HomeMy WebLinkAboutF11-00371� Department of Community Development' r 75 South Frontage F.o : Vail, Colorad ' Tel: 970' � ,' « ; Ott. . i � ' r {: �, Tax: 9 ... - r enlRev ew d� 2 FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: 00 O (Number) (Street) _ (Suite #) Building /Complex Name: V,R �y r0`� c�✓1 Contractor Information: Company: Sliw�es Ftv� 2aks' c Company Address: _�Oa�. '5' -1 UL5bjJ City: - C o ✓1Ak-Lt -- nt �� u � '' tt State: (_ Zip: O« Contact Name: J(_�O t�t ��r GQe�1 Contact Phone: - 7 — L E -Mail _fi a hart lean 6D- WILD - SA - Town of Vail Contract istration No.: Contractor Signature (required) Property Information Parcel #: (For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or visit www.eaglecounty.us /patie) Tenant Name: Owner Name: B l c aL��` iQ +• ��d �c{�ia -{-rte Complete Valuation for Fire Sprinkler Permit: Fire Sprinkler $: 40.1 A Office Use: (� Project #: Building Permit #: 1 t1 il"101) qS Sprinkler Permit #: Lot #: Block # Subdivision: Detailed Description of Work: 1?e lp e -`' -�e_ J reV&ft (use additional sheet if necessary) Detailed Location of Work: Does a Monitored Fire Alarm Exist? Yes No( ) Does a Sprinkler System Exist? Yes No( ) Work Class: New( ) Addition( ) Remodel' Repair( ) Retro -Fit ( ) Other( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family ( ) Commercial-474 Restaurant ( ) Other ( ) Date Received JUL 0 s 2011 TOWN OF VAIL 01- Feb-10 Reim R labi 2 A complete line of UL Listed and FM Approved quick response extended coverage sprinklers for light hazard applications. Horizontal Sidewall Sprinklers are approved for installation 4" to 12" (102mm - 305mm) Model F1 FR56 QREC Sprinkler Types Pendent Horizontal Sidewall EC -8 Model F1 FR56 QREC Recessed Sprinkler Types Recessed Extended Coverage Pendent F1 /F2 /FP Recessed Extended coverage Horizontal Sidewall Model F1 FR56 QREC Concealed Extended Coverage Pendent Approval Organizations 1. Listed by Underwriters Laboratories, Inc. and Certified for Canada (cULus) 2. Factory Mutual Approvals (FM) UL Listing Category Sprinklers, Automatic & Open Quick Response Extended Coverage Sprinkler (VNIV) Product Description Reliable Models F1FR56 QREC and F1FR56 QREC Re- cessed Sprinklers are quick response sprinklers which combine the durability for a standard sprinkler with the at- tractive low profile of a decorative sprinkler. The Models F1 FR56 QREC and F1 FR56 QREC Recessed Automatic Sprinklers utilize a 3.Omm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five times faster than standard response sprinklers. This quick response enables these sprinklers to apply water to a fire much faster than stan- dard sprinklers of the same temperature rating. Model F1 FR56 QREC Quick Response Extended Cover- age Concealed Sprinkler is an attractive, low profile con- cealed sprinkler assembly. This sprinkler assembly uti- lizes a Model F1 FR56 QREC pendent sprinkler in a Model CCP cup and push -on thread -off cover plate assembly. The cup is securely factory threaded on the sprinkler's in- let end. The assembly is shipped with a protective cap. The sprinkler and cup are easily installed into the sprinkler fitting using the Model RC1 Sprinkler Wrench. The cover plate assembly is attached to the sprinkler cup using a flexible tooth threaded engagement. The cover plate is attached to the skirt using 135 °F (57 °C) ordinary tempera- ture classification solder. Bulletin 028 Rev. A CD W c Model F1 FR Series. Quick Response co Extended Coverage Spray D Extended Coverage Pendent Extended Coverage Pendent Concealed Extended Coverage Horizontal Sidewall EC -8 When the ceiling temperature rises, the solder holding the cover plate melts, allowing the release of this part and thus exposing the Model F1 FR56 QREC sprinkler inside to the rising ambient temperature. The Temperature rating of the sprinkler identified by the color of the glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a pre- cisely manufactured glass capsule. This glass bulb is spe- cially constructed to provide fast thermal response. Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exer- cised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the ap- proving authority having jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Recessed Extended Coverage Pendent F1/F2 Recessed Extended Coverage Horizontal Sidewall EC -8 Model F1 FR56 Quick Response Extended Coverage Pendent Sprinkle) Deflector: EC Installation Wrench: Model D Sprinkler Wrench Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy Installa ' D t Nominal Orifice '12" (15m n) tlon a a. Pressure Max. Area Temperature Sprinkler Thread "K" Factor Sprinkler Approval Rating Identification Size Length Organizations Numbers (SIN) 4.9 x 4.9 33 O F oc 18 x 18 US Metric 151.4 51.0 (3,5) 20 x 20 6.0 x 6.0 1 12" NPT 5.6 80 2.25" (57mm) 1 135 155 57 68 RA2845 (R1/2) 1 135 155 57 68 RA2845 (15mm) (R1/2) T�LI� 4 Coverage Area Flow Pressure Max. Area Rate psi (bar) Width x Length gpm L/min K =5.6 (80) ft. x ft. m x m 26 98.4 21.6 (1,5) 16 x 16 4.9 x 4.9 33 125.0 34.7 (2,4) 18 x 18 5.5 x 5.5 40 151.4 51.0 (3,5) 20 x 20 6.0 x 6.0 (1) 135 (57 only. Model F1 FR56 Recessed Quick Response Extended Coverage Pendent Sprinkler Deflector: EC Installation Wrench: Model GFR2 Sprinkler Wrench Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy 1--- a. —n_a: r1.. +.. (1) See table 1 for Coverage Area. 2 1/4" HOLE DIA. [57. 15mm] 1 15116" DIA [49.21mm] 1 X 3/4" REDUCER TURN COLLAR OR UNTIL TIGHT 1' X 112" REDUCER AGAINST SPRINKLER WRENCH BOSS (— FACE OF FITTING TO (2) ADJUSTMENT CEILING DIMENS (IK2) [3. 1Bmm] (2) i1" 2 27132 DIA. 028FGO iA [72.23mm] Model F1 FR56 QREC F1 /F2 Fig. I (') When installed directly into a tee, the escutcheon adjustment will be reduced. (2) Refer to escutcheon data table for approvals and dimensions. 2 518" 041. [66.7mm] HOLE IN CEILING Temperature Sprinkler Nominal Thread "K" Factor Sprinkler Approval Rating Identification Orifice Size Length Organizations Numbers (SIN) of oC 1 " X 112" REDUCER US Metric \ I I Y2" 1 h" NPT 5.6 80 2.25" 1 135 155 57 68 RA2845 (15mm) (R1/2) TO FACE OF CEILING (57mm) DIMENSION (1) See table 1 for Coverage Area. 2 1/4" HOLE DIA. [57. 15mm] 1 15116" DIA [49.21mm] 1 X 3/4" REDUCER TURN COLLAR OR UNTIL TIGHT 1' X 112" REDUCER AGAINST SPRINKLER WRENCH BOSS (— FACE OF FITTING TO (2) ADJUSTMENT CEILING DIMENS (IK2) [3. 1Bmm] (2) i1" 2 27132 DIA. 028FGO iA [72.23mm] Model F1 FR56 QREC F1 /F2 Fig. I (') When installed directly into a tee, the escutcheon adjustment will be reduced. (2) Refer to escutcheon data table for approvals and dimensions. Fig, 2 2. 2 518" 041. [66.7mm] HOLE IN CEILING 2 5116" DIA. [58.7mm] CUP r a I 1 " X 112" REDUCER \ I I CEILING (�� Q FACE OF FITTING TO FACE OF CEILING I LLLLLL�� DIMENSION 1 + (2) ADJUSTMENT I A (2) 018FG07A Model F1 FR56 QREC FP Fig, 2 2. Model F1 FR -56 Quick Response Extended Coverage Horizontal Sidewall Sprinkler Deflector: EC -8 Installation Wrench: Model D Sprinkler Wrench Approval Type: Quick Response Extended Coverage -Light Hazard Occupancy 1.,_ —+nIlnfinn Rata• IIIV �NIIM Nominal Orifice �I VI• �w-w. Thread Size "K" Factor Sprinkler Length Approval Organizations Temperature Rating S Identification Number (SIN) US Metric UL FM 135 °F (57°C) FM ' /z" ' /z" NPT 5.6 80 2'86 1, 2 155 °F (68 °C) RA2865 (15mm) (R 26.6 (1,8) 28.5 (2,0) (73mm) 4 - 12 (102 - 305) 175 °F (79 °C) 33 (125.0) Model F1 FR -56 Recessed Quick Response Extended Coverage Horizontal Sidewall Sprinkler Deflector: EC -8 Installation Wrench: Model GFR2 Sprinkler Wrench Approval Type: Quick Response Extended Coverage -Light Hazard Occupancy Inc +�Il� +inn data• IIIV�MIIM Nominal Orifice ••v•• �w Thread Size -w. "K" Factor Sprinkler Length Approval( Organizations Temperature "� Rating Sprinkler Identification Number (SIN) US Metric UL FM 135 °F (57 °C) FM /z" Y2" NPT 5.6 80 2'86 1, 2 155 °F (68 °C) RA2865 (15mm) (R 112) 26.6 (1,8) 28.5 (2,0) (73mm) 4 - 12 (102 - 305) 175 °F (79 °C) 33 (125.0) (1) FM Approval of recessed sprinkler - 135 °F (57 °C) only (2) Refer to escutcheon data table for approvals and dimensions. COVERAGE AREA Flow Rate Pressure Maximum Deflector to Ceiling gpm (Umin) psi (bar) Coverage Area Width x Length Dimension Min. - Max. UL FM UL FM ft. x ft. (m x m) Inches (mm) 26 (98.4) 26 (98.4) 21.4 (1,5) 21.4 (1,5) 16 x 16 (4.9 x 4.9) 4 - 12 (102 - 305) 29 (109.8) 30 (113.6) 26.6 (1,8) 28.5 (2,0) 16 x 18 (4.9 x 5.5) 4 - 12 (102 - 305) 32 (121.1) 33 (125.0) 32.4 (2,2) 34.5 (2,4) 16 x 20 ( 4.9 x 6.0 1 4 - 12 (102 - 305) OF FlrnNC rD (') FACE CEILING DIMENSION 4" TO 12" TURN SPRING COLLAR UNTIL T/GHT AGA/NSr SPRINKLER WRENCH BOSS. - l 15/76" _ 2 27132' &A. DIA. L LECOMMENDED WALL HOLE 2 1/4" DIAMETER n Model F1 FR56 QREC HSW EC -8 Fig. 3 (2) Refer to escutcheon data table for dimensions. 3. Model F1 FR56 Quick Response Extended Coverage Concealed Pendent Sprinkler Installation Wrench: Model RC1 Sprinkler Wrench Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy Technical Data: Nominal Thread " K" Factor Approval PP Sprinkler Identification Size Model Orifice Size US Metric Organizations Number SIN 1/2" 1/2" 5.6 80 1 RA2845 15mm R1 2 38 °C COVER PLATE - 1/2" NPT F1FR Thread Tem . Ratin Max. Ceiling Bulb Size Model Temp. Color Sprinkler Cover 1/2" NPT F1FR 135 °F 135 °F 100 °F Orange R12 QREC 57 °C 57 °C 38 °C COVER PLATE - 1/2" NPT F1FR 155 °F 135 °C 100 °F Red R12 QREC I 68 °C 57 °C 38 °C Coveracie Area Pressure Max. Enclosure Area Flow Rate p si bar Width x Length ft. x ft. m x m m (um) K=5.6 80 26 (98.4) 21.6 (1,5) 16 x 16 (4.9 x 4.9) 33 (125.0) 34.7 (2,4) 18 x 18 (5.5 x 5.5) 40 151.4 51.0 35 20x20 6.0x6.0 (1) 135 °F (57 °C) Only Note: 1 bar = 100 kPa i" x 112" REDUCING TEE OR ELBOW -� 2 5118" DIA. 2 5116" DIA - HOLE IN CEILING CUP 1 112" MAX. .�� ;L FACE OF FITTING CEILING 5116 MAX. COVER ADJUSTMENT TO FACE OF CEILING f� DIMEN SION ASSEMBLY 3 5116" DIA. CEILING 112" MAX. - 15116" COVER ADJUSTMENT COVER PLATE - ASSEMBLY 3 5/16" DIA. SPRINKLER 1/2" ADJUSTMENT Fig. 4 Installation Aid: A protective cap is included for use during installation. Installation Quick response sprinkler are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1 FR56 Recessed QREC Sprinklers are to be installed as shown. The Model F1 or F2 Escutcheons il- lustrated are the only recessed escutcheons to be used with the Model F1 FR56 EC Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F1 FR56 QREC Sprinklers, use the Model D Sprinkler Wrench. When installing Model F1FR QREC Recessed Pendent or Sidewall Sprinklers, use the Model GFR2 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. 1" x 112" REDUCING TEE OR ELBOW -� r- 2 51 DIA. 2 5116' DIA - HOLE IN CEILING CUP � 1 1/2" MAX. .�� ;L FACE OF FITTING _ TO FACE OF CEILING T :::: DIMENSION CEILING 5116 MAX. COVER ADJUSTMENT 314" COVER PLATE - ASSEMBLY 3 5116" DIA. SPRINKLER 5/16" ADJUSTMENT Fig. 5 Model F1FR56 QREC Concealed Sprinklers use 135 °F (57 °C) or 155 °F (68 °C) Model F1 FR QREC Pendent Sprin- klers with a threaded Model CCP cup which is factory at- tached to the sprinkler. The assembly is completed by the installation of the attractive, low profile, 135 °F (57 °C) rated cover plate assembly. The cover plate and sprinkler cup are joined using a flexible tooth threaded engagement. A choice of two cover plate assemblies provides either 1 12" (13mm) or 5 /8" (8mm) of cover adjustment. Do not install these sprinklers in ceilings which have pos- itive pressure in the space above. The sprinkler cup is factory attached to the Model F1 FR56 QREC Sprinkler. A Teflon* -based thread sealant should be applied to the sprinkler threads only. * DuPont Registered Trademark. 4 After ,a 2 5 /8 (67mm) inch diameter hole is cut in the ceil- ing, the sprinkler is easily installed with the Model RC1 Wrench. When installing a sprinkler, the protective cap is removed and the wrench is positioned into the sprin- kler /cup assembly until the two wrench faces engage the wrenching flats on the Model FlFR56 QREC Sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler /cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate assembly is then pressed into the cup. Final adjustment is made by turning the cover plate until the skirt flange makes full contact with the ceiling surface. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate /cup assemblies are listed only for use with specific sprinklers. The use of any other con- cealed cover plate /cup assembly with the Model FlFR56 QREC Pendent Sprinkler or the use of the Model CCP con- cealed cover plate assembly on any sprinkler with which it is not specifically listed may prevent good fire protection and will void all guarantees, warranties, listings and ap- provals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND, DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Maintenance The Models FlFR56 QREC and FlFR56 QREC Re- cessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammo- nia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non - operation. Escutcheon Data: (1) EC Pendent. (2) EC HSW. Temnprature Rating Sprinkler ( Maximum Face of Fitting Escutcheon Adjustment «p Dimension to Ceiling Model Temperature Tem rature Wail Dimension Max Recessed 1 1 12" (38.1 mm) (1) 3 /16 ' - 15 /,6' F1 Min Recessed 3/4" 19.1 mm (2) 5m - 24mm 57 Max Recessed 1 1 /2" (38.1 mm) (1) 3/16' - 11/16' F2 Min Recessed 1" 25mm (2 5m - 17mm FP Push -0N Max Recessed '/ 18 " (11mm) 1 1 /2" (38.1 mm) Thread off Min Recessed 15 16" 24mm 1" 25mm (1) EC Pendent. (2) EC HSW. Temnprature Rating Finishes (1) Standard Finishes Sprinkler ( Maximum Coverplate Bronze Sprinkler Ambient Bulb Classification Temperature Tem rature Color Special Application Finishes OF o C CF 'C Ordinary 135 57 100 38 Orange Ordinary 155 68 100 38 Red Finishes (1) Standard Finishes Sprinkler ( Escutcheon Coverplate Bronze Brass Chrome Chrome Plated Chrome Plated White White & Black Polyester Coated White Painted Special Application Finishes Sprinkler (2) Escutcheon Coverplate Bright Brass Bright Brass Bright Brass Black Plating Black Plating Black Plating Black Paint Black Paint Black Paint Off White Off White Off White Satin Chrome Satin Chrome (1) Other colors and finishes are available on special order. Consult tactory for details. I (2) FM Approvals limited to Bronze, Bright Brass, Satin Chrome Plated, Black Plated and Polyester Coated. Note: Paint or any other coating applied over the factory finish will void approvals and waranties. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Finish (where applicable) 8. Coverplate Finish (where applicable) 9. Coverplate Finish (where aplicable) 10. Coverplate Adjustment 11. Coverplate Thread Size 12. Coverplate Temperature Rating Note: When Model FlFR56 QREC Recessed sprinklers are ordered, the sprinklers, escutcheons and coverplates are packaged separately. 5. Reliable,,,For C Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Pressure gauges Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Prod uctsmanuf actu red and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Rel , a The Reliable Automatic Sprinkler Co., Inc. ®Recycled ® (800) 431 -1588 Sales Offices Paper (800) 848 -6051 Sales Fax Revision lines indicate updated or new data. (914) 829 -2042 Corporate Offices www.reliablesprinkler.com Internet Address EG Printed in U.S.A 08/10 P/N 9999970388 Rellablia Bulletin 028 Rev. A M C Model F1 FR Series D Quick Response ° c Extended Coverage Spray. D A complete line of UL Listed and FM Approved quick response extended coverage sprinklers for light hazard applications. Horizontal Sidewall Sprinklers are approved for installation 4" to 12" (102mm - 305mm) Model F1 FR56 QREC Sprinkler Types Pendent Horizontal Sidewall EC -8 Model F1 FR56 QREC Recessed Sprinkler Types Recessed Extended Coverage Pendent F1 /F2 /FP Recessed Extended coverage Horizontal Sidewall Model F1 FR56 QREC Concealed Extended Coverage Pendent Approval Organizations 1. Listed by Underwriters Laboratories, Inc. and Certified for Canada (cULus) 2. Factory Mutual Approvals (FM) UL Listing Category Sprinklers, Automatic & Open Quick Response Extended Coverage Sprinkler (VNIV) Product Description Reliable Models F1 FR56 QREC and F1 FR56 QREC Re- cessed Sprinklers are quick response sprinklers which combine the durability for a standard sprinkler with the at- tractive low profile of a decorative sprinkler. The Models F1 FR56 QREC and F1 FR56 QREC Recessed Automatic Sprinklers utilize a 3.Omm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five times faster than standard response sprinklers. This quick response enables these sprinklers to apply water to a fire much faster than stan- dard sprinklers of the same temperature rating. Model F1 FR56 QREC Quick Response Extended Cover- age Concealed Sprinkler is an attractive, low profile con- cealed sprinkler assembly. This sprinkler assembly uti- lizes a Model F1 FR56 QREC pendent sprinkler in a Model CCP cup and push -on thread -off cover plate assembly. The cup is securely factory threaded on the sprinkler's in- let end. The assembly is shipped with a protective cap. The sprinkler and cup are easily installed into the sprinkler fitting using the Model RC1 Sprinkler Wrench. The cover plate assembly is attached to the sprinkler cup using a flexible tooth threaded engagement. The cover plate is attached to the skirt using 135 °F (57 °C) ordinary tempera- ture classification solder. Extended Coverage Recessed Extended Pendent Coverage Pendent F1/F2 Extended Coverage Extended Coverage Pendent Concealed Horizontal Sidewall EC -8 When the ceiling temperature rises, the solder holding the cover plate melts, allowing the release of this part and thus exposing the Model F1 FR56 QREC sprinkler inside to the rising ambient temperature. The Temperature rating of the sprinkler identified by the color of the glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a pre- cisely manufactured glass capsule. This glass bulb is spe- cially constructed to provide fast thermal response. Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exer- cised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the ap- proving authority having jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Recessed Extended Coverage Horizontal Sidewall EC -8 Model F1 FR56 Quick Response Extended Coverage Pendent Sprinkle Deflector: EC Installation Wrench: Model D Sprinkler Wrench Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy n _ 1 1110 G1 1Q 1 11 vwaw. Pressure Max. Area Rate Temperature Sprinkler Nominal Thread "K" Factor Sprinkler Approval Rating Identification Orifice Size Length Organizations Numbers (SIN) 34.7 (2,4) 18 x 18 of oC 151.4 51.0 (3,5) US Metric 1 /2" 1 12" NPT 5.6 80 225" 1 135 155 57 68 RA2845 (15mm) (131/2) (57mm) 'r-ki– 1 Coverage Area Flow Pressure Max. Area Rate psi (bar) Width x Length gpm L/min K =5.6 (80) ft. x ft. m x m 26 98.4 21.6 (1,5) 16x16 4.9x4.9 33 125.0 34.7 (2,4) 18 x 18 5.5 x 5.5 40 151.4 51.0 (3,5) 20 x 20 6.0 x 6.0 (1) 135 °F (57 °C) only. Model F1 FR56 Recessed Quick Response Extended Coverage Pendent Sprinkler Deflector: EC Installation Wrench: Model GFR2 Sprinkler Wrench Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy IIIJawIIw aIV1• rw�v• Temperature Sprinkler Nominal Thread "K" Factor Sprinkler Approval Rating Identification Orifice Size Length Organizations Numbers (SIN) of oC US Metric 1 /2" 1 /2 " NPT 5.6 80 2.25" 1 135 155 57 68 RA2845 (15mm) (R1/2) (57mm) (1) See table 1 for Coverage Area. 2 114' HOLE DIA. [57. 15mm] 1 15/16' DIA [49.21 mm] 1' X 3/4" REDUCER TURN COLLAR T OR UNTIL TIGHT I I' X 1/2' REDUCER AGAINST SPRINKLER WRENCH BOSS r \ – I FACE OF FITTING TO CEILING DIMENSION (2) vii 1/8 (IK21 (3. 18mm] ADJUSTMENT (2) ii ' 2 27132 DIA. [72.23mm] 028FGO IA Model F1 FR56 QREC F1 /F2 Fig. 1 (1) When installed directly into a tee, the escutcheon adjustment will be reduced. ( 2) Refer to escutcheon data table for approvals and dimensions. 2 516' DIA. [66.7mm] HOLE IN CEILING 2 5116' DIA. [56-7m-] CUP I r_� — � I � � � I \ I I r� 1' X 1/2' REDUCER CEILING T (2J J FACE OF nMNG TO FACE OF CEILING DIMENSION 1 (2) (2) I A ADJUSTMENT 02dFC07A Model F1 FR56 QREC FP Fig 2 2. Model F1 FR -56 Quick Response Extended Coverage Horizontal Sidewall Sprinkler Deflector: EC -8 Installation Wrench: Model D Sprinkler Wrench Approval Type: Quick Response Extended Coverage -Light Hazard Occupancy Installation Data: " Sprinkler al Thread Sprinkler Approval Temperature Identification Orifice Size US Length Organizations Rating Nu mber (SIN) 135'F (57°C) 1 /2" /2 NPT 2.86" 1,2 155 °F (68 °C) RA2865 (15mm) (R1/2) 5.6 80 (73mm) 175'F (79 °C) • Model F1 FR -56 Recessed Quick Response Extended Coverage Horizontal Sidewall Sprinkler Deflector: EC -8 Installation Wrench: Model GFR2 Sprinkler Wrench Approval Type: Quick Response Extended Coverage -Light Hazard Occupancy r,_/<_ ulsl�tuauv�� •.Q•u. Min. - Max. ft. x ft. (m x m) Inches (mm) Sprinkler Nominal Thread "K" Factor Sprinkler Approval (2) Temperature �,� Identification US Metric Orifice Size Length Organizations Rating Number (SIN) 135 °F (57 °C) 1 /2" 1 12" NPT 5.6 80 2.86" 1,2 155 °F (68 °C) RA2865 05mm) (RY2) (73mm) 175 °F (79 °C) (') FM Approval of recessed sprinkler - 135 °1- tbl'U) onq ( Refer to escutcheon data table for approvals and dimensions. Flow Rate gpm (Umin) UL FM COVERAGE AREA Pressure Maximum Deflector to Ceiling psi (bar) Coverage Area Dimension UL 26 (98.4) 26 (98.4) 21.4 (1,5) 29 (109.8) 30 (113.6) 26.6 (1,8) 32 (121.1) 33 (125.0) 32.4 (2,2) FACE OF FITTING TO (2) CEILING DIMENSION F -M =\\ � 4" TO 12' TURN SPRING COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. 2 17131' DIA. 115/16" DO. +1 L IL -+ L RECOMMENDED WALL L HOLE L 1 1 H DIAMETER ADJUSTMENT (2) Model F1 FR56 QREC HSW EC -8 Fig. 3 (2) Refer to escutcheon data table for dimensions. 3. 028FCO3 x Length Min. - Max. ft. x ft. (m x m) Inches (mm) 9(2,, Width 16 x 16 (4.9 x 4.9) 4 - 12 (102 - 305) 16 x 18 (4.9 x 5.5) 4 - 12 (102 - 305) 4) 16 x 20 ( 4.9 x 6.0 4 - 12 (102 30 5) FACE OF FITTING TO (2) CEILING DIMENSION F -M =\\ � 4" TO 12' TURN SPRING COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. 2 17131' DIA. 115/16" DO. +1 L IL -+ L RECOMMENDED WALL L HOLE L 1 1 H DIAMETER ADJUSTMENT (2) Model F1 FR56 QREC HSW EC -8 Fig. 3 (2) Refer to escutcheon data table for dimensions. 3. 028FCO3 Model F1 FR56 Quick Response Extended Coverage Concealed Pendent Sprinkler Installation Wrench: Model RC1 Sprinkler Wrench Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy Tpr_hnical Data: Nominal Thread "K" Factor Approval Pp Sprinkler Identification Size Model Orifice Size US Metric Organizations Number SIN 1/2" 1/2" 5.6 80 1 RA2845 15mm R1 2 38'C COVER PLATE — 1/2" NPT F1FR Thread Temp Rating Max. Ceiling Bulb Size Model Temp. Color Sprinkler Cover 1/2" NPT F1FR 135 °F 135 °F 100 °F Orange R12 QREC 57 °C 57'C 38'C COVER PLATE — 1/2" NPT F1FR 155 °F 135 °C 100 °F Red R12 QREC 68 °C 57°C 38 °C Coverage Area Pressure Max. Enclosure Area Flow Rate p si bar Width x Length ft. x ft. m x m m Vm K =5.6 80 26 (98.4) 21.6 (1,5) 16 x 16 (4.9 x 4.9) 33 (125.0) 34.7 (2,4) 18 x 18 (5.5 x 5.5) 40 151.4 51.0 35 20x20'I 6.0x6.0 "I (1) 135 °F (57 °C) Only Note: 1 bar = 100 kPa 1" x 112" REDUCING TEE OR ELBOW 2 518" DIA. 2 5116" DIA — HOLE IN CEILING J CUP - -- T 1 1/2" MAX. A FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING 1/2" MAX. COVER ADJUSTMENT COVER PLATE — ASSEMBLY 3 5/16" DIA. SPRINKLER —� 1/2" ADJUSTMENT awrm Fig. 4 I' x 112" REDUCING TEE OR ELBOW - r - 2 5/8" DIA. 2 5116" D41A HOLE IN CEILING CUP 1 112" MAX. FACE OF FITTING _ ._ . TO FACE OF CEILING 7.: :�i ON CEILING 5/16" MAX. 3/4" COVER ADJUSTMEN PLATE ASSEMBLY 3 5116" DIA. SPRINKLER —� 5/16" ADJUSTMENT nwma Fig. 5 Installation Aid: A protective cap is included for use during installation. Installation Quick response sprinkler are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1 FR56 Recessed QREC Sprinklers are to be installed as shown. The Model F1 or F2 Escutcheons il- lustrated are the only recessed escutcheons to be used with the Model F1 FR56 EC Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F1FR56 QREC Sprinklers, use the Model D Sprinkler Wrench. When installing Model F1FR QREC Recessed Pendent or Sidewall Sprinklers, use the Model GFR2 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Model F1 FR56 QREC Concealed Sprinklers use 135 °F (57 °C) or 155 °F (68 °C) Model F1 FR QREC Pendent Sprin- klers with a threaded Model CCP cup which is factory at- tached to the sprinkler. The assembly is completed by the installation of the attractive, low profile, 135 °F (57 °C) rated cover plate assembly. The cover plate and sprinkler cup are joined using a flexible tooth threaded engagement. A choice of two cover plate assemblies provides either 1 12 " (13mm) or 5 /8 " (8mm) of cover adjustment. Do not install these sprinklers in ceilings which have pos- itive pressure in the space above. The sprinkler cup is factory attached to the Model F1 FR56 QREC Sprinkler. A Teflon" -based thread sealant should be applied to the sprinkler threads only. ' DuPont Registered Trademark. 4. After a 2 5 /8 (67mm) inch diameter hole is cut in the ceil- ing, the sprinkler is easily installed with the Model RC1 Wrench. When installing a sprinkler, the protective cap is removed and the wrench is positioned into the sprin- kler /cup assembly until the two wrench faces engage the wrenching flats on the Model F1FR56 QREC Sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler /cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate assembly is then pressed into the cup. Final adjustment is made by turning the cover plate until the skirt flange makes full contact with the ceiling surface. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate /cup assemblies are listed only for use with specific sprinklers. The use of any other con- cealed cover plate /cup assembly with the Model F1 FR56 QREC Pendent Sprinkler or the use of the Model CCP con- cealed cover plate assembly on any sprinkler with which it is not specifically listed may prevent good fire protection and will void all guarantees, warranties, listings and ap- provals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Maintenance The Models F1 FR56 QREC and F1 FR56 QREC Re- cessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammo- nia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non - operation. Escutcheon Data: (1) EC Pendent. (2) EC HSW, Temperature Rating Classification Sprinkler Temperature Maximum Ambient Tem rature Face of Fitting Escutcheon Adjustment « to Ceiling Model Ordinary Ordinary Dimension Wall Dimension 100 38 1 100 38 Max Recessed 1 1 /2" (38.1 mm) (') 3 - 15 / 1 s ' F1 Min Recessed 3 /4" 19.1 mm c2i 5m - 24mm Bright Brass Max Recessed 1 (38.1 mm) (') 3 /15 " - 11 /15 " F2 Min Recessed I 1" 25mm c2> 5m - 17mm FP Push -on/ Max Recessed 1 /16" (11 mm) 1 1 1 /2" (38.1 mm) Thread -off Min Recessed 15 / 1" 25mm (1) EC Pendent. (2) EC HSW, Temperature Rating Classification Sprinkler Temperature Maximum Ambient Tem rature Bulb Color Bronze O F Oc OF OC Chrome Plated Ordinary Ordinary 135 155 57 1v 68 100 38 1 100 38 Orange Red Finishes (1) Standard Finishes Sprinkler (2) Escutcheon Coverplate Bronze Brass Chrome Chrome Plated Chrome Plated White White & Black Polyester Coated White Painted SDecial Application Finishes Sprinkler (Z) Escutcheon Coverplate Bright Brass Bright Brass Bright Brass Black Plating Black Plating Black Plating Black Paint Black Paint Black Paint Off White Off White Off White Satin Chrome I Satin Chrome ( Other colors and finishes are available on special order. Consult factory for details. (2) FM Approvals limited to Bronze, Bright Brass, Satin Chrome Plated, Black Plated and Polyester Coated. Note: Paint or any other coating applied over the factory finish will void approvals and waranties. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Finish (where applicable) 8. Coverplate Finish (where applicable) 9. Coverplate Finish (where aplicable) 10. Coverplate Adjustment 11. Coverplate Thread Size 12. Coverplate Temperature Rating Note: When Model FlFR56 QREC Recessed sprinklers are ordered, the sprinklers, escutcheons and coverplates are packaged separately. 91 Reiiable...For Complete P rotect i o n Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gaugesldentification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. ® Recycled (800) 431 -1588 Sales Offices Paper ' (800) 848 -6051 Sales Fax Revision lines indicate updated or new data. (914) 829 -2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A 08/10 PM 9999970388 CAT,P%I.C' C l 'I co a Copper Fittings n wv..connect W you need is o nm C0 p ....r• rr +.—r r�*wr ax: we , .-- or.1`I�q W.M Wtrw+rwl►+w M krIt- IRA r1 oduct3 .atWnW C rinr.{ rt9 "t [ My SR.rvpa co n.w, ww4m IWO The "New Products" page is a continuously updated showcase for new products by NIBCO. Current highlights include: • Compact Economy Ball Valves • Prepackaged Pneumatic Ball Valves • Circuit Balancing Valves • Flanged Butterfly Valves • Bronze Ball Valve Line Extension • PEXlink- copper fittings for PEX applications • Just Right hot -water circulation device • Carbon /Stainless Steel Ball Valves • Socket Fusion Equipment • TruConnectg fittings for Chem -Aire melco rtner t�ae*;•r...� B . . .......... c r.rt • �rerrtt w.ar ta�q�rre The "Fittings" Homepage at www.nibco.com provides easy access to valuable reference tools. k Key information includes: • Price sheets (PDF & Excel format) —also accessible from home page • Downloadable catalogs (PDF format) • Product drill -down capabilities to categories • Wrot Copper & Cast Bronze Fittings • ABS & PVC Drain, Waste, & Vent • PVC Schedule 40 Fittings & Valves • CPVC CTS Fittings ( 2 N,BC0 N NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH:1.888.446.4226 • FAX: 1.800.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www nihrn rnm ADWV 0304 N NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH:1.888.446.4226 • FAX: 1.800.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www nihrn rnm Cast Copper Alloy Flared Fittings . . . . ............. . .. . ..... 22 -24 Copper Insert Fittings for PEXlink . . . ...... . ... . ...... . .. . . 25 -27 Copper Insert Fittings for Polybutylene ..... . ............... 28 -29 Engineering Data ............. ..........................41 -84 Frequently -Asked Questions ..... . . ... . .. . . .... . ... . .. . ... . . . 90 Installation Instructions ... ............................... 85 -89 Numerical Index ............. .............................92 Specifications ............... ..............................4 Warranty ................... .............................91 Wrot & Cast DWV Fittings ............................... 30 -40 Wrot & Cast Pressure Fittings ............................. 