Loading...
HomeMy WebLinkAboutB11-0159TRANSMITTAL FORM Revision Submittals: 1. "Field Set" of approved plans MUST accompany revisions. 2. No further inspections will be performed until the revisions are approved & the permit is re-issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Permit #(s) information applies to: ���� Attention: � O Revisions � �` 1^ /� () Response to Correction Letter � ���' \ attached copy of correction letter - ,e �� � \ v v�.� �\ Q_ p���1�� ( ) Deferred Submittal 'C T�.J '( Yv �••J �Other Project Street Address: �L� � �lN-2, (�X.PSLIG�OiL -J �JZ� (Number) (Street) Building/Complex Name: Contact Information: Company: (Suite #) Company Address: �� City: v'�C �� State: UJ Zip:_��_ Contact Name: � ��� Contact Phone: `� 0 a�-f � l.Ji'�� 1 E-Mail �� � JI(�-�t� � If�.� j , �--�J�(`^- Revised ADDITIONAL Valuations (Labor 8� Materials) (DO NOT include original valuation) Building: Plumbing: Electrical: Mechanical: Total: $ � �- • � r .- l�� � `� l� ( . ► i � � � ' r �� , � e, _ � ��� u�zZ( v�- � � � Z3 Z �U� U��� �' � ..� SZ Z (use additional sheet 'rf necessary) __._.... _.... __..... Date Received: 1 ECEIVE SEp 0 2 2011 TO_WN_OF VAIL O1-Jan-10 T. Boyle Engineering, Inc. 1650 Fallridge Road, Unit C-2 Vail, Colorado 81657 Mike Suman Suman Architects 141 E. Meadow Drive, Suite 211 Vail, Colorado 81657 Field Report The following items were observed: The framing for this remodel is complete at this time. Date: 08/11l11 Project: Orr Remodel Location: Vail, Colorado Contractor: SRE Builders Owner: The Orr's Weather: Partly Cloudy, 75 deg Present at Site: Steve Elicker Tim Boyle I have deternuned that this framing has been completed per the plans and specificadons issue by this office on May 31, 2011, with a couple of modificarions that have been coordinated between Steve Elicker and myself during the construction process. Feel free to give me a call if you have any questions or comments regarding this report. Respectfully T. B ENGIN� Timothy . o le, P President Cc: Steve Elicker - SRE Builders p ���oM� SEP 0 2 2011 TOWN OF VAIL NOTE: THIS PERMIT MUST BE POSTED ON JOBS/TE AT ALL TIMES � .� �mw��o� v�3 � Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 COMBINATION BLDG PERMIT Permit #: B11-0159 Job Address: 174 E GORE CREEK DR VAIL Location......: LODGE AT VAIL UNIT 522 & 523 Parcel No....: 210108281001 OWNER LODGE PROPERTIES INC 06/02/2011 IN CARE OF C/O FIXED ASSETS DEPT 390 INTERLOCKEN CRESCENT STE 1000 BROOMFIELD CO 80021 APPLICANT LODGE PROPERTIES INC O6/02/2011 IN CARE OF C/O FIXED ASSETS DEPT 390 INTERLOCKEN CRESCENT STE 1000 BROOMFIELD CO 80021 CONTRACTOR SRE BUILDERS, INC. 06/02/2011 PO BOX 6376 VAIL COLORADO 81658 License: 360-A Phone: 81657 Phone: 81657 Phone:(970)845-6359 Description: COMBINE UNITS 255 & 523 TOGETHER VIA UPPER FLOOR. RELOCATION OF KITCHEN 8� POWDER ROOM ON LOWER LEVEL. DELETE ONE BATHROOM AND RELOCATE A BATH QV 2ND FLOOR. RECONFIGURE THE TWO MASTER BATHS ON 2ND LEVEL. RELOCATE STAIRS. ADD ERV + 3 AIR CONDITIONING UNITS. ADD 1 GAS FIREPLACE. CHANGE HEAT TO RADIANT FROMBASEBOARD. Occupancy: Type Construction: Project #: Applied.....: Issued. . . : PRJ11-0225 06/02/2011 06/27/2011 Valuation: $460,000.00 ....................,,,.........,xx........,,,,x,..,.....,...,...>.,....._.....,,,... FEE SUMMARY ,.,..,..x,,.......,.<.,.»,,.«.....,........,,...,....,..x.,,.....,.,.....«...,.. Building Permit -----------> $3,009.75 Bldg Plan Check ----------> $1,956.34 Use Tax Fee-----------------------> $9,000.00 Electrical Permit ---------> $345.00 Elec Plan Check -----------> $224.25 Restuarant Plan Review--------> $0.00 Mechanical Permit ------> $1,100.00 Mech Plan Check ---------> $275.00 Additional Fees--------------------> $0.00 Plumbing Permit --------> $1,275.00 Plmb Plan Check ---------> $318.75 Recreation Fee--------------------> $11.00 Investigation-----------------------> $0.00 Will Call------------------------------> $20.00 TOTAL PERMIT FEES-------------> $17,535.09 Payments------------------------------> $17,535.09 BALANCE DUE-----------------------> $0.00 .............«.......,_._..,,........._.._..,.....«,_.,,.,.......,,_..,.....,.,.__,..«.......,..........,.,....»....,.><._,,.........,x,...........,........,.,..,.»....,....,......... DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 A - 4:00 P ;� na ure of H l I.CJ . Prir combination permit_012811 c� �Z� C Date , � T��W� (�F V� � � .,..,,..� ...............................��...�........,,,,......,.......x.x,,..,�........,......,,,,.,,,,.......,,,..,......,..........x,...,........,.......,.........x..,.,,....... CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF Permit #: B11-0159 Owner: LODGE PROPERTIES INC LODGE AT VAIL UNIT 522 & 523 Address: 174 E GORE CREEK DR VAIL Location: ................