Loading...
HomeMy WebLinkAboutA11-0020TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Permit #: A 11 -0020 Job Address: 996 PTARMIGAN RD VAIL Status ...: ISSUED Location.....: Applied..: 05/12/2011 Parcel No...: 210108115003 $0.00 Issued. .. 05/23/2011 Project No Investigation ---- > Expires. .: 11/19/2011 OWNER OML INVESTMENTS INC 05/12/2011 Will Call --------- > $0.00 975 AMERICAN PACIFIC DR STE 104 $408.00 TOTAL FEES - -> HENDERSON BALANCE DUE--- - - - - -> $0.00 NV 89014 Approvals: APPLICANT THUL ELECTRONIC SYSTEMS 05/12/2011 Phone: 970 - 949 -4638 Item: 05600 FIRE DEPARTMENT P O BOX 534 AVON Action: AP CO 81620 License: 112 -S CONDITIONS OF APPROVAL CONTRACTOR THUL ELECTRONIC SYSTEMS 05/12/2011 Phone: 970 - 949 -4638 P O BOX 534 AVON CO 81620 License: 112 -S Desciption: FIRE ALARM SYSTEM FOR SINGLE FAMILY HOME. Valuation: $3,200.00 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Electrical --------- > $0.00 Total Calculated Fees - -> $408.00 DRB Fee --------- > $0.00 Additional Fees ---------- > $0.00 Investigation ---- > $0.00 Total Permit Fee--- - - - - -> $408.00 Will Call --------- > $0.00 Payments ------------------ > $408.00 TOTAL FEES - -> $408.00 BALANCE DUE--- - - - - -> $0.00 Approvals: Item: 05600 FIRE DEPARTMENT 05/23/2011 mvaughan Action: AP CONDITIONS OF APPROVAL ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinAces of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN SIGN t PHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF TOWN OF VAIL, COLORADO Statement Statement Number: R110000525 Amount: $408.00 05/23/201101:56 PM Payment Method: Check Init: DR Notation: CK# 17508 RICK ----------------------------------------------------------------------------- Permit No: All -0020 Type: ALARM PERMIT Parcel No: 2101 - 081 - 1500 -3 Site Address: 996 PTARMIGAN RD VAIL Location: Total Fees: $408.00 This Payment: $408.00 Total ALL Pmts: $408.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------- - - - - -- ------------------------ - - - - -- ------ - - - - -- BP 00100003111100 FIRE ALARM PERMIT FEES 120.00 PF 00100003112300 PLAN CHECK FEES 288.00 Community Development 75 South Frontage Road Vail, Colorado .81657 Tel: 970 - 479 -2128. Fax: 970 - 479 -2452 Web: www.vailgov.com men ow0 FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Project Street Address: 996 PTARMIGAN (Number) (Street) Building /Complex Name: Contractor Information: (Suite #) Company: THUL ELECTRONICS Company Address: PO BOX 534 City. AVON State: CO Zip: 81620 Contact Name: ROB PIERANGELI Contact Phone: 970- 949 -4638 E -Mail ROB @THULELECTRONICS.COM Town of Vail Contractor Registration No.: 112 -S Deborah X Shaner Contractor Signature (required) Property Information Parcel #: 2101- 081 -15 -003 (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us /patie) Tenant Name: Owner Name: PTARMIGAN VAIL LLC Complete Valuation for Fire Alarm Permit: Fire Alarm $: $3200 Office Use: /� Project #: P9t I M — 0 311 Building Permit #: BID - 001 / , J Alarm Permit #: /9// Lot #: Block # Subdivision: Detailed Description of Work: FIRE ALARM SYSTEM FOR SINGLE FAMILY HOME. (use additional sheet if necessary) Does a Fire Alarm Exist? Yes( ) No ( , ) Does a Sprinkler System Exist? Yes (v ) No( ) Work Class: New(,) Addition( ) Remodel( ) Repair( ) Retro -Fit ( ) Other( ) Type of Building: Single - Family Duplex ( ) Multi - Family ( ) Commercial ( ) Restaurant ( ) Other ( ) Date Received: TOWN OF VAIL (�LC�C��`ICS(� �( MAY 12 ZOII IUI 29- May -09 ... Security NetworX NX- 148E -RF touchpad The NX- 148E -RF is an integrated 48 -zone wireless receiver LCD keypad with traditional design and an easy -to -read, customizable display. It is compatible with all NetworX control panels (except commercial firel. The NX- 148E -RF offers the convenience of having an integrated wireless receiver built into the keypad along with standard hardwire features A removable door allows the user to swing the door down or simply take it off for use. The NX- 148E -RF emergency keys are highlighted on the keypad and can be programmed to contact and send complete information to a responding police, fire or EMS unit with just one touch. There are also five pre - programmed touch keys that allow the most common functions to be performed with ease. All keys on the NX- 148E -RF are backlit to ensure error -free operation — even in a dark room. The NX- 148E -RF is cost - effective and easy to install. Designed for functionality and compatibility, the NX- 148E-RF is the right keypad to fit any application. Features • Integrated 48 -zone wireless receiver • Optimize wireless reception by having the keypad /receiver in the best location • LCD, easy -to -read programmable display • Traditional design to go with any decor • Compatible with all NetworX series control panels (except commercial fire) • Easy to install, program and maintain NetworX NX- 148E -RF wireless LCD display keypad f b% i 4A Americas 503 -885 -5700 888 -GE- SECURITY (437 -3287) foxbock 800 - 483 -2495 info @gesecurity.com www.gesecurity.com Asia tel 852-2907-8108 fax 852- 2142 -5063 Australia tel 61 -3- 9259 -4700 fax 61 -3- 9259 -4799 Europe tel 32-2-725-11-20 fax 32 -2- 721 -86 -13 Latin America tel 305 - 593 -4301 fax 305 -593 -4300 Specifications Electrical • Current: 75 to 110 mA nominal Environmental • Operating temperature: 32 to 120 °F (0 to 49 °C) Physical • Dimensions (HxWxD): 5.30 x 6.20 x 1.30 in. (135 x 157 x 33 mm) • Construction: ABS plastic • Color: White Ordering information NX- 148E -RF NetworX 48 -zone LCD display keypad with door and integrated wireless receiver © 2006 GE Security. As a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest product specifications, visit GE Security online at www.GESecurity.com or contact your GE Security sales representative. 