HomeMy WebLinkAbout10-039 Slump Air 1-5-11 Koechlein Consulting Engineers, Inc.
Geotechnical and Materials Engineers
12364 W. Alameda Pkwy YSuite 110 YLakewood, CO 80228-2845
� www.KCE-Denver.com
LAKEWOOD GRAND JUNCTION
(303) 989-1223 (970) 241-7700
(303) 989-0204 FAX (970) 241-7783 FAX
To: Town of Vail
Tom Kassmel,P.E. Job No: 10-039
Town Engineer Date: 1/5/11
Department of Public Works/Transportation Sheet: 1 of 1
1309 Elkhorn Drive
Vail,Colorado 81657
Report of Concrete Placement Observations
Project: Lionshead Transit Center, Vail, Colorado
Specifications: Slump 4�1.5 inches Air Content: N/A
Supplier Lafarge Mix LD. RMXUH45GD8V Ambient Temp. Range 19°-28°F
Test Truck Time Time Time Mix Cubic Yards Water
No. Na Ticket No. gatched Arrived Placed Time Sampled Design Load/ Added
Strength Cumulative Gallons
1 4780729 85822890 8:54 am ]0:21 am 10:31 am 10:35 am 4000 10/18.50 8
2 4780639 85822891 9:51 am 11:03 am 1 1:09 am 11:]2 am 4000 18.50/18.50 8
Air �'et
Test Unit Concrete
Slump (In.) Content Yield Remarks
No. �o�o� Weight Temp.( F)
(PCF)
1 5.25 1.2 147.4 N/A 57 Sampled at point of discharge.
2 3.75 1.6 147.8 N/A 56 Sampled at point of discharge. 1 set of 5
cylinders cast.
Progress Report:
Don Sneed Scott B. Myers, P.E.
Field Observer Reviewed By