HomeMy WebLinkAboutDRB100213 PlansCODE INFORMATION:
iaZ7 F INE AFA
2009
TWO FAMILY DWELLING - W1 FULLY OPERATIONAL SPRiNKER SYSTEM
SiTE CO V ERAGE-
LOT AREA = 21026 5F.
209. MAXIMUM = 5,257 5F.
PROP05ED TOTAL = 404 5F.
GROSS RESIDENTIAL FLOOR AREA (GRFA):
NOTE: ALL SF CALCULATIONS ARE TO OUTSIDE FACE OF STRUCTURAL FRAMING PLYWD. OR CONCRETE WALL.
RESIDENCE:
PRIMARY
SECONDARY
LOWER LEVEL
1388 S.F.
1359 5F.
ENTRY LEVEL
2555 5F.
GLB.
UPPER LEVEL
109 SF.
2061 S.F.
TOTAL
5040 S.F.
3420 5F.
GARAGE CREDIT
-600 S.F.
-600 SF.
TOTAL
44.40 SF.
2820 5F.
NOTE: RE: SF -1 FOR GFFA CALCULATIONS PER TiTLE 12, /
CHAPTER 15 OF
TOWN OF VAIL MUNICIPAL CODE j
�!
TOM JAFFE
1815 WEST GORE GREEK DRIVE,
APT E
VAIL, COLORADO 8165
TEL ("313) 7141 -1009
EMAIL: TOMJAFFE -aCOMCAST.NET
ABV
ABOVE
B.O.F.
BOTTOM OF FOOTING
DPR
DAMPER
FAB
FABRICATE
GLB.
GLASS BLOCK
LAV
LAVATORY
NT.S.
NOT TO SCALE
QTY.
QUANTITY
APP.
ABOVE FINISHED FLOOR
B.U.S.
BOTTOM OF STEEL OR BOTTOM
OP
DAtMPROOFING
F.B.
FACE BRICK
GLU -LAM GLUE-LAMiNATED TIMBER
L.H.
LEFT HAND
NO.
NUMBER
Q.T.
QUARRY TiLE
A.S.G
ABOVE SUSPENDED
SYNTHETIC
OF SLAB
D.L.
DEAD LOAD
F.O.
FACE OF
G.B.
GRAB BAR
L.H.R
LEFT HAND REVERSE
TOP OF SLAB
TA.STL.
TOP OF STEEL
T.O.UI.
TOP OP WALL
CEILING
B.O.W.
BOTTOM OF WALL
DEG
DEGREE
F.00.
FACE OF CONCRETE
GR
GRADE, GRADING
L
LENGTH
TYPICAL
SANITARY SEWER
88
W/O
ACC
ACCESS
B.T.U.
BRITISH THERMAL UNIT
DIEM
DEMOLISH, DEMOLITION
F.OF.
FACE OF FINISH
GF.RC.
GLASS FIBER REINFORCED
LW
LIGHTWEIGHT
OBS
OBSCURE
G
GAS LINE
A.P.
ACCESS PANEL
15RZ
BRONZE
DMT
DEMOUNTABLE
FD.M.
FACE OF MASONRY
GLEAN OUT
CONCRETE
LWC
LIGHTWEIGHT CONCRETE
OC.
ON CENTER (S)
RBT
RABBET, REBATE
AC
ACOUSTICAL
BLDG
BUILDING
D
DEPTH, DEEP
F.O.S.
FACE OF STUDS
GVL
GRAVEL
LMST
LIMESTONE
OFIG
OPENING
RAD
RADIUS
ACT.
ACOUSTICAL TILE
Bid.R.
BUILT UP ROOFING
D.RB.
DESIGN REVIEW BOARD
PAS
FASTEN, FASTENER
GRID
GROUND
L.F.
LINEAL FEET
O.JST.
OPIEN -WEB JOIST
RR
RAILROAD TIE (TIMBER)
ACR.
ACRYLIC PLASTIC
0 10 20 40
DTL
DETAIL
FND.
FEMININE NAPKIN DISPENSER
GT
GROUT
LNTL
LINTEL
OPP
OPPOSITE
RWC
RAINWATER CONDUCTOR
ADD
ADDENDUM
D►AG
DIAGONAL
FNP.
FEMININE NAPKIN t
ACLE RECEP
GA
GUAGIE
O
OPPOSITE HAND
RC
REC EPTACLE
ADN
ADDITIONAL
DAM
DIAMETER
FN
PENCE
GYP
GYPSIitM
LVR
LOUVER
O D.
OUTSIDE DIAMETER
R
RE 7D
ADH
ADHESIVE
CAB
CABINET
DIM
DIMENSION
FGL
rIBER3LASS
OUTSIDE FACE STUD WALL
RE:
RIE
REFERENCE, REFE R T
ADJ
ADJACENT
CAD
CADMIUM
OW
DISHWASHER
F.Y.
FIELD VERIFY
O/O
0/0
OUT 7O OUT
�
(C7<J
REFLECT ( IvE),
ADJT
ADJUSTABLE
CANT
CANTILEVER
OtS
DISPOSAL
FN
FINISH (ED)
HBD
HARDBOARD?
MH
MANHOLE
OA
OVERALL
REF RIGERATOR
A
AGGREGATE
CPT
CARPET (ED)
DIV
DiV15ION
FF.
FINISHED FLOOR
HDW
HARDWARE
MFR
MANUFACTURE (ER)
OH
OVERHANG, OVERHEAD
REG
REGISTER
A /C
AIR CONDITIONING
CSMT
CASEMENT
DR
DOOR
FA.
