the Community Development
Department. Design review approval expires one year from the date of approva d and
construction commences. D E� E W r
Submittal Requirements: I
1. Three (3) Copies of all pertinent approved plans with illustrated, labeled char � MAY 10 2011
2. Joint Property Owner Written Approval Letter, if applicable
Fee: $20
T(') 0 1= `JA ,
Single Family_ Duplex Multi- Family Commercial
Description of the Request: �� G/ ,�
Physical Address: � -� ���� �� � �A�"-� ^
Parcel Number: �I � aeew ��l (Contact Eagle Co. Assessor at 970 - 328 -8640 for parcel no.)
Property Owner:
Mailing Address: P. = /.qc�X
V-A-JL, e� f&/
Phone: 1F 3
Owner's Signature:
Primary Contact/ Owner Representative:
Mailing Address: -/Pot, .. !. , el e
E -Mail: Fax:
_ Phone: �� r '/` —
For Office Use Only:
Cash_ CC:
Visa / MC Last 4 CC #
Exp. Date: _
gA th # Check # 9 �
Fee Paid:
•�
Received From:
�d° C
Meeting Date:
cot
DRB No.: `��
1 � (� 1�-{ �—
Planner:
��—
Project No:
Zoning:
Location of the Proposal
Land Use:
Lot: Block: Subdivision:
10 -4/1( -UO
Department,' of Community Developmel
75 South Frontage Rog
Vail
ky r
01 -Jan-11
(� /,,, ���
PROPOSED MATERIALS
Building Materials Type of Material Color
Roof
Siding
Other Wall Materials
Fascia
Soffits
Windows
Window Trim
Doors
Door Trim
Hand or Deck Rails
Flues
Flashing
Chimneys
Trash Enclosures
Greenhouses
Retaining Walls
Exterior Lighting
Other
Notes:
Please specify the manufacturer's name, the color name and number and attach a color chip.
f: \cdev\ forms\ permits \Planning \DRB \DRB_Changes to approved Plans_010111
� e,- W -)
PROPOSED LANDSCAPING
Botanical Name
PROPOSED TREES
AND SHRUBS
EXISTING TREES
TO BE REMOVED
Minimum Requirements for Landscaping:
Common Name Quanti Size
Deciduous Trees — 2" Caliper
Coniferous Trees — 6' in height
Shrubs — 5 Gal.
Type Square Footage
GROUND COVER
SOD
SEED
IRRIGATION
TYPE OF EROSION CONTROL
Please specify other landscape features (i.e. retaining walls, fences, swimming pools, etc.)
f: \cdev\ forms\ permits \Planning \DRB \DRB_Changes to approved Plans_010111
LETTER OF TRANSMITTAL
P.O. Box 4700
VAIL, COLORADO 81658
(970) 476 -4433
Fax (970) 476 -4608
TO Bill Gibso
o Vail Planner
75 South Frontage Road
Vail, CO
WE ARE SENDING YOU
❑ Shop drawings
❑ Copy of letter
® Attached
® Prints
❑ Change order
DATE 05 -09 -11 JOB NO. 33006.00
ATTENTION Bill
RE: Jaffe Duplex — Lot 3 Permit Set
❑ Under separate cover via the following items:
❑ Plans ❑ Samples ❑ Specifications
❑ Transparencies
COPIES DATE NO. DESCRIPTION
1 05 -03 -11 Jaffe Duplex — Lot 3 Permit Set 05 -03 -11
❑ For approval
❑ Approved as submitted
❑ Resubmit copies for approval
® For your use
❑ Approved as noted
❑ Submit copies for distribution
❑ As requested
❑ Returned for corrections
❑ Return corrected prints
❑ For review and comment
❑
❑ FOR BIDS DUE
❑ PRINTS RETURNED AFTER LOAN TO US
REMARKS
COPY TO Flit
Ip1 MAY 10 2011 L
luu
TOWN OF VAIL
SIGNED: Kurt
If enclosures are not as noted, kindly notes us at once
May 9, 2011
Mr. Martin Haeberle
Chief Building Official
Town of Vail
75 South Frontage Road West
Vail, CO 81657
RE: JAFFE DUPLEX, LOT 3, 1456 WESTHAVEN, GLEN LYON SUBDIVISION, RESPONSE
TO BUILDING DEPARTMENT COMMENTS DATED APRIL 14, 201 1.
Dear Martin:
Per your request, enclosed are four sets of revised construction documents. The
most notable changes to the duplex have been the modifications to the site and
grading plan and some slight adjustments to the primary and secondary floor
elevations. We raised the entry level and upper level of the primary unit by l' -6 ".
The primary entry drive was moved to the west to provide better drainage for this
unit. The secondary unit was raised 6" and a site retention wall system is being
designed for the east side of the secondary unit. The building footprint locations
on the site remain the same.
