Loading...
HomeMy WebLinkAboutF11-0034TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970 - 479 -2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Permit #: F11 -0034 Job Address: 100 E MEADOW DR VAIL Status ...: ISSUED Location.....: VAIL VILLAGE INN PLAZA CONDOS UNIT 305 Applied..: 06/22/2011 Parcel No...: 210108261015 Issued . .: 07/06/2011 Project No Expires. .: $717.12 OWNER GABRIEL, PATRICIA ANN 06/22/2011 $0.00 1 E RIDGEWOOD AVE $717.12 PARAMUS BALANCE DUE --------- > NJ 07653 ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** APPLICANT WESTERN STATES FIRE PROTECTI 06/22/2011 Phone: 303 - 792 -0022 7026 S TUCSON WAY Item: 05600 FIRE DEPARTMENT CENTENNIAL CO 80112 mvaughan Action: AP Spacing of License: 0000003191 shall be in com with CONTRACTOR WESTERN STATES FIRE PROTECTI 06/22/2011 Phone: 303 - 792 -0022 7026 S TUCSON WAY CENTENNIAL CO 80112 License: C000003191 Desciption: RELOCATE 16 HEADS, PLUG 2, ADD 2. NO CHANGE IN HEAD COUNT. Valuation: $6,708.80 ************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** FEE SUMMARY ************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Mechanical --- > $0.00 Restuarant Plan Review - -> $0.00 Total Calculated Fees --- > $717.12 Plan Check --- > $432.00 DRB Fee --------------------- > $0.00 Additional Fees------ - - - - -> $0.00 Investigation -> $0.00 TOTAL FEES--------- - - - - -> $717.12 Total Permit Fee ---------- > $717.12 Will Call - - - - -> $0.00 Payments ------------------- > $717.12 BALANCE DUE --------- > $0.00 ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 07/01/2011 mvaughan Action: AP Spacing of sprinkler heads shall be in com with listing on cut sheets. Approval subject to field inspections. CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 53 (FIRE 2007) Monitored fire sprinkler system required and shall comply with NFPA 13 (2007) and VFES Standards. ************************************************************************************************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970 - 479 -2252 FROM 8:00 AM - 5 PM. SIGNATURE Of OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF Copy Reprinted on 01 -04 -2013 at 11:37:20 RECEIPT NUMBER: R110000738 SET ID: S000000364 SET RECEIPT 01/04/2013 SET NAME: Temporary Set TRANSACTION DATE: 07/06/2011 TOTAL PAYMENT: 1,285.76 TOTAL PAID FROM TRUST: .00 TOTAL PAID FROM CURRENCY: 1,285.76 SET TRANSACTIONS: Set Member Amount ---- - - - - -- ------ - - - - -- Fll -0034 717.12 Fll -0036 568.64 TOTAL: 717.12 TRANSACTION LIST: Type Method Description Amount ---- - - - - -- -- - - - - -- --------------------- - - - - -- ------ - - - - -- Payment Check 120963 1,285.76 TOTAL: 1,285.76 ACCOUNT ITEM LIST: Description Account Code Current Pmts ------------------------ - - - - -- ---------- - - - - -- ------ - - - - -- PLAN CHECK FEES PF 0010000311230 864.00 SPRINKLER PERMIT FEES BP 0010000311110 421.76 TOTAL: 1,285.76 RECEIPT ISSUED BY: LCAMPBELL INITIALS: LC ENTERED DATE: 07/06/2011 TIME: 08:46 AM FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: Office Use: `bb C 1y\e6,kA, 5 Project #: C S I - ODq (Number) (Street) (Suite #) Building Permit #: BuildinglComplex Name: `A Q Jv\A Sprinkler Permit #: Contractor Information: rt Lot M Block # Subdivision: Company: JAk S �vut S F-1 Tvb}ec.