Loading...
HomeMy WebLinkAbout10-039 20101015 Structural Salb Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy YSuite 115 YLakewood, CO 80228-2845 , www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970)241-7700 (303) 989-0204 FAX (970) 241-7783 FAX Tom Kassmel, P.E. Job No. 10-039 Town of Vail, Department of Public Works/Transportation Set No. 15 1309 Elkhorn Drive Vail, CO 81657 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado Location: Structural Slab for Drive-in/Drive-out, Sampled at Gridlines E-1 Total Cubic Yards: 6.5 Supplier: Lafarge Ticket No: 85909315 Mix Design No: RMXCE45DG8V Slump: 4.00 inch(es) Air Content: 7.0 % Wet Unit Weight: 139.8 pcf Concrete Temperature 65 °F Air Temperature: 50 °F Test Date: ]0/]5/]0 Time Test Taken: 8:20 AM Design Strength: 5000 psi at 28 days Amount of Water Added at Site: 0 gallons Remarks: *Refer to ASTM C39/C39M-OS Age (days) Total Load(lbs) Diameter(in.) Area(sq. in.) Compressive Stren�th (psi) Type of Fracture* 7 55290 4.01 12.63 4380 5 7 58132 4.01 12.63 4600 Average: 4490 2 28 64522 4.01 12.63 S ll 0 5 28 71604 4.01 12.63 5670 4 28 710ll 4.01 12.63 5620 Average: 5470 4