<x...,,.,,..........,....,.....,.,..x,,,,.,,..,.,.....,....,........,...........,...,....,.<.<..x..,..,..........x.,,.>...,,.........,,...,.,,.....,,,>.,.,..<.....,>., combination permit_012811 i _..: � ��� �� ��� a ********«****************«««*,t+*+r********,r«+**+e***««,r«**r.r«*****«*.+++*******w++r.*,t,t*****«..+****«***+***�*******.*r*****t*******,+,+++r***««,t.+*****w REQUIRED INSPECTIONS AND STATUSES Permit #: 611-0159 Owner: LODGE PROPERTIES INC LODGE AT VAIL UNIT 522 & 523 Address: 174 E GORE CREEK DR VAIL Location: *******«*********«********�********************************,.*****************.**********„**********«***.*******************************,.***«*,,.****** Item: 00120 ELEC-Rough Item: 00200 MECH-Rough Item: 00220 PLMB-Rough/D.W.V. Item: 00240 PLMB-Gas Piping Item: 00230 PLMB-Rough/Water Item: 00030 BLDG-Framing Item: 00050 BLDG-Insulation Item: 00060 BLDG-Sheetrock Nail Item: 00190 ELEC-Final Item: 00290 PLMB-Final Item: 00390 MECH-Final Item: 00090 BLDG-Final combination permit_012811 ***********************�******+************************************************************* TOWN OF VAIL, COLORADO Statement ******************************************************************************************** Statement Number: R110000704 Amount: $15,578.7506/27/201102:56 PM Payment Method: Check Init: SAB Notation: 5204 SRE BUILDERS ----------------------------------------------------------------------------- Permit No: B11-0159 Type: COMBINATION BLDG PERMIT Parcel No: 2101-082-8100-1 Site Address: 174 E GORE CREEK DR VAIL Location: LODGE AT VAIL UNIT 522 & 523 Total Fees: $17,535.09 This Payment: $15,578.75 Total ALL Pmts: $17,535.09 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code BP 00100003111100 EP 00100003111100 MP 00100003111100 PF 00100003112300 PP 00100003111100 RF 11100003112700 UT 11000003106000 WC 00100003112800 Description BUILDING PERMIT FEES ELECTRICAL PERMIT FEES MECHANICAL PERMIT FEES PLAN CHECK FEES PLUMBING PERMIT FEES RECREATION FEES USE TAX 4% WILL CALL INSPECTION FEE Current Pmts 3,009.75 345.00 1,100.00 818.00 1,275.00 11.00 9,000.00 20.00 ----------------------------------------------------------------------------- r*****r**�*+*****+**************«********************+*******�*****+******+**:************** TOWN OF VAIL, COLORADO Statement ***�***********�**************************+*+**************+*************+**.*****++******** Statement Number: R110000588 Amount: $1,956.34 06/02/201104:40 PM Payment Method:Credit Crd Init: SAB Notation: VISA-STEPHEN ELICKER (SRE BUILDERS) ----------------------------------------------------------------------------- Permit No: B11-0159 Type: COMBINATION BLDG PERMIT Parcel No: 2101-082-8100-1 Site Address: 174 E GORE CREEK DR VAIL Location: LODGE AT VAIL UNIT 522 & 523 Total Fees: $17,524.09 This Payment: $1,956.34 Total ALL Pmts: $1,956.34 Balance: $15,567.75 *****************************��***********************+*****************+******************* ACCOUNT ITEM LIST: Account Code -------------------- PF 00100003112300 Description Current Pmts ------------------------------ ------------ PLAN CHECK FEES 1,956.34 ----------------------------------------------------------------------------- BUILDING PERMIT APPLICATION (Separate applications are required for alarm & sprinkler) Project Street Address: /�y �'._G�,z� C��Erc�2, ��� (Number) (Street) (Suite #) Building/ComplexName: .Lc�1�C..>� AT �/a.LL Contractor Information Business Name: -P�� l3t.��L !J �.J2S � �- Business Address: �� � �x �3 � � City �%,o, �. L State: C c� Zip: v t CoS � Contact Name: .fi'F ✓F f�£cicE�. Contact Phone: �9 �v) 3�L - 1S3i. Project #: DRB #: �� /� II U ! % i Building Permit #: ��(�� 5 Gf Lot #: Block # Subdivision: Work Class: New ( ) Addition ( ) Alteration (� ) Type of Building: Single-Family ( ) Duplex ( ) Multi-Family � Commercial ( ) Other ( ) Work Type: Interior (�() Exterior () Both () Contact E-MaiL• _S�!'-�,/f �' ���.(Sul-L,��iZS, �on-� Contractor Registration Number: -��U ,q Electrical X � ���� � Mechanical Owner%Owne�Representative Signature (Required) Plumbing Project Information`1� OwnerName: JY�� /�vbSntJ U� %�t.�.S'�" Parcel #: _�t � � �" V`�2 - `���o - � (For Parcel #, contact Eagle County Assessors Office at (970-328-8640 or visit www.eaglecounty. us/patie) Valuation of Work Included Plans Included Work (X )Yes ( )No (x)Yes ( )No o � � (>c)Yes ( )No (X)Yes ( )No � 5, � �� ( x )Yes ( )No ( x )Yes ( )No g; �� (�)Yes ( )No (X)Yes ( )No .� �� Value of all work being performed: $�{��pUC7 �value based on IBC Section 109.3 & IRC Section 108.3� Electrical Square Footage �000 Detailed Scope and Location ofWork: �c�M.3'�n��v� LN��i �' S��n.ro �2� i�eG���.0 (/�r� _ L�.�P�,�_ �'�uc�fZ �£Cc7CAi�v� v r ,L-°�Gia �..J . �' l�nwOc`� .