HomeMy WebLinkAbout10-039 20101103 Curb Gutter Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy YSuite 110 YLakewood, CO 80228-2845 , www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970)241-7700 (303)989-0204 FAX (970)241-7783 FAX Tom Kassmel, P.E. Job No. 10-039 Town of Vail, Department of Public Works/Transportation Set No. 23 1309 Elkhorn Drive Vail, CO 81657 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado Location: Curb and Gutter, Sainpled 60' East of Northwest Corner of South Drive-in/Drive-out Wall Total Cubic Yards: 10 Supplier: Lafarge Ticket No: 85909493 Mix Design No: RMXDG45GD87 Slump: 3.25 inch(es) Air Content: 6.0 % Wet Unit Weight: 141.3 pcf Concrete Temperature 72 °F Air Temperature: 55 °F Test Date: 11/03/]0 Time Test Taken: 11:50 AM Design Strength: 5000 psi at 28 days Amount of Water Added at Site: 5 gallons Remarks: Concrete did not meet average compressive strength at 28 days, but did make the required strength at 56 days. *Refer to ASTM C39/C39M-OS A e da s Total Load(lbs) Diameter(in.) Area(sq. in.) Compressive Stren�th (psi) Type of Fracture* 7 47062 4.01 12.63 3730 3 28 58117 4.01 12.63 4600 3 28 60408 4.01 12.63 4780 Average: 4690 3 56 71887 4.02 12.69 5660 2