FIRE SPRINKLER PERMIT
Commercial & Residential Fire Alarm shop drawings are required at the time of
application submittal and must include the following information:
1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min) stamp
2. Equipment cut sheets of materials
3. Hydraulic calculations
4. A State of Colorado contractor registration number
5. Plans must be submitted by a Registered Fire Protection Contractor
Project Street Address:
00 O
(Number) (Street) _ (Suite #)
Building /Complex Name: V,R �y r0`� c�✓1
Contractor Information:
Company: Sliw�es Ftv� 2aks' c
Company Address: _�Oa�. '5' -1 UL5bjJ
City: - C o ✓1Ak-Lt -- nt �� u � '' tt State: (_ Zip: O«
Contact Name: J(_�O t�t ��r GQe�1
Contact Phone: - 7 — L
E -Mail _fi a hart lean 6D- WILD - SA -
Town of Vail Contract istration No.:
Contractor Signature (required)
Property Information
Parcel #:
(For parcel #, contact Eagle County Assessors Office at 970 - 328 -8640 or
visit www.eaglecounty.us /patie)
Tenant Name:
Owner Name: B l c aL��` iQ +• ��d �c{�ia -{-rte
Complete Valuation for Fire Sprinkler Permit:
Fire Sprinkler $: 40.1 A
Office Use: (�
Project #:
Building Permit #: 1 t1 il"101) qS
Sprinkler Permit #:
Lot #: Block # Subdivision:
Detailed Description of Work: 1?e lp e -`' -�e_ J
reV&ft
(use additional sheet if necessary)
Detailed Location of Work:
Does a Monitored Fire Alarm Exist? Yes No( )
Does a Sprinkler System Exist? Yes No( )
Work Class:
New( ) Addition( ) Remodel' Repair( )
Retro -Fit ( ) Other( )
Type of Building:
Single - Family ( ) Duplex ( ) Multi - Family ( )
Commercial-474 Restaurant ( ) Other ( )
Date Received
JUL 0 s 2011
TOWN OF VAIL
01- Feb-10
Reim R
labi 2
A complete line of UL Listed and FM Approved
quick response extended coverage sprinklers
for light hazard applications.
Horizontal Sidewall Sprinklers are approved
for installation 4" to 12" (102mm - 305mm)
Model F1 FR56 QREC Sprinkler Types
Pendent
Horizontal Sidewall EC -8
Model F1 FR56 QREC Recessed Sprinkler Types
Recessed Extended Coverage Pendent F1 /F2 /FP
Recessed Extended coverage Horizontal Sidewall
Model F1 FR56 QREC Concealed
Extended Coverage Pendent
Approval Organizations
1. Listed by Underwriters Laboratories, Inc. and
Certified for Canada (cULus)
2. Factory Mutual Approvals (FM)
UL Listing Category
Sprinklers, Automatic & Open
Quick Response Extended Coverage Sprinkler (VNIV)
Product Description
Reliable Models F1FR56 QREC and F1FR56 QREC Re-
cessed Sprinklers are quick response sprinklers which
combine the durability for a standard sprinkler with the at-
tractive low profile of a decorative sprinkler.
The Models F1 FR56 QREC and F1 FR56 QREC Recessed
Automatic Sprinklers utilize a 3.Omm frangible glass bulb.
These sprinklers have demonstrated response times in
laboratory tests which are five times faster than standard
response sprinklers. This quick response enables these
sprinklers to apply water to a fire much faster than stan-
dard sprinklers of the same temperature rating.
Model F1 FR56 QREC Quick Response Extended Cover-
age Concealed Sprinkler is an attractive, low profile con-
cealed sprinkler assembly. This sprinkler assembly uti-
lizes a Model F1 FR56 QREC pendent sprinkler in a Model
CCP cup and push -on thread -off cover plate assembly.
The cup is securely factory threaded on the sprinkler's in-
let end. The assembly is shipped with a protective cap.
The sprinkler and cup are easily installed into the sprinkler
fitting using the Model RC1 Sprinkler Wrench. The cover
plate assembly is attached to the sprinkler cup using a
flexible tooth threaded engagement. The cover plate is
attached to the skirt using 135 °F (57 °C) ordinary tempera-
ture classification solder.
Bulletin 028 Rev. A
CD
W
c
Model F1 FR Series.
Quick Response co
Extended Coverage Spray
D
Extended Coverage
Pendent
Extended Coverage
Pendent Concealed
Extended Coverage
Horizontal Sidewall EC -8
When the ceiling temperature rises, the solder holding
the cover plate melts, allowing the release of this part and
thus exposing the Model F1 FR56 QREC sprinkler inside to
the rising ambient temperature.
The Temperature rating of the sprinkler identified by the
color of the glass bulb.
The glass bulb consists of an accurately controlled
amount of special fluid hermetically sealed inside a pre-
cisely manufactured glass capsule. This glass bulb is spe-
cially constructed to provide fast thermal response.
Application
Quick response sprinklers are used in fixed fire protection
systems: Wet, Dry, Deluge or Preaction. Care must be exer-
cised that the orifice size, temperature rating, deflector style
and sprinkler type are in accordance with the latest published
standards of the National Fire Protection Association or the ap-
proving authority having jurisdiction. Quick response sprinklers
are intended for installation as specified in NFPA 13.
The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Recessed Extended
Coverage Pendent F1/F2
Recessed Extended
Coverage Horizontal
Sidewall EC -8
Model F1 FR56 Quick Response Extended Coverage Pendent Sprinkle)
Deflector: EC
Installation Wrench: Model D Sprinkler Wrench
Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy
Installa ' D t
Nominal
Orifice
'12"
(15m n)
tlon
a a.
Pressure
Max. Area
Temperature
Sprinkler
Thread
"K" Factor
Sprinkler
Approval
Rating
Identification
Size
Length
Organizations
Numbers (SIN)
4.9 x 4.9
33
O F
oc
18 x 18
US
Metric
151.4
51.0 (3,5)
20 x 20
6.0 x 6.0
1 12" NPT
5.6
80
2.25"
(57mm)
1
135
155
57
68
RA2845
(R1/2)
1
135
155
57
68
RA2845
(15mm)
(R1/2)
T�LI� 4
Coverage Area
Flow
Pressure
Max. Area
Rate
psi (bar)
Width x Length
gpm
L/min
K =5.6 (80)
ft. x ft.
m x m
26
98.4
21.6 (1,5)
16 x 16
4.9 x 4.9
33
125.0
34.7 (2,4)
18 x 18
5.5 x 5.5
40
151.4
51.0 (3,5)
20 x 20
6.0 x 6.0
(1) 135 (57 only.
Model F1 FR56 Recessed Quick Response Extended Coverage Pendent Sprinkler
Deflector: EC
Installation Wrench: Model GFR2 Sprinkler Wrench
Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy
1--- a. —n_a: r1.. +..
(1) See table 1 for Coverage Area.
2 1/4" HOLE DIA.
[57. 15mm]
1 15116" DIA
[49.21mm]
1 X 3/4" REDUCER
TURN COLLAR OR
UNTIL TIGHT 1' X 112" REDUCER
AGAINST SPRINKLER
WRENCH BOSS (—
FACE OF FITTING TO (2)
ADJUSTMENT
CEILING DIMENS
(IK2) [3. 1Bmm]
(2)
i1"
2 27132 DIA. 028FGO iA
[72.23mm]
Model F1 FR56 QREC F1 /F2
Fig. I
(') When installed directly into a tee, the escutcheon adjustment
will be reduced.
(2) Refer to escutcheon data table for approvals and dimensions.
2 518" 041. [66.7mm]
HOLE IN CEILING
Temperature
Sprinkler
Nominal
Thread
"K" Factor
Sprinkler
Approval
Rating
Identification
Orifice
Size
Length
Organizations
Numbers (SIN)
of
oC
1 " X 112" REDUCER
US
Metric
\ I I
Y2"
1 h" NPT
5.6
80
2.25"
1
135
155
57
68
RA2845
(15mm)
(R1/2)
TO FACE OF CEILING
(57mm)
DIMENSION
(1) See table 1 for Coverage Area.
2 1/4" HOLE DIA.
[57. 15mm]
1 15116" DIA
[49.21mm]
1 X 3/4" REDUCER
TURN COLLAR OR
UNTIL TIGHT 1' X 112" REDUCER
AGAINST SPRINKLER
WRENCH BOSS (—
FACE OF FITTING TO (2)
ADJUSTMENT
CEILING DIMENS
(IK2) [3. 1Bmm]
(2)
i1"
2 27132 DIA. 028FGO iA
[72.23mm]
Model F1 FR56 QREC F1 /F2
Fig. I
(') When installed directly into a tee, the escutcheon adjustment
will be reduced.
(2) Refer to escutcheon data table for approvals and dimensions.
Fig, 2
2.
2 518" 041. [66.7mm]
HOLE IN CEILING
2 5116" DIA. [58.7mm]
CUP
r a
I
1 " X 112" REDUCER
\ I I
CEILING
(��
Q
FACE OF FITTING
TO FACE OF CEILING
I LLLLLL��
DIMENSION
1 +
(2)
ADJUSTMENT
I
A (2)
018FG07A
Model F1 FR56 QREC FP
Fig, 2
2.
Model F1 FR -56 Quick Response Extended Coverage Horizontal Sidewall Sprinkler
Deflector: EC -8
Installation Wrench: Model D Sprinkler Wrench
Approval Type: Quick Response Extended Coverage -Light Hazard Occupancy
1.,_ —+nIlnfinn Rata•
IIIV �NIIM
Nominal
Orifice
�I VI• �w-w.
Thread
Size
"K" Factor
Sprinkler
Length
Approval
Organizations
Temperature
Rating
S
Identification
Number (SIN)
US
Metric
UL
FM
135 °F (57°C)
FM
' /z"
' /z" NPT
5.6
80
2'86
1, 2
155 °F (68 °C)
RA2865
(15mm)
(R
26.6 (1,8)
28.5 (2,0)
(73mm)
4 - 12 (102 - 305)
175 °F (79 °C)
33 (125.0)
Model F1 FR -56 Recessed Quick Response Extended Coverage Horizontal Sidewall Sprinkler
Deflector: EC -8
Installation Wrench: Model GFR2 Sprinkler Wrench
Approval Type: Quick Response Extended Coverage -Light Hazard Occupancy
Inc +�Il� +inn data•
IIIV�MIIM
Nominal
Orifice
••v•• �w
Thread
Size
-w.
"K" Factor
Sprinkler
Length
Approval(
Organizations
Temperature "�
Rating
Sprinkler
Identification
Number (SIN)
US
Metric
UL
FM
135 °F (57 °C)
FM
/z"
Y2" NPT
5.6
80
2'86
1, 2
155 °F (68 °C)
RA2865
(15mm)
(R 112)
26.6 (1,8)
28.5 (2,0)
(73mm)
4 - 12 (102 - 305)
175 °F (79 °C)
33 (125.0)
(1) FM Approval of recessed sprinkler - 135 °F (57 °C) only
(2) Refer to escutcheon data table for approvals and dimensions.
COVERAGE AREA
Flow Rate
Pressure
Maximum
Deflector to Ceiling
gpm (Umin)
psi (bar)
Coverage Area
Width x Length
Dimension
Min. - Max.
UL
FM
UL
FM
ft. x ft. (m x m)
Inches (mm)
26 (98.4)
26 (98.4)
21.4 (1,5)
21.4 (1,5)
16 x 16 (4.9 x 4.9)
4 - 12 (102 - 305)
29 (109.8)
30 (113.6)
26.6 (1,8)
28.5 (2,0)
16 x 18 (4.9 x 5.5)
4 - 12 (102 - 305)
32 (121.1)
33 (125.0)
32.4 (2,2)
34.5 (2,4)
16 x 20 ( 4.9 x 6.0
1 4 - 12 (102 - 305)
OF FlrnNC rD (')
FACE
CEILING DIMENSION 4" TO 12"
TURN SPRING COLLAR
UNTIL T/GHT AGA/NSr
SPRINKLER WRENCH
BOSS. -
l 15/76" _ 2 27132' &A. DIA.
L LECOMMENDED
WALL HOLE
2 1/4" DIAMETER n
Model F1 FR56 QREC HSW EC -8
Fig. 3
(2) Refer to escutcheon data table for dimensions.
3.
Model F1 FR56 Quick Response Extended Coverage Concealed Pendent Sprinkler
Installation Wrench: Model RC1 Sprinkler Wrench
Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy
Technical Data:
Nominal
Thread
" K" Factor
Approval
PP
Sprinkler
Identification
Size
Model
Orifice
Size
US
Metric
Organizations
Number SIN
1/2"
1/2"
5.6
80
1
RA2845
15mm
R1 2
38 °C
COVER PLATE -
1/2" NPT
F1FR
Thread
Tem . Ratin
Max. Ceiling
Bulb
Size
Model
Temp.
Color
Sprinkler
Cover
1/2" NPT
F1FR
135 °F
135 °F
100 °F
Orange
R12
QREC
57 °C
57 °C
38 °C
COVER PLATE -
1/2" NPT
F1FR
155 °F
135 °C
100 °F
Red
R12
QREC
I 68 °C
57 °C
38 °C
Coveracie Area
Pressure
Max. Enclosure Area
Flow Rate
p si bar
Width x Length
ft. x ft. m x m
m (um)
K=5.6 80
26 (98.4)
21.6 (1,5)
16 x 16 (4.9 x 4.9)
33 (125.0)
34.7 (2,4)
18 x 18 (5.5 x 5.5)
40 151.4
51.0 35
20x20 6.0x6.0
(1) 135 °F (57 °C) Only
Note: 1 bar = 100 kPa
i" x 112" REDUCING
TEE OR ELBOW
-�
2 5118" DIA.
2 5116" DIA -
HOLE IN CEILING
CUP
1 112" MAX.
.��
;L
FACE OF FITTING
CEILING
5116 MAX.
COVER ADJUSTMENT
TO FACE OF CEILING
f�
DIMEN SION
ASSEMBLY 3 5116"
DIA.
CEILING
112" MAX.
-
15116"
COVER ADJUSTMENT
COVER PLATE -
ASSEMBLY 3 5/16"
DIA.
SPRINKLER
1/2" ADJUSTMENT
Fig. 4
Installation Aid:
A protective cap is included for use during installation.
Installation
Quick response sprinkler are intended for installation as
specified in NFPA 13. Quick response sprinklers and stan-
dard response sprinklers should not be intermixed.
The Model F1 FR56 Recessed QREC Sprinklers are to be
installed as shown. The Model F1 or F2 Escutcheons il-
lustrated are the only recessed escutcheons to be used
with the Model F1 FR56 EC Sprinklers. The use of any other
recessed escutcheon will void all approvals and negate all
warranties.
When installing Model F1 FR56 QREC Sprinklers, use the
Model D Sprinkler Wrench. When installing Model F1FR
QREC Recessed Pendent or Sidewall Sprinklers, use the
Model GFR2 Sprinkler Wrench. Any other type of wrench
may damage these sprinklers.
1" x 112" REDUCING
TEE OR ELBOW
-�
r- 2 51 DIA.
2 5116' DIA -
HOLE IN CEILING
CUP
�
1 1/2" MAX.
.��
;L
FACE OF FITTING
_ TO FACE OF CEILING
T :::: DIMENSION
CEILING
5116 MAX.
COVER ADJUSTMENT
314"
COVER PLATE -
ASSEMBLY 3 5116"
DIA.
SPRINKLER
5/16"
ADJUSTMENT
Fig. 5
Model F1FR56 QREC Concealed Sprinklers use 135 °F
(57 °C) or 155 °F (68 °C) Model F1 FR QREC Pendent Sprin-
klers with a threaded Model CCP cup which is factory at-
tached to the sprinkler. The assembly is completed by the
installation of the attractive, low profile, 135 °F (57 °C) rated
cover plate assembly. The cover plate and sprinkler cup
are joined using a flexible tooth threaded engagement. A
choice of two cover plate assemblies provides either 1 12"
(13mm) or 5 /8" (8mm) of cover adjustment.
Do not install these sprinklers in ceilings which have pos-
itive pressure in the space above.
The sprinkler cup is factory attached to the Model F1 FR56
QREC Sprinkler. A Teflon* -based thread sealant should be
applied to the sprinkler threads only.
* DuPont Registered Trademark.
4
After ,a 2 5 /8 (67mm) inch diameter hole is cut in the ceil-
ing, the sprinkler is easily installed with the Model RC1
Wrench. When installing a sprinkler, the protective cap
is removed and the wrench is positioned into the sprin-
kler /cup assembly until the two wrench faces engage the
wrenching flats on the Model FlFR56 QREC Sprinkler.
The sprinkler is then tightened into the pipe fitting. When
inserting or removing the wrench from the sprinkler /cup
assembly, care should be taken to prevent damage to
the sprinkler. DO NOT WRENCH ON ANY OTHER PART
OF THE SPRINKLER. The cover plate assembly is then
pressed into the cup. Final adjustment is made by turning
the cover plate until the skirt flange makes full contact with
the ceiling surface. Cover plate removal requires turning in
the counter clockwise direction.
After installation, inspect all sprinklers to ensure that
there is a gap between the cover plate and ceiling and
that the four cup slots are open and free from any air flow
impediment to the space above.
Concealed cover plate /cup assemblies are listed only
for use with specific sprinklers. The use of any other con-
cealed cover plate /cup assembly with the Model FlFR56
QREC Pendent Sprinkler or the use of the Model CCP con-
cealed cover plate assembly on any sprinkler with which
it is not specifically listed may prevent good fire protection
and will void all guarantees, warranties, listings and ap-
provals.
Glass bulb sprinklers have orange bulb protectors to
minimize bulb damage during shipping, handling and
installation. REMOVE THIS PROTECTION AT THE TIME
THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR
FIRE PROTECTION. Removal of the protectors before this
time may leave the bulb vulnerable to damage. RASCO
wrenches are designed to install sprinklers when covers
are in place. REMOVE PROTECTORS BY UNDOING THE
CLASP BY HAND, DO NOT USE TOOLS TO REMOVE
THE PROTECTORS.
Maintenance
The Models FlFR56 QREC and FlFR56 QREC Re-
cessed Sprinklers should be inspected quarterly and the
sprinkler system maintained in accordance with NFPA
25. Do not clean sprinklers with soap and water, ammo-
nia or any other cleaning fluids. Remove dust by using
a soft brush or gentle vacuuming. Remove any sprinkler
which has been painted (other than factory applied) or
damaged in any way. A stock of spare sprinklers should
be maintained to allow quick replacement of damaged or
operated sprinklers. Prior to installation, sprinklers should
be maintained in the original cartons and packaging until
used to minimize the potential for damage to sprinklers
that would cause improper operation or non - operation.
Escutcheon Data:
(1) EC Pendent.
(2) EC HSW.
Temnprature Rating
Sprinkler (
Maximum
Face of Fitting
Escutcheon
Adjustment
«p
Dimension
to Ceiling
Model
Temperature
Tem rature
Wail Dimension
Max Recessed
1 1 12" (38.1 mm) (1)
3 /16 ' - 15 /,6'
F1
Min Recessed
3/4" 19.1 mm (2)
5m - 24mm
57
Max Recessed
1 1 /2" (38.1 mm) (1)
3/16' - 11/16'
F2
Min Recessed
1" 25mm (2
5m - 17mm
FP Push -0N
Max Recessed
'/ 18 " (11mm)
1 1 /2" (38.1 mm)
Thread off
Min Recessed
15 16" 24mm
1" 25mm
(1) EC Pendent.
(2) EC HSW.
Temnprature Rating
Finishes (1)
Standard Finishes
Sprinkler (
Maximum
Coverplate
Bronze
Sprinkler
Ambient
Bulb
Classification
Temperature
Tem rature
Color
Special Application Finishes
OF
o C
CF
'C
Ordinary
135
57
100
38
Orange
Ordinary
155
68
100
38
Red
Finishes (1)
Standard Finishes
Sprinkler (
Escutcheon
Coverplate
Bronze
Brass
Chrome
Chrome Plated
Chrome Plated
White
White & Black Polyester Coated
White Painted
Special Application Finishes
Sprinkler (2)
Escutcheon
Coverplate
Bright Brass
Bright Brass
Bright Brass
Black Plating
Black Plating
Black Plating
Black Paint
Black Paint
Black Paint
Off White
Off White
Off White
Satin Chrome
Satin Chrome
(1) Other colors and finishes are available on special order. Consult tactory
for details. I
(2) FM Approvals limited to Bronze, Bright Brass, Satin Chrome Plated,
Black Plated and Polyester Coated.
Note: Paint or any other coating applied over the factory finish will void
approvals and waranties.
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Deflector Type
5. Temperature Rating
6. Sprinkler Finish
7. Escutcheon Finish (where applicable)
8. Coverplate Finish (where applicable)
9. Coverplate Finish (where aplicable)
10. Coverplate Adjustment
11. Coverplate Thread Size
12. Coverplate Temperature Rating
Note: When Model FlFR56 QREC Recessed sprinklers are ordered,
the sprinklers, escutcheons and coverplates are packaged
separately.
5.
Reliable,,,For C Protection
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision -made Reliable products that guard life and property from fire around the clock.
• Automatic sprinklers
• Flush automatic sprinklers
• Recessed automatic sprinklers
• Concealed automatic sprinklers
• Adjustable automatic sprinklers
• Dry automatic sprinklers
• Intermediate level sprinklers
• Open sprinklers
• Spray nozzles
• Alarm valves
• Retarding chambers
• Dry pipe valves
• Accelerators for dry pipe valves
• Deluge valves
• Detector check valves
• Check valves
• Electrical system
• Sprinkler emergency cabinets
• Sprinkler wrenches
• Sprinkler escutcheons and guards
• Inspectors test connections
• Sight drains
• Ball drips and drum drips
• Control valve seals
• Air maintenance devices
• Air compressors
• Mechanical sprinkler alarms
• Electrical sprinkler alarm switches
• Water flow detectors
• Pressure gauges Identification signs
• Fire department connection
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Prod uctsmanuf actu red and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
Rel , a The Reliable Automatic Sprinkler Co., Inc. ®Recycled
® (800) 431 -1588 Sales Offices Paper
(800) 848 -6051 Sales Fax Revision lines indicate updated or new data.
(914) 829 -2042 Corporate Offices
www.reliablesprinkler.com Internet Address EG Printed in U.S.A 08/10 P/N 9999970388
Rellablia
Bulletin 028 Rev. A
M
C
Model F1 FR Series
D
Quick Response °
c
Extended Coverage Spray.
D
A complete line of UL Listed and FM Approved
quick response extended coverage sprinklers
for light hazard applications.
Horizontal Sidewall Sprinklers are approved
for installation 4" to 12" (102mm - 305mm)
Model F1 FR56 QREC Sprinkler Types
Pendent
Horizontal Sidewall EC -8
Model F1 FR56 QREC Recessed Sprinkler Types
Recessed Extended Coverage Pendent F1 /F2 /FP
Recessed Extended coverage Horizontal Sidewall
Model F1 FR56 QREC Concealed
Extended Coverage Pendent
Approval Organizations
1. Listed by Underwriters Laboratories, Inc. and
Certified for Canada (cULus)
2. Factory Mutual Approvals (FM)
UL Listing Category
Sprinklers, Automatic & Open
Quick Response Extended Coverage Sprinkler (VNIV)
Product Description
Reliable Models F1 FR56 QREC and F1 FR56 QREC Re-
cessed Sprinklers are quick response sprinklers which
combine the durability for a standard sprinkler with the at-
tractive low profile of a decorative sprinkler.
