HomeMy WebLinkAboutMontalbano, A 4G THUNDER MOUNTAIN TESTING
♦ ♦ ♦
2973 F. Road ♦ Grand Junction, CO 81504
(970) 256-9965 / Celi (970) 210-7008 / FAX (970) 314-7067
PIONEER STEEL INC . Page 1 of 1
Welder Qualification Test Record ANTHONY M 1 -PSI
WQTR No. ANTHONY M 1 -PSI Welder Name ANTHONY MONTALBANO Welde� id
WPS No. PSI-B-U2a Revision 0 Date 3/7/2008
Variables Record Actual Values Used In Qualif'ication Qualification Range
Process (Table 4. 10, Item (1 }) SMAW SMAW
Transfer Mode (GMAW): Short-Cir. ❑ Globular ❑ Spray ❑ Short-Circuiting ❑ Globular ❑ Spray ❑
Type Manual � Machine ❑ Semi-Auto ❑ Auto ❑ Manual � Machine ❑ Semi Auto ❑ Auto ❑
Number of Electrodes Single � Multiple ❑ Single � Multiple ❑
CurrenUPolarity AC ❑ DCEP � DCEN ❑ Pulsed � AC ❑ DCEP � DCEN ❑ Pulsed ❑
Position (Table 4. 10, Item (4)) 4G 1G. 4G. 1F. 2F. 4F
Weld Progression: (Table 4.10, Item (6)) Up ❑ Down ❑ Up ❑ Down ❑
Backing [Table 4. 10, Item (7)] Use Backing � Witfi Badcing � Without Backing ❑
Consumable Insert (GTAW) Use Insert ❑ With Insert ❑ Without Insert ❑
Material/Spec. A36 to A36 All Group 18� II MaYI
Thickness (Plate): Groove ( in ) .375 .125 - .75 in
Fillet ( ) .125 - Unlimited in
Thickness (Pipe/tube): Groove ( ) .125 - .75 in
Fillet ( ) .125 - Unlim'rted in
Diameter(Pipe): Groove ( ) > 24 OD - in
Fillet ( ) > 24 OD - in
Notes " Qualifies to Backqouge
Filler Metal (Table 10, Item (2))
Spec. A5.1 A5.1 , A5.5
Class. E7018 E70XX and Lower Strenqth Electrodes
F-No. 4 F4 and Lower
Gas/Flux Type (Table 4. 10, Item (3))
Other 1/8" Electrode 5/32" and Lower
VISUAL INSPECTION (4.8.1 ) Acceptable Yes
GUIDED BEND TEST RESULTS (4.30_5)
Type Result Type Result
4G - Face Acceptable 4G - Root Acceptable
Fillet Test Resutts (4.30.2.3 and 4.30.4. 1 )
Appearance Fillet Size Macrcetch
Fracture Test Root Penetration Description
Inspected By SCOTT L. M ELL / AWS CWlest No. 08-87 OrganizationTHUNDER MOUNTAIN TESTING 3RI2008
RADIOGRAPHIC TEST RESULTS (4.30.3.1 )
Film Identification No. esult Remark QC �
Interpreted By
Organization ` S �. n� �
Test No. 91d4 r
Date � "
We, the undersigned, certify that the statemenis in ihis record are correct and that the test welds were prepared, , and
tested in accordance with the requirements of section 4 ofANSI/AWS D1 . 1 , ( 2006 ) Structural Welding CodetiSteel.
Manufacturer PIONEER STEEL INC. Authorized By DON BOUSMAN Date 3/7/2008 �
