HomeMy WebLinkAbout10-039 20101222 Grade Beam Koechlein Consulting Engineers, Inc.
Consulting Geotechnical Engineers
12364 W. Alameda Pkwy• Suite 110• Lakewood, CO 8022&2845
� www.KCE-Denver.com
LAKEWOOD GRAND JUNCTION
(303) 989-1223 (970)241-7700
(303) 989-0204 FAX (970)241-7783 FAX
Tom Kassmel,P.E. Job No. ]0-039
Town of Vail, Department of Public Works/Transportation Set No. 50
1309 Elkhorn Drive
Vail, CO 81657
SUMMARY OF CONCRETE TEST RESULTS
Project: Lionshead Transit Center, Vail, Colorado
Location: ECO Building Grade Beam, Sampled at Gridlines A.0/1.1
Total Cubic Yards: 9
Supplier: Lafarge Ticket No: 85822849 Mix Design No: RMXCE45DG8V
Slump: 6.00 inch(es) Air Content: 4.5 % Wet Unit Weight: 142.3 pcf
Concrete Temperature: 60 °F Air Temperature: 40 °F
Test Date: 12/22/10 Time Test Taken: 2:50 PM
Design Strength: 5000 psi at 28 days Amount of Water Added at Site: 0 gallons
Remarks:
*Refer to ASTM C39/C39M-OS
A e da s Total Load(lbs� Diameter(in.� Area(�. in.� Compressive Stren_t� h(�si� Tyt�e of Fracture*
7 69031 4.01 12.63 5470 2
28 89149 4.01 12.63 7060 5
28 92174 4.00 12.57 7330 3
28 9165] 4.01 12.63 7260 Average: 7220 3