20060322 DS nx- 148e -rf 466 -70.8 E S L P R O D U C T I N F O R M A T I O N B U L L E T I N W . �- r 449/448 SERIES Self- Diagnostic, Four. Wire, Photoelectric Smoke Detectors Model numbers: 449AT, 449C, 449CT, 449CRT, 449CST, 449CSTE, 449CSRT, 449CSRH, 449CTE ®L FM ULC usreo APPROV California State Fire Marshal Approved MEA (New York City) Approved ULC model numbers: 448AT, 448C, 448CT, 448CST, 448CSRH, 448CTE • Intelligent, self- diagnostics • On -site maintenance alert • Field replaceable optical chamber • Low - profile design • Plug -in terminal block • Advanced false alarm immunity The ESL 449/448 Series self- diagnostic, four -wire smoke detectors continually monitor their own sensitivity and operational status, and provide a visual trouble indication if they drift out of sensitivity range or fail internal diagnostics. This unique, patented technology meets NFPA 72 field sensitivity testing requirements without the need for external meters. Additional diagnostic information is activated by applying a magnet near the detector's integral reed switch. This initiates a self- diagnostic routine and provides visual indication of sensitivity level, or if service is required. This series is easily cleaned by simply replacing ESL's proprietary field- replaceable optical chamber. All models are designed to reduce false alarms from dust, insects, RFI, and external light. An integral combination rate -of -rise and fixed 135 °F (57 0 C), 50 -foot rated, heat sensor is available with all "T" model detectors (see selection guide), allowing latching of the alarm for either smoke or heat. The 449CSRH includes an isolated alarm output for heat and activates an internal non - latching sounder (local alarm) for smoke, making it ideal for motel /hotel and dormitory rooms where smoking is permitted. continued ESL 449 Series Smoke Detectors Architectural and Engineering Specifications The ESL 449 Series low- profile, self- diagnostic, four -wire smoke detectors work on the light scattering principle. A pulsed infrared light- emitting diode serves as the light source, and a high -speed photodiode as the sensing element. When the amount of light reflected onto the photodiode reaches the sensitivity setting, the smoke sampling rate increases. Three (3) successive smoke sensings above the sensitivity setting are required to sound an alarm. This design has superior protection against false alarms caused by dust, insects, RF and ambient - light. A confirmed alarm causes the normally flashing power indicator LED to light continuously and the alarm relay to operate. A trouble indication is automatically displayed by flashing the LED every second. This meets NFPA 72 field sensitivity testing requirements. An internal 85 dB horn (available in "S" models) emits a temporal 3 when the detector alarms and a steady tone when power polarity is reversed. Product Data Feature Sensitivity .................. ............................... 3.1 - 1.0 % /ft. (max.) Isolated Fixed Temp. 3.1 + 0.50 % /ft. (min) Operating temp. range ............... 32 °F to 120 °F (0 °C to 50 °C) Operating humidity range ..... ............................... 0 to 95% RH Minimum voltage - C, CT, CRT, CST, CSRT, CSRH , - CSTE .......................................... ............................... 8.5V - AT ............................................... ............................... 5.1V Maximum voltage - C, CT, CRT, CST, CSRT, CSRH, CSTE............................................ ............................... 33V AT................................................. ............................... 27V Maximum ripple (peak to peak) ......... ............................... 10% Typical average standby current .......... ...........................70µA - CSTE ......................................... ............................... 23mA Typical alarm current - C, CT and AT ............................ 15mA - CRT ........................................... ............................... 31 mA Selection Guide The proprietary optical sensing chamber is field replaceable, allowing quick and easy cleaning and maintenance. Models with auxiliary relays are approved for releasing service. This low profile product is equipped with a hinged cover, a concealed tamper- resistant latch, and insect screens. Wiring terminates in plug -in, clamp -type screw terminals. Detectors mount to a standard single -gang electrical box, a four -inch octagonal, four -inch square electrical box, or WIREMOLD 5739 fixture box. Smoke Detector Spacing On smooth ceilings (as defined in NFPA 72), spacing of 30 feet (9.1 meters) may be used as a guide. Other spacing may be used depending on ceiling height, high air movement, and other conditions or response requirements. 0 - CST ........................................... ............................... 40mA -CSRT, CSRH, CSTE ................. ............................... 51mA Typical avg. polarity reverse current - CST, CSRT, CSTE, and CSRH . ............................... 10mA Sounder specifications .......... ............................... 