Loading...
HomeMy WebLinkAbout05 SFRM 110331 C RDU�1In ENGINEERING CONSULTRNTS FIREPROOFING DATA SHEET Project First Chair Employee Housing Date August 9, 2010 Job Number 10-6522 Reported to Vail Resorts Development Co. Copies to PO Box 959 Avon, CO 81620 Attn: Mr. Kyle Griffith Beams Test number 1 THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION Location: Level 2 Gridlines B.5/1.8 Location: Level 2 Gridlines B.5/1.8 � � � � � � � �9 ThiCkness #1 inches ThiCkness #2 inches 2 - --$ AT EACH END OF Thickness #3 II7Ches 12-INCH LENGTH Thickness #4 inches 3— —� ThiCkness #5 inches 4 � ��� � �� Thickness #6 incnes � ThiCkness #7 inches ThiCkness #8 inches Test Number: Test Number: Thickness #9 incnes 1.� 13/16 1.� 14/16 ThiCkness #10 inches 2.) 1 2.) 14/16 Thickness #11 inches 3.) 14/16 3.) 1 ThiCkness #12 inches *4.) 14/16 *4.) 13/16 Volume of test area: #DIV/0! cubic feet 5.) 11/16 5.) 10/16 Length of test area: inches *6.) 13/16 *6.) 13/16 Width of test area: inches 7.) 13/16 7.) 14/16 Average thickness: #DIV/0! inches 8.� 14/16 $.� 1 DENSITY DETERMINATION 9.) � 9.) � Weight of pan (g) Weight of pan and material (g) Weight of material (Ibs) 0 excluding Average Thickness (inches) flangetips 14/16 Density (pcf) Average Thickness (inches) flangetips 11/16 Specified Thickness (inches)min. 13/16 Specified density (pcf)min. ADHESION DETERMINATION Diameter of specimen: inches Location: Level 2 Gridlines B.5/1.8 Area of specimen: 0 sq.ft. Recorded force: Ibs. Adhesion (psf� Specified adhesion (psf� min. 7/16 minimum Flange Tips Field Representative: Kevin McClure C RDU�1In ENGINEERING CONSULTRNTS FIREPROOFING DATA SHEET Project First Chair Employee Housing Date August 12, 2010 Job Number 10-6522 Reported to Vail Resorts Development Co. Copies to PO Box 959 Avon, CO 81620 Attn: Mr. Kyle Griffith Beams Test number 2 THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION Location: Level 2 Gridlines H.0/5.8 Location: Level 2 Gridlines H.0/5.8 � � � � � � �9 Thickness #1 incnes ThiCkness #2 inches 2 - --$ AT EACH END OF Thickness #3 II7Ches 12-INCH LENGTH Thickness #4 inches 3— —� ThiCkness #5 inches 4 � ��� � �� Thickness #6 incnes � ThiCkness #7 inches ThiCkness #8 inches Test Number: Test Number: Thickness #9 incnes 1.) 10/16 1.) 10/16 Thickness #10 inches 2.) 15/16 2.) 13/16 Thickness #11 inches 3.) 9/16 3.) 10/16 Thickness #12 inches *4.) 9/16 *4.) 10/16 Volume of test area: #DIV/0! cubic feet 5.) 14/16 5.) 15/16 Length of test area: inches *6.) 10/16 *6.) 9/16 Width of test area: inches 7.) 10/16 7.) 9/16 Average thickness: #DIV/0! inches 8.� 9/16 $.� 9/16 DENSITY DETERMINATION 9.) 14/16 9.) 13/16 Weight of pan (g) Weight of pan and material (g) Weight of material (Ibs) 0 Density (pcf) Average Thickness (inches) flangetips 10/16 #DIV/0! Specified Thickness (inches)min. 13/16 Specified density (pcf)min. ADHESION DETERMINATION Diameter of specimen: inches Location: Level 2 Gridlines H.0/5.8 Area of specimen: 0 sq.ft. Recorded force: Ibs. Adhesion (psf� Specified adhesion (psf� min. Flange Tips minimum 7/16 Field Representative: Kevin McClure C RDU�1In ENGINEERING CONSULTRNTS FIREPROOFING DATA SHEET Project First Chair Employee Housing Date August 20, 2010 Job Number 