HomeMy WebLinkAbout10-039 20110503 Mortar Cubes KOECHLEIN CONSULTING ENGINEERS, INC.
Lakewood—(303)989-1223
Grand Junction—(970)241-7700
Report of Masonry Testing
To: Town of vail Job No. 10-039 Cast Date: 5/3/11
Tom Kassmel,P.E.
Town Engineer
Department of Public Works/Transportation Set N0. 57 Sheet: 1 Of 1
1309 Elkhorn Drive
Vail,Colorado 81657
Project: Lionshead Transit Center,Vail, Colorado
Test Location: Gridlines A.0-B.0/0.0 and B.0/0.0-1.0, at 0 feet to 4 feet
Type and Size of Specimens: 2"x 2"x 2"Mortar Cubes
Field Testing Information:
Time Mixed: 11:57 am Flow Slump(in.): 3.0" Supplier: Rio Grande
Time Sampled: 11:58 am Sample Temp: 42° Mix Design: Type S
COMPRESNE STRENGTH:
Specimen No. A B C
Age(days) 7 28 28
Date Tested 5/10/11 5/31/1 l 5/31/11
Maximum Load(lbs.) 12681 13105 16625
Gross Strength(psi) N/A N/A N/A
Net Strength(psi) 3170 3260 4135
Gross Area(in. squared) 4.00 4.02 4.02
Net Area(in. squared) N/A N/A N/A
Design Strength 1800 psi @ 28 Days
Progress Report:
Don Sneed
Field Observer