Loading...
HomeMy WebLinkAboutPEC110031 Lodge at Vail Minor Alteration Attach C OWNER ROCK RESORTS 390 INTERLOCKEN CRESCENT SUITE 100 BROOMFIELD, CO 80021 VOICE: 303.404.6452 FAX: 303.404.6415 ARCHITECT OZ ARCHITECTURE 3003 LARIMER STREET DENVER, CO, 80205 VOICE: 303.861.5704 FAX: 303.861.9230 KITCHEN DESIGNER COMMERCIAL KITCHEN PLANNERS, INC. P.O. BOX 772934 CORAL SPRINGS, FL, 33077 VOICE: 954.600.0234 FAX: 954.775.2884 STRUCTURAL JIM THOMPSON/KYSE STRUCTURAL 1888 SHERMAN STREET SUITE 770 DENVER, CO 80203 VOICE: 720.932.3744 MECHANICAL ELECTRICAL FIRE PROTECTION BCER ENGINEERS 5420 WARD ROAD SUITE 200 ARVADA, CO 80002 VOICE: 303.422.7400 FAX: 303.422.7900 LIGHTING ELEMENT LIGHTING DESIGN, LLC BOULDER, CO VOICE: 720.560.4931 FAX: 303.443.4031 LANDSCAPE CIVIL DENNIS ANDERSON P.O. BOX 1387 EDWARDS, CO 8632 VOICE: 970.926.7200 FAX: 970.9267201 BCER ENGINEERS 5420 WARD ROAD SUITE 200 ARVADA, CO 80002 VOICE: 303.422.7400 FAX: 303.422.7900 ALPINE ENGINEERING INC 34520 HIGHWAY 6 EDWARDS, CO 81632 VOICE: 970.926.3373 FAX: 970.926.3390 BCER ENGINEERS 5420 WARD ROAD SUITE 200 ARVADA, CO 80002 VOICE: 303.422.7400 FAX: 303.422.7900 OCCUPANCY: A-2 CONSTRUCTION TYPE: V-A SPRINKLERED ALLOWABLE SQUARE FOOTAGE: -ALLOWABLE SQUARE FOOTAGE: -ALLOWABLE SQUARE FOOTAGE: -ALLOWABLE BUILDING HEIGHT: -ALLOWABLE BUILDING HEIGHT: -ALLOWABLE BUILDING HEIGHT: -BUILDING CONSTRUCTION EXTERIOR BEARING WALLS 1 HR INTERIOR BEARING WALLS 1 HR EXTERIOR NON-BEAR'G WALLS 1 HR STRUCTURAL FRAME N.R. 1 HR PARTITIONS (PERMANENT) N.R. SHAFT ENCLOSURES N.R. FLOORS-CEILINGS/ROOFS 1 HR ROOFS-CEILINGS/ROOFS 1 HR STAIRWAY CONSTRUCTION 2 HR EXTERIOR DOORS & WINDOWS N.R. (NOT PERMITTED < 5', PROTECTED < 10') SUPPRESSION SYSTEM = FIRE SPRINKLERED PLUMBING FIXTURE COUNT: RE: PLUMBING DRAWINGS BUILDING CODES 2009 INTERNATIONAL BUILDING CODE (IBC) 2009 INTERNATIONAL MECHANICAL CODE 2009 INTERNATIONAL FUEL AND GAS CODE 2009 INTERNATIONAL PLUMBING CODE 2009 INTERNATIONAL FIRE CODE 2008 NATIONAL ELECTRICAL CODE 2009 INTERNATIONAL ENERGY CONSERVATION CODE PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 174 East Gore Creek Drive Vail, CO 81657 5/10/2011 1:09:33 PM C:\Revit Local Files\511040_Lodge at Vail -Elways Restaurant\511040_Lodge at Vail -Elw ays Restaurant_A11_dvertuc a.rvt 1 : 1 WILDFLOWER RENOVATION THE LODGE AT VAIL 511040.00 Author Checker May12, 2011 DRB AWNING REVIEW COVER DRBT.1 WILDFLOWER RENOVATION THE LODGE AT VAIL Approver ABBREVIATIONS BUILDING AND CODE INFORMATION GRAPHIC STANDARDS PROJECT TEAM VICINITY MAP DRAWING INDEX PROJECT NORTH PROPOSED PERSPECTIVE VIEW VAR VARY or VARIES VB VAPOR BARRIER VCT VINYL COMPOSITION TILE VENT VENTILATION VER VERIFY VERT VERTICAL VEST VESTIBULE VIF VERIFY IN FIELD VIN