Loading...
HomeMy WebLinkAbout10-039 Fireproofing 1-27-11 � j FIREPROOF'INC 8494WHEATGRASSCIRCLE. PARKER, CO 80134 Il`ISPECTION REPORT 303-957-8436 WESTERN STATES INSPECTION PAGE 1 oF 2 CLIENT KOECHLIEN CONSULTWG ENG[NEERS PROJECT/JOB# KCE# 1 0-039 CLIENT PO# LIONSHEAD TRANS[T CENTER DATE 1-27-1 1 CODE INTERNATIONAL BUILDING CODE HOURS OF SHIFT 1 2:00 PM To 6:00 PM SPECIFICATION PROJECT SPECS. MILEAGE TO 1 OO MILEAGE FROM 1 OO DAY OF WEEK THURSDAY INSPECTOR ROBERT H. POLLOCK TOTAL HOURS TODAY (6) ASSISTAN7 N/A TOTAL MILEAGE 200 P�R DIEM YES NO X CLIENT REP. SCOTT MEYER (KCE) REPORT# LTC-07 REMARKS: LIONSHEAD TRAfVSIT CENTER 350 S. FRONTAGE RD. VAIL, CO. 1) TRAVEL TO PROJECT S1TE, AS REQUESTED. 2) CONDUCT VISUAL INSPECTION AND REQUIRED THICKNESS TESTING OF"SPRAY APPLIED FIRE RESISTNE MATER[AL'� ON BUILDWG STRUCTURAL MEMBERS. 3) THE FOLLOWING TYPES OF TESTWG WILL BE CONDUCTED,AS APPLICABLE: [,�I VISUAL INSPECTION &THICKNESS TESTING (ASTM sPEC. E605 & IBC) [B] DRY DENSITY TESTING OF II�I-PLACE SFRM (ASTM sPEC.. E605 &IBC) [C] ADHESION/COHESION TESTWG OF IN-PLACE SFRM (ASTM sPEC. �736 & lBC) 4) SEE ATTACHED REPORT FOR DETAILS. � ��\ � Q,�G ,Z'�. � �,\� �j0 Py �R �G � ICC SPEGIAL INSPEGTOR �SPRAY APPLIED FIREPROOFI[VG� CERT. #087521-86 ~ SIGI�IATURE ROBERT H. POLLOCK � • v4C�� (ICC SPECIAL INSPECTOR) F I R E P ROO F I N G 8494 WHEATGRASS CIRCLE. PARKER, CO 80134 . � INSPECTIOI`I REPORT 303-957-8436 WESTERN STATES WSPECT[ON Pa�E 2 oF 2 CLIENT KOECHL[EIV CONSULTING ENGINEERS PROJECT/JOB# KCE# 1 0-039 CLIENT PO# LIONSHEAD TRANSIT CENTER DATE 1-27-1 1 CODE IIVTERNATIOI�IAL BUILDWG CODE HOURS OF SHIFT PG. �I PM TO PG. l PM SPEC[FICATION PROJECT SPECS. MILEAGE TO PG. 1 MILEAGE FROM PG. 1 DAY OF WEEK THURSDAY INSPECTOR ROBERT H. POLLOCK TOTAL HOURS TODAY PG. 1 ASSISTANT N/A TOTAL MILEAGE PG. 1 PER D1EM YES NO X CLIENT REP. SCOTT MEYER (KCE) REPORT# LTC-07 REMARKS: � STAIR CANOPY STRUCTURAL STEEL FRAMING � 1) OBSERVE APPLICATION OF'INTUMESCENT MAST►C FIREPROOFING� (ALBI CLAD 80O) W PROGRESS AT WEST CAI�IOPY. NO DISCREPANCIES WILL BE NOTED. *WEST CANOPY* 2) CONDUCT VISUAL INSPECTIOt�i OF AREAS HAVING FINAL COAT OF PRODUCT APPLIED TO VERT. COLUMNS A[VD BEAMS.THE REQUIRED THICKNESS IS BE1NG ACHfEVED,APPLICATION SHALL BE COIVSIDERED ACCEPTABLE. (WEST CAIVOPY) �EAST CANOPY� 3) CONDUCT VISUAL 1NSPECTION OF APPLICATION OF PRIMER,AND LATHE. NO DISCREPANCIES V�IILL B�NOTED. 4) ADDITIONAL INSPECTION WILL BE CONDUCTED AS NEEDED. � \� � QF 4�6 � F� �6 � QQ��c '�` QD � 1CC SPECIAL INSPECTOR '�SPRAY APPLIED FIREPROOFING� CERT. #08752'[-86 � SfGNATURE ROBERT H. POLLOCK �R • \��\��� (ICC SPECIAL INSPECTOR)