Loading...
HomeMy WebLinkAboutB11-0141NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES M OF R Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11 -0141 Project #: PRA 1 -0231 Job Address: 174 E GORE CREEK DR VAIL Applied.....: 05/25/2011 Location......: LODGE AT VAIL BALLROOM CLOSET Issued...: 06/03/2011 Parcel No....: 210108221001 OWNER LODGE PROPERTIES INC 05/25/2011 C/O THE LODGE AT VAIL 174 E GORE CREEK DR VAIL CO 81657 APPLICANT BLU SKY RESTORATION CONTRACT 05/25/2011 Phone: (303) 789 -4258 3040 S. TEJON STREET ENGLEWOOD COLORADO 80110 License: 910 -B CONTRACTOR BLU SKY RESTORATION CONTRACT 05/25/2011 Phone: (303) 789 -4258 3040 S. TEJON STREET ENGLEWOOD COLORADO 80110 License: 910 -B Description: WATER AND MOLD MITIGATION SERVICES PERFORMED IN CLOSET OF BALLROOM. Occupancy: Type Construction: Valuation: $5,286.00 *#**#*####****************************#**##*###### # # # # # # * * * # * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY **********#************ R***** k***#****#*#**##### # # # * # # # # # # # # # # * # # # # # # # * # * * # * # ## Building Permit ------ - - - - -> $125.25 Bldg Plan Check ----- - - - - -> $81.41 Use Tax Fee------------------ - - - - -> $0.00 Electrical Permit ---- - - - - -> $0.00 Elec Plan Check ------ - - - - -> $0.00 Restuarant Plan Review--- - - - - -> $0.00 Mechanical Permit - - - - - -> $0.00 Mech Plan Check ---- - - - - -> $0.00 Additional Fees--------------- - - - - -> $0.00 Plumbing Permit --- - - - - -> $0.00 Plmb Plan Check ---- - - - - -> $0.00 Recreation Fee--------------- - - - - -> $0.00 Investigation------------------ - - - - -> $125.25 Will Call ------------------------------ > $5.00 TOTAL PERMIT FEES --- ---------- > $336.91 Payments -- ---------------------------- > $336.91 BALANCE DUE------------------ - - - - -> $0.00 DECLARATIONS I hereby acknowledge that ave read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I ag ee to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zo ing and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicableVhereto. I REQUEST FOR P I N SHALL BE E TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4. 0 ig atM of Qv& er or Contractor i5ate nt Name combination permit_012811 CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11 -0141 Owner: LODGE PROPERTIES INC LODGE AT VAIL BALLROOM CLOSET Address: 174 E GORE CREEK DR VAIL Location: combination permit_012811 7"oWN OF VAIL .... " REQUIRED INSPECTIONS AND STATUSES Permit #: B11 -0141 Owner: LODGE PROPERTIES INC LODGE AT VAIL BALLROOM CLOSET Address: 174 E GORE CREEK DR VAIL Location: Item: 00060 BLDG - Sheetrock Nail Item: 00050 BLDG - Insulation Item: 00030 BLDG - Framing Item: 00090 BLDG -Final combination permit_012811 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** TOWN OF VAIL, COLORADO Statement Statement Number: R110000591 Amount: $262.91 06/03/201112:28 PM Payment Method:Credit Crd Init: LC Notation: credit card from Joshua Grange Blusky restoration ----------------------------------------------------------------------------- Permit No: Bll -0141 Type: COMBINATION BLDG PERMIT Parcel No: 2101- 082 - 2100 -1 Site Address: 174 E GORE CREEK DR VAIL Location: LODGE AT VAIL BALLROOM CLOSET Total Fees: $336.91 This Payment: $262.91 Total ALL Pmts: $336.91 Balance: $0.00 ************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** ACCOUNT ITEM LIST: Account Code -------------- Description Current Pmts BP - - - - -- 00100003111100 --------- --------------- - - - - -- BUILDING PERMIT FEES ------ - - - - -- 125.25 PF 00100003112300 PLAN CHECK FEES 7.41 PN 00100003153000 INVESTIGATION FEE (BLDG) 125.25 WC 00100003112800 WILL CALL INSPECTION FEE 5.00 Lod 9 � ak vo r c ::) 1 �uu D Z t� iii - 1i1 N 99� 1 Remove 4 - klace We+ 518` Sl ft4fft c M. t2-! 1 C /'O's e�— a 0 N M 1! out zck 0 ' to hn ReJOlm a sh er�roc, and R -3O iASJ1O*OA a > O O n 3 EL= Q � z � I -/ �Dy 0 o O M —. . z M C? N O N 5- i8-2o11 ReMode aa.Ya Repla GJef Sl8 u shy °mac Cn� R- !c f3gt¢ i 75 South Frontage Vail, Coloraq *. 