HomeMy WebLinkAboutB11-0208 expired NOTE: TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
,�
�w�o�v�: ..
Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657
p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149
COMBINATION BLDG PERMIT Permit #: B11-0208
Project #: PRJ11-0252
Job Address: 616 W LIONSHEAD CIR VAIL Applied.....: 07/12/2011
Location......: CONCERT HALL PLAZA-THE LITTLE DINER Issued... : 08/09/2011
Parcel No....: 210106318006
OWNER HUGHES LAND HOLDING TRUST 07/12/2011
3324 STATE ST STE C
SANTA BARBARA
CA 93105
APPLICANT WESTERN VALLEY GLASS 07/12/2011 Phone: 970-625-1456
146 DANIEL AVE
RIFLE
CO 81650
License:C000003200
CONTRACTOR WESTERN VALLEY GLASS 07/12/2011 Phone:970-625-1456
146 DANIEL AVE
RIFLE
CO 81650
License:C000003200
Description:
ADDITION OF CONDENSER UNIT ON ROOF.REPLACEMENT OF EXISTING
AIR INTAKE ON ROOF.ADDITION OF NEW SMALL LOUVERED AIR
INTAKE IN BREEZEWAY ABOVE FRONT WINDOWS.ADDITION OF
EVAPORATIVE COOLER MODULE ONTO EXISTING MAKEUP AIR UNIT ON
ROOF.REPLACEMENT OF EXISTING RED WOODEN RESIDENTIAL PATIO
ENTRY DOORS WITH RED COMMERCIAL ALUMINUM ENTRY DOORS.
Occupancy: Type Construction: Valuation: $23,184.00
....................,,...,...............,,,......,.,......,....,,,..,..,.,......... FEE SUMMARY ...........,.....,,...............,,.....,.....,..,,......,..,,,.......,........,..
Building Permit-----------> $377.25 Bldg Plan Check----------> $245.21 Use Tax Fee-----------------------> $263.68
Electrical Permit---------> $115.00 Elec Plan Check-----------> $74.75 Restuarant Plan Review--------> $0.00
Mechanical Permit------> $360.00 Mech Plan Check--------> $90.00 Additional Fees--------------------> $0.00
Plumbing Permit--------> $30.00 Plmb Plan Check---------> $7.50 Recreation Fee--------------------> $0.00
investigation-----------------------> $0.00
Will Call------------------------------> $20.00
TOTAL PERMIT FEES-------------> $1,583.39
Payments------------------------------> 51,583.39
BALANCE DUE-----------------------> $0.00
......�............................................................................x....,,................,�,.,,..«.«.....,.,,...............,,.,....................,...............,,..
DECLARATIONS
I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan,and state that all the information
as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure
according to the town's zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town
applicable thereto.
REQUESTS FOR INSPECTION SH LL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM
8:00 AM-4:00 PM.
� �� � z� 11
Signat re Owner or ontr tor Date
l ,. '
Print Name
combination permit_012811
,
�
������!ttJ.J a
aRte4ir*�ftr4*xf�Ir4+wf f f fYrYrYrYY'�R�RY`'kM�k�k'krtR*�F*1*****fef*f*}4##wlr#*hfrfiiiFhf rt�lrYeirtil'frMYrkYrY`firtRRiPYrY'i1'i1'hM'YlY'4i4f k�k1`1`4k*fr#41�#1`*****ltef`�RtMMf�frfrRfir}f tr}l�tfr***fr*4kt(t`te+**R**f Irt ir#4'k4f**MYef i(f iFT'Y'f f i1'trtrlril'#'iF*f4Yr•
CONDITIONS OF APPROVAL TO BE MET PRIOR TO FINAL SIGN OFF
Permit#: 611-0208 Address: 616 W LIONSHEAD CIR VAIL
Owner: HUGHES LAND HOLDING TRUST Location:
CONCERT HALL PLAZA-THE LITTLE DINER
.....................................................................................................,...........................................»...,..,........,,...,............,..
Cond: CON0012022
Prior to final inspections, the applicant shall paint the
air intake louver above the front window to match the color
of the wall siding. Prior to final inspection, the
applicant shall paint all new rooftop equipment a flat gray
color.
combination permit_012811
�
�
t V 1►!�i V� 1"�I.tL •
*«*********�*.,,�*,««*****.*,.,.*.******«*«„«*,.*„**,.**,.*,.�***,.«*,.,.*,..,.,..***,.****„««*********««»***,�**�*,.*******.*..,.,,*„*.«««„***«******,�****,.****,,,.,,,.*„
REQUIRED INSPECTIONS AND STATUSES
Permit#: 611-0208 Address: 616 W LIONSHEAD CIR VAIL
Owner: HUGHES LAND HOLDING TRUST Location:
CONCERT HALL PLAZA-THE LITTLE DINER
,,,,*..,*,.**.*********.,,,,******„*******************,,,,.,**.,****«*«««*««*****«************„********,.***«*««**«***************«*«««««***«««*********«***,.***
Item: 00534 PLAN - FINAL C/O
Item: 00030 BLDG-Framing
Item: 00120 ELEC-Rough
Item: 00200 MECH-Rough
Item: 00190 ELEC-Final
item: 00390 MECH-Final
Item: 00090 BLDG-Final
combination permit_012811
***************************************************�************************+**************�
TOWN OF VAIL, COLORADO Statement
*******�*********************+**********+****************************+*�***++*****+*********
Statement Number: R110000951 Amount: $1,341.00 08/09/201112:55 PM
Payment Method:Credit Crd Init: LC
Notation: CREDIT CARD
FROM MARGUERITE A. LITTLE
-----------------------------------------------------------------------------
Permit No: B11-0208 Type: COMBINATION BLDG PERMIT
Parcel No: 2101-063-1800-6
Site Address: 616 W LIONSHEAD CIR VAIL
Location: CONCERT HALL PLAZA - THE LITTLE DINER
Total Fees: $1, 583 .39
This Payment: $1, 341.00 Total ALL Pmts: $1, 583 .39
Balance: $0.00
****��*******************�******************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 BUILDING PERMIT FEES 377.25
EP 00100003111100 ELECTRICAL PERMIT FEES 115.00
MP 00100003111100 MECHANICAL PERMIT FEES 360.00
PF 00100003112300 PLAN CHECK FEES 175.07
PP 00100003111100 PLUMBING PERMIT FEES 30.00
UT 11000003106000 USE TAX 4% 263.68
WC 00100003112800 WILL CALL INSPECTION FEE 20.00
-----------------------------------------------------------------------------
"�<.+ • `��� Department of Community Development
�R� a��' ���-�• '�} , � .�, � 75 South Frontage Road
��t.� �� •. Vail, Colorado 81657
. I �� '�`� Tel: 970-479-2128
� � ` Web: www.vailgov.com
�
, �'�� Development Review Coordinator
_ � `� �,� . .
�IURI�V�'i , .�z _. � '+�� .r' � �__s�;��,:`�
.�.` -
BUILDING PERMIT APPLICATION
(Separate applications are required for alarm &sprinkler)
Project Street Address: Project#: Q�I�-fl a5 a
616 W. Lionshead Cir. 204 (��n `
DRB#: 1�KA7 L 1 OoZOO
(Number) (Street) (Suite#)
Concert Hall Plaza Building Permit#:��!' �o�(�$
Building/Complex Name: -
Lot#: Block# Subdivision:
Contractor Information
Business Name: Westem Valley Glass Work Class: New( ) Addition ( ) Alteration(✓)
Business Address: 146 Daniel Ave.
Type of Building:
City R�fle State: CO Z�p: 81650 Single-Family( ) Duplex( ) Multi-Family( )
Contact Name: Mike Banks Commercial(✓) Other( )
Contact Phone: �970)625-1456 Work Type: Interior( ) Exterior( ) Both( )
Contact E-Mail: �9inc@qwestoffice.net
Valuation of
Work Inctuded Plans Included Work
Contractor Registration Number:
Electrical (✓)Yes ( )No (✓)Yes ( )No $1,000
X Mechanical (✓)Yes ( )No (✓)Yes ( )No $17,945
Owner/Owner's Representative Signature(Required) Plumbing (�)Yes ( )No (✓)Yes ( )No $1,139
Project Information
Building (�)Yes ( )No (✓)Yes ( )No $3,100 i
Owner Name: I he Llttle Umer-linan Little
Value of all work being performed: �23,184.00
Parcel#: 2101-063-1800-6 (value based on IBC Section 109.3 8 IRC Section 108.3�
(For Parcel If,contact Eagle County Assessors Office at(970-32&8640 or visit
www.eaglecounty.us/patie) Electrical Square Footage
Detailed Scope and Location of Work: P�ease see attached sheet. � I
(use additional sheet if necessary)
For Office Ose Only: Date Received:
Fee Paid: � � � � � v �
Received From:
Cash Check# � �(f� � 7 2���
CC: Visa/ MC Last 4 CC # exp date:
A�tn # TOWN OF VAIL
OI-Jan-I1
Building Permit Application
Detailed Scope and Location of Work:
-Replacement of existing HVAC system above ceiling tiles in front of restaurant
near the windows with new 4 ton air handler and 15kw heater coil as well as all
associated ductwork and new touvered intake in front breezeway above front
entrance.