FIFE ALARM
HWD
HARDWOOD
MRB
MARBLE
RIEINP
REINFORCE mw (UING)
ALM
ALARM
C.I.P.
CAST -IN -PLACE
OBL
DOUBLE
F.BRK.
FIRE BRICK
HD
HEAD
M.T.
MARBLE TILE
RCP
REINFORCED GGNCRETE PIPE
ALT
ALTERNATE
C.I.
CAST IRON
DA
DOUMEACTING
P.E.
FIFE EXTINGUISHER
HDR
HEADER
M
MASONRY
(R)
REMOVE
AL
ALUMINUM
C.B.
CATCH BASIN
D.H.
DOUBLE HUNG
F.E .C.
FIRE EXTINGUISHER CABINET
HTR
HEATER
MA.
O.
MASONRY OPENING
(P)
PAINT (ED)
REQ
REQUIRED
AMERICAN CONCRETE
(C)
CAULK (ING)
DTA.
DOVETAIL ANCHOR
F.H.C.
FIRE HOSE CABINET
HTG
HEATING
MAiL
MA (S)
P R
PAIR
RESIL
RESILIENT
INSTITUTE
CDR
CEDAR
DN
DOWN
FM
FIREPLACE
HVAC .
HEATiNG/YENTILATING / AIR
MAX
IMUM
MAXIMUM
PNL
PANEL
RET
RETURN
AIA
AMERICAN INSTITUTE OF
CLG
CEILING
DS
DOILNSPOUT
P.Y.G.
FIRE VALVE CABINET
CONDlTIONtNG
MECH
MECHANICAL
P.B.
PANiC BAR
RA.
RETURN AIR
ARCHITECTS
CEM
CEMENT
DRN
DRAIN
FP
FIREPROOF
H.D.
HEAVY DUTY
M.C.
MEDICINE CABINET
P.ID.
PAPER TOWEL DISPENSER
REV
REVERSE, REVISION
AI.SC.
AMERICAN INSTITUTE OF
C
CENTIMETER (5)
DR.BD
DRAINAGE BC4RD
F.R.fi.
FIRE-RESISTANT TREATED
H7
HEIGHT
MED
MEDIUM
P.T.R.
PAPER TOWEL RECEPTOR
RH,
RIGHT HAND
STEEL CONSTRUCTION
C.M.T.
CERAMIC MOSAIC TILE
D.T.
DRAIN TILE
F.R.C.
FIRE- RETARDANT
H C.
HOLLOW CORE
MBR
MEMBER
PAR
PARALLEL
RAW.
RIGHT OF WAY
ANS.i.
AMERICAN NATIONAL STANDARDS
C.T.
CERAMIC TiLE
DWR
DRAWER
FIX
FIXTURE
HM
HOLLOW METAL
MB
MEMBRANE
P.BD.
PARTICLE BOARD
R
RISER
INSTITUTE
CHAM
CHAMFER
DUX ;
G
DRAWING
FLASHING
H(ORJ
HORIZONTAL
MTL
METAL
PTN
PARTITION
RD.
ROOF DRAIN
A.STM.
AMERICAN SOCIETY FOR TESTING
CHR
CHROMIUM (PLATED)
D.F.
DRINKING FOUNTAIN
PL X
FLEXIBLE
HS.
HOSE BIB
MTFR
METAL FURRING
PVMT
PAVEMENT
RF.H.
ROOF HATCH
AND MATERIALS
CiR
CIRCLE
D.W.
DUMB WAITER
FLR
FLOOR (IN1Gx)
HWId.
HOT WATER HEATER
M.RD
METAL ROOF DECKING
PED
PEDESTAL
SM
ROOFINGS
A.D.A.
AMERICANS WITH DISABILITIES
CiRC
CIRC 1FF-RENCE
PL.CO.
FLOOR CLEANOUT
M
METER (5)
PEND
PENDANT
R.O.
ROUGH OPENING
CL.
CLEAN OUT
F.D.
FLOOR DRAIN
MEZ
MEZZANINE
PEW
PERFORATE (D)
AWES.
AMERICAN WIRE GUAGE
CLR
CLEAR (ANCE)
F/L
FLOOR LINE
INCL
INCLUDE (D), (ING)
MM
MILLIMETER (S)
PER
PERIMETER
R.S.
ROUGH SAUNN
ANC
ANCHOR, ANCHORAGE
CLOS
CLOSET
RM.
FLOOR PLATE
INFO
INFORMATION
MW<
MILLWORK
PH
PHASE
R.B.
RUBBER BASE
A.B.
ANCHOR BOLT
CLS
CLOSURE
FLUOR
FLUORESCENT
I.D.
INSIDE DIAMETER
MIN
MINIMUM
PLS
PLASTER
R.T.
RUBBER TiLE
ANOD
ANODIZED
GIU.
COLD WATER
PIT.
PLUSH JOINT
I.BC.
INSTALLED BY CONTRACTOR
MIR
MIRROR
PLAS
PLASTIC
APPD
APPROVED
COL
COLUMN
EA
EACH
FTG
FOOTING
T.B.O.
INSTALLED BY OTHERS
MISC
MISCELLANEOUS
PLAM.
PLASTIC LAMINATE
APP
APPROXIMATE
COMB
COMBINATION
EF.
