HomeMy WebLinkAboutDRB110134 Suszynski DRB SET 5-31-11 approved plans PROJECT NORTH DRIVEWAY EXPANSION FACADE REMODEL (2) SHED ROOF ADDITIONS (1) SHED ROOF ADDITION HOT TUB DECK ADDITION MATCH ASPHALT MATCH GRADE SEE SURVEY FOR RIDGE ELEVATIONS EXISTING PATIO NEW DECK ADDITION RAILING REMODEL HOT TUB 3' -7 11/16" 4' -8 3/8" 8439' -2" SNOW STORAGE NOTE: DRIVEWAY AREA EXISTING = 1,845 SQ. FT. NEW = 294 SQ. FT. TOTAL = 2,139 SQ FT. REQUIRED SNOW STORAGE AREA 30% OF TOTAL = 641 SQ. FT. PROPOSED AREA = 650 SQ. FT. SNOW STORAGE AREA SHOWN HATCHED CONTRACTOR TO BUILD DECK AROUND EXISTING TREES 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project numbe r Date REVISIONS 5/31/2011 7:28:58 AM 1481 Aspen Grove Lane Vail, CO 81657 A1.1 SITE PLAN + INFO 1105 Suszynski Renovation DRB SUBMITTAL SET 2 5-31-11 -1 1" = 10'-0" SITE PLAN LOT AREA = .587 ACRES x 43,560 SQ. FT. = 25,569 SQ. FT. SITE COVERAGE ALLOWED (20% OF SITE) = 5,114 SQ. FT. SITE COVERAGE PROPOSED = 1,935 SQ. FT ZONING SUMMARY GRFA PROPOSED: TOTAL =3,373 SQ. FT. (SEE SHEET A1.2 FOR CALCS) HEIGHT LIMIT = 33'-0" PROPOSED HEIGHT = 32'-9 1/2" PARKING SPACES REQUIRED: 3 SPACES PARKING SPACES PROPOSED: 3 SPACES Single Family Residence Owner: Conrad & Kristina Suszynski 2700 E Willamette Lane Greenwood Village, CO 80121 Location: 1481 Aspen Grove Lane, Vail, Colorado Lot 1, Block 2, Lions Ridge Filing 4 Parcel #: 2103-014-15-001 Class of Work: New Type of Construction: Type V-N Type of Occupancy: R3 (single family) Levels: 2-story +basement Martin Manley Architect -John G Martin PO Box 1587 Eagle, CO 81631 970.328.5151 ·GRFA ALLOWED : 25% lot area < 12,500 s.f. = 3,125 s.f. 10% lot area > 12,500 s.f. = 1,306 s.f. Total = 4,431 s.f. EXTERIOR: 1. (3) shed roof additions (within existing larger roof) 2. Change roofing material from cedar shingles to standing seam metal roofing. 3. Addition of large glass doors leading to existing patio -North Elevation. 4. Reconfigure Living Room windows and fireplace -South Elevation. 5. Reconfigure Master Bedroom windows -Upper Level -South Elevation. 6. Expand Dining Room (remove bay window) -West Elevation. 7. Replace front door with new custom door /sidelights. 8. Replace balcony railing -South Elevation. 9. New deck and railing w/sunken hot tub -West Elevation. INTERIOR: 1. Remodel Living Room, open up walls, and change location of fireplace. 2. Expand Dining Room and create more window area. 3. Replace and redesign entire Kitchen and add french door. 4. Re-design of entire east side of Main Level baths and closets. 5. Master Bath pop-up roof, remodel. 6. Master Bed -create walk-in-closet. 