�� �h or,� �-OWE� /� z V� L, 1 J� L E�`r- C7+� � i�J,ac�,� ��.-.—, 'A R?/O /�ELcSG!-5'► f .� i_�aT4a vr� �'� !' �-a � iZ _. K� � � r,i 5 i-�u-.e � �-1� %cv v �-�%� �KS c�..J �✓�a � F tiJ �.L.� �� C tXP4 �� (use additional sheet if necessary) � J� � V t 3 A�- C Ur✓O�'i�vJ�ivl"� �t�lt/L/.S. �J� % C3a.s ���C�4C� . C'k�A�� �� i�.2 S , /-1� I� %�f1kkT TJ L�i✓T �i['U ih ��/b.Si 6oI�� � For Office Use Only: Date Received: FeePaid: 5 ° ������72 Received From: ; —� D U L5 Cash Check # C Visa MC Last 4 CC # l�`�3 exp date: 13 JUN 0 2 2011 Auth # -�t��i TOW� n� :,F��� -Jan-I1 State of Colorado Asbestos Testing & Abatement Requirements Asbestos testing and abatement protects workers, homeowners, neighbors and emergency services responders from ex- posure to harmful asbestos. It is your responsibility to be in compliance with the State. Please contact the State directly for their requirements at the contact info listed below. When is asbestos testinq reauired? ANY building projects disturbing more than these threshold levels of building materials require asbestos testing: One- and Two-Family Dwellings: 32 square feet All Others (commercial spaces, hotel rooms, etc): 160 square feet Definition of a single-family dwelling: any dwelling unit that is used primarily for a single family, including multi-family/condominium units, and fractional fee units. Asbestos testing results must be provided with your application for a building permit. Tests which identify POSITIVE results at more than 1% require abatement by a State-certified abatement contractor. The air clearance letter or form must be submitted to the Town of Vail before the building permit will be issued. Project Checklist My project falls into the category checked below: � Will not disturb more than the threshold limits identified above. � Tested negative, or at 1% or below (1 copies of test results included) � Tested positive at more than 1%, requires abatement (1 copies of test results included) Tips & Facts: • Even recent construction projects may include asbestos-containing materials, so buildings of a� age require testing. • The "1989 Ban" on asbestos-containing materials is commonly misunderstood. "In fact, in 1991 the U.S. Fifth Circuit Court of Appeals vacated much of the so-called "Asbestos Ban and Phaseout" rule and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos-containing product categories was set aside and did not take effect." - CDPHE Asbestos test results should be submitted to: Town of Vail, Community Development, 75 S Frontage Rd, Vail, CO, 81657. Town of Vail Contact: Fire Prevention Bureau Vail Fire Department 75 S Frontage Rd Fire_inspectors@vailgov.com 970-479-2252 www.vailgov.com State of Colorado Contact: Colorado Department of Public Health and Environment Asbestos Compliance Assistance Group 303-692-3158 asbestos@state.co.us www.cdphe.state.co. us O1-Jan-11 ���. Phone (303) 763 9639 G � H E RRO N� Enterprises USA, Inc. Fax (303) 763 9686 E-Mail Lerrnie.Herron@comcast.net �� Hazardous Materials*Mold*Asbestos*Lead Paint Website www.HERRON-Enterprises.com Environmental Services*Industrial Hygienists 7267 W. Hampden Ave. Lakewood, Colorado 80227-5305 May 13, 2011 SRE Builders/Ms. Sarah Wyscarver HERRON� Project No.: 0502114 Job No.: Verbal Location: Unit 523,174 E. Gorecreek Ct., Vail, CO 81657 Date(s) of Service: May 04-12, 2011 Services Requested: Environmental Consultation/I,imited Asbestos Scope of Work Per your request, and under the guidelines defined, HERRON� Enterprises USA, Inc. (HERRON�) has concluded the Environmental Consultation/Limited Asbestos Building Inspection at the aforementioned property. Local, state and/or federal regulations, including but not limited to the Air Quality Control Division (AQCC) Regulation 8, OSHA 1926.1101, and EPA (NESHAP) 40 CFR Part 61 may require a comprehensive asbestos inspection priar to a renovation ar demolition. This inspection requires an AHERA and State certified asbestos building inspector identifying and sampling any friable and non-friable asbestos containing materials which could be affected by the activity. HERRON� was contracted by the Client, to perform: Unit 523,174 E. Gorecreek Ct., Vail, CO 81657 a. Limited Asbestos Building Inspection is intended to confirm Environmental Hazards, specifically Asbestos- Containing Materials; i. Unit Drywall; ii. 5 Day Turnaround PLM Analyses; iii. It was expressly advised that although this is a Limited Asbestos Building Inspection, it is comprehensive to the aforementioned materials. Only materials impacted requiring response actions have been instructed and authorized by the Client. Under the protocol of limited sampling whereas not `all' suspect materials outside of the response action areas were sampled, under local, state and/or federal