EACH PACE
Fps
FORGED
INSUL
INSULATE (D), (ION)
MOD
MODULAR
PL
PLATE
SFLSL
SAFETY GLA55
ARCH
ARCHITECT WRAL)
COMPT
COMPARTMENT
EW.
EACH WAY
FDN
FOUNDATION
:NT
INTERIOR
MLD
M
P.G.
PLATE GLASS
SDST
SANDSTONE
AD
AREA
COMP
C
COMPOSTION (COMPOSITE)
Ep
ELECTRIC
FR
FRAME (D), (IWW
INTM
INTERMEDIATE
MT
MOUNT )
P/L
PLATE LINE
ALT
AUTOMATIC TIC
COMPR COMPRESS (ED), (ION), (ISLE)
EF'.
ELECTRICAl-
L P ANIELBOARD
FRR P
FREEZE PROOF
INV
INVERT (ED)
MTD
MOUNTED
PLY
PLYWOOD
S )
SEALANT
AVG
AVERAGE
CONC
CONCRETE
E.W.C.
ELECTRIC WATER COOLER
FA.
PRESH AIR
MOV
MOVABLE
PKT
POCKET
STG
SEATING
C.M.U.
CONCRETE MASONRY UNIT
EL
ELEVATION
F.I.O.
PURNISHED AND INSTALLED
MUL
MULLION
PT
POINT
SECT
SECTION
BSh?T'
BASEMENT
COW
CONNECTION
ELEv
ELEVATOR
BY OTHERS
J.C.
JANITOR'S CLOSET
N.E.G.
NATIONAL ELECTRIC GORE
PVC.
POLYVINYL CHLORIDE
SHTG
SHEATHING
BM
BEAM
CONST
CONSTRUCTION
EMER
EMERGENCY
F.B.a.
FURNISHED BY OTHERS
JT
JOINT
NF.PA.
NATIONAL FiRE PROTECTION
P.E.
PORCELAIN ENAMEL
SHT
SHEET
BRIG
BEARING
CS.i.
CONSTRUCTION
ENCL
ENCLOSE (URE)
FUR
FURRED (ING)
JP.
JOINT FILLER
ASSOCIATION
POS
POSITIVE, POSITION
S1MA
SHEET MEMBRANE ROOFING
BEL
BELOW
SPECIFICATIONS INSTITUTE
EQ
EQUAL
PUT
FUTURE
NAT
NATURAL
P.TC.
POST TENSIONED CONCRETE
SMACNA. SHEET METAL 4 AIR
BET
BETWEEN
CONT
CONTINUOUS OR CONTINUE
EQUIP
EQUIPMENT
(N)
NEW
LB
POUND
CONDITIONING CONTRACTORS
BVL
BEVELED
CONTR
CONTRACT (OR)
EST
ESTIMATE
KP
KiCKPLATE
N.R
NOISE REDUCTION
P.C.F.
POUNDS PER CUBIC FOOT
NATIONAL ASSOCIATION
BIT
BITUMINOUS
CJ.
CONTROL JOINT
EXC
EXCAVATE
KIT
KITCHEN
N12C.
NOISE REDUCTION
PJ.F.
POUNDS PER LINEAL FOOT
SM.
SHEET VINYL FLOOR COVERING
BLK
BLOCK
CPR
COPPER
EXH
EXHAUST
GPM.
GALLONS PER MINUTE
KO
KNOCKOUT
COEFFICIENT
P.51=.
POUNDS TER SQUARE FOOT
SIM
SIMILAR
5LK13
BLOCKING
COR
CORRUGATED
(E)
EXISTING
GALV
GALVANIZED
NOM
NOMINAL
P.S.I.
POUNDS PER SQUARE INCH
S.H.
SINGLE HUNG
BD
BOARD
CTR
COUNTER
E.B.
EXPANSION BOLT
G.I.
GALVANIZED IRON
N.C.
NON - CORROSIVE
PGC.
PRECAST CONCRETE
SKY
SKYLIGHT
B.S.
BOTH SIDES
CS
COUNTERSINK
EXP
EXPANSION
G.S.S.
GALVANIZED STEEL SHEET
LBL
LABEL
RMT.
NON METALLIC
PREFAB PREFABRICATE (D)
SL
SLEEVE
B.W.
BOTH WAYS
CRS
COURSE (S)
E.J.
EXPANSION JOINT
GSKT
GASKET (ED)
LAB
LABORATORY
(NP.)
NO PANT
PPN
PREFIN16HED
S.J.
SLIP JOINT
WT
BOTTOM
CRG.
CROSS GRAIN
EXT
EXTERIOR
GEN
GENERAL
LAD
LADDER
NA.
NOT APPLICABLE, ( AVAILABLE)
PSC.
PRESTRESSED CONCRETE
S.B.
SOLID BLOCKING
B.O.B,
BOTTOM OF BEAM
C.F.
CUBIC FOOT
E.IF.S.
EXTERIOR INSULATION AND
GC.
GENERAL CONTRACT (OR)
L.B.
LAG BOLT
N.I.
NOT INCLUDED
PROP
PROPERTY
S.C.
SOLID CORE
BAC.
BOTTOM OF CONCRETE
C.Y.
CJBiC YARD
FINISH SYSTEM
GL
GLASS, GLAZING
LAM
LAMINATE (D)
N tC.
NOT N CONTRACT
PL.
PROPERTY LiNE
SP
SOUNDPROOF
1'1ATERiAL. 5`'I�5OL 5
SPKR
SPEAKER
SPEC
SPECIFICATION (S)
SPG.PT
SPRING POINT
SQ
SQUARE
SF.
