HomeMy WebLinkAboutBillings, Art 3F � � . s s� .
v � � �
F �:; .
AA1311AWS D1 . 1 /D1 . 1M : 20a8 - WELDER AND WELDING QPERATOR OR TP.CI� WELDER QUALIFICATIqN TEST RECt}RD
Type of Welder TACR WELDER
Name ART BILLINGS Stamp No . B64
Welding Procedure Specification No ( s ) . PSI - i20 Rev . N /A Date N /A
Record Actual Values
Variables Used in Qualification Qualificatioa Range
Process / Type [ 4 . 12 , Item ( 1 ) ] 5MAW-MA
Electrode � SjTjlg ,_ �ltiPle} tx�le 4 . 1z , =t�� � � l Sin le Sin le
Current / Polarity DC / Electrode Positive
Position [ Table 4 . 12 , Item ( 4 ) ] 3F VeIt1Ca1 1F-2F-3F See 4.19.2.1 Other Joints
Weld Progression [ Table 4 . 12 , Item ( 5 ) � U ward U ward
Backittg ( Y8S or NO ) [ Table 4 . 12 , Item ( 6 ) ] NO N /A N /A
Material /Spec . ASTM A-36 to ASTM A-36 Grou I II
Base Metal
Thicknessz ( Plate )
Groove N/A 1 / 8 " throu h unlimited
Fillet 3 / 8 " 1 / 8 " throu h unlimited
Thickness : ( Pipe /Tube )
Groove N/A N /A
Fillet 13 /A 1 / 8 " throu h unlimited
Diameter : ( Pipe )
Groove N/A N/A
Fillet NIA ALL
Filler Metal ( Table 4 . 12 ]
Specification No . A5 . 1
Classification E7Q18
F-No . [ Table 4 . 12 , Item ( 2 ) ] 4 F-No . 1 2 3 & 4
Gas / Flux Type [ Table 4 . 12 ] N/A N/A
Ot$er N /A N/A
SB = SIDE BEND VISUAL INSPECTIOIt ( 4 . 8 . 1 )
FB = FACE BEND Acceptable YES or NO ( 3F ) YES
RB = ROQT BEND Guided Bend Test Results ( 4 . 30 . 5 ) N /A
POSITIONs 3G VERTICAL UP 4G OVERHEAD
TYPE RE5ULT TYPE RESULT
FB # 1 : NIA N A
RB # l :
C = Crack(s}, M = Micm <1/64", CC = Corner Crack, M = No Indications , UC = Undercnt (51/32" depth) MSR = Meets Specificahon Reqoaements
P = Pore/ Porosity (dia) NMSR = Dces NOT Meet Specification RequiremenE
Fillet Test Results ( 4 . 30 . 2 . 3 and 4 . 30 . 4 . 1 - Tack Welder 4 . 31 & 4 . 19 . 2 )
Appearance : Acceptable ------------ ---- MSR Fillet Size : 1 / 4 "
Fracture Test Root Penetration : Folded on self root exposed & Acceptable Macroetch : N /A
( Describe the location , nature , and si.ze of any crack or tearing of the speci.men . )
Welding Test conducted by: Patrick Mulvilte, CWI, CWE Date: 06/15/2009 LocatiOri: Pioneer Steel-Job Site, Evans Hosnital Ft Cazson CO 80913
Mechanical Test conducted by and Inspected by : Patrick T . MulV7. 11e , CWI , CWE LABORATORY TEST NO . : 1408
Organization : Mulville ' s G7eldinq Inspection & Code Consultinq TEST COMPLETION DATE : 06 / 15 / 2Q09
N /A RADIOGRAPHYC TEST RESULTS ( 4 . 3 � . 3 . 2 )
Identification Results Remarks Identification Results Remark
Interpreted by : N /A Test Number N /A
Organi. zation : N /A Date N /A
We, the undersigned, csrtify that the statements in this record are correct and that the welds were prep ared, welded anc
tested in conformance with the requirements of section 4 of ANSI/AWS D1 . 1/D1 . 1M:(2008) Structural Welding Code-S�teel.
orgau;zation: Pioneer Steel, I�c , 3$246 River Frant��e Rd �New Castle, C4 81647 - 970-9849229
Authorized by: Gerald Burk, President, Projeet Mana�er Date: 06i1512009
By: ��ezivatie's �Veldin�; Inspestioa� and CocEe Cansuitite� Date: 06/20/2009 ��g�re)
PA�iC�T. MU6.�lL