Loading...
HomeMy WebLinkAbout10-039 20101117 Retaining Wall Cap Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy YSuite 115 YLakewood, CO 80228-2845 , www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970)241-7700 (303) 989-0204 FAX (970) 241-7783 FAX Tom Kassmel, P.E. Job No. 10-039 Town of Vail, Department of Public Works/Transportation Set No. 33 1309 Elkhorn Drive Vail, CO 81657 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado Location: North Cantilever Retaining Wall Cap for the Southwest Parking Entrance Total Cubic Yards: 6.5 Supplier: Lafarge Ticket No: 85909580 Mix Design No: RMXCE45DG8V Slump: 3.50 inch(es) Air Content: 7.0 % Wet Unit Weight: 140.6 pcf Concrete Temperature 56 °F Air Temperature: 40 °F Test Date: 1]/]7/]0 Time Test Taken: 11:33 AM Design Strength: 5000 psi at 28 days Amount of Water Added at Site: 0 gallons Remarks: *Refer to ASTM C39/C39M-OS Age (days) Total Load(lbs) Diameter(in.) Area(sq. in.) Compressive Stren�th (psi) Type of Fracture* 7 49268 4.01 12.63 3900 2 28 67688 4.01 12.63 5360 2 28 66699 4.01 12.63 5280 Average: 5320 2