970 r Devlo erevle BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) 4 , 'c Project Street Address: LURooM Project #: /7Y 4C-asl- (mare Cfeat< A / - AlR (Number) (Street) - I ( DRB #: Suite #) Building /Complex Name: Lx�Q A, /— ycU ! / Building Permit #: �1 Q f `T " � ti/AlL vit.t,R�6 L045f a�4f P M � C011<40S '� Lot #ABC-Block #_ S C Subdivision : i t . , F! Lt tJGI 1 Contractor Information Business Name: No S{�/ �eS t•CJt�� jG� Business Address: 770 Lin A ber'9A Dr 0 5 City 6yr�csV✓ State: G Zip: / Eg 31 Contact Name: f ? at C GJ s (� Contact Phone: 7 70 — 2-0 t ^ I Y3 F Contact E -Mail: jM Ct /cu Co. Contractor Registration Number: X Owner /Owner's Representative Signature (Required) Project Information t *J Owner Name: U ot / R Parcel #: 2 to i o 8 221 oo I (For Parcel #, contact Eagle County Assessors Office at (970 -328 -8640 or visit www.eaglecounty.us/patie) Work Class: New ( ) Addition ( ) Alteration (04t) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family ( ) Commercial K Other( ) Work Type: Interior >C Exterior( ) Both( (use additional sheet if necessary) For Office Use Only: Fee Paid: $ 1-a x Received From: (` !61 fy\A.LC u 1"r Cash Check # CC: Visa / MC Last 4 CC # 3ay & exp date: Auth # QaySSa A%ARe- ►�v4LcutY Date Received: D MAY 2 4 7011 TOWN OF VAIL t1I0[mcall - el Valuation of Work Included Plans Included Work Electrical ( )Yes 1><)No ( )Yes ( )No Mechanical ( )Yes X)No ( )Yes ( )No Plumbing ( )Yes K)No ( )Yes ( )No Building ( )OYes ( )No ( ,<Yes ( )No J Value of all work being performed: $ s - (value based on IBC Section 109.3 & IRC Section 108.3) Electrical Square Footage (use additional sheet if necessary) For Office Use Only: Fee Paid: $ 1-a x Received From: (` !61 fy\A.LC u 1"r Cash Check # CC: Visa / MC Last 4 CC # 3ay & exp date: Auth # QaySSa A%ARe- ►�v4LcutY Date Received: D MAY 2 4 7011 TOWN OF VAIL t1I0[mcall - el 1)?01d Detailed Scope and Location of Work: LJOf DP/cr��n e� 1,1 eIoLSe (use additional sheet if necessary) For Office Use Only: Fee Paid: $ 1-a x Received From: (` !61 fy\A.LC u 1"r Cash Check # CC: Visa / MC Last 4 CC # 3ay & exp date: Auth # QaySSa A%ARe- ►�v4LcutY Date Received: D MAY 2 4 7011 TOWN OF VAIL t1I0[mcall L-, 1 i c- B1uSKY Restoration Contractors BIuSKY Restoration Contractors Western Slope Division PO Box 1380 Gypsum, CO 81637 P- 970- 328 -2223 F- 970- 328 -2333 Client: Lodge at Vail - Ballroom Property: 174 East Gore Creek Vail, CO 81658 Operator Info: Operator: DPLAIN Estimator: Plain, David M. Business: PO Boa 1380 Gypsum, CO 81637 Type of Estimate: Water Damage Date Entered: 4/25/2011 Date Assigned: 4/21 /2011 Date Est. Completed: 5/13/2011 Date Job Completed: Price List: CORE7X_APRl l Restoration/Service/Remodel Estimate: 2011 -04-25 -0734 Business: (970) 754 -7896 Cellular: (970) 331 -4844 Blu SKY Restoration Contractors, Inc. is a specialty general contractor specializing in assisting the owners and insurers of residential, commercial, industrial, medical, public and multi- family buildings in recovery following fire, water and most possible types of emergency losses. Blu SKY also provides Capital Improvement services and Construction Defect consulting and reconstruction. We have more than 100 combined years of experience at our project management level alone. Our services include; general contracting, technical recovery solutions, drying, mold remediation, consulting, engineering, and architectural services. We are licensed in every major municipality and county in Colorado and carry General Liability, Auto, Workers Compensation and Pollution/Mold insurance policies. Blu SKY cares about our cutomers and formed our business with the sole purpose of becoming the best company in our industry. We established our founding principles and Cloud 9 Commitments to lead us through your project. We have a complete list of