HomeMy WebLinkAboutLions Ridge Filing 1 Block A Lot A5 Lions Mane Unit 601.PDF DOM
Edge of deck ro
I: Cm-,
Deck 12
A—i Building line below L&M
Building line above --=--��_��, rt I
Basebd
Basebd _
1>
a.
Closet
Bedroom 1• ( _
Phone
C�,
Plate above Phone
Master Bedroom
Alarm
Thermo hermo
I
C r1t) Roof
Heater t—
H
C, Bath 2 Thermo
P"
Bedroom 2
fan If, in
F_�", Heater 1-Master"'I
Heater Bath I
A
Panel CH Bath ("T LT—V t
_J Plate
SD fan
Water
0 Down l f Up
Down - up
Existing windows above Building line below
M
up fan '
Down
Cinht
W Down g I.ig
D
P a
Up
inel f=
Humid Junct Gnll above 'I
above Laundry #Plate
Thermo
Dining , Open to Living below
c :
Humid. 2
Micro E 0
Ref. M I I I , Roof
1 E E E Thermo
t�l I a) 0) a) I I I LLJ
CC
Plate a I t)
'I C)
above c Ca U l,
ll'-
F_
Kitchen OQ>) 0 E W
Dis
DW p I P11 le LivinglRoom
Building line below
WP
Deck
Beam line'to remain
14 11—T
Beam line to remain
WP '
> > > Deck below
0 . 0
E E E
Edge of deck
Basebd Building line below
Down -4
Roof edge, typ
7-
Shaded areas indicate existing
construction to be removed, typ.
Roof edge, typ.
ea
-01
TING 7E7R7LE7V7EL: 1�/41 -0
s777
EXISTING MIDDLE LEVEL 1/4 =1 31- EXISTING UPPER LEVEL 1/41
1
EXISTING LOWER LEVEL NORTH 2 .
In the case of remodel work or new additions to existing construction, exterior
GENERAL NOTES finishes, detailing, materials,etc , are to match existing or as selected and • rjv ot
approved by the Owner and approved by the Town of Vail Design Review Board
Contractor is to visit the site, verify existing conditions, including utility locations,
Contractor to verify existing conditions and systems, including required I Z
hookups and stubs, and familiarize himself with all new work Intheeventof 171
ventilation, relocated heating elements, spa construction and equipment, etc , Z
discrepancies between the drawings and existing conditions, notify the Architect
and determine adaptability tc new work. Field verify with the Owner all existing
2
before proceeding with the work All work to be performed in accordance with all windows/doors to be reused in exist construction or relocated to the new work.
applicable codes and regulations
The Contractor shall remove from the site and dispose of all demolition The Architect assumes no responsibility for errors, omissions and applicable
materials, debns and rubbish as soon as practicable Protect all existing areas code requirements of consul ants The Architect assumes no responsibility for
from the new work and repair all damaged work that is to remain The building utility coordination, care of adjacent properties, performance specifications ands"""""`'
and grounds shall be kept clean at all times. the components of constructor safety, or for the Contractors failure to carry out NOTE: Unit 301 shown, Unit
Interior detailing finishes and materials, including material and performance the work in accordance with[he Construction Documents. 601 similar but opposite hand.
specifications, as selected and approved by the Owner. These include, but are The investigation of hazardous materials is beyond the scope of these
not limited to, floor finishes, doors, hardware, trim, stairway handrails, closet Architectural Services. The Dwner shall be responsible for all existing hazards Permit set 7-12-04
on the property; and for the discovery, presence, handling, removal or disposal Peel/Laa=walter.Architeds. LL _Q
systems and shelving, fireplace mantels and hearths, built-in furnishings, of or exposure of persons to hazardous materials, waste or substances in any David Mark Peel, A I A Kathy Langenwalter, A I A
cabinetry, appliances, plumbing fixtures, bathroom accessories, lighting fixtures form on the property, including, but not limited to, radon gas, asbestos, asbestos Lions Mane Condominiums
and trim, sound and security systems. Provide blocking as required for proper rt products, etc P.O. Box 1202 Vail, Colorado 81658 date
installation of these items Sound insulate the floor system and interior walls as Phase 1 — Unit Remodels 0
determined by the Owner Tele 970-476-4506 Fax 970-476-4572 project
Ownership and possession of the original Architectural drawings shall remain Lot A5-1 , Lions Ridge Filing 1 -
Mechanical and electrical systems design shall be the responsibility of the that of the Architect Reprotucible copies will be provided at the Owners 1116 Sandstone Drive, Vail, CO Al
General Contractor, required subcontractor or others as selected by the Owner. request and expense. These drawings are not to be used on other projects
Coordinate any required dropped or soffited ceiling areas with the Architect prior except on agreement in writng and with appropnate compensation to the sheet of
Architect.