SQUARE FOOT (FEET)
ST.S
STACKED STUDS
S.S.
STAINLESS STEEL
STD
STANDARD
STA
STATION
STL
STEEL
ST
STONE
STOR
STORAGE
SD.
STORM DRAIN
STR
STRUCTURAL
5U5P
SUSPENDED
SYM
SYMMETRY OCAL)
SYN
SYNTHETIC
SYS
SYSTEM
TKBD
TACKBOARD
TEL
TELEPHONE
TV
TELEVISION
TEMP
TEMPERED, TEMPERATURE
T.C.
TERRA COTTA
TZ
TERRAZZO
THK
THICK (NESS)
THR
THRESHOLD
T.P.
TOILET PAPER HOLDER
TF'TK
TOILET PARTITiON
TOL
TOLERANCE
TtG
TONGUE AND GROOVE
T45
TOP AND BOTTOM
T.O.B.
TOP OP BEAM
T.O.G.
TOP OF CONCRETE
TAD.
TOP OF DRAIN
T.OF
TOP OF FOOTING
TAM,
TOP OF MASONRY
T.O.PL
TOP OF PLATE
TA.PLY.
TOP OF PLYWOOD
TA.R
TOP OF RIDGE
T.O.S.
TOP OF SLAB
TA.STL.
TOP OF STEEL
T.O.UI.
TOP OP WALL
TL,D.
TOTAL LOAD
T.B.
TOWEL BAR
T.L.
TRACK LIGHTING
TR
TR448
T
TREAD
TYP
TYPICAL
UC
UNDERCUT
UG
UNDEFCsROIAdD
U.L.
UNDERWRITERS LABORATORIES
UNP
UNFINISHED
&ITN PLAN 5'T 50L.
SHEET NLMBER
E3UILI_>iNCz av1=CT10N
C3=LE ION) ��
PLAN # SECTION
EXISTING
r=3= 4Tt "' _ ._. _..._ _
1EXISTiNCz
PE.4TUIRE
Pt�OF C'C�3t^TD
VENEER
V.T.R.
tms�
�
VERIFY
V.IF.
--- -°-"""
CONTOUR
- --"°'
V.S.J.
5PC>T 1rL�Y4TrQN
VEST
- -
f=ROP1 =1;;ZTY LINE
- -
VL.B.
+-IYi_>R4NT
VCT.
-
C=ENTER LINTS
-
V.T.
Y,4LY4
--0--
- - - ---
M TU
V -JOINT (ED)
-e-
UTILITY POL3=
---
�
WALL HUNG
t
WALLPAPER
W.TW.
fiR.4NSFOt�'tSR
■
WATER CLOSET
FI=NCE
WATERPROOFING
-�}
LIGHT
#
ST
STORM DRAIN
ST
WWF.
WELDED WIRE FABRIC
WH.B.
WHEEL BUMPER
W
WIDTH, WiDE
�-
SIGN
WG.
WIRED GLASS
SANITARY SEWER
88
W/O
MONUMENT
0
w
WATE=RLINE
w
OR
METER PiT
O
8
ELECTRIC LINE
E
O
MANHOLE
0
G
GAS LINE
G
�
CATCH f5AS iN
4
T
fiELEPHONE LiNG
T
0
GLEAN OUT
•
-uTV
CAE3LE TELEVISION
-CTV
OUTFALL /HEADWALL
h
_--
DRAINAGE LINE
••"
E MNCHMARK
LIMIT OF UJORI<
PLM "A"
Ir
- -
E30RiNCx LOCATION
MATCI -I LINE
X
1EXISTiNCx TREE
PLAN "so
TREE: TO E5E REMOVED
�
TRfANGsULAfitON POiNT
0 10 20 40
GRAPHIC SCALI=
NORTH ARROW ia
NORTH
WALL 9E CTIC7N
t71 =TAI1_ BLOWUP
DETAIL CUT
ELE VATIONe
RELATEt a
DETAIL CUT
BELOW OR ABOVE
AREA of CUT
DETAIL NUMBER
Alm SHEET NUMBER
Al2
5
A"I
SIMILAR DETAIL
DETAIL NUMBER
NUMBER
Al2 A32 ( SHEET NUMBER
T SC SHEET
R
STRUCTURAL EWG INNER LANDSCAME DESIGNER GENERAL CONTRACTOR
CREATIVENVIRONMENT5 5UNDER, INC.
PO 50 X 5313 PO SOX 1393
V AiL, COLORADO 81658 EDWARDS, COLORADO 81632
TEL (910) 904 - 0600 TEL ( 3W -1888
CONTACT: CHARLES HARRiSON FAX 0910) 926 - 1932
EMAIL: CHARRI50NaGE- LAND6CAPE.COM CONTACT: J.P. 5UNDERLAND
EMAIL: 5UNDERQ VA i L.NET
ARCHITECTURAL 5'1' 5OL.5
ROOM NAME, LIVIf4a N ROOM NAME
AD N NUMEE
3R 1=2 151 uts C-
WiTH FINI
FLOOR
BASE
WALLg
CEILING
(CEILING Ht
IF USED)
WALL TYPE t0
MARK
DOOR MARK
WINDOW MARK 0
REVISION A
INDICATION
DESCRIPTION OF
ELEVATION!
ELI=VATtON T OP OF t =i.Ywraora
MARK
ELEVATION!