-Addition of new 3.5 ton condensing unit on roof for the replacement HVAC
system.
-Utilization of the existing curbing from old HVAC unit intake for use by the new
condensing unit and evaporative cooler for plumbing, electrical, and mechanical
access for new units on roof.
-Addition of Evaporative Cooler Module onto existing Makeup Air Unit on roof.
-Modification of existing Makeup Air Unit and E�aust Fan with new motors,
belts, and pulleys to handle new Evap. Cooler and HVAC system.
-All necessary electrical, mechanical, and plumbing connections for replacement
air handler & heater, new condenser unit, and evaporative cooler module addition.
-Test and balance of entire HVAC system.
-Replacement of existing red wooden residential patio entry doors with red
commercial aluminum storefront entry doors.
. '��-� �,., �_ .,. ,..,
- �.y� �� - � ° n - -�
~ ; � �'� ..._
� �r�:��.�
.
- __� .�.... � I�� � � � �.� �.
�� _... __ _ _ �l �
..�.. -
-----
,� � �� __ �� �� ��i�
� // �� n �� w� �a ��
°�r� n n n ---- --�---
� _
'F �� � ■
��:�� �.,... � —
�..�--° T , �� s�
�� �� �
��� �� � ���
��i� 1�f� .� .� �. � �. .. �
. - .. .� �. �. _ � �■i �� . ���
� ��:
,::::. �..�■ �
� . .__ _ . ._ _
.�. �� - �
� =C 1�...1 -� ; : ��
� �-�
�� � 11 N v ��
� . � �
�� �. �*�:_
_ � . :: 1n � i: _. = _� y� _
=�;,,m;,,pLL� _ �_ .. � :�. -.�
�. �,_ .
EFCO's standard entrances are designed for educational facilities,shopping centers, offices and other facilities
requiring security and egress capabilities. EFCO standard entrances are joint plug welded at every corner to provide
superior strength in all applications.Offered in narrow,medium and wide stiles, EFCO standard entrances can
accommodate a wide range of applications.Multiple glazing options provide flexibility to meet specific design
requirements,and the product's ability to accommodate most hardware applications increases its versatility. EFCO's
standard entrances provide the complete solution for your fenestration needs.
Bracket reinforced and deep penetration welded Meets or exceeds most specifications for
corners commercial entrances
Accepts most major brands of locking hardware Able to comply with special hardware
and panic devices specifications
Accommodates up to 1" glazing Flexibility in design requirements for glazing
Accommodates all surface mounted, concealed Unrestricted closer choices
overhead and floor closers
Tall bottom rails available Meets ADA requirements
Variety of cross rails, door sweeps, and crash bars Increases configuration options
available °
Anodized and painted finishes available Multipie options to answer economic
and aesthetic concerns
a Pr/!a Camyuxr
�
,
._ -...
, _. � .w-�� . �. .. w ..:..,, �. ,�.. „w � �;-���,+�4�d� �.
� �� � � � � �� `", 4b � �� � "
- � 1A � "' � # all
,,,� :�, ,: , _�.v �.�� .,_. � _ ,., �,.�-r� .,� .�
, : . �
I � �
��� Tor Rais
0
�
�
� �
nonoM Rau
..�„ i
0
� �
� 0
\
D200 NA[ROW SiIIE(SINGLE DOOt LEAF) D300 MEDIUM STILE(SINGIE DOOR LEAF)
AIR WFILTRATION <.$p CFM/SF @ 1.56 PSF AIR INFILTRATION <.SO CFM/$F�1.56 PSF q-Estimafed vaiues and/or designations
B=Nortstandard s¢e w configuration
D500 WIDE STILE(ANGIE DOOR IEAF) C=Dual glazed
AIR INFILTRATION <.50 CFM/SF @ 1.56 PSF D=I"�nsulafed-1/4"cleatl/2"ai,I/4"dear
E=I"Insulated-1/4"clear(Low Emissivity�,I/2"a'r,l/4"clear
F=I"Insulated-1/4"clear(LOwEmissivity�,I/7'argon,l/4"clear
G=I"Insulatad-i/a"clea[I/2"ai.l/d"dear�Low Em'nsivity)
D400,D300,8 D500 POLYCARBONATE GLASS OR PANEL "'-�aminated Glass Thickness
n-n�o�bwe c,�azi�9 oPno�
GLADNGCHARi 3/16" 1/4" 5/16" IM" 1/4"" 5/16" 1/16" IJ2" 9/16" 5/8" 3N" 1B° ISII6" I" c-ndaptaand/«gasketrequied
MONOLRHICGLASS A A C A A A C C C C b�cok-N/A
INSULATEDGlASS A A
m
e r.n..coMp..�
.•
Door Construction
Door rails and stiles have o depth of 1 3/4",and are constructed of
6063-Tb aluminum alloy.Nominal material wall thickness is.125".Corner
construction utilizes a heavy,concealed,reinforcement bracket that is
deep penetration and fillet welded.See Illustration l.
Weather-Stripping
Single doors are weather-stripped at ihe frame with ASTM E2203
compliant bulb gasket and extruded door stops,which are available in 0
integral,snap-in,and surface mounted varieties.See frame section.All
pairs of doors are dual weather-stripped at ihe astragal with Poly-Pile.
Ha�dware
EFCO standard doors accommodate most hardware types.Doors
0
accept offset pivots,center pivots,butt hinges,or continuous gear
hinges.Maximum security deadbolts,short throw deadbolts,hook °
bolts,latch locks,and flush bolts are a few of the compatible types of Illustration 1
locks.Panic devices include concealed rod devices,rim devices and
removable mullions.Concealed overhead,surface mounted and floor
closers are accommodated.EFCO UltralineT"'push-pulls are standard.
Glazing
Doors are glazed with extruded aluminum,pressure fitting glass stops.
Glazing of 3/16"to 1 1/16"insulated units are availabie.
See Glazing chart for exact size.
�
a Pdra ramy.,,,
OO Copyright 2010 EFCO Corporation Oi/10 1000 COUNTY RD • MONETT,MO 65708 • 800.221.4169 • efcocorp.com
1
�
,
wESrEan vw.EV �
ouss
Project Nama: LITTLE DINNER Date: 6/10/11
Frame Set Name: Frame Set 1 Frame Name: Frame 1 Panets: 1 Rows: 1 �,
Metat Group: 5403 SS/OG D/S: 1 Frame Type: Standard Frams Width: 76 Frame Height: 86 �
Required: 1 Back Member Color: REGAL RED:ULTRAPON Face Member Color: NULL
�c—� 78(O.A.FR) �
I 72
—� 2 �2
� gq 86(O.A.FR)
T T
� � _�
����i---
Page: 1 Of 1
�' _ .."{
AIR HANDLERS
- CB26U H / CBX26U H
LENNOX MERIT�SERIES
^� Up-Flow / Horizontal
E N G 1 N E E R f N G D A T A Bulletin No.2t 0429
December 2006
Supersedes November 2006
� _ —
I
;
i
I
�
,
�
j
!f h�rl�',t�� ���
�._�---�---"' ------'; I
{
��___----�-, � '��
�
4�
4
.,.�
Nominal Capacity - 1.5 to 5 Tons
Optional Electric Heat - 5 to 20 kW
MODEL NUMBER IDENTIFiCATiON
f� 2 �H - 030- 230- 1
Unit Type J � Minor Revision Number
CB-Air Handler(BlowedCoil)
Refrigerant Ty Voltage �I
X=R-410A(No X=R-22) 230=208/230V-lphase-60hz i
Series Nominal Cooling Capacity I
018= 1.5 tons �
Configuration 024=2 tons '�
UH=Up-Flow/Horizontal 030=2.5 tons
036=3 tons
042=3.5 tons
048=4 tons
060=5 tons
FEATURES
CONTENTS
��r�•(Ts:;
Blower Data . .. .. .. .... .. ..... .. .. . .. .. . . Page 5 -- _ ,- Q �..•
Dimensions. ... .. ........ ..... .. ... .... . . Page 9 � � ---__ �• �
<<
Dimensions-Accessories . . ..... ........ . Page 10 �: � �`""��'`�
Electrical Data . .... .. ..... ... ......... ... Page 4 � �L :
Electric Heat Data . . .... .. ....... ......... Page 6 ��`
Features . . . .. .. ... .... .......... .. .. ... . Page 2 ``����
Installation Clearances . . .. .. .. .... .. . .... . Page 5 ' ` �
Model Number ldentification . ....... ... . . .. Page 1 � O .,,,r
Optional Accessories Selection Table . .... .. Page 4 �-� ,y�
Spec�cations . .... . .... .. ........ . .. ..... Page 4 � �` `,
��
��d� X,.;
WARRANTY ;
FEATURES
QBLOWER Side Return Unit Stand(Up-Flow Only)
Resiliently mounted two-speed motor. Raises unit 16 in. above floor for side return air duct
Choice of blower speeds.See blower performance tables. connection.
