HomeMy WebLinkAbout10-039 20100921 Retaining Wall Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy YSuite 115 YLakewood, CO 80228-2845 , www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970)241-7700 (303) 989-0204 FAX (970) 241-7783 FAX Tom Kassmel, P.E. Job No. 10-039 Town of Vail, Department of Public Works/Transportation Set No. 2 1309 Elkhorn Drive Vail, CO 81657 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado Location: Retaining Wall, Sampled at Gridlines E.0-D.4 Total Cubic Yards: 10 Supplier: Lafarge Ticket No: 85909131 Mix Design No: RMXCE45DG8V Slump: 4.75 inch(es) Air Content: 7.0 % Wet Unit Weight: 139.9 pcf Concrete Temperature 60 °F Air Temperature: 65 °F Test Date: 09/21/10 Time Test Taken: 9:15 AM Design Strength: 4000 psi at 28 days Amount of Water Added at Site: 0 gallons Remarks: *Refer to ASTM C39/C39M-OS Age (days) Total Load (lbs) Diameter(in.) Area (sq. in.) Compressive Strength(psi) Type of Fracture* 7 55700 4.01 12.63 4410 5