85 dB at 10' Heat detector specifications fixed temperature ...... ............................... 135 °F (57.2 °C) rate of rise .... 15 °F /min. & >105 °F (8.3 °C /min. & >40.6 °C) Auxiliary relay contacts 2A @ 28 VDC or 120 VAC (resistive) Alarm contacts ........................ 500 mA @ 36 VDC (resistive) Field wiring size ................... ............................... 14 - 24 AWG Packaging ....................... 10 detectors are packed in a carton Color ..................... ............................... white cover /white base with UV inhibitor to prevent yellowing Listing .............................. UL 268, ULC FM, CSFM and MEA Designator Feature Description H Isolated Fixed Temp. Isolated fixed 135oF (57 °C) and rate of rise heat detector, independently trips the LED and alarm and Rate of Rise output. Smoke detector activates internal sounder (local alarm) and auxiliary relay, but Heat Detector does not latch. Approved as both single station smoke alarm and system heat detector. Ideal for hotel, motel and dormitory rooms where smoking is allowed. R Auxiliary Relay Used to activate other devices such as elevator recall, door holders, strobes, etc. Listed for releasing service. S Built -in Sounder 85dB built -in sounder alarms when smoke is detected or when power wiring polarity is reversed. T Intergrated Fixed Intergrated Fixed 135 °F (57 °C) temperature and rate of rise heat detector. Temp. and Rate of Either heat detector or smoke detector can trip and latch LED and alarm protection. Rise Heat Detector relay outputs. E Built -in end of line Relay is normally energized and will trip with loss of power. Can also provide notification power supervision relay when detector needs maintenance. interlogi.�.. PH 503.692.4052 USA a Canada: 800.547.2556 TeeMical Service: 800.648.7424 fa=BadL 800.483.2495 www.sentfol.com www.interlogixsecurity.com 02001 Interlogi, Inc. Interlogm Laddx, ESL, IT1 and Sentrol are trademarks of Interlogix,Inc. E -3965 Rev 6 - 1 101 SYSTEM SENSOR 5600 Series Mechanical Heat Detectors System Sensor's 5600 series mechanical heat detectors offer a low -cost means for property protection against fire, and for non -life- safety installations where smoke detectors are inappropriate. Features • Multiple configurations for installations: - Single- and dual- circuit models - Fixed temp and combination fixed- temp /rate -of -rise 135 °F or 194 °F ratings. Plain housing for residential installations (Model 5601 P) • Easy -to -use terminal screws • A broad range of back box mounting options: - Single gang - 3.5' and 4 Octagonal - 4'square with square to round plaster ring Reversible mounting bracket Agency Listings @ <FM > MEAD LISTED APPROVED approved S"101 wa 12o9227 Multiple configurations. The 5600 series offers a full -line of configurations to accommodate a broad range of applications. Both single- and dual- circuit models are available for low- and high - temperature ratings with either fixed temperature or combination fixed temperature /rate -of -rise (ROR) activation. The FOR element of the fixed /ROR models is restorable to accommodate field- testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single -gang and octagonal back boxes. And these models accommodate four - square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both Flush- and surface -mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed /rate -of -rise units are marked FX /ROR.The 5600 series also provides a post - activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. ifications Mechanical heat detector shall be a System Sensor 5600 series model number listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single- circuit or a dual- circuit type, normally open. The detector shall berated for activation at either 135 °F (57`C) or 194`F (90 °C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature /rate -of -rise thermal sensor. The rate -of -rise element shall be activated by a rapid rise in temperature, approximately 15 °F (8.3 °Q per minute. The detector shall include a reversible mounting bracket for mounting to 3 - inch and 4 - inch octagonal, single gang, and 4 - inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14 -22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate -of -rise element of combination fixed temperature /rate -of -rise models shall be restorable, to allow for field- testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Ph ysica I/ rating Specifications Maximum Installation Temperature 5601 P, 5603, 5621, and 5623: 100 °F (38 °C) 5602, 5604, 5622, and 5624: 150 °F (65.6 °C) Operating Humidity Range 5 to 95% RH non - condensing Dimensions with mounting bracket Diameter: 4.57 inches (I 1.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 135 °F (57 °C) 5602, 5604, 5622, and 5624: 194 °F (90 °C) Weight 6 oz. (170 grams) Rate -of -Rise Threshold 15 °F (8.3 °C) rise per minute (models 5601 P, 5602,562 1, and 5622 only) Mounting 3 -inch octagonal back box 4 -inch octagonal back box Single gang back box 4 -inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact Ratings 6- 125VAC / 3A 6 -28VDC / 1 A 125VDC / 03A 250VDC / 0.1 A Input Terminals 14 -22 AWG eoa% � 0") (C X1 0 5601P 5602,5622 5603,5623 5604,5624 5621 Ordering Information 5601 P Single Non 1 35 ° ( 57 °C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194 °F (90 °C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 13 ° F (57 °C) Fix T 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194 °F (90 °C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135 °F (57 °C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194 °F (90 °C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135 ° (57 °C) F T empe r ature 25 f eet x 25 f eet ( 7. 