HomeMy WebLinkAbout10-039 Slump Air 11-17-10 Koechlein Consulting Engineers, Inc.
Geotechnical and Materials Engineers
12364 W. Alameda Pkwy YSuite 115 YLakewood, CO 80228-2845
� www.KCE-Denver.com
LAKEWOOD GRAND JUNCTION
(303) 989-1223 (970) 241-7700
(303) 989-0204 FAX (970) 241-7783 FAX
To: Town of Vail
Tom Kassmel,P.E. Job No: 10-039
Town Engineer Date: 11/17/10
Department of Public Works/Transportation Sheet: 1 of 1
1309 Elkhorn Drive
Vail,Colorado 81657
Report of Concrete Placement Observations
Project: Lionshead Transit Center, Vail, Colorado
Specifications: Slump 4�1.5 inches Air Content: 6%�1.5%
Supplier Lafarge Mix LD. RMXCE45DG8V Ambient Temp. Range 30°-40°F
Test Truck Time Time Time Mix Cubic Yards Water
No. Na Ticket No. gatched Arrived Placed Time Sampled Design Load/ Added
Strength Cumulative Gallons
1 4780811 85909579 9:38 am ]0:34 am 10:43 am 10:45 am 5000 3.25/6.50 0
lA 4780811 85909579 9:38 am 10:34 am 10:43 am 10:54 am 5000 3.25/6.50 0
2 4780729 85909580 10:40 am 11:18 am 11:28 am 11:33 am 5000 6.50/6.50 0
Air �'et
Test Unit Concrete
Slump (In.) Content Yield Remarks
No. �o�o� Weight Temp.( F)
(PCF)
1 3.25 8.1 137.7 N/A 59 Sampled at point of discharge.
lA N/A 5.5 142.9 N/A N/A Sampled at point of placement.
2 3.50 7.0 140.6 N/A 56 Sampled at point of discharge. 1 set of 4
c linders cast.
Progress Report:
Don Sneed Scott B. Myers, P.E.
FieldObserver Reviewed By