references and customer testimonials that will agree! While Blu SKY maintains an excellent staff of consturction professionals, we may need to subcontract all or some of the work. Blu SKY reserves the right to take any and all applicable trade discounts and substitute suppliers and vendors at our discretion, independent of estimates provided. Any supplier or vendor bids provided are for reference purposes only and that vendor may or may not be ultimitely used for the project. We have an excellent array of committed suppliers and vendors and will select the best team of individuals for your project. You can be guaranteed that we will treat you with honesty and integrity with a personal dedication to your project. It is our goal to make your recovery time and headaches very minimal. Our expertise is second to none in our industry and will become evident once our processes are implemented. If I can answer any questions or begin the scheduling phase of your project, please contact me at the embers listed below. Thank you for the opportunity to submit our proposal to you for review. Sincerely, David Plain, Estimator I�1 MAY 2 4 211 TOWN of v�� � J BluSKY Restoration Contractors B1uSKY Restoration Contractors Western Slope Division PO Box 1380 Gypsum, CO 81637 P- 970 - 328 -2223 F- 970 -328 -2333 2011 -04 -25 -0734 Main Level Main Level DESCRIPTION QNTY Taxes, insurance, permits & fees (Bid item) TOV Permit fee Ballroom Closet DESCRIPTION 1.00 EA Height: 10' QNTY R &R Blown -in insulation - 8" depth - R19 320.00 SF Peel & seal zipper 1.00 EA Water extraction from floor - Heavy 63.00 SF Tear out trim/base 32.00 LF Tear out wet drywall, cleanup, bag for disposal 383.00 SF Equipment setup, take down, and monitoring (hourly charge) 2.00 HR Ducting - lay -flat 20.00 LF Used to create negative air. Run to exterior door Apply anti - microbial agent 383.00 SF Negative air fan/Air scrubber (24 hr period) - No monit. 3.00 DA Add for personal protective equipment (hazardous cleanup) 2.00 EA Hazardous Waste/Mold Cleaning Technician - per hour 5.00 HR Tear out wet carpet pad and bag for disposal 63.00 SF Tear out wet non - salvageable carpet, cut & bag for disp. 63.00 SF Plumber - per hour 5.50 HR Labor and materials to make repairs to drains and 3 leaks 5/8" drywall - hung, taped, floated, ready for paint 383.00 SF Paint the walls and ceiling - two coats 383.00 SF Carpet Installer - per hour 4.00 HR Labor to install customer supplied carpet Carpet pad 63.00 SF Plain, David M. MAY 2 4 2011 TOWN OF VAIL 2011 -04 -25 -0734 5/13/2011 Page:2 sk B1uSKY Restoration Contractors BluSKY Restoration Contractors Western Slope Division PO Box 1380 Gypsum, CO 81637 P- 970 -328 -2223 F- 970 -328 -2333 Grand Total Areas: 320.00 SF Walls 63.00 SF Floor 0.00 SF Long Wall 63.00 Floor Area 381.33 Exterior Wall Area 0.00 Surface Area 0.00 Total Ridge Length 63.00 SF Ceiling 7.00 SY Flooring 0.00 SF Short Wall 74.11 Total Area 34.67 Exterior Perimeter of Walls 0.00 Number of Squares 0.00 Total Hip Length 383.00 SF Walls and Ceiling 32.00 LF Floor Perimeter 32.00 LF Ceil. Perimeter 320.00 Interior Wall Area 0.00 Total Perimeter Length p ��'� Lc:;uuU= MAY 24 2011 TOWN OF MA 2011 -04 -25 -0734 5/13/2011 Page:3 1, . u c by a 0 N M V'1 we-move �- k(ace 4)e+ `S/g u ►� ce�bc. � �i t2-11 baf-f- pmoa P4 reola.Le- CX4 R -30 iAsula¢iom N .a C �emo�e �d r2e�(a c.e C.�--+ Sls" 6heWoc4 a"j R- !t 3 -+ R ernouls- 41 4.0-r Base Sf 0: 4e- � to A,'t'a, P-kt �hn' MAY 2 4 2011 TOWN OF VAIL M 0 N O O N Fa i I �! 1 T 1 f %i a i I I pmoa P4 reola.Le- CX4 R -30 iAsula¢iom N .a C �emo�e �d r2e�(a c.e C.