5 -21 1509001:2000 The manufacturing plants at South Glens Falls, NY, Stuarts Draft, V& Nacogdoches, TX and Reynosa, Mexico manufacture products under a Quality Management System conforming to the anent revision of ISO -9001 International Standards NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 SpecifiIM cations All of the advantages found in copper as a metal have been capitalized to the utmost in the manufacture of NIBCO Fittings. Because of the accuracy of construction and design, copper plumbing is more efficient and less expensive. NIBCO manufactures nine general types of fittings: Wrot Pressure; Cast Pressure; Wrot Drainage; Cast Drainage; Flanges; Flared Tube; Threaded Bronze; Insert Fittings for PEX; Barbed Insert Fittings for Polybutylene. Each has its particular place and use and each offers its own advantages when used for the proper service requirement. ALLOY AND FINISH — NIBCO Fittings are made from highest quality raw materials available — Cast Fittings are made from Copper Alloy C84400 which consists of 81% Copper, 7% Lead, 3% Tin, and 9% Zinc per ASTM Specification B584. Wrot Copper Fittings are made from commercially pure copper mill products per ASTM Specifications B75 Alloy C12200. NIBCO fittings are produced to meet requirements of applicable standards wherever practicable. NIBCO brand wrot and cast fittings are manufactured in the U.S.A. and Mexico. The manufacturing plants at South Glens Falls, NY, Stuarts Draft, VA, Nacogdoches, TX and Reynosa, Mexico are registered to ISO 9002 quality standards. Following is suggested phrasing to be incorporated in your specifications or bills of material for Copper Tube Fittings. WROT SOLDER JOINT FITTINGS — "Wrot Solder Joint Fittings shall be produced to one of the following specifications: 1. Material and workmanship shall be in accordance with ASME /ANSI 816.22; Wrought Copper and Copper Alloy Solder Joint Pressure Fittings." 2. The dimensional, material and workmanship shall meet the requirements of MSS SP -104; Wrought Copper Solder Joint Pressure Fittings." 3. The dimensional, material and workmanship of 5 " -12" copper fittings shall meet the requirements of MSS SP -109 "Welded Fabricated Copper Solder Joint Pressure Fittings." 4. Certified to ANSI /NSF 61. CAST COPPER ALLOY SOLDER JOINT FITTINGS — "Cast Copper Alloy Solder Joint Fittings shall be in accordance with ANSI Std. 616.18." WROT DRAINAGE FITTINGS — "Wrot Drainage Fittings shall be in accordance with ASME /ANSI Std. 816.29." CAST COPPER ALLOY SOLDER JOINT DRAINAGE FITTINGS — "Cast Copper Alloy Solder Joint Drainage Fittings shall be in accordance with ASME Std. 816.23." CAST COPPER ALLOY FLARED TUBE FITTINGS — "Cast Copper Alloy Flared Tube Fittings shall be in accor- dance with ASME /ANSI Std. 816.26. CAST COPPER ALLOY FLANGES AND FLANGED FITTINGS— CLASS 150 — Cast Copper Alloy Flanges and Flanged Fittings shall meet the requirements of MSS SP -106 and /or the workmanship and dimensions of Federal Specifications WW -F -406 or ASME Std. 816.24. CLASS 125 — Material, workmanship and dimensions of flanges shall be in accordance with MSS SP -106. CAST BRONZE THREADED FITTINGS — "Cast Bronze Threaded Fittings shall be in accordance with ANSI /ASME 816.15." POLYBUTYLENE COPPER INSERT TYPE VALVES AND FITTINGS — "Wrot Copper Insert Fittings shall be manufactured per the following specifications: MSS SP -103 or ASTM F1380." NIBCO Copper Tube Fittings are all produced to above Standards. To simplify, write your specifications to read: "Copper Tube Fittings to be in accordance with specifications as outlined in NIBCO Catalog c -cf- 0602." WROT COPPER MEDICAL MEDICAL GAS SYSTEM COMPONENTS — Wrot copper fittings that are to be installed in medical gas applications shall be prepared in accordance with NFPA 99, Health Care Facilities Gas and Vacuum Systems and the Compressed Gas Association, Pamphlet G4.1. Packaging shall be adequately protective and include labeling that identifies the preparer and states that the product has been cleaned and bagged for oxygen or med gas service. For technical information and dimensions refer to the engineering section contained in this catalog. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Wro and Cast Pres Fi 600 Series — Wrot 700 Series — Cast Adapters................... ............................6 -8 Air Chambers ............... ..............................8 Bulkhead Fittings ............ ..............................8 Bushings ................... ..............................8 Caps...................... ..............................9 Couplings ................... ...........................9 -11 Crosses .................... .............................11 Elbows ..................... ..........................11 -15 Fitting Reducers ............. .............................15 Flanges .................... ..........................15 -16 Plugs ...................... .............................16 Return Bends ............... .............................16 Straps ..................... .............................16 Tees....................... ..........................16 -20 Traps...................... .............................20 Unions..................... .............................21 Venturi..................... .............................21 Y's ........................ .............................21 iso�oot:xooa The mardacturirg plants at South Glens Falls, NY, Stuarts Draft, VA, Nacogdoches. TX and Rerm, Mexico manufacture products under a Quality Management System conforming to the current revision of ISO -9001 International Standards NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 ADAPTERS 603 Adapter C x F - Wrot NOM. SIZE 1/8 A�1' NET WT./LBS. 0.03 , , INCHES 13 /32 1/8 x 1/4 0.03 '12 1/4 0.03 5 /8 1/4 x 3/8 0.05 21 /32 3/8 0.04 11 /16 3/8 x 1/2 0.09 29 /32 3/8 x 1/4 0.03 9 /16 112 0.09 21 /32 112 x 3/4 0.14 1 112 x 3/8 0.04 17 /32 112 x 1/4 0.05 1 /2 5/8 x 3/4 0.12 29 /32 5/8 x 112 0.11 3 /4 3/4 0.15 29 /32 3/4 x 1 0.21 1 3/4 x 112 0.10 5 /8 1 0.24 31 /32 1 x 11/4 0.28 1 1 x 3/4 0.19 25 /32 1 x 112 0.24 5 /8 1 1/4 0.33 1 1 1/4 x 1 112 0.40 1 1 1/4 x 1 0.27 31 /32 11/2 0.44 1 /8 1 112 x 2 0.50 1 2 0.63 1 2 x 1112 0.74 1 21/2 1.13 - 3 1.94 - 703 Adapter C x F - Cast NOM. SIZE 1/4 x 112 NET WT./LBS. 0.13 1 , INCHES 27 /32 1/2 x 1 0.30 1 3/4 x 1 1/4 0.55 1'/8 3/4 x 3/8 0.17 3 /4 1 x 1112 0.68 13 /32 1 1/4 x 1 0.27 31 /32 1 1/4 x 3/4 0.29 3 /4 1 112 x 2 0.78 1'/32 1 1/2 x 1 0.37 25 /32 1 112 x 1 1/4 0.47 1 2 x 11/4 0.76 27 /32 2112 1.62 1 3 2.34 1 4 4.05 1 D 603 -2 Fitting Adapter Ftg x F - Wrot 1/4 0.03 1 3/8 0.06 1 112 0.09 1 112 x 3/8 0.05 1'/4 3/4 0.13 1 1 0.27 2 1 1/4 0.31 2 1 112 0.43 2 2 0.61 2 703 -2 Fitting Adapter Ftg x F - Cast APPROX. DIM. B NOM. SIZE NET VVT.ILBS. INCHES 112 x 1/4 0.11 1 3/4 x 112 0.12 1 1 x 3/4 0.38 1 1 x 112 0.15 1 21/2 1.65 2 3 2.47 3 703 -5 Special Drop Adapter C x F - Cast APP , NOM. SIZE NET WT./LBS. INCHES 112 0.16 3 /4 3/4 0.24 31 /32 ip 7 03-5 B Drop Adap APPROX. DIM. A NOM. SIZE NET WT. /LBS. INCHES 1 Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 ADAPTERS continued III 604 Adapter C x M - Wrot 704 Adapter C x M - Cast NOM. SIZE 1 /8 x 1 /4 APPR41A. NET WT./LBS. 0.03 DIM. INCHES 7 /16 1/4 0.03 23 /32 3/8 0.04 15 /32 3/8 x 3/4 0.15 1 5 /16 3/8 x 112 0.09 1 112 0.07 5 /8 112 x 1 0.25 1 1 12 112 x 3/4 0.15 13 /16 112 x 3/8 0.05 19 /32 112 x 1/4 0.07 5 /a 5/8 x 3/4 0.16 1 1 /8 5/8 x 112 0.08 3 /4 3/4 0.14 13 /16 3/4 x 1 0.26 1 7 /16 3/4 x 112 0.10 27 /32 1 0.21 31 /32 1 x 1112 0.54 29 /32 1 x 11/4 0.38 1 1 12 1 x 3/4 0.18 29 /32 1 x 112 0.18 31 /32 1 1/4 0.35 15 /16 1 1/4 x 1 112 0.51 1 19 /32 1 1/4 x 1 0.27 1 5 /32 11/2 0.44 31 /32 1 1/2 x 2 0.81 1 1 /8 1 1/2 x 1 1/4 0.38 1 3 /16 1 112 x 1 0.37 1 3 /32 2 0.81 1 3 /32 2 x 1112 0.64 1 1 /8 21/2 1.48 1 21 /32 3 1.69 - Consult price sheet for Made to Order items and for minimum order quantities. N SIZE 3/4 x 11/2 NET VVT./LBS. 0.60 INCHES 1 1 '/32 3/4 x 11/4 0.38 1 7 /32 3/4 x 3/8 0.19 13 /16 1x2 1.15 - 1 x 1 1/2 0.64 29 /32 1 1/4 x 2 0.88 1 9 /32 1 1/4 x 3/4 0.30 31 /32 1 112 x 2 0.77 1 1 /8 2 x 21 12 1.57 1 15 /32 2 x 1112 0.71 1 1 /8 2x11/4 1.08 - 21 12 1.48 1 21 /32 21 12 x 2 1.83 1 11 /16 3 1.96 1 1 /2 4 3.66 1 11 /16 5 8.60 2 5 /8 6 10.73 2 14 A dapter Flush • APPROX. DIM. B NOM. SIZE NET WT. /LBS. INCHES 11 3/4 0.03 19 /32 14 H ose Adapter / APPROX. DIM. A NOM. SIZE NET WT. /LBS. INCHES 0.09 NOTE: Fits 1 1z," s /e" and 3 /4" Garden Hose. M 604 -2 Fitting Adapter Ftg x M - Wrot NOM. SIZE 1/8 APPRIVA. NET WT./LBS. 0.02 1 INCHES 1 1 /8 3/8 0.04 1 1 /4 112 0.09 1 15 /32 112 x 3/4 0.16 1 13 /16 112 x 3/8 0.04 1 11 /32 3/4 0.17 1 15 /16 1 0.25 2 1 /4 704 -2 Fitting Adapter Ftg x M - Cast 2112 1.55 3 3 /8 3 2.21 3 23 /32 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1574.295.3221 • FAX: +1.574195.3455 Aht'&*A. 11M. NOM. SIZE NET VVT./L13S. INCHES 3/4 x 1 0.27 1 31 /32 3/4 x 112 0.12 1 23 /32 1 x 3/4 0.24 1 15 /16 11/4 0.43 2 27 /32 1112 0.54 2 13 /32 2 0.89 2 3 /4 2112 1.55 3 3 /8 3 2.21 3 23 /32 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1574.295.3221 • FAX: +1.574195.3455 ADAPTERS continued r 6 k 704 -2 -H Hose Adapter Ftg x Hose -Cast APPR 1 1 3/4 F x 112 H 0.16 1 NOTE: Fits' /i" s /e" and 3 /4" Garden Hose, AIR CHAMBERS I • Cham ber Air 1 APPROX. DIM.A DIM. L N07M SNOM. SIZE NET WT. /LBS. INCHES INCHES 112 x • 1 112 x 12 1 112 x 14 0.78 1 14 3/4 x 12 0.40 1 12 620 -L Air Chamber or Stub -Out Ftg - Wrot As Air Chamber, just solder one joint. When used as Stub -Out, simply pressure test system then cut off stub-out (save piece for future use) and install valve or fixture. APPRUX. DIM. L NOM. SIZE NET WT. /LBS. INCHES 112 x • 1 1/2x8 0.19 8 112 x 10 0.24 10 1/2x12 0.28 12 3/4 x 12 0.46 12 BULKHEAD FITTINGS _� VA- 750 Bulkhead Fitting C x C - Cast APPROX DIM A 1 N SIZE NET VVT./LBS. INCHES INCHES 112 0.48 1'/4 1 3/4 0.77 1 1 1 1.30 1 1 1112 2.87 1 2 2 3.82 2 2 r .0 ■IllliliP 75 0 - 3 Bulkhead APPROX. DIM. A DIM. B NOM. SIZE NET WT. /LBS. INCHES INCHES 0 .48 115/16 1 1 1 1.43 2 1 f =�Illll�lllualll I �illlll�lllllllilll 75 0 - 4 Bulkhead APPROX. DIM. A DIM. B NOM. SIZE NET WT. /LBS. INCHES INCHES 0.40 1 1 1 BUSHINGS .......... L 618 Flush Bushing Ftg x C - Wrot N SIZE 1/4 x 1/8 '• •1 NET VVT./LBS. 0.01 1 . INCHES 1 /16 3/8 x 1/4 0.01 '/16 112 x 3/8 0.02 3 /32 112 x 1/4 0.04 1 /4 5/8 x 112 0.03 '/16 3/4 x 5/8 0.22 3 /16 3/4 x 112 0.08 3 /32 3/4 x 3/8 0.11 '/16 1 x 3/4 0.12 '/8 1 x 112 0.22 15 /32 11/4 x 1 0.17 3 /32 1112 x 1 1/4 0.22 5 /32 2 x 1112 0.66 '/8 I ro B 618 -3 Flush Bushing Ftg x F - Wrot APPR 1 N SIZE NET Wr./LBS. INCHES 112 x 1/8 0.03 9 /16 112 x 1/4 0.03 9 /16 1 x 112 0.13 31 /32 11/4 x 3/4 0.18 1 1112 x 1 0.25 1 Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574195.3221 • FAX: +1.574.295.3455 617 Tube Cap C - Wrot APP NOM. SIZE NET WT 11 Bs 1/8 0.01 '/32 1/4 0.01 3 /32 3/8 0.01 3 /32 112 0.02 3 /32 5/8 0.03 1 /8 3/4 0.04 '/8 1 0.07 5 /32 11/4 0.10 3 /32 1 112 0.16 1 /8 2 0.27 5 /32 2112 0.50 7 /32 3 0.78 7 /32 4 1.66 1 /4 I -N 717 Tube Cap C - Cast APPROX. DIM. N NOM. SIZE NET WTABS. INCHES 5 5.48 The 6 9.07 17 /32 -►I A (+- 717-D Drain Cap - Cast APP NOM. SIZE NET WTABS. INCHES 112 0.06 21 /32 Consult price sheet for Made to Order items and for minimum order quantities. COUPLINGS A �'1 t• 600 Reducing Coupling C x C - Wrot APP NOM. SIZE NET VVT.ILBS. INCHES 1/8 x 3/16 O.D. 0.01 5 /32 5/16 O.D. x 1/8 0.01 3 /16 1/4 x 5/16 O.D. 0.01 3 /16 1/4 x 1/8 0.01 3 /16 3/8 x 1/4 0.02 3 /16 3/8 x 5/16 O.D. 0.01 '/4 3/8 x 1/8 0.01 1 /4 112 x 3/8 0.03 3 /16 112 x 1/4 0.02 1 /4 112 x 1/8 0.03 "/32 5/8 x 112 0.05 3 /16 5/8 x 3/8 0.04 11 /32 5/8 x 1/4 0.03 13 /32 3/4 x 5/8 0.07 3 /16 3/4 x 112 0.06 9 /32 3/4 x 3/8 0.06 3 /8 3/4 x 1/4 0.05 11 /32 1 x 3/4 0.11 11 /32 1 x 5/8 0.09 3 /8 1 x 112 0.10 11 /32 1 x 3/8 0.10 13 /32 1 1/4 x 1 0.16 5 /16 1 1/4 x 3/4 0.18 17 /32 1 1/4 x 5/8 0.18 5 /8 1 1/4 x 112 0.14 7 /16 1 112 x 11/4 0.23 5 /16 1 112 x 1 0.22 9 /16 1 112 x 3/4 0.20 3 /8 1 112 x 112 0.19 '/2 2 x 1112 0.41 9 /16 2 x 11/4 0.35 11 /16 2 x 1 0.37 7 /16 2 x 3/4 0.34 17 /32 2 x 112 0.35 23 /32 21 12 x 2 0.59 9 /16 21/2 x 1 112 0.65 11 /16 21 12 x 1 1/4 0.65 13 /16 21 12 x 1 0.73 29 /32 Continues... NOM. SIZE NET WT./LBS INCHES 3 x 21/2 0.98 '12 3 x 2 1.06 15 /16 3 x 1 112 0.92 1'/32 31/2 x 3 1.52 1 12 4 x 31 12 2.12 19 /32 4 x 3 1.92 27 /32 4x21/2 1.77 1 4 x 2 1.92 1 5 x 4 3.50 3 5 x 3 3.18 1 5 x 21 12 3.50 13 /16 5 x 2 3.09 2 6 x 5 5.70 1 6 x 4 5.24 1 6 x 3 5.04 2 6 x 21/2 5.13 2'/4 6 x 2 4.89 2 8 x 6 13.06 1 8 x 4 12.22 2 8 x 3 11.79 3 8 x 21 12 12.64 3 A* - : ]j �-A 600 -RS Coupling with Rolled Tube Stop CXC - Wrot APP NOM. SIZE NET WT./LBS. INCHES 1/8 OR D. 0.01 1 /16 3/16 0. D. 0.01 3 /32 1/8 0.01 1 /16 5/16 0. D. 0.01 3 /32 1/4 0.01 '/16 3/8 0.01 3 /32 112 0.03 3 /32 5/8 0.04 3 /32 3/4 0.06 3 /32 7/8 0.09 3 /32 1 0.11 3 /32 11/4 0.16 1 /8 11/2 0.23 '/8 2 0.41 1 /8 2112 0.65 1 /8 3 0.93 '/8 31/2 1.45 5 /32 4 1.93 7 /32 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1574.295.3221 • FAX: +1.574.295.3455 COUPL INGS continued T F - 600 -DS Coupling with Dimpled Tube Stop CxC - Wrot NOM. SIZE 3/16 O.D. APP Rilk NET VVT./LBS. 0.01 DIF11 , INCHES 3 /32 1/8 0.01 ' /16 5/16 0. D. 0.01 3 /32 1/4 0.01 ' /16 3/8 0.01 3 /32 112 0.03 3 /32 5/8 0.04 3 /32 3/4 0.06 3 /32 7/8 0.09 3 /32 1 0.11 3 /32 11/4 0.16 1 /8 11/2 0.23 1 /8 2 0.41 1 /8 2112 0.65 1 /8 3 0.93 '/8 31/2 1.45 5 /32 4 1.93 1 /32 5 3.53 7 /32 6 5.63 1 /32 8 14.12 15 /32 601 Coupling without Stop CxC - Wrot APPROX. DIM. B 1 NOM. SIZE NET WT./LBS. INCHES 1/4 0.01 11 /16 3/8 0.01 27 /32 112 0.03 1 5/8 0.04 1 3/4 0.06 1 1 0.11 1 11/4 0.16 2 1 112 0.23 2 2 0.41 2 2112 0.64 2 3 0.86 3 31/2 1.40 3 4 1.84 4 5 3.50 5 6 5.60 6 8 13.68 8 16 D A-►I 701 Reducing Coupling C x C - Cast APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 3 x 11/4 1.35 23 /32 3 x 1 1.64 27 /32 701 -D Drain Coupling C x C - Cast APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 112 0.08 '/4 3/4 0.14 1 /4 1 0.22 '/4 A - +� 702 Eccentric Coupling C x C - Cast i NOM. SIZE NET WT./LBS. INCHES 3/4 x 112 0.10 "/32 1 x 3/4 0.18 'A 11/4 x 1 0.25 'A 11/4 x 3/4 0.24 9 /32 0 G 724 -5 -A Hy -Set Hanger Coupling C - Cast APP NOM. SIZE NETVVT./LBS. INCHES INCHES 112 0.05 1 23 /32 3/4 0.09 1 /8 27 /32 1 0.13 1 /8 1 Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574295.3221 • FAX: +1.574.295.3455 COUPLINGS continued J 736 Cross -Over Coupling CXC - Cast APPROX. 1 NOM. SIZE NET WT./LBS. INCHES 112 0.27 1 7 /16 3/4 0.60 1 29 /32 Consult price sheet for Made to Order items and for minimum order quantities. CROSSES 735 CrossCxCxCxC - Cast NOM. SIZE 3/8 '1' NET WI/LBS. 0.09 1 INCHES 3 /8 112 0.15 7 /16 3/4 0.30 9 /16 1 0.54 23 /32 11/4 0.78 7 /8 1 112 1.05 1 2 2.00 1 1 /4 2112 2.96 1 1 12 ELBOWS E ' to ' qL5 4 Elbow 1 APPROX. DIM. C DIM. D NOM. SIZE NET WT. /LBS. INCHES INCHES 11 1/4 0.02 9 /32 9 /32 3/8 0.03 3 /16 3 /16 112 0.04 9 /32 9 /32 5/8 0,09 15 /32 75 /32 3/4 0.10 11 /32 11 132 7/8 0.20 11 /16 11 /16 1 0.16 3 /8 3 /8 1 1/4 0.25 17 /32 17 /32 11/2 0.35 19 /32 19 /32 2 0.65 25 /32 25 /32 2 112 1.07 29 /32 29 /32 3 1.58 1 1 /8 1 1 /8 4 3.35 1 7 /16 1 7 /16 5 11.05 1 9 /16 1 9 /16 6 16.95 2 2 8 23.00 2 9 132 2 9 /32 AAL 606 -2 45° Fitting Elbow Ftg x C - Wrot 1 1/4 A"A41A. 0.02 DIFTI. 9 /16 1 1 /4 112 0.04 3 /4 7 /32 5/8 0.08 1 1 /8 13 /32 3/4 0.10 1 1 /16 5 /16 1 0.16 1 7 /32 75 /32 11/4 0.25 1 19 /32 17 /32 1 112 0.35 1 25 /32 19 /32 2 0.65 2 3 /16 25 /32 2112 1.07 2 3 /16 29 /32 3 1. 55 2 19 /32 1 5 /32 NIBCO INC. WORLD HEADQUARTERS ' 1516 MIDDLEBURY ST. ^ IN 46516 -4740 • USA ' PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 ' FAX: +1.574.295.3455 ELBOWS continued a� 0. 45' Fitting El APPROX. DIM. B DIM. C NOM. SIZE NET WT. /LBS. INCHES INCHES i 3 607 90° Elbow - Close Rough CXC - Wrot NOM. SIZE NETWT./LBS. 1/8 ,. 0.01 „ INCHES 13 /32 , , , INCHES 13 /32 1/4 0.02 9 /32 9 /32 3/8 0.03 '12 '12 112 0.04 3 /8 3 /8 112 x 3/8 0.04 9 /16 21 /32 3/4 0.10 17 /32 17 /32 3/4 x 5/8 0.12 29 /32 7 /8 3/4 x 112 0.10 17 /32 'A 1 0.21 23 /32 23 /32 1 x 3/4 0.16 23 /32 5 /8 11/4 0.31 1 1 1 1/4 x 1 0.31 1 1' 5 /32 1 112 0.46 1 1 1 112 x 1 1/4 0.35 1 1 2 0.84 1 1 2 x 1 112 0.58 1 1 21 12 1.41 1 1 3 2.07 2 2 31 12 2.94 2 2 4 4.23 2 2 5 7.74 2 2 6 10.95 3 3 8 29.50 4 4 707 90° Elbow - Close Rough CXC - Cast APPROX. DIM. C DIM. D NOM. SIZE NETWT./LBS. INCHES INCHES 11/4 x 1 0.42 1 1 11/4 x 3/4 0.34 9 /16 13 /16 11/4 x 112 0.28 75 /32 2 '/32 1112 x 1 0.54 11 /16 1 1 112 x 3/4 0.42 19 /32 31 /32 1 112 x 112 0.40 5 /8 29 /32 2 x 11/4 0.86 7 /8 1 2 x 1 0.78 3 /4 1 2 x 3/4 0.69 5 /8 1 21 12 x 2 2.16 1 19 /32 3 x 21/2 2.26 1 1 3 x 2 2.68 1 1 4 x 3 5.18 1 2 607 -1 ,...,. NET WT./LBS. 0.01 90° Elbow - INCHES 13 /32 Intermediate Radius C x C - Wrot AP i NOM. SIZE NET WT./LBS. INCHES INCHES 5/16 0. D. 112 0.06 19 /32 19 /32 5/8 0.09 7 /8 7 /8 3/4 0.14 13 /16 3 /16 1 0.24 1 1 607 -LT 90° Elbow - Long Radius CXC - Wrot NOM. SIZE 3/16 0. D. ,...,. NET WT./LBS. 0.01 , INCHES 13 /32 INCHES 13 /32 1/8 0.01 13 /32 13 /32 5/16 0. D. 0.02 9 /16 9 /16 1/4 0.02 17 /32 17 /32 1/4 x 1/8 0.01 79 /32 1 12 3/8 0.04 23 /32 23 /32 112 0.08 '/8 7 /8 112 x 3/8 0.06 13 /16 13 /16 112 x 1/4 0.03 25 /32 21 /32 5/8 0.10 1 1 5/8 x 112 0.09 1 /16 1 3/4 0.16 1 1 3/4 x 5/8 0.13 1 1 3/4 x 112 0.10 1 1 /16 7/8 0.28 1 1 1 0.28 1'/16 1 1 x 3/4 0.20 1' /4 1 1 x 5/8 0.15 1 1 1 1/4 0.42 1 1 1 1/4 x 1 0.33 1 1 11/2 0.66 2'/4 2 2 1.23 2 2 2112 1.96 3 3 3 2.93 4 4 4 5.95 5 5'/4 Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 607 -2 90° Fitting Elbow - Close Rough Ftg x C - Wrot NOM. SIZE 1/4 AiLIPROA. NETWT/LBS. 0.02 INCHES 3 /4 INCHES 3 /8 3/8 0.03 15 /16 '12 112 0.04 31 /32 3 /8 5/8 0.07 1 17 /32 3/4 0.10 1 "/32 17 /32 1 0.20 1 3 /4 27 /32 11/4 0.33 2 1 /8 1 1 112 0.46 2 1 2 0.84 2 1 21 12 1.39 3 1 3 2.10 3 13 /16 2 4 4.00 4 3 /4 2 L •1 •1' Fitting Elbow Intermediate Radius APPROX. DIM. B DIM. C NOM. SIZE NET WT. /LBS. INCHES INCHES 10 5/8 0.09 1 9 /16 7 /8 3/4 0.14 1 13 /16 1 0.24 2 1 1 /16 Consult price sheet for Made to Order items and for minimum order quantities. 607 -2 -LT 90° Fitting Elbow - Long Radius Ftg x C - Wrot NOM. SIZE NETVV'T.ILBS. 1/8 WYLA41A. 0.01 DIM. INCHES 73 /32 , INCHES '12 1/4 0.02 1 3 /4 3/8 0.05 1'/8 7 /8 112 0.08 1 9 /16 1 112 x 3/8 0.06 1 5 /16 13 /16 112 x 1/4 0.03 1 7 /4 5 /8 5/8 0.10 1 1 3/4 0.16 1 15 /16 1 1 0.31 2'12 1 11/4 0.43 2 1 11/2 0.66 2 2 1 /4 1 112 x 11/4 0.50 3 2 2 1.27 4 "/32 2 2112 2.16 5 3 11 /16 3 3.10 5 3 /4 4 1 /32 L L 607 -2 -2 90° Fitting Elbow -Close Rough Ftg x Ftg - Wrot APPROX. NOM. SIZE NET WT./LBS. INCHES 112 0.04 1 1 /16 3/4 0.12 1 3 2.12 3 1112 0.46 2 2 0.82 2 1 0.20 1 11/4 0.33 2'/8 607- 2 -2 -LT 90° Fitting Elbow - Long Radius Ftg x Ftg - Wrot NOM. SIZE 1/4 AstiRktA. NET VVT./LBS. 0.02 . INCHES 27 /32 3/8 0.04 1'/8 112 0.08 1 5/8 0.10 1 "/16 3/4 0.16 1 15 /16 1 0.31 2'12 11/4 0.43 2 11/2 0.65 3 7 /16 2 1.25 4 1 •1• Fitting Elbow APPROX. DIM. B DIM. E NOM. SIZE NET WT. /LBS. INCHES INCHES 1 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 ELBOWS continued ELBOWS continued 707 -3 90° Elbow C x F - Cast 1/4 0.06 13 /32 9 /16 3/8 0.09 1 /16 11 /16 3/8 x 112 0.13 9 /16 13 /16 112 0.12 1 /16 13 /16 112 x 3/4 0.18 11 /16 15 /16 112 x 3/8 0.09 1 12 13 /16 112 x 1/4 0.10 3 /8 23 /32 3/4 0.18 21 /32 15 /16 3/4 x 1 0.35 13 /16 1 3/4 x 112 0.20 9 /16 15 /16 1 0.43 25 /32 1 1 x 3/4 0.35 11 /16 1 1 x 112 0.26 9 /16 1 11/4 0.67 1 1 1 1/4 x 3/4 0.47 9 /16 1 11/2 0.89 1 1 2 1.46 1 1 6#0 C L Al -Et Ina 7 07- 3 -5 • 1' 1 1/ Elbo NOM. APPROX. DIM. A DIM. C E 3/8 0.12 11 /32 7 /16 11 /16 3/8 x 112 0.18 11 /32 9 /16 13 /16 1/2 0.15 13 /32 9 /16 7 /8 112 x 3/8 0.17 3 /8 1 /2 13 /16 3/4 0.28 17 /32 21 /32 15 /16 3/4 x 112 0.24 11 /32 9 /16 15 /16 1 0.49 5 /8 25 /32 1 1 1 '1' El APPROX. DIM. C DIM. E NOM. SIZE NET WT. /LBS. INCHES INCHES 1 707 -3 -6 90° Union Elbow C x F - Cast 112 0.31 1 7 /8 3/4 0.49 1 1 1 0.79 1 1 707 -4 90° Elbow C x M - Cast 3/8 0.08 5 /16 7 /8 1/2 0.12 7 /16 1 112 x 3/4 0.18 9 /16 1 112 x 3/8 0.10 5 /16 15 /16 3/4 0.21 9 /16 1 3/4 x 1 0.33 21 /32 1 3/4 x 112 0.18 7 /16 1 1 0.43 23 /32 1 11/4 0.58 7 /8 1 11/2 0.81 1 1 2 1.38 1 2 z � r mu n 707 -4 -6 90° Union Elbow C x M - Cast 3/8 0.21 1 1 112 0.30 1 1 3/4 0.49 1 1 1 0.72 1 1 11/4 1.16 1 1 46 j j , 1 • 1' Dr op Elbo APPROX. DIM. A DIM. C NOM. SIZE NET WT. /LBS. INCHES INCHES 1 1 1 •1' 11 C a st NOM. APPROX. DIM. A DIM. C DIM. D SIZE NETWTJLBS. INCHES INCHES INCHES 1 3/4 0.21 1 9 /16 9 /16 Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 ELBOWS continued FITTING REDUCERS 707 -6 90° Union Elbow C x C - Cast 3/8 0.17 31 /32 5 /16 112 0.24 1 7 /16 3/4 0.39 1 "/32 9 /16 1 0.64 1 23 /32 11/4 1.07 1 23 /32 I C 708 90° Flanged Sink Elbow C x F - Cast A --« F 112 0.20 1 /8 9 /16 1 D _ 764 90° Double Elbow CxCxC - Cast 1 x 3/4 x 3/4 0.33 3 /4 21 /32 Consult price sheet for Made to Order items and for minimum order quantities. 600 -2 Fitting Reducer Ftg x C - Wrot NOM. SIZE 1/4 x 1/8 Ae MPA . NET VVT.1LBS. 0.01 D 117 INCHES 15 /32 3/8 x 1/4 0.01 19 /32 3/8 x 1/8 0.01 25 /32 112 x 3/8 0.03 11 /16 112 x 1/4 0.02 25 /32 5/8 x 112 0.04 1 /8 5/8 x 3/8 0.04 31 /32 5/8 x 1/4 0.03 1'/32 3/4 x 5/8 0.06 31 132 3/4 x 112 0.06 1' /8 3/4 x 3/8 0.05 1' /8 3/4 x 1/4 0.05 1 1 x 3/4 0.10 1 1 x 5/8 0.09 1 1 x 112 0.09 1'/4 1 x 3/8 0.08 1 1 1/4 x 1 0.15 1 1 1/4 x 3/4 0.16 1 1 1/4 x 112 0.13 1 1 112 x 11/4 0.23 1 1 112 x 1 0.21 1 1 112 x 3/4 0.20 1 1 112 x 112 0.16 1 2 x 1112 0.40 1 2 x 11/4 0.34 2 2 x 1 0.35 1 2 x 3/4 0.35 1 2 x 112 0.34 1 21/2 x 2 0.65 1 21 12 x 1 112 0.65 2 21/2 x 1 1/4 0.60 2 21 12 x 1 0.78 2 3 x 21/2 1.03 2 3 x 2 0.99 2 3 x 1 112 0.81 2 3 x 1 1/4 1.29 3 31 12 x 3 1.48 2 "/32 - 6x2 4.51 Continues... 4 x 31 12 2.09 2 /a 4 x 3 2.00 3 4 x 21/2 1.56 3 4 x 2 1.76 3 13 /32 5 x 4 3.30 3 5 x 3 2.97 4 5 x 21 12 3.30 4 "/32 5 x 2 2.88 4 "/16 6 x 5 5.56 4 6 x 4 5.09 4 6 x 3 4.67 5 6 x 21 12 4.47 5 1 '/32 - 6x2 4.51 5 - 8x6 12.33 5 15 /32 8 x 5 10.35 5 - 8x4 11.10 6 8 x 3 10.63 6 8 x 21 12 11.41 7 8 x 2 10.86 7 FLANGES - CLASS 125 7 /16 � �i I - F C ompanion F. 1' NOM. APPROX. DIM. B DIM. F DIM. G r 112 0.55 '/8 3'/2 3 /16 2 3/4 0.71 '/8 3 3 /16 2 1 1.26 1 /8 4 1 /4 3 11/4 1.42 1 /8 4 1 /4 3 11/2 1.82 1 /8 5 5 /16 3 2 2.76 1 /8 6 3 /8 4 21/2 4.29 '/8 7 3 /8 5 3 5.26 1 /8 7 7 /16 6 4 7.60 1 /8 9 7 /16 7'/2 5 9.04 1 /8 10 7 /16 8 6 12.68 1 /8 11 1 12 9 NOTE: Dim. B = Tube Stop to Flange Face NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. ^ ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 FLANGES - CLASS 150 771 Companion Flange C - NOM. APPROX. DIM. B DIM. F SIZE NETVVTJLBS. INCHES INCHES 3/4 1.15 '/6 3 Cast DIM. G INCHES 11 /32 DIM. W INCHES 2 1 1.59 1 /8 4 3 /8 3 11/4 1.91 '/8 4 13 /32 3'/2 11/2 2.59 1 /8 5 7 /16 3 2 4.10 1 /8 6 1 12 4 2112 6.22 1 /6 7 9 /16 5'/2 3 8.03 1 /8 7'/2 5 /8 6 4 11.85 1 /8 9 11 /16 7 5 15.69 1 /8 10 3 /4 8'/2 6 20.32 1 /8 11 13 /16 9 NOTE: Dim. B = Tube Stop to Flange Face CD w E 775 Threaded Companion Flange F - Cast 2 4.31 1 2112 6.30 1' /8 PLUGS -- ��H 616 Fitted Plug Ftg - Wrot APPROX. DIM. A NOM. SIZE NET VVT.1LBS. INCHES 3/8 0.016 '/16 112 0.02 3 /32 3/4 0.24 '/6 638 Return Bend C x C - Wrot 1/8 0.02 21 /32 1 1/4 0.04 21 /32 1 3/8 0.08 1'/32 1 112 0.13 1 2 3/4 0.26 1 2'12 1 0.44 2 3 11/4 0.70 2 4 11/2 1.04 3 4'/2 2 1.92 3 5 \iii STRAPS 623 Copper Hanger Strap APP SIZE NET VVT./LBS. 3/4" Wide x 25 Ft. Roll 1.93 dftf 624 Tube Strap APP NOM. SIZE NET WT./LBS. 1/8 0.01 1/4 0.01 3/8 0.01 112 0.01 5/8 0.02 3/4 0.02 1 0.02 11/4 0.03 1 112 0.03 2 0.04 TEES C D- E 705 Baseboard Tee C x F x C- Cast 6 4 112 x 1/8 x 3/4 0.15 1 /16 9 /16 "/16 7 5 E 1 /2 x 1/8 x 112 0.11 1 /16 7 /16 9 /16 3 7.13 1 7 6 4 10.20 1 9 7 7 39 3/4 x 1/8 x 1 0.29 5 /8 3 A 13 /16 Return Bend - Closed 3/4 x 1/8 x 3/4 0.19 9 /16 9 /16 11 /16 C x C Cast 1 X 1 /8 x l 0.32 23 /32 23 /32 3 /4 APPROX. DIM. E DIM. J 11/4 x 1/8 x 11/4 0.51 7 /6 1 /8 15 /16 NOM. SIZE NET WT./LBS. INCHES INCHES 3/4 0.29 1 1 Consult price sheet for Made to Order items and for minimum order quantities. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Sa 705 -D VentElbowCxC - Cast 112 0.10 7 /16 7 /16 25 /32 3/4 0.20 9 /16 9 /16 29 /32 1 0.31 23 /32 23 /32 1 710 -3 TeeFxFxC - Cast 112 0.20 9 /16 7 A 7 /8 3/4 0.37 "/16 1 1 3/4 x 3/4 x 112 0.31 11 /16 31 /32 31 /32 3/4 x 112 x 3/4 0.29 11 /16 1 15 /16 3/4 x 112 x 112 0.27 11 /16 31 /32 7 /8 C 5� 710 -3 -4 Tee MxFxC -Cast 3/4 0.34 1 '/16 1 1 3/4 x 3/4 x 112 0.33 11 /16 1 31 /32 Consult price sheet for Made to Order items and for minimum order quantities. 611 TeeCxCxC - Wrot 3/160D 0.01 7 /32 7 /32 7 /32 1/8 0.02 '/4 1 /4 7 /32 1/8 x 1/8 x 1/4 0.02 13 /32 13 /32 '/4 1/8 x 1/8 x 3/160D 0.01 1 /4 1 /4 5 /16 1/8 x 3/160.D x 1/8 0,01 '/4 11 /32 7 /32 5/160D 0.02 3 /8 3 /8 5 /16 5 /16oD x 5 /16oD x 1/4 0.02 3 /8 3 /8 '/4 5/160D x 5 /16oD x 1/8 0.02 3 /8 3 /8 13 /32 5/160D x 1/8 x 5/160D 0.02 3 /8 13 /32 5 /16 5/160D. x 1/8 x 1/8 0.02 3 /8 13 /32 13 /32 1/4 0.02 5 /16 5 /16 1 /4 1/4 x 1/4 x 112 0.06 19 /32 19 /32 3 /8 1/4 x 1/4 x 3/8 0.04 17 /32 17 /32 1 '/32 1/4 x 1/4 x 5/160D. 0.02 5 /16 5 /16 5 /16 1/4 x 1/4 x 1/8 0.02 5 /16 5 /16 13 /32 1/4 x 1/4 x 3 /16oD 0.02 5 /16 5 /16 7 /16 1/4 x 5 /16o.D.x 1/4 0.02 5 /16 3 /8 1 /4 1/4 x 1/8 x 1/4 0.02 5 /16 13 /32 '/4 1/4 x 1/8 x 1/8 0.02 5 /16 13 /32 3 /8 3/8 0.04 " /32 11 /32 11 /32 3/8 x 3/8 x 112 0.07 17 /32 17 /32 3 /8 3/8 x 3/8 x 1/4 0.04 11 /32 11 /32 15 /32 3/8 x 3/8 x 5/160D 0.04 "/32 "/32 11 /32 3/8 x 3/8 x 1/8 0.04 11 /32 " /32 11 /32 3/8 x 1/4 x 3/8 0.04 17 /32 17 /32 " /32 3/8 x 1/4 x 1/4 0.04 11 /32 17 /32 15 /32 3/8 x 1/4 x 1/8 0.04 "/32 17 /32 9 /16 3/8 x 1/8 x 3/8 0.04 11 /32 79 /32 11 /32 3/8 x 1/8 x 1/8 0.04 11 /32 19 /32 19 /32 112 0.06 11 /32 11 /32 11 /32 112 x 112 x 1 0.29 1 1 21 /32 112 x 112 x 3/4 0.12 17 /32 17 /32 11 /32 112 x 112 x 5/8 0.11 5 /8 5 /8 7 /16 112 x 112 x 3/8 0.07 5 /16 5 /16 13 /32 112 x 112 x 1/4 0.06 5 /16 5 /16 9 /16 112 x 3/8 x 112 0.07 7 /16 17 /32 3 /8 112 x 3/8 x 3/8 0.06 5 /16 11 /32 13 /32 112 x 3/8 x 1/4 0.06 5 /16 17 /32 17 /32 112 x 1/4 x 3/8 0.06 5 /16 5 /8 9 /16 5/8 x 5/8 x 1/4 0.09 7 /16 Continues... NOTE: Tee sizes are read Run x Run x Outlet. 5/8 0.12 7 /16 7 /16 7 /16 5/8 x 5/8 x 3/4 0.15 23 /32 23 /32 '12 5/8 x 5/8 x 112 0.11 7 /16 7 /16 13 /32 5/8 x 5/8 x 3/8 0.09 7 /16 7 /16 5 /8 5/8 x 5/8 x 1/4 0.09 7 /16 7 /16 3 /4 5/8 x 112 x 5/8 0.10 7 /16 5 /8 7 /16 5/8 x 112 x 112 0.09 7 /16 19 /32 13 /32 5/8 x 3/8 x 5/8 0.10 7 /16 3 /4 7 /16 5/8 x 3/8 x 3/8 0.09 7 /16 3 /4 5 /8 3/4 0.15 '12 '12 '12 3/4 x 3/4 x 1 0.22 23 /32 23 /32 1 12 3/4 x 3/4 x 5/8 0.16 17 /32 17 /32 11 /16 3/4 x 3/4 x 112 0.12 7 /16 7 /16 77 /32 3/4 x 3/4 x 3/8 0.12 7 /16 7 /16 21 /32 3/4 x 3/4 x 1/4 0.12 13 /32 13 /32 23 /32 3/4 x 3/4 x 1/8 0.12 7 /16 7 /16 13 /16 3/4 x 5/8 x 3/4 0.15 17 /32 11 /16 1 /2 3/4 x 5/8 x 5/8 0.15 17 /32 23 /32 11 /16 3/4 x 112 x 3/4 0.15 17 /32 25 /32 1 12 3/4 x 112 x 112 0.12 13 /32 19 /32 1 12 3/4 x 112 x 3/8 0.12 7 /16 21 /32 21 /32 3/4 x 3/8 x 3/4 0.15 17 /32 17 /32 1 12 3/4 x 3/8 x 112 0.12 7 /16 23 /32 17 /32 3/4 x 3/8 x 3/8 0.12 7 /16 23 /32 21 /32 7/8 0.31 23 /32 23 /32 23 /32 1 0.30 11 /16 11 /16 2 '/32 1 x 1 x 1112 0.60 1 1 31 /32 1 x 1 x 11/4 0.42 1 1 29 /32 1 x 1 x 3/4 0.27 9 /16 9 /16 21 /32 1 x 1 x 5/8 0.26 9 /16 9 /16 7 /8 1 X 1 X 112 0.23 75 /32 15 /32 23 /32 1 X 1 X 3/8 0.23 15 /32 15 /32 29 /32 1 x 1 x 1/4 0.23 ' 15 /32 1 1 x 3/4 x 1 0.29 11 /16 7 /8 21 /32 1 x 3/4 x 3/4 0.26 9 /16 23 /32 3 /4 1 x 3/4 x 112 0.22 15 /32 21 /32 23 /32 Continues NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 TEES continued TEES continued I lik 4L L-i-T G C F 611 Tee C x C x C- Wrot continued APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. C F G I x 112 x 1 0.29 11 /16 1 2 '/32 1 x 112 x 3/4 0.27 9 /16 13 /16 3 /4 1 x 112 x 112 0.22 15 /32 25 /32 23 /32 11/4 0.43 13 /16 3 /16 13 /16 1 1/4 x 1 1/4 x 2 1.13 1 30 /32 1 30 /32 1 3 /32 1 1/4 x 1 1/4 x 1 112 0.60 1 3 /16 1 3 /16 29 /32 1 1/4 x 1 1/4 x 1 0.45 25 /32 25 /32 29 /32 1 1/4 x 1 1/4 x 3/4 0.37 21 /32 21 /32 3 /4 1 1/4 x 1 1/4 x 112 0.30 '12 '12 25 /32 1 1/4 x 1 1/4 x 3/8 0.34 23 /32 23 /32 29 /32 1 1/4 x 1 x 11/4 0.43 13 /16 1 1 /32 13 /16 1 1/4 x 1 x 1 0.47 25 /32 7 A 29 /32 1 1/4 x 1 x 3/4 0.35 21 /32 25 /32 7 /8 1 1/4 x 1 x 112 0.30 1 12 5 /8 29 /32 1 1/4 x 3/4 x 1 1/4 0.42 13 /16 1 1 /8 13 /16 1 1/4 x 3/4 x 1 0.45 25 /32 1 1 /32 29 /32 11/4 x 3/4 x 3/4 0.37 21 /32 75 /16 7 /8 11/4 x 3/4 x 112 0.30 1 12 3 /4 29 /32 11/4 x 112 x 11/4 0.41 13 /16 1 7 /32 13 /16 1112 0.61 31 /32 31 /32 29 /32 1112 x1 1/2x2 1.11 1 25 /32 1 25 /32 1 3 /32 1 112 x 1 112 x 11/4 0.62 29 /32 29 /32 1'/16 1 112 x 1 112 x 1 0.55 11 /16 11 /16 7 /8 1 112 x 1 112 x 3/4 0.45 11 /16 11 /16 1'/32 1 112 x 1 112 x 112 0.40 1 12 1 12 1'/32 1 112 x 1 1/4 x 1112 0.62 1 1 /32 1 3 /16 29 /32 1 112 x 1 1/4 x 11/4 0.62 31 /32 1 3 /32 31 /32 1 112 x 1 1/4 x 1 0.51 25 /32 1 1 1 /32 1 112 x 1 1/4 x 3/4 0.49 11 /16 13 /16 1'/32 1 112 x 1 1/4 x 112 0.41 '12 25 /32 1 1 /32 1 112 x 1 x 1112 0.59 1'/32 1 11 /32 29 /32 1 112 x l x 11/4 0.63 29 /32 1'/8 1'/16 1 112 x 1 x 1 0.54 25 /32 1 1 /16 1'/32 1 112 x 1 x 3/4 0.44 "h6 31 /32 15 /16 1 112 x 1 x 112 0.39 1 /2 25 /32 1'/32 1112 x 3/4 x 1112 0.62 1 1 /32 1 7 /16 1 1 /16 1112 x 3/4 x 11/4 0.58 29 /32 1 " / 32 1 1 /16 1112 x 3/4 x 1 0.54 25 /32 1 1 /4 1 1 /32 1112 x 3/4 x 3/4 0.47 11 /16 1 3 /32 29 /32 1112 x 3/4 x 112 0.39 '12 29 /32 31 /32 1112 x 112 x 1112 0.62 1 1 /32 1 13 /32 31 /32 Continues... 2 1.30 1 9 /32 1 9 /32 1 1 /32 2 x 2 x 21/2 2.34 2 2 1 21 /32 2 x 2 x 1112 1.17 1 1 1 23 /32 2 x 2 x 1 1/4 1.12 9 /32 9 /32 1 7 /8 2 x 2 x 1 0.90 27 /32 27 /32 1 2x 2 x 3/4 0.88 19 /32 19 /32 1 2 x 2 x 1/2 1.17 1 1 /4 1'/4 2 2 X 1 112 x 2 1.16 1 9 /32 1 7 /8 1 11 /32 2 x 1 112 x 1 112 1.15 1 1 3 /4 1 23 /32 2 x 1 112 x 1 1/4 1.15 7 /32 1 3 /4 1 "/32 2 x 1 112 x 3/4 0.83 21 /32 15 /16 1 7 /32 2 x 1 112 x 112 1.12 1'/4 1 25 /32 2'/4 2 x 1 1/4 x 2 1.58 1 9 /32 1 15 /32 1 9 /32 2 x 1 1/4 x 1112 1.16 1'/4 1 31 /32 1 23 /32 2 x 1 1/4 x 1 1/4 1.19 15 /16 1 11 /32 1 11 /32 2 x 1 1/4 x 1 0.90 27 /32 1 9 /32 1 11 /32 2 x 1 1/4 x 3/4 0.85 21 /32 1 1 8 /27 2 x 1 x 2 1.11 1 1 /8 1 25 /32 1 1 /4 2 x l x 1 0.89 27 /32 1 9 /32 1 11 /32 2 x 3/4 x 2 1.15 1 9 /32 2 3 /16 1 2 x 112 x 2 1.15 1 9 /32 2 3 /8 1 1 /4 21 12 2.40 1 5 /8 1 5 /8 1 5 /8 21/2 x 21/2 x 2 1.97 1 5 /16 1 5 /16 1 21 /32 21 12 x 21 12 x 1 112 1.53 1 3 /32 1 3 /32 1 21 /32 21 12 x 21 12 x 1 1/4 1.72 1 3 /32 1 3 /32 1 27 /32 21 12 x 21 12 x 1 1.34 25 /32 25 /32 1 11 /16 21 12 x 21 12 x 3/4 1.34 25 /32 25 /32 1 13 /16 21 12 x 21 12 x 112 1.34 25 /32 25 /32 2 1 18 21/2 x 2 x 21/2 1.99 1 21 /32 2 3 /32 1 21 /32 2 112 X 2 x 2 1.95 1 11 /32 1 5 /8 1 23 /32 21/2 x 2 x 1 112 1.57 1 2 13 /32 1 21 /32 21/2 x 2 x 1 1/4 1.57 1 1 1 21/2 x 2 x 1 1.40 25 /32 1 9 /32 1 21/2 x 2 x 3/4 1.35 25 /32 1 1 21/2 x 1 1/2 x 1 112 1.76 1 3 /32 1 1 3 /8 21/2 x 1 1/4 x 21/2 2.40 1 21 /32 2 7 /16 1 21 /32 21/2 x 1 x 21/2 2.04 1 2 23 /32 1 21 /32 21/2 x 3/4 x 21/2 2.00 1 2 11 /16 1 21 /32 21 12 x 112 x 21 12 2.46 1'/2 2 7 /32 1 1 12 Continues... NOTE: Tee sizes are read Run x Run x Outlet Continued on next page Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 O. NET W1 r INCHES 3 3.15 1 7 /8 1 2 1 /32 3 x 3 x 2 112 3.55 1 29 /32 1 29 /32 2 3 /8 3 x 3 x 2 3.19 1 75 /32 1 15 /32 1 31 /32 3 x 3 x 1 112 3.08 1 15 /32 1 15 /32 2 9 /32 3 x 3 x 1 1/4 3.10 1 75 /32 1 15 /32 2 7 /16 3 x 3 x 1 2.12 27 /32 27 /32 1 31 /32 3 x 3 x 3/4 2.39 27 /32 27 /32 2 3 /16 3 x 3 x 112 1.82 27 /32 27 /32 2 3 /8 3 x 21/2 x 3 3.08 1 7 /8 2 3 /8 1 31 /32 3 x 21/2 x 21/2 3.12 1 29 /32 2 11 /32 2 5 /32 3 x 21/2 x 2 2.28 1 15 /32 1 27 /32 1 31 /32 3 x 2 x 3 3.62 1 29 /32 2 17 /32 1 15 /16 3 x 2 x 2 112 3.56 1 29 /32 2 9 /16 2 5 /16 3 x 2 x 2 3.22 1 15 /32 1 31 /32 1 31 /32 3 x 1 112 x 3 3.13 1 29 /32 2 25 /32 2 3 /32 3 x 1 1/4 x 3 3.63 1 29 /32 2 25 /32 1 15 /16 3 x 1 x 3 3.20 1 31 /32 2 19 /32 2 3 /16 3 x 3/4 x 3 3.55 1 31 /32 2 29 /32 2 3 /16 3 112 5.20 2 17 /32 2 17 /32 2 17 /32 4 8.12 2 13 /32 2 13 /32 2 17 /32 4 x 4 x 3 6.70 2 1 /32 2 1 /32 2 21 /32 4 x 4 x 21/2 6.65 2 1 /32 2 1 /32 3 5 /32 4 x 4 x 2 5.82 1 1 15 /32 2 7 /16 4 x 4 x 1 112 3.94 1 11 /32 1 11 /32 2 17 /32 4 x 4 x 1 1/4 4.04 1 11 /32 1 11 /32 2 29 /32 4 x 4 x 1 3.72 1 1 2 9 /16 4 x 4 x 3/4 3.70 1 1 2 11 /16 40 3 x 4 7.05 2 25 /32 3 7 /32 2 17 /32 4 x 3 x 3 5.03 2 1 132 2 15 /32 2 15 /32 4 x 3 x 21/2 5.04 2 1 /32 2 15 /32 2 Z9 /32 4 x 3 x 2 5.87 1 1 31 /32 2 7 /16 4 x 21 12 x 4 7.19 2 25 /32 3 15 /32 2 27 /32 4 x 2 x 4 7.08 2 25 /32 3 19 /32 2 27 /32 Continued on next page Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 a Ek C F 611 Tee C x C x C- Wrot continued 5 NET WT 8.29 ,, INCHES 2 2 3 5 x 5 x 4 7.09 2 2 3 5 x 5 x 3 5.91 1 1 3 5 x 5 x 21/2 5.90 1 1 3 5 x 5 x 2 5.29 1 1 3 5 x 5 x 1 112 4.87 1'/32 1'/32 3 5 x 5 x 1 1/4 4.50 11 /16 " /16 3 5 x 5 x 1 4.20 9 /16 9 /16 3 5 x 4 x 5 8.53 2 4 3 5 x 4 x 4 8.17 2 1 /4 4 3 5 x 2 x 5 9.47 2 5 3 6 13.50 3 3 4'/32 6 x 6 x 5 11.67 2 2 4 6 x 6 x 4 10.17 2 2 3 "/16 6 x 6 X 3 8.92 1 1 3 6 x 6 x 21 12 8.11 1 1 3 6 x 6 x 2 7.78 1 1 3 6 x 6 x 1 112 6.86 1 1 3 6 x 6 X 1 1/4 6.66 29 /32 29 /32 3 6 X 6 x 1 7.19 9 /16 9 /16 3 6 x 6 x 3/4 7.18 9 /16 9 /16 4 6 x 6 x 112 7.17 9 /16 9 /16 4 6 x 4 x 6 16.60 3 5 4 6 x 4 x 1 112 9.62 15 /16 2 3 8 36.81 4'/16 4 5 8 x 8 x 6 27.86 3 3 5'/8 8 x 8 x 5 24.90 2 2 4 8 x 8 x 4 22.26 2'/16 2 4 8 x 8 x 3 20.01 1 1 4 8 x 8 x 21/2 19.02 1 1 4 8 x 8 x 2 18.01 1 /16 1 4 NOTE: Tee sizes are read Run x Run x Outlet Consult price sheet for Made to Order items and for minimum order quantities. 