Loading...
HomeMy WebLinkAboutB11-0137NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES --�. , ,. ��;o�v�� Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0137 Job Address: 1765 ALPINE DR VAIL Location......: A SIDE Parcel No....: 210312307006 OWNER GURY, ELLEN C. 05/24/2011 PO BOX 2576 MALIBU CA 90265 APPLICANT CLIMATE CONTROL CO OF GWS PO BOX 1042 GLENWOOD SPRINGS CO 81602 License: 129-M CONTRACTOR CLIMATE CONTROL CO OF GW� PO BOX 1042 GLENWOOD SPRINGS CO 81602 License: 129-M 05/24/2011 Phone:970-945-2326 05/24/2011 Phone:970-945-2326 Description: REPLACE EXISTING FURNACE WITH ONE LENNOX SLP98UH070V36B FURNACE INCLUDES DUCT ADAPTORS, REPAIR OF RETURN DUCTWORK AS NEEDED, VENTING AND/OR REPLACEMENT OF BROKEN VENTS, DRAIN, NEUTRALIZER, ELECTRICAL TO DISCONNECT ONLY, G4S PIPING, START UP INCLUDING COMBUSTION ANALYSIS AND CLEAN UP. Occupancy: Type Construction: Project #: Applied.....: Issued. . . : Valuation PRJ 11-0179 05/24/2011 05/24/2071 $5,987.00 ,,,,.....,,� ........................,..,................>.......,......,.....,,...,. FEE SUMMARY .....,,.,,...�,.....,.,........».,..,,......,......,........,,>�.....,,.>.,,,...� Building Permit -----------> $125.25 Bldg Plan Check ----------> $81.41 Use Tax Fee-----------------------> $0.00 Electrical Permit ---------> $0.00 Elec Plan Check -----------> $0.00 Restuarant Plan Review--------> Mechanical Permit ------> $120.00 Mech Plan Check ---------> $0.00 $30.00 Additional Fees--------------------> ($206.66) Plumbing Permit --------> $0.00 Plmb Plan Check ---------> $0.00 Recreation Fee--------------------> $0.00 Investigation-----------------------> $0.00 Will Call------------------------------> $5 00 TOTAL PERMIT FEES-------------> $155.00 Payments------------------------------> $155.00 BALANCE DUE-----------------------> $0.00 ,..�....zx...,.�.«..�<..�...�....« .............,,................�...,,......>.�...>.,.......�....<...,.,......�.,,....<.....,...x...�......,...........<,.....,�......>............... DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS F INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:OOAM- • P . 1 �' � . Si nature of Own r or Cont c or Date 1�^, � .-�_i 1 r i�. Name combination permit_012811 .,,.,.,x ..............�..,,..,.,,....,.....,...............,,,,.......�,�,,,...,.,,..,........»,...,.......,..,.,......,.,...,....,.<..>..�.,...........,..,,....,................,. CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11-0137 Owner: GURY, ELLEN C. Address: 1765 ALPINE DR VAIL Location: A SIDE ......................xxx,.,.......,....,,,......,....,,....,...........,,,,.,.,,.....,....>,»..x,x......,..,,.,.............,..,>......,..�.......�....,..,,..,,>.,,�..,........,... combination permit_012811 � # ��l.tT V� T��r ; *.,****�***********************.w************.********************«***********«*********�************,�*****************************«««**********��**** Permit #: 611-0137 Owner: GURY, ELLEN C. REQUIRED INSPECTIONS AND STATUSES Address: 1765 ALPINE DR VAIL Location: A SIDE *****„**************************************«**************************,�****«****�*********.************.*******„******************„*.,***.