The revisions and responses to your April 14, 2011 letter are as follows:
Architectural Comments:
Heat tape will be used on all gutters and downspouts. See note on Sheet
A1.0 snow fence retention devices will not be used.
2. Attic ventilation will be provided though gable roof at secondary unit. See
Sheet A5.1. Five hundred (500) square feet will be ventilated with a
minimum vent size of 1.6 square feet per 1203.2 IBC.
3. Attic access will be provided as shown on Sheet A3.4.
Sheet Survey
Attached are four stamped surveys as revised by Eagle Valley Engineering
per Public Works request dated April 5, 2011.
Sheet A2.0
The grading plan has been reviewed by Alpine Engineering and HP
Geotechnical Inc. The plan has addressed the moderate debris hazard
flow.
Segerberor Mayhew & Associates Architects, P.C., A.I.A
Mail: P.O. Box 4700 Vail, CO 81658 e -mail: info @smarchs.coin http: / /www.smarchs.coi
Main Office: Eagle -Vail • 101 Eagle Road, Bldg. 6 Avon, CO 81620 • phone: 970 476 4433 • fax: 970 476 4608
Denver Office: 12600 West Colfax Avenue, Suite A -140 Lakewood, CO 80215 phone: 303 623 3355 fax: 303 623 2262
Mr. Martin Haeberle
May 9, 2011
Page Two
2. Retaining walls will be reviewed by structural engineer and geotechnical
engineer. Design is being coordinated.
Sheet A7.0
1. Party wall has been extended to under side of roof sheathing. See Detail
4/A7.0.
2. Gable separation requires 5/8" Type "X" Gyp. Bd. at ceiling and wall
separations. See Detail 1 /A6.0.
3. Regarding spa cover, see Detail 5/A7.0. Also see attached Specification.
Spa to be provided by "Hot Springs Company ".
Sheet A8.0
1. All windows and glazed doors to have .30 U.factor. See Window Schedule
note Sheet A8.0.
2. See stone veneer attachment clarification note on masonry addendum
Detail 1 W.O.
3. See note for weep location in stone veneer. Detail 1 /A7.0.
Sheet A8.1
1. See clarification for corner insulation detail 14/A8.1 and 15/ A8.1.
Sheet A9.0 thru 9.4
1. See notes on Sheet A9.0 and A9.3 of Electrical Plans for locating permanent
certificate per ResCheck requirement.
2. See located carbon monoxide detectors on Electrical Plans. Typical shown
outside all bedrooms. Sheets 19.0, A9.2, A9.3 and A9.4.
Structural Comments
1. See attached response dated April 18, 2011 from S.A. Miro Structural
Engineers.
Mr. Martin Haeberle
May 9, 2011
Page Three
2. Foundation drainage will be reviewed during the excavation and
foundation work. Generally, drainage will be installed at all perimeter
footings.
Plumbing Comments
1. Please refer to civil engineering drawings and notes.
Mechanical Comments
1. See Mechanical Sheet A3.0.
Electrical Comments
1. See notes on Sheet A9.0 by New Electrical.
2. See notes on Sheet A9.0 by New Electrical.
3. See notes on Sheet A9.0 by New Electrical.
Load Calculations
1. See attached load calculations per 220 -80 for heat tape.
Please let me know if you need any further clarifications. We look forward to
getting started with construction.
Sincerely,
SEGERBERG, MAYHEW & ASSOCIATES, ARCHITECTS
Kurt A. Segerberg, A.I.A.
President
KAS /Irt
enc.
TOWN OF VAIL, COLORADO Statement
Statement Number: R110000443 Amount: $20.00 05/10/201104:43 PM
Payment Method: Check Init: LC
Notation: 49319 / KURT A.
SEGERBERG
-----------------------------------------------------------------------------
Permit No: DRB110147 Type: DRB -Chg to Appr Plans
Parcel No: 2103 - 124 - 0200 -6
Site Address: 1456 WESTHAVEN CR VAIL
Location:
Total Fees: $20.00
This Payment: $20.00 Total ALL Pmts: $20.00
Balance: $0.00
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------- - - - - -- ------------------------ - - - - -- ------ - - - - --
DR 00100003112200 DESIGN REVIEW FEES 20.00
Bill Gibson
From: Bill Gibson
Sent: Tuesday, May 17, 20118:59 AM
To: Kurt Segerberg (ksegerberg @smarchs.com)
Subject: Jaffe (DRB110147)
Hey Kurt,
The proposed changes to the new Jaffe duplex at 1456 Westhaven Circle exceed the maximum allowable building height
limit of 33 feet as measured to natural grade below:
• Primary Unit Ridge 8116' -11" measures 33.2 feet from natural grade.
• Secondary Unit Ridge 8104'- 1 -1/2" measures 33.3 feet from natural grade.
Please submit plans corrections addressing this issue at your earliest convenience.
Sincerely,
Bill