DRAWING NUMBER
I�RAwlt�1G TITLE
1/4" - 1' - to ll
SCALE
� �'-
-"ILA 12 11_
d � Ixt
s POROUS FiLL
' TOP °SOIL
ASPHALT PAVING/
M. P :? ROAtDBED MAT'L
STONE VE=NEER
F-r CAST iN PLACE
CONCRI=fiB
PRECAST CONCRETE
CONCRtETE E3LOCK
STE:3 =L CLC-t_ SCALE= )
C = YPSUt 1 IBOARt CL(S- SCALI=.)
1ELE iON
V.B.
VAPOR BARRIER
VAR
VARNISH
\INR
VENEER
V.T.R.
VENT THROUGH ROOF
(V)
VERIFY
V.IF.
VERIFY IN FIELD
VERT
VERTICAL
V.S.J.
VERTICAL SLIP JOINT
VEST
VESTIBULE
VIN
VINYL
VL.B.
VINYL BASE
VCT.
VINYL COMPOSITION TILE
VF.
VINYL FABRIC
V.T.
VINYL TILE
VWC.
VINYL WALL COVERING
V.J.
V -JOINT (ED)
WSCT
WAINSCOT
W.H.
WALL HUNG
WPR
WALLPAPER
W.TW.
WALL TO WALL
W.C.
WATER CLOSET
WP
WATERPROOFING
W.R.
WATER REPELLENT
WS
WATERSTOP
WT
WEIGHT
WWF.
WELDED WIRE FABRIC
WH.B.
WHEEL BUMPER
W
WIDTH, WiDE
WDO
WINDOW
WG.
WIRED GLASS
W/
WITH
W/O
WITHOUT
WD
WOOD
W.B.
WOOD BASE
W.PT.
WORKING POINT
W11.
WROUGHT IRON
<
ANGLE
It
CENTER LINE
CHANNEL
}t5
PROPERTY LINE
ROUND / DIAMETER
4
SQUARE
X
DEGREE
#
NUMBER
1_
- PLYWOOD
°
F►NISI -f U1G7cDD
UNIFORM MECHANICAL CODE
ROUC -%H WOOL7/
�
l /
CONTINUOUS
°
ROUGH WOOD/
-
DISCONTINUOUS
SAND, PLASTER
EsATT ►NSULATiC7N
RtCs(L7 INSULATION
;t NEW STUN
EXISTiNGc TO REMAIN
- - - - REMOVE EXISTING
i i I WOODS►D►NG ° - WOOD
CONCRETE,
STUCCO
IND TO ORA�UII�G
A1.0 COVER SHEET
ARCHITECTURAL
A2.0 SiTE 4 GRADING PLAN
A3.0 PRIMARY UNiT - L O WER LEVEL FLOOR PLAN
A31 PRIMARY UNiT - ENTRY LEVEL FLOOR PLAN
A3.2 PRIMARY UNiT - UPPER LEVEL FLOOR PLAN
A3.3 SECONDARY UNIT - LOWER LEVEL FLOOR PLAN
143.4 SECONDARY UNiT - UPPER LEVEL FLOOR PLAN
A4.0 ROOF PLAN
A5.0 5UiLDING ELEVATiON5
Aa.1 5UiLDING ELEVATIONS
A5.2 BUILDING ELEVATIONS
A53 5UILDING ELEVATIONS
5F -1 SQUARE FOOTAGE AND SiTE CO V ERAGE CALC5.
GENERAL NOT E6
NER1L NOTESs
1, ALL DIMENSIONS ARE TO FACE OF STUD OR CONCRETE,
UON. ALL EXTERIOR WALLS TO 5E 2x6, UON. ,ALL INTERIOR
WALL ARE 2x4, UON.
2. ALL FIREPLAC TO MEET LOCAL AND STATE CODES
INCLUDING ALL ACCESSORIES, FIRE RATINGS, ETC.
3. GANG TOGETHER VENT 5TACK5 AS MU A5 P055i5LE
TO MINIMIZE ROOF PENETRATIONS.
4, PROVIDE ELECTRICAL HEAT TAPE FOR ALL GUTTERS,
DOWN5POUT5 AND OTHER PIPES AS REQ UIRED.
5. CONTRACTOR TO COORDINATE ALL DE51GNl5UILD
MECHANICAL AND ELECTRICAL EQUIPMENT, DEVICES AND
WORK. ALL MECHANICAL, ELECTRICAL 4 FIRE PROTECTION
TO 5E DE5iGN15UILD. 5U5MIT DRAWINGS FOR REV 5`fi'
ARCHITECT.
6. RE: A5.0 FOR WINDOW AND DOOR SCHEDULES.
1. EL EVATI O NS SHOWN ARE T.O. PLYWOOD UNLESS
OTHERWISE NOTED.
5. ALL ERRORS, OMISSIONS OR CONFL I CTS FOUND iN THESE
DOCUMENTS SHALL 5E 5ROUGHT TO THE ATTENTION OF THE
ARCHITECT 5EFORE PROCEEDING WITH THE WORK,
9. PROVIDE AND LOCATE ATTIC VENTING AS REQUIRED 5Y
CODE,
10. DOOR SCHEDULES IN THiS PACKAGE SET INDICATE 61ZE
AND TYPE FOR FRAMING INFORMATION ONLY. FURTHER
INFORMATION A5 TO WOOD SPECIES, FiNiSH AND SPECIAL
REQUIREMENTS TO 5E SELECTED 5`'r' OWNER AND INTERIOR
DESIGNER.
