HomeMy WebLinkAboutB11-0143 PlansNEW WALL PER PLAN OR EXISTING WALL TO REMAIN AT A SIM. SAW -CUT EXIST. SLAB 8" MIN EXISTING SLAB TO REMAIN 1- 4" 1 4 #5 BARS @ 8" o.c. BOTH WAYS DRILLED 6" INTO EXISTING SLAB AND GROUTED w / NON - SHRINK EPDXY 99' -4 "99'-4"1-6 9Y4, 8„ DF #2 GLUE[ NAILEE RAIL COLUMN SECTION 1/2" DIA. ANCHOR BOLTS EACH SIDE OF EACH RAIL COLUMNS INTO NEV FNDN. d 4 "MAX. TREATED 2x6 or 2x4 PLATE w/ 1/2" DIA. ANCHOR BOLTS @ 36" o.c. Town of Vail AND ADJOINING RAIL COLUMNS REVIEWED FOR CODE COMPLIANCE Date: 7 —/ — t — c By: r EXISTING SLAB ;ode Of TO BE REMOVED PER PLAN 3 Y 2 „ v = III —_' • z_ 00 "v I_ —II I o 0 II I I_ o o II o 0 TOW 100' -0" � r 0 TOP OF SLAB A, 99-4" 5 ' -3 y 4 , ( S � A 1 mm } 0 8" } I !. 3 - LVL 1 3/4 x 91/2 GLUED A DETAIL A F AND NAILED TOP OF SLAB 100' - 0" 4 -16d SPIKE TOE -NAIL EACH SIDE ALL RAIL COLUMNS TOP AND BOTTOM A35 FRAMING ANCHOR BOTH SIDES TOP AND BOTTOM ALL RAIL COLUMNS 4 "MAX RAIL COLUMN ELEVATION 1 1/2" = V -0" S 1 1/2" = V -0" v MN T `_ 4— GO E_ /- L — J A S1 EXISTING PAD /PIER TO REMAIN - SIM. DOWEL HORIZONTAL REINFORCEMENT TO EXISTING PIER - DRILL 6" INTO PIER AND GROUT w/ NON - SHRINK EPDXY WALL LEGEND CONCRETE WALLS TO BE ADDED EXISTING WALLS TO REMAIN FOUNDATION PLAN NOTE- ELEVATOR CAR IS 40 "x54" DESTINY AS MANUFACTURED BY THYSSENKRUPP. SEE DESIGN GUIDE FOR ALL DETAILS AND SPECIFICATIONS FOR TYPE 1 RIGHT HAND ELEVATOR AND COMPACT MACHINE ROOM. EXISTING TOW 99' -8" Al Town of Vail F 9 L � ICr C opy EXISTING FOUNDATION TO REMAIN PROVIDE BONDING AGENT BETWEEN EXISTING CONCRETE AND NEW CONCRETE TYPICAL EXISTING WOOD WALL ABOVE EX. v TOF 96-0" 50 �s s �i • CONNECT NEW FNDN. TO EXISTING FNDN. w/ 4 - #5 DOWELS x 3I 0" DRILLED 6" INTO EXISTING FNDN. AND GROUTED w✓ NON - SHRINK EPDXY. ( 2 LOCATIONS TYP.) 0 -1 j 1/4" = 1' - 0 " NORTH A r, O N Q N U �m C c � � m O v a� E v o ox N � O 0 c i Q 0 z H O 0 0 a W 0 ? O Cc Z Q 0 = W D W womo � J Q 00 (� (D U > Q ItO m Q f— N o Q S1 of 11/2 9y2„ 1 y2„ 9 STRUCTURAL SPECIFICATIONS I ) Foundation design based upon assumed maximum soils bearing capacity of 2000 psf to be verified by a soils engineer at the time of excavation. All footings are to bear upon natural undisturbed soil or compacted structural fill as approved by the soils engineer. Soils engineer to inspect basement areas for radon gas. Install ra- don gas system beneath concrete slabs when required by the soils engineer. Sub- mit copy of report to engineer. 2) All foundation around perimeter of structure shall have minimum frost protection of48" to bottom of footing. All foundation walls and columns to be centered on concrete footings unless sho%%v otherwise on plans. 3) All cast in place concrete must be made with Portland cement and attain mini- mum compressive strength of 3000 psi after 28 days (nunimum compressive strength of 4000 psi after 28 days for concrete used in slabs). Design based upon BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318). 1999. Concrete placement to conform with "Construction Requirements" as defined in ACI 318. All concrete slabs on grade must be provided control (scored or cut) in accordance Nvith soils report. All exposed edges of concrete shall have Y'• clanrfer. Concrete work shall not have any horizontal cold joints unless au- thorized be the engineer. Field coordinate all vertical cold joints with structural engineer. use continuous vertical water stop at all cold joints. 