HomeMy WebLinkAboutKelly, Chris 3 G 4G THUNDER MOUNTAIN TESTIl'�TG
♦ ♦ ♦
2973 F. Road ♦ Grand Junction, CO 81504
(970) 256-9965 / Cell (970) 210-7008 / FAX (970) 314-7067
PIONEER STEEL INC . Page 1 of 1
Welder Qualification Test Record CHRIS K 7 -PSI
WQTR No. CHRIS K 1 -PSI Welder Name CHRIS KELLY Welder ld
WPS No. PSI-B-U2a Revision 0 Date 2/15/2008
Variables Record Actual Values Used In Qualification Qualification Range
Process (Table 4. 10, Item (1 )) SMAW SMAW
Transfer Mode (GMAW): Short-Cir. ❑ Globular ❑ Spray ❑ Short-Circuiting ❑ Globular ❑ Spray ❑
Type Manual � Machine ❑ Semi Auto ❑ Auto ❑ Manual � Machine ❑ Semi Auto ❑ Auto ❑
Number of Electrodes Single � Multiple ❑ Single � Multiple ❑
CurrenUPolarity AC ❑ DCEP � DCEN ❑ Pulsed ❑ AC ❑ DCEP � DCEN ❑ Pulsed ❑
Position (Table 4. 10, Item (4)) 3G. 4G 1 G. 2G. 3G. 4G, 7 F. 2F. 3F. 4F
Weld Progression: (Table 4. 10, Item (6)) Up � Down ❑ Up � Down ❑
Backing [Table 4. 10, Item (7)] Use Backing � With Backing � Without Backing ❑
Consumable Insert (GTAW) Use Insert O With Insert ❑ Without Insert ❑
Material/Spec. A36 to A36 All Group 1 8� II MaYI
Thickness (Plate): Groove ( in ) .375 .125 - .75 in
Fillet ( ) .125 - Unlimited in
Thickness (Pipe/tube): Groove ( ) .125 - .75 in
Fillet ( ) .125 - Unlimited in
Diameter(Pipe): Groove ( ) > 24 OD - in
Fillet ( ) > 24 OD - in
Notes ` Qualifies to Backqouge
Filler Metal (Table 10, Item (2))
Spec. A5.1 A5.1 , A5.5
Class. E7018 E70XX and Lower Strenqth Electrodes
F-No. 4 F4 and Lower
Gas/Flux Type (Table 4. 10, Item (3))
Other 1 /8" Electrode 5/32" and Lower
VISUAL INSPECTION (4.8.1 ) Acceptable Yes
GUIDED BEND TEST RESULTS (4.30.5)
Type Result Type Result
3G - Face Acceptable 3G - Root Acceptable
4G - Face Acceptable 4G - Root Acceptable
Fillet Test Results (4.302.3 and 4.30.4. 1 )
Appearance Fillet Size Macroetch
Fracture Test Root Penetration Description
Inspected By SCOTT L. MAXWELL / AWS CWlest No. 08-61 OrganizafionTHUNDER MOUNTAIN T N TJ15/2008
RADIOGRAPHIC TEST RESULTS (4.30.3. 1 ) � �� �
Film Identification No. Re ult Remark
Interpreted By� SG
Organization U4
Test No.
Date
We, the undersigned, certify that the statements in this record are corzect and that the test welds were prepared, welded, and
tested in accordance with the requirements of section 4 of ANSI/AWS D1 . 1 , ( 2006 ) Structural Welding Code-Steel.
Manufacturer PIONEER STEEL INC. Authorized By DON BOUSMAN Date 2/75/2008