11, PROVIDE ATTIC ACCE56 PANEL5 AS REQUIRED 5Y
5UILDING INSPECTOR. COORDINATE LOCATIONS WITH
ARCHITECT.
12. PROVIDE AND COORDINATE LOCATIONS OF BLOCKING
WITH INTERIOR DESIGNER'S BATHROOM ACCESSORIES
SELECTIONS AND LAYOUT.
C� 2010 SNIA
VI MAP
1BUIL1:71N(:5r 81 °CTIC)N 2 2 - BUILOW3 SECTION
(PLAN,) 1s,r- NUMBER
�ITd�
6EGER5ERG MAYHEW
4 A550CIATE6 ARCHITECTS
101 EAGLE ROAD - BUILDING 6
AVON, COLORADO 81620
TEL ( 416 -4433
FAX (9'0) 4"6 -4608
CONTACT: KURT 6EGER5ERGI5ARAH
EMAIL: K5EGER5ERG
SM I KKE L SEN e SMARCHS.GOM
•
& Ilk
A" 11 = to
LOT 3 GLE-N- LYON SUBDIVISION
VAIL, CO ORADO
U.B.C.
UNIFORM BUILDING CODE
UM.C.
UNIFORM MECHANICAL CODE
U.P.C.
UNIFORM PLUMBING CODE
U.O.N.
UNLESS OTHERWISE NOTED
URN
URINAL
Se ger b erg
Ass
1 s �
r •r' #
101 Eagle Road - Building 6
Avon, CO 81620
Tel: 970.476.4433
Fax: 970.476.4608
info @smarchs.com
www.smarchs.com
Drawing Title:
COVER SHEET
Date: 00-14 -10
P roject No: 33006.00
Drawn by: SMK
Checked by: K5
Sheet:
owl
rR �
�- Iw
CID
f '
u l
>
Drawing Title:
COVER SHEET
Date: 00-14 -10
P roject No: 33006.00
Drawn by: SMK
Checked by: K5
Sheet:
owl
1.
2.
3.
4.
7.
NOTI
56.2
Qt
6
- -------- ---
I
11
T — 5 -
33
30
j
9
--
10
-
4
c e
F
-F.
F
e n c e
F
.- F
S. F,
r////////A TOTAL IRRIGATED AREA 1038
Ir
& Associates Architects
TC
DF
E4
A=105*54'1
R=20.00'
L=36.97'
101 Eagle Road - Building 6
Avon, CO 81620
Tel: 970.476.4433
Fax: 970.476.4608
info@smarchs.com
www.smarchs.com
40
t]
Drawing Title:
SITE AND GRADING PLAN
5HEET NOTE,5•
1. VERIFY TOPOGRAPHY INFORMATION 5HOWN ON TH15 51TE PLAN WITH EX15TING CONDITIONS FOR
ACCURACY.
2. REFER TO SHEET A1.0 FOR GENERAL NOTE5.
3. REFER TO 5TRUCTURAL FOR ALL RETAINING WALL5.
4. REFER TO LANDSCAPE DRAWING6 FOR PAVING MATERIAL AND PROP05ED VEGETATION.
COORDINATE IRRIGATION 6LEEVE5 PRIOR TO PAVING IN5TALLATION.
ti
ti
6mmpmffm� FLAN
0 2.5' 10 NORTH
125 51
C@ SMA
Date: 06-14-10
Project No: 3300(o.00
Drawn by: 6m<
G
0 0 0
ot d, 51 01
I -- — — — — — — — — — — — — — — — — — — — — — — — — — — — --------- - - - - -- ------- - - - - -- -
------- 7T ------------ 1-1 ---------
F OVE
JF
fF
w. j
--- j \
REF.
rT
J.—
7 - — — — — — —
0 j - �_ i j , ° ° -1
Y
7 T — — — — — — 7
T
\ V ., r ( ! I 1 ) I j (� j I ( ; __�. �_� I ___. _ \\ t �_ <����j\jj \ >
D
HEAT-N-GL6 BOX jj _ _ � \T
F-A
i L I ( \ �I � � � � - I WITH GAS U
SET (EXCLAIM I . .....
50) WITH 7,
-------- 1 - T I __ T.,__�____ � .__�jj =� j,, ___- �����' hj� `�� 1 j� V A v t
- A
ELECTRONIC LL-k-JIT
X
L ------- J
DAMPER AT! TOP
5ECONDARY RE61DENC-
fQH
I _ L ____ ----------
RE
\ j j� j -- j --- L - - - - -- � ��1— A3.4
ILI—
7 :
-
F x, !�� . r, jj.
F
PANTRY
`-&ItTIN M/
I 1V
< >
'N� /
GREAT ROOM . .....
