HomeMy WebLinkAbout10-039 20101229 Planter Box Walls Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy• Suite 110• Lakewood, CO 8022&2845 � www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970)241-7700 (303) 989-0204 FAX (970)241-7783 FAX Tom Kassmel,P.E. Job No. ]0-039 Town of Vail, Department of Public Works/Transportation Set No. 53 1309 Elkhorn Drive Vail, CO 81657 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado Location: Planter Box Walls along Gridlines A.0-A.6/3.0,A.6/3.0-3.3,A.0/3.0,A.0/3.0-4.0, and A.0/4.0, and Slab along A.0/6.1-8.0 Total Cubic Yards: 6.5 Supplier: Lafarge Ticket No: 85822872 Mix Design No: RMXCE45DG8V Slump: 6.25 inch(es) Air Content: 8.4 % Wet Unit Weight: 137.7 pcf Concrete Temperature: 68 °F Air Temperature: 32 °F Test Date: 12/29/10 Time Test Taken: 3:50 PM Design Strength: 5000 psi at 28 days Amount of Water Added at Site: 6 gallons Remarks: *Refer to ASTM C39/C39M-OS A e da s Total Load(lbs� Diameter(in.� Area(�. in.� Compressive Stren_t� h(�si� Tyt�e of Fracture* 7 47444 4.00 12.57 3770 2 28 69003 4.01 12.63 5460 3 28 69300 4.01 12.63 5490 3 28 71194 4.01 12.63 5640 Average: 5530 2