Loading...
HomeMy WebLinkAbout10-039 Daily Field Reports 63 to 66 REINFORCING STEEL (REBAR) OBSERVATION KOECHLEIN CONSULTING ENGINEERS, INC. Geotechnical and Materials Engineers Lakewood—(303)989-1223 Grand Junction—(970)241-7700 To: Town of Vail Job No. 10-039 Date: ll/18/10 Tom Kassmel,P.E. Town Engineer Report#: 63 Sheet: 1 of 1 Department of Public Works/Transportation 1309 Elkhorn Drive Vail,Colorado 81657 Project: Lionshead Transit Center,Vail, Colorado Weather: � Sunny ❑ Cloudy ❑ Rain ❑ Snow Temp: 42°F± Reinforcing Steel (Rebar) Observations: Type of Structure: (Wall, Grade Beam, Footin�, Slab-on-�rade, etc.): ECO Building Continuous Footing Pad Location of Observations: 4' North of Gridline A.0 to A.3 on Gridline 0 Sheet or Plan Number: S 100, S 101, and 3/S 121 Meets Project Spec. Eco Buildin continuous Footin pad Rebar: 4' North of Gridline A.0 to A.3 on Gridline 0 yes no Bottom: Size: 5 - #5 Spacing: Continuous � ❑ Bottom: Size: #5 Spacing: 1'-0" o.c. transverse � ❑ Dowels: Size: #5 Spacing: 1'-0"o.c. inside face � ❑ Dowels: Size: #7 Spacing: 1'-0" o.c. outside face � ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Splices:(yes/no) no Length: ❑ ❑ Meets Project Spec. Rebar: yes no Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Splices:(yes/no) Length: ❑ ❑ Discrepancies/Remarks: Based on our observations, it is our opinion that the reinforcing steel (rebar) yes no noted 'm this Daily Field Report has been properly placed and has met project specifications. � ❑ Don Sneed Scott B. Myers, P.E. Field Observer Reviewed By SOIL COMPACTION TEST RESULTS To: Town of Vail KOECHLEIN CONSULTING ENGINEERS, INC. Job No. 10-039 Date: ll/19/10 Tom Kassmel,P.E. Report#: 64 Sheet: 1 of 1 Geotechnical and Materials Engineers Town Engineer Subject: Fill Observation and Testine Department of Public Works/Transpartation Lalcewood—(303)989-1223 Retaining Wall Footing and Snow Storage 1309 Elkhorn Drive Grand Junction—(970)241-7700 Slab-on-grade Vail,Colorado 81657 Lionshead Transit Center Vail,Colorado LaboraYo Field Depth MaJCimum Optimum Test Location or Dry Moisture Dry Moisture Percent Pass/Fail Soil Type No. Elevation Density Content Density Content Compaction (feet) cf� (%) cfl (%) 203 43'West of Gridlines&1 and E-E.3 Grade± 130.3 7.9 127.1 6.5 98 Pass Curve#1 SAND Gravell Sil 204 Retest of Test#202,dated 11/17/10 Grade± 130.3 7.9 1211 13.3 93 Fail Curve#1 SAND Gravell Sil Weather: ❑ Sum� � Cloud ❑ Rain ❑ Snow Tem : °F± ❑ Fill Tested Meets Specifications. Specification Compaction&Material: 98%(Retaining Wall)or 95%(Slab-on-grade)of � Fill Tested Does Not Meet Specifications as Indicated by Test Number(s)204 Standard Proctor AASHTO T 99,+2%to-2%of Optimum Moisture Content and Should be Removed or Reworked. Type and Number of Earth Moving Units: 1-Trackhoe � Contractor Advised. ❑ Full Time Observation. � Part Time Observation. Type and Number of Compaction Units: 1-Walk-behind Progress Report: Field engineer arrived on-site, as requested, to observe and test the structural fill below the retaining wall footing and snow storage slab-on-grade. Test Number of Passes: Varies Thickness of Lift: N/A results indicate that moisture and density tests performed at the noted location far the Method of Adding Moisture: None retaining wall have met project specifications. However,test results indicate that moisture T�,�s re�o�t p�zs�„cs op�n�ons formea as d��suir