*****«***..,, Item: 00200 MECH-Rough Item: 00390 MECH-Final combination permit_012811 ***************************************************************************�**************** TOWN OF VAIL, COLORADO Statement *****************+***+***********************+**********�******************�**************** Statement Number: R110000534 Amount: 5125.00 05/24/201111:47 AM Payment Method: Check Init: SAB Notation: 31968-CLIMATE CONTROL ----------------------------------------------------------------------------- Permit No: B11-0137 Type: COMBINATION BLDG PERMIT Parcel No: 2103-123-0700-6 Site Address: 1765 ALPINE DR VAIL Location: A SIDE Total Fees: $155.00 This Payment: $125.00 Total ALL Pmts: $155.00 Balance: $0.00 *****************************************************************************************+** ACCOUNT ITEM LIST: Account Code -------------------- MP 00100003111100 WC 00100003112800 Description ------------------------------ MECHANICAL PERMIT FEES WILL CALL INSPECTION FEE Current Pmts 120.00 5.00 ----------------------------------------------------------------------------- ,. �� ��- � � a� R ��� � � ` �. � �� � : � �� . � � � �g� ����y ('f' l3 �@, ✓ � r b1� �� i i ��€ I �� � .., ����ti Department, of Communi#y Development � 75 South Frontage Roatl , Vail, Colorado 81657 _°�`� T�I�: 9�Q-479-212$ ��£� ' Web w�tw rr;ailgvrr.com � . , Develo�ttien� � �, BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: 1765 Alpine Dr A (Number) (Street) (Suite #) Building/Complex Name: N/A Contractor Information Business Name: Climate Control Company Business Address: 1537 County Rd 130 City Glenwood Springs State: C� Zip: $1601 Contact Name: Gary Kelly Contact Phone: 970-989-5258 or 970-945-2326 Building Permit #: � � �' i�'�l� � I�� I Lot #: Block # Subdivision: '' Work Class: New ( ) Addition ( ) Alteration ( �/ ) Type of Building: : Single-Family ( ) Duplex ( ) Multi-Family ( ) Commercial ( ) Other ( ) " Work Type: Interior (✓ ) Exterior ( ) Both ( ) Contact E-Mail: 9kelly@cccgws.com or ecraig@cccgws.com 129-M Work Included Contractor Registration Number: ' Electrical ( )Yes ( )No ( X ' Mechanical ( �/ )Yes ( )No ( Owner/Owner's Representative Signature (Required) Plumbing ( )Yes ( )No ( Project Information Building ( )Yes ( )No ( Valuation of Plans Inciuded Work )Yes ( )No )Yes ( )No � I ��. / )Yes ( )No )Yes ( )No Owner Name: Vury, tllen 2103-123-07-006 Value of all work being performed: $� ( Y�� �� PaYCeI #: �value based on IBC Section 109.3 & IRC Section 108.3� (For Parcel #, contact Eagle County Assessors Office at (970328-8640 or visit N/A www.ea9iecour,ty.�sipatie� Electrical Square Footage Detailed Scope and Location of Work: Replace existing furnace with (1) Lennox SLP98UH070V36B furnace includes duct adaptors, repair of return ductwork as needed, venting and/or replacement of broken vents, drain, neutralizer, electrical to disconnect only, gas piping, start up including combustion analysis & clean up. Equipment specs are attached. (use additional sheet if necessary) For Office Use Only: Fee Paid: Received From: Cash Check # _ CC: Visa / MC Last 4 CC # Auth # exp date: Date Received: �C�C��(�[1MC D MAY 0 6 2[J11 T�Wt'�l OF 1/AIL O1-Jan-11 