10-6522 Reported to Vail Resorts Development Co. Copies to PO Box 959 Avon, CO 81620 Attn: Mr. Kyle Griffith Beams Test number 2.1 THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION Location: Level 2 Gridlines H.0/5.8 Location: Level 2 Gridlines H.0/5.8 � � � � � � �9 Thickness #1 incnes ThiCkness #2 inches 2 - --$ AT EACH END OF Thickness #3 II7Ches 12-INCH LENGTH Thickness #4 inches 3— —� ThiCkness #5 inches 4 � ��� � �� Thickness #6 incnes � ThiCkness #7 inches ThiCkness #8 inches Test Number: Test Number: Thickness #9 incnes 1.� 12/16 1.� 12/16 ThiCkness #10 inches 2.) 1 2.) 13/16 Thickness #11 inches 3.) 14/16 3.) 1 ThiCkness #12 inches *4.) 11/16 *4.) 12/16 Volume of test area: cubic feet 5.) 15/16 5.) 1 Length of test area: inches *6.) 10/16 *6.) 12/16 Width of test area: inches 7.) 11/16 7.) 1 Average thickness: inches 8.� 15/16 $.� 15/16 DENSITY DETERMINATION 9.� 13/16 9.� 14/16 Weight of pan (g) Weight of pan and material (g) Weight of material (grams) 18.00 excluding Average Thickness (inches) flangetips 14/16 Density (pc� � 24.0 Average Thickness (inches) flangetips 9/16 Specified Thickness (inches)min. 13/16 Specified density (pcf)min. 19 ADHESION DETERMINATION Diameter of specimen: 3.25 inches Location: Level 2 Gridlines H.0/5.8 Area of specimen: 0.0576 sq.ft. Recorded force: 29 Ibs. Adhesion (psf) 503 Specified adhesion (psf) min. 500 7/16 minimum Flange Tips. Adhesion test performed on 8/20/2010. Field Representative: Kevin McClure �RVir�n ENGINEERING C�NSULTRNTS FIREPROOFING DATA SHEET Project First Chair Employee Housing Date 8/9/2011 Job Number 10-6522 Reported to Vail Resorts Development Co. Copies to PO Box 959 Avon, CO 81620 Attn: Mr. Kyle Griffith Tube Columns Test number 1 THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION Location: Level 2 Gridline A.7/5.4 Location Level 2 Gridline A.7/5.4 � 4 MEASUREMENTS � Thickness #1 117Ch2S AT EACH END OF Thickness #2 inches � 12-INCH LENGTH �, '��. /�� Thickness #3 inches 2 4 2 4 Thickness #4 inches ��`- � �� Thickness #5 inches 3, 3� Thickness #6 inches Thickness #7 inches Thickness #8 inches Test Number: Test Number: Thickness #9 inches 1.� 1 7/16 1.� 1 7/16 Thickness #10 inches 2.� 1 9/16 2.� 1 9/16 Thickness #11 inches 3.� 1 7/16 3.� 1 7/16 Thickness #12 inches 4.) 1 10/16 4.) 1 9/16 Volume of test area: cubic feet Length of test area: inches Width of test area: inches Average thickness: inches DENSITY DETERMINATION Weight of pan (g) Weight of pan and material (g) Weight of material (Ibs) Average Thickness (inches) 1 8/16 Density (pc� Specified Thickness (inches) min. 1 12/16 Specified density (pc� min. ADHESION DETERMINATION Diameter of specimen: inches Location: Area of specimen: 0 sq.ft. Recorded force: Ibs. Adhesion (pst� Specified adhesion (psf� min. Notes: Field Representative: Kevin McClure CRDUKn ENGINEERING CDNSULTRNTS FIREPROOFING DATA SHEET Project First Chair Employee Housing Date 8/12/2010 Job Number 10-6522 Reported to Vail Resorts Development Co. Copies to PO Box 959 Avon, CO 81620 Attn: Mr. Kyle Griffith Tube Columns Test number 1.1 THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION Location: Level 2 Gridline A.7/5.4 Location Level 2 Gridline A.7/5.4 � 4 MEASUREMENTS � Thickness #1 II7CheS ; AT EACH END OF + Thickness #2 inches 12-INCH LENGTH /� � Thickness #3 inches z 4 Z 4 Thickness #4 inches Thickness #5 inches � 3f Thickness #6 inches Thickness #7 inches Thickness #8 inches Test Number: Test Number: Thickness #9 inches 1.) 