7. Stairs -straighten angled riser. GRFA CALCULATIONS BASEMENT CALCULATIONS: (SEE SHEET A1.2) TOTAL WALL SURFACE = 1,668 S.F. TOTAL EXPOSED WALL SURFACE = 726 S.F. PERCENTAGE EXPOSED WALL SURFACE = 43% PERCENTAGE UN-EXPOSED WALL SURFACE = 57% 1 -LIVING AREA -EXIST = 1,221 S.F. 1 -GARAGE -EXIST = 537 S.F. 1 -GARAGE DEDUCTION = (-537 S.F.) 1 -PRE-TOTAL = 1,221 S.F. BASEMENT DEDUCTION= (-525 S.F.) (43%) LEVEL 1 -GRFA TOTAL = 696 S.F. 2 -LIVING AREA -EXIST = 1,892 S.F. 2 -VAULTED 16' -EXIST = 48 S.F. 2 -LIVING AREA -NEW = 43 S.F. LEVEL 2 GRFA TOTAL = 1,935 S.F. 3 -LIVING AREA -EXIST = 673 S.F. 3 -LEVEL AREA -NEW = 21 S.F. LEVEL 3 GRFA TOTAL = 694 S.F. GRFA -EXIST = 3,309 S.F. GRFA -NEW = 64 S.F. TOTAL GRFA =3,373 S.F. VAULTED SPACES TALLER THAN 16'-0" = 48 S.F. Drawing List Sheet Number Sheet Name A1.1 SITE PLAN + INFO A1.2 AREA PLANS AND GRFA SUMMARY A2.1 Main and Upper Floor Plans A2.2 Roof & Lower Plans & model views A3.1 Exterior Elevations A3.2 Exterior Elevations A4.1 Building Sections A4.2 SECTIONS Grand total: 8 TOWN OF VAIL ZONING DISTRICT: SFR SINGLE-FAMILY RESIDENTIAL No. Description Date SETBACKS: FRONT = 20', SIDE = 15', REAR = 15' PROJECT /CODE SUMMARY PROJECT DESCRIPTION: TOPOGRAPHIC SURVEY (NOT TO SCALE) 1481 Aspen Grove Lane, Vail, Colorado Suszynski Renovation DN 1143 SF EXISTING LIVING AREA 78 SF EXISTING LIVING AREA 2 537 SF GARAGE AREA 1892 SF EXISTING LIVING AREA 15 SF NEW LIVING AREA 2 28 SF NEW LIVING AREA 1 695 SF EXISTING LIVING AREA 26 SF NEW LIVING AREA 48 SF 16' VAULTED AREA STAIR OPENING ON UPPER LEVEL DOES NOT COUNT FOR GRFA AREA OF "EXPOSED" WALL (RED) = 62 SQ.FT. AREA OF TOTAL WALL (HATCH) = 413 SQ.FT. AREA OF "EXPOSED" WALL (RED) = 24 SQ.FT. AREA OF TOTAL WALL (HATCH) = 371 SQ.FT. AREA OF "EXPOSED" WALL (RED) = 403 SQ.FT. AREA OF TOTAL WALL (HATCH) = 420 SQ.FT. AREA OF "EXPOSED" WALL (RED) = 237 SQ.FT. AREA OF TOTAL WALL (HATCH) = 464 SQ.FT. 1892 SF SITE COVERAGE -EXISTING 15 SF SITE COVERAGE -NEW 2 28 SF SITE COVERAGE -NEW 1 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project numbe r Date REVISIONS 5/31/2011 7:29:04 AM 1481 Aspen Grove Lane Vail, CO 81657 A1.2 AREA PLANS AND GRFA SUMMARY 1105 Suszynski Renovation DRB SUBMITTAL SET 2 5-31-11 -1 1/8" = 1'-0" 01.0 Lower Floor 2 1/8" = 1'-0" 02.0 Main Floor 3 1/8" = 1'-0" 03 Upper Level 4 1" = 10'-0" East Elevation -COPY 5 1" = 10'-0" North Elevation -COPY 6 1" = 10'-0" South Elevation -COPY 7 1" = 10'-0" West Elevation -COPY Area Schedule (16' Vaulted Area) Name Area Level 16' VAULTED AREA 48 SF 03 Upper Level 48 SF Area Schedule (Garage Existing) Name Area Level GARAGE AREA 537 SF 01.0 Lower Floor 537 SF Area Schedule (Living All) Name Area Level EXISTING LIVING AREA 1143 SF 01.0 Lower Floor EXISTING LIVING AREA 2 78 SF 01.0 Lower Floor EXISTING LIVING AREA 1892 SF 02.0 Main Floor NEW LIVING AREA 2 15 SF 02.0 Main Floor NEW