71
3131'_0"x26' - 6" U \\ % �� ja _ - -I \ -- ! I j \ L
0
-J-
7 _. j j� , j �� I .
wo
-4-
"T
— -------- --
k BAR
T
- AL0
EX E
� A \ "`. _...= / � w / � � % \ � _.- �-_.�% �_ -..__ � l � % i_� � � � — � — �� t4T� '4 � — n �.,. t _f i � ___ �. _. _.--- __,_ _ a ���` � ` �� ! \, j �'� � A t (�j
\ r i� 1 \ c T j j GARAGE
TYF
23
r l ;�� �j�` � j,, \� , af ENTRY jj .j` \``` I
GRILL
v ,° / —j _s j j-- j j j "-AT[ ❑ P ��
�� r - � �y -- �_� j v � � � j = j� 71 _ �-j ,' ��j j . _., '�.� � �j�
AL ��
Z' I\ 7 it � �-- � _ -_- - *`-\ �
Y
J�
\1K GAS METER
LOCATION
� `~ — "..,�. '' �'� � i, R�'�° \ � b � a' j � �\ r " "� � � ✓ � \�\ \ V
�19
GA L
�, j = 'IT j j- j / j 1, r
I m
oil
_ j
'X V-0" ,` f %� t ,
'�- 1 � j �, j � \ �, � ' '� jj .. \_.�.rr .� -� j� Ag j , t "� v y �, y , j ��� � _� jyy � , �� y j
.3
J 0
V
j o , � oi l
TRENCH DRAIN
ELECTRICAL
METER LOCATION
FLAGSTONE '
.
WALKW Y
7 t
� �� �j \\ ti��._ ajj�
HEATED
CONCRETE
DRIVEWAY
o 1 2 41 81 FL AN
NORTH
PRIMARY RESIDENCE
41
ENTfR`r LEVEL FL OCR FLAN
SCALE: 114" = 1'-0"
0 201 0 SMA
Segerberg Mayhew 'I
• Associates Architects
P.C.41-4-
-0 5 AN
101 Eagle Road - Building 6
Avon, CO 81620
Tel: 970.476.4433
Fax: 970.476.4608
info@smarchs.com
www.smarchs.com
Revisions:
06-14-10 DRB 5U5MITTAL
6-30-10 E)RE3 COMMENT6
Drawing Title:
PRIMARY RESIDENCE
ENTRY LEVEL FLOOR PLAN
ate: 0e,14-10
Project No: 3300(o.00L
Checked by: K5
Segerberg Mayhew
♦ Associates Architects
P.C.-A.I.A.
W = - = - - • I -
• W-jefel fam In I C1 - ,4 mm
101 Eagle Road - Building 6
Avon, CO 81620
Tel: 970.476.4433
Fax: 970.476.4608
info@smarchs.com
www.smarchs.com
Revisions:
i. AM
WAN " 0 0
Drawing Title:
BUILDING ELEVATIONS
Date: Oro-14-10
SCALE: 1/4" = I'-0
Win
SYNTHETIC
SHAKE ROOFING
LITI'mm"
•
4-.�
INSIZL-J��
PAINTED METAL
RAILING
STANDING SEAM
METAL ROOFING
J
- j-
T.O. CHIMNEY
T
RIDGE
- ------- - ------
8
r.
it
-J
ii
-J -
4
L
j- A
i f t
X
L d 1 LA I-,
J
L
7 ,
41 T-
- i T I F! { ^ i � i { ' i { � 1 i ! � ! i {, ,,� __ _, - - __.t- .-i_�- _1- i_w�.. � --s
if
(0
------ ------
J1. —A
J
STUCCO
II
All
I
- - - -- - - - - - - -
IC
1
i ,,i
RIDGE
I
MR
F
g
it
r
a104 _all
12
A
J
J L--�
IL
T.O. CHIMNEY
T
RIDGE
- ------- - ------
8
r.
it
-J
ii
-J -
4
L
j- A
i f t
X
L d 1 LA I-,
J
L
7 ,
41 T-
- i T I F! { ^ i � i { ' i { � 1 i ! � ! i {, ,,� __ _, - - __.t- .-i_�- _1- i_w�.. � --s
if
(0
------ ------
J1. —A
J
STUCCO
T UPPER LEVEL
I E
r
II
All
I
IC
1
i ,,i
I
MR
F
g
T UPPER LEVEL
I E
r
L
r
Y
7—
V, J- �- _—
-------- -- =41 F
GRADE
-TEX15TING
,/ LL � ^ lam — --°'fir--_.____.._ � � ti� t!_- - - - .��' __..__...».._.._ — °SFr _,�_._..- .�._— _;. -- ._�.._.__.._.
•
-TONE—,�
FIN15H GRADE
T
ENTRY LEVEL
-- -- -- ----
a014
CZ,
F7
A
1k.,
�7
..... -
-- - --- I! EXISTINC
L -
GAS METER EX15TING GRADE AT ELEC. METER,
LOCATION FACE OF BUILDING FAINT TO MATCH
ADJACENT WALL
FINISH GRADE
NOFRTH ELEVATION,
SCALE: 1/4" = ]'-O'l
ENTRY LEVEL
80g -0
LOWER
00al I - 0 ITNV
@2010 SMA
Segerberg Mayhew
& Associates Architects
P.C.-A.I.A.
ARCHITECTURE,
PLANNING, INTERIORS
101 Eagle Road - Building 6
Avon, CO 81620
Tel: 970.476.4433
Fax: 970.47
info@smarchs.com
www.smarchs.com
Revisions:
06-14-10 DR5 5UE3MITTAL
0(o-30-10 DR5 COMMENT5
Drawing Title:
BUILDING ELEVATIONS
[Date: 0(o-14-1
Project o: 3300(0 00
Drawn by: 6MK
=Checked by: 105
Sheet:
-1, 7- )r
All
L
r
Y
7—
V, J- �- _—
-------- -- =41 F
GRADE
-TEX15TING
,/ LL � ^ lam — --°'fir--_.____.._ � � ti� t!_- - - - .��' __..__...».._.._ — °SFr _,�_._..- .�._— _;. -- ._�.._.__.._.