Speed changes easily accomplished by a simple wiring Eliminates need for wooden platform construction.
change. All aluminum construction.
Blower is easily removed from unit for servicing. Two adjustable frames fit all sizes.
Time Delay Blower Relay See Dimension Drawing.
Relay allows 30 second blower "on" delay before yyall Hanging Bracket Kit(Up-Flow Only)
continuous fan or cooling operation and 30 second btower Allows unit to be hung on wall at any height.
°ofP'deiay after continuous fan or cooling operation. Consists of heavy gauge steel support brackets(one for
CONTR0�5 air handler unit, one for wall mount).
� Transformer and Blower Cooling Relay Screws fumished for fastening one bracket to unit.
24 volt transformer and blower cooling relay furnished as Bolts for fastening one bracket to wall are field provided.
standard.
Factory installed in the unit control box. �LECTRICAL
OPTIONS
Thermostat o�'r�or�s
See Thermostat bulletins in Controls section and Lennox � E�ectric Heat I
Price Book for a complete list of thermostats. Field install internal to unit cabinet.
�CABINET Available in several kW sizes. �� �I
�-�s��:,�
Constructed of heavy gauge galvanized steel. See Electric Heat tables. �,� :�
Powder paint finish. Helix wound nichrome heating . �
Completely insulated with foil faced fiberglass insulation. elements exposed directly in
Removable panels provide complete service access. air stream resulting in instant `� ~ `
Filter access door for easy filter replacement. heat transfer, low element �'?'. "�
Electrical inlets provided in sides and top of cabinet.See temperatures and long !
dimension drawing for locations. service life.
Knock-outs in cabinet for drain connections for up-flow Each element equipped with
(left and right)and horizontal applications. See dimension accurately located limit control with fixed temperature off I
drawing. setting and automatic reset.
Up-FIow/Horizontal Capability(Optional Down-Flow) Thermal sequencer relay brings elements on and off line,
Shipped for up-flow and horizontal left-hand discharge. in sequence and equal increments, with time delay
May be field converted to horizontal right-hand air between each.
discharge by repositioning horizontal drain pan. Initiates and terminates blower operation.
Optional down-flow kit available for field conversion. Heating control relay(s)furnished as standard.
�Anti-Mlcrobial Dual Position Drain Pans Factory assembled with controls installed and wired.
Anti-Microbial additive resists growth Electric heat control wiring plugs into mating connector on
of mold and mildew on drain pan �J��Cro�Il air handler unit.
which improves indoor air quality ' Circuit Breaker Models
and reduces drain line blockage. ECB26-5C6, EC626-7CB, ECB26-10C6, EC62&15CB,
Drain pans designed for up-flow or horizontal EC626-20CB heaters are equipped with circuit breakers
applications.
Deep, comosion resistant high temperabure engineered for overload and short circuit protection.
polymer drain pans have dual pipe drains. Factory wired and mounted on electric heat unit.
See dimension drawing. Current sensitive and temperature actuated.
oar�oNS Manual reset.
Down-Flow Combustible Floor Base(Down-Flow Only) Circuit breakers quatify as disconnect means at unit in
Additive base required for models with electric heat many areas, eliminate the need for field provided
instatled in down-flow position on combustible floors. disconnect.
Down-Flow Conversion Kit Consult local electrical code in your area.
Required for field conversion to down-flow position. Kit Circuit Breaker Cover Kit
consists of drip shields and 2 brackets for repositioning Flexible plastic cover protects circuit breaker.
coil and drain pan. Recommended in areas with high humidity to prevent
Duct Adaptor Kit nuisance tripping.
Kit allows direct connection of the ductwork to the retum Single-poirrt Power Sour9ce Control Box
air opening of the air handler, not required if an external Control Box may be used with optional electric heat when
filter is used or if unit is installed on a platform in up-flow single power supply is connected to multi-circuit electric
applications. See dimension drawing. heat.
Horizontal Support Frame Kit Field installs external to the unit cabinet on either side or
Provides support of unit in horizontal applications. top.
Consists of(2)1 x 1-1/2 x 32-5/8 in.and(2)1 x 3 x 53-7/8 Constructed of heavy gauge steel, baked enamel finish,
in.painted heavy gauge cold rolled steel support channels prepunched mounting holes,etectrical inlet knockouts,and
with assembly and suspending holes. terminal strip.
Bolts and nuts furnished for field assembly. Removeable cover provides easy access.
Suspending rods must be field provided. Dimensions(H x W x D)-7 x 7 x 4 in.
CB26UH/CBX26UH-1.5 to 5 ton Air Handlers/Page 3
SPECIFICATIONS
General Model Number(R-22) CB26UH-018 CB26UH-024 CB26UH-030 CB26UH-03
�� Model Number(R-410A) CB UH-018 CBX26UH-024 CBX26UH-030 CBX26 36 �
Nominal tonnage 1. 2 2.5
Connections SuctionNapor line(o.d.)-in.(mm)sweat 3/4(19 3/4(19) 7/8(22.2) /8(22.2) I
Liquid line(o.d.)-in.(mm)sweat 3B(9.5) 3/8(9.5) 3/8(9.5) 3B(9.5) I
Condensate-in.(mm)fpt (2)3/4(19) 3/4(19) (2)3/4(1 (2)3/4(19)
Indoor Net face area-ft. (m ) 4(0.37) 4 37) 4.88 5) 4.88(0.45)
Coil Tube outside diameter-in.(mm) 3/8(9.5) 3/8(9. (9.5) 3/8(9.5)
Number of rows 3 3 3 3
Fins per inch(fins pe�m) 15(591) 14(551) 14(551) 14(551)
Blower Wt�eel nominal diameter x width-in.(mm) 10 x 6 10 x 6 1 x 8 11 x 8
(254 x 152) (254 x 2) (27 03) (279 x 203)
Blower motor output-hp(W) 1/4(187) 1/ 187) 1!4(18 1/3(249)
Filters Size of filter-in.(mm) 16 x 20 x 1 x 20 x 1 18 x 20 x 1 18 x 20 x 1
(406 x 508 x 25) 06 x 508 x 25) (457 x 508 x 25} 57 x 508 x 25)
ELECTRICAL DATA
Voltage-1 phase(60 hz) 2 /240V 208/240V 208/240V 208 V
2 Maximum overcurrent protection(unit only) 15 15 15 15
3 Minimum circuit ampacity(unit only) 1.5 1.5 1.6 1.8
Shipping Data-1 package-Ibs.(kg) 129(58) 131 (59) 148(67) 148(67)
SPECIFICATIONS
General Model Number(R-22) CB26UH CB26UH-048 CB26UH-060
�� Model Number(R-d10A) CBX26UH 2 CBX26UH-048 BX26UH-0 �
Nominal tonnage 3.5 4 5
Connections Suction�/apor line(o.d.)-in.(mm)sweat 7/8(22. ) 7!8(22.2) /8(22.
Liquid line(o.d.)-in.(mm)sweat 3/8(9. ) 3/8(9.5) 8(9.
Condensate-in.(mm)fpt ( 3/4 19) (2)3/4(19) (2) !4 19)
Indoor Net face area-ft. (m ) 5. ( .54) 7.58(0.70) 8.7 .81)
Coil Tube outside diameter-in.(mm) .5) 3/8(9.5) 3/8 .5)
Number of rows 3 '
Fins per inch(fins per m) 14 1) 14(551) 1 5 )
Blower Wheel nominal diameter x width-in.(mm) x 11 x 8 11 /2
(27 x 2 ) (279 x 203) (2 x 22
Blower motor output-hp(W) 3(249 1/2(373) 2(373)
Filters Size of filter-in.(mm) 1 x 25 x 1 18 x 25 x 1 1 x 25 x 1
(45 x 635 x 2 (457 x 635 x 25) (4 x 635 x 2
ELECTRICAL DATA
Voltage- 1 phase(60 hz) 208/240V 208/240V 208/240V
2 Maximum overcurrent protec6on(unit only) 15 15 15
3 Minimum circuit ampacity(unit only) 1.9 2.6 4.1
Shipping Data-1 package-Ibs. (kg) 172(78) 177(80) 190(86)
�Fil6er is rat furr�shed and rtx�st t�e field supplied.