LIVING AREA 1 28 SF 02.0 Main Floor EXISTING LIVING AREA 695 SF 03 Upper Level NEW LIVING AREA 26 SF 03 Upper Level 3877 SF Area Schedule (Living Existing) Name Area Level EXISTING LIVING AREA 1143 SF 01.0 Lower Floor EXISTING LIVING AREA 2 78 SF 01.0 Lower Floor EXISTING LIVING AREA 1892 SF 02.0 Main Floor EXISTING LIVING AREA 695 SF 03 Upper Level 3808 SF Area Schedule (Living New) Name Area Level NEW LIVING AREA 2 15 SF 02.0 Main Floor NEW LIVING AREA 1 28 SF 02.0 Main Floor NEW LIVING AREA 26 SF 03 Upper Level 70 SF 8 1" = 20'-0" 02.0 Main Floor Area Schedule (Site Coverage) Name Area SITE COVERAGE -EXISTING 1892 SF SITE COVERAGE -NEW 2 15 SF SITE COVERAGE -NEW 1 28 SF Grand total: 3 1935 SF No. Description Date DN DN DN DN DN REF. DW UP DN DN DN DN REF. DW DN DN 1 A4.1 1 A4.2 2 A4.2 3 A4.2 NEW SUNKEN ROUND CEDAR HOT TUB NEW DECK AND RAILING STEP UP NEW DECK EXISTING DECK NEW RAILING 5 A4.2 3' -0" 4 A4.2 11' -7 1/4" 14' -0 5/8" 3' -6" 10' -0" 2' -7 3/8" 25' -0" 4' -0" 12' -9" 10' -9" 9' -3" 11' -6" 27' -6" 1 A4.1 1 A4.2 2 A4.2 MASTER BEDROOM OFFICE MASTER BATH NEW HIGH WINDOWS NEW TUB NEW GLASS SHOWER EXIST VANITY LIGHT SHELF 3 A4.2 5 A4.2 NEW CLOSET 4 A4.2 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project numbe r Date REVISIONS 5/31/2011 7:29:08 AM 1481 Aspen Grove Lane Vail, CO 81657 A2.1 Main and Upper Floor Plans 1105 Suszynski Renovation DRB SUBMITTAL SET 2 5-31-11 -1 1/4" = 1'-0" 02 Main Floor -New 2 1/8" = 1'-0" 02 Main Floor Existing No. Description Date 3 1/4" = 1'-0" 03 Upper Level -New 4 1/8" = 1'-0" 03 Upper Level -Existing UP DN 16' -6" 13' -6" 17' -9" 17' -9" 1 A4.1 1 A4.2 2 A4.2 3 A4.2 5 A4.2 4 A4.2 NEW ENTRY DOOR WITH SIDELITES 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project numbe r Date REVISIONS 5/31/2011 7:29:24 AM 1481 Aspen Grove Lane Vail, CO 81657 A2.2 Roof & Lower Plans & model views 1105 Suszynski Renovation DRB SUBMITTAL SET 2 5-31-11 -1 1/4" = 1'-0" 04 Roof Plan -New 3 1/8" = 1'-0" 01 Lower Floor Existing No. Description Date 2 EXT -NORTH DECK -LOOKING SOUTH 4 EXT -FRONT ELEVATION-LOOKING NORTH 5 FRONT ISOMETRIC 6 REAR ISOMETRIC 02.0 Main Floor 8439' -6" 04 Roof Plate 8456' -6" 01.0 Lower Floor 8430' -6" 03 Upper Level 8448' -6" 9' -0" 9' -0" 8' -0" 26' -0" 1 A4.2 33' -0" 8463' -6" 8429' -6" MAXIMUM HEIGHT NOT TO EXCEED NEW BALCONY RAILING: AUSTRIAN STYLE 8" 12" 4" 12" 2" 12" NEW LIVING ROOM WINDOWS /DOORS NEW ENTRY DOOR /SIDELITES NEW SHED ROOF NEW ADDITION NOTE -RIDGE ELEVATIONS SEE "PEAK LAND CONSULTANTS" SURVEY DATED 4-13-11 5 A4.2 REMOVE CHIMNEY NEW SHED ROOF 02.0 Main Floor 8439' -6" 04 Roof Plate 8456' -6" 01.0 Lower Floor 8430' -6" 03 Upper Level 8448' -6" 1 A4.1 2 A4.2 3 A4.2 MASTER BATH DORMER NEW SHED ROOF NEW WALL /WINDOWS