Loading...
HomeMy WebLinkAbout10-039 20101022 Retaining Wall Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy YSuite 115 YLakewood, CO 80228-2845 , www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970)241-7700 (303) 989-0204 FAX (970) 241-7783 FAX Tom Kassmel, P.E. Job No. 10-039 Town of Vail, Department of Public Works/Transportation Set No. 17 1309 Elkhorn Drive Vail, CO 81657 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado Location: Retaining Wall at West End of Parking Structure, Sampled at Gridlines E-B.3/E-1 Total Cubic Yards: 10 Supplier: Lafarge Ticket No: 85909422 Mix Design No: RMXCE45DG8V Slump: 5.25 inch(es) Air Content: 6.5 % Wet Unit Weight: 139.8 pcf Concrete Temperature 57 °F Air Temperature: 50 °F Test Date: ]0/22/]0 Time Test Taken: 1:50 PM Design Strength: 5000 psi at 28 days Amount of Water Added at Site: 5 gallons Remarks: *Refer to ASTM C39/C39M-OS Age (days) Total Load(lbs) Diameter(in.) Area(sq. in.) Compressive Stren�th (psi) Type of Fracture* 7 59432 4.01 12.63 4710 2 28 74955 4.01 12.63 5930 2 28 74220 4.01 12.63 5880 Average: 5910 5