62 m x 7.62m) 5624 'NOTE: Refer Dual to NFPA72 Lettering guidelines for spacing 194 °F (90 °C) Fixed Temperature reductions when ceiling heights exceed 10 feet. 25 feet x 25 feet (7.62m x 7.62m) 02-65y,ternSen.,. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 P' :wl;ec to change ,�m muceMws SENSOR Phone: 800- SENSOR2 • Fax: 630-377-6495 trrnet,Ct'ri— lon,in„wangthela­T ryn„orm:earaO,eet A05- 0351 - 002.11/06.01676 SYSTEM SENSOR C01 224T Carbon Monoxide Detector with RealTest "Technology The System Sensor C01224T CO detector provides early warning by using electrochemical sensing technology to measure carbon monoxide levels in the air. Features RealTest" technology allows installer to test detector with CO gas Full compliance with UL 2075 A code required trouble relay • Wiring supervision with SEMS terminals A six year end -of -life timer 12/24 VDC • A current draw of 20mA in standby and 40mA in alarm • Versatile mounting for wall and ceiling • Electrochemical sensing technology Agency Listings U� LISTED µ With RealTest" technology, the CO gas sensing cell of the COI 224T CO detector can be tested using a carbon monoxide gas agent. Simply hold the test button for two seconds. After the alarm cycle (temp 4) the green LED will flash about once per second, indicating that the detector is ready to accept CO for testing. Spray a small amount of CO into the detector per the installation instructions, and within seconds the detector will alarm, indicating successful gas entry. If dangerous amounts of carbon monoxide is detected, the COI 224T detector will alert residents by sounding and flashing a temp -4 signal alarm. Protection is guaranteed 24/7 by a central station, regardless of whether residents are away from home, sleeping or already suffering from the effects of CO. This specific device is designed for system operation. The detector is fully listed to UL 2075. It offers a code required trouble relay to send a sensor failure or end -of -life signal to the control panel and the central station. It also uses SEMS -type terminal Philips head screws to provide a quicker and more positive wiring connection and code required wiring supervision. The C01 224T detector offers a low current draw, allowing more devices to be connected to the panel without having to purchase a more expensive panel or an extra power supply. The C01 224T model will operate on most industry security and fire alarm control panels because it is is a 12/24 VDC detector. COI224T Carbon Monoxide Detector Specifications Carbon monoxide detector shall be a System Sensor model number CO1224T, listed to Underwriters Laboratories UL 2075 for Gas and Vapor Detectors and Sensors.The detector shall be equipped with a sounder and a trouble relay. The detector's base shall be able to mount to a single -gang electrical box or direct (surface) mount to the wall or ceiling. Wiring connections shall be made by means of SEMS screws. The detector shall provide dual color LED indication, which blinks to indicate normal standby, alarm, or end -of -life. When the sensor supervision is in a trouble condition, the detector shall send a trouble signal to the panel. When the detector gives a trouble or end -of -life signal, the detector shall be replaced. The detector shall provide a means to test CO gas entry into the CO sensing cell. The dete ctor shall provide this with a test mode that accepts CO gas from a test agent and alarms immediately upon sensing CO entry. Operating Voltage 12/24VDC Audible Signal 85 dB in alarm Standby Current 20 mA Alarm Current 40 mA (75 mA test) Alarm Contact Ratings 0.5 A@ 30VDC Trouble Contact Ratings 0.5 A @ 30 VDC Physical Specifications Size Length: 5.1 in, Width: 3.3 in, Height: 1.3 in Approximate Weight 7 oz Operating Temperature Range 32 °F to 104° F (0 °C to 40'Q Operating Humidity Range 22 to 90%RH Input Terminals 14 to 22 AWG Mounting Single -gang back box; surface mount to wall or ceiling Operation Modes liperationuioae Green LED Red LED Sounder Normal (standby) Blink 1 per mi — — Alarm — Blink in temp 4 pattern Sound in temp 4 pattern RealTest` Feature: The System Sensor COI 224T carbon monoxide detector with RealTest" can evaluate the functionality of the CO sensing cell using canned test agent r � Verify CO sensing at the control panel. The detector will automatically exit RealTest alarm mode after about 20-60 seconds. NOTE: Check with local codes and the AHJ to determine whether or not a functional gas test is desired for an installation. Hush Feature: Pushing theTest/Hush button will silence the sounder for 5 minutes (except in RealTest mode). Trouble Feature: When the detector is in a trouble condition, it will send a trouble signal to the panel. End-of-life Timer: After the detector's internal sensor has reached the end of its life, a trouble signal will be sent to the panel. This will indicate that it is time to replace the detector. An electrochemical carbon monoxide detector lifespan is approximately six years, and the detector must be replaced by the date marked on the inside of the product. Ordering Information Part No. Description