ofou�oeser�ar��,ns anaior�o�„pa�t�o„resr�ng ofri,e f�u aur�n�rn;s��s�r. and density tests performed at the noted location for the slab-on-grade have failed to meet We have relied on the contractor to continue applying the recominended compactive effort and mois[ure to the fill during j7r0�0Ct SpeCl�CatlOriS. times when our observer is not observing operations. Tests are made of the fill only as belicved necessary to calibrate our observei's jud ment Test data are not the sole basis for o inions on whether the filL meets s ecifications. Don Sneed Scott B. Myers, P.E. Field Observer Reviewed By REPORT OF CONSTRUCTION ACTIVITIES KOECHLEIN CONSULTING ENGINEERS, INC. Geotechnical and Materials Engineers Lakewood—(303)989-1223 Grand Junction—(970)241-7700 To: Town of Vail Job No. 10-039 Date: 11/20/10 Tom Kassmel,P.E. Town Engineer Report#: 65 Sheet: 1 of 1 Department of Public Works/Transportation 1309 Elkhorn Drive Vail,Colorado 81657 Project: Lionshead Transit Center,Vail, Colorado Weather: � Sunny ❑ Cloudy ❑ Rain ❑ Snow Temp: 46°F± Construction Activities/Observations: Field engineer arrived on site, as requested, to perform moisture and density testing below the western-most retaining wall. The area was excavated to grade from Gridline E-E.0 to Gridline �D.O but had not been compacted. The soils exposed in the lowest area were not wet and just needed to be compacted. However, at the first step up and on, the soils in this area were wet and very soft between Gridlines�D.O and�D.S. The contractor proposes to remove approximately 2 feet of the material, place geogrid, and then bacicfill with suitable material. No moisture and density testing was performed during this site visit. Don Sneed Scott B. Myers, P.E. Field Observer Reviewed By REINFORCING STEEL (REBAR) OBSERVATION KOECHLEIN CONSULTING ENGINEERS, INC. Geotechnical and Materials Engineers Lakewood—(303)989-1223 Grand Junction—(970)241-7700 To: Town of Vail Job No. 10-039 Date: ll/23/10 Tom Kassmel,P.E. Town Engineer Report#: 66 Sheet: 1 of 1 Department of Public Works/Transportation 1309 Elkhorn Drive Vail,Colorado 81657 Project: Lionshead Transit Center,Vail, Colorado Weather: � Sunny ❑ Cloudy ❑ Rain ❑ Snow Temp: 40°F± Reinforcing Steel (Rebar) Observations: Type of Structure: (Wall, Grade Beam, Footin�, Slab-on-�rade, etc.): wa��ay Topp�ng s�ab ana Eco Bu�id�ng wali Location of Observations: Gridlines E C to E-D/E-1, E-D.3 to End of Walkway, and A.0-A.5/1.0 Sheet or Plan Number: 4/5316 and 3/S 121 Meets Project Spec. Walkway Topping Slab Rebar: Gridlines E-C to E-D/E-1 and E-D.3 to End of Walkway yes no U-bar Size: #3 Spacing: 1'-4"o.c. each side � ❑ Horizontal: Size: 2 - #4 Spacing: Continuous each side � ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Splices:(yes/no) yes Length: 2'-0" � ❑ Meets Project Spec. ECO Building Wall Rebar: Gridlines A.0-A.5/1.0 yes no Vertical: Size: #5 Spacing: 1'-0"o.c. inside face � ❑ Vertical: Size: #7 Spacing: 1'-0"o.c. outside face � ❑ Horizontal: Size: #5 Spacing: 1'-4" o.c. each face � ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Size: Spacing: ❑ ❑ Splices:(yes/no) no Length: ❑ ❑ Discrepancies/Remarks: Based on our observations, it is our opinion that the reinforcing steel (rebar) yes no noted 'm this Daily Field Report has been properly placed and has met project specifications. � ❑ Mike Brath Scott B. Myers, P.E. Field Observer Reviewed By