HomeMy WebLinkAbout10-039 20110105 Elevated Deck Koechlein Consulting Engineers, Inc.
Consulting Geotechnical Engineers
12364 W. Alameda Pkwy YSuite 110 YLakewood, CO 80228-2845
, www.KCE-Denver.com
LAKEWOOD GRAND JUNCTION
(303) 989-1223 (970)241-7700
(303)989-0204 FAX (970)241-7783 FAX
Tom Kassmel, P.E. Job No. 10-039
Town of Vail, Department of Public Works/Transportation Set No. 55
1309 Elkhorn Drive
Vail, CO 81657
SUMMARY OF CONCRETE TEST RESULTS
Project: Lionshead Transit Center, Vail, Colorado
Location: Elevated Deck, Sampled at Gridlines A.0-A.5/6.1-8.0
Total Cubic Yards: 18.5
Supplier: Lafarge Ticket No: 85822891 Mix Design No: RMXLTH45GD8V
Slump: 3.75 inch(es) Air Content: 1.6 % Wet Unit Weight: 147.8 pcf
Concrete Temperature 56 °F Air Temperature: 28 °F
Test Date: O]/OS/]1 Time Test Taken: 11:12 AM
Design Strength: 4000 psi at 28 days Amount of Water Added at Site: 8 gallons
Remarks:
*Refer to ASTM C39/C39M-OS
Age (days) Total Load(lbs) Diameter(in.) Area(sq. in.) Compressive Stren�th (psi) Type of Fracture*
7 54230 4.01 12.63 4290 5
28 78659 4.01 12.63 6230 2
28 78150 4.01 12.63 6190 2
28 693]4 4.01 12.63 5490 Average: 5970 2