HomeMy WebLinkAbout10-039 20101010 Bridge Beam - Revised 10-22-10 Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy YSuite 115 YLakewood, CO 80228-2845 , www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970)241-7700 (303) 989-0204 FAX (970) 241-7783 FAX Tom Kassmel, P.E. Job No. 10-039 Town of Vail, Department of Public Works/Transportation Set No. 13 1309 Elkhorn Drive Vail, CO 81657 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado Location: Drive-in/Drive-out Bridge Beam, Sampled at Gridlines E-E.2 to E-E.5/E-1 Total Cubic Yards: 9 Supplier: Lafarge Ticket No: 0016861 Mix Design No: RMXCE45DG8V Slump: 5.75 inch(es) Air Content: 5.1 % Wet Unit Weight: 142.4 pcf Concrete Temperature 64 °F Air Temperature: 58 °F Test Date: 10/10/10 Time Test Taken: 1:23 PM Design Strength: 5000 psi at 28 days Amount of Water Added at Site: 5 gallons Remarks: *Refer to ASTM C39/C39M-OS Age (days) Total Load (lbs) Diameter(in.) Area (sq. in.) Compressive Strength(psi) Type of Fracture* 3 40870 4.00 12.57 3250 2 7 55304 4.00 12.57 4400 5