�--+ Sls" 6heWoc4 a"j R- !t 3 -+ R ernouls- 41 4.0-r Base Sf 0: 4e- � to A,'t'a, P-kt �hn' MAY 2 4 2011 TOWN OF VAIL M 0 N O O N Fa Consulting Asbestos Inspection and Sampling Report The Lodge at Vail - Ballroom A Storage Closet 174 E Gore Creek Dr, Vail, Colorado 81657 Presented To: Mr. Mark Malcuit BluSKY Restoration Contractors 770 Lindbergh Dr, #507 Gypsum, CO 81637 Performed & Prepared By: Mr. Steve Shurtliff DS Consulting, Inc. PO Box 6864 Avon, CO 81620 (303) 378 -1544 Project Details: Project Number: 4123 Conducted: May 20, 2011 EXECUTIVE SUMMARY On May 20, 2011, Mr. Steve Shurtliff with DS Consulting, Inc. (DSC) performed a limited asbestos inspection and performed asbestos bulk- sampling within the storage closet of Ballroom A of the Lodge at Vail located at 174 E Gore Creek Dr, Vail, Colorado, in order to identify potentially hazardous friable and non - friable asbestos - containing materials (ACM) within a portion of the above - referenced area. The Colorado Department of Public Health and Environment's (CDPHE) Regulation 8, Part B defines an asbestos - containing material (ACM) as a material containing more than 1% asbestos. Mr. Shurtliff collected a total of three (3) asbestos bulk - samples from the following locations within the building: Drywall Wall Texture - 3 Locations • Ballroom A - Storage Closet Wall All three (3) bulk - samples were analyzed by a National Voluntary Laboratory Accreditation Program (NVLAP) accredited lab in Denver, Colorado. All three (3) bulk - samples reported as none - detect for asbestos - (see Appendix B for laboratory report). E n MAY 2 4 �Q11 0j PROJECT OVERVIEW I. Introduction A limited asbestos inspection and bulk - sampling for ACM was conducted within the storage closet of Ballroom A of the Lodge at Vail located at 174 E Gore Creek Dr, Vail, Colorado, by Mr. Shurtliff on May 20, 2011 at the request of Mr. Mark Malcuit with B1uSKY Restoration Contractors. Mr. Shurtliff is a Colorado State Certified Building Inspector; having EPA Accreditation #15413 (see Appendix A for certificate). The purpose of the inspection was to identify, sample and assess potentially hazardous friable and non - friable ACM within the closet. II. Structural Design The structure is a multi -level hotel. III. Sampling and Analytical Procedures The inspection, assessment and sampling were conducted by an EPA and AHERA accredited Building Inspector qualified by experience, education and training in the recognition of potential ACM and approved bulk - sampling techniques. The asbestos bulk - sampling was conducted on suspect ACM with a limited number of bulk - samples being collected within the building. The inspection, assessment and sampling were performed in accordance with Environmental Protection Agency / AHERA recommended procedures. These procedures call for the visual inspection of the area of concern and the collection and analysis of representative bulk - samples of suspect material. Some minor destructive sampling was conducted. Walls, columns and perimeter pipe chases were not broken into in order to locate and quantify suspect ACM. It should be noted that additional ACM might be located in these and other inaccessible areas. Random bulk - samples, representative of the suspect asbestos - containing building materials (ACBM) of each homogeneous area (HA), were collected according to the guidelines published as Environmental Protection Agency (EPA) Final Rule: Title II of the Toxic Substances Control Act (TSCA), 15 USC, Sections 2641 through 2654 and in compliance with 40 CFR, Part 763. Representative sampling is based on the following criteria: 1. The distribution of the suspect material throughout the HA. 2. The suspect material's physical characteristics and application. 3. Random sampling patterns determined for each HA. Suspect materials sampled and analyzed should be considered to be representative of materials in each HA if they exhibit similar physical characteristics and the application of the sampled material can be correlated to the application of un- sampled material. Bulk - samples collected were analyzed utilizing the EPA's Method for the Determination of Asbestos in Bulk Building Materials (EPA 600/R/116, July, 1993) and the McCrone Research Institute's The Asbestos Particle Atlas as methods references. Analysis of the bulk - samples was performed on the "date reported," as listed in the bull R , FE D C MAY 2 4 2011 3 TOWN OF VAIL IV. Notes on Report Format Suspect materials alike in appearance and application were sampled as HAs. Suspect materials were divided into three classifications: 1. Surfacing Material: sprayed or troweled onto structural building member. 