Loading...
HomeMy WebLinkAbout10-039 20101229 Planter Box Walls and Slab Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy YSuite 110 YLakewood, CO 80228-2845 , www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970)241-7700 (303)989-0204 FAX (970)241-7783 FAX Tom Kassmel, P.E. Job No. 10-039 Town of Vail, Department of Public Works/Transportation Set No. 53 1309 Elkhorn Drive Vail, CO 81657 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado Location: Planter Box Walls along Gridlines A.0-A.6/3.0, A.6/3.0-3.3, A.0/3.0, A.0/3.0-4.0, and A.0/4.0, and Slab along A.0/6.1-8.0 Total Cubic Yards: 6.5 Supplier: Lafarge Ticket No: 85822872 Mix Design No: RMXCE45DG8V Slump: 6.25 inch(es) Air Content: 8.4 % Wet Unit Weight: 137.7 pcf Concrete Temperature 68 °F Air Temperature: 32 °F Test Date: 12/29/]0 Time Test Taken: 3:50 PM Design Strength: 5000 psi at 28 days Amount of Water Added at Site: 6 gallons Remarks: *Refer to ASTM C39/C39M-OS Age (days) Total Load(lbs) Diameter(in.) Area(sq. in.) Compressive Stren�th (psi) Type of Fracture* 7 47444 4.00 12.57 3770 2