2 HACR rype drart bieaker a fuse.
3 Refer to National or Canadian Eledrical Code manua�to determirre wire,fuse and disconnec[size requirements.Use wlres suitable for at least 167°F(75°C).
OPTIONAL ACCESSORIES-MUST BE ORDERED EXTRA
-018 -042
MO� -024 6 -048 �
Circuit Breaker Cover Kit 83M85 93M85 85
Down-Flow Combustible Floor Base 1 12W96 12W97 1 97
Down-Flow Conversion Kit 1ZW61 12W61 12W61 1
Duct Adaptor Kit X8103 X8104 X8104 X81
HorQOrrtal Support Frame iGt 56J18 56J18 56J18 18
Side Retum Unit Star►d(UµFlaw Only) 45K 32 45K32 2
Single Pant Power Source Control Box(for Eleclric Heat) 9 21 39 21H39 1H39
Wall Hanging Bracket Ktt(Up-Flow Only) 45K30 45K30 45K30 45K30
CB26UHlCBX26UH-1.5 to 5 ton Air Handlers/Page 4
BLOWER DATA
CB(X)26UH-018 BLOWER PERFORMANCE (X)26UH-024 BLOWER PERFORMANCE
Air Volume at Air Volume at
Extemal Static gp�ific Blower Taps ernal Static Speciflc Blower Taps
Pressure High Low �ssure High Lo I
i w.g. Pa cfm Us cfm Us in.w. Pa cfm Us cfm L/s
25 1020 460 755 340 .10 25 1040 470 10 455
.2 50 960 435 715 325 .20 50 980 445 0 425
.30 75 885 400 675 305 .30 5 905 410 870 395
.40 100 800 365 6 285 .40 1 815 37 785 355
.50 125 690 315 0 260 .50 125 705 0 680 310
.60 150 525 250 00 235 .60 150 35 250 530 250
NOTE-All air dala ex6ermal to unR wilh dry odl and irx:h norrpleaAed air NOTE-All air da�a meas�xed e�Qernal wqh dry coil and 1 irah na}plaaOed air
fiker in place. filBer in place.
Electric heaters hav o appreciable air resistance. Eledric heaters have no appreciabl ir istance.
CB(�26UH-03 LOWER PERFORMA E CB(X)26UH-036 BLO R PER RMANCE
Air lume at 'r Volume at
Extemal Stati Specifi Blower Taps External Static Spec� Biower Taps
Pressure High Low P�$$ure High Low
in.w. . Pa cfm s cfm Us in.w.g. a cfm Us cfm Us
.10 25 1350 10 1145 520 .10 25 1560 705 405 635
.20 50 1290 585 1090 495 .20 50 1480 670 1 0 610
.30 75 1225 555 1030 465 .30 75 1390 630 127 575
.40 100 150 520 960 435 .4 100 1290 585 1185 540
.50 125 1 5 485 875 395 0 125 1170 530 1090 495
.60 125 455 775 365 .60 150 1015 480 975 60
NOTE-AH air dafid rrieasured e�ertml to ' witli dry odl and 1 inch nor�plea�d air NOTE-AN�r data meastxed extert�al to unit wph tky coil and 1 irxh nortplee0eci air
filher in plac:e. fi�in place.
Electric heaters heve no appreciable ir sistance. .
CB(X)26UH-042 BLOWE PE ORMANCE CB(X)26UH-048 BLOWER PERFORMANCE
Afr Volume at Air Volume at
External Static S cific Blower Taps External Static Specific Blower Taps
Preasure High Low P�S��e High Low
in.w. . Pa cfm s cfm Us in.w.g. Pa cfm Us cfm Us
.10 25 1940 8 1785 810 .10 25 1945 880 1870 850
.20 50 1845 83 1705 775 .20 50 1860 845 1790 810
.30 75 1745 790 1615 730 .30 75 1765 800 1700 770
.40 1 1630 740 1515 685 .40 100 1660 155 1600 725
.50 1 1495 680 1400 635 .50 125 1540 700 1485 675 ��
.60 1 1330 630 1265 595 .60 150 1395 660 1350 635
NOTE-IW air daAa red e�ernal to unit wph dry cod and ' �on-pleated air NOT E-Ali ar dat�a rneas�xed e�demal to unR wNh dry coil�d t inch ran�leated air
fi�in ptace. fil0er in plaoe.
Eledric heaters have appreciable air resistance. Electric heaters have no appreciable air resistance.
CB(X)26UH-0 B�OWER PERFORMANCE INSTALLATION CLEARANCES
Extemai S tic Air Volume a Cabinet 0 inch(0 mm)
Specific Biower ps
Pressu H� h W Plenum and Outiet duct on air handler units 1 inch(25 mm)
9
in.w.g. Pa cfm Us cfm Us Plenum and Warm air duct within 3 feet 1 inch(25 mm)
.10 25 2160 980 2075 940 (914mm)of cabinet
.20 50 2065 935 1985 900 Floor Combustible I
.30 75 1960 890 1885 55
.40 '100 1845 835 1775 05
.50 125 1710 775 1645 5 I
.60 150 1550 730 1495 5 II
NOTE-All air meas�xed extemal to wR with dry cal and 1 ir�ch rbr�pleated ar
fil�r in plaoe.
Eledric heaters have no appreCiable air resistance.
C826UH/CBX26UH-1.5 to 5 ton Air Handlers!Page 5
CB26UH - ELECTRIC HEAT DATA
SINGLE PHASE ELECTRIC HEAT CB(X)26UH-048
Bbwer Z Minimum 3 Maximum
Descrlption �r Circuit Overcurrent
input Full Load Ampacity Protection
Volt kVU �Btuh �� Circuit 1 Circuit 2 Circuit 1 Circuit 2 I
5 k ECB26-5(99M64)Terminal Block 208 3.8 12,800 2.6 20.7 --- 30 ---
ECB26-5CB(99M65)Circuit Breaker 220 4.2 14,300 2.5 23.3 - ---
230 4.6 15,700 2.5 --- 3p -_-
240 5.0 17,100 . 23.3 --- 30 ---
7.5 kW EC626-7(99M67)Termina 208 5.6 , 2.6 29.7 --- 45 ---
ECB26-7C6(99M66)Circuit Breaker 2 g 2�5pp 2.5 33.8 --- 45 ---
230 6.9 2.5 33.8 --- 45 ---
240 7.5 25,600 . 33.8 --- 45 ---
10 kW ECB 9M68)Terminal Block 208 7.5 25,600 2.6 . -- 60 ---
E OCB(99M68)Circuit Breaker 220 8.4 28,700 2.5 442 --- 60 ---
230 9.2 31,400 2.5 44.2 --- ---
15 kW ECB26-15CB(99M70)Circuit Breaker 208 11.3 38,400 2.6 38.7 18.1 60 30
220 12.6 43,000 2.5 44.2 20.8 60 30
230 13.5 47,000 2.5 44.2 20.8 60 30
1�'"1� 240 15.0 51,200 2.5 44.2 20.8 60 30
220 16.8 57,300 2.5 . 60
, .2 41.7 60 60
240 20.0 68,200 2.5 442 . 60
IC H -060
B�ower 2 Minimum 3 Maximum
�� Circuit Overcurrent
Model Number Input Full�load Ampacity Protection
Volt kW �Btuh � Circuit 1 Clrcuit 2 Circuit 1 Circu'
��h
W E 5(99M64)Terminal Block 208 3.8 12,800 4.1 22.2 --- 30 --
ECB26-5 9M65)Circuit Breaker 220 4.2 14,300 3.9 24.7 --- 30 ---
230 4.6 15,700 3.9 24.7 --- 0 ---
240 5.0 17,100 3.9 24.7 - 30 ---
7.5 W EC626-7(99M67)Termina ock 208 5.6 19,200 4.1 312 --- 45 ---
ECB26-7CB(99M66)Circuit Brea 220 6.3 21500 3.9 3 --- 45 ---
2 6.9 23500 3.9 5.2 --- 45 --- '
240 . 25,600 35.2 --- 45 --- �
10 k EC626-10(99M68)Terminal Block 208 7.5 600 4.1 40.2 --- 60 ---
ECB26-10C6(99M69)Circuit Breaker 220 8.4 2 3.9 45.6 --- 60 ---
230 9. 31,400 .9 45.6 --- 60 ---
240 0.0 34,100 3. 45.6 --- 60 --- ,
15 k ECB26-15C6(99M70)Circuit Breaker 11.3 38,400 4.1 .2 18.1 60 3p �
220 12.6 43,000 3.9 45. 20.8 60 30
230 13.5 47,000 3.9 45.6 .8 60 30
240 15.0 51,200 3.9 45.6 20. 60 30
20 ECB26-20C8 1)Circuit Breaker 208 15.0 51,200 4.1 40.2 36.1 60
220 16.8 57,300 3.9 45.6 41.7 60 60
230 18.4 62,700 3.9 45.6 41.7 60
240 20.0 68,200 3.9 45.6 41.7 60 60
NOT ircuit 1 Minimum Circuit Ampaci in
�E in e additional blower motor heat capaciry.