VINYL or SHEET VINYL VOL VOLUME VTR VENT THROUGH ROOF VWC VINYL WALL COVERING W WEST or WIDE W.O. WHERE OCCURS W/WITH W/C WATER CLOSET W/O WITHOUT W/R WATER RESISTANT WC WALL COVERING WD WOOD WDO WINDOW WF. WIDE FLANGE or WOOD FLOORING WGL WIRE GLASS WP WATERPROOF(ING) WPT WORKING POINT WSCT WAINSCOT WT WEIGHT WWF WELDED WIRE FABRIC YD YARD SUSP SUSPEND(ED) SYM SYMMETRICAL SYS SYSTEM T TREAD T&B TOP AND BOTTOM T&G TONGUE AND GROOVE TB TOWEL BAR TBC TOP OF BACK OF CURB TELE TELEPHONE TEMP TEMPORARY or TEMPERATURE TG TEMPERED GLASS THERM THERMOSTAT THK THICK or THICKNESS THLD THRESHOLD TO TOP OF TOC TOP OF CONCRETE TOS TOP OF STEEL TOW TOP OF WALL TPD TOILET PAPER DISPENSER TPTN TOILET PARTITION TS TUBE STEEL TV TELEVISION TYP TYPICAL UL UNDERWRITER'S LABORATORY UNFIN UNFINISHED UON UNLESS OTHERWISE NOTED UOS UNLESS OTHERWISE SPECIFIED UR. URINAL USGS U.S. GEOLOGICAL SURVEY V VOLT HT HEIGHT HTR HEATER HVAC HEATING, VENTILATION and AIR CONDITIONING HW HOT WATER HWH HOT WATER HEATER HWY HIGHWAY IBC INTERNATIONAL BUILDING CODE or INSTALLED BY CONTRACTOR ID INSIDE DIAMETER IN INCH(ES) INCAND INCANDESCENT INCL INCLUD(ED) INFO INFORMATION INSUL INSULATION or INSULATED INT INTERIOR INTMED INTERMEDIATE INV INVERT JC JANITOR CLOSET JST JOIST JT JOINT KD KNOCKDOWN KIT KITCHEN KO KNOCKOUT KP KICK PLATE LAB LABORATORY LAM LAMINATE LAV LAVATORY LBL LABEL LDR LEADER LH LEFT HAND LKR LOCKER LLH LONG LEG HORIZONTAL LLV LONG LEG VERTICAL LP LIGHTING PANEL or LIGHT PROOF LT LIGHT LTL LINTEL LVR LOUVER MACH MACHINERY MAG MAGNETIC MAS MASONRY MATL MATERIAL MAX MAXIMUM MB MOISTURE BARRIER MECH MECHANICAL MED MEDIUM MEMB MEMBRANE MEP MECHANICAL, ELECTRICAL and PLUMBING MEZZ MEZZANINE MFR MANUFACTURER MH MANHOLE MIN MINIMUM MIRR MIRROR MISC MISCELLANEOUS MM MILLIMETERS MO MASONRY OPENING MTD MOUNT(ED) MTL METAL MUL MULLION (N) NEW N NORTH NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NRC NOISE REDUCTION COEFFICIENT NTS NOT TO SCALE OA OVERALL OC ON CENTER OD OUTSIDE DIAMETER OF OUTSIDE FACE OFF OFFICE OH OPPOSITE HAND OPNG OPENING OPP OPPOSITE OTO OUTSIDE-TO-OUTSIDE P PAINT(ED) P/L PROPERTY LINE PAC PREVIOUSLY AWARDED CONTRACT PAR PARALLEL PBO PROVIDED BY OTHERS PC PRECAST PERF PERFORATED PERIM PERIMETER PKG PARKING PL PLATE PLAM PLASTIC LAMINATE PLAS PLASTER PLBG PLUMBING PLYWD PLYWOOD PNL PANEL POL POLISHED PR PAIR or PROPOSAL REQUEST PREFAB PREFABRICATED PREFIN PREFINISHED PRESTR PRESTRESSED PRIM PRIMARY PROJ PROJECT PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT POST TENSIONED or PORCELAIN TILE PT POINT OF TANGENCY PTD PAPER TOWEL DISPENSER PTDR PAPER TOWEL DISPENSER AND RECEPTACLE PTN PARTITION PTR PAPER TOWEL RECEPTACLE PVC POLYVINYL CHLORIDE PVMT PAVEMENT QT QUARRY TILE