HomeMy WebLinkAbout10-039 20110105 Elevated Deck Koechlein Consulting Engineers, Inc. Consulting Geotechnical Engineers 12364 W. Alameda Pkwy YSuite 110 YLakewood, CO 80228-2845 , www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970)241-7700 (303)989-0204 FAX (970)241-7783 FAX Tom Kassmel, P.E. Job No. 10-039 Town of Vail, Department of Public Works/Transportation Set No. 55 1309 Elkhorn Drive Vail, CO 81657 SUMMARY OF CONCRETE TEST RESULTS Project: Lionshead Transit Center, Vail, Colorado Location: Elevated Deck, Sampled at Gridlines A.0-A.5/6.1-8.0 Total Cubic Yards: 18.5 Supplier: Lafarge Ticket No: 85822891 Mix Design No: RMXLTH45GD8V Slump: 3.75 inch(es) Air Content: 1.6 % Wet Unit Weight: 147.8 pcf Concrete Temperature 56 °F Air Temperature: 28 °F Test Date: O]/OS/]1 Time Test Taken: 11:12 AM Design Strength: 4000 psi at 28 days Amount of Water Added at Site: 8 gallons Remarks: *Refer to ASTM C39/C39M-OS Age (days) Total Load(lbs) Diameter(in.) Area(sq. in.) Compressive Stren�th (psi) Type of Fracture* 7 54230 4.01 12.63 4290 5 28 78659 4.01 12.63 6230 2 28 78150 4.01 12.63 6190 2 28 693]4 4.01 12.63 5490 Average: 5970 2