to the start of the framing phase of construction
i
I
i
I
NO n 01 filar but
op i an s ew t d C
is o e a casemen ndo�
+ Edge of deck '
I
i 4
t Deck dow
Building line above
_ Building line below
_t::tF_ 4=t '
Closet +
i I Relocated existing door from
' I I Bedroom middle level deck access 1
Swing new door into closet per Owner — - - I i
I 1 fi ! I
LLic ,-,-New C @11tH aCC2SS panel as
Swing new door against 9 p -- - F
' existing wall. Relocate r required to existng water htr. -,Vz-- New 2468 pocket door 2 {
light switch per electrical.
Solid wall to top of backsplash- - -�
height. Glass black above to
-` � s existing ceiling keight Remove Master Bedroom ROOF t !
- NOTE: Electrical layout/design by others, typ. ` I t exiexistin space heater and ceiling Master +
Bedroom 2 9 P g !
1
All work per applicable codes and regulations. �_��" �,- i� Bath 2 light/exhaust far as required. Bat 4 i
i I Bath 1 i New 2068 glasspanel door - , ` �-
'
Down U `riled shower with frameless sliding glass
` i , _ P Existing windows above doors Verify shower location and �� 1;
02� _ _ fY _ Building line belo�rr i
tiled bench confi uraton with Owner.
Owner O
B t i / 1
uilt-ins per wn ' � , � a � --
D W Down -_
� ,� Solid Wall with wood cap to ' '°� \ � � �i -- Dawn
U I handrail height this section
__4 _A_ _L , - ____ �4 -
I
New 2468 min. r� 'N E: New proxi ately 24" 6" h ��
_ j ' east-fac em ow in Unit 601
Bi-fold door � � '
Newsheetrockfinish -----� en to Livin below
over existing brick �� ; �1'�`-- g (similar p ite
z I a io with ner and roof clearance. -----« existing nin
as c os
r Micro �� posse o xisting bat
-- — --- ; Remove wall sections and replace--
`� nfy hei with Owner
with open handrail per Owner and I
f
�\ 1 applicable code. Maintain bearing
t _} Kitchen �`op ,/ sections as required. Field verify. `�� \ 1
+ Dbl sink/ �Go° ,( //
i Disposal �� Q '
NOTE: Kitchen cabinetry/appliance o� r Q ` Living Area j
y Roof
design layout by others. Maintain
-`
adequate clearances per Owner. D `"' � o remain 4
w q p 111 ,' Existing brick t i
'Structural post to remain
Rfin9 Dining
' (t =- Operable venting skylights (2)
De_ ck -
Beam line to remain
Relocated existing door - �\ -
from Bedroom 2 -i�---- Existing wall line
to be removed � � � ,� �- --- Continuous sheetmetal flashing
from skylights to existing fascia
Skylights above (2) I
Building line below
Building line below �-
Il 1 __ _ _____� _ ___ ________ __� f 1
Down -fi- New roof edge typical
�b Roof edge, t
_ ` Shaded areas indicate
F new construction, typ.
Roof edge, typical: Remove existing decking this section.
• Raise new floor to match existing
REVISED LOWER LEVEL 1/4"=�'-0" � REVISED MIDDLE LEVEL 114"=��-0" REVISED UPPER LEVEL 1�4"=x`-01
• � TH
1 NoR
�p�n�nfrq��
og Cato,,,,,s�o
°°°,c'Q. ✓ 000
s
RK
PEEIv °
C-16 2
DA
NOTE: Unit 301 shown, Unit
r
601 similar but opposite hand.
s
Peel/Lanaenvyalter Architects. L.L.C. permit set 7'-'12-04
Lions Mane Condominiums David Mark Peel, AA A Kathy Langenwalter,A I A
Phase 1 - Unit Remodels P.O. Box 1202 Vail, Colorado 81658 date
i LOt A5-1 Lions Ridge Filing � Tele 970-476-4506 Fax 070-476-4572
� g project
A2
1116 Sandstone Drive, Vail, CO
Unit d'aw'n
sheet of