The Models F1 FR56 QREC and F1 FR56 QREC Recessed
Automatic Sprinklers utilize a 3.Omm frangible glass bulb.
These sprinklers have demonstrated response times in
laboratory tests which are five times faster than standard
response sprinklers. This quick response enables these
sprinklers to apply water to a fire much faster than stan-
dard sprinklers of the same temperature rating.
Model F1 FR56 QREC Quick Response Extended Cover-
age Concealed Sprinkler is an attractive, low profile con-
cealed sprinkler assembly. This sprinkler assembly uti-
lizes a Model F1 FR56 QREC pendent sprinkler in a Model
CCP cup and push -on thread -off cover plate assembly.
The cup is securely factory threaded on the sprinkler's in-
let end. The assembly is shipped with a protective cap.
The sprinkler and cup are easily installed into the sprinkler
fitting using the Model RC1 Sprinkler Wrench. The cover
plate assembly is attached to the sprinkler cup using a
flexible tooth threaded engagement. The cover plate is
attached to the skirt using 135 °F (57 °C) ordinary tempera-
ture classification solder.
Extended Coverage Recessed Extended
Pendent Coverage Pendent F1/F2
Extended Coverage Extended Coverage
Pendent Concealed Horizontal Sidewall EC -8
When the ceiling temperature rises, the solder holding
the cover plate melts, allowing the release of this part and
thus exposing the Model F1 FR56 QREC sprinkler inside to
the rising ambient temperature.
The Temperature rating of the sprinkler identified by the
color of the glass bulb.
The glass bulb consists of an accurately controlled
amount of special fluid hermetically sealed inside a pre-
cisely manufactured glass capsule. This glass bulb is spe-
cially constructed to provide fast thermal response.
Application
Quick response sprinklers are used in fixed fire protection
systems: Wet, Dry, Deluge or Preaction. Care must be exer-
cised that the orifice size, temperature rating, deflector style
and sprinkler type are in accordance with the latest published
standards of the National Fire Protection Association or the ap-
proving authority having jurisdiction. Quick response sprinklers
are intended for installation as specified in NFPA 13.
The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Recessed Extended
Coverage Horizontal
Sidewall EC -8
Model F1 FR56 Quick Response Extended Coverage Pendent Sprinkle
Deflector: EC
Installation Wrench: Model D Sprinkler Wrench
Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy
n _ 1
1110 G1 1Q
1 11 vwaw.
Pressure
Max. Area
Rate
Temperature
Sprinkler
Nominal
Thread
"K" Factor
Sprinkler
Approval
Rating
Identification
Orifice
Size
Length
Organizations
Numbers (SIN)
34.7 (2,4)
18 x 18
of
oC
151.4
51.0 (3,5)
US
Metric
1 /2"
1 12" NPT
5.6
80
225"
1
135
155
57
68
RA2845
(15mm)
(131/2)
(57mm)
'r-ki– 1
Coverage Area
Flow
Pressure
Max. Area
Rate
psi (bar)
Width x Length
gpm
L/min
K =5.6 (80)
ft. x ft.
m x m
26
98.4
21.6 (1,5)
16x16
4.9x4.9
33
125.0
34.7 (2,4)
18 x 18
5.5 x 5.5
40
151.4
51.0 (3,5)
20 x 20
6.0 x 6.0
(1) 135 °F (57 °C) only.
Model F1 FR56 Recessed Quick Response Extended Coverage Pendent Sprinkler
Deflector: EC
Installation Wrench: Model GFR2 Sprinkler Wrench
Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy
IIIJawIIw
aIV1• rw�v•
Temperature
Sprinkler
Nominal
Thread
"K" Factor
Sprinkler
Approval
Rating
Identification
Orifice
Size
Length
Organizations
Numbers (SIN)
of
oC
US
Metric
1 /2"
1 /2 " NPT
5.6
80
2.25"
1
135
155
57
68
RA2845
(15mm)
(R1/2)
(57mm)
(1) See table 1 for Coverage Area.
2 114' HOLE DIA.
[57. 15mm]
1 15/16' DIA
[49.21 mm]
1' X 3/4" REDUCER
TURN COLLAR T OR
UNTIL TIGHT I I' X 1/2' REDUCER
AGAINST SPRINKLER
WRENCH BOSS r \ –
I FACE OF FITTING TO
CEILING DIMENSION (2)
vii 1/8
(IK21 (3. 18mm]
ADJUSTMENT
(2)
ii '
2 27132 DIA.
[72.23mm] 028FGO IA
Model F1 FR56 QREC F1 /F2
Fig. 1
(1) When installed directly into a tee, the escutcheon adjustment
will be reduced.
( 2) Refer to escutcheon data table for approvals and dimensions.
2 516' DIA. [66.7mm]
HOLE IN CEILING
2 5116' DIA. [56-7m-]
CUP
I
r_� — �
I �
� � I
\ I I
r�
1' X 1/2' REDUCER
CEILING T (2J
J FACE OF nMNG
TO FACE OF CEILING
DIMENSION
1
(2)
(2) I A
ADJUSTMENT
02dFC07A
Model F1 FR56 QREC FP
Fig 2
2.
Model F1 FR -56 Quick Response Extended Coverage Horizontal Sidewall Sprinkler
Deflector: EC -8
Installation Wrench: Model D Sprinkler Wrench
Approval Type: Quick Response Extended Coverage -Light Hazard Occupancy
Installation Data:
" Sprinkler
al Thread Sprinkler Approval Temperature Identification
Orifice Size US Length Organizations Rating Nu mber (SIN)
135'F (57°C)
1 /2" /2 NPT 2.86" 1,2 155 °F (68 °C) RA2865
(15mm) (R1/2) 5.6 80 (73mm) 175'F (79 °C)
•
Model F1 FR -56 Recessed Quick Response Extended Coverage Horizontal Sidewall Sprinkler
Deflector: EC -8
Installation Wrench: Model GFR2 Sprinkler Wrench
Approval Type: Quick Response Extended Coverage -Light Hazard Occupancy
r,_/<_
ulsl�tuauv��
•.Q•u.
Min. - Max.
ft. x ft. (m x m)
Inches (mm)
Sprinkler
Nominal
Thread
"K" Factor
Sprinkler
Approval (2)
Temperature �,�
Identification
US
Metric
Orifice
Size
Length
Organizations
Rating
Number (SIN)
135 °F (57 °C)
1 /2"
1 12" NPT
5.6
80
2.86"
1,2
155 °F (68 °C)
RA2865
05mm)
(RY2)
(73mm)
175 °F (79 °C)
(') FM Approval of recessed sprinkler - 135 °1- tbl'U) onq
( Refer to escutcheon data table for approvals and dimensions.
Flow Rate
gpm (Umin)
UL FM
COVERAGE AREA
Pressure Maximum Deflector to Ceiling
psi (bar) Coverage Area Dimension
UL
26 (98.4) 26 (98.4) 21.4 (1,5)
29 (109.8) 30 (113.6) 26.6 (1,8)
32 (121.1) 33 (125.0) 32.4 (2,2)
FACE OF FITTING TO (2)
CEILING DIMENSION
F -M
=\\
�
4" TO 12'
TURN SPRING COLLAR
UNTIL TIGHT AGAINST
SPRINKLER WRENCH
BOSS.
2 17131' DIA.
115/16"
DO. +1
L IL -+
L RECOMMENDED
WALL L HOLE
L
1 1 H DIAMETER
ADJUSTMENT (2)
Model F1 FR56 QREC HSW EC -8
Fig. 3
(2) Refer to escutcheon data table for dimensions.
3.
028FCO3
x Length
Min. - Max.
ft. x ft. (m x m)
Inches (mm)
9(2,, Width
16 x 16 (4.9 x 4.9)
4 - 12 (102 - 305)
16 x 18 (4.9 x 5.5)
4 - 12 (102 - 305)
4)
16 x 20 ( 4.9 x 6.0
4 - 12 (102 30 5)
FACE OF FITTING TO (2)
CEILING DIMENSION
F -M
=\\
�
4" TO 12'
TURN SPRING COLLAR
UNTIL TIGHT AGAINST
SPRINKLER WRENCH
BOSS.
2 17131' DIA.
115/16"
DO. +1
L IL -+
L RECOMMENDED
WALL L HOLE
L
1 1 H DIAMETER
ADJUSTMENT (2)
Model F1 FR56 QREC HSW EC -8
Fig. 3
(2) Refer to escutcheon data table for dimensions.
3.
028FCO3
Model F1 FR56 Quick Response Extended Coverage Concealed Pendent Sprinkler
Installation Wrench: Model RC1 Sprinkler Wrench
Approval Type: Quick Response Extended Coverage - Light Hazard Occupancy
Tpr_hnical Data:
Nominal
Thread
"K" Factor
Approval
Pp
Sprinkler
Identification
Size
Model
Orifice
Size
US
Metric
Organizations
Number SIN
1/2"
1/2"
5.6
80
1
RA2845
15mm
R1 2
38'C
COVER PLATE —
1/2" NPT
F1FR
Thread
Temp Rating
Max. Ceiling
Bulb
Size
Model
Temp.
Color
Sprinkler
Cover
1/2" NPT
F1FR
135 °F
135 °F
100 °F
Orange
R12
QREC
57 °C
57'C
38'C
COVER PLATE —
1/2" NPT
F1FR
155 °F
135 °C
100 °F
Red
R12
QREC
68 °C
57°C
38 °C
Coverage Area
Pressure
Max. Enclosure Area
Flow Rate
p si bar
Width x Length
ft. x ft. m x m
m Vm
K =5.6 80
26 (98.4)
21.6 (1,5)
16 x 16 (4.9 x 4.9)
33 (125.0)
34.7 (2,4)
18 x 18 (5.5 x 5.5)
40 151.4
51.0 35
20x20'I 6.0x6.0 "I
(1) 135 °F (57 °C) Only
Note: 1 bar = 100 kPa
1" x 112" REDUCING
TEE OR ELBOW
2 518" DIA.
2 5116" DIA —
HOLE IN CEILING
J
CUP
- -- T
1 1/2" MAX.
A
FACE OF FITTING
TO FACE OF CEILING
DIMENSION
CEILING
1/2" MAX.
COVER ADJUSTMENT
COVER PLATE —
ASSEMBLY 3 5/16"
DIA.
SPRINKLER —�
1/2" ADJUSTMENT
awrm
Fig. 4
I' x 112" REDUCING
TEE OR ELBOW
- r - 2 5/8" DIA.
2 5116" D41A HOLE IN CEILING
CUP
1 112" MAX.
FACE OF FITTING
_ ._ . TO FACE OF CEILING
7.: :�i ON
CEILING 5/16" MAX. 3/4"
COVER ADJUSTMEN PLATE
ASSEMBLY 3 5116" DIA.
SPRINKLER —�
5/16" ADJUSTMENT nwma
Fig. 5
Installation Aid:
A protective cap is included for use during installation.
Installation
Quick response sprinkler are intended for installation as
specified in NFPA 13. Quick response sprinklers and stan-
dard response sprinklers should not be intermixed.
The Model F1 FR56 Recessed QREC Sprinklers are to be
installed as shown. The Model F1 or F2 Escutcheons il-
lustrated are the only recessed escutcheons to be used
with the Model F1 FR56 EC Sprinklers. The use of any other
recessed escutcheon will void all approvals and negate all
warranties.
When installing Model F1FR56 QREC Sprinklers, use the
Model D Sprinkler Wrench. When installing Model F1FR
QREC Recessed Pendent or Sidewall Sprinklers, use the
Model GFR2 Sprinkler Wrench. Any other type of wrench
may damage these sprinklers.
Model F1 FR56 QREC Concealed Sprinklers use 135 °F
(57 °C) or 155 °F (68 °C) Model F1 FR QREC Pendent Sprin-
klers with a threaded Model CCP cup which is factory at-
tached to the sprinkler. The assembly is completed by the
installation of the attractive, low profile, 135 °F (57 °C) rated
cover plate assembly. The cover plate and sprinkler cup
are joined using a flexible tooth threaded engagement. A
choice of two cover plate assemblies provides either 1 12 "
(13mm) or 5 /8 " (8mm) of cover adjustment.
Do not install these sprinklers in ceilings which have pos-
itive pressure in the space above.
The sprinkler cup is factory attached to the Model F1 FR56
QREC Sprinkler. A Teflon" -based thread sealant should be
applied to the sprinkler threads only.
' DuPont Registered Trademark.
4.
After a 2 5 /8 (67mm) inch diameter hole is cut in the ceil-
ing, the sprinkler is easily installed with the Model RC1
Wrench. When installing a sprinkler, the protective cap
is removed and the wrench is positioned into the sprin-
kler /cup assembly until the two wrench faces engage the
wrenching flats on the Model F1FR56 QREC Sprinkler.
The sprinkler is then tightened into the pipe fitting. When
inserting or removing the wrench from the sprinkler /cup
assembly, care should be taken to prevent damage to
the sprinkler. DO NOT WRENCH ON ANY OTHER PART
OF THE SPRINKLER. The cover plate assembly is then
pressed into the cup. Final adjustment is made by turning
the cover plate until the skirt flange makes full contact with
the ceiling surface. Cover plate removal requires turning in
the counter clockwise direction.
After installation, inspect all sprinklers to ensure that
there is a gap between the cover plate and ceiling and
that the four cup slots are open and free from any air flow
impediment to the space above.
Concealed cover plate /cup assemblies are listed only
for use with specific sprinklers. The use of any other con-
cealed cover plate /cup assembly with the Model F1 FR56
QREC Pendent Sprinkler or the use of the Model CCP con-
cealed cover plate assembly on any sprinkler with which
it is not specifically listed may prevent good fire protection
and will void all guarantees, warranties, listings and ap-
provals.
Glass bulb sprinklers have orange bulb protectors to
minimize bulb damage during shipping, handling and
installation. REMOVE THIS PROTECTION AT THE TIME
THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR
FIRE PROTECTION. Removal of the protectors before this
time may leave the bulb vulnerable to damage. RASCO
wrenches are designed to install sprinklers when covers
are in place. REMOVE PROTECTORS BY UNDOING THE
CLASP BY HAND. DO NOT USE TOOLS TO REMOVE
THE PROTECTORS.
Maintenance
The Models F1 FR56 QREC and F1 FR56 QREC Re-
cessed Sprinklers should be inspected quarterly and the
sprinkler system maintained in accordance with NFPA
25. Do not clean sprinklers with soap and water, ammo-
nia or any other cleaning fluids. Remove dust by using
a soft brush or gentle vacuuming. Remove any sprinkler
which has been painted (other than factory applied) or
damaged in any way. A stock of spare sprinklers should
be maintained to allow quick replacement of damaged or
operated sprinklers. Prior to installation, sprinklers should
be maintained in the original cartons and packaging until
used to minimize the potential for damage to sprinklers
that would cause improper operation or non - operation.
Escutcheon Data:
(1) EC Pendent.
(2) EC HSW,
Temperature Rating
Classification
Sprinkler
Temperature
Maximum
Ambient
Tem rature
Face of Fitting
Escutcheon
Adjustment
«
to Ceiling
Model
Ordinary
Ordinary
Dimension
Wall Dimension
100 38
1 100 38
Max Recessed
1 1 /2" (38.1 mm) (')
3 - 15 / 1 s '
F1
Min Recessed
3 /4" 19.1 mm c2i
5m - 24mm
Bright Brass
Max Recessed
1 (38.1 mm) (')
3 /15 " - 11 /15 "
F2
Min Recessed
I 1" 25mm c2>
5m - 17mm
FP Push -on/
Max Recessed
1 /16" (11 mm)
1
1 1 /2" (38.1 mm)
Thread -off
Min Recessed
15 /
1" 25mm
(1) EC Pendent.
(2) EC HSW,
Temperature Rating
Classification
Sprinkler
Temperature
Maximum
Ambient
Tem rature
Bulb
Color
Bronze
O F
Oc
OF OC
Chrome Plated
Ordinary
Ordinary
135
155
57 1v
68
100 38
1 100 38
Orange
Red
Finishes (1)
Standard Finishes
Sprinkler (2)
Escutcheon
Coverplate
Bronze
Brass
Chrome
Chrome Plated
Chrome Plated
White
White & Black Polyester Coated
White Painted
SDecial Application Finishes
Sprinkler (Z)
Escutcheon
Coverplate
Bright Brass
Bright Brass
Bright Brass
Black Plating
Black Plating
Black Plating
Black Paint
Black Paint
Black Paint
Off White
Off White
Off White
Satin Chrome
I Satin Chrome
( Other colors and finishes are available on special order. Consult factory
for details.
(2) FM Approvals limited to Bronze, Bright Brass, Satin Chrome Plated,
Black Plated and Polyester Coated.
Note: Paint or any other coating applied over the factory finish will void
approvals and waranties.
Ordering Information
Specify:
1. Sprinkler Model
2. Sprinkler Type
3. Orifice Size
4. Deflector Type
5. Temperature Rating
6. Sprinkler Finish
7. Escutcheon Finish (where applicable)
8. Coverplate Finish (where applicable)
9. Coverplate Finish (where aplicable)
10. Coverplate Adjustment
11. Coverplate Thread Size
12. Coverplate Temperature Rating
Note: When Model FlFR56 QREC Recessed sprinklers are ordered,
the sprinklers, escutcheons and coverplates are packaged
separately.
91
Reiiable...For Complete P rotect i o n
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision -made Reliable products that guard life and property from fire around the clock.
• Automatic sprinklers
• Flush automatic sprinklers
• Recessed automatic sprinklers
• Concealed automatic sprinklers
• Adjustable automatic sprinklers
• Dry automatic sprinklers
• Intermediate level sprinklers
• Deluge valves
• Detector check valves
• Check valves
• Electrical system
• Sprinkler emergency cabinets
• Sprinkler wrenches
• Sprinkler escutcheons and guards
• Open sprinklers
• Spray nozzles
• Alarm valves
• Retarding chambers
• Dry pipe valves
• Accelerators for dry pipe valves
• Mechanical sprinkler alarms
• Electrical sprinkler alarm switches
• Water flow detectors
• Inspectors test connections
• Sight drains
• Ball drips and drum drips
• Control valve seals
• Air maintenance devices
• Air compressors
• Pressure gaugesldentification signs
• Fire department connection
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
Manufactured by
The Reliable Automatic Sprinkler Co., Inc. ® Recycled
(800) 431 -1588 Sales Offices Paper
' (800) 848 -6051 Sales Fax Revision lines indicate updated or new data.
(914) 829 -2042 Corporate Offices
www.reliablesprinkler.com Internet Address EG. Printed in U.S.A 08/10 PM 9999970388
CAT,P%I.C' C
l 'I
co
a
Copper Fittings
n
wv..connect
W you need is
o nm C0 p
....r• rr +.—r r�*wr ax: we , .--
or.1`I�q W.M Wtrw+rwl►+w M
krIt-
IRA r1 oduct3
.atWnW C rinr.{ rt9 "t [ My SR.rvpa co n.w,
ww4m
IWO
The "New Products" page is a
continuously updated showcase
for new products by NIBCO.
Current highlights include:
• Compact Economy Ball Valves
• Prepackaged Pneumatic Ball Valves
• Circuit Balancing Valves
• Flanged Butterfly Valves
• Bronze Ball Valve Line Extension
• PEXlink- copper fittings for PEX applications
• Just Right hot -water circulation device
• Carbon /Stainless Steel Ball Valves
• Socket Fusion Equipment
• TruConnectg fittings for Chem -Aire
melco rtner
t�ae*;•r...� B .
. ..........
c r.rt •
�rerrtt
w.ar ta�q�rre
The "Fittings" Homepage at
www.nibco.com provides easy
access to valuable reference tools.
k Key information includes:
• Price sheets (PDF & Excel format)
—also accessible from home page
• Downloadable catalogs (PDF format)
• Product drill -down capabilities to categories
• Wrot Copper & Cast Bronze Fittings
• ABS & PVC Drain, Waste, & Vent
• PVC Schedule 40 Fittings & Valves
• CPVC CTS Fittings
( 2 N,BC0
N
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH:1.888.446.4226 • FAX: 1.800.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
www nihrn rnm
ADWV 0304
N
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH:1.888.446.4226 • FAX: 1.800.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
www nihrn rnm
Cast Copper Alloy Flared Fittings . . . . ............. . .. . .....
22 -24
Copper Insert Fittings for PEXlink . . . ...... . ... . ...... . .. . .
25 -27
Copper Insert Fittings for Polybutylene ..... . ...............
28 -29
Engineering Data ............. ..........................41
-84
Frequently -Asked Questions ..... . . ... . .. . . .... . ... . .. . ...
. . . 90
Installation Instructions ... ...............................
85 -89
Numerical Index ............. .............................92
Specifications ............... ..............................4
Warranty ................... .............................91
Wrot & Cast DWV Fittings ...............................
30 -40
Wrot & Cast Pressure Fittings .............................
5 -21
1509001:2000
The manufacturing plants at
South Glens Falls, NY,
Stuarts Draft, V& Nacogdoches, TX
and Reynosa, Mexico manufacture
products under a Quality
Management System conforming
to the anent revision of ISO -9001
International Standards
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
SpecifiIM
cations
All of the advantages found in copper as a metal have been capitalized to the utmost in the manufacture of NIBCO Fittings. Because
of the accuracy of construction and design, copper plumbing is more efficient and less expensive.
NIBCO manufactures nine general types of fittings: Wrot Pressure; Cast Pressure; Wrot Drainage; Cast Drainage; Flanges; Flared
Tube; Threaded Bronze; Insert Fittings for PEX; Barbed Insert Fittings for Polybutylene. Each has its particular place and use and each
offers its own advantages when used for the proper service requirement.
ALLOY AND FINISH — NIBCO Fittings are made from highest quality raw materials available — Cast Fittings are made from Copper
Alloy C84400 which consists of 81% Copper, 7% Lead, 3% Tin, and 9% Zinc per ASTM Specification B584. Wrot Copper Fittings are
made from commercially pure copper mill products per ASTM Specifications B75 Alloy C12200.
NIBCO fittings are produced to meet requirements of applicable standards wherever practicable.
NIBCO brand wrot and cast fittings are manufactured in the U.S.A. and Mexico. The manufacturing plants at South Glens Falls, NY,
Stuarts Draft, VA, Nacogdoches, TX and Reynosa, Mexico are registered to ISO 9002 quality standards.
Following is suggested phrasing to be incorporated in your specifications or bills of material for
Copper Tube Fittings.
WROT SOLDER JOINT FITTINGS — "Wrot Solder Joint Fittings shall be produced to one of the following specifications:
1. Material and workmanship shall be in accordance with ASME /ANSI 816.22; Wrought Copper and Copper Alloy Solder Joint
Pressure Fittings."
2. The dimensional, material and workmanship shall
meet the requirements of MSS SP -104; Wrought
Copper Solder Joint Pressure Fittings."
3. The dimensional, material and workmanship of
5 " -12" copper fittings shall meet the requirements
of MSS SP -109 "Welded Fabricated Copper Solder
Joint Pressure Fittings."
4. Certified to ANSI /NSF 61.
CAST COPPER ALLOY SOLDER JOINT FITTINGS —
"Cast Copper Alloy Solder Joint Fittings shall be in
accordance with ANSI Std. 616.18."
WROT DRAINAGE FITTINGS — "Wrot Drainage
Fittings shall be in accordance with ASME /ANSI Std.
816.29."
CAST COPPER ALLOY SOLDER JOINT DRAINAGE
FITTINGS — "Cast Copper Alloy Solder Joint Drainage
Fittings shall be in accordance with ASME Std.
816.23."