4) Reinforcing steel is ASTM Grade 40. All welded wire fabric must conform to ASTM AI85. Reinforcement placement shall conform to MANUAL OF STAN- DARD PRACTICE, 2001 as prepared by CRSI. All lap splices to be nunimum 36 bar diameters. all horizontal reinforcement to be continuous around corners and at wall intersections. Minimum reinforcement protection- - concrete poured against earth 3" - concrete poured in forms 2" - concrete slabs 1'" S) All lumber shall be Doug -Fir #2 S4S or better, all wolmanized lumber shall be Hem -Fir #2 S4S or better (all lumber within 18" of finish grade or in contact with concrete trust be wohnanized). Provide solid blocking at 8' -0° on center in all diaphragms. All columns to be continuous bearing to foundation 6) Anchor bolts and bolls shall be A307 or better. 7) Sheath all interior elevator walls with' / plywood with minimum span rating of 24 or better. Nail with 8d n_: 6" oc to all studs. 8) Live loads used for design- - Roof -100 psf snow (4:12 roof). -80 psf (8:12 roof). - Floor -40 psf residential. - Deck -100 psf. - Wind -90 mph (3 second gust), Exposure B. - Earthquake -Zone C -IBC. 9) All construction must comph %with the 2009 International Building Code as adopted by the Town of Vail Building Department and the "General Conditions of the Contract for Construction' (AIA Document A201). All construction must be completed within the tolerances described in the "Residential Construction Per- formance Guidelines" as prepared by the NATIONAL ASSOCIATION OF HOME BUILDERS. 10) Construct wall as follows- - Exterior- 2x6 zr: 16' oc. - Interior -2x4 r& 16" oc, unless noted otherwise. 11) All beams. joists. and rafters are to bear upon walls or beams. or be hung with SIMPSON Strong -Tie hangers or approve equals. 12) All structural members are shown in their final positions properly braced and sup- ported: during construction it may be necessary to temporarily shore portions of the structure while other portions are being constructed. Contact the engineer for consultation as required. 13) General Contractor is responsible for all non - specified connections, contact engi- neer for details as required. The engineer is to approve all structural substitutions. 14) General Contractor is to coordinate all diapluagm penetrations (i.e.. chimneys. plumbing. sewers, etc.) through floors. walls. roofs and foundation walls %% ith ap- propriate sub- contractors. General Contractor is responsible forthe means, meth- ods• techniques. sequences. procedures, workmanship. seasonal scheduling and job -site safety associated with this project. The General Contractor is to %cri y all dimensions and elevations with the architectural drawings. Notify engineer of all conflicts and omissions between various elements of the working drawings and the existing conditions prior to commencing with that portion of the project. General Contractor is to inspect remodel projects and verify prior use and proper disposal of existing materials (i.e.. asbestos. etc.) as required by code. Identity of all existing hidden structural members based upon visual inspection. 