611 -HE Heat Exchanger Tee CxCxC - Wrot Tube slips entirely through fitting on small end of run. Sizes same as listed under 611 where tee has one or more reductions on one e o run. 1 4 d1 74 711 TeeCxCxC - Cast 1 1 /4 x 112 x 1 0.48 3 /4 3 /4 7 A 1 114 x 112 x 112 0.50 9 /16 5 /8 1 1 112 x 112 X 11/4 0.70 7 /8 31 /32 1 2 x 2 x 3 3.11 1 1 1 2 x 1 x1 112 1.23 1 1'/4 1 2 x 3/4 x 3/4 0.84 21 /32 7 /8 1 1 /4 21 12 x 21 12 x 3 2.98 1 1 1 21/2 x 1112 x 2 2.02 1'/4 1 1 21/2 x 1 112 x 1 112 1.76 1 1 1 21 12 x 112 x 21 12 2.46 1'/2 2 1 3 x 3 x 4 6.96 2 2 1 3 x 21 /2 x 1 112 2.53 1 1 1 3 x 2 x 1 112 2.62 1 1 1 4 x 4 x 6 16.47 3 3 2 4 x 2 x 2 4.64 1 1 2'14 711 -A Supply and Return Tee CxCxC - Cast 112 0.17 13 /16 1 SLE L I-T F 611 -2 Fitting TeeCxFtgxC - Wrot APPROX. DIMENSIONS NET WT. INCHES 112 0.07 1'/32 3 /8 7 /16 3/4 0.15 1 1 /2 17 /32 T A C C Drop Tee Ca APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. A C 1 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST, ^ ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 TEES continued TEES continued F p F F 712 TeeCxCxF - Cast 713 TeeCxCxM -Cast 3/8 0.11 " /16 7 /16 1 /16 112 0.14 13 /16 7 /16 7 /16 3/4 0.33 1 21 /32 21 /32 1 0.54 1 1 /4 7 /8 7 /8 1 112 1.08 1 1 1 2 1.74 1 1 1 112 x 112 x 1/4 0.16 13 /16 1 12 1 12 112 x 112 x 3/8 0.15 13 /16 1 12 '12 112 x 112 x 3/4 0.23 15 /16 "/16 " /16 3/4 x 3/4 x 3/8 0.23 7 /8 '12 '12 3/4 x 3/4 x 112 0.24 57 /64 17 /32 17 /32 1 1/4 x 11/4 x 112 0.49 1'/4 9 /16 9 /16 1 1/4 x 11/4 x 3/4 0.55 1 5 /16 11 /16 11 /16 1 1/4 x 11/4 x 1 0.66 1 7 /16 7 /8 7 /8 1 x 1 x 112 0.34 1 9 /16 9 /16 1 x 1 x 3/4 0.42 1 3 /16 11 /16 " /16 1 112 x 1112 x 112 0.62 1 9 /16 9 /16 1 112 x 1112 x 3/4 0.70 1 7 /16 11 /16 11 /16 1 112 x 1112 x 1 0.79 1 1 /2 13 /16 13 /16 2 x 2 x 112 0.97 1 17 /32 17 /32 2 x 2 x 3/4 1.10 1 11 /16 11 /16 11 /16 2 x 2 x 1 1.23 1 3 /4 13 /16 13 /16 1/4 0.08 13 /16 9 /32 9 /32 11/4 0.76 1 7 /16 1 1 3/8 x 3/8 x 1/4 0.12 "/16 7 /16 7 /16 3/4 x 112 x 3/4 0.28 1 21 /32 11 /16 3/4 x 3/4 x 1 0.40 1 7 /8 7 /8 c J c 712 -5 DropTeeCxCxF - Cast APPROX. DIMENSIONS 1 NET WT. INCHES 112 0.25 3 /8 9 /16 7 /8 3/4 0.38 1 /2 21 /32 1 698 Suction Line P -Trap CXC - tarot A major application of this fitting is on the suction line of a refregeration compressor. The line is looped, by use of the Suction Line P -Trap, to the floor prior to being run vertically upwards to prevent the drainage of oil back to the compressor during shut down periods. Additional P -Traps are used for each 20' or riser pipe. this prevents high velocity build -up as the oil or liquid begins to return to the compressor during this shut down period. 112 0.36 5 3 3 6 5/8 0.45 5 2 3 6 3/4 0.58 5 2 3 /4 3 6 1 0.92 5'/4 2 21 /32 3 6 11/4 1.16 5 2 3 6'/8 1112 2.32 7 3 5 9 2 3.93 8 3 6 9 7 /16 Consult price sheet for Made to Order items and for minimum order quantities. 1 /2 0.15 1 3 /32 7 /16 3/4 0.29 1 9 /32 9 /16 P111 _.t 714 TeeCxFxC - Cast 112 0.18 7 /16 9 /16 7 /8 112 x 3/4 x 112 0.27 7 /16 9 /16 1 3 /16 3/4 0.31 9 /16 11 /16 1 3/4 x 112 x 3/4 0.26 9 /16 9 /16 15 /16 1 0.52 23 /32 13 /16 1'/4 1 x 3/4 x 1 0.43 23 /32 23 /32 1 3 /16 1 x 112 x 1 0.42 3 /4 3 /4 1 1 1/4 0.70 7 /8 1 1 13 /32 1 1/4 x 3/4 x 11/4 0.62 7 /8 7 /8 1 7 /32 1 1/4 x 112 x 11/4 0.56 7 /8 7 /8 1 3 /16 1 112 1.00 1 1 1 9 /16 1 112 x 3/4 x 1112 0.88 1 1 1 13 /16 2 1.72 1' /4 1 1 2 x 3/4 x 2 1.57 1 1 1 /4 2 2 x 112 x 2 1.58 1 1 /4 1'/4 2 ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 TRAPS UNIONS OR WA 633 -W Union C x C - Wrot 1/8 0.10 5 /8 1/4 0.15 11 /16 3/8 0.22 7 /16 112 0.31 73 /32 3/4 0.33 3 /8 1 0.54 1 /2 733 A Union C x C - Cast 1/4 0.10 11 /16 3/8 0.15 7 /16 112 0.22 13 /32 5/8 0.31 21 /32 3/4 0.31 3 /8 1 0.54 1 /2 11/4 0.76 '/2 11/2 1.04 23 /32 2 1.77 '/z 2112 3.25 1 3 4.75 1 Consult price sheet for Made to Order items and for minimum order quantities. ■ ■ ■ ■ Fs� 112 0.23 1 APPROX. DIM. B NOM. SIZE NET WT. /LBS. INCHES 3/4 0.35 1 1 0.55 1 733 -3 Fitting Union C x F - Cast APPROX. DIM. A NOM. SIZE NET VJT./LBS. INCHES 1/4 0.14 1 3/8 0.19 1 112 0.26 1 3/4 0.37 1 1 0.61 1 11/4 0.98 1 1 112 1.21 1 2 1.90 2 ■ ■ illillllll ■ :Iililll' I 1/4 0.13 1 3/8 0.20 1 112 0.28 1 112 x 3/4 0.35 2 3/4 0.43 1 1 0.68 2'/8 11/4 0.95 2 1 112 1.35 2 2 2.17 2 21 12 4.13 3 VENTURI 4? 621 Venturi Insert - Wrot Converts any tee into a special purpose Venturi or scoop tee 1/2 0.01 3/4 0.02 1 0.03 11/4 0.04 Y's !IrA e s 748 90 °Y CxCxC -Cast 112 0.11 7 /32 7 /16 3/4 0.25 7 /16 5 /8 1 0.61 '12 13 /16 I A B 749 45 °Y CxCxC -Cast 112 0.15 1 7 /8 3/4 0.30 1 1 1 0.55 1 1 11/4 0.81 2 1 11/2 1.14 2 2 2 2.17 3 2 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 ....... -,^ m 100 Series - Heavy Flared 500 Series - Flared Adapters ......................... .............................23 Couplings ......................... .............................23 Elbows ........................... .............................23 Nuts ............................. .............................24 Tees ............................. .............................24 1509091:7099 The manufacturing plants at South Glens Falls, NY, Stuarts Draft VA Nawgdoches, TX and Reynosa, Mexico manufacture products under a Quality Managernent System conforming to the current revision of ISO-9001 International Standards ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART. IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455 ADAPTERS COUPLINGS ��111111111 �illlllli - 14 Heavy Flared Adapter APPROX. DIM.L NOM. SIZE NET WT. /LBS. INCHES 0.60 1 1.2 3 } 1 . •1'1.1 - APPROX. DIM. B NOM. SIZE NET WT. /LBS. INCHES 1 3/4 0.48 2 1 1.03 2 1112 1.99 3 2 3.22 3 504 Flared Adapter FL x M — Cast Consult price sheet for Made to Order items and for minimum order quantities. 1 0 1 H eavy • •1 Coupling APPROX. DIM.L NOM. SIZE NET WT. /LBS. INCHES 1'i 1 1. 70 5 501 r B ----I Flared Coupling FL x FL — Cast A NOM. SIZE NET VVE/1-13S. INCHES 112 0.45 2 3/4 0.60 2 1 1.24 3 11/4 2.18 3 11/2 2.65 3 2 4.03 4 ELBOWS 507 Flared 90° Elbow FL x FL — Cast APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES 112 0.54 1 3/4 0.77 1 1 1.60 2 2 5.39 3 1 Flar 91• El bo w APPROX. DIM. B DIM. E NOM. SIZE NET WT. /LBS. INCHES INCHES 1 3/4 0.69 1 1 1 1.43 2 2 1 Flared 90' Elbow FL x M — Cast APPROX. DIM. B DIM. E NOM. SIZE NET WT. /LBS. INCHES INCHES 0 .34 111/16 113/32 1112 2.80 3 2 3/4 0.55 1 1 1 1.34 2 2 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST ^ ^ ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 A A i l NOM. SIZE NET VVT./LBS. INCHES 112 0.29 1 3/4 0.58 2 1 0.88 3 1112 1.89 3 2 2.95 4 Consult price sheet for Made to Order items and for minimum order quantities. 1 0 1 H eavy • •1 Coupling APPROX. DIM.L NOM. SIZE NET WT. /LBS. INCHES 1'i 1 1. 70 5 501 r B ----I Flared Coupling FL x FL — Cast A NOM. SIZE NET VVE/1-13S. INCHES 112 0.45 2 3/4 0.60 2 1 1.24 3 11/4 2.18 3 11/2 2.65 3 2 4.03 4 ELBOWS 507 Flared 90° Elbow FL x FL — Cast APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES 112 0.54 1 3/4 0.77 1 1 1.60 2 2 5.39 3 1 Flar 91• El bo w APPROX. DIM. B DIM. E NOM. SIZE NET WT. /LBS. INCHES INCHES 1 3/4 0.69 1 1 1 1.43 2 2 1 Flared 90' Elbow FL x M — Cast APPROX. DIM. B DIM. E NOM. SIZE NET WT. /LBS. INCHES INCHES 0 .34 111/16 113/32 1112 2.80 3 2 3/4 0.55 1 1 1 1.34 2 2 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST ^ ^ ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 NUTS I /,( 00 1• Nut — Cast APPROX. DIM. B DIM. L NOM. SIZE NET VVT. /LBS. INCHES INCHES 0.20 1 1 /16 1 1 12 1 TEES 511 Flared Tee FL x FL x FL — Cast 112 0.67 1 5 /8 1 5 /8 1 5 /8 3/4 1.09 2 2 2 1 2.08 2 5 /8 2 5 /8 2 5 /8 Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Adapters ......................... .............................26 BrassPlug ......................... .............................27 Couplings ......................... .............................26 CrimpRings ....................... .............................26 CrimpTool ......................... .............................21 Elbows ........................... .............................26 Fitting Reducers .................... .............................26 Tees ............................. .............................26 Tube Cutter ........................ .............................27 'SOM11:2000 The manufacturing plants at South Glens Falls, NY, Stuarts Draft VA, Nacogdoches, TX and Reynosa. Mexico manufacture products under a Qual ity Management System conforming to the current revision of ISO -9001 International Standards NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 ADAPTERS uI'II i =1� wu PEX603 Adapter PEX x F — Wrot APP NOM. SIZE NET WT./LBS. INCHES 112 0.123 2 3/4 0.207 2 PEX 604 Adapter ' APPROX. DIM. A NOM. SIZE NET WT. /LBS. INCHES 0.110 0.196 MF■IE 11 PEX Adapter PEX x • i — Wrot APPROX. DIM. A NOM. SIZE NET WT. /LBS. INCHES 0 0 1 ' 111�1�1'q�ll I�I�111 P 600 Cou pling PEX x P EX — Wrot APPROX. DIM.A NOM. SIZE NET WT. /LBS. INCHES 11 . 3/4 0.056 2 COUPLINGS continued ,, r— A 2 1 - ' IIIII�III�� ' •11 ` 0.112 Cou 1 — 3/4 x 112 x 112 0.097 APPROX. DIM.A NOM. SIZE NET WT. /LBS. INCHES 1 1 0 :1 2 1 A �TYP PEX607 Elbow PEX x PEX — Wrot 112 0.045 1 3/4 0.084 1 1 /16 A PEX607 -FA Faucet Elbow PEX x Swivel FIP — Wrot 112 0.049 1'/16 PEX707 -3 -5 Drop Ear Elbow PEX x FIP — Wrot 112 0.187 21/4 FITTING REDUCERS QQ � A —j - E)Rf� PEX600 -2 Fitting Reducer Ftg x PEX —Wrot APPROX. NUM. SIZE NET VJT./LBS. INCHES 112 0.035 1 3/4 0.059 1 TEES jL ,���,,, � y'�o1�r� • Tee PEX x PEX x P EX — Wrot 112 0.070 2 1 1 — 3/4 0.097 2 1 1 — 1 12 x 112 x 3/4 0.112 2 1 1 — 3/4 x 112 x 112 0.097 2 1 1 1 3/4 x 112 x 3/4 0.112 2 1 1 1 3/4 x 3/4 x 112 0.099 2 1 1 - CRIMP RINGS N r MI 3 FA PEX198 Crimp Rings (Black) APP NOM. SIZE NET WT./LBS. INCHES 112 0.013 0.325 3/4 0.017 0.325 Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 CRIMP TOOL Crimp Tool APPROX. NOM. SIZE NET WT. /LBS. 11 112 3.005 3/4 3.005 1 4.000 E:1 PEX100 Tube Cutter 0.03 Brass P lugs APPROX. NOM. SIZE NET WT. /LBS. 0 11 0.0457 0.0801 Consult price sheet for Made to Order items and for minimum order quantities. , NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Copper Insert Fittings for Polybutylene Couplings ......................... .............................29 CrimpRings ....................... .............................29 Elbows........................... .............................29 Faucet Connectors .................. .............................29 Tees............................. .............................29 �. IS0900 -.. ll=;::l The manufacturing plants at South Glens Falls, NY, Stuarts Draft VA Nacogdoches, TX and Reynosa, Mexico manufacture produM under a Quality Management System conforming to the current revision of ISO -9001 International Standards m NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 ' TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574295.3221 • FAX: +1.574.295.3455 COUPLINGS PB600 C oupling Barb x Barb APPROX. 7 NOM. SIZE NET WT. /LBS. 11 0.06 ELBOWS PB607 90' Elbow — Barb x Barb 112 0.04 3/4 0.06 FAUCET CONNECTORS s4 ' � : PB600 -FA Straight Faucet Connector — Barb x Swivel FIPS 112 without nut & washer 0.03 Consult price sheet for Made to Order items and for minimum order quantities. FAUCET CONNECTORS PB607 -FA 90' Elbow Faucet Connector — Barb x Swivel FIPS 112 without nut & washer 0.04 TEES it p PB611 Tee — Barb x Barb x Barb 112 0.05 112 x 112 x 3/4 0.10 3/4 0.10 3/4 x 3/4 x 112 0.08 3/4 x 112 x 3/4 0.10 3/4 x 112 x 112 0.08 CRIMP RINGS Crim Ring Coppe APPROX. NOM. SIZE NET WT. /LBS. 11 3/4 0.02 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.2953221 • FAX: +1.574.295.3455 Wrot and Cast DWU Fittings Adapters .......................... ..........................31 -33 Bushings ......................... .............................33 Cleanouts ......................... .............................33 Closet Flanges ..................... .............................34 Couplings ...................... ............................... 34 Elbows ........................... ..........................35 -36 Plugs ............................ .............................36 ReturnBends ...................... .............................40 Tees ............................. .............................31 Test Caps & Tees ................... ..........................31 -38 Traps ............................. ..........................39 -40 T -Y's ............................. .............................38 Y ' s ............................... .............................38 IS09001: 7 000 The manufacturing plants at South Glens Falls, NY, Stuarts Draft, V& Nacogdoches, TX and Reynosa, Mexico manufacture products under a Quality Management System conforming to the current revision of ISO -9001 International Standards m NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST • ELKHART, IN 46516 -4740 • USA • PH. 1.800.234.0227 TECH SERVICES PH: 1.888,446 4226 • FAX: 1.800234.0557 • INTERNATIONAL SERVICE PH: +1.574.2953221 • FAX: +1.574.295.3455 ADAPTERS - SLIP JOINT 801 -2 -7 DWV Fitting Trap Adapter Ftg x SJ — Cast APPROX. DIM. B NOM. SIZE NET WT./LBS. INCHES 11/4 x11 /40.D. 0.25 1 19 /32 901 -2 -7 DWV Fitting Trap Adapter Ftg x SJ — Wrot APPROX. DIM. B NOM. SIZE NET VVT./LBS. INCHES 1112 x 1112 O.D. 0.29 1 7 /16 1112 x 11/4 O.D. 0.24 1 7 /16 oil 1w 901 -7 DWV Trap Adapter C x SJ — Wrot 11/4 x 1 1/4 O.D. 0.21 21 /32 1112 x 11/2 O.D. 0.27 3 /4 1 112 x 1 1/4 O.D. 0.24 7 /6 Consult price sheet for Made to Order items and for minimum order quantities. 903 -7 DWV Trap Adapter FxSJ — Wrot 1 1/4 x 1 1/4 O.D. 0.32 1 7 /16 1112 x 1112 O.D. 0.42 1 7 /16 1112 x 11/4 0. D. 0.43 1 19 /32 FF —t 3 x 4 2.78 3 904-7 DWV Trap Adapter M x SJ — Wrot 11/4 x 1 1/4 O.D. 0.41 1 3 /4 1112 x 1 112 O.D. 0.51 1 25 /32 1 1 /2 x 1 1/40,D. 0.49 1 29 /32 805 DWV Soil Pipe Adapter C x Spigot — Cast Joins copper tube to cast iron soil pipes. 1 1/4x2 0.93 3 9 /32 2 x 4 2.52 3 3 1.56 2 4 1.23 13 /16 4 2.23 3 905 DWV Soil Pipe Adapter C x Spigot — Wrot Joins copper tube to cast iron soil pipes. 1112 x 2 0.60 3 7 /16 2 0.44 2 9 /16 805 -N DWV No Hub Soil Pipe Adapter C x No Hub— Cast 1 112 x 2 0.42 1 7 /32 2 0.40 1 3 /16 3 0.75 1 3 /16 4 1.23 1 7 /32 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.422 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 31 ADAPTERS — SPECIAL LEAD �4 fi 801 -T DWV Trap Adapter C x OR D. Tube — Cast 11 /4x11 /40.D. 0.21 '/a 1112 X 1112 0. D. 0.22 '/32 1112 x 11/4 0. D. 0.20 9 /32 ADAPTERS — THREADED 802 DWV Adapter CxM — Cast it I II 1 1/4 0.23 15 /16 '/16 1 1/4 x 1112 0.41 1 '12 1 112 0.25 1 '/16 2 0.33 1 ' /16 3 0.92 1 3 /4 19 is 802 -C DWV Flush Adapter CxM — Cast APPROX. DIM. B i NOM. SIZE NET VVT./LBS. INCHES INCHES 11/4 0.16 15 /16 '/16 1112 0.20 15 /16 9 /16 2 0.23 1 5 /6 ADAPTERS — THREADED continued ouc -r DWV Threaded Piece CxM —Cast Makes slip joint connection when soldered to the end of tube and slip joint nut and washer added. 11/4 0.05 3 /8 1112 0.05 3 /a 2 0.05 3 /e 803 DWV Adapter CxF — Cast APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 3 1.45 1 4 2.31 1 903 DWV Adapter CxF — Wrot 11/4 0.19 27 /32 1112 0.25 29 /32 2 0.41 1 :1 DWV Fitting `d.p• APPROX. DIM. B NOM. SIZE NET VVT. /LBS. INCHES 1 ■I: ., DWV Fitting Adapte APPROX. DIM. B NOM. SIZE NET VVT. /LBS. INCHES 1 N 111111 804 DWV Adapter CxM — Cast 1 112 0.34 1 1112 x 2 0.55 1 1112 x 1 1/4 0.31 21 /32 2 0.43 '/8 2 x 1 112 0.52 15 /16 3 1.35 1 4 2.59 2'/32 Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST- • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 ADAPTERS — I BUSHINGS I CLEANOUTS THREADED continued �lNIIiI 904 DWV Adapter C x M – tarot 11/4 0.30 1 11/4 x 1112 0.37 1 FIRM 804 -T �---- i —I DWV Trap Adapter ORTubexM – Cast 1 1/4 0 D. x 1 112 0.44 1 M r // ■ 1iiI1S ■ �u _v 0 DWV Fittin X 1.1 • 1 APPROX. DIM. B NOM. SIZE NET WT. /LBS. INCHES 1 1 2 0, 71 2'132 Consult price sheet for Made to Order items and for minimum order quantities. Aft E3B :1 D WV External Bushin 1 APPROX. DIM.A NOM. SIZE NET WT. /LBS. INCHES 0 . 6 1 V/32 4 x 3 1.12 1 3 x 1112 0.60 1 4 x 2 1.16 1 /a 901 -2 DWV External Bushing Ftg x C – Wrot APPROX. DIM. A NOM. SIZE NET WT./LBS. INCHES 1112 x 11/4 0.13 1 2 x 1112 0.19 1 2 x 11/4 0.19 1 •1 DWV Fittin Flush Bushin / / APPROX. DIM. B DIM. C NOM. SIZE NET WT. /LBS. INCHES INCHES 1 816 DWV Fitting Cleanout Ftg x Cleanout w /Plug – Cast APPROX. DIM. 13 NOM. SIZE NET WT./LBS. INCHES 1 1/4 0.49 2 1112 0.60 2 /4 2 0.87 2 3 2.37 3 4 3.99 3 816 -S DWV Flush Fitting Cleanout Ftg x Cleanout w /Plug – Cast PPP NOM. SIZE NETVVT./LBS. INCHES 11/4 x 3/4 0.20 1 1112 x 1 0.29 1'/16 2 x 1112 0.42 1 3 x 2 112 0.96 1 4 x 3 2.25 2'/8 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST ^ • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 CLOSET FLANGES »ms�c ■rte 851 DWV Closet Flange C — Cast 4 1.45 5 /6 7 6 40 3 2.18 1 7 6 --------- - - - - -- ....... .. . . ............. — I . 951 DWV Closet Flange C — Wrot 4 x 3 0.84 1 6 6 l - __ l 851 -C DWV Closet Flange C — Cast 4 x 3 1.31 1 1 12 6 6 801 DWV Coupling CxC — Cast 3 x 2 0.70 17 /16 3 x 1 112 0.68 15 /16 4 x 3 0.98 9 /32 4 x 2 1.34 1 901 DWV Coupling CxC — Wrot APPROX. DIM. A NOM. SIZE NETWT./LBS. INCHES 1 1/4 0.07 3 /32 1112 0.09 3 /32 1112 x 1 1/4 0.13 5 /16 2 0.14 3 /32 2 x 1112 0.19 15 /32 3 0.45 3 /32 4 0.57 1 /e 901 -RP DWV Repair Coupling (No Stop) CXC — Wrot 1112 0.09 1 2 0.14 1 3 0.42 1 4 0.57 2 Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455 ELBOWS 8I• 1 bo • APPROX. DIM.0 NOM. SIZE NET WT. /LBS. INCHES 4 2.47 1 •1• 1 Elbo APPROX. DIM.0 NOM. SIZE NET WT. /LBS. INCHES 1 1112 0.21 9 /16 2 0.38 13 /16 3 0.78 1 0 DWV 45' Fitting Elbo APPROX. DIM. B DIM. C NOM. SIZE NET WT. /LBS. INCHES INCHES Il k 0 1 Elbo APPROX. DIM.B DIM.0 NOM. SIZE NET WTJLBS. INCHES INCHES 1 1112 0.21 1 9 /16 2 0.39 1 13 /16 3 0.84 1 7 /8 1 FE �LJ 807 DWV 90° Elbow CxC — Cast APPROX. i NUM. SIZE NET WT./LBS. INCHES INCHES 1 112 x 1 1/4 0.43 1 1 2 x 1 112 0.71 1 1 3 2.30 2 2 4 3.92 3 3 907 DWV 90° Elbow CxC — Wrot 11/2 0.32 1'/16 1 1 1/4 0.18 1 1 2 0.58 1 1 Consult price sheet for Made to Order items and for minimum order quantities. 3 1.20 2 2 •1 DWV 90' Long Radius Elbow APPROX. DIM.0 NOM. SIZE NET WT. /LBS. INCHES 0 .41 2 2 0.62 2 i SI DWV 90'Fitting Elbo APPROX. DIM. B DIM. C NOM. SIZE NET WTJLBS. INCHES INCHES :' 4"/16 3 907 -2 DWV 90' Fitting Elbow Ftg x C — Wrot APPROX. DIM. B DIM. C NOM. SIZE NETW11LBS. INCHES INCHES 1 1/4 0.19 1 1 1112 0.33 2 1 7 /16 2 0.59 2 1 3 1.21 3 2 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 3 ELBOWS continued 807 -3 DWV 90° Elbow CxF — Cast NOM. SIZE NET WT. /LBS. INCHES INCHES 1 2 1.15 17/8 211/16 A V4 - . , - 807 DWV •1' E I 11 Cast APPROX. DIM.0 DIM E NOM. SIZE NET WT. /LBS. INCHES INCHES 0.66 i 807 -9 DWV 90° Elbow w /Side Inlet CxCxC — Cast 3 x 3 x 2 2.55 2 7 /8 1 5 /8 2 7 /8 837 LEI DWV 90 ' Double Elbow CxCxC—Cast APPROX. DIM. C DIM. G NOM. SIZE NET WT. /LBS. INCHES INCHES 1 2 x 1112 x 1112 0.97 1 5 /8 1 1 12 go C 0 1 11 Cast APPROX. DIM. NOM. SIZE NET WT. /LBS. INCHI 1 1112 0.28 '/4 2 0.48 11 /32 3 0.99 17 /32 809 DWV 11 1 /4° Elbow CxC — Cast APPROX. NOM. SIZE NETWT/LBS. INCHES 1112 0.22 5 /32 2 0.38 3 /16 ••0 DWV •1' Elbow APPROX. DIM. INOM. SIZE NET WT. /LBS. INCHE 0.24 13 /16 2 0.44 1 1 /8 3 0.95 1 7 /8 1 L 861 -LH DWV 90° Elbow w /Low Heel Inlet CxCxC — Cast APPROX. NOM.SIZE NETWT./LBS. INCHES INCHES 3 x 3 x 2 2.43 2 7 /8 1 9 /32 818 A.S.A, DWV Plug M — Cast NOM. SIZE APPROX. NET WT./LBS. INCHES 3/4 0.08 23 /32 1 0.12 29 /32 11/4 0.19 31 /32 1 112 0.21 1 3 /32 2 0.34 15 /16 Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 TEES _ -_. r _. 811 -14 ° 811 DWV Tee t DWV Tee CxCxF - Cast CxCxC - Cast 3 2.84 2 1 2 3 x 3 x 2 1.82 2 1'/8 1 3 x 3 x 1 112 1.58 2 15 /16 1 4 4.92 3 2 3 4 x 4 x 3 3.49 3 "/32 1 2 4 x 4 x 2 2.91 2 1 1 }. - _ I a � 3 1 911 DWV Tee CxCxC - tarot 11/4 0.32 1'/8 13 /16 1' /8 1 112 0.49 1 29 /32 1 1112 x 1112 x 11/4 1.58 2 15 /16 1 2 0.78 1 1' /8 1 2 x 2 x 1 112 0.73 1 15 /16 1 2 x 2 x 1 1/4 0.51 1'/2 13 /16 1 /8 20 1 1/2 x 2 0.80 1 1 1 20 1 1/2 x 1 112 0.73 1 1'A 1 Consult price sheet for Made to Order items and for minimum order quantities. 1 1 0.88 2 13 /16 1 2 1.57 2 1 1 2 X 2 X 1 112 1.17 2 7 /8 1 wv 811 -15 DWV Tee CxFxF - Cast C I CxUxCXC -Cast 11/4 0.65 1 3 /4 1 11/2 0.85 1 13/16 113/16 11/2x11/2x11/4x11/4 0.72 1 3 /4 75 /32 2 1.38 1'/8 1 1 2 x 2 x 1 1 /2 X 1 112 0.99 1 7 /8 1 2 x 2 x 1 1 /4 x 1 1/4 0.93 1 "/32 25 /32 1 2 x 1 1 /2 x 1 1 /2 x 1 112 0.94 1 25 /32 1' /16 3 x 3 x 2 x 2 2.36 2 1'/8 1' /8 3 x 3 x 1 1 /2 x 1 1 12 1.51 2 " /32 1" /32 FNOM. APPROX. DIMENSIONS NET WT. INCHES SIZE LBS. C D L M TEST CAPS 917 -B Test Caps - Copper C - Wrot 112 0.01 3 /16 3/4 0.01 3 /16 1 0.01 1 /8 11/4 0.01 '/4 1 112 0.01 1 /4 2 0.02 '/4 3 0.03 'A 4 0.05 5 /16 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST^ . ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 11/4 0.73 1 1'/2 15/32 TEST TEES 4& . . �_ T 1 814 DWV Test Tee C x C x Cleanout w /Plug — Cast APPROX. DIM. E DIM. F _NOM.SIZE NETWT./LBS. INCHES INCHES 1112 1.00 2'/16 1'/8 2 1.35 2 1 '/32 1 3 3.78 3 1 T -Y's r 0 812 DWV Long Turn T -Y CxCxC — Cast 11/4 0.93 2 1 2 13 /32 1112 0.87 3 2'18 3 '/16 2 1.84 4'/4 2 4 1 12 2 x 2 x 1112 1.07 3 2 3/32 '/3z 3 3.49 6'/16 4732 6 3 /4 3 x 3 x 2 2.78 4'/e 3'/16 4 3 /32 °� J 836 KJ DWV Double Long Turn T -Y CxCxCxC — Cast 1112 1.25 3 2 3 '/32 2 0.87 3 2'/8 3 '/16 2 x 2 x 1112 x 1112 1.96 3 2 3'/32 '/32 2 x 2 x 11/4 x 11/4 2.67 3"/16 2 3'/32 '/32 Y's continued �f 810 DWV 45° Y CxCxC — Cast 4tO4JCm 11/4 0.60 2 2 3 /8 - 11/2 0.94 2 2 '/2 — 2 1.26 2'/8 2 11 /32 — 2 x 2 x 1112 1.15 2 11 /16 2 3 /16 — 2 x 2 x 1 1/4 1.01 2 2 1 '/32 '/16 — 2x1 112 x 2 1.16 2 11 /32 2 "/32 — 2x1 112 x 1112 0.84 2 2 5 /16 — 3 3.19 4 4 45 /64 - 3 x 3 x 2 2.02 3 1 '/32 3 '/8 — 3 x 3 x 11 12 1.69 374 2 - 3 /16 4 5.55 5 5 1 — 4 x 4 x 3 3.96 4"/16 472 5 /16 - 4 x 4 x 2 2.90 4'/32 3 13 /16 — 3 /8 834 DWV 45' Double Y CxCxCxC —Cast 2 1.90 2'/8 278 1 732 — 2 x 2 x1 112 x 1112 1.26 2 "/16 2 3 /16 — 3 4.20 4 0/32 25 /32 - 3 x 3 x1 112 x 1112 2.09 3'/4 2 — 5 /16 Consult Price sheet for Made to Order items and for minimum order quantities, ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 F 890 3 x 5 DWV Drum Trap w /Bottom Inlet C x F x Cleanout w /Plug — Cast APPROX. NET WT. INCHES 1112 1.97 3 1'12 2 WKO � S 1 891 t 3 x 6 DWV Swivel Drum Trap C x C x Cleanout w /Plug — Cast APPROX. DIMENSIONS NET WT. INCHES 1112 2.90 6 1'12 1 3 .. DWV ' .1 w/Cleano Cl eanout ' 1 — Castl APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. A E J K :1 1 2'132 2'12 3 2 2.66 P/8 2 3 4 Consult price sheet for Made to Order items and for minimum order quantities. ET AM0 .. DWV ' .1 APPROX. DIMENSIONS NET WT. INCHES NOM. SIZE LBS. A E J K 1 1' 2/32 2 3 L 884 DWV P -Trap w /Cleanout C x C x Cleanout w /Plug — Cast APPROX. DIMENSIONS NETWT. INCHES 11/4 1.21 1 1 2'14 3 1112 1.53 1 2'12 3 17 /32 2 2.26 1 1 3 4 3 5.74 2 1 4 5 885 DWV P -Trap CxC — Cast 11/4 1.09 1 1 2 3 1112 1.45 1 2'12 3 2 2.11 1 7 /8 1 3 4 3 5.17 2 1 4 3 1 112 1.86 1 3 2 3 2 2 1 75 /32 3 3 3 ■ 892 -3 DWV P -Trap w /Union Joint FxSJ — Cast 2 2.89 1 3 3 3 DWV P -Trap w /Union Joint F x SJ x Cleanout w /Plug — Cast APPROX. NET WT. INCHES 1112 1.88 1 2 2 3 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. ^ ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1800 234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 bzj c DWV P -Trap w /Union Joint CxSJ — Cast TRAPS TRAPS Cont. E 875 -S DWV Trap Upturn MxS — Cast 1112 1.20 1 41 /64 1 9 /64 4 R ETURN BENDS 878 DWV Return Bend w /Cleanout C x C x Cleanout w /Plug — Cast APPROX. DIMENSIONS NETWT. INCHES 11/4 0.81 1 17 /32 2 — 1112 0.98 1 15 /32 2 — 3 3.34 1 15 /16 4 - 2 1.40 1 13 /32 3 — 879 DWV Return Bend CxC — Cast 11/4 0.76 1 17 /32 2 — 11/2 0.90 1 15 /32 2'12 — 1 112 x 1 112 o.D. 1.00 1 15 /32 2 1 /2 — 2 1.25 1 13 /32 3 — 2 x 1112 O.D. 1,23 1 17 /32 3 1 19 /32 2 x 1112 1.37 1 17 /32 3 1 19 /32 3 2.77 1 15 /16 4 — Consult price sheet for Made to Order items and for minimum order quantities. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Engineering Data Engineering Data continued Brazing Alloy Consumption...................... .............................45 Brazing Fittings Dimensions....................... .............................49 Friction Loss Allowances ........... ............................... 56 Installation Techniques .............. ..........................86 -87 Tolerances........................ .............................49 Copper Tube Fittings Brazing Information ................. .............................45 Fitting Terms and Abbreviations ..... ............................... 42 Plumbing System Failures .......... ............................... 43 Rated Internal Working Pressures ... . . ... . . .. . . . . ... . . . . ... . . . ... 46 -47 Solder and Flux Requirements ...... ............................... 45 Solder Joint Specification .......... ............................... 44 Tolerances........................ .............................63 Types of Joints ..................... .............................42 Copper Water Tube Comparative Data with Iron Pipe ....... . .... . . ............. . .... . .. 54 Dimensional Data ................... ..........................50 -53 Expansion and Contraction ......... ............................... 55 Internal Working Pressures . . . . .... . . . ................. . ........... 57 Selection of Tube Sizes ............ ............................... 56 Tolerances ........................ ..........................50 -53 Types, Standards, Applications, Tempers and Lengths ... . . . ...... . .. . .. 84 Water Flow and Friction Loss .... ............................... 58 -83 Frequently Asked Questions ...... ............................... 90 Joints Abbreviations ...................... .............................42 Brazing........................... ..........................86 -87 Soldering......................... .............................85 Types............................ .............................42 Solder and Flux Ratings........................... .............................46 Requirements ...................... .............................45 Solder Joint Fittings Dimensions ....................... .............................48 Friction Loss Allowances .......................................... 56 Installation Techniques .............. .............................85 Tolerances ........................ .............................48 Specifications Tolerances Fittings............................................... 44,48 -49 Tubing......................... ..........................50 -53 Valves Friction Loss Allowances ....... ............................... 56 Working Pressures Joints......................... ..........................46 -47 Tubing............................................... 50 -53,57 Installation Instructions The Fine Art of Brazing ........ ............................... 86 -87 The Fine Art of Soldering ......... ............................... 85 Polybutylene Installation ......................... . . .... . . . .... . . 89 Polyethylene (PEX) Installation ... ............................... 88 Numerical Index Numerical Index .......................... . ..................... 