HomeMy WebLinkAboutStreet, J D1.5 3G ; WELDER QUALIFICATION TEST REPORT (WQTR) � AWS D 1 . 5- Bridge Welding Code WQTR No. : PSI-521 JS 3G Welder Name: Jared Street Welder ID : JS WPS No . : PSI-521 Welder Type: SMAW Rev Orig Date: 1 /28/10 Pro'ect Number: 2010007 Record Actual Values Qualification Range Used in Qualification Variables Process/Type SMAW SMAW Electrode (single or multiple) Sin le Sin le Current/Polarity DCEP DCEP Position 3G Groove: Vertical , Horizontal , Flat Fillet: Vertical , Horizontal , Flat Weld Progression Vertical U Vertical U Backing or back weld : Yes Backin on Groove welds Material/Spec. M270M Gr 250 36 M270M Gr 250 (36 or Gr 345 50 Base Metal M270M Gr 250 36 M270M Gr 250 36 or Gr 345 50 Thickness: (Plate) Groove 1 .000" 0 . 125" to Unlimited Fillet -- 0. 125" to Unlimited Filler Metal -- __ Spec. No. A 5. 1 A 5 . 1 Class E7018 E7018 F-No. 4 q Gas/Flux Type n/a n/a Diameter 1 /8" 3/32" to 5/32" A `*� VISUAL INSPECTION — Accept �F$f 1 +° Guided Bend Test Results � T e Result T e Result Side 1 Acce t Side 2 Acce t / Side 3 Acce t Side 4 Acce t Inspected by: Jesse A. Grantham , AWS-CWI #98041061 Test Number: 2010007 Organization: Welding & Joining Mgmt Group, West Date: 1 /28/10 RADIOGRAPHIC TEST RESULTS Film Identification Results Remarks Film Identification Results Remarks Number Number N/A N/A Interpreted by: n/a Test Number: n/a Organization : n/a Date: n/a We, the undersigned , certify that the statements in this record are correct and that the test welds were prepared , welded, and tested in accordance with the requirements of AASHTO/AWS D1 .5M/D1 .5 Bridge Welding Code. Company: Pioneer Steel Inc. Authorized By: Mr. Gerald Burk 38426 River Frontage Road ♦ New Castle , CO 81647