Loading...
HomeMy WebLinkAbout10-039 Slump Air 12-15-10 Koechlein Consulting Engineers, Inc. Geotechnical and Materials Engineers 12364 W. Alameda Pkwy YSuite 110 YLakewood, CO 80228-2845 � www.KCE-Denver.com LAKEWOOD GRAND JUNCTION (303) 989-1223 (970) 241-7700 (303) 989-0204 FAX (970) 241-7783 FAX To: Town of Vail Tom Kassmel,P.E. Job No: 10-039 Town Engineer Date: 12/15/10 Department of Public Works/Transportation Sheet: 1 of 1 1309 Elkhorn Drive Vail,Colorado 81657 Report of Concrete Placement Observations Project: Lionshead Transit Center, Vail, Colorado Specifications: Slump 4�1.5 Air Content: 6f1.5 Supplier Lafarge Mix LD. RMXCE45DG8V Ambient Temp. Range 28°F Test Truck Time Time Time Mix Cubic Yards Water No. Na Ticket No. gatched Arrived Placed Time Sampled Design Load/ Added Strength Cumulative Gallons 1 4780729 85909684 10:16 am ]0:53 am 1 1:14 am 11:18 am 5000 10/15 15 2 4780730 85909685 11:50 am 12:24 pm 12:30 pm 12:34 pm 5000 15/15 5 Air �'et Test Unit Concrete Slump (In.) Content Yield Remarks No. �o�o� Weight Temp.( F) (PCF) 1 3.75 5.9 42.58 141.1 60 Sampled at point of discharge. 1 set of 5 cylinders cast. 2 4.75 7.3 42.06 139.0 59 Sampled at point of discharge. Progress Report: Don Sneed Scott B. Myers, P.E. Field Observer Reviewed By