92 rsoeoo+:zooa The manufacturing plants at South Glens Falls, NY, Stuarts Draft VA, Nacogdoches, TX and Reynosa, Mexico manufacture products under a Quality Management System conforming to the current revision of ISO -9001 International Standards NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.2953455 Copper Tube Fittings TYPES OF JOINTS Flared Joint — The principle of the flared joint was first developed for copper tube plumbing in 1928 by NIBCO. The flared type joint is wholly a mechanical means of joining copper tubes. The tube nut is placed over the end of the copper tube to be joined; the tube end then is flared out at an approximate 45 degree angle by a flaring tool. The flared end is then drawn up by the tube nut so the inside surface is tightly secured against the ball seat of the fitting. This joint can be readily dismantled at any time and is, in effect, a type of union connection. Its use is generally restricted to soft (annealed) copper tubes since hard drawn tubes would be subject to splitting when flared (if the ends were not previously annealed). The flared ends of NIBCO Flared Fittings are produced to the requirements of ASME 616.26, "Cast Copper Alloy Fittings for Flared Copper Tube." Solder Joint — NIBCO pioneered the development of the solder joint and its application to the field of copper tube piping. Today the solder joint is widely adopted, as evidenced by the majority of cities and states that have written codes to include copper tube and solder joints as desirable for general plumbing, water lines, vent, stack, waste and drain lines, as well as other uses in industry. Testing has shown that often the solder joint has greater strength than the tubes being joined, depending upon the soldering alloy selected. While the method of preparing a solder joint is an exacting art to insure a full strength joint, it can be readily mastered by skilled tradesmen. It is for this reason — to insure the public of the protection afforded by properly prepared joints — that NIBCO products are marketed through the reputable sources of supply to the piping trades. Important procedures for preparing a solder joint are graphically illustrated in this catalog on page 95. Brazed Joint— This type of joint has long been used wherever and whenever critical situations have been encountered in copper piping. The joint itself is completed much in the same manner as the solder joint; however, considerably more heat and several refinements of technique require separate procedures that are described further in this catalog on pages 96 -97. Threaded Ends — To adapt copper tube to equipment having National Standard Pipe Taper (NPT) threads or to add copper tube to existing iron pipe installations or other threaded connections, NIBCO provides fittings having both external and internal NPT threads. These threaded ends are produced to the requirements of ASME 131.20.1, "Pipe Threads, General Purpose (Inch)." Flanges — To adapt copper tube to equipment having flanged connections, or to add copper tube to flanged pipe installations or other purposes, NIBCO provides flanges. The flanges are produced in two standard types widely used in this field where copper tube can serve — Class 150, comply with ASME 1316.24, "Cast Copper Alloy Pipe Flanges and Flanged Fittings Class 150, 300, 400, 600, 900,1500 and 2500 "; and Class 125, which conform to MSS SP 106, "Cast Copper Alloy Flanges and Flanged Fittings Class 125, 150 and 300." Barbed Insert Fittings for Polybutylene (PB) — NIBCO offers a complete line of copper barbed insert fittings for joining PB tube. The insert fittings are produced to the requirements of ASTM F 1380. Along with the insert fittings are copper crimp rings, which, when properly installed, provide a leak -tight mechanical joint. Transition fittings are available for adapting to new or existing threaded or solder joint ends. Barbed Insert Fittings for PEX — NIBCO offers a complete line of copper barbed insert fittings for joining PEX tube. The insert fittings are produced to the requirements of ASTM F 1807. Along with the insert fittings are copper crimp rings, which, when properly installed, provide a leak -tight mechanical joint. Transition fittings are available for adapting to new or existing threaded or solder joint ends. Fitting Terms and Abbreviations C Female solder cup Ftg Male solder end F Female NPT thread M Male NPT thread Hose Standard hose thread Hub Female end for soil pipe Spigot Male end for soil pipe No Hub Used with mechanical coupling O.D. Tube Actual tube outside diameter S Straight thread SJ Slip joint FL Flared ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Failure in a copper plumbing system is rare, but may occur due to a variety of reasons. The most common causes of failure are: Excessive fluid velocity causes erosion - corrosion or impingement (to strike or hit against) attack in the tube and /or fitting. For this reason, the copper plumbing industry has establish design velocity limits for copper plumbing systems to the following: Hot Water > 140 °F (60 °C) 2 to 3 feet per second (0.6 to 0.9 meters per second) Hot Water 140 °F (60 °C) 4 to 5 feet per second (1.2 to 1.5 meters per second) Cold Water 5 to 8 feet per second (1.5 to 2.4 meters per second) 2. Localized high velocities and /or turbulence. The presence of a dent, tube ends which are not reamed or deburred before soldering, and sudden changes in direction can all cause localized high velocity conditions. 3. Flux Corrosion is typified by pin hole leaks, generally in the bottom of a horizontal line. Fluxes are mildly corrosive liquid or petroleum -based pastes containing chlorides of zinc and ammonia. Unless the flux is flushed from the system, it will lay in the bottom of the tube and remain active. ASTM B 813, "Liquid and Paste Fluxes for Soldering Applications of Copper and Copper -Alloy Tube," limits the corrosivity of soldering fluxes and ensures that these fluxes are flushable in cold water, which facilitates easy removal of flux residue following installation. 4. Galvanic Corrosion may be defined as the destruction of a material by electrochemical interaction between the environment and the material. Generally, it is slow but persistent in character and requires the presence of dissimilar metals. Galvanic corrosion requires the flow of an electric current between certain areas of dissimilar metal surfaces. To complete the electric circuit, there must be two electrodes, an anode and a cathode, and they must be connected by an electrolyte media (water) through which the current can pass. The amount of metal which dissolves at the anode is proportional to the number of electrons flowing, which in turn is dependent upon the potential and resistance of the two metals. The use of dissimilar metals in a plumbing system may or may not create a problem. For instance, copper and steel are perhaps the most common dissimilar metals found together in a plumbing system. In closed systems, such as a chilled or heating water piping, the use of dissimilar metals may not create a serious problem; this is because there is virtually no oxygen in the water and corrosion relations tend to be stifled. Where dissimilar metals must be used, some codes require that they should be separated by dielectric union or a similar type of fitting. The effectiveness depends upon; distance between the metals on the electromotive -force series (EMF) chart, ratio of cathode to anode area, degree of aeration, amount of agitation, temperature, presence of dissolved salts, and other factors. U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ABBREVIATED EMF SERIES (Electromotive -Force Series; Common Piping Materials in Sea Water) CATHODE ( +) Passive GOLD — Fixtures, Faucets, Plating PLATINUM SILVER — Brazing alloys, Silver- bearing solders TITANIUM — Condenser tubes MONEL (67% Ni - 33% Cu) — Specialty piping & equipment CUPRO- NICKEL — Condensers, Marine, Nuclear COPPER — Pressure, DWV, Gases, Air, Refrigeration, etc. BRASS (85/15 - Red) — Cast fittings, Valves BRASS (70/30 - Yellow) — Gas - cocks, Fittings, Connectors LEAD — Solder, Pipe, Sheet, Coating, Lining TIN — Solders, Coating, Lining CAST IRON — Pressure, DWV WROUGHT IRON — Pressure MILD STEEL — Fire Protection ALUMINUM — Refrigeration, Irrigation, some Solar GALVANIZED STEEL —Pressure, DWV ZINC — Coatings, Linings, some Fittings MAGNESIUM — Water Heater Anodes, Cathodic protection for pipelines ANODE ( -) Active; Sacrificial Material 5. Dezincification is a type of corrosion in which brass dissolves as an alloy and the copper constituent redeposits from solution onto the surface of the brass as a metal, but in the porous form. The zinc constituent may be carried away from the brass as a soluble salt, or may be deposited in place as an insoluble compound. Dezincification is normally associated with brass valves where the zinc content exceeds 15 %. Generally, areas of high stress, such as valve stems and gate valve bodies, are primary targets of attack. 6. On rare occasion problems of corrosion by aggressive water, possibly aggravated by poor design or workmanship, do exist. Aggressive, hard well waters that cause pitting can be identified by chemical analysis and treated to bring their composition within acceptable limits. Typically these hard waters are found to have high total dissolved solids (t.d.s.) including sulfates and chlorides, a pH in the range of 7.2 to 7.8, a high content of carbon dioxide (CO2) gas (over 10 parts per million, ppm), and the presence of dissolved oxygen (D.O.) gas. Soft acidic waters can cause the annoying problem of green staining of fixtures or "green water ". Raising the pH of such waters to a value of about 7.2 or more usually solves the problem, but a qualified water treatment specialist should be consulted. 7. Aggressive soil conditions can be a cause for external corrosion of copper piping systems. Non - uniform soil characteristics, such as different soil aeration, resistivity, or moisture properties, between adjacent sections of tube can create galvanic corrosion cells. Soils contaminated with high concentrations of road salts or fertilizers containing ammonia, chlorides, and nitrogen are known to combine with water to form acids. Any metal pipe laid in ash or cinders is subject to attack by the acid generated when sulfur compounds combine with water to form sulfuric acid. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Copper Tube Fittings continued 1. Soldering Clearance (between the outside of the tube and the inside diameter of the solder cup) and the Depth of the Solder Cup (into which the tube is inserted). Soldering Nominal Maximum Size I. D. of of Fitting Fittin (Inches) Inch ( Minimum 0. D. of Tube Inch (mm) or• p D epth Maximum Clearance for Solderin Inch (mml Depth of Solder Cup Inch (mm) 1/4 0.381 (9.66) 0.374 (9.50) 0.007 (0.18) 0.31 (7.9) 3/8 0.506 (12.85) 0.499 (12.67) 0.007 (0.18) 0.38 (9.7) 112 0.631 (16.03) 0.622 (15.85) 0.009 (0.18) 0.50 (12.7) 5/8 0.756 (19.20) 0.749 (19.02) 0.007 (0.18) 0.62 (15.7) 3/4 0.881 (22.38) 0.872 (22.20) 0.009 (0.18) 0.75 (19.1) 1 1.132 (28.75) 1.123 (28.54) 0.008 (0.216) 0.91 (23.1) 11/4 1.382 (35.10) 1.373 (34.88) 0.008 (0.216) 1 0.97 (24.6) 11/2 1.633 (41.48) 1.623 (41.22) 0.010 (0.25) 1 .09 (27.1) 2 2.133 (54.18) 2.123 (53.92) 0.010 (0.25) 1.34 (34.0) 2112 2.633 (66.88) 2.623 (66.62) 0.010 (0.25) 1.47 (37.3) 3 3.133 (79.58) 3.123 (79.32) 0.010 (0.25) 1.66 (42.2) 31/2 3.633 (92.28) 3.623 (92.02) 0.010 (0.25) 1.91 (48.5) 4 4.133 (104.98) 14.123 (104.72) 10.010 (0.25) 1 2.16 (54.9) 5 5.133 (130.38) 5.123 (130.12) 10.010 (0.25) 1 2.66 (67.6) 6 6.133 (155.78) 16.123 (155.52) 10.010 (0.25) 1 3.09 (78.5) The National Bureau of Standards Report BMS58, "Strength of Soft - Soldered Joints in Copper Tubing," reporting on tests conducted with 3 /+ -inch tubing and fitting, says "When the clearance is greater than 0.010 inch (0.25 mm), there is difficulty in filling the joint properly." 2. Depth of Solder Penetration drastically affects the breaking load of the joint. When there is too great a soldering clearance, there is no capillary flow to assure complete solder penetration As shown in the chart below, the holding power of the 3 /4 -inch joint is directly proportional to the depth of solder penetration. For example: If you get only one -third penetration, you get approximately one -third the strength needed to assure complete satisfaction. Chart 2 - Type K' /4" Tubing I i! c Solder penetration of one -third the cup depth - breaking load, approximately 2,100 lb. (955 kg) 2 m 02 6A 06 0.8 16 12 451 1181 IIS 4201 125f (30 DEPTH OF ONE INCt+1ES hnml 3W TO BE SURE OF PROPER TOLFRI It is apparent that all of the scientific apparatus used to test tube and fittings, according to the dimensions indicated in Chart 1, would be impractical to use on the job. It is therefore essential that you install tube and fittings manufactured by companies known to be dedicated to the highest quality control standards. Should you encounter a condition where there is difficulty in filling the joint properly, NIBCO will analyze the trouble without charge. Just send six inches of the tube, along with the fitting and our technicians will provide you with an authoritative report. U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Solder penetration of the entire cup depth - breaking load approximately 7,000 lb. (3175 kg) MEN NAM 0 MR, ME -Ii. � MEMOMME MMUMENE1 1910 SEE il - 11111" 1 =- rG1,C. . 4J.'114 02 6A 06 0.8 16 12 451 1181 IIS 4201 125f (30 DEPTH OF ONE INCt+1ES hnml 3W TO BE SURE OF PROPER TOLFRI It is apparent that all of the scientific apparatus used to test tube and fittings, according to the dimensions indicated in Chart 1, would be impractical to use on the job. It is therefore essential that you install tube and fittings manufactured by companies known to be dedicated to the highest quality control standards. Should you encounter a condition where there is difficulty in filling the joint properly, NIBCO will analyze the trouble without charge. Just send six inches of the tube, along with the fitting and our technicians will provide you with an authoritative report. U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Solder penetration of the entire cup depth - breaking load approximately 7,000 lb. (3175 kg) BRAZING Copper Water Tube Size (In Inches) 1' 1 Brazing" Filler Required Inches (mm) Torch Tip Drill Size o. For Estimating Purposes Acetylene Consumption Oxygen Pressure (Approx.) Acetylene Pressure (Approx.) C.F.H. (C.M.H.) PSI (kPa) PSI (kPa) 1/4 0.25 (6.4) 54 15.9 (0.5) 4 (27) 4 (27) 3/8 038 (9.7) 54 15.9 (0.5) 4 (27) 4 (27) 112 0.50 (12.7) 51 24.8 03 5 34) 5 34 5/8 0.62 (15.7) 51 24.8 (03) 5 (34) 5 (34) 3/4 1.00 (25.0) 51 24.8 (0.7) 5 (34) 5 (34) 1 1.60 41.0) 48 31.6 (0.9) 6 41) 6 (41) 11/4 2.00 (51.0) 48 31.6 (0.9) 6 (41) 6 (41) 11/2 2.60 (66.0) 44 38.7 (1.1) 7 (48) 7 (48) 2 4.40 112.0) 40 60.0 1.7) 7 48) 7 48) 2112 5.90 (150.0) 40 60.0 (1.7) 7 (48) 7 (48) 3 7.90 (200.0) 35 70.0 (2.0) 7' /2 (52) 7 (52) 31/2 10.50 207.0) 35 70.0 (2.0) 7' /2 (52 ) 712 52) 4 13.50 (343.0) 30 88.5 (2.5) 9 (62) 9 (62) 5 20.50 (521.0) 30 88.5 (2.5) 9 (62) 9 (62) 6 28.50 (724.0) 30 88.5 (2.5) 9 (62) 9 (62) 'Approximate consumption when brazing one cup of the fitting. Actual consumption depends on workmanship. For filler sizes shown, one pound of filler alloy provides 1,068 inches (27.13 mm) of I /winch wire or 475 inches (12,065 mm) of 3 /32 -inch wire. "/16-inch (1.59 mm) diameter wire; all other is 3 /32 -inch (2.38 mm) diameter. SOLDER AND Nom. Size Joint (In Inches) FLUX REQUIREMENTS Solder Required, LB (kg) General Use Drainage Use 1/4 0.097 - 3/8 0.159 - 1/2 0.261 - 5/8 0,389 - 3/4 0.548 - 1 0.856 - 1 1/4 1.115 1.2 0.5 1 112 1.480 1.4 (0.6) 2 2.380 1.5 (0.7) 2112 3.225 - 3 4.335 2.8 (1.3) 31/2 5.786 - 4 7.446 42 (1.9) 5 11.392 - 6 15.815 - 8 26.955 - Solder requirements in this table are based on estimate of weight of solder used to prepare 100 solder joints of sizes shown. Two (2) ounces (0.06 kg) of solder flux will be required for each pound (0.45 kg) of solder. U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. ^ ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Co pper Tube Fittings continued olning matenals at or above 593 °C Pressure - temperature ratings consistent with the materials and procedures employed. [Note (7)] GENERAL NOTE: For extremely low working temperatures in the 0 °F to 2007 range, it is recommended that a joint material melting at or above 10007 be employed [see Note (5)]. NOTES: (1) Standard water tube sizes per ASTM B 88 (2) ASTM B 32 Alloy Grade Sn50 (3) The Safe Drinking Water Act Amendment of 1986 prohibits the use of any solder having a lead content in excess of 0.2% in potable water systems. (4) ASTM B 32 Alloy Grade Sb5 (5) ASTM B 32 Alloy Grade E (6) ASTM B 32 Alloy Grade HB (7) These joining materials are defined as brazing alloys by the American Welding Society. (8) The solderjoint exceeds the strength of Types K, L & M tube in drawn and annealed tempers. (9) The solderjoint exceeds the strength of Types L & M tube in drawn temper and Type K tube in annealed temper. (10) The solderjoint exceeds the strength of Type M tube in drawn temper and Types L & K in annealed temper. (11) The solderjoint exceeds the strength of Type L tube in annealed temper. Nominal Size Joint Nominal Size Joint (In Inches) Temperature, °F ( °C)" I Pressure, PSI (BAR)" (In Inches) Temperature, °F ( °C) Pressure, PSI (BAR) 3/8, 1/2, 3/4, 1, 3/8, 1/2, 3/4, 1 73 (23) 200 (14) 1 1/4, 1 1/2, 2 100 (38) 175 (12) 140 (60) 160 (11) ASME 876.26 180 (82) 100 (7) 200 (93) 80 (5) U.S, customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 �, ,�� r ., „ P SI ( BAR Maximum Gauge Working Pressure for Standard Water Tube Sizes [Note (1)] , / though 1" 1 /4" through 2" 2 /2" through 4" 5" through 8" 10" to 12" Saturated Steam LB (kg) Joining Material Working Temperature 9 P °F °C PSI BAR PSI BAR PSI BAR PSI BAR PSI BAR All Sizes Alloy Sn50 100 38 200 (14) 175 (12) 150 (10) 135 (9) 100 (6) 50 -50 Tin -Lead solder 150 66 150 (10) 125 (9) 100 (7) 90 (6) 70 (5) [Notes (2), (3)] 200 93 100 (7) 90 6) 75 (5) 70 5) 50 3 15 250 121 85 6 75 5 50 3 45 3 40 3 Alloy Sb5 100 38 1090 "' (75) 850 11 (59) 705 "' (49) 660 m (46) 340 (23) 95 -5 Tin - Antimony solder 150 66 625j (43) 485 " (34) 405 ('q (28) 375 " (26) 280 (19 [Note (4)] 200 93 505 "" (35) 395 (27) 325 " (32) 1 305 " (21) 230 (16) 15 250 121 270 19 210 15 175 12 1 165 11 120 8 Alloy E 100 38 710 (49 ) 555(' (38) 460 (32) 430 ") (30) 320 22 150 66 475P (33) 370 "°' (26) 305 ( (21) 285 (20) 215 (15) 200 93 375 (26) 290 (20) 240"" (17) 225"" (16) 170 (12) 15 250 121 320 (22) 250 (17) 205 (14) 195 (13) 145 (9) Alloy HB 100 38 1035 "' (71) 805 0 (56) 670 (46) 625 "' (43) 340 (23) [Note (6)] 150 66 710j F4 9) 555 " (38) 460 ") (32) 430 00 ' (30) 320 (22) 15 200 93 440 /n (30) 345 nn (24) 285 n„ (20) 2 65 "n (18) 200 (14) J" 250 121 430 (30) 335 "" (23) 275 ( (19) 260 "" (18) 195 (13) olning matenals at or above 593 °C Pressure - temperature ratings consistent with the materials and procedures employed. [Note (7)] GENERAL NOTE: For extremely low working temperatures in the 0 °F to 2007 range, it is recommended that a joint material melting at or above 10007 be employed [see Note (5)]. NOTES: (1) Standard water tube sizes per ASTM B 88 (2) ASTM B 32 Alloy Grade Sn50 (3) The Safe Drinking Water Act Amendment of 1986 prohibits the use of any solder having a lead content in excess of 0.2% in potable water systems. (4) ASTM B 32 Alloy Grade Sb5 (5) ASTM B 32 Alloy Grade E (6) ASTM B 32 Alloy Grade HB (7) These joining materials are defined as brazing alloys by the American Welding Society. (8) The solderjoint exceeds the strength of Types K, L & M tube in drawn and annealed tempers. (9) The solderjoint exceeds the strength of Types L & M tube in drawn temper and Type K tube in annealed temper. (10) The solderjoint exceeds the strength of Type M tube in drawn temper and Types L & K in annealed temper. (11) The solderjoint exceeds the strength of Type L tube in annealed temper. Nominal Size Joint Nominal Size Joint (In Inches) Temperature, °F ( °C)" I Pressure, PSI (BAR)" (In Inches) Temperature, °F ( °C) Pressure, PSI (BAR) 3/8, 1/2, 3/4, 1, 3/8, 1/2, 3/4, 1 73 (23) 200 (14) 1 1/4, 1 1/2, 2 100 (38) 175 (12) 140 (60) 160 (11) ASME 876.26 180 (82) 100 (7) 200 (93) 80 (5) U.S, customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 RATED WORKING ' COPPER Nominal Water Water Temperature Range Tube Size (In Inches) -20' to 1007 ( -29° to 38 °C) 150 °F (66 °C) 2001 (95 °C) 2507 (120 °C) 3007 (149 °C) 350 °F (177 °C) 4007 °C) (204 1/4 912 (62) 775 (53) 729 (50) 729 (50) 714 (49) 608 (42) 456 (31) 3/8 779 (54) 662 (46) 623 (43) 623 (43) 610 (42) 519 (36) 389 (27) 112 722 50) 613 42 577 (40) 577 (40) 565 (39) 481 33) 361 (25) 5/8 631 (43) 537 (37) 505 (35) 505 (35) 495 (34) 421 (29) 316 (21) 3/4 582 (40) 495 (34) 466 (32) 466 (32) 456 (31) 388 (27) 291 (20) 1 494 34) 420 (29) 395 (27) 395 27) 387 (26) 330 23) 247 17) 11/4 439 (30) 373 (26) 351 (24) 351 (24) 344 (23) 293 (20) 219 (15) 11/2 408 (28) 347 (24) 327 (23) 327 (23) 320 (22) 272 (19) 204 (1 4) 2 364 25) 309 21) 291 (20) 291 20) 285 (20) 242 17) 182 13 2112 336 (23) 285 (20) 269 (19) 269 (19) 263 (18) 224 (15) 168 (12) 3 317 (22) 270 (19) 254 (17) 254 (17) 248 (17) 211 (15) 159 (11) 31/2 304 (21 ) 258 (18 ) 243 (17) 243 (17 ) 238 (16) 202 14) 152 (10 4 293 (20) 249 (17) 235 (16) 235 (16) 230 (16) 196 (13) 147 (10) 5 269 (19) 229 (16) 1 215 (15) 1 215 (15) 211 (15) 179 (12) 135 (9) 6 251 (17) 213 (15) 201 (14) 1 196 (14) 167 (12) 125 (8) 8 270 (19) 230 (16) 216 (15) 1 216 (15) 212 (15) 180 (12) 135 (9) fhe fitting pressure rating applies to the largest opening of the fitting. Nominal Size Joint (In Inches) 112, 3/4,1,1 1/4, 1112, 2, 21 12, 3, 4, 5, 6, 8 (also 10" for Class 125) Temperature t ( ) " 0 -150 (0 -61 175 (79) 200 (93) 250 275 300 Class 150" ` 225 (15) 220 (15) 210 (15) 205 (14) 195 (13) 190 (13) 180 (12) 165 11) 150 (10) 406 (208) "MSS SP -106 a ASTM 8584, UNS C83800 and UNS C84400 ASTM B62, UNS C83600 and ASTM 8584, UNS C83600 Class 125" e 105 (7) 100 (7) 95 (7) 90 (6) 90 (6) 85 (6) 85 (6) 75 (5) 70 (5) Pressure (PSI) Class 150 210 (14) 205 (14) 195 (13) 190 (13) 180 (12) 175 (12) 170 (12) 150 (10) 140 (9) U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART,IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 17 Copper Water Tube The mechanics of making both the solder joint and the brazing joint are comparatively similar. Complete instructions on proper techniques of both of these joining methods are outlined in this catalog on pages 85 -97. A very important consideration in Copper Piping is the selection of the proper bonding medium. As a general rule, the working temperature of the installation is a more important consideration than the working pressures. If the working temperature is not over 250 °F (121 °C), either 50 -50 %* or 95 -5% solder can be used successfully. However, if the temperature exceeds 2507 (1 21 °C), a low temperature brazing alloy should be used, with a melting temperature somewhat in excess of 1000 °F (538 °C). According to BMS report No. 58, joints made with tin or tin -alloy solders should not be subject continuously to temperatures above 250 *F (121 °C). A number of brazing alloys are available and a careful study should be made in every case to determine the proper alloy for the particular application. "The Safe Drinking Water Act Amendment of 1986 prohibits the use in potable water systems of any solder having a lead content in excess of 0.2 %. DIMENSIONAL Nominal Water Tube Size (In Inches) DATA SOLDER 1 1 Solder Joint Fittings - Tolerances Male End (Fitting Connector) Female End (Solder Cup) Diameter Diameter Min. Max. Min. Max. Inch (mm) Inch (mm) Inch (mm) Inch (mm) Solder Joint Fittings Copper Alloy - Pressure' Z Fitting End Length Solder Cup Length Min. Min. Inch (mm) Inch (mm) Solder Joint Fittings Copper Alloy - Drainage' ' Fitting End Length Solder Cup Length Min. Min. Inch (mm) Inch (mm) 1/8 0.248 (6.30) 0.251 (6.38) 0.252 (6.40) 0.256 (6.50) 0.31 (7.9) 0.25 (6.4) N/A N/A N/A N/A 1/4 0.373 (9.47) 0.376 (9.55) 0.377 (9.58) 0.381 (9.68) 0.38 (9.7) 0.31 (7.9) N/A N/A N/A N/A 3/8 0.497 (12.62) 0.501 (12.73) 0.502 (12.75) 0.506 (12.85) 0.44 (11.2) 0.38 (9.7) N/A N/A N/A N/A 112 0.622 (15.80) 0.626 (15.90) 0.627 (15.93) 0.631 (16.03) 0.56 (14.2) 0.50 (12.7) N/A N/A N/A N/A 5/8 0.747 (18.97) 0.751 (19.08) 0.752 (19.10) 0.756 (19.20) 0.69 (17.5) 0.62 (15.7) N/A N/A N/A N/A 3/4 0.872 (22.15) 0.876 (22.25) 0.877 (22.28) 0.881 (22.38) 0.81 (20.6) 0.75 (19.1) N/A N/A N/A N/A 1 1.122 (28.50) 1.127 (28.63) 1.128 (28.65) 1.132 (28.75) 0.97 (24.6) 0.91 (23.1) N/A N/A N/A N/A 11/4 1.372 (34.85) 1.377 (34.98) 1.378 (35.00) 1.382 (35.10) 1.03 (26.2) 0.97 (24.6) 0.56 (14.2) 0.50 (12.7) 1112 1.621 (41.17) 1.627 (41.33) 1.628 (41.35) 1.633 (41.48) 1.16 (29.5) 1.09 (27.7) 0.62 (15.7) 0.56 (14.2) 2 2.121 (53.87) 2.127 (54.03) 2.128 (54.05) 2.133 (54.18) 1.41 (35.8) 1.34 (34.0) 0.69 (17.5) 0.62 (15.7) 2112 2.621 (66.57) 2.627 (66.73) 2.628 (66.75) 2.633 (66.88) 1.53 (38.9) 1.47 (37.3) N/A N/A N/A N/A 3 3.121 (79.27) 3.127 (79.43) 3.128 (79.45) 3.133 (79.58) 1.72 (43.7) 1.66 (42.2) 0.81 (20.6) 0 .75 (19.1) 31/2 3.621 (91.97) 3.627 (92.13) 3.628 (92.15) 3.633 (92.28) 1.97 (50.0) 1.91 (48.5) N/A N/A N/A N/A 4 4.121 (104.67) 4.127 (104.83) 4.128 (104.85) 4.133 (104.98) 2.22 (56.4) 2.16 (54.9) 1.06 (26.9) 1.00 (25.4) 5 5.121 (130.07) 5.127 (130.23) 5.128 (130.25) 5.133 (130.38) 2.72 (69.1) 2.66 (67.6) 1.31 (33.3) 1.25 (31.8) 6 6.121 (155.47) 6.127 (155.63) 6.128 (155.65) 3.133 (79.58) 3.22 (81.8) 3.09 (78.5) 1.62 (41.1) 1.50 (38.1) 8 8.119 (206.22) 8.127 (206.43) 8.128 (206.45) 8.133 (206.58) 4.09 (103.9) 3.97 (100.8) 2.12 (53.8) 2.00 (50.8) 10 10.119 (257.02) 10.127 (257.23) 10.128 (257.25) 10.133 (257.38) 4.12 (104.6) 4.00 (101.6) N/A N/A N/A N/A 12 12.119 (307.82) 12.127 (308.03) 12.128 (308.05) 12.133 (308.18) 4.62 (117.3) 4.50 (114.3) N/A N/A N/A N/A 'As shown Standard ASME B16.18 ' As shown Standard ASME 816.22 'As shown Standard ASME B16.23 'As shown Standard ASME 816.29 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 DIMENSIONAL Nominal Water Tube Size (In Inches) DATA •A 1 Male End (Fitting Connector) Diameter Min. Max. Inch (mm) Inch (mm) Inch Female End (Brazing Cup) Diameter Min. Max. (mm) Inch (mm) Fitting End Length Min. Inch (mm) Solder Cup Length Min. Inch (mm) 1/4 0.373 (9.47) 0.376 (9.55) 0.377 (9.58) 0.381 (9.68) 0.23 (5.8) 0.17 (4.3) 3/8 0.497 (12.62) 0.501 (12.73) 0.502 (12.75) 0.506 (12.85) 0.26 (6.6) 0.20 (5.1) 112 0.622 (15.80) 0.626 (15.90) 0.627 (15.93) 0.631 (16.03) 0.28 (7.1) 0.22 (5.6) 5/8 0.747 (18.97) 0.751 (19.08) 0.752 (19.10) 0.756 (19.20) N/A N/A N/A N/A 3/4 0.872 (22.15) 0.876 (22.25) 0.877 (22.28) 0.881 (22.38) 0.31 (7.9) 0.25 (6.4) 1 1.122 (28.50) 1.127 (28.63) 1.128 (28.65) 1.132 (28.75) 0.34 (8.6) 0.28 (7.1) 11/4 1.372 (34.85) 1.377 (34.98) 1.378 (35.00) 1.382 (35.10) 0.37 (9.4) 0.31 (7.9) 1112 1.621 (41.17) 1.627 (41.33) 1.628 (41.35) 1.633 (41.48) 0.40 (10.2) 0.34 (8.6) 2 2.121 (5187) 2.127 (54.03) 2.128 (54.05) 2.133 (54.18) 0.47 (11.9) 0.40 (10.2) 2112 2.621 (66.57) 2.627 (66.73) 2.628 (66.75) 2.633 (66.88) 0.53 (13.5) 0.47 (11.9) 3 3.121 (79.27) 3.127 (79.43) 3.128 (79.45) 3.133 (79.58) 0.59 (15.0) 0.53 (13.5) 31/2 3.621 (91.97) 3.627 (92.13) 3.628 (92.15) 3.633 (92.28) 0.65 (16.5) 0.59 (15.0) 4 4.121 (104.67) 4.127 (104.83) 4.128 (104.85) 4.133 (104.98) 0.72 (18.3) 0.64 (16.3) 5 5.121 (130.07) 5.127 (130.23) 5.128 (130.25) 5.133 (130.38) 0.81 (20.6) 0.73 (18.5) 6 6.121 (155.47) 6.127 (155.63) 6.128 (155.65) 3.133 (79.58) 0.94 (23.9) 0.83 (21.1) 8 8.119 (206.22) 8.127 (206.43) 8.128 (206.45) 8.133 (206.58) 1.28 (32.5) 1.17 (29.7) 10 10.119 (257.02) 10.127 (257.23) 10.128 (257.25) 10.133 (257.38) N/A N/A N/A N/A 12 12.119 (307.82) 12.127 (308.03) 12.128 (308.05) 1 12.133 (308.18) N/A N/A N/A N/A ' In accordance with MS SP -73 U.S. customary units in this document are the standard; the metric units are provided for reference only The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. ^ IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Copper Water Tube continued DIMENSIONAL Nominal Water Tube Size (In Inches) DATA COPPER Outside Diameter Inch (mm) Tolerances (Hard Drawn Only) Tubing OD Min. Max. Inch (mm) Inch (mm) TYPE "K" Hard Drawn: Soft Annealed: Usage: 20 -ft. (6.1m) Straight Lengths 20 -ft. (6.1 m) Straight Lengths, or 40 -ft. (12.2m) and 60 -ft. (18.3m) Length Coils (to and including size 1 1/2) For underground service and general purpose plumbing and heating installations under severe conditions. Nominal Wall Thickness Inch (mm) Weight Per Foot Lb (kg) Hard Drawn Bursting Safe Working Pressure" Pressure' psi (bars) psi (bars) Soft Annealed Bursting Safe Working Pressure" Pressure` psi (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) 0.035 (0.89) 0.145 (0.07) N/A N/A 1612 (111) N/A N/A 913 (63) 3/8 0.500 (12.70) 0.497 (12.62) 0.501 (12.73) 0.049 (1.24) 0.269 (0.12) N/A N/A 1675 (115) N/A N/A 960 (66) 112 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.049 (1.24) 0.344 (0.16) 9840 (678) 1337 (92) 4535 (313) 758 (52) 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) 0.049 (1.24) 0.418 (0.19) N/A N/A 1104 (76) N/A N/A 626 (43) 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.065 (1.65) 0.641 (0.29) 9300 (641) 1278 (88) 4200 (290) 724 (50) 1 1.125 (28.58) 1.122 (28.50) 1.127 (28.63) 0.065 (1.65) 0.839 (0.38) 7200 (496) 982 (68) 3415 (235) 557 (38) 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.065 (1.65) 1.040 (0.47) 5525 (381) 797 (55) 2800 (193) 452 (31) 1112 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.072 (1.83) 1.360 (0.62) 5000 (345) 742 (51) 2600 (179) 420 (29) 2 2.125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.083 (2.11) 2.060 (0.93) 3915 (270) 652 (45) 2235 (154) 370 (26) 2112 2.625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.095 (2.41) 2.930 (1.33) 3575 (246) 597 (41) N/A N/A 338 (23) 3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.109 (2.77) 4.000 (1.81) 3450 (238) 578 (40) N/A N/A 328 (23) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (92.13) 0.120 (3.05) 5.120 (2.32) N/A N/A 549 (38) N/A N/A 311 (21) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.134 (3.40) 6.510 (2.95) 3415 (235) 540 (37) N/A N/A 306 (21) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.160 (4.06) 9.670 (4.39) 3585 (247) 517 (36) N/A N/A 293 (20) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.192 (4.88) 13.900 (6.30) 3425 (236) 520 (36) N/A N/A 295 (20) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.271 (6.88) 25.900 (11.75) 3635 (251) 553 (38) N/A N/A 314 (22) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.338 (8.59) 40.300 (18.28) N/A N/A 553 (38) N/A N/A 314 (22) 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.405 (10.29) 57.800 (26.22) N/A N/A 555 (38) N/A N/A 1 314 (22) Note: Information and data contained in these charts, as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanicaljoints. "Based on actual laboratory test data provided by Copper Development Association, Inc. ° Based upon 1501 (65.6 °C) with an allowable stress of 9500 psi (668 kPa). Based upon 150 °F (65.6 °C) with an allowable stress of 5100 psi (359 kPa). U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 DIMENSIONAL Nominal Water Tube Size (In Inches) DATA - COPPER Outside Diameter Inch (mm) Inch WATER TUBE - TYPE Tolerances (Hard Drawn Only) Tubing OD Min. Max. (mm) Inch (mm) "L" TYPE 1" Hard Drawn: Soft Annealed: Usage: 20 -ft. (6.1m) Straight Lengths 20 -ft. (6.1m) Straight Lengths, or 40 -ft. (12.2m) and 60 -ft. (18.3m) Length Coils (to and including size 1 1/2) For general purpose plumbing and heating conditions. Nominal Wall Thickness Inch (mm) Weight Per Foot Lb (kg) Hard Drawn Bursting Safe Working Pressure" Pressure' psi (bars) psi p (bars) Soft Annealed Bursting Safe Working Pressure" Pressure` psi (bars) p (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) 0.030 (0.76) 0.126 (0.06) N/A N/A 1367 (94) N/A N/A 775 (53) 3/8 0.500 (12.70) 0.497 (12.62) 0.501 (12.73) 0.035 (0.89) 0.198 (0.09) N/A N/A 1168 (81) N/A N/A 662 (46) 112 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.040 (1.02) 0.285 (0.13) 7765 (535) 1082 (75) 3885 (268) 613 (42) 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) 0.042 (1.07) 0.362 (0.16) N/A N/A 947 (65) N/A N/A 537 (3� 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.045 (1.14) 0.455 (0.21) 5900 (407) 873 (60) 2935 (202) 495 (34) 1 1.125 (28.58) 1.122 (28.50) 1.127 (28.63) 0.050 (1.27) 0.655 (0.30) 5115 (353) 741 (51) 2650 (183) 420 (29) 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.055 (1.40) 0.884 (0.40) 4550 (314) 658 (45) 2400 (165) 373 (26) 1112 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.060 (1.52) 1.140 (0.52) 4100 (283) 613 (42) 2200 (152) 347 (24) 2 2.125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.070 (1.78) 1.750 (0.79) 3365 (232) 545 (38) 1910 (132) 309 (21) 2112 2.625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.080 (2.03) 2.480 (1.12) 3215 (222) 504 (35) N/A N/A 285 (20) 3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.090 (2.29) 3.330 (1.51) 