HomeMy WebLinkAboutLH FS-1-FP8 VALVE. FIRE SPRINKLER CONTROL STATION DIAGRAM NO SCALE 4" FIRE STAND PIPE. 2" FIRE DRAIN PIPE. PIPING SHALL BE HYDRAULICALLY FIRE STANDPIPE AND SPRINKLER NOTE: SIZED. F SUPERVISORY SWITCH. WALL CABINET IF REQUIRED. A HOLE EQUAL TO THE FLOW OF ONE AUXILIARY DRAIN 1" UNION W/BRASS ORIFICE DISC WITH SPRINKLER HEAD. D D D TEST VALVE. SIGHT GLASS. 18" DOWNSTREAM OF ELBOW. TSFS REDUCER. FLOW SWITCH. 2 1/2" FIRE LINE TO SPRINKLERS. FIRE DEPT. CONNECTION. FIRE ENTRY PIPING DIAGRAM SHUT-OFF VALVE. FLOW SWITCH TO ALARMS, SEE SPECS. 2" DRAIN VALVE; PIPE INDIRECT TO FLOOR DRAIN, 4" FIRE SERVICE FLANGE. TEST VALVE; PIPE TO OUTSIDE. F C.W. SERVICE VALVE. BALL DRIP NO SCALE D FS D D FLOOR. TYP. EXTERIOR BLDG. WALL. TO FIRE PROTECTION SYSTEMS. F 4" 4" 3" 3" 2" 4" 4" 4" 2" 4" 4" SYSTEM HAS OVER 100 PSI. THERE MUST BE A HANGER WITHIN 1' OF SPRINKLER HEAD AT THE END OF BRANCH LINES AND ARM OVERS. MILE HIGH DESIGN GROUP 5151 Bannock St. Denver, CO 80216 303-291-1012 303-383-5023 FAX firesprinkler@amsprink.com A FIRE SPRINKLER DESIGN COMPANY ACCEPTING THIS COPY IS DEEMED AS AGREEING TO THE FOLLOWING: THIS DRAWING COPY, ITS CONTENTS, INFORMATION AND PRINCIPALS OF DESIGN ARE THE EXCLUSIVE PROPERTY OF THE FIRE PROTECTION CONTRACTOR LISTED AND MILE HIGH DESIGN GROUP, LLC AND IS BEING SUBMITTED TO YOU WITH THE UNDERSTANDING THAT IT IS NOT TO BE REPRODUCED, COPIED OR MODIFIED IN ANY MANNER; NEITHER SHALL IT BE RELAYED IN WHOLE OR IN PART TO ANY OTHER INDIVIDUAL OR FIRM FOR ANY OTHER PROJECT OR EXTENSION OF THIS PROJECT EXCEPT THRU WRITTEN AGREEMENT WITH THE FIRE PROTECTION CONTRACTOR AND MILE HIGH DESIGN GROUP, LLC. ERRORS AS A RESULT OF THIS FILE BEING ELECTRONICALLY TRANSMITTED ARE BEYOND THE CONTROL OF AND ARE NOT THE RESPONSIBILITY OF THE FIRE PROTECTION CONTRACTOR OR MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR INSTALLATION OR INSPECTION OF WORK INSTALLED. THESE PLANS ARE DIAGRAMMATICAL ONLY. ON SITE COORDINATION MUST BE ARRANGED WITH ALL OBSTRUCTIONS, i.e.: MECHANICAL, ELECTRICAL, AND STRUCTURAL. ANY ALTERATIONS FROM ENGINEERED DRAWINGS MUST BE APPROVED BY MILE HIGH DESIGN GROUP. MILE HIGH DESIGN GROUP IS NOT RESPONSIBLE FOR LAYOUT DESIGN ISSUES OR CONFLICTS WITH ANY OBSTRUCTIONS. IF ADDITIONAL FIRE SPRINKLER PIPING AND/OR FIRE SPRINKLER HEADS ARE REQUIRED THIS WILL BE THE RESPONSIBILITY OF THE FIRE SPRINKLER CONTRACTOR. ALL CHANGES MUST ME APPROVED BY MILE HIGH DESIGN GROUP, LLC THE OWNER IS RESPONSIBLE TO PROVIDE SUFFICIENT HEAT THROUGHOUT THIS BUILDING TO PREVENT FREEZING OF WATER IN THE FIRE SPRINKLER SYSTEM -Not considered to be part of welcome center.