Recreation Fees Per Sq. Ft Tvpe HR (Hillside Residential) ABD (Arterial Business District) 56/RD (Ski Base/Rec District) PD (Parking District) PUC (Public Use District) SFR (Single Family Residential) R (Two Family Residential) RC (Residential Cluster) R P/S (Primary/Secondary Residential) LDMF (Low Density Multi-family) MDMF (Medium Density Multi-family) Exam�le: Building Permit One-Family Addition $100,000.00 Valuation 1000 sq ft added OTHER Building Permit Fees: Fee $0.15 $1.00 $0.70 $0.10 $0.10 $0.10 HDMF (High Density Multi-family) LMU1 (Lionshead Mixed Use 1) LMU2 (Lionshead Mixed Use 2) PA (Public Accommodation) CCl (Commercial Core 1) CC2 (Commercial Core 2) $0.15 CC3 (Commercial Core 3) $0.30 CSC (Commercial Service Center) $0.15 HS (Heavy Service) $0.35 A (Agricultural & Open Space) $0.70 SDD (Special Development District) Permit Fee $993.75 Plan Review Fee $645.94 Construction Use Tax $1,800.00 Recreation Fees $100.00 Will Call Inspection $5.00 TOTAL $3,544.69 $1.00 $1.00 $1.00 $1.00 $1.00 $1.00 $1.00 $1.00 $1.00 $0.10 Rate zone district ap- plicable to density projected �! Revisions: $55.00/hour, minimum 2 hours. �! Inspections outside normal business hours, re-inspections and other inspections: $47.00/hour rr! (For Design Review Board, Planning & Environmental Commission and other land use applications, see the application for the applicable fees. Instructions for calculating MECHANICAL or PLUMBING PERMIT FEES (see applicable section below): 1. Determine the valuation (labor & materials) Z. Using the valuation, calculate the base Permit Fee 3. Calculate the Plan Review Fee (multiply the Plumbing or Mechanical Permit Fee by 25% to determine the fee) 4. Calculate the Construction Use tax (see formula listed in Building Permit section on page 1. Only for permits OVER $10,000 where there is NO associated building permit) �-------- - 5. Add $5.00 for Will Call**Inspection � � � � �% � D Plumbinq: Permit Fee: $15.00 per $1,000 valuation (valuation: $500 per trap opening) MAY 0 6 20ii Plan Review Fee: 25% of Permit Fee � � Mechanical: `�qg7' _ � l> �D` - l � ` � �W� 0� �%AI�. Permit Fee: $20.00 per $1,000 valuation (valuatio�. $500 per trap opening) 52.. Plan Review Fee: 25% of Permit Fee -- �a�•= X o2J'r ��O �. c,.��• �_ OTHER Mechanical & Plumbing Permit Fees: w ��� C9,11 ���� - �► rr! Revisions: $55.00/hour, minimum 2 hours. �`� �' �! Inspections outside normal business hours, re-inspections and other inspections: $47.00/hour 3! 1 r� � -� wrightsoft� Load Short Form Entire House Climate Control Company Job: N/A Date: Mar 28, 2011 By: TLM 1537 CR 130, Glenwood Springs, CO 81601 Phone: 970-945-2326 Fax: 970-945-8128 Email: tmadara@cccgws.com Web: www.climatecontrolcompany.com ' # • • For: Don Gury 1765A Alpine Drive, Vail, CO �- • s • Htg Clg Infiltration Outside db (°F) -19 85 Method Simplified Inside db (°F) 70 70 Construction quality Semi-tight Design TD (°F) 89 15 Fireplaces 0 Daily range - H Inside humidity (%) 50 50 Moisture difference (gr/Ib) 68 -27 HEATING EQUIPMENT Make Trade Model GAMA ID Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat ROOM NAME Room1 80 AFUE 0 Btuh 0 Btuh 0 °F 775 cfm 0.029 cfm/Btuh 0 in H20 Area Htg load (ft2) (Btuh) ..