2865 (198) 476 (33) N/A WA 270 (19) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (92.13) 0.100 (2.54) 4.290 (1.95) N/A N/A 455 (31) N/A N/A 258 (18) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104,83) 0.110 (2.79) 5.380 (2.44) 2865 (198) 440 (30) N/A N/A 249 (17) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.125 (3.18) 7.610 (3.45) 2985 (206) 404 (28) N/A N/A 229 (16) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.140 (3.56) 10.200 (4.63) 2690 (185) 376 (26) N/A N/A 213 (15) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.200 (5.08) 19.290 (8.75) 2650 (183) 406 (28) N/A N/A 230 (16) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.250 (6.35) 30.100 (13.65) N/A N/A 407 (28) N/A N/A 231 (16) 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.280 (7.11) 140.400 (18.33) N/A N/A 380 (26) N/A N/A 215 (15) Note: Information and data contained in these charts, as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanicaljoints. "Based on actual laboratory test data provided by Copper Development Association, Inc. ° Based upon 150 °F (65.6 °C) with an allowable stress of 9500 psi (668 kPa). Based upon 150 °F (65.6 °C) with an allowable stress of 5100 psi (359 kPa). U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST - ELKHART, IN 46516 -4740 • USA • PH: 1,800,234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Copper Water Tubecontinued DIMENSIONAL Nominal Water Tube Size (In Inches) DATA COPPER Outside Diameter Inch (mm) Inch Tolerances (Hard Drawn Only) Tubing OD Min. Max. (mm) Inch (mm) TYPE "M" Hard Drawn Only: 20 -ft. (6.1m) Straight Lengths Usage: For general purpose plumbing, heating and drainage installations. Nominal Wall Thickness Inch (mm) Weight Per foot Lb (kg) g) Hard Drawn Bursting Safe Working Pressure" Pressure' psi p (bars) psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) N/A N/A N/A N/A N/A N/A N/A N/A 3/8 0.500 (12.70) 0.497 (12.62) 0.501 (12.73) 0.025 (0.64) 0.145 (0.07) N/A N/A 855 (59) 112 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) 0.028 (0.71) 0.204 (0.09) 6135 (423) 741 (51) 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) N/A N/A N/A N/A N/A N/A N/A N/A 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) 0.032 (0.81) 0.328 (0.15) 4717 (325) 611 (42) 1 1.125 (28.58) 1.122 (28.50) 1.127 (28.63) 0.035 (0.89) 0.465 (0.21) 3865 (266) 506 (35) 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.042 (1.07) 0.682 (0.31) 3875 (267) 507 (35) 1112 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.049 (1.24) 0.940 (0.43) 3550 (245) 497 (34) 2 2.125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.058 (1.47) 1.460 (0.66) 2935 (202) 448 (31) 2112 2.625 (66.68) 2.621 (66.57) 2.627 (66.73) 0.065 (1.65) 2.030 (0.92) 2800 (193) 411 (28) 3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.072 (1.83) 2.680 (1.22) 2665 (184) 380 (26) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (92.13) 0.083 (2.11) 3.580 (1.62) N/A N/A 378 (26) 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.095 (2.41) 4.660 (2.11) 2215 (153) 377 (26) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.109 (2.77) 6.660 (3.02) 2490 (172) 349 (24) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.122 (3.10) 8.920 (4.05) 2000 (138) 328 (23) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.170 (4.32) 16.500 (7.48) 2285 (158) 344 (24) 10 10125 (257.18) 10.119 (257.02) 10.127 (257.23) 0.212 (5.38) 25.600 (11.61) N/A N/A 344 (24) 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) 0.254 (6.45) 36.700 (16.65) N/A N/A 345 (24) Note: Information and data contained in these charts, as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanicaljoints. "Based on actual laboratory test data provided by Copper Development Association, Inc. ° Based upon 150 °F (65.6 °C) with an allowable stress of 9500 psi (668 kPa). U.S. customary units in this document are the standard; the metric units are provided for reference only The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 TYPE "DWV" Hard Drawn Only: 20 -ft. (6.1m) Straight Lengths Usage: For drain, waste, vent and other non - pressure applications. Nominal Water Tube Size (In Inches) Outside Diameter Inch (mm) Tolerances (Hard Drawn Only) Tubing OD Min. Max. Inch (mm) Inch (mm) Nominal Wall Thickness Inch (mm) Weight Per Foot Lb (kg) Hard Drawn Bursting Pressure' psi (bars) 1/4 0.375 (9.53) 0.373 (9.47) 0.376 (9.55) N/A N/A N/A N/A N/A N/A 3/8 0.500 (12.70) 0.497 (12.62) 0.501 (12.73) N/A N/A N/A N/A N/A N/A 112 0.625 (15.88) 0.622 (15.80) 0.626 (15.90) N/A N/A N/A N/A N/A N/A 5/8 0.750 (19.05) 0.747 (18.97) 0.751 (19.08) N/A N/A N/A N/A N/A N/A 3/4 0.875 (22.23) 0.872 (22.15) 0.876 (22.25) N/A N/A N/A N/A N/A N/A 1 1.125 (28.58) 1.122 (28.50) 1.127 (28.63) N/A N/A N/A N/A N/A N/A 11/4 1.375 (34.93) 1.372 (34.85) 1.377 (34.98) 0.040 (1.02) 0.650 (0.29) N/A N/A 1112 1.625 (41.28) 1.621 (41.17) 1.627 (41.33) 0.042 (1.07) 0.809 (0.37) 440 (30) 2 2.125 (53.98) 2.121 (53.87) 2.127 (54.03) 0.042 (1.07) 1.070 (0.49) 326 (22) 2112 2.625 (66.68) 2.621 (66.57) 2.627 (66.73) N/A N/A N/A N/A N/A N/A 3 3.125 (79.38) 3.121 (79.27) 3.127 (79.43) 0.045 (1.14) 1.690 (0.77) 239 (16) 31/2 3.625 (92.08) 3.621 (91.97) 3.627 (92.13) N/A N/A N/A N/A N/A N/A 4 4.125 (104.78) 4.121 (104.67) 4.127 (104.83) 0.058 (1.47) 2.870 (1.30) 225 (16) 5 5.125 (130.18) 5.121 (130.07) 5.127 (130.23) 0.072 (1.83) 4.430 (2.01) 227 (16) 6 6.125 (155.58) 6.121 (155.47) 6.127 (155.63) 0.083 (2.11) 6.100 (2.77) 223 (15) 8 8.125 (206.38) 8.119 (206.22) 8.127 (206.43) 0.109 N/A 10.600 (4.81) 219 (15) 10 10.125 (257.18) 10.119 (257.02) 10.127 (257.23) N/A N/A N/A N/A N/A N/A 12 12.125 (307.98) 12.119 (307.82) 12.127 (308.03) N/A N/A N/A N/A N/A N/A Note: Information and data contained in these charts, as taken from ASTM Specifications B 88. Rated internal pressure for copper water tube based on the strength of the tube alone and applicable to systems using suitable mechanicaljoints. "Based on actual laboratory test data provided by Copper Development Association. Inc. e Based upon 150 °F (65.6 °C) with an allowable stress of 9500 psi (668 kPa). `Based upon 150 °F (65.6 °C) with an allowable stress of 5100 psi (359 kPa). U.S. customary units in this document are the standard; the metric units are provided for reference only The values stated in each system are not exact equivalents. DWV Tube is for sanitary drainage applications. The tubing wall is thinner than Type "M" - making it both lighter and less expensive. Research indicates that DWV tube has a service life of approximately 100 years - considerably longer than any building in which it might be installed. The advantages of copper systems are augmented in DWV installations. Its light weight makes handling and transportation easier - only 0.34 lb. (0.15 kg) for a 20 ft. (61 m) length of size 3. Its thinner wall allows faster soldering. These advantages offer an economical option without sacrificing stability or longevity for both contractor and the home owner. Further information will be furnished on request from NIBCO's Technical Services Department, at 1- 888 - 446 -4226 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455 Copper Water Tubecontinued Under normal conditions, the physical properties of copper tubes, when produced by responsible manufacturers are perfectly adapted for the conveyance of hot and cold water, steam, oil, gas, and air. Copper tubes will stand up under ordinary conditions, but the user is specifically cautioned against laying underground tube in cinderfill, especially if the ground is apt to be wet. Due to the sulphur compounds in the cinders, a condition of this kind may corrode the outside of the tubes. This may be overcome either by wrapping the tube with canvas and asphaltum or by surrounding the tube with a bed of clean sand mixed with lime, or with limestone or broken plaster. When conditions are doubtful, it is advisable to consult the Copper Development Association, or the tube manufacturer. Annealed copper tubes are generally recommended for underground use. '/2" annealed copper tubes have been frozen as many as six times before finally bursting, eight times for 1" size, and eleven times for 2" size. Hard drawn copper tubes, however, burst during the first freezing the same as iron pipe. (Condensed from Copper Tube Handbook.) COMPARATIVE DATA - COPPER WATER TUBE AND IRON PIPES BTUs to Raise 100 °F /38 °C Nominal "A "B" "C" "D" "E" 7" "G "H" Water New Pipe Inside Outside Weight Volume Water Pipe Heat Loss Flow Tube Size Diameter Diameter (In Inches) Inch (mm) Inch (mm) Lb (Kg) Gal /10ft. L /3.05m BTU kJ BTU kJ BTU kJ GPM LPM 3/8 Coper .430 (10.92) 0.500 (12.70) 0.198 (0.090) 0.0754 (0.2854) 62.89 (66.4) 18.61 (19.6) No Data No Data 1.873 (7.089) Iron .493 (12.52) 0.675 (17.15) 0.567 (0.257) 0.0992 (0.3755) 82.66 (87.2) 62.37 (65.8) No Data No Data 2.464 (9.326) 112 Coper .545 (13.84) 0.625 (15.88) 0,285 (0.129) 0.1212 (0.4587) 101.20 (106.8) 26.70 (28.2) 0.34 (0.36) 3.565 (13.494) Iron .622 (15.80) 0.840 (21.34) 0.850 (0.386) 0.1578 (0.5973) 131.60 (138.8) 93.50 (98.6) 5.94 (6.27) 4.585 (17.354) 3/4 Coper .785 (19.94) 0.875 (22.23) 0.455 (0.207) 0.2514 (0.9515) 209.60 (221.1) 42.67 (45.0) 0.41 (0.44) 9.599 (36.332) Iron .824 (20.93) 1.050 (26.67) 1.130 (0.513) 0.2770 (1.0484) 230.10 (242.8) 124.30 (131.1) 7.16 (7.55) 9.720 (36.790) 1 Coper 1.025 (26.04) 1.125 (28.58) 0.655 (0.297) 0.4287 (1.6226) 357.30 (317.0) 61.38 (64.8) 0.50 (0.53) 19.80 (74.94) Iron 1.049 (26.64) 1.315 (33.40) 1.678 (0.762) 0.4490 (1.6995) 374.30 (394.9) 184.58 (194.7) 8.62 (9.09) 18.53 (70.14) 11/4 Coper 1.265 (32.13) 1.375 (34.93) 0.884 (0.401) 0.6529 (2.4712) 544.30 (574.3) 82.91 (81.5) 0.62 (0.65) 35.05 (132.66) Iron 1.380 (35.05) 1.660 (42.16) 2.270 (1.031) 0.7770 (2.9409) 647.70 (683.4) 249.70 (263.4) 10.65 (11.24) 38.56 (145.95) 1112 Coper 1.505 (38.23) 1.625 (41.28) 1.140 (0.518) 0.9241 (3.4977) 770.40 (812.8) 107.16 (113.1) 0.69 (0.73) 56,16 (212.57) Iron 1.610 (40.89) 1.900 (48.26) 2.720 (1.235) 1.0580 (4.0045) 881.60 (930.1) 298.10 (314.5) 11.97 (12.63) 58.20 (220.29) 2 Coper 1.985 (50.42) 2.125 (53.98) 1.750 (0.795) 1.6080 (6.0863) 1340.00 (1413.8) 164.50 (173.6) 0.84 (0.89) 119.10 (450.79) Iran 2.067 (52.50) 2.375 (60.33) 3.650 (1.657) 1.7430 (6.5973) 1453.00 (1533.0) 401.50 (423.6) 14.61 (15.41) 113.50 (429.60) 2112 Coper 2.465 (62.61) 2.625 (66.68) 2.480 (1.126) 2.4790 (9.3830) 2066.00 (2119.7) 233.00 (245.8) 1.01 (1.07) 214.30 (811.13) Iron 2.469 (62.71) 2.875 (73.03) 5.790 (2.629) 2.4870 (9.4133) 2073.00 (2187.1) 636.90 (672.0) 17.42 (18.38) 182.50 (690.76) 3 Coper 2.945 (74.80) 3.125 (79.38) 3.330 (1.512) 3.5390 (13.3951) 2945.00 (3107.1) 313.20 (330.4) 1.13 (1.19) 347.40 (1314.91) Iron 3.068 (77.93) 3.5 (88.90) 7.58 (3.441) 3.8400 (14.5344) 3201.00 (3377.2) 832.70 (878.5) 20.63 (21.77) 326.00 (1233.91) 4 Coper 3.905 (99.19) 4.125 (104.78) 5.380 (2.443) 6.2220 (23.5503) 5186.00 (5471.5) 505.72 (533.6) 1.50 (1.58) 747.10 (2821.77) Iron 4.026 (102.26) 4.5 (114.30) 10.79 (4.899) 1 6.6130 (25.0302) 5513.00 (5816.5) 1186.90 (1252.2) 26.00 (27.43) 1 673.80 (2550.33) COLUMN A: The copper tube is Type L Standard, meeting the requirements of ASTM Specification B 88. The iron pipe is standard weight, schedule 40, bare pipe, except as to Column I where new galvanized pipe is referred to. COLUMN B: From manufacturers' specifications. Slight variations can be noted between specifications of different manufacturers, but these figures are representative. COLUMN C: From manufacturers' specifications with the same considerations as noted for Column B. COLUMN D: From manufacturers' specifications. COLUMN E: Cubic contents of 10 linear feet/3.05 linear metres of tube and have been calculated from dimeters given in Column B, by the formula for the contents of a cylinder. COLUMN F: This column has been calculated from Column E and shows the number of BTUs (kilojoules) required to heat the water content only of 10 feet (3.05 metres) of the given tube and pipe 100 °F (38 °C). It requires 833.6 BTUs (879.5 kJ) to heat 1 gallon (3.875 litres) of water 1007 (38 °C). COLUMN G: These figures are calculated from Column D and show the number of BTUs (kJ) required to raise the temperature of 10 feet (3.05 metres) of empty tube and pipe 1007 (38 °C). Due to difference in the specific heat of the materials, it requires 9.4 BTUs (9.9 IQ to raise 1 pound (0.454 kilograms) of copper 1007 (38 °C) and 11.0 BTUs (11.6 Q to raise 1 pound (0.454 kilograms) of iron 1007 (38 °C). COLUMN H: This column shows the heat emission from 10 feet (3.05 metres) of the given tube and pipe placed horizontally. The column in terms of BTUs lost per hour (kilojoules lost per hour) for each degree of difference in temperature between the pipe and the surrounding air. The figures for iron are taken from experimental data obtained at the Mellon Institute. Figures for copper have been calculated with reference to those for iron on the basis of the known ratio of heat emission between the two materials. COLUMN I: This column shows the number of gallons (lives) of water which will Flow through 100 feet (30.48 metres) of the given tube and pipe with a pressure loss of 10 pounds per square inch (70 kilopascals). Flow is based on diameters in Column B according to Professor Dawson's formulae for NEW galvanized iron pipe and NEW capper tube. Due to the corrosion of iron and its tendency to accumulate sediments and other foreign matter, Prof. Dawson suggests that 15% be deducted from the figures for iron pipe in order to arrive at a reasonable performance expectancy for such pipe in service. Because copper resists rust and is inherently more smooth, Professor Dawson suggests a deduction of only 5% from the figures given for copper tube. U.S. customary units in this document are the standard; the metric units are provided for reference only The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 In the majority of low- pressure heating systems employing copper tube and installed in small houses or private dwellings, provision for expansion and contraction is relatively simple. Mains, risers, and branches to radiators should be free or floating at one end of the line. Holes should be large enough to permit free movement of the tube, and care should be exercised so that pipe hangers and supports permit unrestricted movement and do not anchor the tube. Wrought copper tube hangers that are both practicable and neat in appearance are available. Unusually long runs of copper tubing should be provided with an expansion bend or loop. By bending soft temper copper tube, a simple form of expansion loop can be made. With the addition of combination flared -tube to solder joint fittings, as illustrated in Figure 1, these types of loops can be used when space or other limitations exist. The correct proportions of such expansion loop to meet various conditions are shown in the accompanying table. FIGURE 1 A P a. U -Bend r r L b. Coiled Loop ------------- c. Offset and A Return 8,45 010 z 040 a.33 Ia 631 = E am a sa U Z aai ¢o m 16 351 Z u am 25 E 15am d i3lt! X afa W 11S4J a 45 nm ■ ■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■ ■ME■■■■■■■■■EW■ ■■■■■■■■■■.M■■■ ■■■■■■■■WeA■■■■ ■ ■ ■ ■ ■ ■ ■��■■■ S NMENNEMENNOMON 'MMMMMIN TBAPEAATtEtE, `F PCII The above chart is calculated using 1 Oft (3.05m) of copper tubing as the reference point. You may use it as follows: 1 00ft (30.5m) of copper tube, with a 200 °F (93.3 °C) temperature change. Reference point .2256 inches for 1 Oft, (5.73mm for 3.05m), multipy by 10 for 1 00f (30.5m), resulting in an answer of 2.256 inches (57.3mm) of expansion or contraction. NOTE: Calculations for expansion and contraction should be based on the average coefficient of expansion of copper which is 0.0000094 per °F (0.00001692 per °C) between 77 °F and 212 °F (25 °C and 100 °C). For example, the expansion for each 1 Oft (3.05m) of any size of tube heated from room temperature of 707 (21.1 °C) to 170 °F (76.7 °C), that is, 100 °F (55.6 °C) rise, is: Rise Coefficient 100 °F x 1Oft X 12 inches x 0.000094 _ 0.1128 in. (55.6 °C) (3.05m) (1000mm) (0.00001692) - (2.87mm) RADII OF Nominal Tube Size COILED EXPANSION LOOPS AND DEVELOPED LENGTHS OF EXPANSION OFFSETS Expected Expansion 1/2 1 1112 2 21/2 3 31/2 4 R L R L R L R L R L R L R L R L Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) 1/4 6 (152.4) 38 (965.2) 9 (228.6) 54 (1311.6) 11 (279.4) 66 (1676.4) 12 (304.8) 77 (1955.8) 14 (355.6) 86 (2184.4) 15 (381.0) 94 (2381.6) 16 (4064) 102 (2590.8) 17 (431.8) 109 (2768.6) 3/8 7 (177.8) 44 (1117.6) 10 (254.0) 63 (1600.2) 12 (304.8) 77 (1955.8) 14 (355.6) 89 (2260.6) 16 (406,4) 99 (2514.6) 17 (431.8) 109 (2168.6) 19 (482.6) 117 (2911.8) 20 (508.0) 126 (3200.4) 1/2 8 (203.2) 50 (1270.0) 11 (119.4) 70 (1118.0) 14 (355.6) 89 (2260.6) 16 (406.4) 99 (2514.6) 18 (4572) 111 (2819.4) 19 (482.6) 122 (3098.8) 21 (533.4) 131 (3327.4) 22 (558.8) 140 0556.0) 3/4 9 (228.6) 59 (1498.6) 13 (330.2) 83 (2108.2) 16 (406.4) 101 (2565.4) 19 (482.Q 117 (2911.8) 21 (533.4) 131 (3327.4) 23 (584.2) 143 (3632.4 25 (635.0 155 (3937.0) 26 (660.4) 166 (4216.4) 1 11 (219.4) 67 (1701.8) 15 (381.0) 94 (2387.6) 18 (457.4 115 (2921.0) 21 (533.4) 133 (3378.4 24 (609.6) 149 (3784.0 26 (660.4) 163 (4140.4 28 (711.) 176 (4410.4) 30 9620) 188 (4775.21 1 1/2 13 030.2) 80 (2032.0) 18 (457.2) 113 (2870.2) 22 (558.6) 138 (3505.2) 25 (635.) 160 (4064.0) 6) 179 (4546.6) 31 (181.4) 1% (4978.4) 34 (863.6) 212 (5384.8) 36 (914.4) 226 (5740.4) 2 15 (381.0) 91 (2311.4) 21 (533.4) 129 (3276.6) 25 (635.0) 158 (4013.71 29 (736.6) 163 (46482) 2) 205 (5207.0) 36 (914.4) 224 (5689.6) 39 (990.6) 242 (6146.8) 41 (1041.4) 259 (6578.6) 21/2 16 (406.4) 102 (2590.8) 23 (584.2) 144 (3657.0 28 RI 1.4 176 (4470.4) 32 (8128) 203 (5156.71 4) 227 (5165.8) 40 (1016.0) 249 (6324.6) 43 (1092.4 269 (6832.6) 46 (11664) 288 U315A 3 18 (457.2) 111 (1819.4) 25 (635.0) 157 (3987.8) 30 962.0 191 (4851.4) 35 (889.0 222 (5638.8) P36O14.4) 0) 248 (6299.2) 43 (1092.2) 272 (69068) 47 (1193.8) 293 (/4422) 50 (1270.0) 314 (7975.6) 31/2 19 (4826) 120 (30460) 27 (685.8) 169 (42926) 33 (838.2) 206 (5232.4) 38 (965.1 239 (6070.6) 2) 267 (6781.8) 47 (1193.8) 293 9442.2) 50 (1270.0 316 (8026.4) 54 (1371.0 338 (8585.2) 4 20 (508.0 128 0251.4 29 (136.6) 180 (4572.0 35 (689.0 220 (5588.0 41 (1041.4) 255 (6477.0 .0 285 Q239.0) 50 (1210.0) 312 Q924.8) 54 (1311.6) 3 (8559.8) 51 (1441.8) 361 (9169.4) 5 23 (584.2) 142 (3606.8) 32 (812.8) 201 (5105.4) 39 �J90.6) 245 (6223.0) 45 (1143.0 284 (7213.6) .4) 318 (&177.2) 55 (1397.0) 348 (8839.) 60 (1524.0 376 (9550.4) 64 (1625.6) 402(10210.8) U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.95.3455 25 75 135 175 225 375 325 { -am (2391 01 (M40 047n 0550 "4251 Copper Water Tube,ontinued I: The smooth interior of copper tube, and the design of both solder joint and flared- tube -type fittings, which have no shoulders projecting into the flow of water, decrease friction loss. With the use of copper tube, no allowance is necessary for the accumulation of rust deposits in supply and service lines. Consequently, copper tube lines are usually figured one size smaller than iron pipe for the same service. This rule does not apply to lines from a well to a pump where the nominal diameters specified by the pump manufacturer must be adhered to strictly. Water passing through any pipe line encounters resistance by friction. The resistance is increased by bends and turns in the line, which should be taken into account in complex piping systems. For example, a one -inch 90° elbow will cause friction loss equivalent to that of one foot (0.305m) of straight one -inch tube. (See below for allowance to be made for fittings and valves in equivalent lengths of tube.) Friction loss in terms of head loss must be taken into consideration in calculating tube sizes to be used for various types of installations. For most average- size -house installations with water pressures 40 PSI (275.8kPa) and higher, 3/4„ copper tube will be ample for main supply lines, and '12" copper tube can be used for risers and branches to all fixtures. The smaller 3 /8" tube is adequate to supply branches, but with pressures at 40 PSI (275.8kPa) and higher, water hammer becomes a concern when the flow is suddenly stopped. APPROXIMATE Nominal Tube Size (In Inches) FRICTION i Wrought- Copper Fittings 90° 45° Tee Tee 90° 180° Elbow Elbow Run Side Outlet Bend Bend Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) Cast Copper Alloy Fittings and Valves 45° Tee Tee Comp. Globe Gate Elbow Run Side Outlet Stop Valve Valve Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) 3/8 0.5 (0.15) 0.5 (0.15) 0.5 (0.15) 1 (0.31) 0.5 (0.15) 0.5 (0.15) L2(O.61) 0.5 (0.15) 0.5 (0.15) 2 (0.61) 9 (2.75) - - - - 112 0.5 (0.15) 0.5 (0.15) 0.5 (0.15) 1 (0.31) 0.5 (0.15) 1 (0.31) 0.5 (0.15) 0.5 (0.15) 2 (0.61) 13 (3.97) - - - - 5/8 0.5 (0.15) 0.5 (0.15) 0.5 (0.15) 2 (0.61) 1 (0.31) 1 (0.31) 1 (0.31) 0,5 (0.15) 3 (0.92) 17 (5.19) - - - - 3/4 1 (0.31) 0.5 (0.15) 0.5 (0.15) 2 (0.61) 1 (0.31) 2 (0.61) 2 (0.61) 1 (0.31) 0.5 (0.15) 3 (0.92) 21 (6.41) - - - - 1 1 (0.31) 1 (0.31) 0.5 (0.15) 3 (0.92) 2 (0.61) 2 (0.61) 4 (1.22) 2 (0.61) 0.5 (0.15) 5 (1.53) 30 (9.15) - - 1 (0.31) 11/4 2 (0.61) 1 (0.31) 0.5 (0.15) 4 (122) 2 (0.61) 3 (0.92) 5 (1.53) 2 (0.61) 1 (0.31) 7 (2.14) - - 53 (16.17) 1 (0.31) 1112 2 (0.61) 2 (0.61) 1 (0.31) 5 (1.53) 2 (0.61) 4 (1.22) 8 (2.44) 3 (0.92) 1 (0.31) 9 (2.75) - - 66 (20.13) 2 (0.61) 2 2 (0.61) 2 (0.61) 1 (0.31) 7 (2.14) 3 (0.92) 8 (2.44) 11 (3.36) 5 (1.53) 2 (0.61) 12 (3.66) - - 90 (27.45) 2 (0.61) 2112 2 (0.61) 3 (0.92) 2 (0.61) 9 (2.75) 4 (1.22) 16 (4.88) 14 (4.27) 8 (2.44) 2 (0.61) 16 (4.88) - - - - 2 (0.61) 3 3 (0.92) 4 (1.22) - - - - 5 (1.53) 20 (6.10) 18 (5.49) 11 (3.36) 2 (0.61) 20 (6.10) - - - - 2 (0.61) 31/2 4 (1.22) - - - - - - 7 (2.14) 24 (1.32) 24 (7.32) 14 (4.27) 2 (0.61) 31 (9.46) - - - - 2 (0.61) 4 - - - - - - - - 8 (2.44) 28 (8.54) 28 (8.54) 17 (5.19) 2 (0.61) 37 (11.29) - - - - 2 (0.61) 5 - - - - - - - - 10 (3.05) 37 (11.29) 41 (12.51) 22 (6.71) 2 (0.61) 48 (14.64) - - - - - - 6 - - - - - - - - 13 (3.97) 47 (14.34) 52 (15.86) 28 (8.54) 2 (0.61) 61 (18.61) - - - - - - Notes: This table is based on tests conducted at Harvard University (1948). If the type of fitting is not known - i.e., whether wrought copper or cast alloy -use cast copper alloy values for design. U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800,234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455 1 112 550 (37.92) Service Temperature °F ( °C) 370 (25.51) 410 (28.27) 1 340 (23.44) 270 (18.62) 100 °F (37.8 °C) 200 °F (93.3 °C) 300 °F (148.9 °C) 400 °F (204.4 °C) Nominal S = 6000psi (414 bars) S = 4800psi (331 bars) S =4700 psi (324 bars) S =3000 psi (207 bars) Tube Size 345 (23.79) 305 (21.03) 230 (15.86) 190 112 450 (31.03) (In Inches) Type K Type L I Type M Type K Type L Type M Type K I Type L Type K I Type L 1/4 1210 (83.43) 1025 90.67) - - 850 (58.61) 700 (48.27) - - 830 (57.23) 690 (47.58) 530 (36.54) 450 (31.03; 3/8 1275 (87.91) 890 (61.31) 625 (43.09) 930 (64.12) 630 (43.44) 460 (31.72) 910 (62.74) 610 (42.06) 590 (40.68) 400 (27.58; 1/2 1005(69.29) 810 (55.85) 560 (38.61) 730 (50.33) 580 (39.99) 415 (28.61) 1 720 (49.64) 570 (39.30) 460 (31.72) 1370 (25.51; 5/8 1830 (57.23) 705 (48.61) - - 600 (41.31) 1 500 (34.48) - - 1 580 (39.99) 500 (34.48) 380 (26.20) 1330 (22.75; 1 112 550 (37.92) 455 (31.37) 370 (25.51) 410 (28.27) 1 340 (23.44) 270 (18.62) 400 (27.58) 330 (22.75) 260 (17.93) 1220 2 485 (33.44) 405 (27.92) 335 (23.10) 350 (24.13) 310 (21.37) 240 (16.55) 345 (23.79) 305 (21.03) 230 (15.86) 190 112 450 (31.03) 375 (25.86) 305 (21.03) 330 (22.75) 275 (18.96) 220 (15.17) 320 (22.06) 270 (18.62) 210 (14.48) 180 3 430 (29.65) 355 (24.48) 280 (19.31) 320 (22.06) 260 (17.93) 205 (14.13) 315 (21.72) 255 (17.58) 210 (14.48) 170 1/2 410 (28.27) 340 (23.44) 280 (19.31) 300 (20.69) 250 (17.24) 200 (13.79) 300 (20.69) 245 (16.89) 190 (13.10) 160 4 400 (27.58) 325 (22.41) 280 (19.31) 295 (20.34) 240 (16.55) 200 (13.79) 290 (20.00) 235 (16.20) 190 (13.10) 150 5 385 (26.55) 300 (20.69) 260 (17.93) 290 (20.00) 220 (15.17) 190 (13.10) 280 (19.31) 215 (14.82) 180 (12.41) 140 6 385 (26.55) 280 (19.31) 240 (16.55) 280 (19.31) 205 (14.13) 180 (12.41) 280 (19.31) 200 (13.79) 190 (13.10) 130 8 410 (28.27) 300 (20.69) 255 (17.58) 300 (20.69) 220 (15.17) 190 (13.10) 300 (20.69) 215 (14.82) 200 (13.79) 140 10 410 (28.27) 300 (20.69) 255 (17.58) 310 (21.37) 225 (15.51) 190 (13.10) 305 (21.03) 220 (15.17) 200 (13.79) 150 12 410 (28.27) 280 (19.31) 225 (15.51) 310 (21.37) 210 (14.48) 190 (13.10) 305 (21.03) 205 (14.13) 200 (13.79) 140 'Rated internal pressures for Copper Water Tube based on the strength of the tube alone and applicable to systems using suitable mechanicaljoints. The values are based on the formula in the American Standard Code, Power Piping ANSI /ASME B31.1 1992. Formulas PD tm= 2S +0.8P +C or P_ 2 S tm When C is 0 D -0.8tm tm Minimum tube wall thickness P Maximum rated internal working pressure D Outside diameter of tube S Allowable stress in material due to internal pressure at operating temperature c Allowance for threading, mechanical strength and /or corrosion U.S. customary units in this document are the standard; the metric units are provided for reference only The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Hazen Wi I I iams Formula Maximum O.D. = 0.3760 inches (9.550 mm) Nominal O.D. = 0,3750 inches (9.525 mm) Minimum O.D. = 0.3740 inches (9.499 mm) Nominal I.D. = 0.3050 inches (7.747 mm) Nominal Wall Thickness = 0.0350 inches (0.089 mm) Flow Area = 0.0731 sq. inches (47.14 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocit (m /sec 0.50 3.77 8.81 2.20 32 0.85 8.81 0.67 1.00 13.62 31.77 4.39 63 3.08 31.77 1.34 1.50 28.86 67.27 6.59 95 6.53 67.27 2.01 2.00 49.17 114.54 8.78 126 11.12 114.54 2.68 2.50 74.33 173.08 10.98 158 16.81 173.08 3.35 3.00 1 104.18 242.51 1 13.17 1 189 1 23.57 1 242.51 4.02 3.50 138.60 322.54 15.37 221 31.35 32154 4.68 4.00 177.49 412.92 17.57 252 40.15 412.92 5.35 4.50 220.75 513.46 19.76 284 1 49.94 513.46 6.02 5.00 268.32 623.96 21.96 315 60.70 623.96 6.69 Hazen Williams Formula Maximum O.D. = 0.3760 inches (9.550 mm) Nominal O.D. = 0.3750 inches (9.525 mm) Minimum O.D. = 0.3740 inches (9.499 mm) Nominal I.D. = 0.3150 inches (8.001 mm) Nominal Wall Thickness = 0.0300 inches (0.076 mm) Flow Area = 0.0779 sq. inches (50.28 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 0.50 3.22 7.53 2.06 32 0.73 7.53 0.63 1.00 11.64 27.16 4.12 63 2.63 27.16 1.25 1.50 24.67 57.50 6.18 95 5.58 57.50 1.88 2.00 42.02 97.90 8.23 126 9.51 97.90 2.51 2.50 6153 147.94 10.29 158 14.37 147.94 3.14 3.00 89.05 207.28 12.35 189 20.14 207.28 3.76 3.50 118.47 275.69 14.41 221 26.80 275.69 4.39 4.00 151.71 352.94 16.47 252 34.32 352.94 5.02 4.50 188.68 438.87 18.53 284 42.68 438.87 5.65 5.00 229.34 533.32 20.58 315 51.88 533.32 6.27 Hazen Williams Formula Maximum O.D. = 0.5010 inches (12.725 mm) Nominal O.D. = 0.5000 inches (12.100 mm) Minimum O.D. = 0.4990 inches (12.674 mm) Nominal I.D. = 0.4020 inches (10.210 mm) Nominal Wall Thickness = 0.0490 inches (1.244 mm) Flow Area = 0.1269 sq. inches (81.89 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 Ft) Head Loss (ft/100 ft) Velocity (ft /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 1.00 3.55 8.29 2.53 63 0.80 8.29 0.77 1.50 7.53 17.55 3.79 95 130 17.55 1.16 2.00 12.83 29.89 5.06 126 2.90 29.89 1.54 2.50 19.39 45.16 6.32 158 4.39 45.16 1.93 3.00 27.18 63.28 7.58 189 6.15 63.28 2.31 3.50 36.16 84.16 8.85 221 8.18 84.16 2.70 4.00 46.31 107.74 10.11 252 10.48 107.74 3.08 4.50 57.60 133.97 11.37 284 13.03 133.97 3.47 5.00 70.01 162.80 12.64 315 15.84 162.80 3.85 5.50 83.52 194.19 13.90 347 18.89 194.19 4.24 6.00 98.13 228.11 1517 379 22.20 228.11 4.62 6.50 113.81 264.51 16.43 410 25.74 264.51 5.01 7.00 130.55 303.38 17.69 442 29.53 303.38 5.39 7.50 148.34 344.68 18.96 473 33.56 344.68 5.78 8.00 167.18 388.40 20.22 505 37.82 388.40 6.16 8.50 187.04 434.49 21.49 536 42.31 434.49 6.55 9.00 207.93 482.96 22.75 568 47.03 482.96 6.93 9.50 229.83 1 533.76 24.01 599 51.99 1 533.76 7.32 10.00 252.73 1 586.89 1 25.28 1 631 57.17 1 586.89 7.70 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST- • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 TYPE COPPER " 1 1 FRICTION LOSS 11 FEET Maximum O.D. = 0.5010 inches (12.725 mm) Nominal O.D. = 0.5000 inches (12.700 mm) Minimum O.D. = 0.4990 inches (12.675 mm) Nominal I.D. = 0.4500 inches (10.211 mm) Nominal Wall Thickness = 0.0350 inches (0.889 mm) Flow Area = 0.1590 sq. inches (102.61 sq, mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 1.00 2.56 5.97 2.21 63 0.58 5.97 0.67 1.50 5.43 12.65 3.31 95 1.23 12.65 1.01 2.00 9.24 21.54 4.42 126 2.09 21.54 1.35 2.50 13.98 32.54 5.52 158 3.16 32.54 1.68 3.00 19.59 45.60 6.63 189 4.43 45.60 2.02 3.50 26.06 60.65 7.73 221 5.90 60.65 2.36 4.00 33.37 77.64 8.84 252 7.55 77.64 2.69 4.50 41.51 96.54 9.94 284 9.39 96.54 3.03 5.00 50.45 117.32 11.05 315 11.41 117.32 3.37 5.50 60.19 139.94 12.15 347 13.62 139.94 3.70 6.00 70.72 164.38 13.26 379 16.00 164.38 4.04 6.50 82.01 190.62 14.36 410 18.55 190.62 4.38 7.00 94.08 218.63 15.46 442 21.28 218.63 4.71 7.50 106.90 248.40 16.57 473 24.18 248.40 5.05 8.00 120.48 279.90 17.67 505 2725 279.90 5.39 8.50 134.79 313.12 18.78 536 1 30A9 313.12 1 5.72 9.00 149.84 1 348.04 19.88 568 1 3190 348.04 6.06 9.50 1 165.62 1 384.65 20.99 599 1 37.47 384.65 6.40 10.00 182.13 422.94 2209 , 631 1 41.20 422.94 6.73 COPPER " ' 1 AND FRICTION LOSS II FEET Maximum O.D. = 0.5010 inches (12.725 mm) Nominal O.D. = 0.5000 inches (12.700 mm) Minimum O.D. = 0.4990 inches (12.675 mm) Nominal I.D. = 0.4020 inches (10.211 mm) Nominal Wall Thickness = 0.0250 inches (0.635 mm) Flow Area = 0.1269 sq, inches (81.89 sq. mm) Ha7Bn Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec 1.00 2.05 4.79 2.02 63 0.46 4.79 0.61 1.50 4.35 10.14 3.03 95 0.98 10.14 0.92 2.00 7.41 17.26 4.03 126 1.68 17.26 1.23 2.50 11.20 26.09 5.04 158 2.53 26.09 1.54 3.00 15.70 36.55 6.05 189 3.55 36.55 1.84 3.50 20.89 48.61 7.06 221 4.73 48.61 2.15 4.00 26.75 62.23 8.07 252 6.05 62.23 2.46 4.50 3127 77.39 9.08 284 7.53 77.39 2.77 5.00 40.44 94.04 10.09 315 9.15 94.04 3.07 5.50 48.25 112.17 11.09 347 10.91 112.17 3.38 600 56.68 131.76 12.10 379 12.82 131.76 3.69 6.50 65.74 152.79 13.11 410 14.87 152.79 4.00 7.00 75.41 175.25 14.12 442 17.06 175.25 4.30 7.50 85.69 199.10 15.13 473 19.38 199.10 4.61 8.00 96.57 224.35 16.14 505 21.84 224.35 4.92 8.50 108.04 250.98 17.15 536 24.44 250.98 5.23 9.00 120.11 1 278.97 18.16 568 27.17 278.97 5.53 9.50 1 132.76 1 30832 19.16 599 30.03 308.32 5.84 10.00 1 145.99 1 339.01 20.17 631 1 33.02 1 339.01 6.15 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS ' 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.514.295.3221 • FAX: +1.574.295.3455 COPPER WATER AND FRICTION LOSS PER 100 FEET Maximum O.D. = 0.626 inches (15.900 mm) Nominal O.D. = 0.6250 inches (15.875 mm) Minimum O.D. = 0.624 inches (15.850 mm) Nominal I.D. = 0.527 inches (13.3858 mm) Nominal Wall Thickness = 0.049 inches (1.245 mm) Flow Area = 0.2181 sq. inches (140.73 sq, mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (f /100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 1.00 0.95 2.22 1.47 63 0.22 2.22 0.45 1.50 2.02 4.70 2.21 95 0.46 4.70 0.67 2.00 3.44 8.00 2.94 126 0.78 8.00 0.90 2.50 5.19 12.10 3.68 158 1.18 12.10 1.12 3.00 7.28 16.95 4.41 189 1.65 16.95 1.34 3.50 9.69 22.54 5.15 221 2.19 22.54 1.57 4.00 12.40 28.86 5.88 252 2.81 28.86 1.79 4.50 15.43 35.88 6.62 284 3.49 35.88 2.02 5.00 18.75 43.61 7.35 315 4.24 43.61 2.24 5.50 22.37 52.01 8.09 347 5.06 52.01 2.47 6.00 2628 61.10 8.83 379 5.95 61.10 2.69 6.50 30.48 70.85 9.56 410 6.90 70.85 2.91 7.00 34.97 81.26 10.30 442 7.91 81.26 3.14 7.50 39.73 92.32 11.03 473 8.99 92.32 3.36 8.00 44.78 104.03 11.77 505 10.13 104.03 3.59 8.50 50.10 116.38 12.50 536 11.33 116.38 3.81 9.00 55.69 129.36 13.24 568 12.60 129.36 4.03 9.50 61.56 142.97 13.97 599 13.93 1 142.97 4.26 10.00 67.69 157.20 14.71 631 15.31 157.20 4.48 10.50 74.10 172.05 15.44 662 16.76 172.05 4.71 11.00 80.76 187.51 16.18 694 18.27 187.51 4. 