15) All materials exposed to exterior and or moisture conditions shall be treated for these conditions (i.e., chemical treatment. staining• painting, darnproofmg, mem- branes. flashing. etc.) as required by code. All materials to be treated or protected for fire resistance as required by code. 16) Special inspection to be completed by building official approved inspection agency for poured -in -place concrete construction including reinforcing steel, and soils information. Inspection reports to be prepared in accordance %with IBC Chapter 17 on approved forms. verifying compliance %with construction documents and be submitted to the building official for review and approval. copying the owner, general contractor and engineer. Coordinate inspections %with general contractor so that special inspections can be periodic rather than continuous. 0 0 Town of Vail REVIEWED FOR CODE COMPLIANCE Date: 7- By: - Cod D / FIELD VERIFY N EXISTING X HANGER WITH Cl) ■ UPLIFT CAPACITY EXISTING JOISTS TO REMAIN M V 8Y4" bl L 5x5x1 /4 w/ 2 - 3/4" L 3y2" 1 LO DIA. M.B. THRU J 15y GL31 /8x 12 AND 4 - 3/4" DIA. M.B. S� THRU 3 -2x12 (2 M _ TOP OF SLAB TYPICAL) tY w 109' -0" 00 w FIELD VERIFY = N o N N ■ ELI �2 EXISTING LL �, 5 7/ 8 „ HANGER WITH UPLIFT CAPACITY ao 00 _ N �EXISTI EAM TO REMAIN co *_ ■ —i■ ' Towr of V FIC ' C 6PY � - \S'! \N 10 RAMP Z 5' -3Y4" 3 � 2 ' 5�2 w 0.' YELLOW CEDA GL 3 1/8 x 12 5' -1 " N X TO oo N N LU H Q L 0 WALL LEGEND EXISTING WALLS TO REMAIN WALLS TO BE ADDED EXISTING JOISTS TO REMAIN ALAS YE LO CE DA GL 3 1/8 x 12 J (/ vJ N EDGE CANTIL E Z I 0 M V Q X I / uI } w 2 � EDGE CANTIL E SECOND LEVEL FRAMING DENOTES 1 12 Pi'�WOOD GLUED AND NAILED 1/4" - 1 -0 TO FRAMING. r O N Q NT N N � m 0 E o N O O O � n v y o o. > ® 0 Z P H p H Q Q 2 0? In 0 Q °Er< ' O rr O W < ED � J Q 00 < �O It J m / Q I— V 0 S2 of 3 INVERTED HANGER OR BOLTED CONN. PER CONN. OTHER END OF BEAM (2 TYPICAL) O N LU EXISTING Z 2x12 RIM TO D REMAIN J °° N LLI a U) w X W iI L LO J SECOND LEVEL FRAMING DENOTES 1 12 Pi'�WOOD GLUED AND NAILED 1/4" - 1 -0 TO FRAMING. r O N Q NT N N � m 0 E o N O O O � n v y o o. > ® 0 Z P H p H Q Q 2 0? In 0 Q °Er< ' O rr O W < ED � J Q 00 < �O It J m / Q I— V 0 S2 of 3 INVERTED HANGER OR BOLTED CONN. PER CONN. OTHER END OF BEAM (2 TYPICAL) O N LU EXISTING Z 2x12 RIM TO D REMAIN J °° N LLI a Town of Vail REV FOR CODE COMPLIANCE Bate: By: ys Code: OPEN EXISTING ROOF BEAN TO REMAIN 5/2' M SEE ARCHITECTURAL PLANS OR COMPACT MACHINIf ROOM SIZE AND LAYOUT BENEATr BENCH O N LLI z D 00 N w Town of Vail OFFICE COPY u SHAFT DIMENSIONS 3/4" = 1' -0" THIRD LEVEL FRAMING V— DENOTES 1/2 TO FRAMING. j� TOP OF PLYWOOD 118' -2 1/2" [::D) z_ Q 0 PER ARCH'LS o Q H co 2 N N co y 6 0 N 2x4 2 2 H- W (h Z C � z r co x N W r 57/8 2' 1, 1. -1178 AND NAILED 1/4" = 1' - 0 " 0 N Q N ' N � � m O a� E 40 0 N O no Z 0 H 0 ° a W 0 > 0 a °°r< W 0�0 W woo � � J Q 00 0 (.6C) > 4 1-o m a N � a F — s3of 3 r EDGE OF CANTILEVER 2x6 LEDGER NAILED TO WALL M SEE ARCHITECTURAL PLANS OR COMPACT MACHINIf ROOM SIZE AND LAYOUT BENEATr BENCH O N LLI z D 00 N w Town of Vail OFFICE COPY u SHAFT DIMENSIONS 3/4" = 1' -0" THIRD LEVEL FRAMING V— DENOTES 1/2 TO FRAMING. j� TOP OF PLYWOOD 118' -2 1/2" [::D) z_ Q 0 PER ARCH'LS o Q H co 2 N N co y 6 0 N 2x4 2 2 H- W (h Z C � z r co x N W r 57/8 2' 1, 1. -1178 AND NAILED 1/4" = 1' - 0 " 0 N Q N ' N � � m O a� E 40 0 N O no Z 0 H 0 ° a W 0 > 0 a °°r< W 0�0 W woo � � J Q 00 0 (.6C) > 4 1-o m a N � a F — s3of 3 Co/ Lil i� rt ......... �, J� !II �'�, P-C-� UA V-4-- NZ7 - - f� Z� - 1 — 1 -- - IGi�-� -►-+tr I-1 ` I i � � i � 1—et; LAA V- r W ci 0 UJI a 0 M 0. k LL > LLJ 0 Lij LLj 1 AY 