regulations, including but not limited to AQCC Regulation 8 (State), 29 CFR 1926.1101 (OSHA), 40 CFR Part 61 EPA (NESHAP), and 40 CFR 763 EPA (AHERA), a certain protocol for sampling, number of samples obtained, and assessment is required; HERRON� was subsequently contracted by the Client, to perform: Rush Turnaround PLM Point Count Analyses. HERRON` Project No. 0502114, Limited Asbestos Page No. - 1 Building Inspec[ion �81 I - 0�� 9 May 13, 2011 , � � G° - � H E RRO N� Phone (303) 763 9639 Enterprises USA, Inc. Fax (303) 763 9686 E-Mail Lennie.Herron@comcast.net '�� Hazardous Materials'Mold*Asbestos*Lead Paint Website www.HERRON-Enterprises.com Environmental Services*Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305 Conc[usion Based on the information generated by this report, HERRON� concludes that the aforementioned property does not have Regulated Asbestos Containing Material(s) (RAC1Vn, for purposes of a renovation or demolition (when conducted in accordance with local, state and/or federal regulations), per the following: In order to comply with local, state, and/or federal regulations, the following Asbestos Containing Materials, or assumed Asbestos Containing Materials will have to be removed if they will be made friable during a renovation or demolition (typically floor tile/mastic, roofing materials, window putty (dependent on pliability), etc., are normally demolished with the structure, if conducted in accordance with local, state and/or federal regulations, however, require removal during a renovation): Materials that contain <=1.0% Asbestos are not considered Asbestos Containing Materials by NESHAPS or EPA but may still be covered by OSHA. OSHA regulations may apply during potential disturbance activities. Although a material may have been determined to contain <=1.0% Asbestos, or during a demolition, if the composition of drywalUjoint compound (when the joint compound does not cover the entire surface) has been determined to contain <=1.0% Asbestos, this document serves as a Hazard Communication and should be followed during an activity such as a renovation or demolition, to ensure that an exposure does not occur. The Maximum Allowable Asbestos Level (MAAL) may not be exceeded at `any' time in accordance with local, state, and/or federal regulations, including but not limited to AQCC Regulation 8(State), 29 CFR 1926.1101 (OSHA), 40 CFR Part 61 EPA (NESHAP), and 40 CFR 763 EPA (AHERA). Suspect materials which were sampled and determined to contain <=1.0% Asbestos (refer to Attachments), by PLM and/or PLM Point Count analysis are: White Drywall/Joint Compound, Walls and Ceilings, Surfacing Material (S), <5,000 SF, Good Condition (Current Condition), Non-Friable, throughout Unit, 5 Sample(s), 050411-2A, ls` Floor Level, Bedroom, N Wall, 5' from Floor, 2' from E Wall 050411-2B, IS` Floor Level, Bedroom, 5' from Floor, at SW Corner 050411-2C, 2"d Floor Level, Bedroom, N Wall, 5' from Floor, 5' from W Wall 050411-2D, 2"d Floor Level, Bedroom Closet, W Wall, 5' from Floor, 3' from N Wall 050411-2E, 2"d Floar Level, Main Room,S' from Floor, at NW Corner (point count) Suspect materials which were not visible/accessible at the time of the inspection were: 1. `All' EPA suspect Materials not requested. 2. `Any' confirmed or suspect ACM which may have been concealed at the time of the inspection. 3. During a normal inspection, and more specifically when non-destructive sampling techniques are employed, it is not within the scope of the inspection to remove surface materials to inspect the structures and/or materials which may be under the surface, i.e., within or under concealed areas such as under carpet, under sub-floors, within chases, walls, crawlspaces, tunnels, etc., to remove suspect Asbestos Containing Material(s), to move and/or sample electrical wiring which has not been 'locked out', etc. All said areas are to be assumed as containing >1.0% Asbestos, until such a time that these areas are made accessible, and/or rendered safe so that sampling can be performed. 4. HERRON� recommends. extreme caution during a renovation or demolition of these areas in the event that an area which was not suspect, visible, accessible and/or specified during the inspection, is discovered to contain or is suspected of containing an Asbestos Containing Material (ACM). Under local, state and/or federal regulations, should such an event occur, the Client and or Contractor is required to cease operations which may effect this (these) material(s) until an inspection is concluded and a determination is made by an AHERA and State Certified Asbestos Building Inspector. HERRONt Project No. 0502114, Limited Asbestos Page No. - 2 May 13, 20l l Building Inspection '� ��► � Phone (303) 763 9639 G � H E RRO N Enterprises