Z e er to ational or Canadian Eledrical Code manual to detertnine wlre,fuse and disconnect size requirements.Use wires suitable fa at least 167°F(75°C).
3 HACR rype breaker or fuse.
CB26UH/CBX28UH-1.5 to S ton Alr Handlers/Page 8
DIMENSIONS-INCHES�MM)- UP-FLOW POSITION SHOWN
� B�_�5) LINE VOLTAGE �— C —�
RigM,Left and Top
❑ LOW VOLTAGE
� Right Side Only
AIR FLOW �
A CONDENSATE DRAIN
PIP�NG PLATE(4)
SUCTION (2-1/4 x 3-3/4)
LINE
FILTER ACCESS
F LIQUID OPTIONAL DUCT
LINE ADAPTOR KIT
(Kit allows direct connection of the
dudwork to the retum air opening
oi the air handler,not required if
E an extemal frlter is used
� � a ff unit is inshalled on a
platlorm in up-flow applications.)
3/4
�(19) I
�I � G�1 I�' '�I I� H� I�'� �
2-1/2 t�����) 2-1/2 1-1/2 (Opening) 1-1/2
(�) (�) (3$) (38)
FRONT VIEW SIDE VIEW
Dimension
-018,-024 -030,-036 42,-048 -060
i s mm inches m inches mm ches mm
A 4E'r3/ 1187 51 1295 54 1372 152
8 1&1/2 470 21-1/ 540 21-1/4 540 21-
C 22 9 559 26 660 26 60
D 11 279 2-1/2 318 12 305 11-3/4 298
E 16 406 1&1!2 470 1&3/4 425 17 432
F �1/2 140 152 4 102 4 102
G 13-1/2 16 406 16 406 16 6
H 19 483 19 483 23 584 23
Supply Air Depth 17 432 17 2 21 533 2 533
Opening Width 16-1 419 1&1/4 489 19-1/4 489 1 1/4 489
,i
II
CB26UH/CBX26UH-1.5 to 5 ton Air Handlers/Page 9
ACCESSORY DIMENSIONS- INCHES<MM)
DOWN-FLOW COMBUSTIBLE FLOOR BASE SIDE RETURN UNIT STAND
�_�M (Up-Flow Only)
(38)
�-�n - -
(38)
HANDLER i p i
� �
� �
� SUPPLY I A
� OPENING � Openfnp
I B I (406)
�
� � �
I /
I �.�� s
I i (38) (152)
TOP VIEW 5��� �
I I FRONT
C �wrusras�
� �6� r--D--►� c�a°� --...� �LN�s
Opening �
DOwN-FLOW 1-112(38)
COMBU8TIBLE
FIOOR BASE SIDE VIEW
V�ge 18-024 -030-0 -042-048-060
( 95) (12 j (12W97)
in. m in. mm in. mm
A(floor) 19 48 3/4 552 21-3/4 552
B 16-7/8 429 1 /8 498 19-5/8 498
C 23-1/8 23-1/ 587 27-7l8 708
D(floor) 19-1/ 495 19-1/2 5 26-3/4 679
CB26UHICBX26UH-1.5 to 5 ton Afr Handlers/Page 10
AIR CONDITIONERS
XC14
LENNOX ELITE�Series
� R-410A
E N G 1 N E E R 1 N G DA TA Bulletin No.210484
June 2011
Supersedes May 2011
� ��
� � �'
�� ��
.�� ��
�� �` '.'� � � �•
,,,� .. �„+. �.
f
\ � � � �
1 �� '�� �.+� �
\ �� � ' '^ �
1 �
\ 1 '_' � � ^
� ^�� ;` r,"�. �
�
;� •� �-� �•�, �
\ '\ � ', �
� � �
�
'\ �
'\
,,,,�.., ,.
SEER up to 16.50
1.5 to 5 Tons
Cooling Capacity - 17,300 to 58,000 Btuh
MODEL NUMBER IDENTIFICATION
XC14 - 036 - 230 - 2
Refrigerant 7ype � �— Minor Revision Number
X=R-410A
Unit Type Voltage
C=Air Conditioner 230=208/230V-1 phase-60hz
$e�� Nominal Cooling Capacity
018=1.5 tons
024=2 tons
030=2.5 tons
036=3 tons
041=3.5 tons
042=3.5 tons
047=4 tons
048=4 tons
060=5 tons
FEATURES
CONTENTS � I �
�
AHRI System Matches................................................11 0 �-� �° ,�,
:: -:-��, ;< , ,....��
Dimensions...................................................................9 :: ���: � Q :' ;,..-• � ��n
�. ��1 ..--�• � ��4
Electrical Data...............................................................6 ;: ���..�'"'��, � , ' � .':��
Features........................................................................2 :: ��1� ` ` '� � ���
.- ���� _`'. � ; � i ,%�/�'
Field Wiring...................................................................8 :: ���� < q � ' �� i ,���
1
1
Installation Clearances.................................................8 :: �.���.,� , � '�,.�„�.�„
:.: �'�1'\ .�.� �+..� .
Model Numbe�Identification.........................................1 ,. ���� A � ,��
:. ,�.1� �, ,.��
. -__ : .� ..�i`
Optional Accessories....................................................6 ;. ��1^,��, , �� � � ��
Outdoor Sound Data.....................................................8 ;: ���"^\,\ ° ,,..���"�
,.....,/�/'
. •.���'�'r� \ ',i���
Specifications................................................................6 �: ;��",.,,� � ���
�
;,���� ' � ����.
i:���^��'^�. �;���.
t, ��'�,,,, � �/'
�;��"��•'�`� • ,;� ����
\;���^�>, �' ""' '/�'�'/^�
WARRANTY `1��'�'� � i� ����
, '�'�^q. ` ,;„�� �,.+ ��,� '
Compressor-limited warranty for ten years in ��,� Q Q = � ����
residential installations and five years in non-residential 1� �,�,� `�� ��
installations. � r� '�
. �
All other covered components-five years in �
residential installations and one year in non-residential
installations.
Refer to Lennox Equipment Limited Warranty certificate APPROVA�S
included with unit for specific details. AHRI Certified to AHRI Standard 210/240-2008.
APPLICATIONS Sound rated in Lennox reverberant sound test room
in Accordance with test conditions included in AHRI
SEER up to 16.50. Standard 270-2008.
1.5 through 5 ton. Tested in the Lennox Research Laboratory
Single-phase power supply. environmental test room. Rated According to U.S.
Vertical air discharge allows concealment behind shrubs Department of Energy(DOE)test procedures.
at grade level or out of sight on a roof. Units and components within bonded for grounding to
Matching add-on furnace indoor coils or air handlers meet safety standards for servicing required by UL,
provide a wide range of cooling capacities and NEC and CEC.
applications. See AHRI Ratings table. See Indoor Coils Units are UL listed and CSA certified.
and Air Handlers sections for data. ISO 9001 Registered Manufacturing Quality System.
Units shipped completely factory assembled, piped and ENeRCV STaR�certified units are designed to use less
wired. energy, help save money on utility bills, and help protect
Each unit test operated at the factory ensuring proper the environment.
operation. Installer must set air conditioner, connect For expanded ratings, see www.lennoxdavenet.com
refrigerant lines and make electrical connections to
complete job. REFRIGERATION SYSTEM
R-410A Refrigerant
�
Non-chlorine, ozone friendly, R-410A. �:.� � .
Unit pre-charged with refrigerant. See '
Specification table.
XC14-1.5 to b Ton Air Conditioner /Page 2
FEATU RES
REFRIGERATION SYSTEM (CONTINUED)
�High Capacity Liquid Line Drier
DOutdoor Coil Fan
Furnished with unit for fleld installation.