CAST COPPER ALLOY FLARED TUBE FITTINGS — "Cast
Copper Alloy Flared Tube Fittings shall be in accor-
dance with ASME /ANSI Std. 816.26.
CAST COPPER ALLOY FLANGES AND FLANGED
FITTINGS—
CLASS 150 — Cast Copper Alloy Flanges and
Flanged Fittings shall meet the requirements of
MSS SP -106 and /or the workmanship and
dimensions of Federal Specifications WW -F -406 or
ASME Std. 816.24.
CLASS 125 — Material, workmanship and
dimensions of flanges shall be in accordance with
MSS SP -106.
CAST BRONZE THREADED FITTINGS —
"Cast Bronze Threaded Fittings shall be in accordance
with ANSI /ASME 816.15."
POLYBUTYLENE COPPER INSERT TYPE VALVES AND
FITTINGS — "Wrot Copper Insert Fittings shall be
manufactured per the following specifications:
MSS SP -103 or ASTM F1380."
NIBCO Copper Tube Fittings are all produced to above
Standards. To simplify, write your specifications to
read: "Copper Tube Fittings to be in accordance with
specifications as outlined in NIBCO Catalog c -cf- 0602."
WROT COPPER MEDICAL MEDICAL GAS SYSTEM
COMPONENTS — Wrot copper fittings that are to be
installed in medical gas applications shall be prepared
in accordance with NFPA 99, Health Care Facilities Gas
and Vacuum Systems and the Compressed Gas
Association, Pamphlet G4.1. Packaging shall be
adequately protective and include labeling that
identifies the preparer and states that the product has
been cleaned and bagged for oxygen or med gas
service.
For technical information and dimensions refer to the
engineering section contained in this catalog.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Wro and Cast Pres Fi
600 Series — Wrot
700 Series — Cast
Adapters................... ............................6 -8
Air Chambers ............... ..............................8
Bulkhead Fittings ............ ..............................8
Bushings ................... ..............................8
Caps...................... ..............................9
Couplings ................... ...........................9
-11
Crosses .................... .............................11
Elbows ..................... ..........................11
-15
Fitting Reducers ............. .............................15
Flanges .................... ..........................15
-16
Plugs ...................... .............................16
Return Bends ............... .............................16
Straps ..................... .............................16
Tees....................... ..........................16
-20
Traps...................... .............................20
Unions..................... .............................21
Venturi..................... .............................21
Y's ........................ .............................21
iso�oot:xooa
The mardacturirg plants at
South Glens Falls, NY,
Stuarts Draft, VA, Nacogdoches. TX
and Rerm, Mexico manufacture
products under a Quality
Management System conforming
to the current revision of ISO -9001
International Standards
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
ADAPTERS
603
Adapter C x F - Wrot
NOM. SIZE
1/8
A�1'
NET WT./LBS.
0.03
, ,
INCHES
13 /32
1/8 x 1/4
0.03
'12
1/4
0.03
5 /8
1/4 x 3/8
0.05
21 /32
3/8
0.04
11 /16
3/8 x 1/2
0.09
29 /32
3/8 x 1/4
0.03
9 /16
112
0.09
21 /32
112 x 3/4
0.14
1
112 x 3/8
0.04
17 /32
112 x 1/4
0.05
1 /2
5/8 x 3/4
0.12
29 /32
5/8 x 112
0.11
3 /4
3/4
0.15
29 /32
3/4 x 1
0.21
1
3/4 x 112
0.10
5 /8
1
0.24
31 /32
1 x 11/4
0.28
1
1 x 3/4
0.19
25 /32
1 x 112
0.24
5 /8
1 1/4
0.33
1
1 1/4 x 1 112
0.40
1
1 1/4 x 1
0.27
31 /32
11/2
0.44
1 /8
1 112 x 2
0.50
1
2
0.63
1
2 x 1112
0.74
1
21/2
1.13
-
3
1.94
-
703
Adapter C x F - Cast
NOM. SIZE
1/4 x 112
NET WT./LBS.
0.13
1 ,
INCHES
27 /32
1/2 x 1
0.30
1
3/4 x 1 1/4
0.55
1'/8
3/4 x 3/8
0.17
3 /4
1 x 1112
0.68
13 /32
1 1/4 x 1
0.27
31 /32
1 1/4 x 3/4
0.29
3 /4
1 112 x 2
0.78
1'/32
1 1/2 x 1
0.37
25 /32
1 112 x 1 1/4
0.47
1
2 x 11/4
0.76
27 /32
2112
1.62
1
3
2.34
1
4
4.05
1
D
603 -2
Fitting Adapter Ftg x F - Wrot
1/4
0.03
1
3/8
0.06
1
112
0.09
1
112 x 3/8
0.05
1'/4
3/4
0.13
1
1
0.27
2
1 1/4
0.31
2
1 112
0.43
2
2
0.61
2
703 -2
Fitting Adapter Ftg x F - Cast
APPROX. DIM. B
NOM. SIZE NET VVT.ILBS. INCHES
112 x 1/4 0.11 1
3/4 x 112 0.12 1
1 x 3/4 0.38 1
1 x 112 0.15 1
21/2 1.65 2
3 2.47 3
703 -5 Special
Drop Adapter C x F - Cast
APP ,
NOM. SIZE NET WT./LBS. INCHES
112 0.16 3 /4
3/4 0.24 31 /32
ip
7 03-5 B
Drop Adap
APPROX. DIM. A
NOM. SIZE NET WT. /LBS. INCHES
1
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
ADAPTERS continued
III
604
Adapter C x M - Wrot
704
Adapter C x M - Cast
NOM. SIZE
1 /8 x 1 /4
APPR41A.
NET WT./LBS.
0.03
DIM.
INCHES
7 /16
1/4
0.03
23 /32
3/8
0.04
15 /32
3/8 x 3/4
0.15
1 5 /16
3/8 x 112
0.09
1
112
0.07
5 /8
112 x 1
0.25
1 1 12
112 x 3/4
0.15
13 /16
112 x 3/8
0.05
19 /32
112 x 1/4
0.07
5 /a
5/8 x 3/4
0.16
1 1 /8
5/8 x 112
0.08
3 /4
3/4
0.14
13 /16
3/4 x 1
0.26
1 7 /16
3/4 x 112
0.10
27 /32
1
0.21
31 /32
1 x 1112
0.54
29 /32
1 x 11/4
0.38
1 1 12
1 x 3/4
0.18
29 /32
1 x 112
0.18
31 /32
1 1/4
0.35
15 /16
1 1/4 x 1 112
0.51
1 19 /32
1 1/4 x 1
0.27
1 5 /32
11/2
0.44
31 /32
1 1/2 x 2
0.81
1 1 /8
1 1/2 x 1 1/4
0.38
1 3 /16
1 112 x 1
0.37
1 3 /32
2
0.81
1 3 /32
2 x 1112
0.64
1 1 /8
21/2
1.48
1 21 /32
3
1.69
-
Consult price sheet for Made to Order items and
for minimum order quantities.
N SIZE
3/4 x 11/2
NET VVT./LBS.
0.60
INCHES
1 1 '/32
3/4 x 11/4
0.38
1 7 /32
3/4 x 3/8
0.19
13 /16
1x2
1.15
-
1 x 1 1/2
0.64
29 /32
1 1/4 x 2
0.88
1 9 /32
1 1/4 x 3/4
0.30
31 /32
1 112 x 2
0.77
1 1 /8
2 x 21 12
1.57
1 15 /32
2 x 1112
0.71
1 1 /8
2x11/4
1.08
-
21 12
1.48
1 21 /32
21 12 x 2
1.83
1 11 /16
3
1.96
1 1 /2
4
3.66
1 11 /16
5
8.60
2 5 /8
6
10.73
2
14
A dapter Flush •
APPROX. DIM. B
NOM. SIZE NET WT. /LBS. INCHES
11
3/4 0.03 19 /32
14
H ose Adapter /
APPROX. DIM. A
NOM. SIZE NET WT. /LBS. INCHES
0.09
NOTE: Fits 1 1z," s /e" and 3 /4" Garden Hose.
M
604 -2
Fitting Adapter Ftg x M - Wrot
NOM. SIZE
1/8
APPRIVA.
NET WT./LBS.
0.02
1
INCHES
1 1 /8
3/8
0.04
1 1 /4
112
0.09
1 15 /32
112 x 3/4
0.16
1 13 /16
112 x 3/8
0.04
1 11 /32
3/4
0.17
1 15 /16
1
0.25
2 1 /4
704 -2
Fitting Adapter Ftg x M - Cast
2112 1.55 3 3 /8
3 2.21 3 23 /32
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1574.295.3221 • FAX: +1.574195.3455
Aht'&*A.
11M.
NOM. SIZE
NET VVT./L13S.
INCHES
3/4 x 1
0.27
1 31 /32
3/4 x 112
0.12
1 23 /32
1 x 3/4
0.24
1 15 /16
11/4
0.43
2 27 /32
1112
0.54
2 13 /32
2
0.89
2 3 /4
2112 1.55 3 3 /8
3 2.21 3 23 /32
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1574.295.3221 • FAX: +1.574195.3455
ADAPTERS continued
r
6 k
704 -2 -H
Hose Adapter Ftg x Hose -Cast
APPR 1
1
3/4 F x 112 H 0.16 1
NOTE: Fits' /i" s /e" and 3 /4" Garden Hose,
AIR CHAMBERS
I •
Cham ber Air 1
APPROX. DIM.A DIM. L
N07M SNOM. SIZE NET WT. /LBS. INCHES INCHES
112 x • 1
112 x 12 1
112 x 14 0.78 1 14
3/4 x 12 0.40 1 12
620 -L
Air Chamber or Stub -Out
Ftg - Wrot
As Air Chamber, just solder one joint. When used
as Stub -Out, simply pressure test system then cut
off stub-out (save piece for future use) and install
valve or fixture.
APPRUX. DIM. L
NOM. SIZE NET WT. /LBS. INCHES
112 x • 1
1/2x8 0.19 8
112 x 10 0.24 10
1/2x12 0.28 12
3/4 x 12 0.46 12
BULKHEAD
FITTINGS
_�
VA-
750
Bulkhead Fitting C x C - Cast
APPROX DIM A 1
N SIZE NET VVT./LBS. INCHES INCHES
112 0.48 1'/4 1
3/4 0.77 1 1
1 1.30 1 1
1112 2.87 1 2
2 3.82 2 2
r
.0 ■IllliliP
75 0 - 3
Bulkhead
APPROX. DIM. A DIM. B
NOM. SIZE NET WT. /LBS. INCHES INCHES
0 .48 115/16 1
1
1 1.43 2 1
f =�Illll�lllualll
I �illlll�lllllllilll
75 0 - 4
Bulkhead
APPROX. DIM. A DIM. B
NOM. SIZE NET WT. /LBS. INCHES INCHES
0.40 1 1
1
BUSHINGS
..........
L
618
Flush Bushing Ftg x C - Wrot
N SIZE
1/4 x 1/8
'• •1
NET VVT./LBS.
0.01
1 .
INCHES
1 /16
3/8 x 1/4
0.01
'/16
112 x 3/8
0.02
3 /32
112 x 1/4
0.04
1 /4
5/8 x 112
0.03
'/16
3/4 x 5/8
0.22
3 /16
3/4 x 112
0.08
3 /32
3/4 x 3/8
0.11
'/16
1 x 3/4
0.12
'/8
1 x 112
0.22
15 /32
11/4 x 1
0.17
3 /32
1112 x 1 1/4
0.22
5 /32
2 x 1112
0.66
'/8
I ro B
618 -3
Flush Bushing Ftg x F - Wrot
APPR 1
N SIZE NET Wr./LBS. INCHES
112 x 1/8 0.03 9 /16
112 x 1/4 0.03 9 /16
1 x 112 0.13 31 /32
11/4 x 3/4 0.18 1
1112 x 1 0.25 1
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574195.3221 • FAX: +1.574.295.3455
617
Tube Cap C - Wrot
APP
NOM. SIZE NET WT 11 Bs
1/8 0.01 '/32
1/4 0.01 3 /32
3/8 0.01 3 /32
112 0.02 3 /32
5/8 0.03 1 /8
3/4 0.04 '/8
1 0.07 5 /32
11/4 0.10 3 /32
1 112 0.16 1 /8
2 0.27 5 /32
2112 0.50 7 /32
3 0.78 7 /32
4 1.66 1 /4
I -N
717
Tube Cap C - Cast
APPROX. DIM. N
NOM. SIZE NET WTABS. INCHES
5 5.48 The
6 9.07 17 /32
-►I A (+-
717-D
Drain Cap - Cast
APP
NOM. SIZE NET WTABS. INCHES
112 0.06 21 /32
Consult price sheet for Made to Order items and
for minimum order quantities.
COUPLINGS
A �'1 t•
600
Reducing Coupling C x C - Wrot
APP
NOM. SIZE NET VVT.ILBS. INCHES
1/8 x 3/16 O.D. 0.01 5 /32
5/16 O.D. x 1/8 0.01 3 /16
1/4 x 5/16 O.D. 0.01 3 /16
1/4 x 1/8 0.01 3 /16
3/8 x 1/4 0.02 3 /16
3/8 x 5/16 O.D. 0.01 '/4
3/8 x 1/8 0.01 1 /4
112 x 3/8 0.03 3 /16
112 x 1/4 0.02 1 /4
112 x 1/8 0.03 "/32
5/8 x 112 0.05 3 /16
5/8 x 3/8 0.04 11 /32
5/8 x 1/4 0.03 13 /32
3/4 x 5/8 0.07 3 /16
3/4 x 112 0.06 9 /32
3/4 x 3/8 0.06 3 /8
3/4 x 1/4 0.05 11 /32
1 x 3/4 0.11 11 /32
1 x 5/8 0.09 3 /8
1 x 112 0.10 11 /32
1 x 3/8 0.10 13 /32
1 1/4 x 1 0.16 5 /16
1 1/4 x 3/4 0.18 17 /32
1 1/4 x 5/8 0.18 5 /8
1 1/4 x 112 0.14 7 /16
1 112 x 11/4 0.23 5 /16
1 112 x 1 0.22 9 /16
1 112 x 3/4 0.20 3 /8
1 112 x 112 0.19 '/2
2 x 1112 0.41 9 /16
2 x 11/4 0.35 11 /16
2 x 1 0.37 7 /16
2 x 3/4 0.34 17 /32
2 x 112 0.35 23 /32
21 12 x 2 0.59 9 /16
21/2 x 1 112 0.65 11 /16
21 12 x 1 1/4 0.65 13 /16
21 12 x 1 0.73 29 /32
Continues...
NOM. SIZE NET WT./LBS INCHES
3 x 21/2 0.98 '12
3 x 2 1.06 15 /16
3 x 1 112 0.92 1'/32
31/2 x 3 1.52 1 12
4 x 31 12 2.12 19 /32
4 x 3 1.92 27 /32
4x21/2 1.77 1
4 x 2 1.92 1
5 x 4 3.50 3
5 x 3 3.18 1
5 x 21 12 3.50 13 /16
5 x 2 3.09 2
6 x 5 5.70 1
6 x 4 5.24 1
6 x 3 5.04 2
6 x 21/2 5.13 2'/4
6 x 2 4.89 2
8 x 6 13.06 1
8 x 4 12.22 2
8 x 3 11.79 3
8 x 21 12 12.64 3
A* - : ]j
�-A
600 -RS
Coupling with Rolled Tube Stop
CXC - Wrot
APP
NOM. SIZE NET WT./LBS. INCHES
1/8 OR D. 0.01 1 /16
3/16 0. D. 0.01 3 /32
1/8 0.01 1 /16
5/16 0. D. 0.01 3 /32
1/4 0.01 '/16
3/8 0.01 3 /32
112 0.03 3 /32
5/8 0.04 3 /32
3/4 0.06 3 /32
7/8 0.09 3 /32
1 0.11 3 /32
11/4 0.16 1 /8
11/2 0.23 '/8
2 0.41 1 /8
2112 0.65 1 /8
3 0.93 '/8
31/2 1.45 5 /32
4 1.93 7 /32
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1574.295.3221 • FAX: +1.574.295.3455
COUPL INGS continued
T F -
600 -DS
Coupling with Dimpled Tube Stop
CxC - Wrot
NOM. SIZE
3/16 O.D.
APP Rilk
NET VVT./LBS.
0.01
DIF11 ,
INCHES
3 /32
1/8
0.01
' /16
5/16 0. D.
0.01
3 /32
1/4
0.01
' /16
3/8
0.01
3 /32
112
0.03
3 /32
5/8
0.04
3 /32
3/4
0.06
3 /32
7/8
0.09
3 /32
1
0.11
3 /32
11/4
0.16
1 /8
11/2
0.23
1 /8
2
0.41
1 /8
2112
0.65
1 /8
3
0.93
'/8
31/2
1.45
5 /32
4
1.93
1 /32
5
3.53
7 /32
6
5.63
1 /32
8
14.12
15 /32
601
Coupling without Stop
CxC - Wrot
APPROX. DIM. B
1 NOM. SIZE NET WT./LBS. INCHES
1/4 0.01 11 /16
3/8 0.01 27 /32
112 0.03 1
5/8 0.04 1
3/4 0.06 1
1 0.11 1
11/4 0.16 2
1 112 0.23 2
2 0.41 2
2112 0.64 2
3 0.86 3
31/2 1.40 3
4 1.84 4
5 3.50 5
6 5.60 6
8 13.68 8
16 D
A-►I
701
Reducing Coupling C x C - Cast
APPROX. DIM. A
NOM. SIZE NET WT./LBS. INCHES
3 x 11/4 1.35 23 /32
3 x 1 1.64 27 /32
701 -D
Drain Coupling C x C - Cast
APPROX. DIM. A
NOM. SIZE NET WT./LBS. INCHES
112 0.08 '/4
3/4 0.14 1 /4
1 0.22 '/4
A - +�
702
Eccentric Coupling C x C - Cast
i
NOM. SIZE NET WT./LBS. INCHES
3/4 x 112 0.10 "/32
1 x 3/4 0.18 'A
11/4 x 1 0.25 'A
11/4 x 3/4 0.24 9 /32
0
G
724 -5 -A
Hy -Set Hanger Coupling
C - Cast
APP
NOM. SIZE NETVVT./LBS. INCHES INCHES
112 0.05 1 23 /32
3/4 0.09 1 /8 27 /32
1 0.13 1 /8 1
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574295.3221 • FAX: +1.574.295.3455
COUPLINGS continued
J
736
Cross -Over Coupling
CXC - Cast
APPROX. 1
NOM. SIZE NET WT./LBS. INCHES
112 0.27 1 7 /16
3/4 0.60 1 29 /32
Consult price sheet for Made to Order items and
for minimum order quantities.
CROSSES
735
CrossCxCxCxC - Cast
NOM. SIZE
3/8
'1'
NET WI/LBS.
0.09
1
INCHES
3 /8
112
0.15
7 /16
3/4
0.30
9 /16
1
0.54
23 /32
11/4
0.78
7 /8
1 112
1.05
1
2
2.00
1 1 /4
2112
2.96
1 1 12
ELBOWS
E ' to ' qL5
4 Elbow 1
APPROX. DIM. C DIM. D
NOM. SIZE NET WT. /LBS. INCHES INCHES
11
1/4
0.02
9 /32
9 /32
3/8
0.03
3 /16
3 /16
112
0.04
9 /32
9 /32
5/8
0,09
15 /32
75 /32
3/4
0.10
11 /32
11 132
7/8
0.20
11 /16
11 /16
1
0.16
3 /8
3 /8
1 1/4
0.25
17 /32
17 /32
11/2
0.35
19 /32
19 /32
2
0.65
25 /32
25 /32
2 112
1.07
29 /32
29 /32
3
1.58
1 1 /8
1 1 /8
4
3.35
1 7 /16
1 7 /16
5
11.05
1 9 /16
1 9 /16
6
16.95
2
2
8
23.00
2 9 132
2 9 /32
AAL
606 -2
45° Fitting Elbow Ftg x C - Wrot
1
1/4
A"A41A.
0.02
DIFTI.
9 /16
1
1 /4
112
0.04
3 /4
7 /32
5/8
0.08
1 1 /8
13 /32
3/4
0.10
1 1 /16
5 /16
1
0.16
1 7 /32
75 /32
11/4
0.25
1 19 /32
17 /32
1 112
0.35
1 25 /32
19 /32
2
0.65
2 3 /16
25 /32
2112
1.07
2 3 /16
29 /32
3
1. 55
2 19 /32
1 5 /32
NIBCO INC. WORLD HEADQUARTERS ' 1516 MIDDLEBURY ST. ^ IN 46516 -4740 • USA ' PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 ' FAX: +1.574.295.3455
ELBOWS continued
a�
0.
45' Fitting El
APPROX. DIM. B DIM. C
NOM. SIZE NET WT. /LBS. INCHES INCHES
i 3
607
90° Elbow - Close Rough
CXC - Wrot
NOM. SIZE NETWT./LBS.
1/8
,.
0.01
„
INCHES
13 /32
, , ,
INCHES
13 /32
1/4
0.02
9 /32
9 /32
3/8
0.03
'12
'12
112
0.04
3 /8
3 /8
112 x 3/8
0.04
9 /16
21 /32
3/4
0.10
17 /32
17 /32
3/4 x 5/8
0.12
29 /32
7 /8
3/4 x 112
0.10
17 /32
'A
1
0.21
23 /32
23 /32
1 x 3/4
0.16
23 /32
5 /8
11/4
0.31
1
1
1 1/4 x 1
0.31
1
1' 5 /32
1 112
0.46
1
1
1 112 x 1 1/4
0.35
1
1
2
0.84
1
1
2 x 1 112
0.58
1
1
21 12
1.41
1
1
3
2.07
2
2
31 12
2.94
2
2
4
4.23
2
2
5
7.74
2
2
6
10.95
3
3
8
29.50
4
4
707
90° Elbow - Close Rough
CXC - Cast
APPROX. DIM. C DIM. D
NOM. SIZE NETWT./LBS. INCHES INCHES
11/4 x 1 0.42 1 1
11/4 x 3/4 0.34 9 /16 13 /16
11/4 x 112
0.28
75 /32
2 '/32
1112 x 1
0.54
11 /16
1
1 112 x 3/4
0.42
19 /32
31 /32
1 112 x 112
0.40
5 /8
29 /32
2 x 11/4
0.86
7 /8
1
2 x 1
0.78
3 /4
1
2 x 3/4
0.69
5 /8
1
21 12 x 2
2.16
1
19 /32
3 x 21/2
2.26
1
1
3 x 2
2.68
1
1
4 x 3
5.18
1
2
607 -1
,...,.
NET WT./LBS.
0.01
90° Elbow -
INCHES
13 /32
Intermediate Radius C x C
- Wrot
AP i
NOM. SIZE NET WT./LBS. INCHES
INCHES
5/16 0. D.
112 0.06 19 /32
19 /32
5/8 0.09 7 /8
7 /8
3/4 0.14 13 /16
3 /16
1 0.24 1
1
607 -LT
90° Elbow - Long Radius
CXC - Wrot
NOM. SIZE
3/16 0. D.
,...,.
NET WT./LBS.
0.01
,
INCHES
13 /32
INCHES
13 /32
1/8
0.01
13 /32
13 /32
5/16 0. D.
