HomeMy WebLinkAboutF11-0026TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970 - 479 -2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
SPRINKLER PERMIT Permit #
Job Address: 521 E LIONSHEAD CR VAIL Status ... :
Location.....: VAIL 21 CONDOMINIUMS - COMMON ELEMENT Applied .. :
Parcel No...: 210106403001 Issued . . .
Project No Expires. .:
OWNER SUSAN WONDRIES CATALANO
4612 VINETA AVE
LACANADA
CA 91011
APPLICANT ALLIANCE MECHANICAL
P.O. BOX 1855
EAGLE
CO 81631
License: 552 -S
CONTRACTOR ALLIANCE MECHANICAL
P.O. BOX 1855
EAGLE
CO 81631
License: 552 -S
TRUS 05/19/2011
F11 -0026
ISSUED
05/19/2011
05/19/2011
05/19/2011 Phone: 970 - 328 -0303
05/19/2011 Phone: 970 - 328 -0303
Desciption: COMMON ELEMENT: INSTALL PRESSURE REDUCING VALVES ON
EXISTING FIRE SYSTEM PER ERWSD
Valuation: $2,800.00
FEE SUMMARY ****##+ ff++#*#+**#+ rt####*# # * # * * # * * * # # * # # # # # # # + # # # # # # # #rt ##
Mechanical --- >
$0.00 Restuarant Plan Review - ->
$0.00 Total Calculated Fees --- >
$551.00
Plan Check --- >
$432.00 DRB Fee --------------------- >
$0.00 Additional Fees------ - - - - ->
($335.00)
Investigation ->
$0.00 TOTAL FEES--------- - - - - ->
$551.00 Total Permit Fee ---------- >
$216.00
Will Call - - - - ->
$0.00
Payments ------------------- >
$216.00
BALANCE DUE --------- >
$0.00
Item: 05100 BUILDING DEPARTMENT
Item: 05600 FIRE
DEPARTMENT
05/19/2011
mvaughan Action: AP
CONDITION OF APPROVAL
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 53
(FIRE 2007) Monitored fire sprinkler system required and shall comply with NFPA
13 (2007) and VFES Standards.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252
FROM 8:00 AM - 5 PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
FIRE SPRINKLER PERMIT
Commercial & Residential Fire Alarm shop drawings are required at the time of
application submittal and must include the following information:
1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp
2. Equipment cut sheets of materials
3. Hydraulic calculations
4. A State of Colorado Plan Registration form
5. Plans must be submitted by a Registered Fire Protection Contractor
Proiect Street Add_ ress:
-�1 a L) Slw�d C< r
(Number) (Street) (S
Office Use:
Project #: - �3 J''
Building Permit #:
Building/Complex Name: �
Sprinkler Permit #: t�-c�D
47G- / 3S v
Contractor Inf rrn n: Lot* Block # Subdivision:
Company:
k�C ^o
Company Address �_ Detailed Description of Work:
City: State Zip:
r
i Contact me: , �(T�c c�
r Contact Phone: f 7 [7 — ` -7 — 4L K,
1
E
Tctor Registration No.:
i
i
(required)
Property Information
Parcel #: _ � — o3 ()o I
(For parcel #, c ntact Eagle ounty Assessors Office at 970 - 328 -8640 or
visit www.eaglecounty.us /patie)
A i
Tenant Name:
'Owner Name:
Complete Valuation for Fire Sprinkler Permit:
i
(use additional sheet if necessary)
Detailed Location of Work X(/
n
Does a Fire Alarm Exist? Yes (6�- No( )
Does a Sprinkler System Exist? Yes (G) ( )
Work Class:
New ( ) Addition ( ) Remodel ( ) Repair
Retro-Fit ( Other ( )
Type of Building:
Single- Family ( ) Duplex ( ) Multi - Family (zT
Commercial (ke Restaurant ( ) Other ( )
Fire Sprinkler $: ! Date Received:
- ..._.............
-- -.... - - - -- 1
D [E C IE o W IF
MAY 12 2011
TOWN OF VAIL
ALLIANCE MECHANICAL INC.
P O BOX 1855
Eagle, Colorado. 81631
PH# 970.328.0303, FAX# 970.328.0378
Vail Fire Department 5/12/2011
42 West Meadow Dr
Vail, Co 81657
Phone: (970) 479 -2252
Project: Vail 21
Attention: Mike Vaughn - MVaughan @vailgov.com
Work on this project to include: fire system is 3 ", we will install a 4" Bermad 720
UL listed PRV at the beginning of the riser to meet the requirements of the
ERWSD. Going to a larger size is easier facilitated in to the piping & will not
lessen the hydraulic calculations of the existing system.
Sincerely,
�
Ron Aho President
Alliance Mechanical
Bermad Pressure Reducing Valve
Model: 720-UL
LISTED
INSTALLATION
OPERATION
MAINTENANCE
Application Engineering
BERMAD
appliceng@bermad.corrt vvvVwUe " x ^tTl s
%• .r x
The information contakiaQrri�Ybra to change without notke BERMAD shall n_otbsp h }�•
All Rights Reserved ®` '
� �,�� ..(. S .. !;.5. 5 ..x, �r i �•...