DINING ROOM ROOF NEW SHED ROOF NEW WALL /WINDOWS EXISTING CHIMNEY (ABANDONED) NEW METAL ROOF: STANDING SEAM DARK BRONZE COLOR NEW RAILING AUSTRIAN STYLE NEW DINING ROOM WINDOWS (RE-USE LIVING ROOM WINDOWS) NEW HOT TUB PATIO 4 A4.2 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project numbe r Date REVISIONS 5/31/2011 7:29:41 AM 1481 Aspen Grove Lane Vail, CO 81657 A3.1 A3.1 Exterior Elevations 1105 Suszynski Renovation DRB SUBMITTAL SET 2 5-31-11 -2 1/4" = 1'-0" South Elevation -NEW 1 1/4" = 1'-0" West Elevation -NEW 3 1/8" = 1'-0" South Elevation -EXISTING 4 1/8" = 1'-0" West Elevation EXISTING No. Description Date 02.0 Main Floor 8439' -6" 04 Roof Plate 8456' -6" 01.0 Lower Floor 8430' -6" 03 Upper Level 8448' -6" NEW SHED ROOF NEW WALL /WINDOWS SIDING & TRIM TO MATCH EXISTING 02.0 Main Floor 8439' -6" 04 Roof Plate 8456' -6" 01.0 Lower Floor 8430' -6" 03 Upper Level 8448' -6" 9' -0" 9' -0" 8' -0" 1 A4.22" 12" 2" 12" NEW NEW NEW DBL FASCIA (MATCH EXISTING) NEW SIDING /TRIM (MATCH EXISTING) NEW STUCCO (MATCH EXISTING) NEW SIDING /TRIM (MATCH EXISTING) 5 A4.2 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project numbe r Date REVISIONS 5/31/2011 7:29:57 AM 1481 Aspen Grove Lane Vail, CO 81657 A3.2 Exterior Elevations 1105 Suszynski Renovation DRB SUBMITTAL SET 2 5-31-11 -2 1/4" = 1'-0" East Elevation -NEW 1 1/4" = 1'-0" North Elevation -NEW 3 1/8" = 1'-0" East Elevation -EXISTING 4 1/8" = 1'-0" North Elevation -EXISTING No. Description Date 02.0 Main Floor 8439' -6" 04 Roof Plate 8456' -6" 01.0 Lower Floor 8430' -6" 03 Upper Level 8448' -6" 1 A4.2 4' -11" NEW WINDOWS NEW SHED ROOF NEW SHED ROOF EXIST BEAM 5 A4.2 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project numbe r Date REVISIONS 5/31/2011 7:30:01 AM 1481 Aspen Grove Lane Vail, CO 81657 A4.1 Building Sections 1105 Suszynski Renovation DRB SUBMITTAL SET 2 5-31-11 -No. Description Date 1 1/2" = 1'-0" Section 1 02.0 Main Floor 8439' -6" 03 Upper Level 8448' -6" 1 A4.1 2 A4.2 4 A4.2 02.0 Main Floor 8439' -6" 04 Roof Plate 8456' -6" 01.0 Lower Floor 8430' -6" 03 Upper Level 8448' -6" 1 A4.2 NEW WINDOWS 3' -0"16' -0" 5 A4.2 NEW SHED ROOF NEW WALL NEW CANTILEVER 02.0 Main Floor 8439' -6" 04 Roof Plate 8456' -6" 01.0 Lower Floor 8430' -6" 03 Upper Level 8448' -6" 1 A4.2 5 A4.2 02.0 Main Floor 8439' -6" 04 Roof Plate 8456' -6" 03 Upper Level 8448' -6" 4' -0" 8' -0" 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project numbe r Date REVISIONS 5/31/2011 7:30:07 AM 1481 Aspen Grove Lane Vail, CO 81657 A4.2 SECTIONS 1105 Suszynski Renovation DRB SUBMITTAL SET 2 5-31-11 -No. Description Date 1 1/4" = 1'-0" Section 3 2 1/4" = 1'-0" Section 4 3 1/4" = 1'-0" Section 6 4 1/4" = 1'-0" Section 12 5 1/4" = 1'-0" LIVING ROOM -FIREPLACE