QTY QUANTITY (R) REMOVE R RISER RAD RADIUS RB RUBBER BASE RBC RUBBER BASE COVE RBS RUBBER BASE STRAIGHT RBT RUBBER TILE RD ROOF DRAIN or ROAD RE REFER TO or REFERENCE REC RECESS(ED) RECPT RECEPTACLE REF REFRIGERATOR or REFRIGERATED REINF REINFORCED REQD REQUIRED RESIL RESILIENT REV REVISE, REVISED or REVISION(S) RF RESILIENT FLOORING RFG ROOFING RFL REFLECTED RH RIGHT HAND RL RAIN LEADER RM ROOM RO ROUGH OPENING ROD ROOF OVERFLOW DRAIN ROW RIGHT OF WAY RPM REVOLUTIONS PER MINUTE RVS REVERSE (SIDE) RWC RAIN WATER CONDUCTOR S SOUTH or SEALED SC SOLID CORE SCD SEAT COVER DISPENSER SCHED SCHEDULE SD SOAP DISPENSER SEC SECTION SF SQUARE FEET SHT SHEET SHTG SHEATHING SHWR SHOWER SIM SIMILAR SNC SANITARY NAPKIN CABINET SND SANITARY NAPKIN DISPENSER SNR SANITARY NAPKIN RECEPTACLE SOFF SOFFIT SPECS SPECIFICATION(S) SPKL SPRINKLER SPKR SPEAKER SPRT SUPPORT SQ SQUARE SR SINK RECEPTACLE SS STAINLESS STEEL SSK SERVICE SINK STA STATION STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURE or STRUCTURAL # POUND(S) or NUMBER & AND < ANGLE @AT A/V AUDIO/VISUAL AB ANCHOR BOLT ABV ABOVE ACOUS ACCOUSTICAL ACT ACCOUSTICAL CEILING TILE AD AREA DRAIN or ACCESS DOOR ADD ADDENDUM ADJ ADJACENT or ADJUSTABLE AFF ABOVE FINISHED FLOOR AGG AGGREGATE AHU AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM ANOD ANODIZED APPROX APPROXIMATE ARCH ARCHITECTURAL ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTIONS ASPH ASPHALT AUTO AUTOMATIC AVE AVENUE AVG AVERAGE AWP ACOUSTICAL WALL PANEL B BASE B.O. BY OWNER B.O.F. BY OWNER, FUTURE BD BOARD BIT BITUMINOUS BLDG BUILDING BLKG BLOCKING BM BEAM or BENCH MARK BOT BOTTOM BRG BEARNING BSMT BASEMENT C CAULKING C.L. CENTERLINE CAB CABINET CATV CABLE TELEVISION CCD CONSTRUCTION CHANGE DIRECTIVE CCTV CLOSED CIRCUIT TELEVISION CDOT COLORADO DEPARTMENT OF TRANSPORTATION CEM CEMENTITIOUS CFL COUNTERFLASHING CG CORNER GUARD CIP CAST IN PLACE CIRC CIRCUMFERENCE CJ CONTROL JOINT CK CORK TILE CL COLUMN LINE CLG CEILING CLOS CLOSET CLR CLEAR CM CENTIMETERS CMU CONCRETE MASONRY UNIT CO CHANGE ORDER or CLEANOUT COL COLUMN CONC CONCRETE CONF CONFERENCE CONN CONNECTION CONSTR CONSTRUCTION CONT CONTINUOUS CONTR CONTRACTOR CORR CORRIDOR or CORRUGATED CPT CARPET CT CERAMIC TILE CTR COUNTER CU CUBIC CY CUBIC YARD DAMP DAMPROOFING DBL DOUBLE DEG DEGREE DEMO DEMOLISH or DEMOLITION DEPT DEPARTMENT DF DRINKING FOUNTAIN DIA DIAMETER DIAG DIAGONAL DIM DIMENSION DISP DISPENSER DIV DIVISION DN DOWN DR DOOR DS DOWNSPOUT DTL DETAIL DWG DRAWING DWR DRAWER (E) EXISTING E EAST EA EACH EB EXPANSION BOLT ED EXHAUST DUCT EF EXHAUST FAN or EACH FACE EJ EXPANSION JOINT EL ELEVATION ELEC ELECTRICAL ELEV ELEVATOR EMER EMERGENCY ENGR ENGINEER EOS EDGE OF SLAB EQ EQUAL EQUIP EQUIPMENT