USA, Inc. Fax (303) 763 9686 E-Mail Lennie.Herron@comcast.net '�� Hazardous Materials*Mold*Asbestos*Lead Paint Website www.HERRON-Enterprises.com Environmental Services'Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227-5305 5. It is expressly advised that although this is a Limited Asbestos Building Inspection, it is a limited inspection which is designed to indicate the presence of Asbestos Containing Materials in the Building(s), and under normal the guidelines defined, specific samples and locations have been instructed and authorized by the Client. Although some materials may indicate that Asbestos is not present in this report, and under the protocol of limited sampling whereas not `all' suspect materials were sampled, under local, state and/or federal regulations, including but not limited to AQCC Regulation 8 and OSHA 29 CFR 1926.1101, a certain protocol for sampling, number of samples obtained, and assessment is required. 6. Disturbance of these areas could create a potential health hazard. Suspect materials which were visually inspected and determined to be Non-ACM materials at the time of the inspection were: Not applicable. Inspection Methodology: HERRON� selected sample locations and frequency of sampling based on observations, Client requirements and/or the assumption that like materials in the same area are homogeneous in accordance with EPA Publication EPA 560 / 5-85 - 030a `Asbestos in Buildings: Simpliiied Sampling Scheme'. Recommendations As Regulated Asbestos Containing Materials were not discovered during this inspection, further action is not required. Should a renovation or demolition occur which would affect materials that were not homogeneous to the materials which were inspected and determined negative for Asbestos, HERRON� would recommend as a minimum Plan of Action: 1. Comprehensive Asbestos Building Inspection: a continuous process in areas which may not have been accessible, or for materials which may have been concealed in previous inspections, may be required, i.e., review and usage of previous Asbestos Inspection(s), identification of suspect materials, friable and non-friable, approximate quantities (ACM), discovery sampling in areas which will be affected by the renovation/demolition in order to determine the presence of Asbestos Containing Materials (ACM), etc. Assumptions, and Limitations This Environmental Consultation is applicable in whole, not in part, to the entire contents of the document, and the assumptions, and limitations of current published Terms of Services. HERRON" Project No. 0502114, Limited Asbestos Page No. - 3 May 13, 201 I Building Inspection ���► � Phone (303) 763 9639 G � H E R RO N Enterprises USA, Inc. Fax (303) 763 9686 E-Mail Lennie.Herron@comcast.net �� Hazardous Materials*Mold*Asbestos*Lead Paint Website www.HERRON-Enterprises.com Environmental Services*Industrial Hygienists 7261 W. Hampden Ave. Lakewood, Colorado 80227-5305 Closure Information and data which has been generated as a results of this Environmental Consultation will remain confidential and will not be released to any party without authorization from Client(s). HERRON� Enterprises USA, Inc. appreciates the confidence which has been demonstrated by your continued patronage, and look forward to assisting you and your group should you have future needs of Environmental Consultation. Sincerely, Sincerely, Billie J. Herron-Lusk Project Manager HERRON� Enterprises USA, Inc. Certifed Asbestos Building Inspectors(s): Billie J. Herron-Lusk (Project Manager), and Dillon Carson HERRON� Project No. 0502114, Limited Asbestos Page No. - 4 May 13, 2011 Building Inspection ���� � E�O � H E R RO NO Enterprises USA, Inc. Phone (303) 763 9639 ��r Fax (303) 763 9686 1 Hazardous Materials*Mold*Asbestos`Lead Paint E-Mail Lennie.Herron@comcast.net Environmental Services*Industrial H ienists Website www.HERRON-Enterprises.com 7267 W. Ham den Ave., Lakewood, Colorado 80227-5305 ?:� � �z� � 2B __. t ( u# � m, �� , �� ;� *< < Limited Asbestos Building Inspection, Attachments 2E '--� ;� � � � � � � . f: pE� �-�►e ReSe/`VO%l5 E/7VII"0/7177e/7tc�/, May 12, 2011 Laboratory Code: RES Subcontract Number: NA Laboratory Report: RES 212279-1 Project # / P.O. # 0502114 Project Description: None Given Lennie Herron Herron Enterprises, USA, Inc. 7261 W. Hampden Ave. Lakewood CO 80227 Dear Customer, /nc. Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. RES 212279-1 is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Sincerely, . J` � ' -' - - — -- -�--rt -�c- �-_���✓` ��-_-- Jeanne Spencer Orr President �i"% �`/ �-� — Analyst(s): % Paul D. LoScalzo Wenlong Liu Michael Scales Adam Humphreys Anita Grigg Robert R. Workman Jr. Bethany Nichols P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 1 of 2 1-866-RESI-ENV www.reilab.com RESERVOIRS ENVIRONMENTAL, INC. NVLAP Lab Code 101896-0 TDH Licensed Laboratory # 30-0136 TABLE PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME RES Job Number: Client: Client Project Number / P.O Client Project Description: Date Samples Received: Analysis Type: Turnaround: n..i„ n.,��.,�or1• RES 212279-1 Herron Enterprises, USA, Inc. 0502114 None Given May 4, 2011 PLM, Short Report 5 Day Mav 11 _ 2011 Page 2 of 2 vuav . .. �...��..... ----. . ien a L „ .e _ � .. on on- Sample ID Number A Sub Asbestos Fibrous Number Y Physical Part � Fibrous Components E Description (%� Mineral � visuai omponents (%) R ; Estimate (% % 050411-2A EM 734942 A Gray resinous material wl cream paint 8 ND 0 100 B White paint w/ white texture 10 ND 0 100 C White/tan drywall 82 ND 20 80 050411-26 EM 734943 A Tan mastic TR ND 0 100 B White compound w/ white paint 10 ND 0 100 C White compound w/ pink paint 15 ND 0 100 D White/tan wall debris 75 ND 30 70 050411-2C EM 734944 A White/peach paint w/ white compound 5 ND 0 100 B White/tan drywall 95 ND 15 85 050411-2D EM 734945 A White/peach paint w/ white compound 5 ND 0 100 B White/tan drywall 95 ND 15 85 050411-2E EM 734946 A White compound w/ gray mastic & cream 15 ND 0 100 paint B White compound w/ cream paint 15 ND 0 100 C White compound w/ brown paint 15 ND 0 100 D White/multi-colored wall debris 55 Chrysotile TR 25 75 Point Count 0.75 N�None Detected TR=Trace, <I"/o Visual Estimate Trem-Ac[=Tremol i [e-Acti nol i [e Note: Further analysis by TEM is recommended for organically bound material (i.e. floor tile) if P�M resul[s are<I"/o. Data QA I �tES 212279 Due Date: g ' � � ' � � � I 1 • • ���''� Ffeservnir� �'nv�ronmenta�, Inc. Page �1_ of Due Time: ' � � T'— , I • IM/OICE TO• (IF DIFFEREN � CONTAC7 INFORMATION: SUBMITTED BY: ��� ��� �a�r HERRON Ente rises USA, lnc. �0f1�'� l.ennie Herron / Office Ph�e: 5: � �� 303-763-9639 �d�8� 7251 W. Hampden Ave. F� � I FBx i Latcewood, CO 80227 , cewa�r. � c�ua�se`: IFinal Data Da9varaDle EmeAAddress: Proiect Number end/or P.O. i: i J Herron Grou Ptolecl DesafpttorVl.xeqon: � � - _ �.. REQUE$TED?,ANACXSES;;. . , , <VALi � �r D+MA'6RIX" Hu1kE B' , �B�NOTE$:;: ,' PRlORITY (Next QaY) _ ,PiSBE$� S=LABQ�ATORY.HOURS:..Weektla s:! 7arn - 7 m , � PLM M/ TEM _ RUSH (Sarne Da� _ ST A I�AFtD � o� .✓' ,. � C ' Dust - D Pa�nt P (Rush RCIN = 2hr, TE11A = 6hr.) CSV RLE R E Q U I R E D � [. C ; o �Q ° � _::: o v� O i Soi{ = S Wipe = W :�li�M�S'GRYLABORATOR?f`HQURS ;Weekda s `�8am!�5pm� : . � + a � � i Drin�ingWater=DW ' Metal(s) ! Dust , RUSH ^ 24 hr 3 5 Day �, � o Wasta Water = W W a° °� ••Prior notiftcaYton is � � � r °° Other = O RCltA 8/ dletals & Welding RUSH ,_ 5 day,_10 day required tor RUSH � � o � � � j Fume SCan ! TCLP — tamarounds'" g, `� �n p A � � � "ASTM E1792 approvad wipe media only'" � m �S� m � � � � 24 hr. 3 day _,6 Day � � 5 ° � �� � Organics — — � Jd � a � E •�.Turnamund Umas aslshlish a �aboratory prioriry, aubjaet to.kboralory vo�ume and aro notguarentaed.. a m AddlttonalYees agplyforallefioun, weakends antl holldays." � W � � � � �,�j ' ? � � c � � W � r°- �� c��t � m v•W D2te iime Spectal tnstructions• ' � '�a � � �. � .� o Collected Cdlected EM .Number • g E g m � oC ��,s_ R:, m U m,�ydyyy hNmm efP (La6oralory;Use Onty} . . . . ., ... . . ..-. 0. � N 0. O � � O O fA � �2 �k Glientsam le,` :, umber (sa�e'i��s:mustneunt�ue) .• :� � � '7 � 1 � � —2 � � _ , i3 : , :_ ; L I � ,2i _ , , � � _ cl.S ..: 3 . ; : � _.. ., u � , _ ... , a, . : _ j ; 5 _ : . .; , , . . . _ , , :s:6•: , _ _ . .. I ,.. 7 , , .8';: � . . ... � 9 , -�;c :,: � � 13 � � Number of sart�ples received: (Addltiional samples shall be listed on aUached long foRn.) � ��,ubmbslon ot lhe I- . N07E: REI will anetY� ��B lea baaed upoh fnfmnel' ked end w�ll not be reaPomible for servfces egreemenl wi�h paymar�t �NET 30 da�ys, f�afGxe W compl�y with peymeN lerms may reaullym a 1.5� %�monlh Y hderest surchar0e. rolbwfnB aempbs tar re9ueated ene as 3ndketed lfria n Cuslody aheq careUh�le an ermlY�ic� . IDateliime: � Sample Condition: On lce Sealed I� Retin uished B: � �so Temp.(�) Y�r� Y/N Y Laboratory Use Only � �L� ' d��.��: � ' �! • t f � � camer: �-�- ` Received 8y. Tj� Ini' Ccntact Page Phone Emaii Fax Date Ttme Initiais Results: Cp�t� ' � j(�j Page hon Email Fex Date ••) I � , COntaCt Pag Email Fax Date • � Tfine InlUsls � ontact Page Phone Emai! Fax Date Tme Initiais 7"� �. 1 , ' , � ' . .,' . � � . ' �.-,.� � -•?� 1 r;.: ' � _ � � ,l T T �i�,%y '� � .� ��. . -.,,�{ y ' �, �p 'rl�,��., �, ��x '1`lY ,t _ ,v ,;c ��,{�? �.��. ,�a.u. .�,�' pF' �*� e,, ��^✓*yzh��, .L�, 1 r'� � . �r xe�lf,. Z,T._ _ N�.`�.K�e �`';�nTc.�7i:�t>.'j'r:iikS�*f�.nq�'.cti.SVS?...... -;`i'*14;fj,'J•'''�`A'�vYO,�.` n`x ���'i�i.��. it�.��'�:,'+�`..�:'_+`'hh'�,�i3titS�2htiS'f+13'.