Direct drive fan moves large air volumes uniformly
through entire condenser coil for high refrigerant cooling Approved for use with R-410A systems.
capacity. Traps any moisture or dirt that could contaminate the
Vertical air discharge minimizes operating sounds and refrigerant system.
eliminates damage to lawn and shrubs. �High Pressure Switch
Fan motor has sleeve bearings and is inherently Shuts off unit if abnormal operating conditions cause the
protected. discharge pressure to rise above setting.
Motor totally enclosed for maximum protection from Protects compressor from excessive condensing
weather, dust and corrosion. pressure.
Fan guard constructed of corrosion-resistant PVC Manual reset.
(polyvinyl chtoride)coated steet. oP'noNs
Fan service access accomplished by removal of fan Expansion Valve Kits
guard.
Must be ordered extra and field instatled on certain
e Copper Tube/Enhanced Fin Coil indoor units.
Lennox designed and fabricated coil. See TXV/Orifice Usage table.
Ripple-edged aluminum fins. Chatleff-style fittings.
Copper tube construction. Freezestat
Lanced fins provide maximum exposure of fin surface to Installs on or near the vapor line of the indoor coil or on
air stream resulting in excellent heat transfer. the suction line.
Fin collars grip tubing for maximum contact area. Senses suction line temperature and cycles the
Flared shoulder tubing connections/silver soldering compressor off when suction line temperature falls
construction. below iYs setpoint.
Coil is factory tested under high pressure to ensure Opens at 29°F and closes at 58°F.
leakproof construction. Loss of Charge Switch Kit
Entire coil is accessible for cleaning. Helps protect the compressor from damage due low
Refrigerant Flow Control refrigerant charge conditions.
Units applicable to expansion valve systems or RFC SPST, normally-closed switch, automatic reset switch
systems when matched with specific evaporator coils. mounted on suction tine.
RFCIV METERING SYSTEM Refrigerant Line Kits
RFCIV METERING SYSTEM Refrigerant lines(suction&liquid)are shipped
�IFICE BODY „BU��ET„ refrigeration clean.
(On Coil�ORIFICE
Lines are cleaned, dried, pressurized and sealed at
factory.
LIQUID
O-RING LINE Suction line fully insulated.
O�° LIQUID � Lines are stubbed at both ends.
LINE SCREEN Not available for-060 models and must be field
� s�� fabricated.
NUT SWEAT
CONNECTION
RFCIV:
Accurately meters refrigerant in system.
Refrigerant control is accomplished by exact sizing of
refrigerant metering orifice.
The principle involves matching indoor coil with proper
bore size of orifice in metering device.
Equalizes pressure shortly after compressor stops, unit
starts unloaded, eliminating need for additional controls.
Furnished with air conditioner.
XC14-1.5 to 5 Ton Air Conditioner /Page 3
FEATURES
COMPRESSOR OPTIONS
Scroli Compressor Compressor Crankcase Heater(018 thru 047
Compressor features high models)
efficiency with uniform suction , ,_, Protects against refrigerant migration that can occur
flow, constant discharge flow and �, during low ambient operation.
high volumetric e�ciency and Compressor Hard Start Kit
quiet operation.
Single-phase units are equipped with a PSC
Compressor consists of two �,s compressor motor. This type of motor normally doesn't
involute spiral scrolls matched � . �� need a potential relay and start capacitor.
together to generate a series of
crescent shaped gas pockets In conditions such as low voltage, this kit may be
between them. required to increase the compressor starting torque.
During compression,one scroll Compressor Low Ambient Cut-Off
remains stationary while the other _ Non-adjustable switch (low ambient cut-out) prevents
scroll orbits around it. compresso�operation when outdoor temperature is
Gas is drawn into the outer pocket,the pocket is sealed below 35°F.
as the scroll rotates. CONTRO�S
As the spiral movement continues, gas pockets are o��oNs
pushed to the center of the scrolls. Volume between the �ndoor Blower Off Delay Relay
pockets is simultaneously reduced.
When pocket reaches the center, gas is now at high Delays the indoor blower-off time during the cooling
pressure and is forced out of a port located in the center cycle.
of the fixed scrolls. See AHRI System Matches for usage.
During compression, several pockets are compressed Low Ambient Kit
simultaneously resulting in a smooth continuous Air conditioners operate satisfactorily down to 45°F
compression cycle. outdoor air temperature without any additional controls.
Continuous flank contact, maintained by centrifugal LowAmbient Control Kit can be field installed, allowing
force, minimizes gas leakage and maximizes efficiency. unit operation down to 30°F.
Scroll compressor is tolerant to the effects of slugging Freezestat should be installed on compressors
and contaminants. If this occurs, scrolls separate, equipped with a low ambient kit.
allowing liquid or contaminants to be worked toward the A compressor lock-out thermostat should be added to
center and discharged. terminate compressor operation below recommended
Low gas pulses during compression reduces operation conditions
operational sound levels. Thermostat
Compressor motor is internally protected from Thermostat not furnished with unit. See Thermostat
excessive curcent and temperature. bulletins in Controls Section and Lennox Price Book.
Compressor is installed in the unit on specially Compressor Timed-Off Control
formulated, resilient rubber base for improved sound
dampening and vibration-free operation resulting in Kit prevents compressor short-cycling and allows time
quieter operating sound levels. See Outdoor Sound for suction and discharge pressure to equalize.
Data table for details. Permits compressor start-up in an unloaded condition.
Compressor Crankcase Heater(048 8�060 Models) Automatic reset with 5 minute delay between
Protects against refrigerant migration that can occur compressor shut-off and start-up.
during low ambient operation.
Factory Installed.
Compressor Sound Dampening System
A polyethylene compressor cover containing a 2 inch
thick batt of fiberglass insulation for better sound
dampening.
All open edges are sealed with a one-inch wide hook
and loop fastening tape.
XC14-1.5 to 5 Ton Air Conditioner /Page 4
FEATURES
CABINET
�Heavy-gauge steel construction
Pre-painted cabinet finish.
Painted base section.
Control box is conveniently located with all controls
factory wired.
Corner patch plate allows access to compressor
components.
Drainage holes are provided in base section for
moisture removal.
High density polyethylene unit support feet raise the
unit oTf of the mounting surface, away from damaging
moisture.
SmartHingeTM Louvered Coil Prntr�rtinr,
Steel louvered panels provides
complete coil protection. �k
Panels are hinged to allow easy �
cleaning and servicing of coils. � �
Panels may be completely
removed. .�
Interlocking tabs and slots
assure tight fit on cabinet.
Refrigerant Line Connections, Electrical Inlets and
Service Valves
Suction and liquid lines are located on corner of unit
cabinet and are made with sweat connections.
See dimension drawing.
Fully serviceable brass service valves prevent corrosion
and provide access to refrigerant system. Suction valve
can be fufly shut off,while liquid valve may be front
seated to manage refrigerant charge while servicing
system.
Refrigerant line connections and field wiring inlets are
located in one central area of the cabinet.
See dimension drawing.
XC14-1.5 to 5 Ton Air Conditioner /Page 5
SPECIFICATIONS �
General Model No. XC14-041 4-048 XC14
Data Nominal Tonnage 3.5 3.5 4 4 5
Connections Liquid line(o.d.)-in. 3/8 3/8 3/8 3!8 3/
(sweat) Suction line(o.d.)-in. 7/8 /8 7/8 7/8 1 /8
Refrigerant 'R�10A charge furnished 10 Ibs. 1 oz. Ibs. 0 oz. 11 Ibs.3 oz. 10 Ibs. 0 oz. 12 s. 0 oz.
Outdoor Net face area-sq.ft. Outer coil 21 16. 22 21.00 22.00
Coil Inner coil 20.25 15.7 21.33 20.25 21.33
Tube diameter-in. 5/16 5/16 5l16 5/16 5/16
No.of rows 2 2 2 2 2
Fins per inch 22 22 22 22 22
Outdoor Diameter-in. 22 22 26 22 26
Fan No.of blades 4 4 4 4 4
Motor hp 1/4 1/4 1/3 1/ 1/3
Cfm 3600 3500 400 3 0 4400
Rpm 825 825 25 25 825
Watts 310 310 3 0 310 310
Shipping Data-Ibs.1 pkg. 253 243 28 272 290
ELECTRICALDATA
Line voltage data-60hz 208/230V 08/230V-1ph 208/230 08/230V-1ph 208/230V-1ph
2 Maximum overcurrent protection(amps) 35 40 45 50 60
'Minimum circuit ampacity 22.8 24.1 26.7 29.0 34.8
Compressor Rated load amps 16.7 17.9 19.9 21.8 26.4
Locked rotor amps 79 112 109 117 134
Power factor 0.97 0.94 0. 0.95 0.98
Outdoor Fan Fuil load amps 1.7 1.7 .8 1.7 1.8
Motor Locked rotor amps 3.1 3.1 .9 .1 2.9
OPTIONAL ACCESSORIES- MUST BE ORDERED EXTRA
Compressor Crankcase Heater 93M04 • •
93M06 •
Factory • •
Compressor Hard Start Kit 88M91 • • • • •
Compressor Low Ambient Cut-Off 45F08 • • • • •
Compressor Time-Off Control 47J27 • • • • •
Freezestat 3/8 in.tubing 93G35 • • • • •
5/8 in.tubing 50A93 • • • •
Low Ambient Kit 34M72 • • • • •
Refrigerant L15-65-40 L15-65-40 • • • •
Line Sets L15-65-50
Field Fabricate
Indoor Blower Oif Delay Relay 58M81 • • • • •
NOTE-Extremes of operating range are plus 10%and minus 5%of line voltage,
'Retrigerant charge suffident for 15 ft.length of retrigereM lines.