C01224T 12124 volt, 4 -wire system - monitored carbon monoxide detector with RealTest Technology SYSTEM Ohio Avenue • St. Charles, IL 60174 neap omos " c han g e sensor SENSOR" . rnf � nclud dw W" of0 et for 800 SENSOR2 •Fax: 630 377 495 " P ' "" n m g S "`'" -WN- "`�" °r""�a"'� s A05-0437-000•flA8.11953 Push and hold theTest/Hush button for two seconds to enter RealTest mode. The green LED will flash once every second to indicate RealTest mode has started. Spray canned CO agent into the detector. SYSTEM SENSOR Selectable Output Horns, Strobes, and Horn /Strobes SpectrAlert °Advance selectable - output horns, strobes, and horn /strobes are rich with features guaranteed to cut installation times and maximize profits. The SpectrAlert Advance series of notification appliances is designed to simplify installations, with features such as plug in designs, instant feedback messages to ensure correct installation of individual devices, and 11 field - selectable candela settings for wall and ceiling strobes and horn /strobes. When installing Advance products, first attach a universal mounting plate to a four -inch square, four -inch octagon or double -gang junction box. The two -wire mounting plate attaches to a single -gang junction box. Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounting plate. Finally, attach the horn, strobe or horn /strobe to the mounting plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the product's pins into the mounting plate's terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor strobes and horn /strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or dry applications. Features 4 Electrically compatible with existing SpectrAlert products Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela Plug -in design Field selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185 Same mounting plate for wall- and ceiling -mount units Shorting spring on mounting plate for continuity check before installation •Tamper resistant construction Outdoor wall and ceiling products rated from -40 °F to 1517 Design allows minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts Rotary switch for horn tone and three volume selections Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements Outdoor products rainproof per UL 50 (NEMA 3R) • Compatible with MDL sync module Agency Listings SIGNALING u� F M MEA 125 1653:I86 (Ir1d00r strot»s) strobes) 73 6531&1( 11 ! 125 653:IhaNSrrobe; N8 ( LISTED APPROVED approved Ch me/srrobe%) 1135 - 1653:1" (hMS,, chimes) �� Aft "21 r o m 8 • t e m S e n s o SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes and horn /strobes shall mount to a standard 4 x 4 x 1'k -inch back box, 4 -inch octagon back box or double -gang back box.Two -wire products shall also mount to a single -gang 2 x 4 x 1' /8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit` Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync-Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlent Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. Strobes and horn /strobes shall have field - selectable candela settings including 15,15/75, 30, 75, 95,110, 115, 135, 150,177, 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn /Strobe Combination The horn /strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary - signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three- pattern and a non - temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder The horn on horn/strobe models shall operate on a coded or non -coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn /strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit. The products shall be listed for use with a System Sensor outdoor /weatherproof back box with half inch and three - fourths inch conduit entries. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn /strobe models over a single pair of wires. The module shall mount to a 4 "A6 x 4 "A6 x 2' /s -inch back box. The module shall also control two Style Y (class 8) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32 °F to 120 °F (0 °C to 49 °C) K Series Operating Temperature -40 °F to 151 °F ( -4TC to 66 °C) Humidity Range 10 to 93% non-condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR' Operating Voltage Range' 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8 diameter x 2.5" high (173 mm diameter x 64 mm high) Wall mount dimensions (including lens) 5.6"L x 4.7W x 2.5 (142 mm L x 119 mm W x 64 mm D) Horn dimensions 5.61 x 4.7 x 1.3 (142 mm L x 119 mm W x 33 mm D) Wall -mount back box skirt dimensions (BBS -2, BBSW -2) 5.91 x 5.OW x 2.2"D (151 mm L x 128 mm W x 56 mm D) Ceiling -mount back box skirt dimensions (BBSC -2, BBSCW -2) 7.1 diameter x 2.25 - high (180 mm diameter x 57 mm high) Wall -mount weatherproof back box dimensions (SA -WBB) 5.71 x S.1 V x ?.O (145 mm I_ x 130 mm W x 51 mm D) Ceiling -mount weatherproof back box dimensions (SA -WBBC) 7.1 "diameter x 2.0° high (180 mm diameter x 51 mm high) Notes: 1. Full Wave Rectified (FWR) voltage is a non - regulated, time varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AOS -0395 003 UL Current Draw Data DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 8 -17.5 Volts 288 16 -33 Volts Temporal Medium 209 224 8 -17.5 Volts 258 16 -33 Volts Candela DC FWR DC 221 FWR 256 Sound Pattern dB DC FWR DC FWR Standard 15* 123 128 66 299 71 219 Temporal High 57 55 291 69 75 Candela Range 15/75* 142 148 77 Candela Derating 81 Horn Tones and Sound Output Data Temporal Medium 44 49 84 58 69 30* NA NA ratings must be reduced in accordance with this table. 