11.50 87.69 203.58 16.91 725 19.84 203.58 5.16 12.00 94.88 220.26 17.65 757 21.46 220.26 5.38 12.50 102.34 1 237.54 1 18.39 789 23.15 237.54 5.60 13.00 110.05 255.41 19.12 820 24.89 255.41 5.83 13.50 118.01 273.89 1 19.86 852 26.70 273.89 6.05 14.00 126.23 292.95 1 20.59 1 883 28.56 1 292.95 6.28 Hazen Williams Formula Maximum O.D. = 0.626 inches (15.900 mm) Nominal O.D. = 0.6250 inches (15.875 mm) Minimum O.D. = 0.624 inches (15.850 mm) Nominal I.D. = 0.5450 inches (13.843 mm) Nominal Wall Thickness = 0.049 inches (1.245 mm) Flow Area = 0.2333 sq. inches (150.50 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (fV100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 1.00 0.81 1.89 1.38 63 0.18 1.89 0.42 1.50 1.71 3.99 2.06 95 039 3.99 0.63 2.00 2.92 6.80 2.75 126 0.66 6.80 0.84 2.50 4.41 10.27 3.44 158 1.00 10.27 1.05 3.00 6.18 14.39 4.13 189 1.40 14.39 1.26 3.50 8.23 19.14 4.81 221 1.86 19.14 1.47 4.00 10.53 24.51 5.50 252 2.38 24.51 1.68 4.50 1310 30.47 6.19 284 2.96 30.47 1.89 5.00 15.92 37.03 6.88 315 3.60 37.03 2.10 5.50 19.00 44.17 7.56 347 4.30 44.17 2.31 6.00 22.32 51.89 8.25 379 5.05 51.89 2.52 6.50 25.89 60.17 8.94 410 5.86 60.17 2.72 7.00 29.70 69.01 9.63 442 6.72 69.01 2.93 7.50 33.74 78.41 10.31 473 7.63 78.41 3.14 8.00 38.03 88.35 11.00 505 8.60 88.35 3.35 8.50 42.55 98.83 11.69 536 9.62 98.83 3.56 9.00 47.30 109.86 12.38 568 10.70 109.86 3.77 9.50 52.28 121.41 13.07 599 11.83 121.41 3.98 10.00 57.49 133.50 13.75 631 13.00 133.50 4.19 10.50 62.92 146.11 14.44 662 14.23 146.11 4.40 11.00 68.59 159.24 15.13 694 15.51 159.24 4.61 11.50 74.47 172.89 15.82 725 16.85 172.89 4.82 12.00 80.58 187.05 1 16.50 1 757 1 18.23 1 187.05 5.03 12.50 86.91 201.73 17.19 789 19.66 201.73 5.24 13.00 93.46 216.91 17.88 820 21.14 216.91 5.45 13.50 10022 232.60 18.57 852 22.67 232.60 5.66 14.00 107.20 248.78 19.25 883 24.25 248.78 5.87 U.S. customary units in this document are the standard; the metric units are provided for reference only The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.514.295.3221 • FAX: +1.574.295.3455 COPPER i LOSS (' Maximum O.D. = 0.626 inches (15.900 mm) Nominal O.D. = 0.6250 inches (15.875 mm) Minimum O.D. = 0.624 inches (15.850 mm) Nominal I.D. = 0.5690 inches (14.4526 mm) Nominal Wall Thickness = 0.028 inches (0.711 mm) flow Area = 0.2543 sq. inches (164.05 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 1.00 0.66 1.53 1.26 63 0.15 1.53 0.38 1.50 1.39 3.24 1.89 95 0.31 3.24 0.58 2.00 2.37 5.51 2.52 126 0.54 5.51 0.77 2.50 3.58 8.33 3.15 158 0.81 8.33 0.96 3.00 5.01 11.67 3.79 189 1.13 11.67 1.15 3.50 6.67 15.52 4.42 221 1.51 15.52 1.35 4.00 8.54 19.87 5.05 252 1.93 19.87 1.54 4.50 10.62 24.71 5.68 284 2.40 24.71 1.73 5.00 12.91 30.03 6.31 315 2.92 30.03 1.92 5.50 15.41 35.82 6.94 347 3.48 35.82 2.12 6.00 18.10 42.07 7.57 379 4.09 42.07 2.31 6.50 20.99 48.79 8.20 410 4.75 48.79 2.50 7.00 24.08 55.96 8.83 442 5.45 55.96 2.69 7.50 27.36 63.57 9.46 473 6.19 63.57 2 .88 8.00 30.83 71.64 10.09 505 6.98 71.64 3.08 8.50 34.50 80.14 10.72 536 7.80 80.14 3.27 9.00 38.35 89.08 11.36 568 8.68 89.08 3.46 9.50 42.39 98.45 11.99 599 9.59 98.45 3.65 10.00 46.61 108.25 12.62 631 10.54 108.25 3.85 10.50 51.02 118.47 13.25 662 11.54 118.47 4.04 11.00 55.61 129.12 13.88 694 12.58 129.12 4.23 11.50 60.39 140.19 14.51 725 13.66 140.19 4.42 12.00 65.34 1 151.67 15.14 757 14.78 1 151.67 1 4.61 12.50 70.47 163.57 15.77 789 15.94 163.57 4.81 13.00 75.78 175.88 16.40 820 17.14 175.88 5.00 13.50 81.26 188.60 17.03 852 18.38 188.60 5.19 14.00 86.93 201.72 17.66 883 19.66 201.72 5.38 Hazen Williams Formula Maximum O.D. = 0.751 inches (19.075 mm) Nominal O.D. = 0.7500 inches (19.050 mm) Minimum O.D. = 0.749 inches (19.025 mm) Nominal I.D. = 0.6520 inches (16.5608 mm) Nominal Wall Thickness = 0.049 inches (1.245 mm) Flow Area = 0.3339 sq. inches (215.40 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 1.00 0.34 0.79 0.96 63 0.08 0.79 0.29 2.00 1.22 2.84 1.92 126 0.28 2.84 0.59 3.00 2.58 6.02 2.88 189 0.58 6.02 0.88 4.00 4.40 10.24 3.84 252 1.00 10.24 1.17 5.00 6.66 15.48 4.80 315 1.51 15.48 1.46 6.00 9.33 21.69 5.77 379 211 21.69 1.76 7.00 12.41 28.85 6.73 442 2.81 28.85 2.05 8.00 15.90 36.93 7.69 505 3.60 36.93 2.34 9.00 19.77 45.92 8.65 568 4.47 45.92 2.64 10.00 24.03 55.81 9.61 631 5.44 55.81 2.93 11.00 28.67 66.57 10.57 694 6.49 66.57 3.22 12.00 33.69 78.20 11.53 757 7.62 78.20 3.51 13.00 39.07 90.68 12.49 820 8.84 90.68 3.81 14.00 44.82 104.00 13.45 883 10.14 104.00 4.10 15.00 50.92 118.16 14.41 946 11.52 118.16 4.39 16.00 57.39 133.14 15.37 1009 12.98 133.14 4.69 17.00 64.21 148.95 16.34 1072 14.52 148.95 4.98 18.00 71.38 165.56 17.30 1136 16.15 165.56 5.27 19.00 78.89 182.98 18.26 1199 17.85 182.98 5.56 20.00 86.76 201.19 19.22 1262 19.63 201.19 5.86 21.00 94.96 220.19 20.18 1325 21.48 220.19 6.15 22.00 103.51 239.98 21.14 1388 23.41 239.98 6.44 U.S. customary units in this document are the standard; the metric units are provided for reference only The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 ' COPPER " 1 / AND FRICTION LOSS II FEET Maximum O.D = 0.751 inches (19.075 mm) Nominal O.D. = 0.7500 inches (19.050 mm) Minimum O.D. = 0.749 inches (19.025 mm) Nominal I.D. = 0.6660 inches (16.9164 mm) Nominal Wall Thickness = 0.042 inches (1.067 mm) Flow Area = 0.3484 sq. inches (224.75 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (fU100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 1.00 0.30 0.71 0.92 63 0.07 0.71 0.28 2.00 1.10 2.56 1.84 126 0.25 2.56 0.56 3.00 2.33 5.43 2.76 189 0.53 5.43 0.84 4.00 3.97 9.24 3.68 252 0.90 9.24 1.12 5.00 6.00 13.96 4.60 315 1.36 13.96 1.40 6.00 8.41 19.56 5.53 379 1.90 19.56 1.68 7.00 11.20 26.02 6.45 442 2.53 26.02 1.96 8.00 14.34 33.31 7.37 505 3.24 33.31 225 9.00 17.83 41.41 8.29 568 4.03 41.41 2.53 10.00 21.67 50.33 9.21 631 4.90 50.33 2.81 11.00 25.86 60.03 10.13 694 5.85 60.03 3.09 12.00 30.38 70.52 11.05 757 6.87 70.52 3.37 13.00 35.23 81.77 11.97 820 7.97 81.77 3.65 14.00 40.41 93.79 12.89 883 9.14 93.79 3.93 15.00 45.92 106.56 13.81 946 10.39 106.56 4.21 16.00 51.75 120.07 14.74 1009 11.71 120.07 4.49 17.00 57.90 134.32 15.66 1072 13.10 134.32 4.77 18.00 64.37 149.30 16.58 1136 14.56 14930 1 5.05 19.00 71.15 165.01 17.50 1199 16.09 165.01 5.33 20.00 78.24 181.43 18.42 1262 17.70 181.43 5.61 21.00 85.64 198.57 1934 1325 19.37 198.57 5.89 22.00 93.34 216.42 20.26 1388 21.11 216.42 6.18 COPPER " 1 1 AND FRICTION LOSS II FEET Maximum O.D. = 0.876 inches (22.250 mm) Nominal O.D. = 0.8750 inches (22.225 mm) Minimum O.D. = 0.874 inches (22.200 mm) Nominal I.D. = 0.7450 inches (18.923 mm) Nominal Wall Thickness = 0.065 inches (1.651 mm) Flow Area = 0.4359 sq. inches (281.24 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 2.00 0.64 1.49 1.47 126 0.14 1.49 0.45 4.00 2.30 5.35 2.94 252 0.52 5.35 0.90 6.00 4.88 11.34 4.42 379 1.10 11.34 1.35 8.00 8.31 19.30 5.89 505 1.88 19.30 1.79 10.00 12.56 29.17 7.36 631 2.84 29.17 2.24 12.00 17.61 40.87 8.83 757 3.98 40.87 2.69 14.00 23.42 54.36 10.30 883 5.30 54.36 3.14 16.00 30.00 69.59 11.78 1009 6.79 69.59 3.59 18.00 37.31 86.54 13.25 1136 8.44 86.54 4.04 20.00 45.35 105.16 14.72 1262 10.26 105.16 4.49 22.00 54.10 125.44 16.19 1388 12.24 125.44 4.94 24.00 63.56 147.34 17.66 1514 14.38 147.34 5.38 26.00 73.72 170.86 1914 , 1640 16.68 170.86 5.83 28.00 84.56 195.97 20.61 1766 1 19.13 1 195.97 6.28 30.00 96.09 222.65 22.08 1893 1 21.74 1 222.65 6.73 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA ' PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574295.3455 O" ER TUBE - WATER FLOW r ► FRICTION LOSS PER 100 FEET Maximum O.D. = 0.876 inches (22.250 mm) Nominal O.D. = 0.8750 inches (22.225 mm) Minimum O.D. = 0.874 inches (22.200 mm) Nominal I.D. = 0.7850 inches (19.939 mm) Nominal Wall Thickness = 0.045 inches (1.143 mm) Flow Area = 0.4840 sq, inches (312.25 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 2.00 0.4944 1.1517 1.3258 12617 0.1118 1.1517 0.4041 4.00 1.7846 4.1519 16516 25235 0.4037 4.1519 0.8082 6.00 3.7815 8.7905 3.9774 378.52 0.8554 8.7905 1.2123 8.00 6.4425 14.9675 5.3032 504.69 1.4573 14.9675 1.6164 10.00 93393 22.6169 6.6290 630.87 2.2031 22.6169 2.0205 12.00 13.6513 31.6896 7.9548 757.04 10880 31.6896 2.4246 14.00 18.1618 42.1472 9.2806 883.21 4.1083 42.1472 2.8287 16.00 23.2573 53.9578 10.6064 1009.39 5.2610 53.9578 3.2328 18.00 28.9264 67.0944 11.9322 1135.56 6.5434 67.0944 3 .6369 20.00 35.1590 81.5338 13.2580 1261.73 7.9532 81.5338 4.0 22.00 41.9465 97.2555 14.5838 1 1387.91 9.4886 1 97.2555 1 4.4452 24.00 49.2811 114.2412 15.9096 1514.08 11.1477 114.2412 4.8493 26.00 57.1557 132.4747 17.2354 1640.25 12.9290 132.4747 5.2534 28.00 65.5641 151.9408 18.5613 1766.43 14.8311 151.9408 5.6575 30.00 74.5002 172.6261 19.8871 1892.60 16.8525 172.6261 6.0616 Hazen Williams Formula Maximum O.D. = 0.876 inches (22.250 mm) Nominal O.D. = 0.8750 inches (22.225 mm) Minimum O.D. = 0.874 inches (22.200 mm) Nominal I.D. = 0.8110 inches (20.5994 mm) Nominal Wall Thickness = 0.032 inches (0.813 mm) Flow Area = 0.5156 sq. inches (333,27 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec. 2.00 0.42 0.98 1.24 126 0.10 0.98 0.38 4.00 1.52 3.54 2.48 252 0.34 3.54 0.76 6.00 3.23 7.50 3.73 379 0.73 7.50 1.14 8.00 5.50 12.11 4.97 505 1.24 1237 1.51 10.00 8.31 19.30 6.21 631 1.88 1930 1.89 12.00 11.65 27.04 7.45 757 2.64 27.04 2.27 14.00 15.50 35.97 8.70 883 3.51 35.97 2.65 16.00 19.85 46.05 9.94 1009 4.49 46.05 3.03 18.00 24.69 57.26 11.18 1136 5.58 57.26 3.41 20.00 30.00 69.58 12.42 1262 6.79 69.58 3.79 22.00 35.80 83.00 13.66 1388 8.10 83.00 1 4.16 24.00 42.06 97.49 14.91 1514 9.51 1 97.49 4.54 26.00 48.78 113.05 16.15 1640 11.03 113.05 4.92 28.00 55.95 129.66 17.39 1766 12.66 129.66 5.30 30.00 63.58 147.32 18.63 1 1893 14.38 147.32 5.68 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART. IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 COPPER 1 1 FRICTION LOSS PER II FEET Maximum O.D. = 1.1265 inches (28.613 mm) Nominal O.D = 1.1250 inches (28.575 mm) Minimum O.D. = 1.1235 inches (28.537 mm) Nominal I.D. = 0.9850 inches (25.273 mm) Nominal Wall Thickness = 0.0650 inches (1.651 mm) Flow Area = 0.7776 sq. inches (501.65 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 2.50 0.24 0.55 1.03 158 0.05 0.55 0.31 5.00 0.85 1.98 2.06 315 0.19 1.98 0.63 7.50 1.80 4.19 3.09 473 0.41 4.19 0.94 10.00 3.07 7.14 4.13 631 0.70 7.14 1.26 12.50 4.65 1038 5.16 789 1.05 10.78 1.57 15.00 6.51 1511 6.19 946 1.47 15.11 1.89 17.50 8.66 2010 7.22 1104 1.96 20.10 2.20 20.00 11.09 25.73 8.25 1262 2.51 25.73 2.52 22.50 13.80 31.99 9.28 1419 3.12 31.99 2.83 25.00 16.77 38.88 10.32 1577 3.79 38.88 3.14 27.50 20.01 46.37 11.35 1735 4.53 46.37 3.46 30.00 23.51 54.47 12.38 1893 5.32 54.47 3.77 32.50 27.27 63.17 13.41 2050 6.17 63.17 4.09 35.00 31.28 72.45 14.44 2208 7.08 72.45 4.40 37.50 35.54 82.31 15.47 2366 8.04 82.31 4.72 40.00 40.05 92.75 16.50 2523 9.06 92.75 5.03 42.50 44.81 103.76 17.54 2681 10.14 103.76 5.34 45.00 49.81 115.33 18.57 2839 11.27 115.33 5.66 47.50 55.06 127.47 19.60 2997 12.46 127.47 5.97 50.00 60.55 140.15 20.63 3154 13.70 140.15 6.29 52.50 66.27 153.39 21.66 3312 14.99 153.39 6.60 55.00 72.24 167.18 22.69 3470 16.34 167.18 6.92 ' COPPER " 1 1 FRICTION LOSS II FEET Maximum O.D. = 1.1265 inches (28.613 mm) Nominal O.D. = 1.1250 inches (28.575 mm) Minimum O.D. = 1.1235 inches (28.537 mm) Nominal l.0, = 1.0250 inches (26.035 mm) Nominal Wall Thickness = 0.0500 inches (1.270 mm) Flow Area = 0.8252 sq inches (532.36 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/ 100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 2.50 0.20 0,48 0.97 158 0.05 0.48 0.30 5.00 0.74 1.71 1.94 315 0.17 1.71 0.59 7.50 1.56 3.63 2.92 473 0.35 3.63 0.89 10.00 2.66 6.18 3.89 631 0.60 6.18 1.19 12.50 4.02 9.33 4.86 789 0.91 9.33 1.48 15.00 5.64 13.08 5.83 946 1.27 13.08 1.78 17.50 7.50 17.39 6.80 1104 1.70 17.39 2.07 20.00 9.60 22.27 7.78 1262 2.17 22.27 2.37 22.50 11.94 27.69 8.75 1419 2.70 27.69 2.67 25.00 14.52 33.65 9.72 1577 3.28 33.65 2.96 27.50 17.32 40.13 10.69 1735 3.92 40.13 3.26 30.00 20.35 47.14 11.66 1893 4.60 47.14 3.56 32.50 23.60 54.67 12.64 2050 5.34 54.67 3.85 35.00 27.07 62.70 13.61 2208 6.12 62.70 415 37.50 30.76 71.24 14.58 2366 6.96 71.24 4.44 40.00 34.66 80.27 15.55 2523 7.84 80.27 4.74 42.50 38.78 89.80 16.52 2681 8.77 89.80 5.04 45.00 43.11 99.81 17.50 2839 9.75 1 99.81 5.33 47.50 47.65 11031 18.47 2997 10.78 110.31 5.63 50.00 52.40 121.29 19.44 3154 11.85 121.29 5.93 52.50 57.36 132.75 20.41 1 3312 12.97 132.75 6.22 55.00 62.52 144.68 21.38 1 3470 14.14 144.68 6.52 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 ' COPPER " 1 1 AND FRICTION LOSS 11 FEET Maximum O.D. = 1.1265 inches (28.613 mm) Nominal O.D. = 1.1250 inches (28.575 mm) Minimum O.D. = 1.1235 inches (28.537 mm) Nominal I.D. = 1.0558 inches (26.797 mm) Nominal Wall Thickness = 0.0350 inches (0.889 mm) Flow Area = 0.8742 sq. inches (563.98 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m Head Loss (m /100 m) Velocity (m /sec.) 2.50 0.18 0.41 0.92 158 0.04 0.41 0.28 5.00 0.64 1.49 1.84 315 0.14 1.49 0.56 7.50 1.36 3.15 2.75 473 0.31 3.15 0.84 10.00 2.31 5.37 167 631 0.52 5.37 1.12 12.50 149 8.11 4.59 789 0.79 8.11 1.40 15.00 4.90 11.36 5.51 946 1.11 11.36 1.68 17.50 6.52 15.11 6.42 1104 1.47 15.11 1.96 20.00 8.34 19.35 7.34 1262 1.89 19.35 2.24 22.50 10.38 24.06 8.26 1419 2.35 24.06 2.52 25.00 12.61 29.24 9.18 1577 2.85 29.24 2.80 27.50 15.05 34.88 10.09 1735 3.40 34.88 3.08 30.00 17.68 40.97 11.01 1893 4.00 40.97 3.36 32.50 20.51 47.51 11.93 2050 4.64 47.51 3.64 35.00 23.52 54.49 12.85 2208 5.32 54.49 3.92 37.50 2633 61.91 13.76 2366 605 61.91 4.19 40.00 30.12 69.76 14.68 2523 6.81 69.76 4.47 42.50 33.70 78.04 15.60 2681 7.62 78.04 4.75 45.00 37.47 86.74 16.52 2839 8.47 86.74 5.03 47.50 41.41 95.87 17.43 2997 9.37 95.87 5.31 50.00 45.54 105.41 18.35 3154 10.30 105.41 5.59 52.50 49.84 115.37 19.27 3312 11.28 115.37 5.87 55.00 54.33 125.74 20.19 3470 12.29 125.74 6.15 COPPER " 1 1 AND FRICTION LOSS 11 FEET Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.3750 inches (34.925 mm) Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.2450 inches (31.623 mm) Nominal Wall Thickness = 0.0650 inches (1.651 mm) Flow Area = 1.2174 sq. inches (785.41 sq mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m Head Loss (m /100 m) Velocity (m /sec.) 5.00 0.29 0.67 1.32 315 0.06 0.67 0.40 10.00 1.03 2.40 2.64 631 0.23 2.40 0.80 15.00 2.19 5.08 3.95 946 0.49 5.08 1.20 20.00 3.73 8.65 5.27 1262 0.84 8.65 1.61 25.00 5.64 13.06 6.59 1577 1.27 13.06 2.0 30.00 7.90 18.30 7.91 1893 1.79 18.30 2.41 35.00 10.51 24.34 9.22 2208 2.38 24.34 2.81 40.00 13.46 31.17 10.54 2523 3.04 31.17 3.21 45.00 16.74 38.75 11.86 2839 3.79 38.75 3.61 50.00 20.35 47.09 13.18 3154 4.60 47.09 4.02 55.00 24.27 56.18 14.49 3470 5.49 56.18 4.42 60.00 28.52 65.99 15.81 3785 6.45 1 65.99 4.82 65.00 33.07 76.52 17.13 4101 7.48 76.52 5.22 70.00 37.94 87.76 18.45 4416 8.58 87.76 5.62 75.00 43.11 99.71 19.77 4732 9.75 99.71 6.02 80.00 48.58 112.35 21.08 5047 10.99 112.35 6.43 U.S. customary units in this document are the standard; the metric units are provided for reference only The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. - ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 COPPER WATER AND FRICTION LOSS PER 100 FEET Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.375 inches (34.925 mm) Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.265 inches (32.131 mm) Nominal Wall Thickness = 0.0550 inches (1.397 mm) Flow Area = 1.2568 sq. inches (810.85 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 5.00 026 0.62 1.28 315 0.06 0.62 0.39 10.00 0.96 2.22 2.55 631 0.22 2.22 0.78 15.00 2.02 4.70 3.83 946 0.46 4.70 1.17 20.00 3.45 8.00 5.11 1262 0.78 8.00 1.56 25.00 5.22 12.09 6.38 1577 1.18 12.09 1.95 30.00 7.31 16.94 7.66 1893 1.65 16.94 2.33 35.00 9.73 22.53 8.93 2208 2.20 22.53 2.72 40.00 12.45 28.84 10.21 2523 2.82 28.84 3.1 45.00 15.49 35.86 11.49 2839 3.50 35.86 3.50 50.00 18.83 43.58 12.76 3154 4.26 43.58 3.89 55.00 22.46 51.98 14.04 3470 5.08 51.98 4.28 60.00 26.39 61.06 15.32 3785 5.97 61.06 4.67 65.00 30.61 70.81 16.59 4101 6.92 70.81 5.D6 70.00 35.11 81.21 17.87 4416 7.94 81.21 5.45 75.00 39.89 92.27 19.15 4732 9.02 92.27 5.84 80.00 44.96 103.97 20.42 5047 10.17 103.97 6.22 Hazen Williams Formula Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.3750 inches (34.925 mm) Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.2910 inches (32.7914 mm) Nominal Wall Thickness = 0.0420 inches (1.061 mm) Flow Area = 1.3090 sq, inches (844.52 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/ 100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec. 5.00 0.24 0.56 1.23 315 0.05 0.56 0.37 10.00 0.87 2.01 2.45 631 0.20 2.01 0.75 15.00 1.83 4.26 3.68 946 0.41 4.26 1.12 20.00 3.12 7.25 4.90 1262 0.71 7.25 1.49 25.00 4.72 10.95 6.13 1577 1.07 10.95 1.87 30.00 6.62 15.34 7.35 1893 1.50 15.34 2.24 35.00 8.81 20.40 8.58 2208 1.99 20.40 2.61 40.00 11.28 26.12 9.80 2523 2.55 26.12 2.99 45.00 14.03 32.48 11.03 2839 3.17 32.48 3.36 50.00 17.05 39.47 12.25 3154 3.86 39.47 3.74 55.00 20.34 47.08 13.48 3470 4.60 47.08 4.11 60.00 23.90 55.31 14171 1 3785 5.41 55.31 4.48 65.00 27.72 64.14 15.93 4101 6.27 64.14 4.86 70.00 31.80 73.56 17.16 4416 7.19 73.56 5.23 75.00 36.13 83.57 18.38 4732 8.17 83.57 5.60 80.00 40.72 94.17 19.61 5047 9.21 94.17 5.98 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Hazen Williams Formula Maximum O.D. = 1.6270 inches (41.326 mm) Nominal O.D = 1.6250 inches (41.275 mm) Minimum O.D. = 1.6230 inches (41.224 mm) Nominal I.D. = 1.4810 inches (38.227 mm) Nominal Wall Thickness = 0.0720 inches (1.829 mm) Flow Area = 1.7227 sq. inches (1111.39 sq, mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m/sec .) 5.00 0.12 019 0.93 315 0.03 0.29 0.28 10.00 0.44 1.03 1.86 631 0.10 1.03 0.57 15.00 0.94 2.18 2.79 946 0.21 2.18 0.85 20.00 1.60 3.72 3.72 1262 0.36 3.72 1.14 25.00 2.42 5.61 4.66 1577 0.55 5.61 1.42 30.00 3.39 7.87 5.59 1893 0.77 7.87 1.70 35.00 4.52 10.46 6.52 2208 1.02 10.46 1.99 40.00 5.78 13.39 7.45 2523 1.31 13.39 2.27 45.00 7.19 16.65 838 2839 1.63 16.65 2.55 50.00 8.74 20.24 931 3154 1.98 20.24 2.84 55.00 10.43 24.14 10.24 3470 2.36 24.14 3.12 60.00 12.26 28.36 11.17 3785 2.77 28.36 3.41 65.00 14.21 32.88 12.11 4101 3.22 32.88 3.69 70.00 16.30 37.72 13.04 4416 3.69 37.72 3.97 75.00 18.53 42.85 13.97 4732 4.19 42.85 4.26 80.00 20.88 48.28 14.90 5047 4.72 48.28 4.54 85.00 23.36 54.01 15.83 5362 5.28 54.01 4.83 90.00 25.97 60.04 16.76 5678 5.87 60.04 5.11 95.00 28.70 66.35 17.69 5993 6.49 66.35 5.39 100.00 31.56 72.96 18.62 6309 7.14 72.96 5.68 105.00 34.55 79.85 19.56 6624 7.82 79.85 5.96 110.00 37.66 87.03 20.49 6940 8.52 87.03 6.24 115.00 40.89 1 94.49 1 21.42 7255 1 9.25 1 94.49 1 6.53 COPPER 1 1 FRICTION LOSS II FEET Maximum O.D. = 1.6270 inches (41.326 mm) Nominal O.D. = 1.6250 inches (41.275 mm) Minimum O.D. = 1.6230 inches (41.224 mm) Nominal I.D. = 1.5050 inches (37.6174 mm) Nominal Wall Thickness = 0.0600 inches (1.524 mm) Flow Area = 1.7789 sq. inches (1147.71 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) VelX (m /sec.) 5.00 0.11 0.26 0.90 315 0.03 0.26 0.27 10.00 0.41 0.95 1.80 631 0.09 0.95 0.55 15.00 0.87 2.02 2.71 946 0.20 2.02 0.82 20.00 1.48 3.44 3.61 1262 0.34 3.44 1.10 25.00 2.24 519 4.51 1577 0.51 519 1.37 30.00 3.14 7.27 5.41 1893 0.71 7.27 1.65 35.00 4.18 9.67 6.31 2208 0.94 9.67 1.92 40.00 5.35 12.39 7.21 2523 1.21 12.39 2.20 45.00 6.65 15.40 8.12 2839 1.50 15.40 2.47 50.00 8.09 18.72 9.02 3154 1.83 18.72 2.75 55.00 9.65 22.32 9.92 3470 2.18 22.32 3.02 60.00 11.33 26.22 10.82 3785 2.56 26.22 3.30 65.00 13.14 30.41 11.72 4101 2.97 30.41 3.57 70.00 15.08 34.88 12.62 4416 3.41 34.88 3.85 75.00 17.13 39.63 13.53 4732 3.88 39.63 4.12 80.00 19.31 44.65 14.43 5047 4.37 44.65 4.40 85.00 21.60 49.95 15.33 5362 4.89 49.95 4.67 90.00 24.01 55.52 16.23 5678 5.43 55.52 4.95 95.00 26.54 61.36 17.13 5993 6.00 61.36 5.22 100.00 29.19 67.47 18.03 6309 6.60 67.47 5.50 105.00 31.95 73.84 18.94 6624 7.23 73.84 5.77 110.00 34.82 80.48 19.84 6940 7.88 80.48 6.05 115.00 1 37.81 1 87.38 1 20.74 7255 1 8.55 1 87.38 6.32 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234,0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Hazen Williams Formula Maximum O.D. = 1.6270 inches (41.326 mm) Nominal O.D. = 1.6250 inches (41.275 mm) Minimum O.D. = 1.6230 inches (41.224 mm) Nominal I.D. = 1.5270 inches (38.7858 mm) Nominal Wall Thickness = 0.0490 inches (1.2446 mm) Flow Area = 1.8313 sq. inches (1181.50 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 5.00 0.11 0.25 0.88 315 0.02 0.25 0.27 10.00 0.38 0.89 1.75 631 0.09 0.89 0.53 15.00 0.81 1.88 2.63 946 0.18 1.88 0.80 20.00 1.38 3.20 350 1262 0.31 3.20 1.07 25.00 2.09 4.84 4.38 1577 0.47 4.84 1.33 30.00 2.93 6.78 5.26 1893 0.66 6.78 1.60 35.00 3.89 9.02 6.13 2208 0.88 9.02 1.87 40.00 4.98 11.54 7.01 2523 1.13 11.54 2.14 45.00 6.20 14.35 7.88 2839 1.40 14.35 2.40 %00 7.53 17.44 8.76 3154 1.70 17.44 2.67 55.00 8.99 20.80 9.64 3470 2.03 20.80 2.94 60A0 10.56 24.44 10.51 3785 2.39 24.44 3.20 65.00 12.25 28.34 11.39 4101 237 28.34 3.47 70.00 14.05 32.50 12.26 4416 3.18 32.50 3.74 75.00 15.96 36.92 13.14 4732 3.61 36.92 4.00 80A0 17.99 41.61 14.02 5047 4.07 41.61 4.27 85.00 20.13 46.55 14.89 5362 4.55 46.55 4.54 90.00 22.38 51.74 15.77 5678 5.06 51.74 4.81 95.00 24.73 57.18 16.64 5993 5.59 57.18 5.07 100.00 27.20 62.87 17.52 6309 6.15 62.87 5.34 105.00 2937 68.81 18.40 6624 6.73 68.81 5.61 110.00 32.45 74.99 19.27 6940 7.34 74.99 5.87 115.00 35.23 1 81.42 1 20.15 1 7255 7.97 1 81.42 1 6.14 Hazen Williams Formula Maximum O.D. = 2.1270 inches (54.026 mm) Nominal O.D. = 2.1250 inches (53.975 mm) Minimum O.D. = 2.1230 inches (53.924 mm) Nominal I.D. = 1.9590 inches (49.7586 mm) Nominal Wall Thickness = 0.0830 inches (2.1082 mm) Flow Area = 3.0141 sq. inches (1944.58 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (1kPa /100 m) Head Loss (m /100 m) Velocit (m /sec 10 0.11 0.26 1.06 631 0.03 0.26 0.32 20 0.41 0.95 2.13 1262 0.09 0.95 0.65 30 0.87 2.02 3.19 1893 0.20 2.02 0.97 40 1.48 3.43 4.26 2523 0.34 3.43 1.30 50 2.24 5.19 5.32 3154 0.51 519 1.62 60 3.14 7.27 639 3785 0.71 7.27 1.95 70 4.18 9.67 7.45 4416 0.95 9.67 2.27 80 5.35 12.38 8.52 5047 1.21 12.38 2.60 90 6.66 15.39 9.58 5678 1.51 15.39 2.92 100 8.09 18.71 10.64 6309 1.83 18.71 3.24 110 9.66 22.32 11.71 6940 218 22.32 3.57 120 11.34 26.21 12.77 7570 2.57 26.21 3.89 130 13.16 30.40 13.84 8201 2.98 30.40 4.22 140 15.09 34.86 100 8832 3.41 34.86 4.54 150 17.15 39.61 15.97 9463 3.88 39.61 4.87 160 1933 44.63 17.03 10094 4.37 44.63 5.19 170 21.62 49.93 18.10 10725 4.89 49.93 5.52 180 1 24.04 1 55.50 1 19.16 11356 5.44 55.50 5.84 190 26.57 61.34 20.22 11986 6.01 61.34 6.16 200 29.22 67.44 21.29 1 12617 6.61 67.44 6.49 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Hazen Williams Formula Maximum O.D. = 2.1270 inches (54.026 mm) Nominal O.D. = 2.1250 inches (53.975 mm) Minimum O.D. = 2.1230 inches (53.924 mm) Nominal I.D. = 1.9850 inches (50.419 mm) Nominal Wall Thickness = 0.0700 inches (1.778 mm) Flow Area = 3.0946 sq. inches (1996.54 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocit (m /sec 10 011 0.25 1.04 631 0.02 0.25 0.32 20 039 0.89 2.07 1262 0.09 0.89 0.63 30 0.82 1.89 3.11 1893 0.18 1.89 0.95 40 1.39 3.22 4.15 2523 0.31 3.22 1.26 50 2.10 4.87 518 3154 0.48 4.87 1.58 60 2.95 6.82 6.22 3785 0.67 6.82 1.90 70 3.92 9.07 7.26 4416 0.89 9.07 2.21 80 5.02 11.61 8.29 5047 1.14 11.61 2.53 90 6.24 14.44 9.33 5678 1.41 14.44 2.84 100 7.59 17.55 10.37 6309 1.72 17.55 3.16 110 9.06 20.93 11.40 6940 2.05 20.93 3.48 120 10.64 24.58 12.44 7570 2.41 24.58 3.79 130 12.34 28.51 13.48 8201 2.79 28.51 4.11 140 14.15 32.70 14.51 8832 3.20 32.70 4.42 150 16.08 37.15 15.55 9463 3.64 37.15 4.74 160 18.13 41.86 16.59 10094 4.10 41.86 5.06 170 20.28 1 46.83 1 17.62 10725 4.59 46.83 5.37 180 22.54 52.05 18.66 11356 5.10 52.05 5.69 190 24.92 57.53 19.70 11986 5.64 57.53 6.00 200 27.40 63.25 20.73 12611 1 6.20 63.25 6.32 Hazen Williams Formula Maximum O.D. = 2.1270 inches (54.026 mm) Nominal O.D. = 2.1250 inches (53.975 mm) Minimum O.D. = 2.1230 inches (53.924 mm) Nominal I.D. = 2.0090 inches (51.0286 mm) Nominal Wall Thickness = 0.0580 inches (1.4732 mm) Flow Area = 3.1699 sq. inches (2045.11 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec) 10 0.10 0.23 1.01 631 0.02 0.23 0.31 20 0.36 0.84 2.02 1262 0.08 0.84 0.62 30 0.77 1.78 3.04 1893 0.17 1.78 0.93 40 1.31 3.04 4.05 2523 0.30 3.04 1.23 50 1.98 4.59 5.06 3154 0.45 4.59 1.54 60 2.78 6.43 6.07 3785 0.63 6.43 1.85 70 3.70 8.55 7.08 4416 0.84 8.55 2.16 80 4.74 10.95 8.10 5047 1.07 10.95 2.47 90 5.89 13.62 9.11 5678 1.33 13.62 2.78 100 7.16 16.55 10.12 6309 1.62 16.55 3.08 110 8.54 19.74 11.13 6940 1.93 19.74 3.39 120 10.03 23.19 12.15 7570 2.27 23.19 3.70 130 11.64 26.89 13.16 8201 2.63 26.89 4.01 140 13.35 30.84 14.17 8832 3.02 30.84 4.32 150 15.17 35.04 15.18 9463 3.43 35.04 4.63 160 17.10 39.48 16.19 10094 3.87 39.48 4.94 170 19.13 44.17 17.21 10725 4.33 44.17 5.24 180 21.26 49.09 18.22 11356 4.81 49.09 5.55 190 23.50 54.26 19.23 11986 5.32 54.26 5.86 200 25.84 59.66 20.24 12617 5.85 59.66 6.17 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. - ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Hazen Williams Formula Maximum O.D. = 2.6270 inches (66.7258 mm) Nominal O.D. = 2.6250 inches (66.675 mm) Minimum O.D. = 2.6230 inches (66.6242 mm) Nominal I.D. = 2.4350 inches (61.849 mm) Nominal Wall Thickness = 0.0950 inches (2.413 mm) Flow Area = 4.6568 sq. inches (3004.380 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Veloci (m ) sec. 20 0.14 0.33 1.38 1262 0.03 0.33 0.42 40 0.51 1.19 2.76 2523 0.12 1.19 0.84 60 1.09 2.52 4.13 3785 0.25 2.52 1.26 80 1.86 4.30 5.51 5047 0.42 4.30 1.68 100 2.81 6.49 6.89 6309 0.64 6.49 2.10 120 3.94 9.10 8.27 7570 0.89 9.10 2.52 140 5.24 12.10 9.65 8832 1.18 12.10 2.94 160 6.71 15.49 11.02 10094 1.52 15.49 3.36 180 8.34 19.26 12.40 11356 1.89 19.26 3.78 200 10.14 23.41 13.78 12617 2.29 23.41 4.20 220 12.10 27.92 15.16 13879 2.74 27.92 4.62 240 14.21 32.79 16.53 15141 3.21 32.79 5.04 260 16.48 38.03 17.91 16403 3.73 38.03 5.46 280 18.91 43.62 19.29 17664 4.28 43.62 5.88 300 21.48 49.55 20.67 18926 4.86 49.55 6.30 320 24.21 55.84 22.05 20188 5.48 55.84 6.72 COPPER 1 AND FRICTION LOSS II FEET Maximum O.D. = 2.6270 inches (66.7258 mm) Nominal O.D. = 2.6250 inches (66,675 mm) Minimum O.D. = 2.6230 inches (66.6242 mm) Nominal I.D. = 2.4650 inches (62.611 mm) Nominal Wall Thickness = 0.0800 inches (2.032 mm) Flow Area = 4.7723 sq. inches (3078.87 sq. mm) Hazen Williams formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/ 100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 20 0.13 0.31 1.34 1262 0.03 0.31 0.41 40 0.48 1.12 2.69 2523 0.11 1.12 0.82 60 1.03 2.38 4.03 3785 0.23 2.38 1.23 80 1.75 4.05 5.38 5047 0.40 4.05 1.64 100 2.65 6.12 6.72 6309 0.60 6.12 2.05 120 3.71 8.57 8.07 7570 0.84 8.57 2.46 140 4.93 11.40 9.41 8832 1.12 11.40 2.87 160 6.32 14.59 10.76 10094 1.43 14.59 3.28 180 7.86 18.15 12.10 11356 1.78 18.15 3.69 200 9.55 22.05 13.45 12617 2.16 22.05 4.10 220 11.40 26.30 14.79 13879 2.58 26.30 4.51 240 13.39 30.90 16.13 15141 3.03 30.90 4.92 260 15.53 35.83 17.48 16403 3.51 35.83 5.33 280 17.81 41.09 18.82 17664 4.03 41.09 534 300 20.24 46.69 2017 . 18926 4.58 46.69 6.15 320 22.81 52.61 21.51 20188 5.16 52.61 6.56 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS ' 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 COPPER WATER AND f t FEET Maximum O.D. = 2.6270 inches (66.7258 mm) Nominal O.D. = 2.6250 inches (66.675 mm) Minimum O.D. = 2.6230 inches (66.6242 mm) Nominal I.D. = 2.4950 inches (63.373 mm) Nominal Wall Thickness = 0.0650 inches (1.651 mm) Flow Area = 4.8891 sq. inches (3154.27 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 20 0.13 0.29 1.31 1262 0.03 0.29 0.40 40 0.46 1.06 2.62 2523 0.10 1.06 0.80 60 0.97 2.24 3.94 3785 0.22 2.24 1.20 80 1.65 3.82 5.25 5047 0.37 3.82 1.60 100 2.50 5.77 6.56 6309 0.56 5.77 2.00 120 3.50 8.08 7.87 7570 0.79 8.08 2.40 140 4.65 10.75 9.19 8832 1.05 10.75 2.80 160 5.96 13.76 10.50 10094 1.35 13.76 3.20 180 7.41 17.11 11.81 11356 1.68 17.11 3.60 200 9.01 20.79 13.12 12617 2.04 20.79 4.00 220 10.75 24.80 14.44 13879 2.43 24.80 4.40 240 12.62 29.13 15.75 15141 2.86 29.13 4.80 260 14.64 33.78 17.06 16403 3.31 33.78 5.20 280 16.80 38.75 18.37 17664 3.80 38.75 5.60 300 19.09 44.02 19.69 18926 4.32 44.02 6.00 320 21.51 49.60 21.00 20188 4.87 49.60 6.40 Hazen Williams Formula Maximum O.D. = 3.1270 inches (19.4258 mm) Nominal O.D. = 3.1250 inches (79.375 mm) Minimum O.D. = 3.1230 inches (79.3242 mm) Nominal I.D. = 2.9070 inches (73.8378 mm) Nominal Wall Thickness = 0.1090 inches (2.7686 mm) Flow Area = 6.6371 sq. inches (4282.01 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 25 0.09 0.21 1.21 1577 0.02 0.21 0.37 50 0.33 0.76 2.42 3154 0.07 0.76 0.74 75 0.70 1.61 3.63 4732 0.16 1.61 1.11 100 1.19 2.74 4.83 6309 0.27 2.74 1.47 125 1.79 4.14 6.04 7886 0.41 4.14 1.84 150 2.51 5.80 7.25 9463 0.57 5.80 2.21 175 3.34 7.72 8.46 11040 0.76 7.72 2.58 200 4.28 9.88 9.67 12617 0.97 9.88 2.95 225 5.33 12.29 10.88 14195 120 1229 3.32 250 6.47 14.94 12.08 15772 1.46 14.94 3.68 275 7.72 17.82 13.29 17349 1.75 17.82 4.05 300 9.07 20.93 14.50 18926 2.05 20.93 4.42 325 10.52 24.27 15.71 20503 2.38 24.27 4.79 350 12.07 27.83 16.92 22080 2.73 27.83 5.16 375 13.72 31.62 1813 23658 3.10 31.62 5.53 400 15.46 35.63 1 19.34 25235 3.50 35.63 5.89 425 17.29 39.86 1 20.54 26812 3.91 39.86 1 6.26 U.S. customary units in this document are the standard; the metric units are provided for reference only The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0221 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455 F7/ O.. TUBE WATER ii FEET Maximum O.D. = 3.1270 inches (79.4258 mm) Nominal O.D. = 3.1250 inches (79.375 mm) Minimum O.D. = 3.1230 inches (79.3242 mm) Nominal I.D. = 2.9450 inches (74.803 mm) Nominal Wall Thickness = 0.0900 inches (2.286 mm) Flow Area = 6.8118 sq. inches (4394.69 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ful00 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m/sec .) 