2. Thermal System Insulation (TSI): any type of pipe, boiler, tank, or duct insulation. 3. Miscellaneous Material: other suspect materials, floor tile, sheet vinyl /linoleum, ceiling tiles, insulation, and finishing materials. Condition assessments were performed by the accredited inspector at the time of inspection. Condition assessments are listed in the following section. Ratings of "good," "damaged," and "significantly damaged" are meant to indicate the overall condition of the material. A material in "good" condition has no visible damage or deterioration, or showing only very limited damage or deterioration. A material in "damaged" condition has the following characteristics: The surface is crumbling, blistered, water - stained, gouged, marred or otherwise abraded over less than one - tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. A material in "significantly damaged" condition has one or more of the following characteristics: • The surface is crumbling or blistered over at least one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). • One -tenth (one - quarter, if localized) of the material is hanging from the surface, deteriorated, or showing adhesive failure. • Water stains, gouges, or mars are over at least one -tenth of the surface if the damage is evenly distributed (one - quarter if the damage is localized). Accumulation of powder, dust or debris similar in appearance to the suspect material on surfaces beneath the material can be used as confirmatory evidence. Response- action recommendations for asbestos - containing HAs are listed in the section VII. Recommendations may be for more than one HA, if materials are alike. Recommendations are either "general" or "immediate." An immediate recommendation indicates the presence of asbestos greater than 1% within the bulk - sample, or a bulk - sample in the same HA, and should be addressed accordingly. A general recommendation indicates asbestos does not exist greater than 1% within the bulk - sample, or all bulk - samples in the same HA, and no further abatement activities are required for removal of the material. Any sample reporting a "TRACE" amount of asbestos must be considered to be positive for asbestos greater than 1% unless it is analyzed by the point -count method to be less than 1 %. V. Inspector Comments No asbestos - containing material was identified during the bulk - sampling conducted within the storage closet of Ballroom A of the Lodge at Vail located at 174 E Gore Creek Dr, Vail, Colorado. A total of three (3) bulk - samples of drywall wall texture were collected from the storage closet. All three (3) bulk - samples reported as none - detect for asbestos. 4 MAY 2 4 2011 TOWN OF VAIL VI. Homogeneous Area Descriptions The following section contains sampled HA descriptions and sample locations. Percent - asbestos content for each sample indicated can vary depending on sample locations, homogeneity of the materials, and type of application. ND= None - detect. *The quantities of materials listed in this report are general approximations used specifically to determine the number of bulk - samples of each material to be collected. These quantities should not be used for any other purpose. On -site verification of the exact quantity of material is required for bidding purposes. Homogeneous Area #01 Sample #: DW1 -1 Homogeneous Area #01 Sample #: DW1 -2 Sample Description: Drywall Wall Texture Sample Description: Drywall Sample Location: Ballroom A - Storage Closet Wall Sample Location: Ballroom