94 96 Temporal Low 38 44 44 48 75* NA NA Strobe Output 158 Switch 153 Non - temporal High 57 56 69 75 95* NA NA 181 176 Non - temporal Medium 42 50 60 69 110 NA NA 202 195 Non - temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150 NA NA 246 220 Coded Low 40 46 52 50 177 NA NA 281 251 185 UL Max. Current Draw (mA NA RMS), 2-wire NA Horn/Strobe, 286 Standard 258 Candela Range (115-11 S cd) 8 -17.5 Volts 16 -33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non - temporal High 141 152 91 100 116 176 201 221 229 Non - temporal Medium 133 145 75 85 102 163 187 207 216 Non - temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non - temporal High 142 161 103 112 126 181 203 221 229 Non - temporal Medium 134 155 85 95 110 166 189 208 216 Non - temporal Low UL Max. Current Draw (mA 132 RMS), 2-wire Horn/Strobe, 154 High 80 Candela Range 90 105 (135-185 cd) 161 184 202 211 16 -33 Volts 16 -33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non - temporal High 255 270 303 309 Non- temporal High 233 248 275 281 Non - temporal Medium 242 259 293 299 Non - temporal Medium 219 232 262 267 Non - temporal Low 238 254 291 295 Non - temporal Low 214 229 256 262 Candela Derating Low Horn Tones and Sound Output Data 75 81 For K series products used at low temperatures, listed candela 88 84 O utput 92 ratings must be reduced in accordance with this table. 8 -17.5 16 -33 24 Volt Nominal Strobe Output Switch Volts Volts Reverberant Anechoic Listed Candela Candela rating at -40 °F Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 15 Do not use below 32 °F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non - temporal High 82 82 88 88 93 92 100 100 5 Non - temporal Medium 78 78 85 85 90 90 98 98 6 Non - temporal Low 75 75 81 81 88 84 96 92 7' Coded High 82 82 88 88 93 92 101 101 8' Coded Medium 78 78 85 85 90 90 97 98 9' Coded Low 75 75 81 81 88 85 96 92 'Settings 7, 8, and 9 are not available on 2 -wire horn /strobe. A0: 0395.003 lert Advance Dimensions t 7.1" N-2.25' 1 5.05 - 12.23 Dia. I I p o I 000�o 5.98' O O Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Wall Horn /Strobes P2R *' 2 -wire Horn /Strobe, Standard cd', Red P2RH* 2 -wire Horn /Strobe, High cd, Red P2RK* 2 -wire Horn /Strobe, Standard cd, Red, Outdoor P2RHK* 2 -wire Horn /Strobe, High cd, Red, Outdoor P2W* 2 -wire Horn /Strobe, Standard cd, White P2WH* 2 -wire Horn /Strobe, High cd, White P4R* 4 -wire Horn /Strobe, Standard cd, Red P4RH* 4 -wire Horn /Strobe, High cd, Red P4RK 4 -wire Horn /Strobe, Standard cd, Red, Outdoor P4RHK 4 -wire Horn /Strobe, High cd, Red, Outdoor P4W* 4 -wire Horn /Strobe, Standard cd, White P4WH* 4 -wire Horn /Strobe, High cd, White Wall Strobes SCW *' SR *' Strobe, Standard cd, Red SRH *' Strobe, High cd, Red SRK Strobe, Standard cd, Red, Outdoor SRHK Strobe, High cd, Red, Outdoor SW* Strobe, Standard cd, White SWH* Strobe, High cd, White Ceiling Horn /Strobes PC2R* 2 -wire Horn /Strobe, Standard cd, Red PC2RH* 2 -wire Horn /Strobe, High cd, Red PC2RK 2 -wire Horn /Strobe, Standard cd, Red, Outdoor PC2RHK 2 -wire Horn /Strobe, High cd, Red, Outdoor Ceiling -mount horn /strobes / t 7.1' 2 D`ia. ® 5.7' o a O 0 0 �- 5.1 " Wall weatherproof back box Ceiling weatherproof back box Ceiling Horn /Strobes (contd.) PC2W *' 2 -wire Horn /Strobe, Standard cd, White PC2WH *' 2 -wire Horn /Strobe, High cd, White PC4R 4 -wire Horn /Strobe, Standard cd, Red PC4RH 4 -wire Horn /Strobe, High cd, Red PC4RK 4 -wire Horn /Strobe, Standard cd, Red, Outdoor PC4RHK 4 -wire Horn /Strobe, High cd, Red, Outdoor PC4W 4 -wire Horn /Strobe, Standard cd, White PC4WH 4 -wire Horn /Strobe, High cd, White Ceiling Strobes SCR* Strobe, Standard cd, Red SCRH* Strobe, High cd, Red SCRK Strobe, Standard cd, Red, Outdoor SCRHK Strobe, High cd, Red, Outdoor SCW *' Strobe, Standard cd, White SCWH *t Strobe, High cd, White Horns HR Horn, Red HRK Horn, Red, Outdoor HW Horn, White Accessories BBS -2 Back Box Skirt, Wall, Red BBSW -2 Back Box Skirt, Wall, White BBSC -2 Back Box Skirt, Ceiling, Red BBSCW -2 Back Box Skirt, Ceiling, White Notes: * Add' -P"to model number for plain housing (no "FIRE "marking on cover), e.g., P2R -P t Add " -SP "to model number for "FUEGO "marking on cover, e.g., P2R -SP t "Standard cd," refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd "refers to strobes that include 135,150, 177, and 185 candela settings. All outdoor units ending in "K" include a weatherproof back box. SYSTEM K"" SYst� semi. 3825 Ohio Avenue" St. Charles, IL 60174 Produccspe fc dt —^ .bjW tocha„gewth"mo ,%A� mmswcmfo, SENSOR' Phone :800- SENSOR2 "Fax:630- 377 -6495 °c "^omw o,m''^ ^' mewe, ormsntatn.