2 4/16 1.) 2 2/16 Thickness #10 inches 2.) 2 1/16 2.) 2 Thickness #11 inches 3.� 1 13/16 3.� 1 13/16 ThiCkness #12 inches 4.) 1 15/16 4.) 2 Volume of test area: cubic feet Length of test area: inches Width of test area: inches Average thickness: inches DENSITY DETERMINATION Weight of pan (g) Weight of pan and material (g) Weight of material (grams) 25.4 Average Thickness (inches) � 2 Density (pcf) � 24.0 Specified Thickness (inches)min. 1 3/4 Specified density (pcf) min. 15 ADHESION DETERMINATION Diameter of specimen: 3.25 inches Location: Area of specimen: 0.057609 sq.ft. Recorded force: 24 /bs. Adhesion (psf) 417 Specified adhesion (psf) min. 200 Notes: Adhesion test performed on 8/20/2010. Field Representative: Kevin McClure �RVir�n ENGINEERING C�NSULTRNTS FIREPROOFING DATA SHEET Project First Chair Employee Housing Date 8/9/2011 Job Number 10-6522 Reported to Vail Development Co. Copies to PO Box 959 Avon, CO 81620 Attn: Mr. Kyle Griffiths Tube Columns Test number 2 THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION Location: Level 2 Gridline A.0/5.4 Location Level 2 Gridline A.0/5.4 � 4 MEASUREMENTS � Thickness #1 117Ch2S AT EACH END OF Thickness #2 inches � 12-INCH LENGTH �, '��. /�� Thickness #3 inches 2 4 2 4 Thickness #4 inches ��`- � �� Thickness #5 inches 3, 3� Thickness #6 inches Thickness #7 inches Thickness #8 inches Test Number: Test Number: Thickness #9 inches 1.� 1 7/16 1.� 1 7/16 Thickness #10 inches 2.� 1 10/16 2.� 1 8/16 Thickness #11 inches 3.� 1 7/16 3.� 1 6/16 Thickness #12 inches 4.) 1 6/16 4.) 1 7/16 Volume of test area: cubic feet Length of test area: inches Width of test area: inches Average thickness: inches DENSITY DETERMINATION Weight of pan (g) Weight of pan and material (g) Weight of material (Ibs) 0.0000 Average Thickness (inches) 1 7/16 Density (pc� Specified Thickness (inches) min. 1 1/4 Specified density (pc� min. ADHESION DETERMINATION Diameter of specimen: inches Location: Area of specimen: 0 sq.ft. Recorded force: Ibs. Adhesion (pst� Specified adhesion (psf� min. Notes: Field Representative: Kevin McClure �RVir�n ENGINEERING C�NSULTRNTS FIREPROOFING DATA SHEET Project First Chair Employee Housing Date 8/9/2010 Job Number 10-6522 Reported to Vail Resorts Development Co. Copies to PO Box 959 Avon, CO 81620 Attn: Mr. Kyle Griffith Tube Columns Test number 3 THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION Location: Level 2 Gridline A.0/4.6 Location Level 2 Gridline A.0/4.6 � 4 MEASUREMENTS � Thickness #1 117Ch2S AT EACH END OF Thickness #2 inches � 12-INCH LENGTH �, '��. /�� Thickness #3 inches 2 4 2 4 Thickness #4 inches ��`- � �� Thickness #5 inches 3, 3� Thickness #6 inches Thickness #7 inches Thickness #8 inches Test Number: Test Number: Thickness #9 inches 1.) 1 1.) 1 1/8 Thickness #10 inches 2.� 1 3/16 2.� 1 3/16 Thickness #11 inches 3.) 1 1/2 3.) 1 3/8 Thickness #12 inches 4.) 1 1/2 4.) 