2 HACR rype breaker or fuse.
'Refer to National w Canadian Electrical Code manual to detertnine wire,fuse and disconned size requiremerns.
XC74-1.5 to 5 Ton Air Conditioner /Page 7
I
OUTDOOR SOUND DATA
Octave Band Sound Power Levels dBA,re 10-1z Watts 'Sound
Center Frequency-HZ Rating
'Unit Number
ModelNo. 125 250 500 1000 2000 4000 8000 dB
XC14-018 52.0 59.5 64.5 65.5 60.5 54.5 45.5 71
XC14-024 55.0 60.0 66.0 66.0 62.5 57.5 47.5 71
XC14-030 55.0 62.0 65.5 66.5 60.0 52.5 45.0 71
XC14-036 53.0 61.0 64.5 65.0 59.5 53.5 48.5 70
'��y XC 14-041 56.5 62.0 68.0 68.5 63.5 56.5 49.5 73 4��
XC14-042 58.5 64.0 68.5 68.5 63.5 56.5 50.5 73
XC14-047 59.5 62.5 67.5 66.0 63.0 57.5 51.5 73
XC 14-048 56.5 62.0 68.0 68.5 63.5 56.5 49.5 73
XC14-060 59.5 62.5 67.5 66.0 63.0 57.5 51.5 73
NOTE-the octave sound power dffia does not indude tonal correction.
'Tested according to AHRI Standard 270-2008 test conditions.
FIELD WIRING
r DISCONNECT 1 r , r DISCONNECT 1
� SWITCH � I T(OpMona)T � I SWITCH I
LSB�OthenLJ L-- --J L�ByOthers) �
q A-Two Wire Power(not furnished)
g p B-Two Power(not furnished).See Electrica�Data
C-Four Wire Low Voltage(not furnished). 18 ga. minimum
D-Five Wire Low Voltage(not furnished). 18 ga.minimum
All wiring must conform to NEC or CEC and local electrical
C codes.
LENNOX LENNOX
AIR HEATING UNIT
CONDITIONER OR
AIR HANDLER
UNIT
INSTALLATION CLEARANCES - INGHES (MM)
See NOTES NOTES:
Service clearance of 30 in.(762 mm)must be maintained on one
of the sides adjacent to the control box.
Clearance to one of the other three sides must be 36 in.(914 mm)
f See � Clearance to one of the remaining two sides may be 12 in.(305
NOTES NOTES mm)and the final side may be 6 in.(152 mm).
�
A clearance of 24 in.(610 mm)must be maintained between two
� units.
See NOTES Control
Box 48 in.(1219 mm)clearance required on top of unit.
XC14-1.5 to 5 Ton Air Conditioner /Page 8
DIMENSIONS - INCHES (MM)
`\_ ,
SUCTION LINE
CONNECTION
(
LIQUID LINE
TOP VIEW CONNECTION
� C — B�
DISCHARGE AIRt
�or,o^ol^o o +°
o!,o�o o�liolo LIQUID LINE ;o
�,000;ioo ��% o
CONNECTION i io
oil�o'�lo 0 0 o i°! 1°
I Qilo I i �
�'000lo° �
�'o 0
�� _
o�o�io��o a ELECTRICAL �a'�
��ol°°�II o A �
� lo o�o o INLETS � I �
o��o o�o o ��
�o�llo o�lli o ✓SUCTION LINE ��°' �
�lo o��,I�o � CONNECTION o� �
°o �I a
o��o oi,o 0
a;oi�o ol��o o / 2(51) � o
�IoVo ouo 0 4-3/4 �
4-1/4(108) �121)
SIDE VIEW � �25� END VIEW
UNIT SUPPORT UNIT SUPPORT
FEET \ FEET \
� O
5-1/2 O O 9-1/2 � 0 �
(2�s) (2a�) K
0 �
8-3/4 8-1/4
(�2) (�) E J
5-1/ 13-1/2 F G H
(140) (343)
XC14-018 BASE SECTION XC14-024 TO-060 BASE SECTION
Model No. , A B C D E F G H J K
in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm
XC14-018 31 787 27 686 28 711 --- --- --- --- --- --- --- --- --- --- --- --- --- ---
XC14-024 35 889 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524
XC14-030 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524
XC14-036 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524
��CC14-041 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524 E�
XC14-042 31 787 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524
XC14-047 35 889 35-1/2 902 39-1/2 1003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683
i
XC14-048 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524
XC14-060 35 889 35-1/2 902 39-1/2 1003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683
XC14-1.5 to 5 Ton Air Conditioner /Page 9
I
TXV/ORIFICE USAGE *TXV SUBSTITUTIONS
Model No. Refrigerant Metering Thermal Indoor Coils/Air Handlers with factory installed expansion
Orifice(RFC) Expansion valves that require field replacement
OMer No. Orifice Size Valve(TXV) Model No. Indoor Coil or Air Order No.
XC14-018 97M74 0.053 37L51 Handler
XC14-024 97M75 0.057 37L51 XC14-030 CBX27UH-036 37L51
�
XC14-030 10W99 0.065 37L51 XC14-036 CX34-31 39L72 I
XC14-036 11W02 0.071 39V2 XC14-036 CX34-36 39V2
���XC14-041 97M77 0.074 91M02 � XC14-036 CX34-38 39L72
XC14-042 97M78 0.076 39L72 XC14-036 CX34-49 39L72
XC14-047 10W86 0.080 91M02 XC14-036 CX34-50l60 39L72
XC14-048 11W07 0.083 91M02 XC14-036 CBX32M-030 39L72
XC14-060 11W11 0.093 91M02
CX34 upflow coils and all Lennox air handlers(except CB26UH"R°)are XC14-036 CBX32M-036 39L72
shipped with a factory installed TXV.In most cases,no change out of the valve XC14-036 CBX32M-042 39L72
is needed.
If a change out is required it will be listed in the"TXV SUBSTITUTIONS°table. XC14-036 CBX32M-048 39L72
The correct TXV must be wdered and fidd installed.C33 coils and all horizon-
tal and downflow coils are shipped without a TXV.The TXV must be ordered XC14-036 CBX32MV-036 39L72
and field installed..
XC14-036 CBX32MV-048 39L72
XC14-036 CBX40UHV-036 39L72
XC14-036 CBX40UHV-048 39L72
XC14-042 CX34-36 39L72
XC14-042 CX34-38 39L72
XC14-042 CBX27UH-048 39L72
XC14-042 CBX32M-036 39V2
XC14-042 CBX32M-042 39L72
XC14-042 CBX32M-048 39L72
XC14-042 CBX32MV-048 39L72
XC14-042 CBX40UHV-048 39V2
XC14-048 CX34�3 91M02
XC14-048 CX34-44/48 91M02
'CX34 coils and all air handlers(except CB28UH"R°)-the factory installed
expansion valve must be replaced with the expansion valve listed(ordered
separately).If the combination is not listed above,the factory installed TXV is
MOST POPULAR MATCHES "�d.
C33 and CH33 coils and CB26UH"R'air handlers-use the RFC shipped with
Outdoor Unit IfldOOf U�It the outdoor unit or replace the factory installed RFC with the expansion valve
Model No. Model No listed in the Thermai Expansion Valves Table.
CR33 and CH23-use the RFC shipped with the outdoor unit or use the expan-
XC 14-018 CX$4-25 sion valve listed in the Thermal Expansion Valves Table.