� A05- 0395 - 003.12/06•/1676 4*� SYSTEM �A SENSOR Mini -Horns The SpectrAlert °Advance series of mini-horn sounders are designed to simplify installations to provide primary and secondary signaling for fire and security applications. o m S s e e S e n s o r Features The MHR and MHW mini -horns operate at 12 and 24 volts and are 12 and 24V operation ideal for hotel, motel or residential fire system applications, where a smaller notification device is desired.The mini -horns offer high High and low volume settings and low volume settings, and temporal or non - temporal tones. The • Temporal and non - temporal tones horns can be mounted to single gang back boxes for aesthetically Mounts to single gang back box sensitive applications. Synchronization is also provided when using the MDL module. Compatible with MDL sync module Mechanically and electrically compatible with PA400 series The MHR and MHW mini -horns can operate between 32 and 120 Mini - Alert - sounders degrees Fahrenheit from a regulated DC or full -wave rectified, unfiltered power supply. They are listed to Underwriter's Laboratories Standard UL 464 for fire protective signaling systerns. Agency Listings & LISTED <FM> APPROVED MEA approved SpectrAlert" Advance Mini -Horn Specifications Mini -horns shall be a System Sensor Model MHR or MHW capable of operating at nominal 12 or 24VDC and shall mount to a single gang back box. Mini - horn shall be listed to Underwriter's 1. aboratories Standard U1.464 for fire protective .signaling systems. Mini -horns shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full -wave rectified, unfiltered power supply. When used with the Sync-Circuit Module, 12 -volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 17 and 33 volts. Dimensions 4.61 x 2.9V x.45"D Weight 2.67 oz. Operating Temperature Range 32 °F to 120 °F (0 °C to 49 °C) Mounting Surface: single -gang back box Flush: 4" x 4" BBD deep back box (2 "deep) Electrical Specifications Input Terminals 12 to 18AWG Nominal Voltage Regulated 12DC/FWR or regulated 24DC/FWR Operating Voltage 8 -33 Operating Voltage with MOIL 9 -33 UL Sound Output and Current Draw Data Sounder Output (dBA) Switch Setting Pattern Output Level 8 -17.5 VDC 8 -17.5 VFWR Nominal 12 VDC Nominal 12 VFWR 16-33 VDC 16 -33 VFWR 1 Temporal High 68 67 71 70 78 76 2 Temporal Low 66 65 69 68 76 75 3 Non- temporal High 72 71 75 74 80 79 4 Non - temporal Low Sounder Current Draw (mA RMS) 70 69 73 72 78 77 Switch Position Sound Pattern 8 -17.5 Volts Volume DC FWR 16 -33 Volts DC FWR 1 Temporal High 12 10 17 15 2 Temporal Low 10 9 14 13 3 Non - temporal High 22 17 29 25 4 Non - temporal Low 17 13 21 19 Ordering Information Part No. De scription MHR Mini -Horn, Red MHW Mini -Horn, White <<� S 0'- 'Sy=,emse —, SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 Pd— pe fiw— ,.4 -t.0 ,� 0. 'A.csy�Wm�o� f., SENSOR Phone: 800- SENSOR2 • Fax: 630-377-6495 nos -oa " °""`wM °" �o a"° 14 o 0 • i "9`107`.1 743 d"" a a'"�` A05 0 ron • . va t Security Standard features - Expandable to 192 fully programmable hardwire and /or wireless zones 240 user codes • Up to 192 addressable devices can be used • 512 -event history log that provides date, time, event and user number • Up to 8 true partitions with separate account codes, entry /exit delays, and feature selections for each partition Maximum of 32 keypads with up to 8 per partition r Wireless technology with up to 192 supervised zones • 2 -wire or 4 -wire smoke detector compability * Fire alarm verification for greater false alarm immunity • Dynamic battery test Standard RS -232 on -board interface Overview The NetworX NX -8E is a full- featured security system that uses advanced technology for burglary, fire and environmental detection. The NX -8E is a flexible security system that is both easy to install and simple to use. With eight partitions and up to 192 zones, the NX -8E can handle your most demanding commercial and residential security needs. Outstanding features The NX -8E panel comes standard with eight hardwire zone inputs and two relays. Four programmable outputs can be set up to activate external devices during an alarm or other system event. The modular design allows for complete integration of multiple systems within one enclosure. Adding more zones or expanding capability is fast and easy. Convenient and flexible Conduct quick and easy on -site programming with alphanumeric keypads and a menu - driven text interface. off -site programming is also available with the DL -900 software for Windows. NetworX Control Panel NX -8E W'x M All Zones Secure R& __ — GY_ _Y a_ _.V . I " , • NetworX Security NetworX Control Panel NX -8E Specifications Operating Power - 16.5V AC 40VA Auxiliary w /40VA or 50VA transformer - 2 Amp s Auxiliary w /NX -320E power supply - 3 Amps* Loop resistance • For standard loop - 3000 Maximum For 2 -wire smokes - 3052 Maximum Operating temperature • 32 to 120OF Dimensions 6.40 inches wide 4.0 inches high * 1.10 inches deep Shipping weight 9 pounds When using the NX -320E W150VA transformer) rated of 2 Amps and NX -8E (w 140VA or 50VA transformer) rated of 1 Amp, the combined available power is 3 Amps. 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 USA & Canada: 800 -547 -2556 www.gesecurity.com r imagination at work Available Keypad Styles LED with LCD with Removable Door Removable Door Fixed Display with LED with Removable Door Removable Door Customer Service and Technical Support: 1- 888 -GE Security (437 -3287) (0 2005 GE Security. NetworX is a trademark of GE Security All other trademarks are properties of their owners. 