1 1/2 Volume of test area: cubic feet Length of test area: inches Width of test area: inches Average thickness: inches DENSITY DETERMINATION Weight of pan (g) Weight of pan and material (g) Weight of material (Ibs) 0.0000 Average Thickness (inches) 1 5/16 Density (pc� Specified Thickness (inches) min. 15/16 Specified density (pc� min. ADHESION DETERMINATION Diameter of specimen: inches Location: Area of specimen: 0 sq.ft. Recorded force: Ibs. Adhesion (pst� Specified adhesion (psf� min. Notes: Field Representative: Kevin McClure �RVir�n ENGINEERING C�NSULTRNTS FIREPROOFING DATA SHEET Project First Chair Employee Housing Date 8/9/2011 Job Number 10-6522 Reported to Vail Resorts Development Co. Copies to PO Box 959 Avon, CO 81620 Attn: Mr. Kyle Griffith Tube Columns Test number 4 THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION Location: Level 2 Gridline B1/1.8 Location Level 2 Gridline B.1/1.8 � 4 MEASUREMENTS � Thickness #1 117Ch2S AT EACH END OF Thickness #2 inches � 12-INCH LENGTH �, '��. /�� Thickness #3 inches 2 4 2 4 Thickness #4 inches ��`- � �� Thickness #5 inches 3, 3� Thickness #6 inches Thickness #7 inches Thickness #8 inches Test Number: Test Number: Thickness #9 inches 1.� 1 11/16 1.� 1 9/16 Thickness #10 inches 2.� 1 8/16 2.� 1 9/16 Thickness #11 inches 3.� 1 8/16 3.� 1 9/16 Thickness #12 inches 4.) 1 4/16 4.) 1 9/16 Volume of test area: cubic feet Length of test area: inches Width of test area: inches Average thickness: inches DENSITY by Displacement Weight of pan (g) Weight of pan and material (g) Weight of material (grams) 24.3 Average Thickness (inches) 1 8/16 Density (pcf) 22.0 Specified Thickness (inches) min. 14/16 Specified density (pcf) min. 15 ADHESION DETERMINATION Diameter of specimen: 3.25 inches Location: Area of specimen: 0.0576 sq.ft. Recorded force: 20 Ibs. Adhesion (psf) 347 Specified adhesion (psf) min. 200 Notes: Adhesion test perFormed on 8/20/2010. Field Representative: Kevin McClure �RVir�n ENGINEERING C�NSULTRNTS FIREPROOFING DATA SHEET Project First Chair Employee Housing Date 8-12-10 Job Number 10-6522 Reported to Vail Resorts Development Co. Copies to PO Box 959 Avon, CO 81620 Attn: Mr. Kyle Griffith Tube Columns Test number 5 THICKNESS DETERMINATION DENSITY SAMPLE SIZE DETERMINATION Location: Level 2 Gridline E.2/6.0 Location Level 2 Gridline E.2/6.0 � 4 MEASUREMENTS � Thickness #1 117Ch2S AT EACH END OF Thickness #2 inches � 12-INCH LENGTH �, '��. /�� Thickness #3 inches 2 4 2 4 Thickness #4 inches ��`- � �� Thickness #5 inches 3, 3� Thickness #6 inches Thickness #7 inches Thickness #8 inches Test Number: Test Number: Thickness #9 inches 1.) 1 7/16 1.) 1 3/8 Thickness #10 inches 2.) 1 3/8 2.) 1 3/8 Thickness #11 inches 3.) 1 1/4 3.) 1 1/4 Thickness #12 inches 4.) 1 1/4 4.) 1 3/8 Volume of test area: cubic feet Length of test area: inches Width of test area: inches Average thickness: inches DENSITY DETERMINATION Weight of pan (g) Weight of pan and material (g) Weight of material (Ibs) Average Thickness (inches) 1 5/16 Density (pc� Specified Thickness (inches) min. 1 3/16 Specified density (pc� min. ADHESION DETERMINATION Diameter of specimen: inches Location: Area of specimen: 0 sq.ft. Recorded force: Ibs. Adhesion (pst� Specified adhesion (psf� min. Field Representative: Kevin McClure