A - Storage Closet Wall Material Classification: Surfacing Material Material Classification: Surfacing Material Material Quantity: <1,000ft Material Quantity: <1,000ft Material Condition: Significantly Damaged Material Condition: Significantly Damaged Layers - Asbestos Content: White joint compound - ND White tape - ND Tan /white drywall - ND White compound w multicolored paint - ND Layers -Asbestos Content: White joint compound - ND White tape - ND White compound w /tan paint - ND Tan white drywall - ND Recommendations: GENERAL - See Section VII Recommendations: GENERAL - See Section VII Hom oge n eo us Sample #: DW1 -3 Sample Description: Drywall Sample Location: Ballroom A - Storage Closet Wall Material Classification: Surfacing Material Material Quantity: <1,000ft Material Condition: Significantly Damaged Layers - Asbestos Content: White tape - ND White compound w /tan paint - ND White joint compound - ND Recommendations: GENERAL - See Section VII VII. Recommendations D IEc�IFadE D MAY 2 4 2011 I. TOWN OF VAIL GENERAL: The laboratory results of the potential ACM sampled within the storage closet of Ballroom A of the Lodge at Vail located at 174 E Gore Creek Dr, Vail, Colorado, indicate the bulk - samples of drywall wall texture reported as none - detect for asbestos. No professional abatement activities are recommended to remove the above - referenced material. F1 DISCLAIMER AND LIMITATIONS DSC performed the activities included in this report in a manner consistent with the level of care and expertise exercised by members of the environmental consulting profession. DSC performed all activities in accordance with all applicable federal, state, and local regulations, generally accepted standards and professional practice. No warranty is either expressed or implied. DSC assumes no responsibility or liability for error in public information utilized, statements from sources other than DSC, or developments resulting from situations outside the scope of this project. This report and the details provided within outline the inspection activities on the date(s) indicated, the limited number of bulk - samples collected, and the laboratory results of those bulk- samples. The laboratory results contained in this report apply specifically to the materials in which bulk - samples were collected. The results do not include or apply to any other materials within the structure that were not sampled but may contain asbestos. Additional inspection and bulk - sampling activities would be required to determine if any other materials contain asbestos. The information contained in this report is intended as supplementary material and is NOT to be used as the scope of work for abatement activities. DSC can provide a full scope of work for abatement upon request. The results of any surfacing material indicated in this report also include any associated overspray with that material, e.g., under carpet, above suspended ceilings, etc. D IEGFE 0M19 D MAY 2 4 2011 f i TOWN OF VAiL rol APPENDIX A - INSPECTOR CERTIFICATION This certifies that Steve Shurtliff Certification No: IS413 4 ltas met the requirements of '25- 7 -507. C.R.S. and Air Quality Control Commission Regulation No. 3, Part B. and is. hereby certified by the state of Colorado in the lollowing discipline: Building Inspector* Issued: G!12f2010 Expires on: 611212011 f = + 7xi.. •- Yr*+finre i..aNJ eair+oirh Wrpuaansior� a! � rwrrrrr t ».anawpr.a +rw aau.rrf caaras _' .n'�rwnattmfAr diurpllne�peel,(rd nhurc. APPENDIX B - LABORATORY REPORT E E MAY 2 4 2011 7 TOWN OF VAIL r - STATE OF COLORADO ASBESTOS CERTIFICATIO'ti Colorado Department of Public Health �+ and Environment Air Pollution, Conical Division N This certifies that Steve Shurtliff Certification No: IS413 4 ltas met the requirements of '25- 7 -507. C.R.S. and Air Quality Control Commission Regulation No. 3, Part B. and is. hereby certified by the state of Colorado in the lollowing