�'1o�1 . Company Address: 16x6 S,Tuc %y� t & Detailed Description of Work: tZe`D(Ak t� City: ( idvll State: Zip: Q _ ilAo„ {��� — a . �o LEA Contact Name: �oc��a t C� l� kewu bq,&k (use additional sheet If necessary Contact Phone: h7 O) ak 6 - 7 - 3 A r _ _ E -Mail ICo& C� wS'pp . US Detailed Location of Work: 1A\A �- Town of Vail Contractor Registratlon No.: Contractor Sign atur - eJr qutr y Property Information _ i Parcel M aw I OnV odd j (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us/patie) i Tenant Name: 0_4.x\ �� Ul c' �� t i Owner Name: s�sr�t — v.T7 J �a .�_+�c" . OT US 1�EA1I l Complete Valuation for Fire Sprinkler Permit: Q CQAaY� . Fire Sprinkler $: 0 Does a Monitored Fire Alarm Exist? Yes ( t'rNo ( ) Does a Sprinkler System Exist? Yes (� { ) Work Class: New ( ) Addition ( ) Remodel ( -Repair ( ) Retro -Fit ( ) Other ( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family Commercial ( ) Restaurant () Other ( ) Date Received: JUN 2 0 2011 TOWN OF VAIL 01- Feb-10 el Model F1 FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model F1 FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters' Laboratories of Canada (ULC) 3. Certified by FM Approvals 4. Loss Prevention Council (LPC, UK) 5. NYC BS&A No. 587 -75 -SA 6. Meets MIL- S -901C and MIL -STD 167 -1 7. Verband der Schadenversicherer (VdS, Germany) 8. NYC MEA 258 -93 -E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV Patents: US Patent No. 6,374,920 Applies to Model F1FR Vertical Sidewall Sprinklers. Product Description Reliable Models F1 FR and F1 FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1 FR and F1 FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR and F1 FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- Bulletin 136 Rev.O Model F1 FR Model F1 FR Recessed Quick Response Sprinklers �f O . Upright �ir i i Pendent Vertical Sidewall Conventional �- 11 Horizontal Sidewall Recessed Pendent HSW 1 Deflector (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2 -8N or other applicable standards. Quick response sprinklers and standard response sprinklers should not be intermixed. W 1 w Lel The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523 Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: 10mm Orifice XLH with W Thread 1 4.2 1 60 1 56mm 83674 1 15mm Standard Orifice with Y," NPT RY Thread 5.6 80 56mm 4,6,7 83675 20mm Lar a Orifice with 3 /4 ' NPT (R /,)Thread 8.0 115 58mm 4,7 83672 f) t Polyester coated upriqht UL and ULC listed corrosion resistant. n I c� Upright Pendent Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor i Sprinkler Identification Sprinkler Type Metric y" (15mm) Sprinkler Approval Number (SIN) 2.2" (56mm) 1,2,3,4,5,7,8 US Metric _ Height Organization - SSU __ Standard -U ri ht (SSU and Pendent (SSP) Deflectors 5.6 80 8.0 115 Marked to Indicate 2.2" 56mm 2.3" 58mm Position 1,2,3,4,5,6,7 1,2,3,4,7,8 R3625 R3622 R3615 R3612 15mm Standard Orifice with " NPT (Ry ) Thread 20mm Large Orifice with 3 '" NPT R /A Thread 1,2,8 4.2 2.8 60 40 2.2 56mm 2.2" (56mm) 1,2,8 1,2,8 R3623t R3621 R3613 R3611 "(17mm ) Smal I Orifice with "NPT Ry)Thread (10mm ) Small Orifice with "NPT Ry)Thread 10mm Orifice XLH with R Thread Rte 4.2 60 56mm 4,6,7 R3624 R3614 Conventional- Install in Upright or Pendent Position 10mm Orifice XLH with W Thread 1 4.2 1 60 1 56mm 83674 1 15mm Standard Orifice with Y," NPT RY Thread 5.6 80 56mm 4,6,7 83675 20mm Lar a Orifice with 3 /4 ' NPT (R /,)Thread 8.0 115 58mm 4,7 83672 f) t Polyester coated upriqht UL and ULC listed corrosion resistant. n I c� Upright Pendent Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Approvalt' Sprinkler Identification Organizations Number (SIN) Us Metric y" (15mm) Y NPT (R 5.6 80 2.2" (56mm) 1,2,3,4,5,7,8 R3615 '% " (20mm) gY NPT (R 8.0 115 2.3" (58m 1,2,3,8 R3612 %B' (11 mm) }z" NPT (RY2) 4.2 60 2.2" (56mm) — 1,2,8 R3613 Y'" (10mm) }/ NPT (R' /2) 2.8 40 2.2" (56mm) 1,2,8 R3611 10mm Rte 4.2 60 56mm t 4,7 83614 t' Refer to escutcheon data table for approvals and dimensions. 