�'.A.G4x�i���.c.l.���:,�.�w}X.;h,!."'��i':�'�Mv'Y�"s`,�'•i+�._.."�t�7d��r'�tt-�:k'R�'v,.+�,.�i.'1.'=�/.���'.i `.n�,9��2+'�1'��.c.. �' '�ti `p y` . .. :�'{ � s7 r'kn�. �r �; '. y��f a >F-r 4 n / .+.{'���"` 4 �k`°� z �' _ � +"'Y'�r.r. � � Q a e p � o A i � � �= ,S�$+ �°�l� , R Y � Q c- .-�� �. �y..�`C- � ?' n` y 11>'_ �� *a `- �} _ 1 e, �,� � j� f Q -�}t�,'�s'F� 4at ��� 0 � 0 0 �',qtnvr 1{ . at,'iY ��4t�' c �#? ;7l1 k'� � Dr;• �,. c� ,d �,��„� �. �,- - �i; d V - 3��qc� � ',. a�, ,�� ; -� d1 'i. " i ,� ° .06 " ' � A 0 p j �+�i: -.�.� •��1 � _ 1 �xd� 1 �' �: ns,�o a °-+ a � : °' : .4e -e :a -c s r- • � o- � A a . �.� � � �� � ��✓� ` ' t I ' m R " • � ' ' � • Il s• , - �°, i ! S s 0 Q r�����y,. x �"� Z ��t : 4,�� . � tir: � y , , y, o �, ,�j.��' � � . �.,, .ra f .-. �� � �. ? I ���� 3�"'34 � ��, �` n � �� N g III � < � � I �.'vK ����4: �. � 6i. �� ' � e • R � � � I �fi �� �,�� : �; ,�, s�, � se�l'�'�F �: ; Q � ��._ �_ rti_� r.� r- -r�. Y • � . t - � a���� i T�� ��.�' ; �. y� 1'� Y � �' y'� f t�ry,� 'v .< "��. e .� -.- � r. . ry�- � y bi �. y1�FS'"� Q�.: ��T,3'"`r'�' � y �' �Y� �' �� �%�aQbS. a ��f S � .;r. � rF dv; Fj'� ` �.`' i . � � 3 � ,! i � �a 2 ,3 , � ,� � � s i , :64+. 6 � Er: . a :, tb. , . : ,. ,. . . . ,.. .� . ,.. . . . . . � . : . . � ,. F..«i . , .x A - . .o. . t .............. .................... .......,...................,..........`.°:...i:.......... _ - �_. .w� .r; �,tim. ' T. .,ve�naq�,wiiq '.1� BgGYCC�,,,:,��c'am,�r•. j�' ` ''rq7�:'"���ix4,�.� ` _��;� � L.?.r'��+�.'-'��,� ti 1 ,c.X �LL. �r,^ '�+r � ' � � ���'R$�>�''� �k?idW �� �C.1- ' �.+^ �"�'��:�1!�' .�. TS � `iT�.t�' "�'a('�,"Kffiww _J^�Yk� .. �'.�. ' �• '•. � .. �„� }, xc . ��f'� . � '�_-'�'�� ' ,..�, .,4 `W'`k'FS7��s941t9p,�f�� 1` F�!;� <M�K l. .� .yrx""�...a�`,� S�n. ,.r ,-'�'r�' �,#',• Sti�1� 'vtu�w..5�-.,[ �';1,�� .s��,ryS��u.°�'`.�.iyl�jik "���.},Cp`. !,}�,���,� �_ . �t':�%14xl� �t+�} .Li _ �.,S.�Z„1.C'.�� ��Y..� yK' .�'..l'I':�} '.��:� •.k5 � � ���':1�1� -•�L'r�:. �.hSF ��1, 1 K�Ji�: rw:i2�'i' FC�. �i�. '91i4 � .�'. i� ll�� t �', i'��i� 7 A1 '.�'I'/_ .�• ' �� ;�,b.��G �: ��'* � �a�,a �+ !,.�� �t�' � d��r �.�1�t " �" j�`�r'�' "L y:i<��1, °`�a '�' „�",��,'a� • ,�.*lr �, �r,:,'. 'L�a� �J<r: � .. �.,,� Yr F � � t .v •'�� i;."� � G �"•.' � �''+�'�, i ��k�f'•� .•�'r(y, ��," ��` ..;r, 4tt'p�~�� � '~�-�, Y F � { �,�;i• ., ��r�'i j:,� . �.fr- �j4� r w�,����: 4, :.'�..� � .r-� r. ., � �� !7 �tF- jij�„ . , v �` t ,,� (? � _ .: 3��'I f� �� . Ex��Kf�,�l '0 r��� yn}.� � . _.. � �w ..� � �r�': �. �:, � Q���,`T{��TI' � : �y �y.. � i . ,;f ' t . ir ; �C° �' ��' ���� � F_ i, � ..,.:,.,� r ���r. .,+�-.+��G+�..y�� .rr.�..:+',?'+' ..:��'�=%';•; ��".;y .,��.. -.p. „<,� H. `�^:ti A�-�,.X: r�.��i'?; f�..,,..ti"`, .'iS.�44t, s�:uM�a^.,� ,-Y 7`�w;s4�' �x'r�ez�`,� ., ..'t:_A?'�,, .�i. ,t�•y1 r ;'e �'�,,i��'� . .ur��# ,�4�g•� �. -?"�M1�QVr��A�. ;An'<��5.� �V '1�: � ;�l'..: ) ,�t,..�,{Y,� s ._. ��- ..x z � � i ; -r p '�� Tav�'r^ +- . � �. ' � � � �} . . `�`_' � �,. j .� ��;."*`.x.. , ' ,� � _;� k ,_ ,�=' �rr� � 1 t :� ,� � . r y i ' � .. . ; . ,_ _ . _ � — � �� ■�■ ��1�r GOBBELL HAYS PARTNERS, INC. 10500 East 54th Avenue, Suite J� Deaver, CO 80239 Ph. (303) 574-0082 � Fax (303) 574-0061 CERTIFIES THAT BILLIE LUSK Has successfully completed The EPA-APPROVED AHERA A5BESTOS COURSE for 4-Hour Buiiding Inspector and 4-Hour Management Planner Refresher. This course is EPA-approved under Section 206 of the Toxic Substances Controi Act (TSCA) and meets the requirements of Colorado Regulation No. 8. Gobbell Hays Partners, Inc. purchased MCA Environmental, Inc. and course approval can be found in the EPA director under MCA Environmental, Inc. listed as training pro�ider #931. �,. f Caurse Date: Exam Date: Certificate No: Expiration Date: 6/7/10 N/A 6/l OBIR/MPRGHPS 6/7/11 I � ���� � Peier D Cappel� STATE 4F COLORAD4 .A�B��TOS . _ ' �E��IFICATION* � � � , : Colorado Department of Public Health i and Envixanrnent i Air Polluti+on Control Divis�t�n � ; { � This certifies that Billie J. Herron-Lusk ' Certification No: 2650 has met the requirements of 25-7'-507, C.RS. and `Air Quality Control Commission Regulation No: 8, Part B, and is hereby certified by the sfate of:Colorado in the following`discipline: " Inspector/Managernent Planner� � � � j Issued: 10/29/2010 > � _�: ' Expires on: 10/29/2011 �� i.,.� ,. � � � � i/ �-" a 1",����.-;.