0.02
9 /16
9 /16
1/4
0.02
17 /32
17 /32
1/4 x 1/8
0.01
79 /32
1 12
3/8
0.04
23 /32
23 /32
112
0.08
'/8
7 /8
112 x 3/8
0.06
13 /16
13 /16
112 x 1/4
0.03
25 /32
21 /32
5/8
0.10
1
1
5/8 x 112
0.09
1 /16
1
3/4
0.16
1
1
3/4 x 5/8
0.13
1
1
3/4 x 112
0.10
1
1 /16
7/8
0.28
1
1
1
0.28
1'/16
1
1 x 3/4
0.20
1' /4
1
1 x 5/8
0.15
1
1
1 1/4
0.42
1
1
1 1/4 x 1
0.33
1
1
11/2
0.66
2'/4
2
2
1.23
2
2
2112
1.96
3
3
3
2.93
4
4
4
5.95
5
5'/4
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
607 -2
90° Fitting Elbow - Close Rough
Ftg x C - Wrot
NOM. SIZE
1/4
AiLIPROA.
NETWT/LBS.
0.02
INCHES
3 /4
INCHES
3 /8
3/8
0.03
15 /16
'12
112
0.04
31 /32
3 /8
5/8
0.07
1
17 /32
3/4
0.10
1 "/32
17 /32
1
0.20
1 3 /4
27 /32
11/4
0.33
2 1 /8
1
1 112
0.46
2
1
2
0.84
2
1
21 12
1.39
3
1
3
2.10
3 13 /16
2
4
4.00
4 3 /4
2
L
•1
•1' Fitting Elbow
Intermediate Radius
APPROX. DIM. B DIM. C
NOM. SIZE NET WT. /LBS. INCHES INCHES
10
5/8 0.09 1 9 /16 7 /8
3/4 0.14 1 13 /16
1 0.24 2 1 1 /16
Consult price sheet for Made to Order items and
for minimum order quantities.
607 -2 -LT
90° Fitting Elbow - Long Radius
Ftg x C - Wrot
NOM. SIZE NETVV'T.ILBS.
1/8
WYLA41A.
0.01
DIM.
INCHES
73 /32
,
INCHES
'12
1/4
0.02
1
3 /4
3/8
0.05
1'/8
7 /8
112
0.08
1 9 /16
1
112 x 3/8
0.06
1 5 /16
13 /16
112 x 1/4
0.03
1 7 /4
5 /8
5/8
0.10
1
1
3/4
0.16
1 15 /16
1
1
0.31
2'12
1
11/4
0.43
2
1
11/2
0.66
2
2 1 /4
1 112 x 11/4
0.50
3
2
2
1.27
4 "/32
2
2112
2.16
5
3 11 /16
3
3.10
5 3 /4
4 1 /32
L L
607 -2 -2
90° Fitting Elbow -Close Rough
Ftg x Ftg - Wrot
APPROX.
NOM. SIZE NET WT./LBS. INCHES
112 0.04 1 1 /16
3/4 0.12 1
3 2.12 3
1112 0.46 2
2 0.82 2
1 0.20 1
11/4 0.33 2'/8
607- 2 -2 -LT
90° Fitting Elbow - Long Radius
Ftg x Ftg - Wrot
NOM. SIZE
1/4
AstiRktA.
NET VVT./LBS.
0.02
.
INCHES
27 /32
3/8
0.04
1'/8
112
0.08
1
5/8
0.10
1 "/16
3/4
0.16
1 15 /16
1
0.31
2'12
11/4
0.43
2
11/2
0.65
3 7 /16
2
1.25
4
1
•1• Fitting Elbow
APPROX. DIM. B DIM. E
NOM. SIZE NET WT. /LBS. INCHES INCHES
1
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
ELBOWS continued
ELBOWS continued
707 -3
90° Elbow C x F - Cast
1/4
0.06
13 /32
9 /16
3/8
0.09
1 /16
11 /16
3/8 x 112
0.13
9 /16
13 /16
112
0.12
1 /16
13 /16
112 x 3/4
0.18
11 /16
15 /16
112 x 3/8
0.09
1 12
13 /16
112 x 1/4
0.10
3 /8
23 /32
3/4
0.18
21 /32
15 /16
3/4 x 1
0.35
13 /16
1
3/4 x 112
0.20
9 /16
15 /16
1
0.43
25 /32
1
1 x 3/4
0.35
11 /16
1
1 x 112
0.26
9 /16
1
11/4
0.67
1
1
1 1/4 x 3/4
0.47
9 /16
1
11/2
0.89
1
1
2
1.46
1
1
6#0 C L Al -Et
Ina
7 07- 3 -5
• 1' 1 1/ Elbo
NOM. APPROX. DIM. A DIM. C E
3/8
0.12
11 /32
7 /16
11 /16
3/8 x 112
0.18
11 /32
9 /16
13 /16
1/2
0.15
13 /32
9 /16
7 /8
112 x 3/8
0.17
3 /8
1 /2
13 /16
3/4
0.28
17 /32
21 /32
15 /16
3/4 x 112
0.24
11 /32
9 /16
15 /16
1
0.49
5 /8
25 /32
1
1
1
'1' El
APPROX. DIM. C DIM. E
NOM. SIZE NET WT. /LBS. INCHES INCHES
1
707 -3 -6
90° Union Elbow C x F - Cast
112 0.31 1 7 /8
3/4 0.49 1 1
1 0.79 1 1
707 -4
90° Elbow C x M - Cast
3/8
0.08
5 /16
7 /8
1/2
0.12
7 /16
1
112 x 3/4
0.18
9 /16
1
112 x 3/8
0.10
5 /16
15 /16
3/4
0.21
9 /16
1
3/4 x 1
0.33
21 /32
1
3/4 x 112
0.18
7 /16
1
1
0.43
23 /32
1
11/4
0.58
7 /8
1
11/2
0.81
1
1
2
1.38
1
2
z �
r mu n
707 -4 -6
90° Union Elbow C x M - Cast
3/8
0.21
1
1
112
0.30
1
1
3/4
0.49
1
1
1
0.72
1
1
11/4
1.16
1
1
46 j j ,
1
• 1' Dr op Elbo
APPROX. DIM. A DIM. C
NOM. SIZE NET WT. /LBS. INCHES INCHES
1
1
1
•1' 11 C a st
NOM. APPROX. DIM. A DIM. C DIM. D
SIZE NETWTJLBS. INCHES INCHES INCHES
1
3/4 0.21 1 9 /16 9 /16
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
ELBOWS continued
FITTING REDUCERS
707 -6
90° Union Elbow C x C - Cast
3/8
0.17
31 /32
5 /16
112
0.24
1
7 /16
3/4
0.39
1 "/32
9 /16
1
0.64
1
23 /32
11/4
1.07
1
23 /32
I
C
708
90° Flanged Sink Elbow
C x F - Cast
A --«
F
112 0.20 1 /8 9 /16 1
D _
764
90° Double Elbow
CxCxC - Cast
1 x 3/4 x 3/4 0.33 3 /4 21 /32
Consult price sheet for Made to Order items and
for minimum order quantities.
600 -2
Fitting Reducer Ftg x C - Wrot
NOM. SIZE
1/4 x 1/8
Ae MPA .
NET VVT.1LBS.
0.01
D 117
INCHES
15 /32
3/8 x 1/4
0.01
19 /32
3/8 x 1/8
0.01
25 /32
112 x 3/8
0.03
11 /16
112 x 1/4
0.02
25 /32
5/8 x 112
0.04
1 /8
5/8 x 3/8
0.04
31 /32
5/8 x 1/4
0.03
1'/32
3/4 x 5/8
0.06
31 132
3/4 x 112
0.06
1' /8
3/4 x 3/8
0.05
1' /8
3/4 x 1/4
0.05
1
1 x 3/4
0.10
1
1 x 5/8
0.09
1
1 x 112
0.09
1'/4
1 x 3/8
0.08
1
1 1/4 x 1
0.15
1
1 1/4 x 3/4
0.16
1
1 1/4 x 112
0.13
1
1 112 x 11/4
0.23
1
1 112 x 1
0.21
1
1 112 x 3/4
0.20
1
1 112 x 112
0.16
1
2 x 1112
0.40
1
2 x 11/4
0.34
2
2 x 1
0.35
1
2 x 3/4
0.35
1
2 x 112
0.34
1
21/2 x 2
0.65
1
21 12 x 1 112
0.65
2
21/2 x 1 1/4
0.60
2
21 12 x 1
0.78
2
3 x 21/2
1.03
2
3 x 2
0.99
2
3 x 1 112
0.81
2
3 x 1 1/4
1.29
3
31 12 x 3
1.48
2 "/32
- 6x2
4.51
Continues...
4 x 31 12
2.09
2 /a
4 x 3
2.00
3
4 x 21/2
1.56
3
4 x 2
1.76
3 13 /32
5 x 4
3.30
3
5 x 3
2.97
4
5 x 21 12
3.30
4 "/32
5 x 2
2.88
4 "/16
6 x 5
5.56
4
6 x 4
5.09
4
6 x 3
4.67
5
6 x 21 12
4.47
5 1 '/32
- 6x2
4.51
5
- 8x6
12.33
5 15 /32
8 x 5
10.35
5
- 8x4
11.10
6
8 x 3
10.63
6
8 x 21 12
11.41
7
8 x 2
10.86
7
FLANGES -
CLASS 125
7 /16
� �i I -
F
C ompanion F. 1'
NOM. APPROX. DIM. B DIM. F DIM. G r
112
0.55
'/8
3'/2
3 /16
2
3/4
0.71
'/8
3
3 /16
2
1
1.26
1 /8
4
1 /4
3
11/4
1.42
1 /8
4
1 /4
3
11/2
1.82
1 /8
5
5 /16
3
2
2.76
1 /8
6
3 /8
4
21/2
4.29
'/8
7
3 /8
5
3
5.26
1 /8
7
7 /16
6
4
7.60
1 /8
9
7 /16
7'/2
5
9.04
1 /8
10
7 /16
8
6
12.68
1 /8
11
1 12
9
NOTE: Dim. B = Tube Stop to Flange Face
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. ^ ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
FLANGES -
CLASS 150
771
Companion Flange C -
NOM. APPROX. DIM. B DIM. F
SIZE NETVVTJLBS. INCHES INCHES
3/4 1.15 '/6 3
Cast
DIM. G
INCHES
11 /32
DIM. W
INCHES
2
1
1.59
1 /8
4
3 /8
3
11/4
1.91
'/8
4
13 /32
3'/2
11/2
2.59
1 /8
5
7 /16
3
2
4.10
1 /8
6
1 12
4
2112
6.22
1 /6
7
9 /16
5'/2
3
8.03
1 /8
7'/2
5 /8
6
4
11.85
1 /8
9
11 /16
7
5
15.69
1 /8
10
3 /4
8'/2
6
20.32
1 /8
11
13 /16
9
NOTE: Dim. B = Tube Stop to Flange Face
CD
w
E
775
Threaded Companion Flange
F - Cast
2 4.31 1
2112 6.30 1' /8
PLUGS
-- ��H
616
Fitted Plug Ftg - Wrot
APPROX. DIM. A
NOM. SIZE NET VVT.1LBS. INCHES
3/8 0.016 '/16
112 0.02 3 /32
3/4 0.24 '/6
638
Return Bend C x C - Wrot
1/8
0.02
21 /32
1
1/4
0.04
21 /32
1
3/8
0.08
1'/32
1
112
0.13
1
2
3/4
0.26
1
2'12
1
0.44
2
3
11/4
0.70
2
4
11/2
1.04
3
4'/2
2
1.92
3
5
\iii
STRAPS
623
Copper Hanger Strap
APP
SIZE NET VVT./LBS.
3/4" Wide x 25 Ft. Roll 1.93
dftf
624
Tube Strap
APP
NOM. SIZE NET WT./LBS.
1/8 0.01
1/4 0.01
3/8 0.01
112 0.01
5/8 0.02
3/4 0.02
1 0.02
11/4 0.03
1 112 0.03
2 0.04
TEES
C
D- E
705
Baseboard Tee C x F x C- Cast
6 4 112 x 1/8 x 3/4 0.15 1 /16 9 /16 "/16
7 5 E 1 /2 x 1/8 x 112 0.11 1 /16 7 /16 9 /16
3 7.13 1 7 6
4 10.20 1 9 7
7 39 3/4 x 1/8 x 1 0.29 5 /8 3 A 13 /16
Return Bend - Closed 3/4 x 1/8 x 3/4 0.19 9 /16 9 /16 11 /16
C x C Cast 1 X 1 /8 x l 0.32 23 /32 23 /32 3 /4
APPROX. DIM. E DIM. J 11/4 x 1/8 x 11/4 0.51 7 /6 1 /8 15 /16
NOM. SIZE NET WT./LBS. INCHES INCHES
3/4 0.29 1 1
Consult price sheet for Made to Order items and
for minimum order quantities.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Sa
705 -D
VentElbowCxC - Cast
112 0.10 7 /16 7 /16 25 /32
3/4 0.20 9 /16 9 /16 29 /32
1 0.31 23 /32 23 /32 1
710 -3
TeeFxFxC - Cast
112 0.20 9 /16 7 A 7 /8
3/4 0.37 "/16 1 1
3/4 x 3/4 x 112 0.31 11 /16 31 /32 31 /32
3/4 x 112 x 3/4 0.29 11 /16 1 15 /16
3/4 x 112 x 112 0.27 11 /16 31 /32 7 /8
C
5�
710 -3 -4
Tee MxFxC -Cast
3/4 0.34 1 '/16 1 1
3/4 x 3/4 x 112 0.33 11 /16 1 31 /32
Consult price sheet for Made to Order items and
for minimum order quantities.
611
TeeCxCxC - Wrot
3/160D
0.01
7 /32
7 /32
7 /32
1/8
0.02
'/4
1 /4
7 /32
1/8 x 1/8 x 1/4
0.02
13 /32
13 /32
'/4
1/8 x 1/8 x 3/160D
0.01
1 /4
1 /4
5 /16
1/8 x 3/160.D x 1/8
0,01
'/4
11 /32
7 /32
5/160D
0.02
3 /8
3 /8
5 /16
5 /16oD x 5 /16oD x 1/4 0.02
3 /8
3 /8
'/4
5/160D x 5 /16oD x 1/8 0.02
3 /8
3 /8
13 /32
5/160D x 1/8 x 5/160D 0.02
3 /8
13 /32
5 /16
5/160D. x 1/8 x 1/8
0.02
3 /8
13 /32
13 /32
1/4
0.02
5 /16
5 /16
1 /4
1/4 x 1/4 x 112
0.06
19 /32
19 /32
3 /8
1/4 x 1/4 x 3/8
0.04
17 /32
17 /32
1 '/32
1/4 x 1/4 x 5/160D.
0.02
5 /16
5 /16
5 /16
1/4 x 1/4 x 1/8
0.02
5 /16
5 /16
13 /32
1/4 x 1/4 x 3 /16oD
0.02
5 /16
5 /16
7 /16
1/4 x 5 /16o.D.x 1/4
0.02
5 /16
3 /8
1 /4
1/4 x 1/8 x 1/4
0.02
5 /16
13 /32
'/4
1/4 x 1/8 x 1/8
0.02
5 /16
13 /32
3 /8
3/8
0.04
" /32
11 /32
11 /32
3/8 x 3/8 x 112
0.07
17 /32
17 /32
3 /8
3/8 x 3/8 x 1/4
0.04
11 /32
11 /32
15 /32
3/8 x 3/8 x 5/160D
0.04
"/32
"/32
11 /32
3/8 x 3/8 x 1/8
0.04
11 /32
" /32
11 /32
3/8 x 1/4 x 3/8
0.04
17 /32
17 /32
" /32
3/8 x 1/4 x 1/4
0.04
11 /32
17 /32
15 /32
3/8 x 1/4 x 1/8
0.04
"/32
17 /32
9 /16
3/8 x 1/8 x 3/8
0.04
11 /32
79 /32
11 /32
3/8 x 1/8 x 1/8
0.04
11 /32
19 /32
19 /32
112
0.06
11 /32
11 /32
11 /32
112 x 112 x 1
0.29
1
1
21 /32
112 x 112 x 3/4
0.12
17 /32
17 /32
11 /32
112 x 112 x 5/8
0.11
5 /8
5 /8
7 /16
112 x 112 x 3/8
0.07
5 /16
5 /16
13 /32
112 x 112 x 1/4
0.06
5 /16
5 /16
9 /16
112 x 3/8 x 112
0.07
7 /16
17 /32
3 /8
112 x 3/8 x 3/8
0.06
5 /16
11 /32
13 /32
112 x 3/8 x 1/4
0.06
5 /16
17 /32
17 /32
112 x 1/4 x 3/8
0.06
5 /16
5 /8
9 /16
5/8 x 5/8 x 1/4
0.09
7 /16
Continues...
NOTE: Tee sizes are read Run x Run x Outlet.
5/8
0.12
7 /16
7 /16
7 /16
5/8 x 5/8 x 3/4
0.15
23 /32
23 /32
'12
5/8 x 5/8 x 112
0.11
7 /16
7 /16
13 /32
5/8 x 5/8 x 3/8
0.09
7 /16
7 /16
5 /8
5/8 x 5/8 x 1/4
0.09
7 /16
7 /16
3 /4
5/8 x 112 x 5/8
0.10
7 /16
5 /8
7 /16
5/8 x 112 x 112
0.09
7 /16
19 /32
13 /32
5/8 x 3/8 x 5/8
0.10
7 /16
3 /4
7 /16
5/8 x 3/8 x 3/8
0.09
7 /16
3 /4
5 /8
3/4
0.15
'12
'12
'12
3/4 x 3/4 x 1
0.22
23 /32
23 /32
1 12
3/4 x 3/4 x 5/8
0.16
17 /32
17 /32
11 /16
3/4 x 3/4 x 112
0.12
7 /16
7 /16
77 /32
3/4 x 3/4 x 3/8
0.12
7 /16
7 /16
21 /32
3/4 x 3/4 x 1/4
0.12
13 /32
13 /32
23 /32
3/4 x 3/4 x 1/8
0.12
7 /16
7 /16
13 /16
3/4 x 5/8 x 3/4
0.15
17 /32
11 /16
1 /2
3/4 x 5/8 x 5/8
0.15
17 /32
23 /32
11 /16
3/4 x 112 x 3/4
0.15
17 /32
25 /32
1 12
3/4 x 112 x 112
0.12
13 /32
19 /32
1 12
3/4 x 112 x 3/8
0.12
7 /16
21 /32
21 /32
3/4 x 3/8 x 3/4
0.15
17 /32
17 /32
1 12
3/4 x 3/8 x 112
0.12
7 /16
23 /32
17 /32
3/4 x 3/8 x 3/8
0.12
7 /16
23 /32
21 /32
7/8
0.31
23 /32
23 /32
23 /32
1
0.30
11 /16
11 /16
2 '/32
1 x 1 x 1112
0.60
1 1 31 /32
1 x 1 x 11/4
0.42
1
1
29 /32
1 x 1 x 3/4
0.27
9 /16
9 /16
21 /32
1 x 1 x 5/8
0.26
9 /16
9 /16
7 /8
1 X 1 X 112
0.23
75 /32
15 /32
23 /32
1 X 1 X 3/8
0.23
15 /32
15 /32
29 /32
1 x 1 x 1/4
0.23
'
15 /32
1
1 x 3/4 x 1
0.29
11 /16
7 /8
21 /32
1 x 3/4 x 3/4
0.26
9 /16
23 /32
3 /4
1 x 3/4 x 112
0.22
15 /32
21 /32
23 /32
Continues
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
TEES continued
TEES continued
I
lik 4L L-i-T
G
C F
611
Tee C x C x C- Wrot continued
APPROX. DIMENSIONS
NET WT. INCHES
NOM. SIZE LBS. C F G
I x 112 x 1 0.29 11 /16 1 2 '/32
1 x 112 x 3/4
0.27
9 /16
13 /16
3 /4
1 x 112 x 112
0.22
15 /32
25 /32
23 /32
11/4
0.43
13 /16
3 /16
13 /16
1 1/4 x 1 1/4 x 2
1.13
1 30 /32 1 30 /32 1 3 /32
1 1/4 x 1 1/4 x 1 112
0.60
1 3 /16 1 3 /16
29 /32
1 1/4 x 1 1/4 x 1
0.45
25 /32
25 /32
29 /32
1 1/4 x 1 1/4 x 3/4
0.37
21 /32
21 /32
3 /4
1 1/4 x 1 1/4 x 112
0.30
'12
'12
25 /32
1 1/4 x 1 1/4 x 3/8
0.34
23 /32
23 /32
29 /32
1 1/4 x 1 x 11/4
0.43
13 /16
1 1 /32
13 /16
1 1/4 x 1 x 1
0.47
25 /32
7 A
29 /32
1 1/4 x 1 x 3/4
0.35
21 /32
25 /32
7 /8
1 1/4 x 1 x 112
0.30
1 12
5 /8
29 /32
1 1/4 x 3/4 x 1 1/4
0.42
13 /16
1 1 /8
13 /16
1 1/4 x 3/4 x 1
0.45
25 /32
1 1 /32
29 /32
11/4 x 3/4 x 3/4
0.37
21 /32
75 /16
7 /8
11/4 x 3/4 x 112
0.30
1 12
3 /4
29 /32
11/4 x 112 x 11/4
0.41
13 /16
1 7 /32
13 /16
1112
0.61
31 /32
31 /32
29 /32
1112 x1 1/2x2
1.11
1 25 /32
1 25 /32
1 3 /32
1 112 x 1 112 x 11/4
0.62
29 /32
29 /32
1'/16
1 112 x 1 112 x 1
0.55
11 /16
11 /16
7 /8
1 112 x 1 112 x 3/4
0.45
11 /16
11 /16
1'/32
1 112 x 1 112 x 112
0.40
1 12
1 12
1'/32
1 112 x 1 1/4 x 1112
0.62
1 1 /32
1 3 /16
29 /32
1 112 x 1 1/4 x 11/4
0.62
31 /32
1 3 /32
31 /32
1 112 x 1 1/4 x 1
0.51
25 /32
1
1 1 /32
1 112 x 1 1/4 x 3/4
0.49
11 /16
13 /16
1'/32
1 112 x 1 1/4 x 112
0.41
'12
25 /32
1 1 /32
1 112 x 1 x 1112
0.59
1'/32 1 11 /32 29 /32
1 112 x l x 11/4
0.63
29 /32
1'/8
1'/16
1 112 x 1 x 1
0.54
25 /32
1 1 /16 1'/32
1 112 x 1 x 3/4
0.44
"h6
31 /32
15 /16
1 112 x 1 x 112
0.39
1 /2
25 /32
1'/32
1112 x 3/4 x 1112
0.62
1 1 /32 1 7 /16 1 1 /16
1112 x 3/4 x 11/4
0.58
29 /32 1 " / 32 1 1 /16
1112 x 3/4 x 1
0.54
25 /32
1 1 /4
1 1 /32
1112 x 3/4 x 3/4 0.47 11 /16 1 3 /32 29 /32
1112 x 3/4 x 112 0.39 '12 29 /32 31 /32
1112 x 112 x 1112 0.62 1 1 /32 1 13 /32 31 /32
Continues...