2 4 2011 TOWN OF VAIL 131140014 'A IN A- _ -� huv w I.I who II Vft 0 Lo W I u rebI' l -I L. L- I IJ t�tb Wlutaokl��lllJca � ' —_J7 Li 1 ( U 1 I W 1 Z\4 !03 I /�1 2�/z -�v cd� LL1 Q CL cz u qm x� 23� v MAY z 4 zon TOWN OF VAIL 4-D otal I t9,w- wow. a 4 4 W orwo d P I - cp.a. 401 40- m cr OLv- 151 co "01Z4.1 1 54-H Avv+. Z1. I t � f �� nn C ode D, ���.Q. M AY 24 2011 �_ AWN OF VAIL 4- 1 ;,� s DF #2 GLUEC NAILEC NEW WALL PER PLAN OR EXISTING WALL TO REMAIN AT A SIM. SAW -CUT EXIST. SLAB —� EXISTING SLAB TO REMAIN 1- 245 BARS CONT. TOP AND BOTTOM � I 99' -0 II OL #4 DOWELS Iii @ 16" o.c. V-5" .I i g _I�1 2 - #5 BARS I I I CONT. \ 3 - LVL 1 3/4 x 9 1/2 GLUED AND NAILED • • • III ,,_III 4" $„ TREATED 2x6 or 2x4 PLATE w/ 1/2" DIA. ANCHOR BOLTS @ 36" o.c. a AND ADJOINING RAIL COLUMNS _ #4 DOWELS @ 16" o.c. 1' -0" o� � O DRILLED 6" INTO EXISTING $ „ GO ci SLAB AND GROUTED w / 4 1/2" Mile NON - SHRINK EPDXY 6" r �A EXISTING SLAB ���V 0 TO BE REMOVED ��_ ��P I� u SLAB PER v `v` u PLAN 9 EXISTING FOUNDATION ?/4 .'8" TO REMAIN 5' -3 y 4 „ $„ I 4" CONCRETE SLAB ON C) GRADE REINFORCED w/ TOW TOF A WWF 6x6/10x10 CENTERED • l i = ' 100' -0" 99 -0 S 1 w/ 1/2" EXP. MAT'L I I I AROUND PERIMETER -I I r ..' h °° - 5 - - 4" , A S1 TOP OF SLAB 99'-4" . TOP OF SLAB 1 ', 4 " _ F � OR RAIN 4 b 8" N /— 1L A D E TA I L A �M G GO P AN S 1 1/2" = 1' -0" �-�O L_ — J RA IL COLUMN SECTION 1/2" DIA. ANCHOR BOLTS EACH SIDE OF EACH C RAILCOLUMNS INTO NEW FNDN. LJ 4 "MAX. P� EXPANDED FOOTING 3'- 6 "x3' -6 "x10" w/ 4 - #5 BARS EACH WAY 4 -16d SPIKE TOE -NAIL EACH SIDE ALL RAIL COLUMNS TOP AND BOTTOM A35 FRAMING ANCHOR BOTH SIDES TOP AND BOTTOM ALL RAIL COLUMNS L� 4 "MAX RAI CO ELEVATION 1 1/2" = 1' -0" WALL LEGEND CONCRETE WALLS TO BE ADDED EXISTING WALLS TO REMAIN J FOUNDATION PLAN NOTE- ELEVATOR CAR IS 40 "x54" DESTINY AS 1/4" = 1' - 0 " MANUFACTURED BY THYSSENKRUPP. SEE DESIGN GUIDE FOR ALL DETAILS AND SPECIFICATIONS FOR TYPE 1 RIGHT HAND ELEVATOR AND COMPACT MACHINE ROOM. A � l S1 SIM. EXISTING TOW 100' -0" EX. v TOF 96' -0" 7� U �m c �N - N � � m o 0 m m E N O a° i 0 Z H O 0 a 0?`- 0 a 0 mm W 0�O W wm0 a �Q 00 0 � o' It J m M Q I- N o Q M 1IE C� r �aWI Q 24 2011 CV V OF VAIL NORTH S 1 of 3 1 1/2 , 9y2„ 1 CONNECT N W FNDN. TO EXISTING FNDN. w/ 4 - #5 DOWELS x 3 -0" DRILLED 6" INTO EXISTING FNDN. AND GROUTED NON - SHRINK EPDXY. (2 OCATIONS TYP.) M 1IE C� r �aWI Q 24 2011 CV V OF VAIL NORTH S 1 of 3 1 1/2 , 9y2„ 1 STRUCTURAL SPECIFICATIONS 1) Foundation design based upon assumed maximum soils bearing capacity of 2000 psf to be verified b) a soils engineer at the time of excavation. All footings are to bear upon natural undisturbed soil or compacted structural fill as approved by the soils engineer. Soils engineer to inspect basement areas for radon gas. Install ra- don gas system beneath concrete slabs when required by the soils engineer. Sub- mit copy of report to engineer. 2) All foundation around perimeter of structure shall have minimum frost protection of 48° to bottom of footing. All foundation nvalls and columns to be centered on concrete feelings unless shown otherwise on plans. 3) All cast in place concrete must be trade with Portland cement and attain mini- mum compressive strength of 3000 psi after 28 days (minimum compressive strength of 4000 psi after 28 daps for concrete used in slabs). Design based upon BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318). 