Loading...
HomeMy WebLinkAbout10-039 20101118 Foundation Walls - Sets 34 to 36 Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy YSuite 115 YLakewood, CO 80228-2845 , www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970)241-7700 (303) 989-0204 FAX (970) 241-7783 FAX Tom Kassmel, P.E. Job No. 10-039 Town of Vail, Department of Public Works/Transportation Set No. 34 1309 Elkhorn Drive Vail, CO 81657 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado Location: ECO Building Foundation Walls, Sampled at Gridlines C.0/4.5-8.0, lst Lift Total Cubic Yards: 29.25 Supplier: Lafarge Ticket No: 85909590 Mix Design No: RMXCE40GD87 Slump: 3.00 inch(es) Air Content: 3.5 % Wet Unit Weight: 145.9 pcf Concrete Temperature 66 °F Air Temperature: 36 °F Test Date: 1]/]8/]0 Time Test Taken: 12:02 PM Design Strength: 4000 psi at 28 days Amount of Water Added at Site: 0 gallons Remarks: *Refer to ASTM C39/C39M-OS Age (days) Total Load(lbs) Diameter(in.) Area(sq. in.) Compressive Stren�th (psi) Type of Fracture* 7 51077 4.01 12.63 4040 2 28 58429 4.01 12.63 4630 5 28 58966 4.01 12.63 4670 5 28 60945 4.02 12.69 4800 Average: 4700 2 Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy YSuite 115 YLakewood, CO 80228-2845 , www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970)241-7700 (303) 989-0204 FAX (970) 241-7783 FAX Tom Kassmel, P.E. Job No. 10-039 Town of Vail, Department of Public Works/Transportation Set No. 35 1309 Elkhorn Drive Vail, CO 81657 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado Location: ECO Building Foundation Walls, Sampled at Gridlines A.0-C.0/8.0 and A.0/6.1-8.0, 3rd Lift Total Cubic Yards: 107 Supplier: Lafarge Ticket No: 85909601 Mix Design No: RMXCE40GD87 Slump: 3.50 inch(es) Air Content: 4.5 % Wet Unit Weight: 143.8 pcf Concrete Temperature 64 °F Air Temperature: 39 °F Test Date: 1]/]8/]0 Time Test Taken: 2:51 PM Design Strength: 4000 psi at 28 days Amount of Water Added at Site: 0 gallons Remarks: *Refer to ASTM C39/C39M-OS Age (days) Total Load(lbs) Diameter(in.) Area(sq. in.) Compressive Stren�th (psi) Type of Fracture* 7 51303 4.02 12.69 4040 2 28 52420 4.01 12.63 4150 5 28 51374 4.01 12.63 4070 5 28 53184 4.01 12.63 42]0 Average: 4]40 5 Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy YSuite 115 YLakewood, CO 80228-2845 , www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970)241-7700 (303) 989-0204 FAX (970) 241-7783 FAX Tom Kassmel, P.E. Job No. 10-039 Town of Vail, Department of Public Works/Transportation Set No. 36 1309 Elkhorn Drive Vail, CO 81657 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado Location: ECO Building Foundation Walls, Sampled at Gridlines A.0-C.0/6.1, A.2/5.5-6.0, and A3-A.5/0.0, Top Lift Total Cubic Yards: 156.25 Supplier: Lafarge Ticket No: 85909608 Mix Design No: RMXCE40GD87 Slump: 5.25 inch(es) Air Content: 5.4 % Wet Unit Weight: 142.3 pcf Concrete Temperature 60 °F Air Temperature: 33 °F Test Date: 1]/]8/]0 Time Test Taken: 4:33 PM Design Strength: 4000 psi at 28 days Amount of Water Added at Site: 0 gallons Remarks: *Refer to ASTM C39/C39M-OS Age (days) Total Load(lbs) Diameter(in.) Area(sq. in.) Compressive Stren�th (psi) Type of Fracture* 7 42835 4.01 12.63 3390 5 28 5659] 4.01 12.63 4480 5 28 57015 4.01 12.63 4510 2 28 52887 4.01 12.63 4190 Average: 4390 3