BE R MAD .
.
.. • 700 SENES
Technical Data
Th
R1
R2
R3
Th
t • •
* �CC - �l•1(O�
Valve Size
(1)Lyl
205 8
205
8
209 8'/4
250
9
�ax
320
12
415
16%
500
19 "A5
605
23
725
28•/w
733
28
990
1 39
• Max. for Class #150: 250 psi (17 bar)
(2)Ly2
155
l
155
616
212
8
250
9 "/,e
WA
WA
WA
WA
WA
WA
NIA
N/A
N/A
N/A
N/A
WA
N/A
WA
(3)Ly3
210
8
210
8
212
8
264
10
335
13'/4
433
17'/16
524
20
637
25
762
30
767
30
1024
40
(1)Lal
121
4a /.
121
4
140
512
152
6
190
7 1 /2
225
8
265
10
320
12
396
15
400
15
450
17
(2)La2
120
4
120
4
140
5' /2
159
6
WA
WA
WA
WA
WA
WA
N/A
N/A
N/A
N/A
N/A
WA
WA
WA
(3)La3
127
5
127
5
149
5
159
6
200
7 /e
234
9
277
10
336
13'/4
415
16
419
16%
467
18
(1)ht
82
3'/.
82
314
102
4
102
4
12 tN/ AN/A
2
8
203
8
219
8 5 /5
275
10
275
10
369
14' /2
H
(2)h2
82
31,
82
314
102
4
114
4'/2
W
WA
WA
WA
N/A
N/A
N/A
NIA
N/A
WA
WA
N/A
E (3)h3
89
3'12
89
3'/2
109
4
108
4'/4
13
6'/2
216
8
235
9'/_
294
11' /z
294
11'/2
386
5
i5
(1)Ri
75
21sns
83
31,4
93
3"
100
3,sne
110
512
171
63'4
203
8
241
91r2
267
10,n
298
11314
(2)R2
40
19`16
40
19ns
48
1711
55
21
N/
WA
WA
N/A
N/A
N/A
N/A
N/A
N/A
WA
WA
WA
(3)R3
78
3v16
83
3va
95
344
108
4v4
129
61/A191
712
222
8y4
260
101u
292
111/2
324
12y
91
7'12
191
7 1 /2
191
7' /z
207
8' /,e
240
11
325
12
370
14'/,6
515
20'/4
525
20
610
24
Th
312
12
312
12
312
12
364
14
405
20
568
22
639
25
449
17 " /6;
449
17 "/
541
21
Notes:
1. Lyt, Lat & ht for flanged ANSI #150 and ISO PN16.
4. Data is for maximum envelope dimensions, component positioning may vary.
2. Ly2, Lag & h2 for threaded female, NPT or BSP.
5. Provide adequate space around valve for maintenance.
3. Ly3, La3 & h3 for flanged ANSI #300 and ISO PN25.
Connection Standard
Sizes ( "Y" & Angle)
Pressure Rating
• Flanged: ANSI 816.42 (Ductile Iron),
• Available Y: 1 /2 - 20"
• UL- Listed 2 - 6 ": 300 psi (21 bar)
816.5 (Steel & Stainless Steel),
• Angle: 1 — 18"
8" to: 175 psi (12 bar)
616.24 (Bronze), ISO PN16
24 -36 Globe
• Max. for Class #150: 250 psi (17 bar)
• Threaded: NPT or BSP 2, 2 & 3"
• UL- Listed: 2, 2 3, 4, 6 & 8"
• Max. for Class #300:400 psi (28 bar)
Water Temperature
• Setting range: 30 - 165 psi (2 - 11.5 bar)
• 0.5 - 80 °C (33 - 180 °F)
• Test pressure: 450 psi (31 bar)
Manufacturers Standard Materials
Main valve body and cover
• Ductile Iron ASTM A -536
Main valve internals
• Stainless Steel & Elastomer
Control Trim System
• Brass control components/accessories
• Stainless Steel 316 tubing & fittings
Elastomers
• Polyamide fabric reinforced Polyisoprene, NR
Coating
• Electrostatic Powder Coating Polyester,
Red (RAL 3002)
Optional Materials
Main valve body /internals
• Carbon Steel ASTM A- 216 -WCB
• Stainless Steel 316
• Ni- AI- Bronze ASTM B -148
• Titanium
• Duplex
• Hastalloy
Control Trim
• Stainless Steel 316
• Monel@ and AI- Bronze
• Hastalloy C -276
Coating
• High Built Epoxy Fusion - Bonded
with UV Protection, Anti - Corrosion
Approvals
• UL Listed for:
Special system water control
valves (VLMT), Pressure Reducing
and Pressure Control type
for Fire Protection Systems.