1999. Concrete placement to conform with - 'Construction Requirements'" as defined in ACI 318. All concrete slabs on grade must be provided control (scored or cut) in accordance with soils report. All exposed edges of concrete shall have %- chamfer. Concrete work shall not have an) horizontal cold joints unless au- thorized b) the engineer. Field coordinate all vertical cold joints with structural engineer. use continuous vertical water stop at all coldjoints. 4) Reinforcing steel is ASTM Grade 40. All welded wire fabric must conform to ASTM Alai. Reinforcement placement shall conform to MANUAL OF STAN- DARD PRACTICE. 2001 as prepared by CRSI. All lap splices to be nninnimum 36 bar diameters. all horizontal reinforcement to be continuous around corners and at wall intersections. Minimum reinforcement protection- - concrete poured against earth 3" - concrete poured in forms 2" - concrete slabs 1" i) All lumber shall be Doug -Fir #2 S4S or better, all wolmanized lumber shall be Hem -Fir #2 S4S or better (all lumber within 18" of finish grade or in contact with concrete must be wolmanized). Provide solid blocking at 8' -0 on center in all diaphragms. All columns to be continuous bearing to foundation. 6) Anchor bolts and bolts shall be A307 or better. 7) Sheath all interior clevatorwalls with' /" plywood with minimum span rating of 24/0 or better. Nail with 8d re 6" oc to all studs. 8) Live loads used for design- - Roof -100 psf snow (4:12 roof). -80 psf (8:12 roof). - Floor -40 psf residential. - Deck -100 psf. - Wind -90 ntplt (3 second gust). Exposure B. - Earthquake -Zone C -IBC. 9) All construction must compl}' with the 2009 International Building Code as adopted by the Town of Vail Building Department and the "General Conditions of the Contract for Construction' (AIA Document A201). All construction must be completed within the tolerances described in the "Residential Construction Per- formance Guidelines" as prepared by the NATIONAL ASSOCIATION OF HOME BUILDERS. 10) Construct wall as follows - - Exterior -2x6 tai. 16" oc. - Interior -2x4 im 16` oc. unless noted otherwise. 11) All beams. joists, and rafters are to bear upon walls or beams, or be hung with SIIv1PSON Strong -Tie hangers or approve equals. 12) All structural members are shown in their final positions properly braced and sup- ported; during construction it may be necessary to temporarily shore portions of the structure while other portions are being constructed. Contact the engineer for consultation as required. 13) General Contractor is responsible for all non - specified connections, contact engi- neer for details as required. The engineer is to approve all structural substitutions. 14) General Contractor is to coordinate all diaphragm penetrations (i.e.. chinucys. plumbing. sewers, etc.) through floors, walls. roofs and foundation walls NA 111i ap- propriate sub - contractors. General Contractor is responsible for the means, meth- ods. techniques. sequences. procedures. workmanship, seasonal scheduling and job -site safeh associated with this project. The General Contractor is to verify all dimensions and elevations with the architectural drawings. Notify engineer of all conflicts and omissions between various elements ofthe working drawings and the existing conditions prior to commencing with that portion of the project. General Contractor is to inspect remodel projects and verify prior use and proper disposal of existing materials (i.e.. asbestos. etc.) as required by code. Identity of all existing hidden structural members based upon visual inspection. 