•
-TONE—,�
FIN15H GRADE
T
ENTRY LEVEL
-- -- -- ----
a014
CZ,
F7
A
1k.,
�7
..... -
-- - --- I! EXISTINC
L -
GAS METER EX15TING GRADE AT ELEC. METER,
LOCATION FACE OF BUILDING FAINT TO MATCH
ADJACENT WALL
FINISH GRADE
NOFRTH ELEVATION,
SCALE: 1/4" = ]'-O'l
ENTRY LEVEL
80g -0
LOWER
00al I - 0 ITNV
@2010 SMA
Segerberg Mayhew
& Associates Architects
P.C.-A.I.A.
ARCHITECTURE,
PLANNING, INTERIORS
101 Eagle Road - Building 6
Avon, CO 81620
Tel: 970.476.4433
Fax: 970.47
info@smarchs.com
www.smarchs.com
Revisions:
06-14-10 DR5 5UE3MITTAL
0(o-30-10 DR5 COMMENT5
Drawing Title:
BUILDING ELEVATIONS
[Date: 0(o-14-1
Project o: 3300(0 00
Drawn by: 6MK
=Checked by: 105
Sheet:
I
MR
g
r
N
L
r
Y
7—
V, J- �- _—
-------- -- =41 F
GRADE
-TEX15TING
,/ LL � ^ lam — --°'fir--_.____.._ � � ti� t!_- - - - .��' __..__...».._.._ — °SFr _,�_._..- .�._— _;. -- ._�.._.__.._.
•
-TONE—,�
FIN15H GRADE
T
ENTRY LEVEL
-- -- -- ----
a014
CZ,
F7
A
1k.,
�7
..... -
-- - --- I! EXISTINC
L -
GAS METER EX15TING GRADE AT ELEC. METER,
LOCATION FACE OF BUILDING FAINT TO MATCH
ADJACENT WALL
FINISH GRADE
NOFRTH ELEVATION,
SCALE: 1/4" = ]'-O'l
ENTRY LEVEL
80g -0
LOWER
00al I - 0 ITNV
@2010 SMA
Segerberg Mayhew
& Associates Architects
P.C.-A.I.A.
ARCHITECTURE,
PLANNING, INTERIORS
101 Eagle Road - Building 6
Avon, CO 81620
Tel: 970.476.4433
Fax: 970.47
info@smarchs.com
www.smarchs.com
Revisions:
06-14-10 DR5 5UE3MITTAL
0(o-30-10 DR5 COMMENT5
Drawing Title:
BUILDING ELEVATIONS
[Date: 0(o-14-1
Project o: 3300(0 00
Drawn by: 6MK
=Checked by: 105
Sheet:
I
0 -7
rj
SCALE: 1/4" = 1'-0"
r 6 T.O. CHIMNEY 12
&ECTICN THfRCUGH 5ECCNE)AfR`� LIVINCam
SCALE: 1/4" = I'-0
EA&T ELEVATION
5G1 LE. 1/4" = I'-0
'Se Mayhew
• Associates Architects
P.C.-A.I.A.
-0 m m_ - OWN = - - = �
IMANOWIN 101991
101 Eagle Road - Building 6
Avon, CO 81620
Tel: 970.476.4433
Fax: 970.476.4608
info@smarcbs.com
www.smarchs.com
Revisions: I
06-14-10 DRE3 5Uf3M1TTAL
06-30-10 DR5 COMMENT5;
Drawing Title:
BUILDING ELEVATIONS
Checked by: _1<_51
Drawn by: FMK
Ro
L
01
k
9
A
\ J/
LEVEL e-F.
51TE COVERAGE CALCULATION:
LOT AREA = 21,028 5F.
25% MAX. = 5,251 S.F.
PROPOSED TOTAL = 4,814 5F.
ani I A =t= t7=/ A rl-= /,"- A I I I I A T I �N 1.
ut MAX, = lzro 15.f . roV14V = 4�rok212yVl
LOWER LEVEL:
PRIMARY 1e84 S.F. x .10 = 1388 5F.
5ECONDARY 1e42 S.F. x .10 = 135 5F.
ENTRY LEVEL:
PRIMARY 2555 5F,
UPPER LEVEL:
FIRIMARY 1091 5F.
5ECONIDARY 20615.F.
PRIMARY TOTAL = 5040 S.F.
- 600 S.F. (Garage Credit)
PRIMARY TOTAL = 4440 5F.
SECONDARY' TOTAL = 3420 S.F.
600 5F. (Garage Credit)
5ECONE)ARY TOTAL = 2820 5F.
PRIMARY + SECONDARY' TOTAL = 1260 S.F.
51TE COVEfRAGE CALCULATION
T
� , �� i S f � 1 4 4 ; !
ENTfR`' LEVEL F.
1i
U�
G
V%
.11
�
0 0 0
100 100 im 10.6/15 .10
@2010 SMA
"7 I TJL"j
♦ Associates Architects
P.C.-A.I.A.
ARCHITECTURE,
PLANNING, INTERIORS
101 Eagle Road - Building 6
Avon, CO 81620
Tel: 970.476.4433
Fax: 970.476.4608
info@smarchs.com
www.smarchs.com
Revisions:
6-14-10 DRE3 5UBMITTAL
6-30-10 DR5 COMMENT5
Drawing Title:
SQUARE FOOTAGE AND
SITE COVERAGE
CALCULATIONS
Sheet:
0 00