2
1.30
1 9 /32 1 9 /32 1 1 /32
2 x 2 x 21/2
2.34
2 2 1 21 /32
2 x 2 x 1112
1.17
1 1 1 23 /32
2 x 2 x 1 1/4
1.12
9 /32 9 /32 1 7 /8
2 x 2 x 1
0.90
27 /32 27 /32 1
2x 2 x 3/4
0.88
19 /32 19 /32 1
2 x 2 x 1/2
1.17
1 1 /4 1'/4 2
2 X 1 112 x 2
1.16
1 9 /32 1 7 /8 1 11 /32
2 x 1 112 x 1 112
1.15
1 1 3 /4 1 23 /32
2 x 1 112 x 1 1/4
1.15
7 /32 1 3 /4 1 "/32
2 x 1 112 x 3/4
0.83
21 /32 15 /16 1 7 /32
2 x 1 112 x 112
1.12
1'/4 1 25 /32 2'/4
2 x 1 1/4 x 2
1.58
1 9 /32 1 15 /32 1 9 /32
2 x 1 1/4 x 1112
1.16
1'/4 1 31 /32 1 23 /32
2 x 1 1/4 x 1 1/4
1.19
15 /16 1 11 /32 1 11 /32
2 x 1 1/4 x 1
0.90
27 /32 1 9 /32 1 11 /32
2 x 1 1/4 x 3/4
0.85
21 /32 1 1 8 /27
2 x 1 x 2
1.11
1 1 /8 1 25 /32 1 1 /4
2 x l x 1
0.89
27 /32 1 9 /32 1 11 /32
2 x 3/4 x 2
1.15
1 9 /32 2 3 /16 1
2 x 112 x 2
1.15
1 9 /32 2 3 /8 1 1 /4
21 12
2.40
1 5 /8 1 5 /8 1 5 /8
21/2 x 21/2 x 2
1.97
1 5 /16 1 5 /16 1 21 /32
21 12 x 21 12 x 1 112
1.53
1 3 /32 1 3 /32 1 21 /32
21 12 x 21 12 x 1 1/4
1.72
1 3 /32 1 3 /32 1 27 /32
21 12 x 21 12 x 1
1.34
25 /32 25 /32 1 11 /16
21 12 x 21 12 x 3/4
1.34
25 /32 25 /32 1 13 /16
21 12 x 21 12 x 112
1.34
25 /32 25 /32 2 1 18
21/2 x 2 x 21/2
1.99
1 21 /32 2 3 /32 1 21 /32
2 112 X 2 x 2
1.95
1 11 /32 1 5 /8 1 23 /32
21/2 x 2 x 1 112
1.57
1 2 13 /32 1 21 /32
21/2 x 2 x 1 1/4
1.57
1 1 1
21/2 x 2 x 1
1.40
25 /32 1 9 /32 1
21/2 x 2 x 3/4
1.35
25 /32 1 1
21/2 x 1 1/2 x 1 112
1.76
1 3 /32 1 1 3 /8
21/2 x 1 1/4 x 21/2
2.40
1 21 /32 2 7 /16 1 21 /32
21/2 x 1 x 21/2
2.04
1 2 23 /32 1 21 /32
21/2 x 3/4 x 21/2
2.00
1 2 11 /16 1 21 /32
21 12 x 112 x 21 12
2.46
1'/2 2 7 /32 1 1 12
Continues...
NOTE: Tee sizes are read Run x Run x Outlet
Continued on next page
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
O.
NET W1
r
INCHES
3
3.15
1 7 /8 1 2 1 /32
3 x 3 x 2 112
3.55
1 29 /32 1 29 /32 2 3 /8
3 x 3 x 2
3.19
1 75 /32 1 15 /32 1 31 /32
3 x 3 x 1 112
3.08
1 15 /32 1 15 /32 2 9 /32
3 x 3 x 1 1/4
3.10
1 75 /32 1 15 /32 2 7 /16
3 x 3 x 1
2.12
27 /32 27 /32 1 31 /32
3 x 3 x 3/4
2.39
27 /32 27 /32 2 3 /16
3 x 3 x 112
1.82
27 /32 27 /32 2 3 /8
3 x 21/2 x 3
3.08
1 7 /8 2 3 /8 1 31 /32
3 x 21/2 x 21/2
3.12
1 29 /32 2 11 /32 2 5 /32
3 x 21/2 x 2
2.28
1 15 /32 1 27 /32 1 31 /32
3 x 2 x 3
3.62
1 29 /32 2 17 /32 1 15 /16
3 x 2 x 2 112
3.56
1 29 /32 2 9 /16 2 5 /16
3 x 2 x 2
3.22
1 15 /32 1 31 /32 1 31 /32
3 x 1 112 x 3
3.13
1 29 /32 2 25 /32 2 3 /32
3 x 1 1/4 x 3
3.63
1 29 /32 2 25 /32 1 15 /16
3 x 1 x 3
3.20
1 31 /32 2 19 /32 2 3 /16
3 x 3/4 x 3
3.55
1 31 /32 2 29 /32 2 3 /16
3 112
5.20
2 17 /32 2 17 /32 2 17 /32
4
8.12
2 13 /32 2 13 /32 2 17 /32
4 x 4 x 3
6.70
2 1 /32 2 1 /32 2 21 /32
4 x 4 x 21/2
6.65
2 1 /32 2 1 /32 3 5 /32
4 x 4 x 2
5.82
1 1 15 /32 2 7 /16
4 x 4 x 1 112
3.94
1 11 /32 1 11 /32 2 17 /32
4 x 4 x 1 1/4
4.04
1 11 /32 1 11 /32 2 29 /32
4 x 4 x 1
3.72
1 1 2 9 /16
4 x 4 x 3/4
3.70
1 1 2 11 /16
40 3 x 4
7.05
2 25 /32 3 7 /32 2 17 /32
4 x 3 x 3
5.03
2 1 132 2 15 /32 2 15 /32
4 x 3 x 21/2
5.04
2 1 /32 2 15 /32 2 Z9 /32
4 x 3 x 2
5.87
1 1 31 /32 2 7 /16
4 x 21 12 x 4
7.19
2 25 /32 3 15 /32 2 27 /32
4 x 2 x 4
7.08
2 25 /32 3 19 /32 2 27 /32
Continued on next page
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
a
Ek
C F
611
Tee C x C x C- Wrot continued
5
NET WT
8.29
,,
INCHES
2 2 3
5 x 5 x 4
7.09
2 2 3
5 x 5 x 3
5.91
1 1 3
5 x 5 x 21/2
5.90
1 1 3
5 x 5 x 2
5.29
1 1 3
5 x 5 x 1 112
4.87
1'/32 1'/32 3
5 x 5 x 1 1/4
4.50
11 /16 " /16 3
5 x 5 x 1
4.20
9 /16 9 /16 3
5 x 4 x 5
8.53
2 4 3
5 x 4 x 4
8.17
2 1 /4 4 3
5 x 2 x 5
9.47
2 5 3
6
13.50
3 3 4'/32
6 x 6 x 5
11.67
2 2 4
6 x 6 x 4
10.17
2 2 3 "/16
6 x 6 X 3
8.92
1 1 3
6 x 6 x 21 12
8.11
1 1 3
6 x 6 x 2
7.78
1 1 3
6 x 6 x 1 112
6.86
1 1 3
6 x 6 X 1 1/4
6.66
29 /32 29 /32 3
6 X 6 x 1
7.19
9 /16 9 /16 3
6 x 6 x 3/4
7.18
9 /16 9 /16 4
6 x 6 x 112
7.17
9 /16 9 /16 4
6 x 4 x 6
16.60
3 5 4
6 x 4 x 1 112
9.62
15 /16 2 3
8
36.81
4'/16 4 5
8 x 8 x 6
27.86
3 3 5'/8
8 x 8 x 5
24.90 2 2 4
8 x 8 x 4
22.26
2'/16 2 4
8 x 8 x 3
20.01
1 1 4
8 x 8 x 21/2
19.02
1 1 4
8 x 8 x 2
18.01
1 /16 1 4
NOTE: Tee sizes are read Run x Run x Outlet
Consult price sheet for Made to Order items and
for minimum order quantities.
611 -HE
Heat Exchanger Tee
CxCxC - Wrot
Tube slips entirely through fitting on small end
of run. Sizes same as listed under 611 where tee
has one or more reductions on one e o run.
1 4 d1 74
711
TeeCxCxC - Cast
1 1 /4 x 112 x 1
0.48
3 /4 3 /4 7 A
1 114 x 112 x 112
0.50
9 /16 5 /8 1
1 112 x 112 X 11/4
0.70
7 /8 31 /32 1
2 x 2 x 3
3.11
1 1 1
2 x 1 x1 112
1.23
1 1'/4 1
2 x 3/4 x 3/4
0.84
21 /32 7 /8 1 1 /4
21 12 x 21 12 x 3
2.98
1 1 1
21/2 x 1112 x 2
2.02
1'/4 1 1
21/2 x 1 112 x 1 112
1.76
1 1 1
21 12 x 112 x 21 12
2.46
1'/2 2 1
3 x 3 x 4
6.96
2 2 1
3 x 21 /2 x 1 112
2.53
1 1 1
3 x 2 x 1 112
2.62
1 1 1
4 x 4 x 6
16.47
3 3 2
4 x 2 x 2
4.64
1 1 2'14
711 -A
Supply and Return Tee
CxCxC - Cast
112 0.17 13 /16 1
SLE L I-T
F
611 -2
Fitting TeeCxFtgxC - Wrot
APPROX. DIMENSIONS
NET WT. INCHES
112 0.07 1'/32 3 /8 7 /16
3/4 0.15 1 1 /2 17 /32
T
A
C C
Drop Tee Ca
APPROX. DIMENSIONS
NET WT. INCHES
NOM. SIZE LBS. A C
1
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST, ^ ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
TEES continued
TEES continued
F p F F
712
TeeCxCxF - Cast
713
TeeCxCxM -Cast
3/8
0.11
" /16
7 /16
1 /16
112
0.14
13 /16
7 /16
7 /16
3/4
0.33
1
21 /32
21 /32
1
0.54
1 1 /4
7 /8
7 /8
1 112
1.08
1
1
1
2
1.74
1
1
1
112 x 112 x 1/4
0.16
13 /16
1 12
1 12
112 x 112 x 3/8
0.15
13 /16
1 12
'12
112 x 112 x 3/4
0.23
15 /16
"/16
" /16
3/4 x 3/4 x 3/8
0.23
7 /8
'12
'12
3/4 x 3/4 x 112
0.24
57 /64
17 /32
17 /32
1 1/4 x 11/4 x 112
0.49
1'/4
9 /16
9 /16
1 1/4 x 11/4 x 3/4
0.55
1 5 /16
11 /16
11 /16
1 1/4 x 11/4 x 1
0.66
1 7 /16
7 /8
7 /8
1 x 1 x 112
0.34
1
9 /16
9 /16
1 x 1 x 3/4
0.42
1 3 /16
11 /16
" /16
1 112 x 1112 x 112
0.62
1
9 /16
9 /16
1 112 x 1112 x 3/4
0.70
1 7 /16
11 /16
11 /16
1 112 x 1112 x 1
0.79
1 1 /2
13 /16
13 /16
2 x 2 x 112
0.97
1
17 /32
17 /32
2 x 2 x 3/4
1.10
1 11 /16 11 /16
11 /16
2 x 2 x 1
1.23
1 3 /4
13 /16
13 /16
1/4
0.08
13 /16
9 /32
9 /32
11/4
0.76
1 7 /16
1
1
3/8 x 3/8 x 1/4
0.12
"/16
7 /16
7 /16
3/4 x 112 x 3/4
0.28
1
21 /32
11 /16
3/4 x 3/4 x 1
0.40
1
7 /8
7 /8
c J c
712 -5
DropTeeCxCxF - Cast
APPROX. DIMENSIONS 1
NET WT. INCHES
112 0.25 3 /8 9 /16 7 /8
3/4 0.38 1 /2 21 /32 1
698
Suction Line P -Trap
CXC - tarot
A major application of this fitting is on the suction
line of a refregeration compressor. The line is
looped, by use of the Suction Line P -Trap, to the
floor prior to being run vertically upwards to
prevent the drainage of oil back to the
compressor during shut down periods. Additional
P -Traps are used for each 20' or riser pipe. this
prevents high velocity build -up as the oil or liquid
begins to return to the compressor during this
shut down period.
112
0.36
5 3
3
6
5/8
0.45
5 2
3
6
3/4
0.58
5 2 3 /4
3
6
1
0.92
5'/4 2 21 /32
3
6
11/4
1.16
5 2
3
6'/8
1112 2.32 7 3 5 9
2 3.93 8 3 6 9 7 /16
Consult price sheet for Made to Order items and
for minimum order quantities.
1 /2 0.15 1 3 /32 7 /16
3/4 0.29 1 9 /32 9 /16
P111 _.t
714
TeeCxFxC - Cast
112
0.18
7 /16
9 /16
7 /8
112 x 3/4 x 112
0.27
7 /16
9 /16
1 3 /16
3/4
0.31
9 /16
11 /16
1
3/4 x 112 x 3/4
0.26
9 /16
9 /16
15 /16
1
0.52
23 /32
13 /16
1'/4
1 x 3/4 x 1
0.43
23 /32
23 /32
1 3 /16
1 x 112 x 1
0.42
3 /4
3 /4
1
1 1/4
0.70
7 /8
1
1 13 /32
1 1/4 x 3/4 x 11/4
0.62
7 /8
7 /8
1 7 /32
1 1/4 x 112 x 11/4
0.56
7 /8
7 /8
1 3 /16
1 112
1.00
1
1
1 9 /16
1 112 x 3/4 x 1112
0.88
1
1
1 13 /16
2
1.72
1' /4
1
1
2 x 3/4 x 2
1.57
1
1 1 /4
2
2 x 112 x 2
1.58
1 1 /4
1'/4
2
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
TRAPS
UNIONS
OR WA
633 -W
Union C x C - Wrot
1/8
0.10
5 /8
1/4
0.15
11 /16
3/8
0.22
7 /16
112
0.31
73 /32
3/4
0.33
3 /8
1
0.54
1 /2
733 A
Union C x C - Cast
1/4
0.10
11 /16
3/8
0.15
7 /16
112
0.22
13 /32
5/8
0.31
21 /32
3/4
0.31
3 /8
1
0.54
1 /2
11/4
0.76
'/2
11/2
1.04
23 /32
2
1.77
'/z
2112
3.25
1
3
4.75
1
Consult price sheet for Made to Order items and
for minimum order quantities.
■
■ ■
■
Fs�
112 0.23 1
APPROX. DIM. B
NOM. SIZE NET WT. /LBS. INCHES
3/4 0.35 1
1 0.55 1
733 -3
Fitting Union C x F - Cast
APPROX. DIM. A
NOM. SIZE NET VJT./LBS. INCHES
1/4 0.14 1
3/8 0.19 1
112 0.26 1
3/4 0.37 1
1 0.61 1
11/4 0.98 1
1 112 1.21 1
2 1.90 2
■
■ illillllll
■ :Iililll'
I
1/4
0.13
1
3/8
0.20
1
112
0.28
1
112 x 3/4
0.35
2
3/4
0.43
1
1
0.68
2'/8
11/4
0.95
2
1 112
1.35
2
2
2.17
2
21 12
4.13
3
VENTURI
4?
621
Venturi Insert - Wrot
Converts any tee into a special purpose Venturi or
scoop tee
1/2
0.01
3/4 0.02
1 0.03
11/4 0.04
Y's
!IrA
e s
748
90 °Y CxCxC -Cast
112 0.11 7 /32 7 /16
3/4 0.25 7 /16 5 /8
1 0.61 '12 13 /16
I
A
B
749
45 °Y CxCxC -Cast
112
0.15
1
7 /8
3/4
0.30
1
1
1
0.55
1
1
11/4
0.81
2
1
11/2
1.14
2
2
2
2.17
3
2
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
....... -,^ m
100 Series - Heavy Flared
500 Series - Flared
Adapters ......................... .............................23
Couplings ......................... .............................23
Elbows ........................... .............................23
Nuts ............................. .............................24
Tees ............................. .............................24
1509091:7099
The manufacturing plants at
South Glens Falls, NY,
Stuarts Draft VA Nawgdoches, TX
and Reynosa, Mexico manufacture
products under a Quality
Managernent System conforming
to the current revision of ISO-9001
International Standards
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART. IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455
ADAPTERS
COUPLINGS
��111111111
�illlllli -
14
Heavy Flared Adapter
APPROX. DIM.L
NOM. SIZE NET WT. /LBS. INCHES
0.60
1 1.2 3
}
1
. •1'1.1 -
APPROX. DIM. B
NOM. SIZE NET WT. /LBS. INCHES
1
3/4 0.48 2
1 1.03 2
1112 1.99 3
2 3.22 3
504
Flared Adapter FL x M — Cast
Consult price sheet for Made to Order items and
for minimum order quantities.
1 0 1
H eavy • •1 Coupling
APPROX. DIM.L
NOM. SIZE NET WT. /LBS. INCHES
1'i
1 1. 70 5
501 r B ----I
Flared Coupling FL x FL — Cast
A
NOM. SIZE NET VVE/1-13S. INCHES
112 0.45 2
3/4 0.60 2
1 1.24 3
11/4 2.18 3
11/2 2.65 3
2 4.03 4
ELBOWS
507
Flared 90° Elbow FL x FL — Cast
APPROX. DIM. B
NOM. SIZE NET WT./LBS. INCHES
112 0.54 1
3/4 0.77 1
1 1.60 2
2 5.39 3
1
Flar 91• El bo w
APPROX. DIM. B DIM. E
NOM. SIZE NET WT. /LBS. INCHES INCHES
1
3/4 0.69 1 1
1 1.43 2 2
1
Flared 90' Elbow FL x M — Cast
APPROX. DIM. B DIM. E
NOM. SIZE NET WT. /LBS. INCHES INCHES
0 .34 111/16 113/32
1112 2.80 3 2
3/4 0.55 1 1
1 1.34 2 2
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST ^ ^ ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
A A
i l
NOM. SIZE
NET VVT./LBS.
INCHES
112
0.29
1
3/4
0.58
2
1
0.88
3
1112
1.89
3
2
2.95
4
Consult price sheet for Made to Order items and
for minimum order quantities.
1 0 1
H eavy • •1 Coupling
APPROX. DIM.L
NOM. SIZE NET WT. /LBS. INCHES
1'i
1 1. 70 5
501 r B ----I
Flared Coupling FL x FL — Cast
A
NOM. SIZE NET VVE/1-13S. INCHES
112 0.45 2
3/4 0.60 2
1 1.24 3
11/4 2.18 3
11/2 2.65 3
2 4.03 4
ELBOWS
507
Flared 90° Elbow FL x FL — Cast
APPROX. DIM. B
NOM. SIZE NET WT./LBS. INCHES
112 0.54 1
3/4 0.77 1
1 1.60 2
2 5.39 3
1
Flar 91• El bo w
APPROX. DIM. B DIM. E
NOM. SIZE NET WT. /LBS. INCHES INCHES
1
3/4 0.69 1 1
1 1.43 2 2
1
Flared 90' Elbow FL x M — Cast
APPROX. DIM. B DIM. E
NOM. SIZE NET WT. /LBS. INCHES INCHES
0 .34 111/16 113/32
1112 2.80 3 2
3/4 0.55 1 1
1 1.34 2 2
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST ^ ^ ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
NUTS
I /,(
00
1• Nut — Cast
APPROX. DIM. B DIM. L
NOM. SIZE NET VVT. /LBS. INCHES INCHES
0.20 1 1 /16 1 1 12
1
TEES
511
Flared Tee FL x FL x FL — Cast
112 0.67 1 5 /8 1 5 /8 1 5 /8
3/4 1.09 2 2 2
1 2.08 2 5 /8 2 5 /8 2 5 /8
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Adapters ......................... .............................26
BrassPlug ......................... .............................27
Couplings ......................... .............................26
CrimpRings ....................... .............................26
CrimpTool ......................... .............................21
Elbows ........................... .............................26
Fitting Reducers .................... .............................26
Tees ............................. .............................26
Tube Cutter ........................ .............................27
'SOM11:2000
The manufacturing plants at
South Glens Falls, NY,
Stuarts Draft VA, Nacogdoches, TX
and Reynosa. Mexico manufacture
products under a Qual ity
Management System conforming
to the current revision of ISO -9001
International Standards
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
ADAPTERS
uI'II i =1�
wu
PEX603
Adapter PEX x F — Wrot
APP
NOM. SIZE NET WT./LBS. INCHES
112 0.123 2
3/4 0.207 2
PEX 604
Adapter '
APPROX. DIM. A
NOM. SIZE NET WT. /LBS. INCHES
0.110
0.196
MF■IE 11
PEX
Adapter PEX x • i — Wrot
APPROX. DIM. A
NOM. SIZE NET WT. /LBS. INCHES
0
0
1 '
111�1�1'q�ll I�I�111
P 600
Cou pling PEX x P EX — Wrot
APPROX. DIM.A
NOM. SIZE NET WT. /LBS. INCHES
11 .
3/4 0.056 2
COUPLINGS continued
,,
r— A
2 1
-
'
IIIII�III��
' •11 `
0.112
Cou
1 —
3/4 x 112 x 112
0.097
APPROX. DIM.A
NOM. SIZE NET WT. /LBS. INCHES
1 1
0
:1
2 1
A
�TYP
PEX607
Elbow PEX x PEX — Wrot
112 0.045 1
3/4 0.084 1 1 /16
A
PEX607 -FA
Faucet Elbow
PEX x Swivel FIP — Wrot
112 0.049 1'/16
PEX707 -3 -5
Drop Ear Elbow
PEX x FIP — Wrot
112 0.187 21/4
FITTING
REDUCERS
QQ � A —j
- E)Rf�
PEX600 -2
Fitting Reducer Ftg x PEX —Wrot
APPROX.
NUM. SIZE NET VJT./LBS. INCHES
112 0.035 1
3/4 0.059 1
TEES
jL ,���,,, � y'�o1�r�
•
Tee PEX x PEX x P EX — Wrot
112 0.070 2 1 1 —
3/4
0.097
2 1
1 —
1 12 x 112 x 3/4
0.112
2 1
1 —
3/4 x 112 x 112
0.097
2 1
1 1
3/4 x 112 x 3/4
0.112
2 1
1 1
3/4 x 3/4 x 112
0.099
2 1
1 -
CRIMP RINGS
N r
MI
3 FA
PEX198
Crimp Rings
(Black)
APP
NOM. SIZE
NET WT./LBS. INCHES
112
0.013 0.325
3/4
0.017 0.325
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
CRIMP TOOL
Crimp Tool
APPROX.
NOM. SIZE NET WT. /LBS.
11
112 3.005
3/4 3.005
1 4.000
E:1
PEX100
Tube Cutter
0.03
Brass P lugs
APPROX.
NOM. SIZE NET WT. /LBS.
0
11
0.0457
0.0801
Consult price sheet for Made to Order items and
for minimum order quantities. ,
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Copper Insert Fittings for Polybutylene
Couplings ......................... .............................29
CrimpRings ....................... .............................29
Elbows........................... .............................29
Faucet Connectors .................. .............................29
Tees............................. .............................29
�.
IS0900 -.. ll=;::l
The manufacturing plants at
South Glens Falls, NY,
Stuarts Draft VA Nacogdoches, TX
and Reynosa, Mexico manufacture
produM under a Quality
Management System conforming
to the current revision of ISO -9001
International Standards
m NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
' TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574295.3221 • FAX: +1.574.295.3455
COUPLINGS
PB600
C oupling Barb x Barb
APPROX.
7 NOM. SIZE NET WT. /LBS.
11
0.06
ELBOWS
PB607
90' Elbow — Barb x Barb
112
0.04
3/4 0.06
FAUCET
CONNECTORS
s4 ' � :
PB600 -FA
Straight Faucet Connector —
Barb x Swivel FIPS
112 without nut & washer 0.03
Consult price sheet for Made to Order items and
for minimum order quantities.