25 0.09 0.20 1.18 1577 0.02 020 0.36 50 0.31 0.71 2.35 3154 0.07 031 0.72 75 0.65 1.51 3.53 4732 0.15 1.51 1.08 100 1.11 2.57 4.71 6309 0.25 2.57 1.44 125 1.68 3.89 5.89 7886 0.38 3.89 1.79 150 2.36 5.45 7.06 9463 0.53 5.45 2.15 175 3.14 7.25 8.24 11040 0.71 7.25 2.51 200 4.02 9.28 9.42 12617 0.91 9.28 2.87 225 5.00 11.54 10.60 14195 1.13 11.54 3.23 250 6.08 14.02 11.77 15772 1.37 14.02 3.59 275 7.25 16.72 12.95 17349 1.64 16.72 3.95 300 8.52 19.65 14.13 18926 1.93 19.65 4.31 325 9.88 22.78 1531 20503 2.23 22.78 4.67 350 11.33 26.13 16.48 22080 2.56 26.13 5.02 375 12.88 29.69 17.66 23658 2.91 29.69 5.38 400 14.51 33.45 18.84 25235 3.28 33.45 5.74 425 1 16.24 1 37.42 1 20.02 1 26812 1 3.67 1 37.42 1 6.10 Hazen Williams Formula Maximum O.D. = 3.1270 inches Q9.4258 mm) Nominal O.D. = 3.1250 inches (79.375 mm) Minimum O.D. = 3.1230 inches Q9.3242 mm) Nominal I.D. = 2.9810 inches (75.7174 mm) Nominal Wall Thickness = 0.0720 inches (1.8288 mm) Flow Area = 6.9793 sq, inches (4502.79 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 25 0.08 0.19 1.15 1577 0.02 0.19 0.35 50 0.29 0.67 2.30 3154 0.07 0.67 0.70 75 0.62 1.42 3.45 4732 0.14 1.42 1.05 100 1.05 2.43 4.60 6309 0.24 2.43 1.40 125 1.59 3.67 5.75 7886 0.36 3.67 1.75 150 2.22 5.14 6.90 9463 0.50 5.14 2.10 175 2.96 6.83 8.04 11040 0.67 6.83 2.45 200 3.79 8.75 9.19 12617 0.86 8.75 2.80 225 4.71 10.88 1034 14195 1.07 10.88 3.15 250 5.73 13.22 11.49 15772 1.30 13.22 3.50 275 6.83 15.76 12.64 17349 1.55 15.76 3.85 300 8.03 18.52 13.79 18926 1.82 18.52 4.20 325 9.31 21.47 14.94 20503 2.11 21.47 4.55 350 10.68 24.63 16.09 22080 2.42 24.63 4.90 375 12.14 27.98 17.24 23658 2.75 27.98 5.25 400 13.68 31.53 18.39 25235 3.09 31.53 5.60 425 1 1530 1 35.27 1 19.54 1 26812 1 3.46 1 35.27 1 5.95 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST- • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 W ATER AND FRICTION LOSS PER 100 FEET Maximum O.D. = 3.6270 inches (92.1258 mm) Nominal O.D. = 3.6250 inches (92.075 mm) Minimum O.D. = 3.6230 inches (92.0242 mm) Nominal I.D. = 3.3850 inches (85.979 mm) Nominal Wall Thickness = 0.1200 inches (3.048 mm) Flow Area = 6.9993 sq. inches (5805.97 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (tt/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 25 0.04 010 0.89 1577 0.01 0.10 0.27 50 0.16 036 1.78 3154 0.04 0.36 0.54 75 0.33 0.77 2.67 4732 0.08 0.77 0.81 100 0.57 1.31 3.57 6309 0.13 1.31 1.09 125 0.85 1.98 4.46 7886 0.19 1.98 1.36 150 1.20 2.77 5.35 9463 0.27 2.77 1.63 175 1.59 3.68 6.24 11040 0.36 3.68 1.90 200 2.04 4.71 7.13 12617 0.46 4.71 2.17 225 2.54 5.86 8.02 14195 0.57 5.86 2.44 250 3.09 7.12 8.91 15772 0.70 7.12 2.72 275 3.68 8.49 9.80 17349 0.83 8.49 2.99 300 4.33 9.98 10.70 18926 0.98 9.98 3.26 325 5.02 11.57 11.59 20503 1.13 11.57 3.53 350 5.76 1127 12.48 22080 1.30 13.27 3.80 375 6.54 15A8 13.37 23658 1.48 15.08 4.07 400 7.37 16.99 14.26 25235 1.67 16.99 4.35 425 8.25 19.01 15.15 26812 1.87 19.01 4.62 450 9.17 21.12 16.04 28389 2.07 21.12 4.89 475 10.13 23.35 16.93 29966 2.29 23.35 5.16 500 11.14 25.67 17.83 31543 2.52 25.67 5.43 525 12.20 28.10 18.72 33121 2.76 28.10 5.70 550 13.29 30.62 19.61 34698 3.01 30.62 5.98 575 1 14.43 33.25 1 20.50 36275 1 3.26 1 33.25 6.25 600 1 15.62 1 35.97 1 21.39 37852 1 3.53 1 35.91 1 6.52 Hazen Williams Formula Maximum O.D. = 3,6270 inches (92.1258 mm) Nominal O.D. = 3,6250 inches (92.075 mm) Minimum O.D. = 3.6230 inches (92.0242 mm) Nominal I.D. = 3.4250 inches (86.995 mm) Nominal Wall Thickness = 0.1000 inches (2.540 mm) Flow Area = 9.2132 sq. inches (5944.00 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m/sec .) 25 0.04 0.09 0.87 1577 0.01 0.09 0.27 50 0.15 0.34 1.74 3154 0.03 0.34 0.53 75 0.31 0.73 2.61 4732 0.07 0.73 0.80 100 0.53 1.23 3.48 6309 0.12 1.23 1.06 125 0.81 1.87 4.35 7886 0.18 1.87 1.33 150 1.13 2.61 5.22 9463 0.26 2.61 1.59 175 1.51 3.48 6.09 11040 0.34 3.48 1.86 200 1.93 4.45 6.96 12617 0.44 4.45 2.12 225 2.40 5.53 7.84 14195 0.54 5.53 239 250 2.91 633 8.71 15772 0.66 6.73 2.65 275 3.48 8,02 9.58 17349 0.79 8.02 2.92 300 4.09 9.42 10.45 18926 0.92 9.42 3.18 325 4.74 10.93 11.32 20503 107 10.93 3.45 350 5.44 12.53 12.19 22080 1.23 12.53 3.71 375 6.18 1424 13.06 23658 1.40 14.24 3.98 400 6.96 16.05 13.93 25235 1.57 16.05 4.25 425 7.79 17.95 14.80 26812 1.76 17.95 4.51 450 8.66 19.95 15.67 28389 1.96 19.95 4.78 475 9.57 22.05 16.54 29966 2.16 22.05 5.04 500 10.52 24.25 1 17.41 31543 2.38 24.25 5.31 525 11.52 26.54 18.28 33121 2.61 26.54 5.57 550 12.55 28.92 19.15 34698 2.84 28.92 5.84 575 13.63 31.40 20.02 36275 3.08 31.40 6.10 600 14.75 33.97 20.89 37852 3.34 33.97 6.37 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 O.. WATER ii FEET Maximum O.D. = 3.6270 inches (92.1258 mm) Nominal O.D. = 3.6250 inches (92.075 mm) Minimum O.D. = 3.6230 inches (92.0242 mm) Nominal I.D. = 3.4590 inches (87.8586 mm) Nominal Wall Thickness = 0.0830 inches (2.1082 mm) Flow Area = 9.397 sq. inches (6062.59 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 25 0.04 0.09 0.85 1577 0.01 0.09 0.26 50 0.14 0.33 1.71 3154 0.03 0.33 0.52 75 0.30 0.69 2.56 4732 0.07 0.69 038 100 0.51 1.18 3.41 6309 0.12 1.18 1.04 125 0.77 1.78 4.27 7886 0.17 1.78 1.30 150 1.08 2.49 5.12 9463 0.24 2.49 1.56 175 1.44 3.31 5.97 11040 0.32 3.31 1.82 200 1.84 4.24 6.83 12617 0.42 4.24 2.08 225 2.29 527 7.68 14195 0.52 5.27 2.34 250 2.78 6.41 8.54 15772 0.63 6.41 2.60 275 3.31 7.65 9.39 17349 0.75 7.65 2.86 300 3.89 8.98 10.24 18926 0.88 8.98 3.12 325 4.52 10.41 11.10 20503 1.02 10.41 3.38 350 5.18 11.94 11.95 22080 1.17 11.94 3.64 375 5.89 13.57 12.80 23658 1.33 13.57 3.90 400 6.63 1529 13.66 25235 1.50 15.29 4.16 425 7.42 17.11 14.51 26812 1.68 17.11 4.42 450 8.25 19.02 15.36 28389 1.87 19.02 4.68 475 9.12 21.02 16.22 29966 2.06 21.02 4.94 500 10.03 23.11 17.07 31543 2.27 23.11 5.20 525 10.98 25.29 17.92 33121 2.48 25.29 5.46 550 11.96 27.56 18.78 34698 2.71 27.56 5.72 575 12.99 29.93 19.63 36275 2.94 29.93 5.98 600 1 14.06 1 32.38 20.49 1 37852 1 3.18 32.38 6.24 Hazen Williams Formula Maximum O.D. = 4.1270 inches (104.8258 mm) Nominal O.D. = 4.1250 inches (104.775 mm) Minimum O.D. = 4.1230 inches (104.7242 mm) Nominal I.D. = 3.8570 inches (97.9678 mm) Nominal Wall Thickness = 0.1340 inches (3.4036 mm) Flow Area = 11.6839 sq. inches 0538.01 sq, mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 50 0.08 0.19 1.37 3154 0.02 0.19 0.42 100 0.30 0.69 2.75 6309 0.07 0.69 0.84 150 0.63 1.47 4.12 9463 0.14 1.47 1.26 200 1.08 2.50 5.49 12617 0.24 2.50 1.67 250 1.64 3.77 6.86 15772 0.37 3.77 2.09 300 2.29 5.29 8.24 18926 0.52 5.29 2.51 350 3.05 7.03 9.61 22080 0.69 7.03 2.93 400 3.91 9.00 10.98 25235 0.88 9.00 3.35 450 4.86 11.19 12.36 28389 1.10 11.19 3.77 500 5.90 1160 13.73 31543 1.34 13.60 4.18 550 7.04 16.23 15.10 34698 1.59 1623 4.60 600 8.27 19.06 16.48 37852 1.87 19.06 5.02 650 9.60 22.10 17.85 41006 2.17 22.10 5.44 700 11.01 25.35 19.22 44161 2.49 25.35 5.86 750 12.51 28.80 20.59 47315 2.83 28.80 6.28 800 14.10 32.45 21.97 50469 3.19 32.45 6.70 850 15.77 36.30 23.34 53624 3.57 36.30 7.11 900 1 17.53 1 40.35 24.71 56778 3.97 40.35 7.53 950 19.38 44.60 26.09 59932 4.38 44.60 7.95 1000 2131 49.04 1 27.46 63087 1 4.82 4904 8.37 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST- • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Hazen Williams Formula FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/ 100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 50 0.08 0.18 1.34 3154 0.02 0.18 0.41 100 028 0.65 2.68 6309 0.06 0.65 0.82 150 0.60 1.38 4.02 9463 0.14 1.38 1.22 200 1.02 2.35 536 12617 0.23 2.35 1.63 250 1.54 3.55 630 15772 0.35 155 2.04 300 2.16 4.98 8.04 18926 0.49 4.98 2.45 350 2.87 6.62 9.38 22080 0.65 6.62 2.86 400 3.68 8.48 10.72 25235 0.83 8.48 3.27 450 4.57 10.54 12.05 28389 1.03 10.54 3.67 500 5.56 12.81 13.39 31543 1.26 12.81 4.08 550 6.63 1528 14.73 34698 1.50 15.28 4.49 600 7.79 17.95 16.07 37852 1.76 17.95 4.90 650 9.04 20.81 17.41 41006 2.04 20.81 5.31 700 10.37 2187 18.75 44161 2.34 23.87 5.72 750 11.78 2712 20.09 47315 2.66 27.12 6.12 800 13.27 30.56 21.43 50469 3.00 30.56 6.53 850 14.85 1 34.18 1 22.77 53624 3.36 1 34.18 1 6.94 900 16.51 38.00 24.11 56778 3.73 38.00 7.35 950 18.25 41.99 25.45 59932 4.13 41.99 7.76 1000 20.07 46.17 26.79 63087 4.54 46.17 8.17 Hazen Williams Formula Maximum O.D. = 4.1270 inches (104.8258 mm) Nominal O.D = 4.1250 inches (104.775 mm) Minimum O.D. = 4.1230 inches (104.7242 mm) Nominal I.D. = 3.9050 inches (99.187 mm) Nominal Wall Thickness = 0.1100 inches (2.794 mm) Flow Area = 11.9766 sq. inches (7726.80 sq. mm) C Factor = 150 Maximum O.D. = 4.1270 inches (104.8258 mm) Nominal O.D. = 4.1250 inches (104.775 mm) Minimum O.D. = 4.1230 inches (104.7242 mm) Nominal I.D. = 3.9350 inches (99.949 mm) Nominal Wall Thickness = 0.0950 inches (2.413 mm) Flow Area = 12.1613 sq, inches (1845.87 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m ) sec.) 50 0.08 0.17 1.32 3154 0.02 0.17 0.40 100 0.27 0.63 2.64 6309 0.06 0.63 0.80 150 0.58 1.33 3.96 9463 0.13 1.33 1.21 200 0.98 2.27 5.28 12617 0.22 2.27 1.61 250 1.48 3.42 6.60 15772 0.34 3.42 2.01 300 2.08 4.80 7.91 18926 0.47 4.80 2.41 350 2.77 6.38 9.23 22080 0.63 6.38 2.81 400 3.54 817 10.55 25235 0.80 8.17 3.22 450 4.41 10.15 11.87 28389 1.00 10.15 3.62 500 536 12.34 13.19 31543 1.21 12.34 4.02 550 6.39 14.72 14.51 34698 1.45 14.72 4.42 600 7.51 17.29 15.83 37852 1.70 17.29 4.82 650 8.71 20.05 17.15 41006 1.97 20.05 5.23 700 9.99 23.00 18.47 44161 2.26 23.00 5.63 750 11.35 26.13 19.79 47315 2.57 26.13 6.03 800 12.79 29.44 2111 50469 2.89 29.44 6.43 850 14.31 1 32.93 1 22.42 53624 3.24 32.93 6.83 900 15.91 36.61 23.74 56778 3.60 36.61 7.24 950 17.58 40.46 25.06 59932 3.98 40.46 7.64 1000 19.33 44.49 26.38 63087 431 44.49 8.04 U.S. customary units in this document are the standard; the metric units are provided for reference only The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 COPPER WATER FLOW AND FRICTION LOSS PER 100 FEET Maximum O.D. = 5.1270 inches (130.2258 mm) Nominal O.D. = 5.1250 inches (130.175 mm) Minimum O.D. = 5.1230 inches (130.1242 mm) Nominal I.D. = 4.8050 inches (122.047 mm) Nominal Wall Thickness = 0.1600 inches (4.064 mm) Flow Area = 18.1333 sq. inches (11698.87 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (rt/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (M/s 50 0.03 0.07 0.88 3154 0.01 0.07 0.27 100 0.10 0.24 1.77 6309 0.02 0.24 0.54 150 0.22 0.50 2.65 9463 0.05 0.50 0.81 200 0.37 0.86 3.54 12617 0.08 0.86 1.08 250 0.56 1.30 4.42 15772 0.13 1.30 1.35 300 0.79 1.81 5.31 18926 0.18 1.81 1.62 350 1.05 2.41 6.19 22080 0.24 2.41 1.89 400 1.34 3.09 7.08 25235 0.30 3.09 2.16 450 1.67 3.84 7.96 28389 0.38 3.84 2.43 500 2.03 4.67 8.85 31543 0.46 4.67 2.70 550 2.42 5.57 9.73 34698 0.55 5.57 2.9 600 2.84 6.54 10.62 37852 0.64 6.54 3.24 650 3.29 7.59 11.50 41006 0.75 7.59 3.51 700 3.78 8.70 12.39 44161 0.85 8.70 3.77 750 4.29 9.89 13.27 47315 0.97 9.89 4.04 800 4.84 11.14 14.15 50469 1.09 11.14 4.31 850 5.41 12.46 15.04 53624 1.22 12.46 4.58 900 6.02 13.85 15.92 56778 1.36 13.85 4.85 950 6.65 15.31 16.81 59932 1.50 15.31 5.12 1000 7.32 16.83 17.69 63087 1.65 16.83 5.39 1050 8.01 18.42 18.58 66241 1.81 18.42 5.66 1100 8.73 20.08 19.46 69395 1.97 20.08 5.93 1150 1 9.48 1 21.80 20.35 1 72550 1 2.14 21.80 1 6.20 Hazen Williams Formula Maximum O.D. = 5.1270 inches (130.2258 mm) Nominal O.D. = 5.1250 inches (130.175 mm) Minimum O.D. = 5.1230 inches (130.1242 mm) Nominal I.D. = 4.8750 inches (123.825 mm) Nominal Wall Thickness = 0.1250 inches (3.175 mm) Flow Area = 18.6655 sq. inches (12042.22 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 50 0.03 0.06 0.86 3154 0.01 0.06 0.26 100 0.10 0.22 1.72 6309 0.02 0.22 0.52 150 0.20 0.47 2.58 9463 0.05 0.47 0.79 200 0.35 0.80 3.44 12617 0.08 0.80 1.05 250 0.52 1.21 4.30 15772 0.12 1.21 1.31 300 0.73 1.69 5.16 18926 0.17 1.69 1.57 350 0.98 2.25 6.02 22080 0.22 2.25 1.83 400 1.25 2.88 6.88 25235 0.28 2.88 2.10 450 1.55 3.58 7.73 28389 0.35 3.58 2.36 500 1.89 4.35 8.59 31543 0.43 4.35 2.62 550 2.25 5.19 9.45 34698 0.51 5.19 2.88 600 2.65 6.10 10.31 37852 0.60 6.10 3.14 650 3.07 7.07 11.17 41006 0.69 7.07 3.41 700 3.52 8.11 12.03 44161 0.80 8.11 3.67 750 4.00 9.21 12.89 47315 0.91 9.21 3.93 800 4.51 10.38 13.75 50469 1.02 10.38 4.19 850 5.05 11.61 14.61 53624 1.14 11.61 4.45 900 5.61 12.91 15.47 56778 1.27 12.91 4.72 950 6.20 14.27 16.33 59932 1.40 14.27 4.98 1000 6.82 15.69 17.19 63087 1.54 15.69 524 1050 7.46 17.17 18.05 66241 1.69 17.17 5.50 1100 8.13 18.71 18.91 69395 1.84 18.71 5.76 1150 8.83 20.32 19.77 72550 1 2.00 1 20.32 1 6.02 U.S. customary units in this document are the standard; the metric units are provided for reference only The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 O.. AND ii FEET Maximum O.D. = 5.1270 inches (130.2258 mm) Nominal O.D. = 5.1250 inches (130.175 mm) Minimum O.D. = 5.1230 inches (130.1242 mm) Nominal I.D. = 4.9070 inches (124.6378 mm) Nominal Wall Thickness = 0.1090 inches (2.1686 mm) Flow Area = 18.9113 sq. inches (12200.83 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m/sec. 50 0.03 0.06 0.85 3154 0.01 0.06 0.26 100 0.09 0.21 1.70 6309 0.02 0.21 0.52 150 0.20 0.45 2.54 9463 0.04 0.45 0.78 200 0.34 0.77 3.39 12617 0.08 0.77 1.03 250 0.51 1.17 4.24 15772 0.11 1.17 1.29 300 0.71 1.64 5.09 18926 0.16 1.64 1.55 350 0.95 2.18 5.94 22080 0.21 2.18 1.81 400 1.21 2.79 1 6.79 25235 0.27 2.79 2.07 450 1.51 3.47 7.63 28389 0.34 3.47 2.33 500 1.83 4.22 8.48 31543 0.41 4.22 2.59 550 2.18 5.03 9.33 34698 0.49 5.03 2.84 600 2.56 5.91 10.18 37852 0.58 5.91 3.10 650 2.97 6.85 11.03 41006 0.67 6.85 3.36 700 3.41 7.86 11.88 44161 0.77 7.86 3.62 750 3.88 8.93 1232 47315 0.88 8.93 3.88 800 4.37 10.06 1157 50469 0.99 10.06 4.14 850 4.89 11.25 14.42 53624 1.11 11.25 4.40 900 5.43 12.51 15.27 56778 1.23 12.51 4.65 950 6.01 13.82 16.12 59932 1.36 13.82 4.91 1000 6.60 15.20 16.97 63087 1.49 15.20 5.17 1050 7.23 16.63 1 17.81 66241 1.64 16.63 5.43 1100 7.88 18.13 18.66 69395 1.78 18.13 5.69 1150 1 8.56 19.68 1 19.51 72550 1.94 19.68 5.95 Hazen Williams Formula Maximum O.D. = 6.1270 inches (155.6258 mm) Nominal O.D. = 6.1250 inches (155.575 mm) Minimum O.D. = 6.1230 inches (155.5242 mm) Nominal I.D. = 5.7410 inches (145.8214 mm) Nominal Wall Thickness = 0.1920 inches (4.8768 mm) Flow Area = 25.8860 sq. inches (16700.61 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 100 0.04 0.10 124 6309 0.01 0.10 0.38 200 0.16 0.36 2.48 12617 0.04 0.36 0.76 300 0.33 036 3.72 18926 0.07 0.76 1.13 400 0.56 1.30 4.96 25235 0.13 1.30 1.51 500 0.85 1.96 6.20 31543 0.19 1.96 1.89 600 1.19 235 7.44 37852 0.27 2.75 2.27 700 1.59 3.66 8.68 44161 0.36 3.66 2.64 800 2.04 4.69 9.92 50469 0.46 4.69 3.02 900 2.53 5.83 11.15 56778 0.57 5.83 3.40 1000 3.08 7.08 12.39 63087 0.70 7.08 3.78 1100 3.67 8.45 13.63 69395 0.83 8.45 4.16 1200 4.31 9.92 14.87 75704 0.98 9.92 4.53 1300 5.00 11.50 16.11 82013 1.13 11.50 4.91 1400 5.74 13.19 17.35 88321 1.30 13.19 5.29 1500 6.52 14.99 18.59 94630 1.47 14.99 5.67 1600 7.35 16.89 19.83 100939 1.66 16.89 6.04 1700 1 8.22 18.90 1 21.07 107247 1 1.86 1 18.90 6.42 1800 1 9.14 1 21.00 1 22.31 1 113556 1 2.07 1 21.00 1 6.80 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST ^ . ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 ' COPPER " 1 AND FRICTION LOSS 11 FEET Maximum O.D. = 6.1270 inches (155.6258 mm) Nominal O.D. = 6.1250 inches (155.575 mm) Minimum O.D. = 6.1230 inches (155.5242 mm) Nominal I.D. = 5.8450 inches (148.463 mm) Nominal Wall Thickness = 0.1400 inches (3.556 mm) Flow Area = 26.8324 sq. inches (17311.17 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 100 0.04 0.09 1.20 6309 0.01 0.09 0.36 200 014 0.33 2.39 12617 0.03 0.33 0. 300 0.30 0.70 3.59 18926 0.07 0.70 1.0 400 0.52 1.19 4.78 25235 0.12 1.19 1.46 500 0.78 1.80 5.98 31543 0.18 1,80 1.82 600 1.09 2.52 7.17 37852 025 2.52 2.19 700 1.46 3.35 8.37 44161 0.33 3.35 2. 800 1.87 4.29 9.57 50469 0.42 4.29 2. 900 2.32 5.34 10.76 56778 0.52 5.34 3.28 1000 2.82 6.49 11.96 63087 0.64 6.49 3.6 1100 3.36 7.74 13.15 69395 0.76 7.74 4.01 1200 3.95 9.09 14.35 75704 0.89 9.09 4.37 1300 4.58 10.54 15.54 82013 1.04 10.54 4.74 1400 5.26 12.09 16.74 88321 1.19 12.09 5.10 1500 5.98 13.74 17.94 94630 1.35 13.74 5.47 1600 6.73 15.48 19.13 100939 1.52 15.48 5.83 1700 1 7.53 1 17.32 20.33 107247 1 1.70 17.32 1 6.20 1800 1 8.38 1 19.25 1 21.52 113556 1 1.89 1 19.25 1 6.56 Hazen Williams Formula Maximum O.D. = 6.1270 inches (155.6258 mm) Nominal O.D. = 6.1250 inches (155.575 mm) Minimum O.D. = 6.1230 inches (155.5242 mm) Nominal I.D. = 5.8810 inches (149.3774 mm) Nominal Wall Thickness = 0.1220 inches (3.0988 mm) Flow Area = 27.1639 sq. inches (17525.07 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocit (m /sec 100 0.04 0.09 1.18 6309 0.01 0.09 0.36 200 0.14 0.32 2.36 12617 0.03 0.32 0.72 300 0.29 0.68 3.54 18926 0.07 0.68 1.08 400 0.50 1.16 4.72 25235 0.11 1.16 1.44 500 0.76 1.75 5.91 31543 0.17 1.75 1.80 600 1,06 2.45 7.09 37852 0.24 2.45 2.16 700 1.41 3.26 8.27 44161 0.32 3.26 2.52 800 1.81 417 9.45 50469 0.41 4.17 2.88 900 2.25 518 10.63 56778 0.51 5.18 3.24 1000 2.74 6.30 11.81 63087 0.62 6.30 3.60 1100 3.27 7.51 12.99 69395 0.74 7.51 3.96 1200 3.84 8.82 14.17 75704 0.87 8.82 4.32 1300 4.45 10.23 15.35 82013 1.01 10.23 4.68 1400 5.10 11.74 16.54 88321 1.15 11.74 5.04 1500 5.80 13.33 1732 94630 1.31 13.33 5.40 1600 6.54 15.02 18.90 100939 1.48 15.02 5.76 1700 7.31 16.81 20.08 107247 1.65 16.81 6.12 1800 1 813 18.68 1 21.26 1 113556 1 1.84 1 18.68 1 6,48 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Hazen Williams Formula Maximum O.D. = 8.1270 inches (206.4258 mm) Nominal O.D. = 8.1240 inches (206.3496 mm) Minimum O.D. = 8.1210 inches (206.2734 mm) Nominal I.D. = 7.5820 inches (192.5828 mm) Nominal Wall Thickness = 0.2710 inches (6.8834 mm) Flow Area = 45.1500 sq, inches (29128.95 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (Psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m/100 m) Velocity (m /sec 200 0.04 0.09 1.42 12617 0.01 0.09 0.43 400 0.15 0.34 2.84 25235 0.03 0.34 0.87 600 0.31 0.71 4.26 37852 0.07 0.71 1.30 800 0.53 1.21 5.68 50469 0.12 1.21 1.73 1000 0.80 1.83 7.11 63087 0.18 1.83 2.17 1200 1.11 2.56 8.53 75704 0.25 2.56 2.60 1400 1.48 3.41 9.95 88321 0.34 3.41 3.03 16W 1.90 4.36 11.37 100939 0.43 4.36 3.47 1800 2.36 5.43 12.79 113556 0.53 5.43 3.90 2000 2.87 6.60 14.21 126173 0.65 6.60 4.33 2200 3.42 7.87 15.63 138791 0.77 7.87 4.76 2400 4.02 9.24 17.05 151408 0.91 9.24 5.20 2600 4.67 10.72 18.48 164025 1.06 10.72 5.63 2800 5.35 12.29 19.90 176643 1.21 12.29 6.06 3000 6.08 13.96 21.32 189260 1.38 13.96 6.50 3200 6.85 15.73 22.74 201877 1.55 15.73 6.93 3400 7.67 17.60 1 24.16 1 214495 1 1.73 17.60 1 7.36 3600 8.53 19.57 25.58 227112 1.93 19.57 7.80 3800 9.42 21.62 27.00 239729 2.13 21.62 8.23 4000 10.36 1 23.78 28.42 252347 2.34 1 23.78 8.66 Maximum O.D. = 8.1270 inches (206.4258 mm) Nominal O.D. = 8.1240 inches (206.3496 mm) Minimum O.D. = 8.1210 inches (206.2734 mm) Nominal I.D. = 7.7240 inches (196.1896 mm) Nominal Wall Thickness = 0.2000 inches (5.080 mm) Flow Area = 46.8570 sq. inches (30230.26 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (Psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /se 200 0.04 0.09 1.37 12617 0.01 0.09 0.42 400 0.13 0.31 2.74 25235 0.03 0.31 0.83 600 0.28 0.65 4.11 37852 0.06 0.65 1.25 800 0.48 1.11 5.48 50469 0.11 1.11 1.67 1000 0.73 1.67 6.85 63087 0.16 1.67 2.09 1200 1.02 2.34 8.22 75704 0.23 2.34 2.50 1400 1.35 3.12 9.59 88321 0.31 3.12 2.92 1600 1.73 3.99 10.96 100939 0.39 3.99 3.34 1800 2.16 4.96 12.32 113556 0.49 4.96 3.76 2000 2.62 6.03 13.69 126173 0.59 6.03 4.17 2200 3.13 7.19 15.06 138791 0.71 7.19 4.59 2400 3.68 8.44 16.43 151408 0.83 8.44 5.01 2600 4.26 9.79 17.80 164025 0.96 9.79 5.43 2800 4.89 11.23 19.17 176643 1.11 11.23 5.84 3000 5.56 12.76 20.54 189260 1.26 12.76 6.26 3200 6.26 14.38 21.91 201877 1.42 14.38 6.68 3400 7.01 16.08 23.28 214495 1.58 16.08 7.10 3600 7.79 17.88 24.65 227112 1.76 17.88 7.51 3800 8.61 19.76 26.02 239729 1.95 19.76 7.93 4000 9.47 21.72 27.39 252347 2.14 21.72 8.35 Hazen Williams Formula U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Hazen Williams Formula Maximum O.D = 8.1270 inches (206.4258 mm) Nominal O.D. = 8.1240 inches (206.3496 mm) Minimum O.D. = 8.1210 inches (206.2734 mm) Nominal I.D. = 7.7840 inches (197.7136 mm) Nominal Wall Thickness = 0.1700 inches (4.3180 mm) Flow Area = 47.5878 sq. inches (30701.74 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocit (m /sec 200 0.04 0.08 1.35 12617 0.01 0.08 0.41 400 0.13 0.30 2.70 25235 0.03 0.30 0.82 600 0.27 0.63 4.05 37852 0.06 0.63 1.23 800 0.46 1.07 5.39 50469 0.10 1.07 1.64 1000 0.70 1.61 6.74 63087 0.16 1.61 2.05 1200 0.98 2.26 8.09 75704 0.22 2.26 2.47 1400 1.30 3.00 9.44 88321 0.30 3.00 2.88 1600 1.67 3.84 10.79 100939 0.38 3.84 129 1800 2.08 4.78 12.14 113556 0.47 4.78 3.70 2000 2.53 5.80 13.48 126173 0.57 5.80 4.11 2200 3.01 6.92 14.83 138791 0.68 6.92 4.52 2400 3.54 8.13 16.18 151408 0.80 8.13 4.93 2600 4.11 9.43 17.53 164025 0.93 9.43 5.34 2800 4.71 10.81 18.88 176643 1.07 10.81 5.75 3000 5.35 12.29 20.23 189260 1.21 12.29 6.16 3200 6.03 13.85 21.57 201877 1.36 13.85 6.58 3400 6.75 15.49 22.92 214495 1.53 15.49 6.99 3600 1 7.50 17.22 24.27 227112 1.70 1722 7.40 3800 8.29 1 19.03 1 25.62 239729 1 1.88 1 19.03 1 7.81 4000 912 1 20.92 1 26.97 252347 1 2.06 1 20.92 1 8.22 Hazen Williams Formula Maximum O.D. = 10.1270 inches (257.2258 mm) Nominal O.D. = 10.1230 inches (257.1242 mm) Minimum O.D. = 10.1190 inches (257.0226 mm) Nominal I.D. = 9.4470 inches (239.9538 mm) Nominal Wall Thickness = 0.3380 inches (8,5852 mm) Flow Area = 70.0935 sq. inches (45221.52 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocit (m /sec. 200 0.01 0.03 0.92 12617 0.00 0.03 0.28 400 0.05 0.12 183 25235 0.01 0.12 0.56 600 0.11 0.24 2.75 37852 0.02 0.24 0.84 800 0.18 0.42 3.66 50469 0.04 0.42 1.12 1000 0.27 0.63 4.58 63087 0.06 0.63 1.40 1200 0.38 0.88 5.49 75704 0.09 0.88 1.67 1400 0.51 1.17 6.41 88321 0.12 1.17 1.95 1600 0.65 1.50 7.32 100939 0.15 1.50 2.23 1800 0.81 1.86 8.24 113556 0.18 1.86 2.51 2000 0.98 2.26 9.15 126173 0.22 2.26 2.79 2200 1.17 2.70 10.07 138791 0.27 2.70 3.07 2400 1.38 3.17 10.99 151408 0.31 3.17 3.35 2600 1.60 3.68 11.90 164025 0.36 3.68 3.63 2800 1.84 4.22 12.82 176643 0.42 4.22 3.91 3000 2.09 4.79 13.73 189260 0.47 4.79 4.19 3200 2.35 5.40 14.65 201877 0.53 5.40 4.46 3400 2.63 6.04 15.56 214495 0.60 6.04 4.74 3600 2.92 6.71 16.48 227112 0.66 6.71 5.02 3800 3.23 7.42 17.39 239729 0.73 7.42 5.30 4000 3.55 8.16 18.31 252347 0.80 8.16 5.58 4200 3.89 8.93 19.22 264964 0.88 8.93 5.86 4400 4.24 9.73 20.14 277581 0.96 1 9.73 6.14 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST- • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 COPPER W ATER AND FRICTION LOSS PER 100 FEET Maximum O.D. = 10.1270 inches (257.2258 mm) Nominal O.D. = 10.1230 inches (257.1242 mm) Minimum O.D. = 10.1190 inches (257.0226 mm) Nominal I.D. = 9.6230 inches (244.4242 mm) Nominal Wall Thickness = 0.2500 inches (6.3500 mm) Flow Area = 72.7295 sq. inches (46922.19 sq. mm) Hazen Williams formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m/100 m) Velocity (m /sec 200 0.01 0.03 0.88 12617.33 0.00 0.03 0.27 400 0.05 0.11 1.76 25234.67 0.01 0.11 0.54 600 0.10 0.22 2.65 37852.00 0.02 0.22 0.81 800 0.16 0.38 3.53 50469.33 0.04 0.38 1.08 1000 0.25 0.57 4.41 63086.67 0.06 0.57 1.34 1200 0.35 0.80 5.29 75704.00 0.08 0.80 1.61 1400 0.46 1.07 6.18 88321.33 0.11 1.07 1.88 1600 0.60 1.37 7.06 100938.67 0.13 1.37 2.15 1800 0.74 1.70 7.94 113556.00 0.17 1.70 2.42 2000 0.90 2.07 8.82 126173.33 0.20 2.07 2.69 2200 1.07 2.47 9.70 138790.67 0.24 2.47 2.96 2400 1.26 2.90 10.59 151408.00 0.29 2.90 3.23 2600 1.46 3.36 11.47 164025.33 0.33 3.36 3.50 2800 1.68 3.85 12.35 176642.67 0.38 3.85 3.76 3000 1.91 4.38 13.23 189260.00 0.43 4.38 4.03 3200 2.15 4.93 14.12 201877.33 0.49 4.93 4.30 3400 2.40 5.52 15.00 214494.67 0.54 5.52 4.57 3600 2.67 6.13 15.88 227112.00 0.60 6.13 4.84 3800 2.95 6.78 16.76 239729.33 0.67 6.78 5.11 4000 3.25 7.45 17.65 252346.67 0.73 7.45 5.38 4200 3.56 8.16 18.53 264964.00 0.80 8.16 5.65 4400 1 3.88 1 8.89 19.41 277581.33 0.88 1 8.89 1 5.92 Hazen Williams Formula Maximum O.D. = 10.1270 inches (257.2258 mm) Nominal O.D. = 10.1230 inches (257.1242 mm) Minimum O.D. = 10.1190 inches (257.0226 mm) Nominal I.D. = 9.6990 inches (247.3546 mm) Nominal Wall Thickness = 0.2120 inches (5.3848 mm) Flow Area = 73.8829 sq. inches (47666.28 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss Ali 00 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Veloci (m )sec 200 0.01 0.03 0.87 12617 0.00 0.03 0.26 400 0.04 0.10 1.74 25235 0.01 0.10 0.53 600 0.09 0.21 2.61 37852 0.02 0.21 0.79 800 0.16 0.37 3.47 50469 0.04 0.37 1.06 1000 0.24 0.55 4.34 63087 0.05 0.55 1.32 1200 0.34 0.77 5.21 75704 0.08 0.77 1.59 1400 0.45 1.03 6.08 88321 0.10 1.03 1.85 1600 0.57 1.32 6.95 100939 0.13 1.32 2.12 1800 0.71 1.64 7.82 113556 0.16 1.64 2.38 2000 0.87 1.99 8.68 126173 0.20 1.99 2.65 2200 1.03 2.37 9.55 138791 0.23 2.37 2.91 2400 1.21 2.79 10.42 151408 0.27 2.79 3.18 2600 1.41 3.23 11.29 164025 0.32 3.23 3.44 2800 1.62 3.71 12.16 176643 0.37 3.71 3.71 3000 1.84 4.21 13.03 189260 0.42 4.21 3.97 3200 2.07 4.75 13.90 201877 0.47 4.75 4.24 3400 2.31 5.31 14.76 214495 0.52 5.31 4.50 3600 2.57 5.90 15.63 227112 0.58 5.90 4.76 3800 2.84 6.53 16.50 239729 1 0.64 6.53 5.03 4000 3,13 7.17 17.37 252347 1 0.71 7.17 5.29 4200 3.42 7.85 18.24 264964 1 0.77 7.85 5.56 4400 1 3.73 1 8.56 19.11 277581 1 0.84 1 8.56 5.82 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 F7 COPPER WATER AND FRICTION LOSS PER 100 FEET Maximum O.D. = 12.1270 inches (308.0258 mm) Nominal O.D. = 12.1230 inches (307.9242 mm) Minimum O.D. = 12.1190 inches (307.8226 mm) Nominal I.D. = 11.3130 inches (287.3502 mm) Nominal Wall Thickness = 0.4050 inches (10.2870 mm) Flow Area = 100.5184 sq. inches (64850.43 sq. mm) Hazen Williams Formula C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 1000 0.11 0.26 3.19 63087 0.03 0.26 0.97 1200 0.16 0.37 3.83 75704 0.04 0.37 1.17 1400 0.21 0.49 4.47 88321 0.05 0.49 1.36 1600 0.27 0.62 5.11 100939 0.06 0.62 1.56 1800 0.34 0.77 5.75 113556 0.08 0.77 1.75 2000 0.41 0.94 6.38 126173 0.09 0.94 1.95 2200 0.49 1.12 7.02 138791 0.11 1.12 2.14 2400 0.57 1.32 7.66 151408 0.13 1.32 2.33 2600 0.67 1.53 8.30 164025 0.15 1.53 2.53 2800 0.76 1.75 8.94 176643 0.17 1.75 2.72 3000 0.87 1.99 9.58 189260 0.20 1.99 2.92 3200 0.98 2.25 10.21 201877 0.22 2.25 3.11 3400 1.09 2.51 10.85 214495 0.25 2.51 3.31 3600 1.22 2.79 11.49 227112 0.28 2.79 3.50 3800 1.34 3.09 12.13 239729 0.30 3.09 3.70 4000 1.48 3.39 12.77 252347 0.33 3.39 3.89 4200 1.62 3.71 13.41 264964 037 3.71 4.09 4400 1.76 4.05 14.04 277581 0.40 4.05 428 4600 192 4.39 14.68 290199 0.43 4.39 4.48 4800 2.07 4.75 15.32 302816 0.47 4.75 4.67 5000 214 5.13 15.96 315433 0.51 5.13 4.86 5200 2.40 5.51 16.60 328051 0.54 5.51 5.06 5400 2.58 5.91 17.24 340668 0.58 5.91 5.25 5600 2.76 6.32 1 17.87 1 353285 1 0.62 1 6.32 1 5.45 5800 2.94 6.75 18.51 365903 0.67 6.75 5.64 6000 3.13 7.18 19.15 378520 0.71 1 7.18 5.84 6200 3.33 7.63 19.79 391137 0.75 1 7.63 6.03 Hazen Williams Formula Maximum O.D. = 12.1270 inches (308.0258 mm) Nominal O.D. = 12.1230 inches (307.9242 mm) Minimum O.D. = 12.1190 inches (307.8226 mm) Nominal I.D. = 11.5630 inches (293.7002 mm) Nominal Wall Thickness = 0.2800 inches (7.1120 mm) Flow Area = 105.0101 sq. inches (67748.29 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (1kPa /100 m) Head Loss (m /100 m) Velocity (m /sec.) 1000 0.10 0.23 3.06 63087 0.02 0.23 0.93 1200 0.14 0.33 3.67 75704 0.03 0.33 1.12 1400 0.19 0.44 4.28 88321 0.04 0.44 1.30 1600 0.24 0.56 4.89 100939 0.06 0.56 1.49 1800 0.30 0.70 5.50 113556 0.07 0.70 1.68 2000 0.37 0.85 6.11 126173 0.08 0.85 186 2200 0.44 1.01 6.72 138791 0.10 1.01 2.05 2400 0.52 1.19 7.33 151408 0.12 1.19 2.23 2600 0.60 1.37 7.94 164025 0.14 1.37 2.42 2800 0.69 1.58 8.55 176643 016 1.58 2.61 3000 0.78 1.79 9.17 189260 0.18 1.79 2.79 3200 0.88 2.02 9.78 201877 0.20 2.02 2.98 3400 0.98 2.26 10.39 214495 0.22 2.26 3.17 3600 1.09 2.51 11.00 227112 0.25 2.51 3.35 3800 1.21 2.77 11.61 239729 0.27 2.77 3.54 4000 1.33 3.05 12.22 252347 0.30 3.05 3.72 4200 1.46 3.34 12.83 264964 0.33 3.34 3.91 4400 1.59 3.64 13.44 277581 0.36 3.64 4.10 4600 1.72 3.95 14.05 290199 0.39 3.95 4.28 4800 1.86 4.27 14.67 302816 0.42 4.27 4.47 5000 2.01 4.61 15.28 315433 0.45 4.61 4.66 5200 2.16 4.96 15.89 328051 0.49 4.96 4.84 5400 2.32 5.31 16.50 340668 0.52 5.31 5.03 5600 2.48 5.68 1 17.11 353285 0.56 5.68 5.21 5800 2.65 6.07 17.72 365903 0.60 6.07 5.40 6000 1 2.82 6.46 18.33 378520 0.64 6.46 5.59 6200 1 2.99 6.86 18.94 391137 0.68 6.86 5.77 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Hazen Williams Formula Maximum O.D. = 12.1270 inches (308.0258 mm) Nominal O.D. = 12.1230 inches (307.9242 mm) Minimum O.D. = 12.1190 inches (307.8226 mm) Nominal I.D. = 11.6150 inches (295.021 mm) Nominal Wall Thickness = 0.2540 inches (6.4516 mm) Flow Area = 105.9567 sq. inches (68359.01 sq. mm) C Factor = 150 FLOW, Q (GPM) Pressure Loss (psi /100 ft) Head Loss (ft/100 ft) Velocity (ft. /sec.) FLOW, Q (cu. cm /sec.) Pressure Loss (kPa /100 m) Head Loss (m/100 m) Velocity 1000 0.10 0.23 3.03 63087 0.02 0.23 0.92 1200 0.14 0.32 3.63 75704 0.03 0.32 1.11 1400 0.19 0.43 4.24 88321 0.04 0.43 1.29 1600 0.24 0.55 4.84 100939 0.05 0.55 1.48 1800 0.30 0.68 5.45 113556 0.07 0.68 1.66 2000 0.36 0.83 6.06 126173 0.08 0.83 1.85 2200 0.43 0.99 6.66 138791 0.10 0.99 2.03 2400 0.51 1.16 7.27 151408 0.11 1.16 2.22 2600 0.59 1.35 7.87 164025 0.13 1.35 2.40 2800 0.67 1.54 8.48 176643 0.15 1.54 2.58 3000 0.76 1.75 9.08 189260 0.17 1.75 2.77 3200 0.86 1.98 9.69 201877 0.19 1.98 2.95 3400 0.96 2.21 10.30 214495 0.22 2.21 3.14 3600 1.07 2.46 10.90 227112 0.24 2.46 3.32 3800 1.18 2.71 11.51 239729 0.27 2.71 3.51 4000 1.30 2.98 12.11 252347 0.29 2.98 3.69 4200 1.42 3.27 12.72 264964 0.32 3.27 3.88 4400 1.55 3.56 13.32 277581 0.35 3.56 4.06 4600 1.68 3.87 13.93 290199 0.38 3.87 4.25 4800 1.82 4.18 14.53 302816 0.41 4.18 4.43 5000 1.97 4.51 15.14 315433 0.44 4.51 4.61 5200 2.11 4.85 15.75 328051 0.48 4.85 4.80 5400 2.27 5.20 16.35 340668 0.51 5.20 4.98 5600 2.43 5.56 16.96 353285 0.55 5.56 5.17 5800 1 2.59 1 5.93 17.56 365903 0.59 1 5.93 5.35 6000 2.76 6.32 18.17 378520 0.62 6.32 5.54 6200 2.93 6.71 1 18.77 391137 1 0.66 6.71 1 5.72 U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Copper Water Tubecontinued COPPER Tube Type STANDARDS, Color Code Standard , LENGTHS Application Commercially Available Lengths Nominal or Standard Sizes Drawn Annealed Type K Green ASTM B 88 Domestic Water Service Distribution Fire Protection Solar Fuel /Fuel Oil HVAC Snow Melting Straight Lengths: 1 /4 -inch to 8 -inch 10 -inch 12 -inch 20 ft. (6.1m) 20 ft. (6.1m) 18 ft. (5.5m) 18 ft. (5.5m) 12 ft. (3.7m) 12 ft. (3.7m) Coils: '/4 -inch to 1 -inch 1 1 /4 -inch & 1 2 -inch — 60 ft. (18.3m) — 100 ft. (30.5m) — 60 ft. (18.3m) — 40 ft. (12.2m) — 4 5 ft. (13.7m) Type L Blue ASTM B 88 Domestic Water Service Distribution Fire Protection Solar Fuel /Fuel Oil Natural Gas Liquified Petroleum (LP) Gas HVAC Snow Melting Straight Lengths: '/4 -inch to 10 -inch 12 -inch 20 ft. (6.1m) 20 ft. (6.1m) 18 ft. (5.5m) 18 ft. (5.5m) Coils: 1 /4 -inch to 1 -inch 1 1 /4 -inch & 1' /2 -inch 2 -inch — 60 ft. (18.3m) — 100 ft. (30.5m) — 60 ft. (18.3m) — 40 ft. (12.2m) — 45 ft. (13.7m) Type M Red ASTM B 88 Domestic Water Service Distribution Fire Protection Solar Fuel /Fuel Oil HVAC Snow Melting Straight Lengths: '/4 -inch to 12 -inch 20 ft. (6.1 m) N/A DWV Yellow ASTM B 306 Drain Waste Vent HVAC Solar Straight Lengths: 1'/4 -inch to 8 -inch 20 ft. (6.1 m) N/A ACR Blue ASTM B 280 Air Conditioning Refrigeration Natural Gas Liquified Petroleum (LP) Gas Straight Lengths: '/4 -inch to 4 1 /8 -inch 20 ft. (6.1 m) 20 ft. (6.1 m)' Coils: 1 /e -inch to 1 /e -inch — 50 ft. (15.3m)' OXY MED OXY /MED OXY /ACR ACR/MED Type K Green Type L Blue ASTM B 819 Medical Gas Straight Lengths: 1 /4 -inch to 8 -inch 20 ft. (6.1 m) N/A Type G Yellow ASTM B 837 Natural Gas Liquified Petroleum (LP) Gas Straight Lengths: 3/0- inch to 1'/e -inch 12 ft. (3.7m) 12 ft. (3.7m)' 20 ft. (6.1 m) 20 ft. (6.1 m) Coils: 3/8- inch to' /e - inch — 60 ft. (18.3m)' — 100 ft. (30.5m)' 'Available as special order only. U.S. customary units in this document are the standard; the metric units are provided for reference only. The values stated in each system are not exact equivalents. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 The Fine Art of Soldering When adjoining surfaces of copper and copper alloys meet under proper conditions of cleanliness and temperature, solder will make a perfect adhesion. The strength of joint is equal to or even greater than the strength of tube alone. Surface tension seals the joint. Capillary attraction draws solder into, around, and all about the joint. It's easy to learn to make a perfect solder joint when you use NIBCO Fittings. 1. Cut tube end square, ream, burr and size. o � Apply solder flux to outside of tube and inside of cup of fitting carefully so that surfaces to be joined are completely covered. Use flux sparingly. Remove flame and feed solder into the joint at one or two points until a ring of solder appears at the end of the fitting. The correct amount of solder is approximately equal to 1 the diameter of the fitting... 3 /4" (20mm) solder for '12" fitting, etc. Use sand cloth or steel wire brush to clean tube and cup to a bright metal finish. NO n*o 4. Apply flame to the fitting to heat tube and solder cup of fitting until solder melts when placed at joint of tube and fitting. 6. Remove excess solder with a small brush or wiping cloth while the solder is plastic. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 35 The Fine Art of Brazing Best results will be obtained by a skilled operator employing the step -by -step brazing technique that follows: The tube should be cut to desired length with a square cut, preferably in a square -end sawing vise. The cutting wheel of the type specifically designed for cutting copper tube will also do a satisfactory job. The tube should be the exact length needed, so that the tube will enter the cup of the fitting all the way to the shoulder of the cup. Remove all slivers and burrs left from cutting the tube, by reaming and filing, both inside and outside. 2. To make a proper brazing joint, the clearance between the solder cup and the tube should be approximately 0.001" to 0.010" (0.0254mm to 0.254mm). Maintaining a good fit on parts to be brazed insures: Ease of Application — Excessively wide tolerances tend to break capillary force; and, as a result the alloy will either fail to flow throughout the joint or may flush out of the joint. Corrosion Resistance — There is also a direct relation between the corrosion resistance of a joint and the clearance between members. Economy — If brazing alloys are to be used economically, they, of necessity, must be applied in the joint proper and in minimum quantities, using merely enough alloy to fill the area between the members. 0 The surfaces to bejoined must be clean and free from oil, grease and heavy oxides. The end of the tube need be cleaned only for a distance slightly more than it is to enter the cup. Special f wire brushes r designed to clean tube ends may be used, but they should be carefully used so that an excessive amount of metal will not be removed from the tube. Fine sand cloth or emery cloth may also be used with the same precautions. The cleaning should not be done with steel wool, because of the likelihood of leaving small slivers of the steel or oil in the joint. The cup of the fitting should be cleaned by methods similar to those used for the tube end, and care should be observed in removing residues of the cleaning medium. Attempting to braze a contaminated or an improperly cleaned surface will result in an unsatisfactoryjoint. Brazing alloys will not flow over or bond to oxides; and oily or greasy surfaces tend to repel fluxes, leaving bare spots which will oxidize, resulting in voids and inclusions. 5. Flux should be applied to the tube and solder cup sparingly and in a fairly thin consistency. Avoid flux on areas not cleaned. Particularly avoid getting excess flux into the inside of the tube itself. Flux has three principal functions to perform: A. It prevents the oxidation of the metal surfaces during the heating operation by excluding oxygen. B. It absorbs and dissolves residual oxides that are on the surface and those oxides which may form during the heating operation. C. It assists in the flow of the alloy by presenting a clean nascent surface for the melted alloy to flow over. In addition, it is an excellent temperature indicator, especially if an indicating flux is used. 6. Immediately after fluxing, the parts to be brazed should be assembled. If fluxed parts are allowed to stand, the water in the flux will evaporate, and dried flux is liable to flake off, exposing the metal surfaces to oxidation from the heat. Assemble the joint by inserting the tube into the cup, hard against the stop. The assembly should be firmly supported so that it will remain in alignment during the brazing operation. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST- • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 7. Brazing is started by applying heat to the parts to be joined. The preferred method is by the oxyacetylene flame. Propane and other gases are sometimes used on smaller sizes. A slightly reducing flame should be used, with a slight feather on the inner blue cone; the outer portion of the flame, pale green. Heat the tube first, beginning at about one inch from the edge of the fitting. Sweep the flames around the tube in short strokes up and down at right angles to the run of the tube. It is very important that the flame be in continuous motion and should not be allowed to remain on any one point to avoid burning through the tube. Generally, the flux may be used as a guide as to how long to heat the tube, continuing heating after the flux starts to bubble or work, and until the flux becomes quiet and transparent, like clear water. The flux will pass through four stages: A. At 212 °F (100 °C) the water boils off. B. At 600 °F (315.6 °C) the flux becomes white and slightly puffy and starts to work. C. At 800 °F (426.7 °C) it lays against the surface and has a milky appearance. D. At 1100 °F (593.3 °C) it is completely clear and active and has the appearance of water. Now switch the flame to the fit base of the cup. Heat uniformly sweeping the flame from the fitting to the tube until the flux the fitting becomes quiet. Avoid excessive heating of cast fittings. When the flux appears liquid and transparent on both the tube and the fitting, start sweeping the flame back and forth along the axis of the joint to maintain heat on the parts to be joined, especially toward the base of the cup of the fitting. The flame must be kept moving to avoid burning the tube or the fitting. 10. Apply the brazing wire or rod at a point where the tube enters the sock+ -C."- fitting. The temperature of the j should be hot enough to melt tf brazing alloy. Keep the flame a1 from the rod or wire as it is fed into the joint. Keep both the fitting and the tube heated by moving the flame back and forth from one to the other as the alloy is drawn into the joint. When the proper temperature is reached, the alloy will flow readily into the space between the tube outer wall and the fitting socket, drawn in by the natural force of capillary attraction. When the joint is filled, a continuous fillet of brazing alloy will be visible completely around the joint. Stop feeding as soon as the joint is filled, using table on page 54 as a guide for the alloy consumption. NOTE: For tubing one inch and larger, it is difficult to bring the whole joint up to heat at one time. It frequently will be found desirable to use a double -tip torch to maintain the proper temperature over the larger area. A mild pre- heating of the whole fitting is recommended. The heating then can proceed as in steps 7, 8, 9, and 10. If difficulty is encountered in getting the whole joint up to heat at one time, then when the joint is nearly up to the desired temperature the alloy is concentrated in a limited area. At the brazing temperature the alloy is fed into the joint and the torch is then moved to an adjacent area and the operation carried on progressively all around the joint. HORIZONTAL JOINTS — When making horizontal joints, it is preferable to start applying the brazing alloy at the 5 o'clock position, then move around to the 7 o'clock position and then move up the sides to the top of the joint, making sure that the operations overlap. VERTICAL JOINTS — On vertical joints, it is immaterial where the start Is mane. IT the opening or the cup is pointed down, care should be taken to avoid overheating the tube, as this may cause the alloy to run down the tube. If this condition is encountered, take the heat away and allow the alloy to set. Then reheat the solder cup of the fitting to draw up the alloy. After the brazing alloy has set, remove residual flux from the joint area as it is corrosive and presents an unclean appearance and condition. Hot water or steam and a soft cloth should be used. Wrot fittings may be chilled; however it is advisable to allow cast fittings to cool naturally to some extent before applying a swab. All flux must be removed before inspection and pressure testing. TROUBLE SPOTS If the alloy fails to flow or has a tendency to ball up, it indicates oxidation on the metal surfaces, or insufficient heat on the parts to be joined. If work starts to oxidize during heating, it indicates too little flux, or a flux of too thin consistency. If the brazing alloy refuses to enter the joint and tends to flow over the outside of either member of the joint, it indicates this member is overheated, or the other is underheated, or both. In both cases, operations should be stopped and the joints disassembled, recleaned and fluxed. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Po I eth y lene I I (PE lubing FITTING SYSTEM — INSERT /CRIMP TYPE* Making a Connection 1. Using a tube cutter, cut tubing squarely and remove burrs. 3. Insert ribbed fitting into tubing until tubing contacts the fitting shoulder (tube stop). Position the crimp ring on the tubing so that the edge of the ring is 1/8" to 1/4" (3 to 6mm) from the end of the tube. 4. Center the crimping tool jaws exactly over the ring while maintaining its position relative to the fitting. Crimp the ring by closing the handles together to the positive stop on the tool. Check the after - crimped diameter of each ring with the crimp gauge. If the small flats on the gauge do not fit over the crimped ring, the ring is under - crimped. Cut out any under - crimped rings and fittings and completely replace. DO NOT RE- CRIMP. *NIBCO recommends the use of copper crimp rings ONLY and a properly calibrated full circle crimping tool for joining PEX tubing and copper barbed fittings. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 Polybutylene Tubing Making a Connection Using a tube cutter, cut tubing squarely and remove burrs. 3. Insert fitting into tubing, then position crimp ring squarely over barbs. Proper alignment is important for making the best connection. TOOLS AND RINGS • Use tools recommended by fitting and tubing manufacturers. All tools must make a full - circle crimp. • Check tool adjustment at least daily, and readjust as necessary. • Use crimp rings of copper as recommended by NIBCO INC. 2. Slide copper crimp ring on tubing. Only copper crimp rings should be used to ensure the highest quality connection. 4. Center the crimping tool jaws exactly over the ring, and bring the tool handles together until totally closed to the stop indicator. Check each crimp ring with the caliper gauge after completion. If the small flats on the gauge do not fit over the crimped ring, the ring is undercrimped. Cut out any undercrimped rings and fittings, and completely replace. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455 n J_ Frequently Asked Questions Q: What is the pressure rating of a given fitting? Q: Can dissimilar metals (i.e., copper and iron) be joined together A: Fittings are rated per Table 1 of ASME 616.22. The system rated without use of dielectric insulators to prevent corrosion? pressure shall be the lowest of the fitting, tube or joint. A: In most situations dissimilar metals (copper /iron /steel) can be joined successfully without using dielectric insulators. Factors to consider: Q: When copper fails in a system, what is the problem? 1. The composition of the two metals. A: MOST COMMON: 2. The rate of liquid flow past the two metals. 1. Velocity — fluid is moving too fast. Recommendation: 2 -3 fps (0.0508 - 0.0762 m /s) hot water 140 °F, 5 -8 fps (0.127- 0.2032 m /s) cold water. Refer to pages 68 -93. 2. Turbulence — burrs left on the cut tubing causes a tumbling effect causing localized erosion and eventual failure. 3. Aggressive Waters — tend to cause pitting or green staining of fixtures. Aggressive, hard well waters that cause pitting typically are found to have total dissolved solids including suflates and chlorides, a pH in the range of 7.2 to 7.8, a high content of carbon dioxide gas and the pressence of dissolved oxygen gas. Soft acidic waters that cause green staining typically tend to be more corrosive. Low alkalinity, low mineralization, pH levels of 7 or lower should be avoided. LESS COMMON: 1. Flux Corrosion —using too much flux when making joints can potentially leave residue and cause isolated corrosion. Flux should be used sparingly and system adequately flushed. 2. Electrolysis — stray (D.C.) current; inadequate grounding for the piping. 3. Sand or other solid particulates — erosion /corrosion problems can occur. Lower velocities must be maintained if solids are present in flow media. 4, Galvanic Corrosion — destruction of a material by electrochemical interaction between the environment and the material. Q: Copper tubing wall thickness is designated "K," "L" or "M." What are the copper fittings applicable to? A: Copper fittings' wall thickness is determined by standards (ASME B -16:22 and MSS -SP -104). These standards address minimum wall thickness (per size) for the full range of copper fittings and are not intended to match tubing wall thicknesses. 3. Chemicals in the water which could enhance or destroy protective films. 4. The relative areas of the two metals - unless the surface area of the less noble (steel) material is less that 5% of the more noble (copper) material, the need for a dielectric separator is not needed. (Failures due to galvanic corrosion are very unusual and only occur under very strict conditions.) 5. Local code requirements. Q: What should the installer of copper unions know and do in order to assure a proper leak -free installation? A. The following should be done: 1. Make sure the ground joint(mating area of unionis tail and thread pieces) are free of nicks and scratches. 2. Spray the ground joint area with a food grade silicone spray or apply bees wax to enhance seating. 3. Make sure alignment of line does not put lateral stress on the ground joint seal. 4. Make sure that excess solder (droplets) do not reach the ground joint area. ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY SL • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 °°�,� Residential G 50-YEAR Cop Plumbin V \ LU1IIEUN'ARRANTY Limited Warrant What the warranty terms mean In this warranty "Manufacturer" refers to the company listed below which manufactured the Product and any person or company that assumes its obligations under this warranty. "Homeowner" means you as the owner of the residential building in the United States in which the Product has been installed and also means any succeeding owner during the original warranty term. "Product" means the copper water tube and /or copper or brass fittings manufactured by the Manufacturer for the residential building market in the United States. Each Manufacturer listed below separately and individually warrants only Products it has manufactured and does not warrant Products of any other company, whether or not listed below. Date the warranty begins The warranty begins on the date of the new home purchase, or in the case of home additions or renovations, on the date the installation is completed. The warranty is transferable to succeeding Homeowners for the remainder of the original warranty term, in which case the date the warranty begins shall continue without change. What is covered The Manufacturer warrants to the Homeowner for a period of 50 years from the date the warranty begins that its properly installed Product will be free of failure as a result of defects in material or workmanship in manufacturing the Product. What the manufacturer wiI I do for you As long as (1) such a failure occurs within 50 years from the date the warranty begins and (2) the Homeowner promptly notifies the Manufacturer of the Product of that failure by contacting it through its 800 phone number listed below, the Manufacturer will correct that failure by repairing or replacing the Product within a reasonable time, without charge. This warranty is limited to the cost of repairing or replacing the Product, including installation. NIBCO TECHNICAL SERVICE 1- 888 - 446 -4226 Products What is not covered: Disclaimer of liability for consequential and other damages The Manufacturer does NOT warrant against failure: 1. of any product, parts, or systems that it has not manufactured; 2. if the Product is used for purposes other than residential plumbing applications; 3. caused by, contributed in whole or in part by, or resulting from, any of the following: (a) improper installation; (b) abuse, such as, without limitation, vandalism; (c) natural disasters, such as, without limitation, flooding, windstorm and lightning; (d) attachments or modifications to the Product that the Manufacturer did not authorize; (e) external causes, where external, physical or chemical qualities produce damage to the Product, such as, without limitation, aggressive water or an unsuitable or hostile environment; or (f) any other cause beyond the Manufacturer's control. The Manufacturer shall NOT be liable under any circumstances for any other direct or any indirect, incidental or consequential damages of any kind. This is the only warranty This warranty is the only warranty for the Product provided by the Manufacturer, and is and shall be in lieu of any and all other warranties, express or implied, including but not limited to an implied warranty of merchantability, and of all other obligations or liabilities on the part of the Manufacturer. None of the Manufacturer's employees, and no other person or business, is authorized to make any other warranty on the Manufacturer's behalf covering the product. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.514.295.3221 • FAX: +1.514.295.3455 711 F Numerical Index Figure Number Paae 100 Series Cast Heavy Flared 101 ............................... 23 104 ............................... 23 500 Series Cast Flared 500 .............................. 24 503 .............................. 23 504 .............................. 23 507 .............................. 23 507 -3 ........................... 23 507 -4 ........................... 23 511 ............................... 24 600 Series Wrot Pressure 600 . ............................... 9 600 - 2 ...........................15 736 .............................11 600 -DS ........................10 739 . .............................16 600 -RS .........................9 741 .. .............................15 601 . .............................10 748 ............................. 603 . ............................... 6 603- 2 ............................. 6 604 . ............................... 7 604 -2 .. . .......................... 7 606 . .............................11 764 . .............................15 606 - 2 ...........................11 771 . .............................16 607 . .............................12 775 . .............................16 607 -2 ...........................13 805 .............................. 607 -2 -2 ........................13 805 -N .......................... 607- 2- 2- LT ....................13 806 .............................. 607 -2- 1 .........................13 806- 2 ........................... 607 -2 -LT .......................13 807 .............................. 607 - 1 ............................12 807 -2 ........................... 607 -LT ..........................12 807 -3 ........................... 611 ......................... 17 -19 611 - 2 ............................19 36 616 . .............................16 36 617 . ............................... 9 618 . ............................... 8 618- 3 ............................. 8 619 ............................... 8 620 -L ............................ 8 621 .............................. 21 623 . .............................16 38 624 . .............................16 38 633 -W ......................... 21 638 . .............................16 33 698 .............................. 20 Figure Number Page 700 Series Cast Pressure 701 . .............................10 701- D ...........................10 702 .............................10 703 . ............................... 6 703- 2 ............................. 6 703 -5 ............................ 6 703 -513 .......................... 6 704 . ............................... 7 704- 2 ............................. 7 704 -2 -H ......................... 8 704 -F ............................. 7 704 -H ............................ 7 705 . .............................16 705- D ...........................17 706 - 2 ...........................12 707 . .............................12 707 -2 -4 ........................13 707 -3 ...........................14 707 -3 -5 ........................14 707 -3 -5 -A ....................14 707 -3 -6 ........................14 707 -4 ...........................14 707 -4 -6 ........................14 707 -5 ...........................14 707- 5- A ........................14 707 -6 ...........................15 708 . .............................15 710 -3 ...........................17 710 -3 -4 . .......................17 711 . .............................19 711 -5 ...........................19 711- A ...........................19 712 .............................. 20 712- 5 ........................... 20 713 ............................. 20 714 .............................. 20 717 . ............................... 9 717- D ............................. 9 718 -3 ............................. 8 724 -5 -A ......................10 733 .............................. 21 733- 2 ........................... 21 733- 3 ........................... 21 733- 4 ........................... 21 Figure Number Paae 735 . .............................11 34 736 .............................11 33 739 . .............................16 31 741 .. .............................15 32 748 ............................. 21 749 ............................. 21 750 . ............................... 8 750- 3 ............................. 8 750- 4 ............................. 8 764 . .............................15 32 771 . .............................16 33 775 . .............................16 33 800 Series Cast DWV 801 .............................. 34 801 -2 ........................... 33 801 -2 -7 ........................ 31 801- T ............................ 32 802 .............................. 32 802- C ........................... 32 802 -F ........................... 32 803 .............................. 32 803- 2 ........................... 32 804 .............................. 32 804- 2 ........................... 33 804 -T ........................... 33 805 .............................. 31 805 -N .......................... 31 806 .............................. 35 806- 2 ........................... 35 807 .............................. 35 807 -2 ........................... 35 807 -3 ........................... 36 807 -4 ........................... 36 807 -9 ........................... 36 808 .............................. 36 809 .............................. 36 810 .............................. 38 811 .............................. 37 811- 14 .......................... 37 811- 15 .......................... 37 812 .............................. 38 814 .............................. 38 816 .............................. 33 816- S ........................... 33 818 A.S.A .................... 36 834 .............................. 38 835 .............................. 37 835- B ........................... 37 836 .............................. 38 Figure Number Paae 837 .............................. 36 851 .............................. 34 851 -C ........................... 34 861 -LH ......................... 36 875- S ........................... 40 878 .............................. 40 879 .............................. 40 880 .............................. 39 881 .............................. 39 884 .............................. 39 885 .............................. 39 890 .............................. 39 891 .............................. 39 892 .............................. 39 892 -3 ........................... 39 892- A ........................... 39 900 Series Wrot DWV 901 .............................. 34 901 -2 ........................... 33 901 -2 -7 ........................ 31 901 -2 -F ........................ 33 901- 7 ............................ 31 901 -RP ......................... 34 903 .............................. 32 903- 2 ........................... 32 903 -7 ........................... 31 904 .............................. 33 904 -7 ........................... 31 905 .............................. 31 906 .............................. 35 906- 2 ........................... 35 907 .............................. 35 907 -2 ........................... 35 907 -LT .......................... 35 911 .............................. 37 917 -B ........................... 37 951 .............................. 34 960 .............................. 36 Copper Insert Fittings for Polybutylene PB198 .......................... 29 PB600 .......................... 29 PB600 -FA .................... 29 PB607 .......................... 29 PB607- FA ..................... 29 PB611 .......................... 29 Figure Number Paae Copper Insert Fittings for Polyethylene (PEX) PEX 198 .........................26 PEX600 .........................26 PEX600 .........................26 PEX600- 2 ......................26 PEX600 -FA ...................26 PEX600- T ......................26 PEX603 .........................26 PEX604 .........................26 PEX607 .........................26 PEX607 -FA ...................26 PEX611 .........................26 PEX707 -3 -5 ..................26 PEX841 .........................27 PEX100 .........................27 PEX616 ..........................27 m NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 NOTES NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455 NOTES ® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 globally t o n n e ct i n It's a new age of business, and a new way at NIBCO. From Elkhart, Indiana to Lodz, Poland, and points beyond, our company has integrated manufacturing, distribu- tion, and networked con tions to provide a seaml, of information and service, 24 hours a day, 7 days a week. But this integration hasn't hap- pened overnight. It's been part of a long -term strategic process that has pushed us to reconsid- er every aspect of our business. The result? We're a vertically integrated manufacturer with the products and systems in place to deliver low cost and high quality. NIBCO's products are manufactured under a Quality Management System conforming to the current revi- sion of ISO -9001 International Standards. We know the flow control industry is only going to get more demanding, and we are more than ready. We will continue to lead. That's what NIBCO is all about. World Headquarters NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227 TECH SERVICES PH:1.888.446A226 • FAX: 1.800.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com FITTINGS Wrot and cast copper pressure fittings • Wrot and cast copper drainage fittings • Wrot copper PEXlinke fittings • Cast copper alloy flared fittings • Cast copper alloy flanges • ABS and PVC DWV fittings • Schedule 40 PVC pressure fittings • CPVC CTS fittings • CPVC CTS- to-metal transition fittings • Schedule 80 PVC and CPVC systems • CPVC metric piping systems. VALVES & ACTUATION Pressure -rated bronze, iron and alloy -iron gate, globe and check valves • Pressure - rated bronze ball valves • Boiler specialty valves • Commercial and industrial butterfly valves • Circuit balancing valves • Carbon and stainless steel ball valves • ANSI flanged steel ball valves • Pneumatic and electric actuators and controls - Grooved ball and butterfly valves • High performance butterfly valves • UL /FM fire protection valves • MSS specification valves • Bronze specialty valves • Low - pressure gate, globe, check and ball valves • Frostproof sillcocks • Quarter -turn supply stops • PVC ball valves • CPVC CTS ball valves • Just Right recirculating valves. CHEMTROL® Thermoplastic pipe, valves and fittings in PVC, Corzan® CPVC, polypropylene and PVDF Kynar • Chem -Aire" thermoplastic compressed air piping systems • Pneumatic and electric actuation systems. Corzan' is a registered trademark of Nmeon. IP Holdings Corp Kynar' is a registered trademark of ATOFINA Chemicals, Inc TOLCOrm NIBCO' now offers complete support with its newest addition of TOLCO' brand piping solutions including: Pipe attachments • Structural attachments • Pipe rollers • Threaded products and accessories • Seismic components • Vibration isolation • Standard and specialty supports • TOL- Strut channel and components. . 011 A suite of services designed to make customers more efficient • More cost- effective • More informed • EDI— Electronic Data Interchange • VMI— Vendor Managed Inventory • NIBCO.com • NIBCOpartnercom • eNIBCO will continuously develop new products to deliver the competitive advantage. NIBC O AHEAD OF THE FLOW NIBCO INC. 1516 MI DDLEBURI STREET DOMESTIC CUSTOMER SERVICE TECHNICAL SERVICE WORLD HEADQUARTERS ELKHART, IN 465164740 PHONE 800 234 0227 PHONE. 888 446 4226 WEB www nibco. com USA FAX 800 234 0557 FAX 888 336 4226 INTERNATIONAL OFFICE PHONE «1/574 295 3221 FAX .1/574 295 3455 C- CF-0404 0 2004, NIBCO INC Printed in USA