Loading...
HomeMy WebLinkAbout10-039 Fireproofing 2-15-11 - F I RE PROO F I N G 8494 WHEATGRASS CIRCLE. PARKER,CO 80134 � - INSPECTIOI`I REPORT 303-957-8436 ��� � WESTERN STATES INSPECT[ON PAGE 1 OF 3 CLIENT KOECHLIEN COIVSUI�TING ENGINEERS PROJEC7/JOB# KCE# 1 0-039 CLIENT PO# LIONSHEAD TRAI�ISIT CENTER DATE 2-1 5-1 1 CODE WTERNATIONAL BU[LDING CODE HOURS OF SHIFT C:OO PM TO 2:00 PM SPECIFICATION PROJECT SPECS. MILEAGE TO 9 00 MILEAGE FROM 1 OO DAY OF WEEK TUESDAY 1NSPECTOR ROBERT H. POLLOCK TOTAL HOURS TODAY (6) ASSISTANT N/A TOTAL MILEAGE 2O0 PER DIEM YES NO X CLIENT REP. SCOTT MEYER (KCE) REPORT# LTC-08 REMARKS LIONSHEAD TRANSIT CENTER 35O S. FRONTAGE RD. VAIL, CO. 1) TRAVEL TO PROJECT SITE,AS REQUESTED. 2) CONDUCT VISUAL WSPECTfON AND REQUIRED THICKNESS TESTING OF "SPRAY APPLIED FIRE RESISTIVE MATERIAL`� ON BUILDING STRUCTURAL MEMBERS. 3) THE FOLLOWING TYPES OF TESTI(�IG WILL BE CONDUCTED,AS APPLICABLE: [�] V[SUAL INSPECTION &THICKNESS TESTIf�IG (ASTM sPEC. E605 &IBC) IB� DRY DENSITY TESTING OF II�I-PLACE SFRM (ASTM SPEC.. E605 &1BC) [C] ADHESION / COHESION TES711�iG OF II�i-PLACE SFRM (ASTM sPEC. E736 & IBC) 4) SEE ATTACHED REPORT FOR DETAILS. `- OF� � �Q �� O� �,�� 0�1 P,� �� . �G � ICC SPECIAL INSPECTOR �SPRAY APPLIED FIREPROOFWG'� CERT. #087'rJ2 1-86 � SIGNATURE ROBERT H. POLLOCK � � Qex-�(.00� (ICC SPECIAL INSPECTOR) ` F I RE P ROO F I N G 8494 WHEATGRASS CIRCLE. PARKER, CO 80134 � m� INSPECTION REPORT 303-957-8A.36 WEST�RN STATES INSPECTION PAGE 2 oF 3 CLIENT KOECHLIEN CONSULTING ENGINEERS PROJECT/JOB# KCE# 1 0-039 CLIENT PO# LIONSHEAD TRANSIT CENTER DATE 2-1 5-1 1 CODE INTERIVATIONAL BUILDING CODE HOURS OF SHIF-f PG. 1 PM To PG. 1 PM SPEC[FICATION PROJECT SPECS. MILEAGE TO PG. 1 MILEAGE FROM PG. 1 DAY OF WEEK TUESDAY [NSPECTOR ROBERT H. POLLOCK TOTAL HOURS TODAY PG. 1 ASSISTANT N/A TOTAL M[LEAGE PG. 1 PER D�E�vt YES NO X CL[ENT REP. SCOTT MEYER (KGE) REPORT# LTC-08 REMARKS: � S7�AIR CANOPY STRUCTURAL STEEL FRAMING � �WTUNIESCENT MASTIC FIREPROOFING� (ALBI CLAD 8O0) �EAST& WEST CANOPY� 1) CONDUCT VISUAL INSPECTION OF FINAL COAT OF PRODUCT APPLIED TO VERTICAL COLUMNS AND BEAMS.THE REQUIRED THICKNESS HAS BEEN ACHIEVED,APPLiCAT10N SHALL BE CONSIDERED ACCEPTABLE. 2) CERTIFICATE OF COMPLIANCE ATTACHED. � � �,�' O 0 'C �� 52 � �� �o , \l �`Z` . 5 �G "' lCC SPECIAL INSPEGTOR �SPRAY APPLIED FIREPROOF[NG� CERT. #08752 i-86 � SIGNATURE ROBERT H. POLLOCK � . ��X��k�._ (ICC SPECIAL INSPECTOR) 3 oF3 �— � 8494 WHEATGRASS CIRCLE PARKER,CO 80l 34 303-957-8436 j �z.. �� "�i.. .�a WESTERN STATES INSPECTION CO. CERTIFICATE OF COMPLIANCE DATE: FEBRUARY 'I 5, 201 1 CLIENT: KOECHLEIN CONSULTING ENGINEERS (� 0-039) PROJECT: LIONSHEAD TRANSIT CENTER INSPECTION: " INTUMESCENT MASTIC FIREPROOFING " THIS IS TO CERTIFY THAT WESTERN STATES INSPECTION (WSI), TO THE BEST OF MY KNOWLEDGE HAS COMPLIED WITH THE REQUIREMENTS OF THE PURCHASE AGREEMENT/ORDER TO PROVIDE THE REQUIRED INSPECTION OF "INTUMESCENT MASTIC FIREPROOFING". THE PROJECT REFERENCED ABOVE SHALL BE CONSIDERED IN COMPL[ANCE WITH ALL APPLICABLE GOVERNING CODES, STANDARDS, SPECIFICATIONS AND WORKMANSHIP PROVISIONS, AS WELL AS THE CONTRACT DOCUMENTS. WESTERN STATES INSPECTION ����� ROBERT POLLOCK G� �� ICC SPECIAL.WSPECTOR ^���OO��� �C.�,�0�\p�e$�2� Q�O�G��� � r�Q �GG i I I I I