discipline: Building Inspector* Issued: G!12f2010 Expires on: 611212011 f = + 7xi.. •- Yr*+finre i..aNJ eair+oirh Wrpuaansior� a! � rwrrrrr t ».anawpr.a +rw aau.rrf caaras _' .n'�rwnattmfAr diurpllne�peel,(rd nhurc. APPENDIX B - LABORATORY REPORT E E MAY 2 4 2011 7 TOWN OF VAIL EC Eow AERC)-bic (<OCY LAI'IORATORy D ASSOCIATES, INCORPORATES MAY 2 4 2011 y n cite of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.2323746 www.aerobioloov.net Client Name Street address DS Consulting TOWN pp � � y A DS nsultin Ct TO y I V ®F YAI L => _- / a p�� Date Collected: Date Received: 05/20/11 05/20/11 City, State ZIP Morrison, CO 80465 Non- Fibrous Material Percentage Date Analyzed: 05/21/11 Attn: Steve Shurdiff NVLAP Lab Code 200860 -0 Date Reported: 05/23/11 Client Project Name: The Lodge @ Vail Trace =Less Than 1% ND =None Detected Project ID: 11006180 C 1 1006180 -1B White Tape Job ID: 20% Test Requested: 3002, Asbestos in Bulk Samples 5 Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA- 600/R- 93/116, July 1993. N 20% Sample Identification Physical Description of Sample/Layer Homo- geneous Y/N Layer p Percentage Asbestos Detected Asbestos Percentage Non- Asbestos Fiber Percentage Non- Fibrous Material Percentage Matrix Material Composition Client La Sample Number DWI -1 11006180-IA White Joint Compound N 20% NO Trace =Less Than 1% ND =None Detected 100 C 1 1006180 -1B White Tape N 20% ND 5 11006180-IC Tan/White Drywall N 20% ND 50 11006180 - 1D White Compound w/Multicolored Paint N 40% ND 1 00 G DWI-2 1 1006180 -2A White Joint Compound N 20% ND 100 0 c' 11006180 -2B White Tape N 20% ND 5 11006180 -2C White Compound w/Tan Paint N 20% ND 1 00 c 11006180 -21) Tan/White Drywall N 40% NO I0 90 DWI -3 I I006180 -3A White Tape N 20% ND 95 5 11006180 -3B White Compound w/Tan Paint N 30% ND 100 C Q = Quartz P = Perlite C = Carbonates B = Binder G = Gypsum D= Diatoms M = Mica T = Tar NTR = Non - Asbestiform TR NAC = Non - Asbestiform AC Pagel of 3 A = Amosite AC = Actinolite AN = Anthophyllite CHRY = Chrysotile CR = Crocidolite TR = Tremolite Richard egrzyn Laboratory Analyst Paul Knappe Asbestos Laboratory Supervisor Trace =Less Than 1% ND =None Detected 13949 W. Colfax Ave. Suite 205. Lakewood CO 80401.303.232.3746 Q = Quartz P = Perlite C = Carbonates B = Binder G = Gypsum D= Diatoms M = Mica T = Tar NTR = Non - Asbestiform TR NAC = Non - Asbestiform AC Pagel of 3 d1� AIEROhi4C1;1OCCy "[34:3R^1,"ny F ASSOCIATES, INCOI2PORATEU 1 MAY 2 4 2011 II III Certificate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 _www.aerobiology.net Client Name Street address DS Consulting 5366 Flatrock Ct U U 0 M eo A Date Collected: 05/20/11 Asbestos Percentage Non - Asbestos Fiber Percents a ®WI OF Date Received: 05/20/11 City, State ZIP Morrison, CO 80465 V ' V VV / � VA IL Date Analyzed: 05/21/11 Attn: Steve Shurtliff NVLAP Lab Code 200860-0 Date Reported: 05/23/11 Client Project Name: The Lodge @ Vail Project ID: 11006180 Job ID: Test Requested: 3002, Asbestos in Bulk Samples Method: Polarized Light Microscopy / Dispersion Staining (PLM), Method for the Determination of Asbestos in Bulk Building Materials. EPA- 600/R- 93/116, July 1993. Sample Identification Physical Description of Sample/Layer Homo- geneous Y/N Layer Percentage Asbestos Detected Asbestos Percentage Non - Asbestos Fiber Percents a Non - Fibrous Material Percentage Matrix Material Comp osition Client Lab Sample Number 1 )U' I -3 11006180 -3C White Joint Compound N 50 ND 100 C A = Amosite AC = Actinolite / y AN = Anthophyllite CHRY= Chrysotile CR = Crocidolite TR = Tremolite R ichard egrzyn Paul Knappe Trace =Less Than I% Laboratory Analyst Asbestos Laboratory Supervisor ND =None Detected 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 Q = Quartz P = Perlite C = Carbonates B = Binder G = Gypsum D= Diatoms M = Mica T = Tar NTR = Non - Asbestiform TR NAC = Non - Asbestiform AC Page 2 of 3 INCC7 C��MI ficate of Analysis 