ES EACH SIDE EST ESTIMATE ESTIMATE EW EACH WAY EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXT EXTERIOR F FARENHEIT FA FIRE ALARM FAC FIRE ALARM CABINET FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHER(S) FD FLOOR DRAIN or FIRE DAMPER FDN FOUNDATION FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FF FINISHED FLOOR FFL FINISHED FLOOR LINE FH FIRE HYDRANT FHC FIRE HOSE CABINET FHMS FLAT HEAD MACHINE SCREW FHV FIRE HOSE VALVE FHWS FLAT HEAD WOOD SCREW FIN FINISH(ED) FIXT FIXTURE FLG FLASHING FLR FLOOR(ING) FLUOR FLUORESCENT FOC FACE OF CONCRETE FOF FACE OF FINISH FOM FACE OF MASONRY FOS FACE OF STUD FR FIRE RESISTIVE or FIRE RATED FRP FIBERGLASS REINFORCED PANEL(ING) FRT FIRE RETARDANT TREATED FT FOOT (FEET) FTG FOOTING FURN FURNISH(ED) FURR FURRED or FURRING FUT FUTURE FVC FIRE VALVE CABINET GA GAUGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GCMU GLAZED CONCRETE MASONRY UNIT(S) GI GALVANIZED IRON GL GLASS or GLAZING GND GROUND GR GRADE GRT GROUT GT GLASS TILE GWB GYPSUM WALLBOARD GYP GYPSUM GYP. BD. GYPSUM BOARD BOARD HAS HEADED ANCHOR STUD HB HOSE BIB HC HOLLOW CORE or HANDICAPPED HDAS HEADED DEFORMED ANCHOR STUD HDR HEADER HDWR HARDWARE HM HOLLOW METAL HORIZ HORIZONTAL HR HOUR 01-GENERAL DRBT.1 COVER N/A X 07-LANDSCAPE ARCHITECTURE L.1 LANDSCAPE PLAN 1/8" X 09-ARCHITECTURE DRB2.1 PLANS 1/8" X DRB2.2 ELEVATIONS 1/8" X DRB2.3 DETAILS N/A X SHEET # SHEET DESCRIPTION SCALE 05/12/11 DRB N/A N/A 174 East Gore Creek Drive Vail, CO 81657 DRB AWNING REVIEW May12, 2011 WILDFLOWER RENOVATION THE LODGE AT VAIL DRB2.2 1 2 DRB2.2 EXISTING WILDFLOWER RESTAURANT EXISTING KITCHEN EXISTING MICKEY'S BAR EXISTING OUTDOOR PATIO EAST ENTRY CUCINA RESTAURANT A4.1 2 A4.1 1 106 LOUNGE 106 KITCHEN 107 GREASE 108 DISHWASHING 109 CASUAL DINING 111 ATRIUM DINING 112 BAR SEATING 113 BAR 114 OUTDOOR SEATING 115 DRB2.2 5 6 DRB2.2 3 4 EXISTING NEW 4" /12" 4" /12" 4" /12" 4 1/2" /12" 3" /12" 4" /12" 4" /12" 1" /12" 1" /12" 1" /12" 1" /12" 3" /12" EXISTING COLORED CONCRETE TO REMAIN EXTERIOR MATERIALS PLAN KEY NEW COLORED CONCRETE OVER EXISTING SNOWMELTED CONCRETE SLAB NEW SNOWMELTED COLOR CONCRETE PATIO -COLOR TO MATCH EXISTING PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 174 East Gore Creek Drive Vail, CO 81657 5/10/2011 1:08:21 PM C:\Revit Local Files\511040_Lodge at Vail -Elways Restaurant\511040_Lodge at Vail -Elw ays Restaurant_A11_dvertuc a.rvt As indicated WILDFLOWER RENOVATION THE LODGE AT VAIL 511040.00 Author Checker May12, 2011 DRB AWNING REVIEW PLANS DRB2.1 WILDFLOWER RENOVATION THE LODGE AT VAIL Approver 1/8" = 1'-0" 1 LEVEL 1-EXISTING PLAN 1/8" = 1'-0" 2 LEVEL 1-PROPOSED PLAN 1/8" = 1'-0" 3 EXISTING ROOF PLAN 1/8" = 1'-0" 4 PROPOSED ROOF PLAN EXISTING