FAUCET
CONNECTORS
PB607 -FA
90' Elbow Faucet Connector —
Barb x Swivel FIPS
112 without nut & washer 0.04
TEES
it p
PB611
Tee — Barb x Barb x Barb
112 0.05
112 x 112 x 3/4 0.10
3/4 0.10
3/4 x 3/4 x 112 0.08
3/4 x 112 x 3/4 0.10
3/4 x 112 x 112 0.08
CRIMP RINGS
Crim Ring Coppe
APPROX.
NOM. SIZE NET WT. /LBS.
11
3/4 0.02
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.2953221 • FAX: +1.574.295.3455
Wrot and Cast DWU Fittings
Adapters .......................... ..........................31 -33
Bushings ......................... .............................33
Cleanouts ......................... .............................33
Closet Flanges ..................... .............................34
Couplings ...................... ............................... 34
Elbows ........................... ..........................35 -36
Plugs ............................ .............................36
ReturnBends ...................... .............................40
Tees ............................. .............................31
Test Caps & Tees ................... ..........................31 -38
Traps ............................. ..........................39 -40
T -Y's ............................. .............................38
Y ' s ............................... .............................38
IS09001: 7 000
The manufacturing plants at
South Glens Falls, NY,
Stuarts Draft, V& Nacogdoches, TX
and Reynosa, Mexico manufacture
products under a Quality
Management System conforming
to the current revision of ISO -9001
International Standards
m NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST • ELKHART, IN 46516 -4740 • USA • PH. 1.800.234.0227
TECH SERVICES PH: 1.888,446 4226 • FAX: 1.800234.0557 • INTERNATIONAL SERVICE PH: +1.574.2953221 • FAX: +1.574.295.3455
ADAPTERS - SLIP JOINT
801 -2 -7
DWV Fitting Trap Adapter
Ftg x SJ — Cast
APPROX. DIM. B
NOM. SIZE NET WT./LBS. INCHES
11/4 x11 /40.D. 0.25 1 19 /32
901 -2 -7
DWV Fitting Trap Adapter
Ftg x SJ — Wrot
APPROX. DIM. B
NOM. SIZE NET VVT./LBS. INCHES
1112 x 1112 O.D. 0.29 1 7 /16
1112 x 11/4 O.D. 0.24 1 7 /16
oil 1w
901 -7
DWV Trap Adapter
C x SJ — Wrot
11/4 x 1 1/4 O.D. 0.21 21 /32
1112 x 11/2 O.D. 0.27 3 /4
1 112 x 1 1/4 O.D. 0.24 7 /6
Consult price sheet for Made to Order items and
for minimum order quantities.
903 -7
DWV Trap Adapter
FxSJ — Wrot
1 1/4 x 1 1/4 O.D. 0.32 1 7 /16
1112 x 1112 O.D. 0.42 1 7 /16
1112 x 11/4 0. D. 0.43 1 19 /32
FF
—t 3 x 4 2.78 3
904-7
DWV Trap Adapter
M x SJ — Wrot
11/4 x 1 1/4 O.D. 0.41 1 3 /4
1112 x 1 112 O.D. 0.51 1 25 /32
1 1 /2 x 1 1/40,D. 0.49 1 29 /32
805
DWV Soil Pipe Adapter
C x Spigot — Cast
Joins copper tube to cast iron soil pipes.
1 1/4x2
0.93
3 9 /32
2 x 4
2.52
3
3
1.56
2
4
1.23
13 /16
4
2.23
3
905
DWV Soil Pipe Adapter
C x Spigot — Wrot
Joins copper tube to cast iron soil pipes.
1112 x 2 0.60 3 7 /16
2 0.44 2 9 /16
805 -N
DWV No Hub Soil Pipe Adapter
C x No Hub— Cast
1 112 x 2
0.42
1 7 /32
2
0.40
1 3 /16
3
0.75
1 3 /16
4
1.23
1 7 /32
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.422 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
31
ADAPTERS —
SPECIAL LEAD
�4
fi
801 -T
DWV Trap Adapter
C x OR D. Tube — Cast
11 /4x11 /40.D. 0.21 '/a
1112 X 1112 0. D. 0.22 '/32
1112 x 11/4 0. D. 0.20 9 /32
ADAPTERS —
THREADED
802
DWV Adapter
CxM — Cast
it I II
1 1/4 0.23 15 /16 '/16
1 1/4 x 1112 0.41 1 '12
1 112 0.25 1 '/16
2 0.33 1 ' /16
3 0.92 1 3 /4
19 is
802 -C
DWV Flush Adapter
CxM — Cast
APPROX. DIM. B i
NOM. SIZE NET VVT./LBS. INCHES INCHES
11/4 0.16 15 /16 '/16
1112 0.20 15 /16 9 /16
2 0.23 1 5 /6
ADAPTERS — THREADED continued
ouc -r
DWV Threaded Piece
CxM —Cast
Makes slip joint connection when soldered to the
end of tube and slip joint nut and washer added.
11/4 0.05 3 /8
1112 0.05 3 /a
2 0.05 3 /e
803
DWV Adapter
CxF — Cast
APPROX. DIM. A
NOM. SIZE NET WT./LBS. INCHES
3 1.45 1
4 2.31 1
903
DWV Adapter
CxF — Wrot
11/4 0.19 27 /32
1112 0.25 29 /32
2 0.41 1
:1
DWV Fitting `d.p•
APPROX. DIM. B
NOM. SIZE NET VVT. /LBS. INCHES
1
■I:
.,
DWV Fitting Adapte
APPROX. DIM. B
NOM. SIZE NET VVT. /LBS. INCHES
1
N 111111
804
DWV Adapter
CxM — Cast
1 112
0.34
1
1112 x 2
0.55
1
1112 x 1 1/4
0.31
21 /32
2
0.43
'/8
2 x 1 112
0.52
15 /16
3
1.35
1
4
2.59
2'/32
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST- • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
ADAPTERS — I BUSHINGS I CLEANOUTS
THREADED continued
�lNIIiI
904
DWV Adapter
C x M – tarot
11/4 0.30 1
11/4 x 1112 0.37 1
FIRM
804 -T �---- i —I
DWV Trap Adapter
ORTubexM – Cast
1 1/4 0 D. x 1 112 0.44 1
M r // ■ 1iiI1S
■ �u
_v
0
DWV Fittin X 1.1 •
1
APPROX. DIM. B
NOM. SIZE NET WT. /LBS. INCHES
1 1
2 0, 71 2'132
Consult price sheet for Made to Order items and
for minimum order quantities.
Aft
E3B
:1
D WV External
Bushin
1
APPROX. DIM.A
NOM. SIZE NET WT. /LBS. INCHES
0 . 6 1 V/32
4 x 3 1.12 1
3 x 1112 0.60 1
4 x 2 1.16 1 /a
901 -2
DWV External Bushing
Ftg x C – Wrot
APPROX. DIM. A
NOM. SIZE NET WT./LBS. INCHES
1112 x 11/4 0.13 1
2 x 1112 0.19 1
2 x 11/4 0.19 1
•1
DWV Fittin Flush Bushin
/ /
APPROX. DIM. B DIM. C
NOM. SIZE NET WT. /LBS. INCHES INCHES
1
816
DWV Fitting Cleanout
Ftg x Cleanout w /Plug – Cast
APPROX. DIM. 13
NOM. SIZE NET WT./LBS. INCHES
1 1/4 0.49 2
1112 0.60 2 /4
2 0.87 2
3 2.37 3
4 3.99 3
816 -S
DWV Flush Fitting Cleanout
Ftg x Cleanout w /Plug
– Cast
PPP
NOM. SIZE NETVVT./LBS.
INCHES
11/4 x 3/4 0.20
1
1112 x 1 0.29
1'/16
2 x 1112 0.42
1
3 x 2 112 0.96
1
4 x 3 2.25
2'/8
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST ^ • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
CLOSET FLANGES
»ms�c
■rte
851
DWV Closet Flange
C — Cast
4 1.45 5 /6 7 6
40 3 2.18 1 7 6
--------- - - - - -- ....... .. . . .............
—
I .
951
DWV Closet Flange
C — Wrot
4 x 3 0.84 1 6 6
l - __ l
851 -C
DWV Closet Flange
C — Cast
4 x 3 1.31 1 1 12 6 6
801
DWV Coupling
CxC — Cast
3 x 2
0.70
17 /16
3 x 1 112
0.68
15 /16
4 x 3
0.98
9 /32
4 x 2
1.34
1
901
DWV Coupling
CxC — Wrot
APPROX. DIM. A
NOM. SIZE NETWT./LBS. INCHES
1 1/4 0.07 3 /32
1112 0.09 3 /32
1112 x 1 1/4 0.13 5 /16
2 0.14 3 /32
2 x 1112 0.19 15 /32
3 0.45 3 /32
4 0.57 1 /e
901 -RP
DWV Repair Coupling (No Stop)
CXC — Wrot
1112
0.09
1
2
0.14
1
3
0.42
1
4
0.57
2
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455
ELBOWS
8I•
1 bo
• APPROX. DIM.0
NOM. SIZE NET WT. /LBS. INCHES
4 2.47 1
•1•
1 Elbo
APPROX. DIM.0
NOM. SIZE NET WT. /LBS. INCHES
1
1112 0.21 9 /16
2 0.38 13 /16
3 0.78 1
0
DWV 45' Fitting Elbo
APPROX. DIM. B DIM. C
NOM. SIZE NET WT. /LBS. INCHES INCHES
Il k
0
1 Elbo
APPROX. DIM.B DIM.0
NOM. SIZE NET WTJLBS. INCHES INCHES
1
1112 0.21 1 9 /16
2 0.39 1 13 /16
3 0.84 1 7 /8 1
FE
�LJ
807
DWV 90° Elbow
CxC — Cast
APPROX. i
NUM. SIZE NET WT./LBS. INCHES INCHES
1 112 x 1 1/4 0.43 1 1
2 x 1 112 0.71 1 1
3 2.30 2 2
4 3.92 3 3
907
DWV 90° Elbow
CxC — Wrot
11/2 0.32 1'/16 1
1 1/4 0.18 1 1
2 0.58 1 1
Consult price sheet for Made to Order items and
for minimum order quantities.
3 1.20 2 2
•1
DWV 90' Long Radius Elbow
APPROX. DIM.0
NOM. SIZE NET WT. /LBS. INCHES
0 .41 2
2 0.62 2
i
SI
DWV 90'Fitting Elbo
APPROX. DIM. B DIM. C
NOM. SIZE NET WTJLBS. INCHES INCHES
:' 4"/16 3
907 -2
DWV 90' Fitting Elbow
Ftg x C — Wrot
APPROX. DIM. B DIM. C
NOM. SIZE NETW11LBS. INCHES INCHES
1 1/4 0.19 1 1
1112 0.33 2 1 7 /16
2 0.59 2 1
3 1.21 3 2
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
3
ELBOWS continued
807 -3
DWV 90° Elbow
CxF — Cast
NOM. SIZE NET WT. /LBS. INCHES INCHES
1
2 1.15 17/8 211/16
A
V4 - . , -
807
DWV •1' E I 11
Cast APPROX. DIM.0 DIM E
NOM. SIZE NET WT. /LBS. INCHES INCHES
0.66
i
807 -9
DWV 90° Elbow w /Side Inlet
CxCxC — Cast
3 x 3 x 2 2.55 2 7 /8 1 5 /8 2 7 /8
837 LEI
DWV 90 ' Double Elbow
CxCxC—Cast
APPROX. DIM. C DIM. G
NOM. SIZE NET WT. /LBS. INCHES INCHES
1
2 x 1112 x 1112 0.97 1 5 /8 1 1 12
go C
0
1 11
Cast APPROX. DIM.
NOM. SIZE NET WT. /LBS. INCHI
1
1112 0.28 '/4
2 0.48 11 /32
3 0.99 17 /32
809
DWV 11 1 /4° Elbow
CxC — Cast
APPROX.
NOM. SIZE NETWT/LBS. INCHES
1112 0.22 5 /32
2 0.38 3 /16
••0
DWV •1' Elbow
APPROX. DIM.
INOM. SIZE NET WT. /LBS. INCHE
0.24 13 /16
2 0.44 1 1 /8
3 0.95 1 7 /8
1
L
861 -LH
DWV 90° Elbow
w /Low Heel Inlet
CxCxC — Cast
APPROX.
NOM.SIZE NETWT./LBS. INCHES INCHES
3 x 3 x 2 2.43 2 7 /8 1 9 /32
818 A.S.A,
DWV Plug
M — Cast
NOM. SIZE
APPROX.
NET WT./LBS.
INCHES
3/4
0.08
23 /32
1
0.12
29 /32
11/4
0.19
31 /32
1 112
0.21
1 3 /32
2
0.34
15 /16
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
TEES
_ -_. r _.
811 -14 °
811 DWV Tee t
DWV Tee CxCxF - Cast
CxCxC - Cast
3 2.84 2 1 2
3 x 3 x 2 1.82 2 1'/8 1
3 x 3 x 1 112 1.58 2 15 /16 1
4 4.92 3 2 3
4 x 4 x 3 3.49 3 "/32 1 2
4 x 4 x 2 2.91 2 1 1
}.
- _ I a �
3
1
911
DWV Tee
CxCxC - tarot
11/4
0.32
1'/8
13 /16
1' /8
1 112
0.49
1
29 /32 1
1112 x 1112 x 11/4
1.58
2
15 /16
1
2
0.78
1
1' /8
1
2 x 2 x 1 112
0.73
1
15 /16
1
2 x 2 x 1 1/4 0.51 1'/2 13 /16 1 /8
20 1 1/2 x 2 0.80 1 1 1
20 1 1/2 x 1 112 0.73 1 1'A 1
Consult price sheet for Made to Order items and
for minimum order quantities.
1 1 0.88 2 13 /16 1
2 1.57 2 1 1
2 X 2 X 1 112 1.17 2 7 /8 1
wv
811 -15
DWV Tee
CxFxF - Cast
C
I
CxUxCXC -Cast
11/4
0.65
1 3 /4 1
11/2
0.85
1 13/16 113/16
11/2x11/2x11/4x11/4
0.72
1 3 /4 75 /32
2
1.38
1'/8 1 1
2 x 2 x 1 1 /2 X 1 112
0.99
1 7 /8 1
2 x 2 x 1 1 /4 x 1 1/4
0.93
1 "/32 25 /32 1
2 x 1 1 /2 x 1 1 /2 x 1 112 0.94 1 25 /32 1' /16
3 x 3 x 2 x 2 2.36 2 1'/8 1' /8
3 x 3 x 1 1 /2 x 1 1 12 1.51 2 " /32 1" /32
FNOM. APPROX. DIMENSIONS NET WT. INCHES
SIZE LBS. C D L M
TEST CAPS
917 -B
Test Caps - Copper
C - Wrot
112
0.01
3 /16
3/4
0.01
3 /16
1
0.01
1 /8
11/4
0.01
'/4
1 112
0.01
1 /4
2
0.02
'/4
3
0.03
'A
4
0.05
5 /16
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST^ . ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
11/4 0.73 1 1'/2 15/32
TEST TEES
4& . . �_ T
1
814
DWV Test Tee
C x C x Cleanout w /Plug — Cast
APPROX. DIM. E DIM. F
_NOM.SIZE NETWT./LBS. INCHES INCHES
1112 1.00 2'/16 1'/8
2 1.35 2 1 '/32 1
3 3.78 3 1
T -Y's
r
0
812
DWV Long Turn T -Y
CxCxC — Cast
11/4
0.93
2 1
2
13 /32
1112
0.87
3
2'18
3
'/16
2
1.84
4'/4
2
4
1 12
2 x 2 x 1112
1.07
3
2
3/32
'/3z
3
3.49
6'/16
4732
6
3 /4
3 x 3 x 2
2.78
4'/e
3'/16
4
3 /32
°�
J
836 KJ
DWV Double Long Turn T -Y
CxCxCxC — Cast
1112
1.25
3
2
3
'/32
2
0.87
3
2'/8
3
'/16
2 x 2 x 1112 x 1112
1.96
3
2
3'/32
'/32
2 x 2 x 11/4 x 11/4
2.67
3"/16
2
3'/32
'/32
Y's continued
�f
810
DWV 45° Y
CxCxC — Cast
4tO4JCm
11/4
0.60
2 2
3 /8 -
11/2
0.94
2 2
'/2 —
2
1.26
2'/8 2
11 /32 —
2 x 2 x 1112
1.15
2 11 /16 2
3 /16 —
2 x 2 x 1 1/4
1.01
2 2 1 '/32
'/16 —
2x1 112 x 2
1.16
2 11 /32 2
"/32 —
2x1 112 x 1112
0.84
2 2
5 /16 —
3
3.19
4 4
45 /64 -
3 x 3 x 2
2.02
3 1 '/32 3
'/8 —
3 x 3 x 11 12
1.69
374 2
- 3 /16
4
5.55
5 5 1 —
4 x 4 x 3
3.96
4"/16 472
5 /16 -
4 x 4 x 2
2.90
4'/32 3 13 /16
— 3 /8
834
DWV 45' Double Y
CxCxCxC —Cast
2 1.90 2'/8 278 1 732 —
2 x 2 x1 112 x 1112 1.26 2 "/16 2 3 /16 —
3 4.20 4 0/32 25 /32 -
3 x 3 x1 112 x 1112 2.09 3'/4 2 — 5 /16
Consult Price sheet for Made to Order items and
for minimum order quantities,
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
F
890
3 x 5 DWV Drum Trap
w /Bottom Inlet
C x F x Cleanout w /Plug — Cast
APPROX.
NET WT. INCHES
1112 1.97 3 1'12 2
WKO �
S
1
891 t
3 x 6 DWV Swivel Drum Trap
C x C x Cleanout w /Plug — Cast
APPROX. DIMENSIONS
NET WT. INCHES
1112 2.90 6 1'12 1 3
..
DWV ' .1 w/Cleano
Cl eanout ' 1 — Castl
APPROX. DIMENSIONS
NET WT. INCHES
NOM. SIZE LBS. A E J K
:1 1 2'132 2'12 3
2 2.66 P/8 2 3 4
Consult price sheet for Made to Order items and
for minimum order quantities.
ET AM0
..
DWV ' .1
APPROX. DIMENSIONS
NET WT. INCHES
NOM. SIZE LBS. A E J K
1 1' 2/32 2 3
L
884
DWV P -Trap w /Cleanout
C x C x Cleanout w /Plug
— Cast
APPROX. DIMENSIONS
NETWT.
INCHES
11/4 1.21 1 1
2'14
3
1112 1.53 1
2'12
3 17 /32
2 2.26 1 1
3
4
3 5.74 2 1
4
5
885
DWV P -Trap
CxC — Cast
11/4 1.09 1 1 2 3
1112 1.45 1 2'12 3
2 2.11 1 7 /8 1 3 4
3 5.17 2 1 4 3
1 112 1.86 1 3 2 3
2 2 1 75 /32 3 3 3
■
892 -3
DWV P -Trap w /Union Joint
FxSJ — Cast
2 2.89 1 3 3 3
DWV P -Trap w /Union Joint
F x SJ x Cleanout w /Plug — Cast
APPROX.
NET WT. INCHES
1112 1.88 1 2 2 3
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. ^ ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1800 234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
bzj c
DWV P -Trap w /Union Joint
CxSJ — Cast
TRAPS
TRAPS Cont.
E
875 -S
DWV Trap Upturn
MxS — Cast
1112 1.20 1 41 /64 1 9 /64 4
R ETURN BENDS
878
DWV Return Bend w /Cleanout
C x C x Cleanout w /Plug — Cast
APPROX. DIMENSIONS
NETWT. INCHES
11/4 0.81 1 17 /32 2 —
1112 0.98 1 15 /32 2 —
3 3.34 1 15 /16 4 -
2 1.40 1 13 /32 3 —
879
DWV Return Bend
CxC — Cast
11/4
0.76
1 17 /32
2 —
11/2
0.90
1 15 /32
2'12 —
1 112 x 1 112 o.D.
1.00
1 15 /32
2 1 /2 —
2
1.25
1 13 /32
3 —
2 x 1112 O.D.
1,23
1 17 /32
3 1 19 /32
2 x 1112
1.37
1 17 /32
3 1 19 /32
3
2.77
1 15 /16
4 —
Consult price sheet for Made to Order items and
for minimum order quantities.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Engineering Data Engineering Data continued
Brazing Alloy
Consumption...................... .............................45
Brazing Fittings
Dimensions....................... .............................49
Friction Loss Allowances ........... ............................... 56
Installation Techniques .............. ..........................86 -87
Tolerances........................ .............................49
Copper Tube Fittings
Brazing Information ................. .............................45
Fitting Terms and Abbreviations ..... ............................... 42
Plumbing System Failures .......... ............................... 43
Rated Internal Working Pressures ... . . ... . . .. . . . . ... . . . . ... . . . ... 46 -47
Solder and Flux Requirements ...... ............................... 45
Solder Joint Specification .......... ............................... 44
Tolerances........................ .............................63
Types of Joints ..................... .............................42
Copper Water Tube
Comparative Data with Iron Pipe ....... . .... . . ............. . .... . .. 54
Dimensional Data ................... ..........................50 -53
Expansion and Contraction ......... ............................... 55
Internal Working Pressures . . . . .... . . . ................. . ........... 57
Selection of Tube Sizes ............ ............................... 56
Tolerances ........................ ..........................50 -53
Types, Standards, Applications, Tempers and Lengths ... . . . ...... . .. . .. 84
Water Flow and Friction Loss .... ............................... 58 -83
Frequently Asked Questions ...... ............................... 90
Joints
Abbreviations ...................... .............................42
Brazing........................... ..........................86 -87
Soldering......................... .............................85
Types............................ .............................42
Solder and Flux
Ratings........................... .............................46
Requirements ...................... .............................45
Solder Joint Fittings
Dimensions ....................... .............................48
Friction Loss Allowances .......................................... 56
Installation Techniques .............. .............................85
Tolerances ........................ .............................48
Specifications
Tolerances
Fittings............................................... 44,48 -49
Tubing......................... ..........................50 -53
Valves
Friction Loss Allowances ....... ............................... 56
Working Pressures
Joints......................... ..........................46 -47
Tubing............................................... 50 -53,57
Installation Instructions
The Fine Art of Brazing ........ ............................... 86 -87
The Fine Art of Soldering ......... ............................... 85
Polybutylene Installation ......................... . . .... . . . .... . . 89
Polyethylene (PEX) Installation ... ............................... 88
Numerical Index
Numerical Index .......................... . ..................... 92
rsoeoo+:zooa
The manufacturing plants at
South Glens Falls, NY,
Stuarts Draft VA, Nacogdoches, TX
and Reynosa, Mexico manufacture
products under a Quality
Management System conforming
to the current revision of ISO -9001
International Standards
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.2953455
Copper
Tube Fittings
TYPES OF JOINTS
Flared Joint — The principle of the flared joint was first developed
for copper tube plumbing in 1928 by NIBCO. The flared type joint is
wholly a mechanical means of joining copper tubes. The tube nut is
placed over the end of the copper tube to be joined; the tube end then
is flared out at an approximate 45 degree angle by a flaring tool. The
flared end is then drawn up by the tube nut so the inside surface is
tightly secured against the ball seat of the fitting. This joint can be
readily dismantled at any time and is, in effect, a type of union
connection. Its use is generally restricted to soft (annealed) copper
tubes since hard drawn tubes would be subject to splitting when
flared (if the ends were not previously annealed). The flared ends of
NIBCO Flared Fittings are produced to the requirements of ASME
616.26, "Cast Copper Alloy Fittings for Flared Copper Tube."