15) All materials exposed to exterior and or moisture conditions shall be treated for these conditions (i.e.. chemical treatment. staining, painting, damproofing, mem- branes. flashing. etc.) as required by code. All materials to be treated or protected for fire resistance as required by code. 16) Special inspection to be completed b)' building official approved inspection agenc) for poured -in -place concrete construction including reinforcing steel. and soils information. Inspection reports to be prepared in accordance with IBC Chapter 17 on approved foruts. verifying compliance with construction documents and be submitted to the building official for review and approval. copping the owner, general contractor and engineer. Coordinate inspections with general contractor so that special inspections can be periodic rather than continuous. 0 WALL LEGEND EXISTING WALLS TO REMAIN WALLS TO BE ADDED EXISTING JOISTS TO REMAIN M T ATE6 4 -2x1 �J 1 ry k n� C) 0• SECOND LEVEL FRAMING DENOTES 1/2" PLYWOOD GLUED AND NAILED TO FRAMING. I �F � N N �m I� J _1 N saw O :1 10 EDGE OF -. A CANTILE ` F, W 5 1 .. 0 I A-ZX6 I I Z NI x 0 N _ `" I INVERTED O 3 � 0 LU HANGER OR - I BOLTED LU CONN. PER o CONN.OTHER Q Q END OF BEAM N (2 TYPICAL) O > to O N I a°Er< O / EXISTING O = 2x12 RIM TO J Q m 0 O O REMAIN W W Z J o 0 to Q co X I (0 C) > w } w nO C� m UJ X I o J O w CN p C C [E a [E Cz L MAY 2 4 2011 C' t . 711 TOWN OF V 1/ = 1 1- S2 of 3 NI ,' ■ FIELD VERIFY EXISTING N HANGER WITH N UPLIFT CAPACITY EXISTING JOISTS TO REMAIN C? 9 � 4 „ L 5x5x1/4 w/ 2 - 3/4" 1 5�2" 3 3 �2 5' F_ DIA. M.B. THRU -5� 4 -2x12 AND 4 - 3/4" 0 DIA. M.B. THRU TREATED 4 -2x12 N 3 -2x12 (2 TYPICAL) TOP OF SLAB tr 5' -1" X v log 0 FIELD VERIFY = �" N ELE TO ao EXISTING _ HANGER WITH v _ " -5��8' _1 1' -1 UPLIFT CAPACITY r ,� ao ji/y9' =N N �EX. ISTI EAM TO REMAIN 0 WALL LEGEND EXISTING WALLS TO REMAIN WALLS TO BE ADDED EXISTING JOISTS TO REMAIN M T ATE6 4 -2x1 �J 1 ry k n� C) 0• SECOND LEVEL FRAMING DENOTES 1/2" PLYWOOD GLUED AND NAILED TO FRAMING. I �F � N N �m I� J _1 N saw O :1 10 EDGE OF -. A CANTILE ` F, W 5 1 .. 0 I A-ZX6 I I Z NI x 0 N _ `" I INVERTED O 3 � 0 LU HANGER OR - I BOLTED LU CONN. PER o CONN.OTHER Q Q END OF BEAM N (2 TYPICAL) O > to O N I a°Er< O / EXISTING O = 2x12 RIM TO J Q m 0 O O REMAIN W W Z J o 0 to Q co X I (0 C) > w } w nO C� m UJ X I o J O w CN p C C [E a [E Cz L MAY 2 4 2011 C' t . 711 TOWN OF V 1/ = 1 1- S2 of 3 71 nl' SHAFT DIMENSIONS 3/4" = 1' -0" OPEN _ EXISTING ROOF TO Rt . ED) _T w N o CV � M OD CV ABOVE WALL LEGEND EXISTING WALLS TO REMAIN --- WALLS TO BE ADDED TOP OF PLYWOOD 118' -2 1/2" oww/ \ ,' �I PER ii •• 11 i pr Lu w II F- U) X ui ,-57 8;' 2 1" 1' -107 'Z 3/2 6-5 9 1 / 4" O 1 LL&4 C) 03 LLJ owa- c: -o a o��� � SEE AR HITECTURAL PLANS nOR COMPACT MACHIN� ROOM SIZE AND LA OUT BENEATr BENCH .\ I 2.,0 / "a r EDGE OF CANTILEVER 2X6 LEDGER NAILED TO WALL M 5 y 2" THIRD LEVEL FRAMING DENOTES 1/2" PLYWOOD GLUED AND NAILED 1/4" = 1' -0" TO FRAMING. N ' N � o 0 E ^ <� N O o O 0 z o � 0 H �Q o ° > v Q 0 W CC W C� 0 > Lo 0= Q °cr< LLM C.3 Q W Wm o � � J Q Y Q 0 co (D ��� m T (� O [E c [E [E o a D MAY 2 4 2011 } . TOWN OF VAIL N S3 of 3