WOOD SHAKE ROOF EXISTING WOOD SHAKE ROOF NEW BLACK CANVAS AWNING 69 SF OF LANDSCAPE TO BE REMOVED 85 SF OF LANDSCAPE TO BE REMOVED 42 SF OF LANDSCAPE TO BE REMOVED 175 SF OF LANDSCAPE TO BE ADDED 21 SF OF LANDSCAPE TO BE ADDED NEW COLORED CONCRETE FINISH TO MATCH EXISTING. NEW PORTABLE ALLUMINUM RAILINGS SNOW MELTED NEW CONCRETE PATIO. EXISTING FLAT ROOF EXISTING FLAT ROOF 0' 4' 8' 16' N NEW COLORED SNOWMELTED CONCRETE SLAB TO MATCH EXISTING. CAP EXISTING DRAIN. LEVEL GRADE UNDER AWNING. NEW DRAIN INLET TO TIE INTO EXISTING PIPES. EXISTING RETAINING WALL 1/8" = 1'-0" 5 PROPOSED RCP L2 TRACK TO BE MOUNTED TO CEILING STRUCTURE L1 STRINGER LIGHTS TO HANG FROM CEILING SUSPENSION POINTS NOTE: PATIO ROOF PROVIDES FULL CUT-OFF FOR FIXTURES SPECIFIED. NOTE: TOTAL LANDSCAPE ADDED IS 196 SF NOTE: TOTAL LANDSCAPE REMOVED IS 196 SF Level 1 100' -0" Level 2 112' -0" BEAM TEMP2 107' -11" Level 1 100' -Level 2 112' -Level 1 100' -0" Level 2 112' -0" BEAM TEMP2 107' -11" Level 1 100' -0" Level 2 112' -0" Level 1 100' -0" Level 2 112' -0" BEAM TEMP2 107' -11" Level 1 100' -0" Level 2 112' -0" Level 1 100' -0" Level 2 112' -0" BEAM TEMP2 107' -11" Level 1 100' -0" Level 2 112' -0" Level 1 100' -0" Level 2 112' -0" BEAM TEMP2 107' -11" Level 1 100' -0" Level 2 112' -0" Level 1 100' -0" Level 2 112' -0" BEAM TEMP2 107' -11" Level 1 100' -0" Level 2 112' -0" EXISTING WOOD SHAKE SHINGLE ROOF EXTERIOR MATERIAL LEGEND NEW TEMPORARY ROOF/AWNING EXISTING STUCCO FINISH EXISTING WINDOW TO REMAIN NEW INSULATED WOOD FRAMED WINDOW: PAINT TO MATCH EXISTING PROJ. NO. DRAWN: CHECKED: DATE: REVISIONS © OZ ARCHITECTURE SCALE: SHEET NUMBER SHEET TITLE: ISSUED FOR: APPROVED: 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 174 East Gore Creek Drive Vail, CO 81657 5/10/2011 1:09:13 PM C:\Revit Local Files\511040_Lodge at Vail -Elways Restaurant\511040_Lodge at Vail -Elw ays Restaurant_A11_dvertuc a.rvt As indicated WILDFLOWER RENOVATION THE LODGE AT VAIL 511040.00 Author Checker May12, 2011 DRB AWNING REVIEW ELEVATIONS DRB2.2 WILDFLOWER RENOVATION THE LODGE AT VAIL Approver 1/8" = 1'-0" 1 EXISTING SOUTH ELEVATION 1/8" = 1'-0" 5 PROPOSED SOUTH ELEVATION 1A 1/8" = 1'-0" 2 EXISTING EAST ELEVATION 1/8" = 1'-0" 6 PROPOSED EAST ELEVATION 2A 0' 4' 8' 16' 7 8 PROPOSED PERSPECTIVE EXISTING PERSPECTIVE EXISTING WOOD SHAKE ROOF NEW BLACK CANVAS AWNING POWDER COATED GRAPHITE ALUMINUM RAILING POWDER COATED BLACK TUBESTEEL COLUMNS NEW BLACK CANVAS AWNING POWDER COATED GRAPHITE ALUMINUM RAILING TAN CANVAS ROLL DOWN PANELS EXISTING COLORED CONCRETE PATIO TO REMAIN TAN CANVAS ROLL DOWN PANELS EXISTING DOOR TO BE RELOCATED EXISTING BAY WINDOW TO BE REMOVED NEW WINDOW TO MATCH EXISTING TO BE ADDED NEW DOOR TO BE ADDED