Solder Joint — NIBCO pioneered the development of
the solder joint and its application to the field of copper tube piping.
Today the solder joint is widely adopted, as evidenced by the
majority of cities and states that have written codes to include
copper tube and solder joints as desirable for general plumbing,
water lines, vent, stack, waste and drain lines, as well as other uses
in industry. Testing has shown that often the solder joint has greater
strength than the tubes being joined, depending upon the soldering
alloy selected. While the method of preparing a solder joint is an
exacting art to insure a full strength joint, it can be readily mastered
by skilled tradesmen. It is for this reason — to insure the public of
the protection afforded by properly prepared joints — that NIBCO
products are marketed through the reputable sources of supply to the
piping trades. Important procedures for preparing a solder joint are
graphically illustrated in this catalog on page 95.
Brazed Joint— This type of joint has long been used wherever and
whenever critical situations have been encountered in copper piping.
The joint itself is completed much in the same manner as the solder
joint; however, considerably more heat and several refinements of
technique require separate procedures that are described further in
this catalog on pages 96 -97.
Threaded Ends — To adapt copper tube to equipment having
National Standard Pipe Taper (NPT) threads or to add copper tube to
existing iron pipe installations or other threaded connections, NIBCO
provides fittings having both external and internal NPT threads.
These threaded ends are produced to the requirements of ASME
131.20.1, "Pipe Threads, General Purpose (Inch)."
Flanges — To adapt copper tube to equipment having flanged
connections, or to add copper tube to flanged pipe installations or
other purposes, NIBCO provides flanges. The flanges are produced in
two standard types widely used in this field where copper tube can
serve — Class 150, comply with ASME 1316.24, "Cast Copper Alloy
Pipe Flanges and Flanged Fittings Class 150, 300, 400, 600, 900,1500
and 2500 "; and Class 125, which conform to MSS SP 106, "Cast
Copper Alloy Flanges and Flanged Fittings Class 125, 150 and 300."
Barbed Insert Fittings for Polybutylene (PB) — NIBCO offers a
complete line of copper barbed insert fittings for joining PB tube. The
insert fittings are produced to the requirements of ASTM F 1380.
Along with the insert fittings are copper crimp rings, which, when
properly installed, provide a leak -tight mechanical joint. Transition
fittings are available for adapting to new or existing threaded or
solder joint ends.
Barbed Insert Fittings for PEX — NIBCO offers a complete line of
copper barbed insert fittings for joining PEX tube. The insert fittings
are produced to the requirements of ASTM F 1807. Along with the
insert fittings are copper crimp rings, which, when properly installed,
provide a leak -tight mechanical joint. Transition fittings are available
for adapting to new or existing threaded or solder joint ends.
Fitting Terms and Abbreviations
C
Female solder cup
Ftg
Male solder end
F
Female NPT thread
M
Male NPT thread
Hose
Standard hose thread
Hub
Female end for soil pipe
Spigot
Male end for soil pipe
No Hub
Used with mechanical coupling
O.D. Tube
Actual tube outside diameter
S
Straight thread
SJ
Slip joint
FL
Flared
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Failure in a copper plumbing system is rare, but may occur due to a variety
of reasons. The most common causes of failure are:
Excessive fluid velocity causes erosion - corrosion or impingement (to strike
or hit against) attack in the tube and /or fitting. For this reason, the copper
plumbing industry has establish design velocity limits for copper plumbing
systems to the following:
Hot Water > 140 °F (60 °C) 2 to 3 feet per second
(0.6 to 0.9 meters per second)
Hot Water 140 °F (60 °C) 4 to 5 feet per second
(1.2 to 1.5 meters per second)
Cold Water 5 to 8 feet per second
(1.5 to 2.4 meters per second)
2. Localized high velocities and /or turbulence. The presence of a dent, tube
ends which are not reamed or deburred before soldering, and sudden
changes in direction can all cause localized high velocity conditions.
3. Flux Corrosion is typified by pin hole leaks, generally in the bottom of a
horizontal line. Fluxes are mildly corrosive liquid or petroleum -based
pastes containing chlorides of zinc and ammonia. Unless the flux is
flushed from the system, it will lay in the bottom of the tube and remain
active. ASTM B 813, "Liquid and Paste Fluxes for Soldering Applications
of Copper and Copper -Alloy Tube," limits the corrosivity of soldering
fluxes and ensures that these fluxes are flushable in cold water, which
facilitates easy removal of flux residue following installation.
4. Galvanic Corrosion may be defined as the destruction of a material by
electrochemical interaction between the environment and the material.
Generally, it is slow but persistent in character and requires the presence
of dissimilar metals. Galvanic corrosion requires the flow of an electric
current between certain areas of dissimilar metal surfaces. To complete
the electric circuit, there must be two electrodes, an anode and a cathode,
and they must be connected by an electrolyte media (water) through
which the current can pass. The amount of metal which dissolves at the
anode is proportional to the number of electrons flowing, which in turn is
dependent upon the potential and resistance of the two metals. The use
of dissimilar metals in a plumbing system may or may not create a
problem. For instance, copper and steel are perhaps the most common
dissimilar metals found together in a plumbing system. In closed systems,
such as a chilled or heating water piping, the use of dissimilar metals may
not create a serious problem; this is because there is virtually no oxygen
in the water and corrosion relations tend to be stifled. Where dissimilar
metals must be used, some codes require that they should be separated
by dielectric union or a similar type of fitting. The effectiveness depends
upon; distance between the metals on the electromotive -force series
(EMF) chart, ratio of cathode to anode area, degree of aeration, amount of
agitation, temperature, presence of dissolved salts, and other factors.
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
ABBREVIATED EMF SERIES
(Electromotive -Force Series; Common Piping Materials in Sea Water)
CATHODE ( +) Passive
GOLD — Fixtures, Faucets, Plating
PLATINUM
SILVER — Brazing alloys, Silver- bearing solders
TITANIUM — Condenser tubes
MONEL (67% Ni - 33% Cu) — Specialty piping & equipment
CUPRO- NICKEL — Condensers, Marine, Nuclear
COPPER — Pressure, DWV, Gases, Air, Refrigeration, etc.
BRASS (85/15 - Red) — Cast fittings, Valves
BRASS (70/30 - Yellow) — Gas - cocks, Fittings, Connectors
LEAD — Solder, Pipe, Sheet, Coating, Lining
TIN — Solders, Coating, Lining
CAST IRON — Pressure, DWV
WROUGHT IRON — Pressure
MILD STEEL — Fire Protection
ALUMINUM — Refrigeration, Irrigation, some Solar
GALVANIZED STEEL —Pressure, DWV
ZINC — Coatings, Linings, some Fittings
MAGNESIUM — Water Heater Anodes, Cathodic protection for pipelines
ANODE ( -) Active; Sacrificial Material
5. Dezincification is a type of corrosion in which brass dissolves as an alloy
and the copper constituent redeposits from solution onto the surface of the
brass as a metal, but in the porous form. The zinc constituent may be
carried away from the brass as a soluble salt, or may be deposited in place
as an insoluble compound. Dezincification is normally associated with
brass valves where the zinc content exceeds 15 %. Generally, areas of high
stress, such as valve stems and gate valve bodies, are primary targets of
attack.
6. On rare occasion problems of corrosion by aggressive water, possibly
aggravated by poor design or workmanship, do exist. Aggressive, hard well
waters that cause pitting can be identified by chemical analysis and treated
to bring their composition within acceptable limits. Typically these hard
waters are found to have high total dissolved solids (t.d.s.) including
sulfates and chlorides, a pH in the range of 7.2 to 7.8, a high content of
carbon dioxide (CO2) gas (over 10 parts per million, ppm), and the presence
of dissolved oxygen (D.O.) gas. Soft acidic waters can cause the annoying
problem of green staining of fixtures or "green water ". Raising the pH of
such waters to a value of about 7.2 or more usually solves the problem, but
a qualified water treatment specialist should be consulted.
7. Aggressive soil conditions can be a cause for external corrosion of copper
piping systems. Non - uniform soil characteristics, such as different soil
aeration, resistivity, or moisture properties, between adjacent sections of
tube can create galvanic corrosion cells. Soils contaminated with high
concentrations of road salts or fertilizers containing ammonia, chlorides,
and nitrogen are known to combine with water to form acids. Any metal
pipe laid in ash or cinders is subject to attack by the acid generated when
sulfur compounds combine with water to form sulfuric acid.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Copper Tube Fittings
continued
1. Soldering Clearance (between the outside of the tube and the
inside diameter of the solder cup) and the Depth of the Solder
Cup (into which the tube is inserted).
Soldering
Nominal Maximum
Size I. D. of
of Fitting Fittin
(Inches) Inch (
Minimum
0. D. of
Tube
Inch (mm)
or• p D epth
Maximum
Clearance
for Solderin
Inch (mml
Depth of
Solder Cup
Inch (mm)
1/4
0.381 (9.66)
0.374 (9.50)
0.007 (0.18)
0.31 (7.9)
3/8
0.506 (12.85)
0.499 (12.67)
0.007 (0.18)
0.38 (9.7)
112
0.631 (16.03)
0.622 (15.85)
0.009 (0.18)
0.50 (12.7)
5/8
0.756 (19.20)
0.749 (19.02)
0.007 (0.18)
0.62 (15.7)
3/4
0.881 (22.38)
0.872 (22.20)
0.009 (0.18)
0.75 (19.1)
1
1.132 (28.75)
1.123 (28.54)
0.008 (0.216)
0.91 (23.1)
11/4
1.382 (35.10)
1.373 (34.88)
0.008 (0.216)
1 0.97 (24.6)
11/2
1.633 (41.48)
1.623 (41.22)
0.010 (0.25)
1 .09 (27.1)
2
2.133 (54.18)
2.123 (53.92)
0.010 (0.25)
1.34 (34.0)
2112
2.633 (66.88)
2.623 (66.62)
0.010 (0.25)
1.47 (37.3)
3
3.133 (79.58)
3.123 (79.32)
0.010 (0.25)
1.66 (42.2)
31/2
3.633 (92.28)
3.623 (92.02)
0.010 (0.25)
1.91 (48.5)
4
4.133 (104.98) 14.123
(104.72) 10.010
(0.25) 1
2.16 (54.9)
5
5.133 (130.38)
5.123 (130.12) 10.010
(0.25) 1
2.66 (67.6)
6
6.133 (155.78) 16.123
(155.52) 10.010
(0.25) 1
3.09 (78.5)
The National Bureau of Standards Report BMS58, "Strength of Soft - Soldered Joints in Copper
Tubing," reporting on tests conducted with 3 /+ -inch tubing and fitting, says "When the
clearance is greater than 0.010 inch (0.25 mm), there is difficulty in filling the joint properly."
2. Depth of Solder Penetration drastically affects the breaking
load of the joint. When there is too great a soldering clearance,
there is no capillary flow to assure complete solder penetration
As shown in the chart below, the holding power of the 3 /4 -inch
joint is directly proportional to the depth of solder penetration.
For example: If you get only one -third penetration, you get
approximately one -third the strength needed to assure complete
satisfaction.
Chart 2 - Type K' /4" Tubing
I
i!
c
Solder penetration of one -third
the cup depth - breaking load,
approximately 2,100 lb. (955 kg)
2
m
02 6A 06 0.8 16 12
451 1181 IIS 4201 125f (30
DEPTH OF ONE INCt+1ES hnml
3W TO BE SURE OF PROPER TOLFRI
It is apparent that all of the scientific apparatus used to test tube
and fittings, according to the dimensions indicated in Chart 1, would
be impractical to use on the job. It is therefore essential that you
install tube and fittings manufactured by companies known to be
dedicated to the highest quality control standards. Should you
encounter a condition where there is difficulty in filling the joint
properly, NIBCO will analyze the trouble without charge. Just send
six inches of the tube, along with the fitting and our technicians will
provide you with an authoritative report.
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Solder penetration of the entire
cup depth - breaking load
approximately 7,000 lb. (3175 kg)
MEN
NAM
0
MR,
ME
-Ii.
�
MEMOMME
MMUMENE1
1910
SEE
il - 11111" 1 =-
rG1,C. . 4J.'114
02 6A 06 0.8 16 12
451 1181 IIS 4201 125f (30
DEPTH OF ONE INCt+1ES hnml
3W TO BE SURE OF PROPER TOLFRI
It is apparent that all of the scientific apparatus used to test tube
and fittings, according to the dimensions indicated in Chart 1, would
be impractical to use on the job. It is therefore essential that you
install tube and fittings manufactured by companies known to be
dedicated to the highest quality control standards. Should you
encounter a condition where there is difficulty in filling the joint
properly, NIBCO will analyze the trouble without charge. Just send
six inches of the tube, along with the fitting and our technicians will
provide you with an authoritative report.
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Solder penetration of the entire
cup depth - breaking load
approximately 7,000 lb. (3175 kg)
BRAZING
Copper Water
Tube Size
(In Inches)
1' 1
Brazing" Filler Required
Inches (mm)
Torch Tip
Drill Size o.
For Estimating Purposes
Acetylene Consumption Oxygen Pressure (Approx.) Acetylene Pressure (Approx.)
C.F.H. (C.M.H.) PSI (kPa) PSI (kPa)
1/4
0.25
(6.4)
54
15.9
(0.5)
4
(27)
4
(27)
3/8
038
(9.7)
54
15.9
(0.5)
4
(27)
4
(27)
112
0.50
(12.7)
51
24.8
03
5
34)
5
34
5/8
0.62
(15.7)
51
24.8
(03)
5
(34)
5
(34)
3/4
1.00
(25.0)
51
24.8
(0.7)
5
(34)
5
(34)
1
1.60
41.0)
48
31.6
(0.9)
6
41)
6
(41)
11/4
2.00
(51.0)
48
31.6
(0.9)
6
(41)
6
(41)
11/2
2.60
(66.0)
44
38.7
(1.1)
7
(48)
7
(48)
2
4.40
112.0)
40
60.0
1.7)
7
48)
7
48)
2112
5.90
(150.0)
40
60.0
(1.7)
7
(48)
7
(48)
3
7.90
(200.0)
35
70.0
(2.0)
7' /2
(52)
7
(52)
31/2
10.50
207.0)
35
70.0
(2.0)
7' /2
(52 )
712
52)
4
13.50
(343.0)
30
88.5
(2.5)
9
(62)
9
(62)
5
20.50
(521.0)
30
88.5
(2.5)
9
(62)
9
(62)
6
28.50
(724.0)
30
88.5
(2.5)
9
(62)
9
(62)
'Approximate consumption when brazing one cup of the fitting. Actual consumption depends on workmanship.
For filler sizes shown, one pound of filler alloy provides 1,068 inches (27.13 mm) of I /winch wire or 475 inches (12,065 mm) of 3 /32 -inch wire.
"/16-inch (1.59 mm) diameter wire; all other is 3 /32 -inch (2.38 mm) diameter.
SOLDER AND
Nom. Size Joint
(In Inches)
FLUX REQUIREMENTS
Solder Required, LB (kg)
General Use Drainage Use
1/4
0.097
-
3/8
0.159
-
1/2
0.261
-
5/8
0,389
-
3/4
0.548
-
1
0.856
-
1 1/4
1.115
1.2 0.5
1 112
1.480
1.4 (0.6)
2
2.380
1.5 (0.7)
2112
3.225
-
3
4.335
2.8 (1.3)
31/2
5.786
-
4
7.446
42 (1.9)
5
11.392
-
6
15.815
-
8
26.955
-
Solder requirements in this table are based on estimate of weight of solder used to prepare
100 solder joints of sizes shown.
Two (2) ounces (0.06 kg) of solder flux will be required for each pound (0.45 kg) of solder.
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. ^ ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Co pper Tube Fittings continued
olning matenals at or
above 593 °C Pressure - temperature ratings consistent with the materials and procedures employed.
[Note (7)]
GENERAL NOTE:
For extremely low working temperatures in the 0 °F to 2007 range, it is recommended that a joint material melting at or above 10007 be employed [see Note (5)].
NOTES:
(1) Standard water tube sizes per ASTM B 88
(2) ASTM B 32 Alloy Grade Sn50
(3) The Safe Drinking Water Act Amendment of 1986 prohibits the use of any solder having a lead content
in excess of 0.2% in potable water systems.
(4) ASTM B 32 Alloy Grade Sb5
(5) ASTM B 32 Alloy Grade E
(6) ASTM B 32 Alloy Grade HB
(7) These joining materials are defined as brazing alloys by the American Welding Society.
(8) The solderjoint exceeds the strength of Types K, L & M tube in drawn and annealed tempers.
(9) The solderjoint exceeds the strength of Types L & M tube in drawn temper and Type K tube in annealed temper.
(10) The solderjoint exceeds the strength of Type M tube in drawn temper and Types L & K in annealed temper.
(11) The solderjoint exceeds the strength of Type L tube in annealed temper.
Nominal Size Joint Nominal Size Joint
(In Inches) Temperature, °F ( °C)" I Pressure, PSI (BAR)" (In Inches) Temperature, °F ( °C) Pressure, PSI (BAR)
3/8, 1/2, 3/4, 1, 3/8, 1/2, 3/4, 1 73 (23) 200 (14)
1 1/4, 1 1/2, 2 100 (38) 175 (12) 140 (60) 160 (11)
ASME 876.26 180 (82) 100 (7)
200 (93) 80 (5)
U.S, customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
�, ,��
r
.,
„
P SI ( BAR
Maximum Gauge Working Pressure for Standard Water Tube Sizes [Note (1)]
, / though 1"
1 /4" through 2"
2 /2" through 4"
5" through 8"
10" to 12"
Saturated Steam
LB (kg)
Joining Material
Working Temperature
9 P
°F °C
PSI
BAR
PSI
BAR
PSI
BAR
PSI
BAR
PSI
BAR
All Sizes
Alloy Sn50
100
38
200
(14)
175
(12)
150
(10)
135
(9)
100
(6)
50 -50 Tin -Lead solder
150
66
150
(10)
125
(9)
100
(7)
90
(6)
70
(5)
[Notes (2), (3)]
200
93
100
(7)
90
6)
75
(5)
70
5)
50
3
15
250
121
85
6
75
5
50
3
45
3
40
3
Alloy Sb5
100
38
1090 "'
(75)
850 11
(59)
705 "'
(49)
660 m
(46)
340
(23)
95 -5 Tin - Antimony solder
150
66
625j
(43)
485 "
(34)
405 ('q
(28)
375 "
(26)
280
(19
[Note (4)]
200
93
505 ""
(35)
395
(27)
325 "
(32)
1 305 "
(21)
230
(16)
15
250
121
270
19
210
15
175
12 1
165
11
120
8
Alloy E
100
38
710
(49 )
555('
(38)
460
(32)
430 ")
(30)
320
22
150
66
475P
(33)
370 "°'
(26)
305 (
(21)
285
(20)
215
(15)
200
93
375
(26)
290
(20)
240""
(17)
225""
(16)
170
(12)
15
250
121
320
(22)
250
(17)
205
(14)
195
(13)
145
(9)
Alloy HB
100
38
1035 "'
(71)
805 0
(56)
670
(46)
625 "'
(43)
340
(23)
[Note (6)]
150
66
710j
F4 9)
555 "
(38)
460 ")
(32)
430 00 '
(30)
320
(22)
15
200
93
440 /n
(30)
345 nn
(24)
285 n„
(20)
2 65 "n
(18)
200
(14)
J"
250
121
430
(30)
335 ""
(23)
275 (
(19)
260 ""
(18)
195
(13)
olning matenals at or
above 593 °C Pressure - temperature ratings consistent with the materials and procedures employed.
[Note (7)]
GENERAL NOTE:
For extremely low working temperatures in the 0 °F to 2007 range, it is recommended that a joint material melting at or above 10007 be employed [see Note (5)].
NOTES:
(1) Standard water tube sizes per ASTM B 88
(2) ASTM B 32 Alloy Grade Sn50
(3) The Safe Drinking Water Act Amendment of 1986 prohibits the use of any solder having a lead content
in excess of 0.2% in potable water systems.
(4) ASTM B 32 Alloy Grade Sb5
(5) ASTM B 32 Alloy Grade E
(6) ASTM B 32 Alloy Grade HB
(7) These joining materials are defined as brazing alloys by the American Welding Society.
(8) The solderjoint exceeds the strength of Types K, L & M tube in drawn and annealed tempers.
(9) The solderjoint exceeds the strength of Types L & M tube in drawn temper and Type K tube in annealed temper.
(10) The solderjoint exceeds the strength of Type M tube in drawn temper and Types L & K in annealed temper.
(11) The solderjoint exceeds the strength of Type L tube in annealed temper.
Nominal Size Joint Nominal Size Joint
(In Inches) Temperature, °F ( °C)" I Pressure, PSI (BAR)" (In Inches) Temperature, °F ( °C) Pressure, PSI (BAR)
3/8, 1/2, 3/4, 1, 3/8, 1/2, 3/4, 1 73 (23) 200 (14)
1 1/4, 1 1/2, 2 100 (38) 175 (12) 140 (60) 160 (11)
ASME 876.26 180 (82) 100 (7)
200 (93) 80 (5)
U.S, customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
RATED WORKING
'
COPPER
Nominal Water
Water Temperature Range
Tube Size
(In Inches)
-20' to 1007
( -29° to 38 °C)
150 °F
(66 °C)
2001
(95 °C)
2507
(120 °C)
3007
(149 °C)
350 °F
(177 °C)
4007
°C)
(204
1/4
912
(62)
775
(53)
729
(50)
729 (50)
714
(49)
608
(42)
456
(31)
3/8
779
(54)
662
(46)
623
(43)
623 (43)
610
(42)
519
(36)
389
(27)
112
722
50)
613
42
577
(40)
577 (40)
565
(39)
481
33)
361
(25)
5/8
631
(43)
537
(37)
505
(35)
505 (35)
495
(34)
421
(29)
316
(21)
3/4
582
(40)
495
(34)
466
(32)
466 (32)
456
(31)
388
(27)
291
(20)
1
494
34)
420
(29)
395
(27)
395 27)
387
(26)
330
23)
247
17)
11/4
439
(30)
373
(26)
351
(24)
351 (24)
344
(23)
293
(20)
219
(15)
11/2
408
(28)
347
(24)
327
(23)
327 (23)
320
(22)
272
(19)
204
(1 4)
2
364
25)
309
21)
291
(20)
291 20)
285
(20)
242
17)
182
13
2112
336
(23)
285
(20)
269
(19)
269 (19)
263
(18)
224
(15)
168
(12)
3
317
(22)
270
(19)
254
(17)
254 (17)
248
(17)
211
(15)
159
(11)
31/2
304
(21 )
258
(18 )
243
(17)
243 (17 )
238
(16)
202
14)
152
(10
4
293
(20)
249
(17)
235
(16)
235 (16)
230
(16)
196
(13)
147
(10)
5
269
(19)
229
(16) 1
215
(15)
1 215 (15)
211
(15)
179
(12)
135
(9)
6
251
(17)
213
(15)
201
(14)
1
196
(14)
167
(12)
125
(8)
8
270
(19)
230
(16)
216
(15)
1 216 (15)
212
(15)
180
(12)
135
(9)
fhe fitting pressure rating applies to the largest opening of the fitting.