1 114' HOLE VIA. (57.2mm] 1 15116" DA (49.2 -1 1' X 111' REDVCER lL'RN COLLAR VNlIL FICHT AGAINST SPRINKLER NRENGI 8055 FACE OF ADJUSTMENT (I) 00 VN 1 CEILI fJ.1mm] 2 17132" VA. [72.2mm] IJ6FG07_E (1) REFER TO F1 h F2 ESCUTCHEON VAT, TABLE FOR APPROVALS AND DIMENSIONS. "( CEILING f- 2 518 DIA. (66.7m 1 HOLE IN CEILING 2 5116" DIA. [58.7mm] CUP 1 I L J- Convent I X 112° REDUCER VJDVC FACE OF FITTING C - -- - TO FACE OF CEILING \\ DIMENS/ON (/} 11 A' (I) 4DJUSTM£NT -- -- -- (1) REFER FO FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. Model F1 FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Thread K Factor Sprinkler Approval Sprinkler US Metric Orifice Size Height Organizations Identification Number (SIN) Y2" 1 /2" NPT (R /2) 5.6 80 2.2" (56mm) 1, 2, 3, 6, 8 [31.8mm) 2 114" HOLE DIA. [57.2mmJ R3685 15mm Yi' NPT (R' /2) 5.6 80 2.2" (56mm) 4 (1) DEFLECTOR 171 LPC Approval is for Pendent position only. tis d if Vertical Sidewall US Patent No. 6,374,920 Orientation Deflector to Ceiling Dimension (Min. - M Up right 4" - 12" 102mm - 305mm _ Pendent 6" - 12" 152mm - 305mm Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations K Factor and Type of Approval Nominal Thread Sprinkler Light Ordinary Orifice Size US Metric Length Hazard Hazard Y (15mm) I y" NPT(R'/2) 1 5.6 1 80 I 2.63" (67mm) I 1,2,3,5,8 1,2,5,8 NOTE: UL, ULC and MEA Listing permits use with F1 or F2 recessed escutcheon. -1 Horizontal Sidewall Sprinkler Identification Number (SIN) R 3635 736FG04 (1) FACE f!J OF FITTING TO WALL DIMENSION 1 1/4" MIN. [31.8mm) 2 114" HOLE DIA. [57.2mmJ [3.2mm) [101.6mm- 152.4mm] CEILING TO 1 " X 1/2" REDUCER DEFLECTOR 1 15116" DIA. l inii - -- 49.2mm [ ) 2 27132" DIA. liltl I [72.2mm] TURN COLLAR UNTIL TIGHT SPRINKLER `� t WRENCH�BOSS. `\ ADJUSTMENT (1) REFER TO ESCUTHCEON DATA TABLE FOR APPROVALS AND DIMENSIONS. 3. Installation Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2 -8N or other applicable standards. Quick response sprin- klers and standard response sprinklers should not be inter- mixed. The Model F1 FR Recessed Quick Response Sprinklers are to be installed as shown. The Model F1 or F2 Escutcheons illus- trated are the only recessed escutcheons to be used with the Model F1 FR Sprinklers. The use of any other recessed escutch- eon Will void all approvals and negate all warranties. When installing Model F1 FR Sprinklers, use the Model D Sprin- kler Wrench. When installing Model F1 FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratin Classification Sprinkler Tempe rature Max. Ambient Temp. Bulb Color °C "F Ordinary 57 135 100 Orange Ordinary 68 155 100 F(38°C) Red Intermediate 79 175 150-F (66-C) Yellow Intermediate 93 200 150-F (66-C) Green High (t) 141 286 225 °F(107 °C) Blue (t) Not available for recessed sprinklers. Escutcheon Data Esculdlieorti S rinkler Escutcheon Bronze Face of Filing Model Approtials White Polyester Coated (4) Dimension to Ceiling or Sprinkler Escutcheon Bright Brass Bright Brass Wall Dirttension Black Plated Black Paint Black Paint 1 / Off White F1 1,2,4,8 Max Recess (38.1 mm) %6 " - %6 Min Recess %" (5mm -24mm) 19.1 mm 1y" F2 