• ABS
• Lloyd's Registered
e . 1 ut ww'berma;Ypm'
bermadfi�,e@bE d c om • ,
The info
1 �'Q wlthout notice BERMAD shall not b4
any erro $
tlttl Ql91af1 __ 1 ... ` * t
BERN EY Fi
1. Safety First
BERMAD believes that the safety of personnel working with and around our equipment is the most important
consideration. Please read all safety information below and from any other relevant source before attempting to
perform any maintenance function.
Comply with all approved and established precautions for working with your type of equipment and /or environment.
Authorized personnel should perform all maintenance tasks.
Prior to performing a procedure, read it through to the end and understand it. If anything is not clear, ask the
appropriate authority.
When performing a procedure, follow the steps in succession without omission"
Description
BERMAD's Model 720UL Pressure - Reducing Valve is an automatic pressure control valve that reduces higher inlet
pressure to lower constant outlet pressure, regardless of fluctuating flow -rates and /or varying inlet pressure. It is a
pilot- operated, diaphragm- actuated, low pressure -loss valve. Valve differential pressure powers the diaphragm
actuator open or closed. The double- chambered actuator design enables quick and smooth valve action
Models and Sizes
Models and Sizes covered by this document include the BERMAD Pressure - Reducing Valve 720UL, sizes 2 ", 2.5 ",
3 ", 4 ", 6" and 8 ". It is available in either the Globe "Y" or Angle pattern.
Operating Pressure Rating
Sizes 2 ", 2.5 ", 3 ", 4" and 6" have a maximum rated inlet pressure of 300 psi (21 bar).
Size "8" have a maximum rated inlet pressure of 175 psi. (12 bar).
Outlet pressure setting for all sizes is 30-165 psi.
When setting the outlet pressure, the inlet pressure should be at least 15 psi (1 bar) higher than the set outlet
pressure.
In cases where the inlet pressure falls below or is equal to the intended outlet pressure, the outlet pressure and
flow will be as described in Tables 2 through 7.
In the case of zero (static) flow through the valve, the maximum increase in the downstream (outlet) pressure
above the set pressure of the valve will not exceed 8 psi (0.5 bar).
Flow Capacity Table
Valve Size [in (mm)]
2 (50)
3 (80)
4 (100)
6 (150)
8 (200)
2.5(65)
Max. Inlet pressure
175 000
175 000
175 &300
175 &300
175
[psi (bar)]
(12 &21)
(12&21)
(12&21)
(12 &21)
(12)
Outlet pressure adjustable range
30 -165
30 -165
30 -165
30 -165
30 -165
[psi (bar)]
(2 -11.5)
(2 -11.5)
(2 -12)
(2 -11.5)
(2 -11.5)
Maximum flow -rate
150
500
800
1800
4000
[GPM (LPM)]
(568)
(1892)
(3028)
(6813)
(15140)
Minimum required flow -rate for
75
250
400
900
2000
Pilot Setting [GPM (LPM)]"'
(284)
(946)
(1514)
(3406)
(7570)
Table 1
'Required flows to be established through the valve to properly adjust the set pressure.
app)iceng @bermad.00m 0 www berrnad c� ,. j r Pi7PE04 -720 -Uri
The information cont"' '�3j etiang wi
e thout notice e M
ERAD shal � V bontained herein
All Rights Reserved
3. UL Listed
BERMAD 720 -UL Deluge Valve is UL Listed when installed with specific components & accessories. Refer to the
current UL Directory. Consult the manufacturer for any component approval recently to appear in the UL fire
protection equipment directory.
4. Installation
4.1 Allow enough room around the valve assembly for any adjustments and future maintenance /disassembly
work.
4.2 Before the valve is installed, flush the pipeline to remove any dirt, scale, debris, etc. Failure to do this might
result in the valve being inoperable.
4.3 Listed indicating valves should be installed upstream and downstream of the BERMAD Model 720UL valve to
allow future maintenance. See figure 1.
4.4 Install the valve in the pipeline with the valve flow arrow on the body casting in the proper direction. Use the
lifting eye provided on the main valve cover for lifting and lowering the valve.
4.5 The Model 720UL is intended for horizontal installation only. Ensure that the valve is positioned so that the
actuator can be easily removed for future maintenance.
4.6 After installation, carefully inspect/correct any damaged accessories, piping, tubing, or fittings.
4.7 Install a UL listed sprinkler system pressure relief valve sized in accordance with NFPA 13.
4.8 Install a UL listed pressure gauge on both the upstream & downstream of the Pressure Reducing Control Valve.
See installation drawing, figure 1, for indicated installation.
4.9 Install the Model 720UL valve in accordance with the Standard for Installation of Fire Sprinkler Systems, NFPA
13, or the Standard for Installation of Standpipe and Hose Systems, NFPA 14, as appropriate. The Model
720UL valve is to be tested after installation in accordance with NFPA 13.
4.10 The Model 720UL valve is to be inspected, tested and maintained in accordance with the Standard for the
Inspection, Testing and Maintenance of Water -Based Fire Protection Systems, NFPA 25.
appliceng @bermad
All Rights
c : fiYo��2o -
- rfained herein