� Entire House d 660 Other equip loads Equip. @ 0.90 RSM Latent cooling TOTALS ..� COOLING EQUIPMENT Make Trade Cond Coil ARI ref no. Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 27021 27021 0 27021 Clg load (Btuh) 10898 10898 � 0 9841 0 9841 IU 0 SEER 0 Btuh 0 Btuh 0 Btuh 775 cfm 0.071 cfm/Btuh 0 in H20 1.00 Htg AVF Clg AVF (cfm) (cfm) 775 775 775 775 775 ' 775 ,.A...,..,.,�,.�,aa..�._,.,,.w:.-.�._� . ��L�U� � MAY 0 � 2011 Bold/italic values have been manua/ty oveiridden �� ���� ���� ��, y Printout certified by ACCA to meet all requirements of ManuaT�"S�i'i"Fd:""""�""".���"'"� _ �, -�1- wrightsofY" Right-SuiteQ�l Universal 8.0.02 RSU13372 2011-Apr-20 15:43:30 p�� ... Design Info\Heat Load calculations�2011\Gury 1765A 032811.rup Calc = MJ8 Front Door faces: Page 1 DIMENS106VS - INCt-3E5 CMM) - HOi21ZOMTAL i'OSITION LEFT-HAND AIR DISCNARGE r � CONDENSATE TRAP CONNECTION 12-5/8 (321) (Bottom) Bottom � AIR 6-9/16 (167) Top FLOW ELECTRICAL INLET 9 (229) Bottom (Top or Bottom) � 6-1/2 (165) � , Bottom + � o � �-2 (51) Top or Bottom �27-3/4� COMBUSTION (705) g��g AIR INTAKE �(14) / 9/16 19-7(16 / I (14) (494) �}-) SUPPLY B v A AIR D OPENING + EXHAUST AIR / � 1-7l8 (48) OUTLET 3-1/4 (83) END VIEW TOP VIEW �GAS PIPING INLET (Top or Bottom) _ 33 � 1-1/2 (38)� �27-3/4 J (838) Front Panel 3�q (705)-'1 �19) � 3-1/4 23-1/2 AIR �95� (591) FLOW A C RETURN � AIR OPENING FRONT VIEW R1GHT-HAND AIR DISCNARGE END VIEW r CONDENSATE � � � L' �J � TRAP CONNECTION D (Bottom) p�R 12-5/8 (321) � p� � � ���� FLOW �' Bottom �� 6-1/2 (165) Bottom 9 (229) Top U 6-9/16 (167) Bo �� +�� � t� � l � � �.,J P�C Y.o �� 2 (51) � Top or Bottom ELECTRICAL INLET GAS PIPING INLET (Top or Bottom) TOP VIEW (Top or Bottom) EXHAUST AIR 27-3l4 1-1/2 38 33 OUTLET 27-3/4 � (705)� � Front Panel �(838)� 1-7/8 (834 (705)� (48) \ 23-1/2 3-1/4 + 19-7/16 (591) (95) D (494) I ''�1 9/16 RETURN C A FLOW �� A + SUPPLY B (14) AIR AIR OPENING OPENING END VIEW (19) FRONT VIEW COMBUSTION END VIEW (14) AI R I NTAKE Model No. in. /�� SLP98UH070V36B 17-1/2 1 SLP98UH090V36C SLP98UH090V48C 2� SLP98UH090V60C SLP98UH11aV60C SLP98UH135V60D 24-1/2 SLP98UHV / Page 14 A B C D mm in. mm in. mm in. mm 446 16-3/8 416 16 406 7-5/8 194 533 19-7/8 505 19-1/2 495 9-3/8 238 622 I 23-3/8 I 594 I 23 I 584 � 11-1/8 I 283 SPECIFICATIONS Gas Model No. Heating ' AFUE Performance Maximum Input- Btuh Connections in. Indoor Blower Electrical Data Output- Btuh Temperature rise range - °F Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane Minimum Input- Btuh Output - Btuh Temperature rise range - °F Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane High static- in. w.g. Intake / Exhaust Pipe (PVC) Gas pipe size IPS Condensate Drain Trap (PVC pipe) - i.d. with furnished 90° street eibow with field supplied (PVC coupling) - o.d. Wheel nominal diameter x width - in. Motor output - hp Tons of add-on cooling Air Volume Range - cfm Voltage (Maximum Amps) Blower motor full load amps Maximum overcurrent protection Shipping Data NOTE - Filters and provisions ' Annual Fuel Utilization EfficiE fumaces. SPECI FICAYION Gas Heating Periormance .._�:_... on DOE test procedures and S��l�t �) � %�3� � Mode! SLP98U 