1,2,3,4,5,7,8 Max Recess (38.1 mm) �/ 716 Min Recess 6 ,6 (5mm -17mm) 24mm FP 1,2 Max Recessed �6 1y "(38.1mm) 11 mm Push-on/ Thread -off 1,2 Min Recessed /16 1" (25.4mm) ( 2 mm No Dimensional Figure for FP Maintenance The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non - operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes " 121 Standard Finishes S rinkler Escutcheon Bronze Brass Chrome Plated Chrome Plated (3) White Polyester Coated (4) White Painted (3) Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome (t) Other finishes and colors are available on special order. Consult the factory for details. ( FM Approvals is limited to bronze and brass, chrome or black plated finishes only. ( FP Push- on/Thread -off escutcheon. ( UL and ULC listed corrosion resistance. SIN numbers: R3621, R3622, R3623, R3625. Note: For }2" orifice pendent FM approved white polyester coated and UL approved white polyester corrosion resistant sprinklers refer to Bulletin 014. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) Note: When Model F1FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputa- ble sprinkler contractors located throuahout the United States. Canada and foreian countries. Manufactured by fleliabld The Reliable Automatic Sprinkler Co., Inc. (800)431 -1588 Sales Offices (800)848 -6051 Sales Fax (914)829 -2042 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision lines indicate updated or new data EG. Printed in U.S.A. 3/07 P/N9999970027 Wheatland's Schedule 40 Sprinkler Pipe Wheatland's Schedule 40 Sprinkler Pipe is a high quality sprinkler pipe offering you the full range of assurances you require. Schedule 40 Sprinkler Pipe has passed some of the toughest lab tests ever created for sprinkler pipe. Made in the U.S.A. by Wheatland Tube Company means made to the highest standards for consistant quality. Specifications and Approvals Wheatland's schedule 40 Sprinkler Pipe is made from the highest quality steel in one of the nation's most modern and most complete pipe manufacturing plants. Our proprietary mill coating offers you a clean, corrosion and heat resistant surface that outlasts and outperforms standard lacquer coatings. Plus, this coating can be quickly and easily painted without special preparation. Or it may be hot - dipped galvanized to meet FM requirements for dry systems in accordance with the zinc coating specification of ASTM A795. Schedule 40 is also available as ASTM A 53 Type F, Grade A in NPS 1 - 6 and is UL Listed and FM Approved. Wheatland's Schedule 40 Standard Wall Sprinkler Pipe meets or exceeds the following: • UL Listed • FM Approved • ASTM A795, Type E, Grade A Please refer to appropriate documentation for up -to -date listing and approval information. Specifications and descriptions are accurate as known at time of publication and are subject to change without notice. Specifications NPS Nominal O.D Nominal I.D Nominal Wall Nominal Weight UL CRR' Pieces Lift in. mm in. mm in. mm lbs. /ft. kg /m 1 " 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 1 1/4" 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 1 1/2" 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2" 1 2.375 1 60.3 1 2.067 1 52.5 .154 3.91 3.66 1 5.45 1.00 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Schedule 40 steel pipe is used as the benchmark (value of 1.0). Wheatland Tube Company Council Avenue, P.O. Box 608 Wheatland, PA 16161 -0608 Ph 800.257.8182 Fax 724.346.7260 www.wheatiand.com 0207 1.Wrev01