HomeMy WebLinkAbout10-039 20101129 Footing Koechlein Consulting Engineers, Inc.
Consulting Geotechnical Engineers
12364 W. Alameda Pkwy YSuite 110 YLakewood, CO 80228-2845
, www.KCE-Denver.com
LAKEWOOD GRAND JUNCTION
(303) 989-1223 (970)241-7700
(303)989-0204 FAX (970)241-7783 FAX
Tom Kassmel, P.E. Job No. 10-039
Town of Vail, Department of Public Works/Transportation Set No. 39
1309 Elkhorn Drive
Vail, CO 81657
SUMMARY OF CONCRETE TEST RESULTS
Project: Lionshead Transit Center, Vail, Colorado
Location: Footing, Sampled at Gridlines E-E.1/55' West of E-1
Total Cubic Yards: 10
Supplier: Lafarge Ticket No: 85909633 Mix Design No: RMXCE40GD87
Slump: 4.50 inch(es) Air Content: 5.5 % Wet Unit Weight: 142.8 pcf
Concrete Temperature 68 °F Air Temperature: 30 °F
Test Date: 1]/29/]0 Time Test Taken: 3:25 PM
Design Strength: 4000 psi at 28 days Amount of Water Added at Site: 0 gallons
Remarks:
*Refer to ASTM C39/C39M-OS
Age (days) Total Load(lbs) Diameter(in.) Area(sq. in.) Compressive Stren�th (psi) Type of Fracture*
7 41252 4.01 12.63 3270 3
28 61821 4.00 12.57 4920 2
28 56209 4.01 12.63 4450 2
28 63320 3.99 12.50 5070 Average: 4810 2