13949 W. Colfax Ave Suite 205 Lakewood, CO 80401 303.232.3746 www.aerobioloov.net DS Consulting L MA 2 /j 20 �, + I Date Collected: 05/20/11 5366 Flatrock Ct � a Date Received: 05/20/11 Morrison, CO 80465 �p�p' Lf� Date Analyzed: 05/21/11 Steve Shurtliff V V 1 V OF 'AIL NVLAP Lab Code 200860 -0 Date Reported: 05/23/11 Client Project Name: The Lodge @ Vail _� Project ID: 11006180 Job ID: General Notes ND indicates no asbestos was detected; the method detection limit is 1 fiber. Trace or " <V indicates asbestos was identified in the sample, but the concentration is less than 1 %. ♦ All regulated asbestos minerals (i.e. chrysotile, amosite, crocidolite, anthophyllite, tremolite, and actinolite) were sought in every layer of each sample, but only those asbestos minerals detected are listed. Amosite is the common name for the asbestiform variety of the minerals cummingtonite and grunterite. Crocidolite is the common name used for the asbestiform variety of the mineral reibekite. ♦ Tile, vinyl, foam, plastic, and fine powder samples may contain asbestos fibers of such small diameter (< 0.25 microns in diameter) that these fibers cannot be detected by PLM. For such samples, more sensitive analytical methods (e.g. TEM, SEM, and XRD) are recommended if greater certainty about asbestos content is required. Semi - quantitative bulk TEM floor tile analysis is accepted under the NESHAPS regulations. ♦ These results are submitted pursuant to Aerobiology Laboratory Associates, Inc.'s current terms and conditions of sale, including the company's standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which the results are used or interpreted. ♦ Unless notified in writing to return the samples covered by this report, Aerobiology Laboratory Associates, Inc. will store the samples for a minimum period of thirty (30) days before discarding. A shipping and handling charge will be assessed for the return of any samples. ♦ Aerobiology does not gaurantee the reuults of tape lifts, microvacs, wipe, and /or debris samples. Accurate analysis cannont be preformed due to particle size, media used, and /or amout of material given. Analysis of these materials should be preformed by a TEM. A result of ND does not indicate that the sample area does not contain. It means the analyst could not identify asbestos in the specific sample for the reasons listed above. Notes Reauired by NVLAP ♦ This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. ♦ This test report relates only to the items tested or calibrated. ♦ This report is not valid unless it bears the name of a NVLAP- approved signatory. ♦ Any reproduction of this document must include the entire document in order for the report to be valid. 13949 W. Colfax Ave. Suite 205, Lakewood CO 80401, 303.232.3746 06 -06 -2011 Inspection Request Reporting Page 20 4:39 pm Vail, CO - City Of Requested Inspect Date: Tuesday June 07, 2011 Site Address: 174 E GdRE CREEK DR VAIL LODGE AT VAIL BALLROOM CLOSET A/P /D Information Activity: B11 -0141 Type: COMBO Sub Type: ACOM Status: ISSUED Const Type: Occu ancy: Use: Insp Area: Owner: LODGE PROPERTIES INY Contractor: BLU SKY RESTORATION CONTRACTORS INC. Phone: (303) 789 -4258 Description: WATER AND MOLD MITIGATION SERVICES PERFORMED IN CLOSET OF BALLROOM. Inspection Hi story ' Item: 60 BLDG - Sheetrock Nail Requested Inspect o ts1 Item: 50 BLDG - Insulation Item: 30 BLDG-Framing Requested Time: 12:00 PM Requestor: BLU SKY RESTORATIO NTRACTORS Phone: (303) 789 -4258 INC. Comi'nents: 331 -1782 Assigned - JMONM ON Entered By: JMONDRAGON K Action: Time Exp: r` Item: 5 DG- Insulation Requested Time: 11:30 AM Requestor U SKY RESTORATION CONT ACTORS Phone: (303) 789 -4258 INC. Comments: 1 -1782 Assigned To: J DRAGON Entered By: JMONDRAGON K Action: Time Exp: REPT131 Run Id: 13180 Inspection Hi story I Item: 60 BLDG - Sheetrock Nail Item: 50 BLDG - Insulation Item: 30 BLDG - Framing Item: 90 BLDG -Final REPT131 Run Id: 13180