XC 14-024 CX34-31
XC 14-030 CX34-31
XC 14-036 CX34-38
XC 14-041 CX34-49
XC 14-042 CX34-49
XC 14-047 CX34-62C
XC 14-048 CX34-62C
XC 14-060 CX34-62C
XC14-1.6 to 5 Ton Air Conditioner /Page 10
I
C�LDEK EVAP COOLER Page 1 of 1
A.r■.�=_——
� . �.�– ':=:=
"�///�'_�
CELDEK EVAP COOLER Commerciai Kitcl+e�Ve�t+islion
�s
�rrw�'ee'jrw'
�
n.r..,.
���
EVAP COOLER(CELDEK)
The evaporative cooler module is designed to deliver cool and humidified air in regions with a hot dry
climate. Units are designed for indoor or outdoor installation.
Packages are available in sizes that can handle up to 20,000 CFM. Units have a large access door on the
side to provide access to all electrical components and to facilitate the removal of filters. Standard features
include 12" thick Celdek media. Units consist of a galvanized enclosure with removable 12" media and pre-
piped, pre-wired controls. Units are designed to work on standard water line pressure, and have a built in
moisture control and temperature switch.
To satisfy a variety of installation and climatic requirements units can be joined together in conjunction with
other modules, which include direct fired or indirect fired module and/or blower section. All modules bolt
together to form a rigid common base structure that mount onto a single curb structure.
Operating Principals
On a cali for cooling (when the outside air reaches a level above the built-in thermostat set-point), the
internal solenoid is powered allowing water to flow through the manifold and out through discharge nozzles.
Water leaving the nozzles saturates the face and top of the CELDEK media and eventually soaks the
thickness of the 12" media. A timing circuit controls the Flow of water to the media, thus optimizing the
amount of moisture in the media at all times. While this is occurring, there is continuous airflow through
the CELDEK media, absorbing the moisture in the media.
Benefits of this type of operation are the following:
• No sump or re-cycling pump is required. Because of this, there is less bacterial build-up in the
evaporative cooler and the air being delivered to the space is much healthier.
• There is a continuous wash-down of the media to keep it flushed. This lengthens the life of the
media and �educes service required. This keeps scaling and particle buiid-up minimized.
• There is no sump drain-off required in the winter. Since there is no water reservoir, the concern
about sump freezing is eliminated.
Features
• 12" thick Celdek media
• Pre-wired and pre-piped
• Utilizes standard waterline pressure
• Moisture and temperature control
• Drip-less nozzles
• Pan overflow sensor
http://captiveair.com/catalog/genpartCatalog.asp?lprint=l&catid=266 7/7/2011
�
-r ;_ _
• • . . .
Celdek Evaporative Cooler
Description
The evaporative cooler module is designed to deliver cool and humidified air in regions with a hot, dry climate.
Packages are available in sizes that can handle up to 15,000 CFM. Units are designed for indoor or outdoor
installation. To satisfy a variety of installation and climatic requirements units can be joined together in
conjunction with other modules, which include direct fired or indirect fired module and/or blower section.All
modules bolt together to form a rigid common base structure that mount onto a single curb structure.
Operating Principle
When the outside air reaches a level above the built-in thermostat set point, a call for cooling powers the
internal solenoid; thus, allowing water to flow through the manifold and out through discharge nozzles.Water
leaving the nozzles saturates the face and top of the CELDEK media and eventually soaks the thickness of the
12" media. A timing circuit controls the flow of water to the media, thus optimizing the amount of moisture in the
media at all times.While this is occurring,there is continuous airflow through the CELDEK media; the air
moving across the media absorbs the moisture and delivers the moist,cool air into the space.
Construction
Housing: Unit housing shall be constructed of 20 Gauge G-90 galvanized steel. The wall panels and roof panels
shall be fabricated by forming double-standing, self-locking seams that require no additional support. The floor
and wall panels shall be caulked air tight with a silicone caulk.All casing panels shall be attached with sheet
metal screws or rivets. The access door shall provide easy access to electrical controls and to facilitate the
removal of both the media and spray manifold.
Base:The base shall be constructed of galvanized steel for improved rigidity. A 1-1/2"water drain shall be
installed at the center of the base. Equipment legs,for outdoor installations, and hanging cradle, for indoor
installations, are available and will need to be assembled at the site.
Celdek Media:The media is 12"thick and contained within a frame for ease of access and replacement.
Nozzles and Tubing Assembly:Tubing consists of'/z" PVC smooth pipe with drip-less nozzles. Spray manifold '
is designed to saturate cooling media from both the top and front face. Top spray bar nozzles are removable �
with a flow rate of 2 GPH. Front face spray bar nozzles are drip-less and non-removable with a flow rate of 0.6
GPH. If nozzles are replaced, nozzles of the same type as described should be used. Nozzle threads must be
wrapped in Teflon tape to prevent leakage.
Component Description
Timer.�Controls spray timing sequence. Cycle runs continuously between from spray time on and spray time off.
Timer dial settings are based strictly off of CFM requirement and unit housing size.
Thermostat:Energizes cooling circuit when entering air temperature exceeds factory set point of 85 degrees F.
Factory set point is adjustable.
Solenoid Valve:Normally closed valve which is energized when liquid level controller senses dry condition.
Overflow Switch: Normally closed float-switch. Detects clogged drain to prevent water overflow. The switch kills
power to the water solenoid valve if the water level exceeds'/2" in base of unit.
�
� . _
• • . . .
Pressure Switch: Normally closed switch installed upstream of the 2 way water solenoid valve. Prevents units
installed with freeze protection from continually spraying in the event that the 3 way solenoid valve was never ,
installed in the field. '
3 Way Solenoid Valve (if applicable):Installed under the roofline and provided if the Freezestat option is
ordered. Allows gravity-fed drainage in sub-freezing conditions. �
Plumbing Connections I
P-Trap Hardware and Drain: Drain is installed underneath the module. Hardware for the P-Trap is provided with
the unit and should be attached to the drain. This is a field plumbing connection.
Typical Celdek Submittal Drawing
CELDIX EYAPORATIVE COOLER IHTAKE ,�„� ¢,6,�,
NOTE:
1.) NAX. WATER PRESSIJRE
SO P51 O 70 DEG F
° MAIN RAILS INCLUDED
ON t10DULAR UNITS ONLY
DIM 'B'
DIM 'F"�DIM 'G°� �DIN 'A'� DIM 'L' �DIM 'K'
- -�
� �
DIM 'H' ' ^�RnOV DIN 'D' DIN 'M'
� �
DIM 'C' '��..
*'y;i '
DIM 'J' . DIM •E, DIN 'N' ..
�•DIM 'S' �D[M 'T' DIM� �DIN �1-1/2' �
'R' p. VATER
�1/Z" f�T WATER INIET DRAIN
Im➢EL WEIGNT A B C D E F G H J K L X N P R S T
_ ,C I-01 13 ' ' _ ' ' ' _ _ _ ' ' ' _
�
C I-0i LBS ' - - ' ' ' ' - - ' ' �-V2 5-3/
AL�iIIMENSIDNS ARE NOMINAL AND GIVEN[N INCFES.
UNII INFOPMPTIDN
MODEL�➢IA SIZE bIIILT NAX.RPI N1E
CI[-OS 20424•x12• :2 3.9 GFN
�C➢6- • � 6,5 GPH 4---
-0 0'x36'x ' 28 .4 RI
PI-o
➢[ 12. GPH
� E Nl,.i►�4"s.a oN 1��T ?py�C, �
CELDEK EVAPORATIVE COOLER INTAKE
NOTE:
1.) MAX. WATER PRESSURE
50 P51 O 70 OEG. F
° MAIN RAILS INCLUDED
❑N MODULAR UNITS ❑NLY
DIM 'B'
DIM 'F'--�DIM 'G' r-DIM 'A'-� DIM 'L'� �DIM 'K'
�
DIM 'H' AQ�O''' DIM 'D' DIM 'M'
f�
DIM 'C'
O . . .
DIM 'J' . DIM 'E' DIM 'N'
�• DIM 'S' �DIM 'T' DIM�� �DIM �1-1/2' �
'R' p. WATER
�1/2' NPT WATER INLET DRAIN
VA A N
V
-/ 4-
ALL DIMENSI�NS ARE NOMINAL AND GIVEN IN IN(:FIES.
lEDIA SIZE w�t.i�uv Ic�1E
DI-02
Inspection Items for B11-0208 11:46 11/27/2013
Sec Item Id Descri tion A r Re Items Action Inheritable
534 PLAN-FINAL C/O No R 0 No
* 30 BLDG-Framin No R 0 No
* 120 ELEC-Rou h No R 0 No
200 MECH-Rou h No R 0 No
* 190 ELEC-Final No R 0 No
* 390 MECH-Final No R 0 No
* 90 BLDG-Final No R 0 No
Total Rows:7
•'ti�
.yi..
Page 1