� ; � -- ,'�t! , � ;'" � � f: APCD Representative * This certificate rs valiri o�+ly ►vith tlie possessiur� of a current Divisiaie-appr�ved traire:ng course certifica�ion in the discipline specified above. GOBBELL HAYS PARTNERS, INC. 10500 East 54th Avenue, Suite J� Denver, CO 80239 Ph. (303) 574-0082 �► Fax (303) 574-0061 CERTIFIES THAT DILLON CARSON Has successfully completed The 4-Hour EPA-APPROVED AIiERA ASBESTOS COUR�E for Building Inspector Refresher. This course is EPA-approved under Section 206 of the Toxic Substances Control Act (TSCA) and meets ihe requirements of Colorado Regulation No. 8. Gobbell Hays Partners, Inc_ purchased MCA Environmental, Inc. and course approvaI can be found in the EPA directory under MCA Environmental, Inc. listed as training provider #931. � . ,� � t` �, ''� _ � � �� � Course Date: Exam Date: Certificate No.: Expiration Date: 11/]./10 N/A 11/l OBIRGHP3 11/1/I l i�� � Wade E. Anderson - Director STATE OF C4L4RADC) ASBESTOS CERTIFICATION* Colorado Deparnnent of Public Health and Environment Air Pollution Control Division This certifies that Dillon Carson- Certification No: 14222 has met the requirements of 25-7-507, C.R.S. and Air Qualiry Control Commission Regulation No. 8, Fart B, and is hereby certified by the state of Colorado in the followir�g discipline: < ' Building Inspector* Issued: 11/3/2014 Expires an: 11/3/2011 � � ` - A rized APCD ''--�-------...._.._._., * This certificate is valid only with the possession of a current Division-appro ved trttining course certificatian in the disciPline specified above. 11-30-2011 . . ., ., _ __ Inspection Request Reportin Vail Cn _ Citv nf � � Requested Inspect Date: Thursday December 01, 2011 Site Address: 174 E GORE CREEK DR VAIL LODGE AT VAIL UNIT 522 & 523 A/P/D Information Activity: 611-0159 Type: COMBO Sub Type: AMF Const Type: Occupancy: Use: Owner: SYBIL ROBSON ORR TRUST Contractor: SRE BUILDERS, INC. Phone: (970) 845-6359 Page 6 Status: ISSUED Insp Area: Description: COMBINE UNITS 522 & 523 TOGETHER VIA UPPER FLOOR. RELOCATION OF KITCHEN & POWDER ROOM ON LOWER LEVEL. DELETE ONE BATHROOM AND RELOCATE A BATH ON 2ND FLOOR. RECONFIGURE THE TWO MASTER BATHS ON 2ND LEVEL. RELOCATE STAIRS. ADD ERV + 3 AIR CONDITIONING UNITS. ADD 1 GAS FIREPLACE. CHANGE HEAT TO RADIANT FROM BASEBOARD. Requested Inspection(s) -����`�� �--- tem: 90 B �nal � Reques Comme . 37 - Assi o: JMONDRAGON � Action: Time�x�: °� �, Item: 190 ELEC-Final Requestor: Comments: 376-1536 Assigned To: D ON Action: Item: 290 PLMB-Final Requestor: Comments: 376-1536 Assigned To: JMO GON Action: Item: 390 MECH-Final Requestor: Comments: 376-1536 Assigned To: JMO ON Action: /' , �'��/�/ /� � r �- F � Time Exp: Time Exp: Time Exp: Requested Time: 01:00 PM Phone: Entered By: MHAEBERLE K Requested Time: 10:30 AM Phone: Entered By: MHAEBERLE K Requested Time: 11:00 AM Phone: Entered By: MHAEBERLE K Requested Time: 11:30 AM Phone: Entered By: MHAEBERLE K Inspection History Item: 120 ELEC-Rough "" Approved "" 08/30/1'f Inspector: sgremmer Action: AP APPROVED Comment: Item: 200 MECH-Rough "" Approved "' 07/19/11 Inspector: sgremmer Action: PI PARTIAL INSPECTION Comment: in floor heat in lid above corridor 08/24/11 Inspector: sgremmer Action: AP APPROVED Comment: 08/30/11 Inspector: sgremmer Action: NR NOT READY FOR INSPECTION Comment: 08/31/11 Inspector: sgremmEr Action: AP APPROVED _. _ _ -_ __--. -- — REPT131 Run Id: 13807 0 12-02-2011 .,,, _.v Inspection Request v��i r_n _ r_�r Requested Inspect Date Site Address A/P/D Information Activity: 611-0159 Type: COMBO Const Type: Occupancy: Owner: SYBIL ROBSON ORR TRUST orting ���'�225 Page 1 Monday, December 05, 2011 174 E GORE CREEK DR VAIL LODGE AT VAIL UNIT 522 & 523 Sub Type: AMF Status: ISSUED Use: Insp Area: Contractor: SRE BUILDERS, INC. Phone: (970) 845-6359 Description: COMBINE UNITS 522 & 523 TOGETHER VIA UPPER FLOOR. RELOCATION OF KITCHEN & POWDER ROOM ON LOWER LEVEL. DELETE ONE BATHROOM AND RELOCATE A BATH ON 2ND FLOOR. RECONFIGURE THE TWO MASTER BATHS ON 2ND LEVEL. RELOCATE STAIRS. ADD ERV + 3 AIR CONDITIONING UNITS. ADD 1 GAS FIREPLACE. CHANGE HEAT TO RADIANT FROM BASEBOARD. Requested Inspection(s) Item: 90 BLDG-Final Requestor: Comments: 376-15 Assigned To: J GON Action: �Item: 190 ELEGFinal Requestor: i Comments: 376-1536 Assigned To: JMO ON Action: Item: 290 PLMB-Final Requestor: Comments: 376-1536 Assigned To: JMO ON Action: Item: 390 MECH-Final Requestor: Comments: 376-1536 Assigned To: JMON Action: /� h �� �G ✓ � Time Exp: Time Exp: Time Exp: Time Exp: Inspection Historv Item: 120 ELEC-Rough "' Approved "` 08/30/1'f Inspector: sgremmer Comment: Item: 200 MECH-Rough "" Approved "' 07/19/11 Insp ector: sgremmer Comment: in floor heat in lid above corridor 08/24/11 Inspector: sgremmer Comment: 08/30/11 Inspector: sgremmer Comment: 08/31/11 Inspector: sgremmer Requested Time: 09:30 AM Phone: Entered By: MHAEBERLE K Requested Time: 08:00 AM Phone: Entered By: MHAEBERLE K Requested Time: 08:30 AM Phone: Entered By: MHAEBERLE K Requested Time: 09:00 AM Phone: Entered By: MHAEBERLE K Action: AP APPROVED Action: PI PARTIAL INSPECTION Action: AP APPROVED Action: NR NOT READY FOR INSPECTION Action: AP APPROVED REPT131 Run Id: 13812