466 - 2134- KA -010s www GE- Interl ogix. com PinPoint Addressable Point ID Systems Overview The PinPoint addressable solutions bring together NetworX NX -8E functionality with the reliability of GE Interlogix sensors. Supporting up to 792 devices on a single two -wire loop up to two miles, the PinPoint point ID solution can be installed fast in new construction or retrofit applications. Components 4 � ■ NetworX NX -8E Part # NX -8E PinPoint Interface Card Part # NX -2192E AP Series Motion Sensor Part # AP750 -ID Standard Features • Single two -wire loop up to two miles means fast and easy installation for new construction or retrofit applications • Addressable sensors indicates exact location of alarm or trouble event ShatterPro' o Supports up to 192 devices Glassbreak o Advanced digital communication from the sensors to Part # 5845 -ID the panel o GE Interlogix — a name you know and trust o Supports 3 Class 8 loops Single Input Device Part # Sl -ID 4 Input 4 Output Device Part # 4140 -ID AP750 -ID Addressable PIR Description Specifications An addressable PIR for use with the NX -2192E Pinpoint ID Bus Housing Material Flame retardant ABS Interface. Operating voltage 8 to 27V (as supplied by NX- 2192E) Current draw 250 pA typical avg. 3mA with LED momentarily on Features Transmit condition Alarm, tamper Detection range 50 ft (15.2m) Adaptive Single Processing - 3D signal processing with gliding Mounting height 6 to 10 ft (1.8 to 3m) focus mirror optics analyzes size, speed, shape and adaptive Number of curtains 7 alarm threshold. Operating temperature 32° to 131 °F (0° to 55 °C) Relative humidity 10% to 90% noncondensing Provides four separate curtain coverage patterns with 50' Maximum line length 10,000 ft (3km) (15.2 m) range. Dimensions Flat wall or corner mounting height up to 10'(3m), Width Depth 2.9' (74mm) 2.2' (56mm) Ships with two plastic inserts, each covering half the coverage Height 5.7' (129mm) pattern for more flexible mounting options (center curtain Listings UL 639, FCC always active). Coverage Patterns 50' 10, 3.Om � ' 45° Left J ,' m 45° Right 5845 -ID Addressable Shatterpro' Glassbreak Description An addressable ShatterPro ® ll glassbreak for use with the NX -2192E PinPoint ID Bus Interface. Features ShatterPro's Pattern Recognition Technology" for superior detection and false alarm immunity. Protects all glass types up to a standard thickness of 114" (6.4 mm) including plate, wired, tempered and laminated glass. Senses through light blinds and unlined drapes. Suitable for use in occupied areas on the perimeter loop. Specifications Housing material Operating voltage Current draw Microphone Operating temperature Relative humidity Maximum line length Dimensions Width Depth Height Listings Flame retardant ABS 8 to 27V (as supplied by NX 2192) 250 pA typical avg. 3mA with LED momentarily on Omni- directional electret 74' to 120°F (10 ° to 50 °C) 10% to 90% noncondensing 10,000 ft (3km) 3.13' (80mm) 1.7' (43mm) 4.2' (108mm) FCC SI-ID Single Input Device De Spec An addressable single input interface to connect a single Housing material Flame retardant ABS non - addressable device to the NX -2192E Pinpoint ID Operating voltage 8 to 27V (as supplied by NX- 2192E) bus interface. Signaling voltage 4 to 9V Current draw 250 pA Operating temperature 32° to 131 °F(0° to 55 °C) Features Relative humidity 10% to 90% noncondensing Maximum line length 10,000 It (3km) Supports a single non - addressable device. Dimensions Width 3.3' (84mm) Utilizes advanced digital data communications protocol that Depth 1.3' (33mm) ensures the integrity of the data communication. Height 28' (71mm) Listings UL 365, UL 609, UL 985, UL 1023, UL 1610, FCC Input Loop To single non - addressable (47k EOL included) From Pinpoint loop O device, such as a ma netic contact >1MS2 Open 47kt5% Single EOL 94kt5% Double EOL >200 Short 4140 -ID Four Input Four Output Device Description Spec An addressable 4 input and 4 unsupervised output interface that allows you to connect up to 4 non - addressable devices to the NX -2792E PinPoint ID Bus Interface. Features Supports four inputs and four unsupervised outputs (horns, bells, sirens, etc.). Utilizes advanced digital data communications protocol that ensures the integrity of the data communication. To unsupervised Addressable outputs, such as Inputs 0 0 0 horns and sirens O O O Housing material Operating voltage Signaling voltage Current draw Output current Operating temperature Relative Humidity Maximum line length Dimensions Width Depth Height Listings >1 MS2 47kt5% 94kt5% >200 Flame retardant ABS 12 to 30VDC 4to9V 100 pA (bus loading) 500mA maximum each 32° to 131 °F(0° to 55°C) 10% to 90% noncondensing 10, 000 It (3km) 6.8' (173mm) 2.0' (51mm) 4.8' (122mm) UL 365, UL 609, UL 985, UL 1023, UL 1610, FCC Open Single EOL Double EOL 0 hnrt NX -2192E Description Point ID Bus Interface Card. Features Attaches to the NX -8E control panel. Bus interface that supports up to 192 addressable devices on a two -mile loop. Supports three class 8 loops. Ordering Information Specifications Current Draw Operating temperature Shipping Weight Dimensions Width Depth Height NX -8E NetworX NX -8E control panel - NX -2192E PinPoint interface card - AP750 -ID Ge interlogix PIR White 5845 -ID Ge interlogix glassbreak White SI -ID Single input device White 4140 -ID 4 input 4 output device White 170 mA standby maximum 32° to 122 °F (0° to 50°C) 0.5 lb. 2' (51 mm) 1.25' (32mm) 9' (229mm) UL UL FCC UL GE Interlogix www.GE- Interlogix.com 12345 SW Leveton Drive 2266 Second Street North Tualatin, OR 97062 North St. Paul, MN 55109 Phone: 503-692-4052 Phone: 651- 777-2690 USA & Canada: 800- 547 -2556 USA & Canada: 800 - 777 -5484 Technical Service: 800 -648 -7424 Technical Service: 800.777 -2624 Faxback:800 -483 -2495 02003 GE Interlogix. Smoke! in a Can is a trademark of GE Interlogix. All trademarks are properties of their owners. M- 4301-XXXXKA -0103