070V366 97.0% 66, 000 64, 000 50-80 3.5 / 10.0 SLP98UHd90V36C 98.0%0 88,000 85, 000 60 - 90 3.5 / 10.0 23, 000 31, 000 22, 500 30, 500 35 - 65 35 - 65 0.5 / 1.5 0.5 / 1.5 0.8 2/2 1/2 1/2 1/2 slip x 1/2 Mipt 1/2 siip x 1/2 NPT 10x9 1/2 2-3 339 - 1365 7.7 15 138 0.8 2/2 1/2 1 /2 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 NPT 10x9 1/2 2-3.5 520 - 136Q 120 volts - 60 hertz - 1� 7.7 15 155 SLP98UH090V48C 97.5% 88,000 85,000 50 - 80 3.5 / 10.0 31,000 30,500 35 - 65 0.5/1.5 0.8 2/2 1!2 1/2 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 NPT 11 x 11 3!4 2.5-4 528 - 1770 10.1 15 165 FTC labeling regulations. Isolated combustion system rating for non-weatherized 98UH090V60C SLP98UH110V60C 98.2% 97.5% 88 000 1 SLP98UH135V60D 97.5% �.�a,.����,.��� ���N��- ����� 1 0,000 ���,vvv Output- Btuh 85,000 106,000 128,000 Temperature ris2 range -°F 50 - 80 50 - 80 55 - 85 Gas Manifold Pressure (in. w.g.) 3.5 / 10.0 3.5 / 10.0 3.5 / 10.0 Nat. Gas ! LPG/Propane Minimum Input- Btuh 31,000 39;000 46,000 Output- Btuh 30,500 38;500 45,000 Temperature rise range -°F 35 - 65 35 - 65 35 - 65 Gas Manifold Pressure (in. w.g.) 0.5 / 1.5 0.5 / 1.5 0.5 / 1.5 Nat. Gas / LPG/Propane High static - in. w.g. 0.8 Q.8 0.8 Connections Intake / Exhaust Pipe (PVC) 2/ 2 2/ 2 2/ 2 �n• Gas pipe size IPS 1/2 1/2 1/2 Condensate Drain Trap (PVC pipe) - i.d. 1/2 1/2 1/2 with furnished 90° street elbow 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt 1/2 slip x 1/2 Mipt with field supplied (PVC coupling) - o.d. 1/2 slip x 1/2 NPT 1/2 slip x 1/2 NPT 1/2 slip x 1/2 NPT Indoor Wheel nominal diameter x width - in. 11 x 11 11 x 11 11 x 11 Blower Motor output- hp 1 1 1 Tons of add-on cooling 3- 5 3- 5 3.5 - 5 Air Volume Range - cfm 375 - 2195 554 - 2125 634 - 2190 Electrical Data Voltage (Maximum Amps) 120 volts - 60 hertz - 1 phase Blower motor full load amps 12.8 12,8 12.8 Maximum overcurrent protection 20 20 20 Shipping Data Ibs. - 1 package 165 175 190 NOTE - Filters and provisions for mounting are not fumished and must be field provided. ' Annual Fuel Utilization Effciency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system reting for non-weatherized fumaces. SLP98UHV / Page 9 � - 06-20-2011 Inspection Request Reporting Page 17 4'37 pm V�I, CO - Citv Of Requested Inspect Date: Tuesday, June 21, 2011 Site Address: 1765 ALPINE DR VAIL A SIDE A/P/D Information Activity: B11-0137 Type: COMBO Sub Type: ADUP Status: ISSUED Const Type: Occupancy: Use: Insp Area: Owner: GURY, ELLEN C. Contractor: CLIMATE CONTROL CO OF GWS Phone: 970-945-2326 Description: REPLACE EXISTING FURNACE WITH ONE LENNOX SLP98UH070V366 FURNACE INCLUDES DUCT ADAPTORS REPAIR OF RETURN DUCTWORK AS NEEDED, VENTING AND/OR REPLACEMENT OF UP INCLU �NT AIN TION ANALYSR� AND CLEANLUP DISCONNECT ONLY, GAS PIPING, START Ite . 390 MECH-Final Request : Comment : 989-0322 Assianed T � *"*""*"'"*" i � �v `V � �> �, - � � � / Requested Time: 08:30 AM Phone: Entered By: MHAEBERLE K � Inspection History ' Item: 200 MECH-Rough "` Approved `* 06/10/11 Insp ector: JRM Action: AP APPROVED Comment: INSULATE DUCTS TERMINATION OF VENTS MUST MEET LOCAL CODE AMENDMENT Item: 390 MECH-Final REPT131 Run Id: 13214