TO EXTERIOR WALL. NOT SEEN IN ELEVATION. BEHIND CANVAS PANELS EXISTING STUCCO EXISTING STUCCO EXISTING WOOD SHAKE ROOF 1/8" = 1'-0" 3 PROPOSED SOUTH ELEVATION 1 1/8" = 1'-0" 4 PROPOSED SOUTH ELEVATION 2 9 PROPOSED PERSPECTIVE 1A WINTER CONDITIONS: CANVAS SCREENS DOWN SPRING, SUMMER & FALL: CANVAS SCREENS RETRACTED WINTER CONDITIONS: CANVAS SCREENS DOWN SPRING, SUMMER & FALL: CANVAS SCREENS RETRACTED WINTER CONDITIONS: CANVAS SCREENS DOWN SPRING, SUMMER & FALL: CANVAS SCREENS RETRACTED 3003 Larimer Street Denver, Colorado 80205 phone 303.861.5704 174 East Gore Creek Drive Vail, CO 81657 WILDFLOWER RENOVATION THE LODGE AT VAIL 511040.00 Author Checker May12, 2011 DRB AWNING REVIEW DETAILS DRB2.3 WILDFLOWER RENOVATION THE LODGE AT VAIL Approver EverDur™ Ornamental Aluminum Fencing Pickets: ¾ inch square, 0.062 inch wall, typ. Rails: 11/8 inch x 1¼ inch U-Channel, 0.100 inch wall sides & top, typ. Posts: 2½ inch square, 0.125 inch wall, with fl at caps, typ. Gate Posts: 3 inch square, 0.125 inch wall, with ball fi nials, typ. Rail Joint: External Bracket, typ. Picket Attachment: Industrial drive rivets, typ. Aluminum Alloy: 6063-T6, typ. Coating: Powder Coating, AAMA compliant 2604-05, typ. Footings: Concrete, ½” aggregate, typ. * All EverDur™ ornamental fencing is manufactured and installed exclusively by Perfection Fence Corp. Fabric: Specify type and/or brand. CANVAS -Woven acryl ic fabric is U.V. and mi ldew resistant and water repellent. Available in solid colors and striped patterns. Some solids and patterns available in a fl ame resistant series. VINYL -Laminated or coated polyester fabric is U.V. and mildew resistant and water repellent. Available in solid colors and with protective coatings. Also available in translucent colors for backlighting. Most vinyl fabrics are fl ame resistant, consult factory. Frame: STEEL -Galvanized square and rectangular ASTM A-500 steel tube with smooth, clear polymer fi nish. Connections are welded and coated with rust inhibitive paint to match galvanized fi nish. Fabric attaches to frame either by lacing, tec screws or C-molding. Mounting: Awning and canopy frames are furnished with wall brackets for mounting to masonry, wood and E.I.F.S. Canopies are furnished with galvanized square steel tube posts. Specify post fl ange or sleeve and footer. HEATHER BEIGE CANAS REMOVABLE SIDES CHARCOAL TWEED CANVAS ROOF BLACK HAMMER POWDER COAT FINISH FOR METAL FRAME EXISTING PERSPECTIVE OF WILDFLOWER EXISTING PERSPECTIVE OF WILDFLOWER PROPOSED PERSPECTIVE OF WILDFLOWER RENOVATION CONCEPT OF PROPOSED AWNING DESIGN BLACK HAMMER POWDER COAT FINISH FOR METAL FENCE CONCEPT FENCING IMAGE FENCE DETAILS AWNING SPECIFICATION ORNAMENTAL FENCE SPECIFICATION