Nominal Size Joint
(In Inches)
112, 3/4,1,1 1/4,
1112, 2, 21 12,
3, 4, 5, 6, 8
(also 10" for
Class 125)
Temperature t
( ) "
0 -150 (0 -61
175 (79)
200 (93)
250
275
300
Class 150" `
225 (15)
220 (15)
210 (15)
205 (14)
195 (13)
190 (13)
180 (12)
165 11)
150 (10)
406 (208)
"MSS SP -106
a ASTM 8584, UNS C83800 and UNS C84400
ASTM B62, UNS C83600 and ASTM 8584, UNS C83600
Class 125" e
105 (7)
100 (7)
95 (7)
90 (6)
90 (6)
85 (6)
85 (6)
75 (5)
70 (5)
Pressure (PSI)
Class 150
210 (14)
205 (14)
195 (13)
190 (13)
180 (12)
175 (12)
170 (12)
150 (10)
140 (9)
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART,IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
17
Copper
Water Tube
The mechanics of making both the solder joint and the brazing joint are comparatively similar. Complete instructions
on proper techniques of both of these joining methods are outlined in this catalog on pages 85 -97.
A very important consideration in Copper Piping is the selection of the proper bonding medium. As a general rule, the working
temperature of the installation is a more important consideration than the working pressures. If the working temperature is not over
250 °F (121 °C), either 50 -50 %* or 95 -5% solder can be used successfully. However, if the temperature exceeds 2507 (1 21 °C), a low
temperature brazing alloy should be used, with a melting temperature somewhat in excess of 1000 °F (538 °C).
According to BMS report No. 58, joints made with tin or tin -alloy solders should not be subject continuously to temperatures above
250 *F (121 °C). A number of brazing alloys are available and a careful study should be made in every case to determine the proper
alloy for the particular application.
"The Safe Drinking Water Act Amendment of 1986 prohibits the use in potable water systems of any solder having a lead content in excess of 0.2 %.
DIMENSIONAL
Nominal
Water Tube
Size (In Inches)
DATA SOLDER 1 1
Solder Joint Fittings - Tolerances
Male End (Fitting Connector) Female End (Solder Cup)
Diameter Diameter
Min. Max. Min. Max.
Inch (mm) Inch (mm) Inch (mm) Inch (mm)
Solder Joint Fittings
Copper Alloy - Pressure' Z
Fitting End Length Solder Cup Length
Min. Min.
Inch (mm) Inch (mm)
Solder Joint Fittings
Copper Alloy - Drainage' '
Fitting End Length Solder Cup Length
Min. Min.
Inch (mm) Inch (mm)
1/8
0.248
(6.30)
0.251
(6.38)
0.252
(6.40)
0.256
(6.50)
0.31
(7.9)
0.25
(6.4)
N/A
N/A
N/A
N/A
1/4
0.373
(9.47)
0.376
(9.55)
0.377
(9.58)
0.381
(9.68)
0.38
(9.7)
0.31
(7.9)
N/A
N/A
N/A
N/A
3/8
0.497
(12.62)
0.501
(12.73)
0.502
(12.75)
0.506
(12.85)
0.44
(11.2)
0.38
(9.7)
N/A
N/A
N/A
N/A
112
0.622
(15.80)
0.626
(15.90)
0.627
(15.93)
0.631
(16.03)
0.56
(14.2)
0.50
(12.7)
N/A
N/A
N/A
N/A
5/8
0.747
(18.97)
0.751
(19.08)
0.752
(19.10)
0.756
(19.20)
0.69
(17.5)
0.62
(15.7)
N/A
N/A
N/A
N/A
3/4
0.872
(22.15)
0.876
(22.25)
0.877
(22.28)
0.881
(22.38)
0.81
(20.6)
0.75
(19.1)
N/A
N/A
N/A
N/A
1
1.122
(28.50)
1.127
(28.63)
1.128
(28.65)
1.132
(28.75)
0.97
(24.6)
0.91
(23.1)
N/A
N/A
N/A
N/A
11/4
1.372
(34.85)
1.377
(34.98)
1.378
(35.00)
1.382
(35.10)
1.03
(26.2)
0.97
(24.6)
0.56
(14.2)
0.50
(12.7)
1112
1.621
(41.17)
1.627
(41.33)
1.628
(41.35)
1.633
(41.48)
1.16
(29.5)
1.09
(27.7)
0.62
(15.7)
0.56
(14.2)
2
2.121
(53.87)
2.127
(54.03)
2.128
(54.05)
2.133
(54.18)
1.41
(35.8)
1.34
(34.0)
0.69
(17.5)
0.62
(15.7)
2112
2.621
(66.57)
2.627
(66.73)
2.628
(66.75)
2.633
(66.88)
1.53
(38.9)
1.47
(37.3)
N/A
N/A
N/A
N/A
3
3.121
(79.27)
3.127
(79.43)
3.128
(79.45)
3.133
(79.58)
1.72
(43.7)
1.66
(42.2)
0.81
(20.6)
0 .75
(19.1)
31/2
3.621
(91.97)
3.627
(92.13)
3.628
(92.15)
3.633
(92.28)
1.97
(50.0)
1.91
(48.5)
N/A
N/A
N/A
N/A
4
4.121
(104.67)
4.127
(104.83)
4.128
(104.85)
4.133
(104.98)
2.22
(56.4)
2.16
(54.9)
1.06
(26.9)
1.00
(25.4)
5
5.121
(130.07)
5.127
(130.23)
5.128
(130.25)
5.133
(130.38)
2.72
(69.1)
2.66
(67.6)
1.31
(33.3)
1.25
(31.8)
6
6.121
(155.47)
6.127
(155.63)
6.128
(155.65)
3.133
(79.58)
3.22
(81.8)
3.09
(78.5)
1.62
(41.1)
1.50
(38.1)
8
8.119
(206.22)
8.127
(206.43)
8.128
(206.45)
8.133
(206.58)
4.09
(103.9)
3.97
(100.8)
2.12
(53.8)
2.00
(50.8)
10
10.119 (257.02)
10.127
(257.23)
10.128 (257.25)
10.133
(257.38)
4.12
(104.6)
4.00
(101.6)
N/A
N/A
N/A
N/A
12
12.119
(307.82)
12.127
(308.03)
12.128 (308.05)
12.133
(308.18)
4.62
(117.3)
4.50
(114.3)
N/A
N/A
N/A
N/A
'As shown Standard ASME B16.18
' As shown Standard ASME 816.22
'As shown Standard ASME B16.23
'As shown Standard ASME 816.29
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
DIMENSIONAL
Nominal
Water Tube
Size (In Inches)
DATA •A 1
Male End (Fitting Connector) Diameter
Min. Max.
Inch (mm) Inch (mm)
Inch
Female End (Brazing Cup) Diameter
Min. Max.
(mm) Inch (mm)
Fitting End
Length
Min.
Inch (mm)
Solder Cup
Length
Min.
Inch (mm)
1/4
0.373
(9.47)
0.376
(9.55)
0.377
(9.58)
0.381
(9.68)
0.23
(5.8)
0.17
(4.3)
3/8
0.497
(12.62)
0.501
(12.73)
0.502
(12.75)
0.506
(12.85)
0.26
(6.6)
0.20
(5.1)
112
0.622
(15.80)
0.626
(15.90)
0.627
(15.93)
0.631
(16.03)
0.28
(7.1)
0.22
(5.6)
5/8
0.747
(18.97)
0.751
(19.08)
0.752
(19.10)
0.756
(19.20)
N/A
N/A
N/A
N/A
3/4
0.872
(22.15)
0.876
(22.25)
0.877
(22.28)
0.881
(22.38)
0.31
(7.9)
0.25
(6.4)
1
1.122
(28.50)
1.127
(28.63)
1.128
(28.65)
1.132
(28.75)
0.34
(8.6)
0.28
(7.1)
11/4
1.372
(34.85)
1.377
(34.98)
1.378
(35.00)
1.382
(35.10)
0.37
(9.4)
0.31
(7.9)
1112
1.621
(41.17)
1.627
(41.33)
1.628
(41.35)
1.633
(41.48)
0.40
(10.2)
0.34
(8.6)
2
2.121
(5187)
2.127
(54.03)
2.128
(54.05)
2.133
(54.18)
0.47
(11.9)
0.40
(10.2)
2112
2.621
(66.57)
2.627
(66.73)
2.628
(66.75)
2.633
(66.88)
0.53
(13.5)
0.47
(11.9)
3
3.121
(79.27)
3.127
(79.43)
3.128
(79.45)
3.133
(79.58)
0.59
(15.0)
0.53
(13.5)
31/2
3.621
(91.97)
3.627
(92.13)
3.628
(92.15)
3.633
(92.28)
0.65
(16.5)
0.59
(15.0)
4
4.121
(104.67)
4.127
(104.83)
4.128
(104.85)
4.133
(104.98)
0.72
(18.3)
0.64
(16.3)
5
5.121
(130.07)
5.127
(130.23)
5.128
(130.25)
5.133
(130.38)
0.81
(20.6)
0.73
(18.5)
6
6.121
(155.47)
6.127
(155.63)
6.128
(155.65)
3.133
(79.58)
0.94
(23.9)
0.83
(21.1)
8
8.119
(206.22)
8.127
(206.43)
8.128
(206.45)
8.133
(206.58)
1.28
(32.5)
1.17
(29.7)
10
10.119
(257.02)
10.127
(257.23)
10.128
(257.25)
10.133
(257.38)
N/A
N/A
N/A
N/A
12
12.119
(307.82)
12.127
(308.03)
12.128
(308.05) 1
12.133
(308.18)
N/A
N/A
N/A
N/A
' In accordance with MS SP -73
U.S. customary units in this document are the standard; the metric units are provided for
reference only The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. ^ IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Copper Water Tube continued
DIMENSIONAL
Nominal
Water Tube
Size (In Inches)
DATA COPPER
Outside
Diameter
Inch (mm)
Tolerances
(Hard Drawn Only)
Tubing OD
Min. Max.
Inch (mm) Inch (mm)
TYPE "K"
Hard Drawn:
Soft Annealed:
Usage:
20 -ft. (6.1m) Straight Lengths
20 -ft. (6.1 m) Straight Lengths, or 40 -ft. (12.2m) and
60 -ft. (18.3m) Length Coils (to and including size 1 1/2)
For underground service and general purpose plumbing and
heating installations under severe conditions.
Nominal Wall
Thickness
Inch (mm)
Weight
Per Foot
Lb (kg)
Hard Drawn
Bursting Safe Working
Pressure" Pressure'
psi (bars) psi (bars)
Soft Annealed
Bursting Safe Working
Pressure" Pressure`
psi (bars) psi (bars)
1/4
0.375
(9.53)
0.373
(9.47)
0.376
(9.55)
0.035
(0.89)
0.145
(0.07)
N/A N/A
1612
(111)
N/A
N/A
913
(63)
3/8
0.500
(12.70)
0.497
(12.62)
0.501
(12.73)
0.049
(1.24)
0.269
(0.12)
N/A N/A
1675
(115)
N/A
N/A
960
(66)
112
0.625
(15.88)
0.622
(15.80)
0.626
(15.90)
0.049
(1.24)
0.344
(0.16)
9840 (678)
1337
(92)
4535
(313)
758
(52)
5/8
0.750
(19.05)
0.747
(18.97)
0.751
(19.08)
0.049
(1.24)
0.418
(0.19)
N/A N/A
1104
(76)
N/A
N/A
626
(43)
3/4
0.875
(22.23)
0.872
(22.15)
0.876
(22.25)
0.065
(1.65)
0.641
(0.29)
9300 (641)
1278
(88)
4200
(290)
724
(50)
1
1.125
(28.58)
1.122
(28.50)
1.127
(28.63)
0.065
(1.65)
0.839
(0.38)
7200 (496)
982
(68)
3415
(235)
557
(38)
11/4
1.375
(34.93)
1.372
(34.85)
1.377
(34.98)
0.065
(1.65)
1.040
(0.47)
5525 (381)
797
(55)
2800
(193)
452
(31)
1112
1.625
(41.28)
1.621
(41.17)
1.627
(41.33)
0.072
(1.83)
1.360
(0.62)
5000 (345)
742
(51)
2600
(179)
420
(29)
2
2.125
(53.98)
2.121
(53.87)
2.127
(54.03)
0.083
(2.11)
2.060
(0.93)
3915 (270)
652
(45)
2235
(154)
370
(26)
2112
2.625
(66.68)
2.621
(66.57)
2.627
(66.73)
0.095
(2.41)
2.930
(1.33)
3575 (246)
597
(41)
N/A
N/A
338
(23)
3
3.125
(79.38)
3.121
(79.27)
3.127
(79.43)
0.109
(2.77)
4.000
(1.81)
3450 (238)
578
(40)
N/A
N/A
328
(23)
31/2
3.625
(92.08)
3.621
(91.97)
3.627
(92.13)
0.120
(3.05)
5.120
(2.32)
N/A N/A
549
(38)
N/A
N/A
311
(21)
4
4.125
(104.78)
4.121
(104.67)
4.127
(104.83)
0.134
(3.40)
6.510
(2.95)
3415 (235)
540
(37)
N/A
N/A
306
(21)
5
5.125
(130.18)
5.121
(130.07)
5.127
(130.23)
0.160
(4.06)
9.670
(4.39)
3585 (247)
517
(36)
N/A
N/A
293
(20)
6
6.125
(155.58)
6.121
(155.47)
6.127
(155.63)
0.192
(4.88)
13.900
(6.30)
3425 (236)
520
(36)
N/A
N/A
295
(20)
8
8.125
(206.38)
8.119
(206.22)
8.127
(206.43)
0.271
(6.88)
25.900 (11.75)
3635 (251)
553
(38)
N/A
N/A
314
(22)
10
10.125
(257.18)
10.119
(257.02)
10.127
(257.23)
0.338
(8.59)
40.300 (18.28)
N/A N/A
553
(38)
N/A
N/A
314
(22)
12
12.125 (307.98)
12.119
(307.82)
12.127
(308.03)
0.405
(10.29)
57.800 (26.22)
N/A N/A
555
(38)
N/A
N/A 1
314
(22)
Note: Information and data contained in these charts, as taken from ASTM Specifications B 88.
Rated internal pressure for copper water tube based on the strength of the tube alone and
applicable to systems using suitable mechanicaljoints.
"Based on actual laboratory test data provided by Copper Development Association, Inc.
° Based upon 1501 (65.6 °C) with an allowable stress of 9500 psi (668 kPa).
Based upon 150 °F (65.6 °C) with an allowable stress of 5100 psi (359 kPa).
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
DIMENSIONAL
Nominal
Water Tube
Size (In Inches)
DATA - COPPER
Outside
Diameter
Inch (mm)
Inch
WATER TUBE - TYPE
Tolerances
(Hard Drawn Only)
Tubing OD
Min. Max.
(mm) Inch (mm)
"L"
TYPE 1"
Hard Drawn:
Soft Annealed:
Usage:
20 -ft. (6.1m) Straight Lengths
20 -ft. (6.1m) Straight Lengths, or 40 -ft. (12.2m) and
60 -ft. (18.3m) Length Coils (to and including size 1 1/2)
For general purpose plumbing and heating conditions.
Nominal Wall
Thickness
Inch (mm)
Weight
Per Foot
Lb (kg)
Hard Drawn
Bursting Safe Working
Pressure" Pressure'
psi (bars) psi p (bars)
Soft Annealed
Bursting Safe Working
Pressure" Pressure`
psi (bars) p (bars)
1/4
0.375
(9.53)
0.373
(9.47)
0.376
(9.55)
0.030
(0.76)
0.126
(0.06)
N/A
N/A
1367
(94)
N/A
N/A
775
(53)
3/8
0.500
(12.70)
0.497
(12.62)
0.501
(12.73)
0.035
(0.89)
0.198
(0.09)
N/A
N/A
1168
(81)
N/A
N/A
662
(46)
112
0.625
(15.88)
0.622
(15.80)
0.626
(15.90)
0.040
(1.02)
0.285
(0.13)
7765
(535)
1082
(75)
3885
(268)
613
(42)
5/8
0.750
(19.05)
0.747
(18.97)
0.751
(19.08)
0.042
(1.07)
0.362
(0.16)
N/A
N/A
947
(65)
N/A
N/A
537
(3�
3/4
0.875
(22.23)
0.872
(22.15)
0.876
(22.25)
0.045
(1.14)
0.455
(0.21)
5900
(407)
873
(60)
2935
(202)
495
(34)
1
1.125
(28.58)
1.122
(28.50)
1.127
(28.63)
0.050
(1.27)
0.655
(0.30)
5115
(353)
741
(51)
2650
(183)
420
(29)
11/4
1.375
(34.93)
1.372
(34.85)
1.377
(34.98)
0.055
(1.40)
0.884
(0.40)
4550
(314)
658
(45)
2400
(165)
373
(26)
1112
1.625
(41.28)
1.621
(41.17)
1.627
(41.33)
0.060
(1.52)
1.140
(0.52)
4100
(283)
613
(42)
2200
(152)
347
(24)
2
2.125
(53.98)
2.121
(53.87)
2.127
(54.03)
0.070
(1.78)
1.750
(0.79)
3365
(232)
545
(38)
1910
(132)
309
(21)
2112
2.625
(66.68)
2.621
(66.57)
2.627
(66.73)
0.080
(2.03)
2.480
(1.12)
3215
(222)
504
(35)
N/A
N/A
285
(20)
3
3.125
(79.38)
3.121
(79.27)
3.127
(79.43)
0.090
(2.29)
3.330
(1.51)
2865
(198)
476
(33)
N/A
WA
270
(19)
31/2
3.625
(92.08)
3.621
(91.97)
3.627
(92.13)
0.100
(2.54)
4.290
(1.95)
N/A
N/A
455
(31)
N/A
N/A
258
(18)
4
4.125
(104.78)
4.121
(104.67)
4.127
(104,83)
0.110
(2.79)
5.380
(2.44)
2865
(198)
440
(30)
N/A
N/A
249
(17)
5
5.125
(130.18)
5.121
(130.07)
5.127
(130.23)
0.125
(3.18)
7.610
(3.45)
2985
(206)
404
(28)
N/A
N/A
229
(16)
6
6.125
(155.58)
6.121
(155.47)
6.127
(155.63)
0.140
(3.56)
10.200
(4.63)
2690
(185)
376
(26)
N/A
N/A
213
(15)
8
8.125
(206.38)
8.119
(206.22)
8.127
(206.43)
0.200
(5.08)
19.290
(8.75)
2650
(183)
406
(28)
N/A
N/A
230
(16)
10
10.125
(257.18)
10.119
(257.02)
10.127
(257.23)
0.250
(6.35)
30.100
(13.65)
N/A
N/A
407
(28)
N/A
N/A
231
(16)
12
12.125
(307.98)
12.119 (307.82)
12.127
(308.03)
0.280
(7.11) 140.400
(18.33)
N/A
N/A
380
(26)
N/A
N/A
215
(15)
Note: Information and data contained in these charts, as taken from ASTM Specifications B 88.
Rated internal pressure for copper water tube based on the strength of the tube alone and
applicable to systems using suitable mechanicaljoints.
"Based on actual laboratory test data provided by Copper Development Association, Inc.
° Based upon 150 °F (65.6 °C) with an allowable stress of 9500 psi (668 kPa).
Based upon 150 °F (65.6 °C) with an allowable stress of 5100 psi (359 kPa).
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST - ELKHART, IN 46516 -4740 • USA • PH: 1,800,234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Copper Water Tubecontinued
DIMENSIONAL
Nominal
Water Tube
Size (In Inches)
DATA COPPER
Outside
Diameter
Inch (mm)
Inch
Tolerances
(Hard Drawn Only)
Tubing OD
Min. Max.
(mm) Inch (mm)
TYPE "M" Hard Drawn Only: 20 -ft. (6.1m) Straight Lengths
Usage: For general purpose plumbing, heating and
drainage installations.
Nominal Wall
Thickness
Inch (mm)
Weight
Per foot
Lb (kg)
g)
Hard Drawn
Bursting Safe Working
Pressure" Pressure'
psi
p (bars) psi (bars)
1/4
0.375
(9.53)
0.373
(9.47)
0.376
(9.55)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
3/8
0.500
(12.70)
0.497
(12.62)
0.501
(12.73)
0.025
(0.64)
0.145
(0.07)
N/A
N/A
855
(59)
112
0.625
(15.88)
0.622
(15.80)
0.626
(15.90)
0.028
(0.71)
0.204
(0.09)
6135
(423)
741
(51)
5/8
0.750
(19.05)
0.747
(18.97)
0.751
(19.08)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
3/4
0.875
(22.23)
0.872
(22.15)
0.876
(22.25)
0.032
(0.81)
0.328
(0.15)
4717
(325)
611
(42)
1
1.125
(28.58)
1.122
(28.50)
1.127
(28.63)
0.035
(0.89)
0.465
(0.21)
3865
(266)
506
(35)
11/4
1.375
(34.93)
1.372
(34.85)
1.377
(34.98)
0.042
(1.07)
0.682
(0.31)
3875
(267)
507
(35)
1112
1.625
(41.28)
1.621
(41.17)
1.627
(41.33)
0.049
(1.24)
0.940
(0.43)
3550
(245)
497
(34)
2
2.125
(53.98)
2.121
(53.87)
2.127
(54.03)
0.058
(1.47)
1.460
(0.66)
2935
(202)
448
(31)
2112
2.625
(66.68)
2.621
(66.57)
2.627
(66.73)
0.065
(1.65)
2.030
(0.92)
2800
(193)
411
(28)
3
3.125
(79.38)
3.121
(79.27)
3.127
(79.43)
0.072
(1.83)
2.680
(1.22)
2665
(184)
380
(26)
31/2
3.625
(92.08)
3.621
(91.97)
3.627
(92.13)
0.083
(2.11)
3.580
(1.62)
N/A
N/A
378
(26)
4
4.125
(104.78)
4.121
(104.67)
4.127
(104.83)
0.095
(2.41)
4.660
(2.11)
2215
(153)
377
(26)
5
5.125
(130.18)
5.121
(130.07)
5.127
(130.23)
0.109
(2.77)
6.660
(3.02)
2490
(172)
349
(24)
6
6.125
(155.58)
6.121
(155.47)
6.127
(155.63)
0.122
(3.10)
8.920
(4.05)
2000
(138)
328
(23)
8
8.125
(206.38)
8.119
(206.22)
8.127
(206.43)
0.170
(4.32)
16.500
(7.48)
2285
(158)
344
(24)
10
10125
(257.18)
10.119
(257.02)
10.127
(257.23)
0.212
(5.38)
25.600
(11.61)
N/A
N/A
344
(24)
12
12.125
(307.98)
12.119
(307.82)
12.127
(308.03)
0.254
(6.45)
36.700
(16.65)
N/A
N/A
345
(24)
Note: Information and data contained in these charts, as taken from ASTM Specifications B 88.
Rated internal pressure for copper water tube based on the strength of the tube alone and
applicable to systems using suitable mechanicaljoints.
"Based on actual laboratory test data provided by Copper Development Association, Inc.
° Based upon 150 °F (65.6 °C) with an allowable stress of 9500 psi (668 kPa).
U.S. customary units in this document are the standard; the metric units are provided for
reference only The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
TYPE "DWV" Hard Drawn Only: 20 -ft. (6.1m) Straight Lengths
Usage: For drain, waste, vent and other non - pressure applications.
Nominal
Water Tube
Size (In Inches)
Outside
Diameter
Inch (mm)
Tolerances
(Hard Drawn Only)
Tubing OD
Min. Max.
Inch (mm) Inch (mm)
Nominal Wall
Thickness
Inch (mm)
Weight
Per Foot
Lb (kg)
Hard Drawn
Bursting
Pressure'
psi (bars)
1/4
0.375
(9.53)
0.373
(9.47)
0.376
(9.55)
N/A
N/A
N/A
N/A
N/A
N/A
3/8
0.500
(12.70)
0.497
(12.62)
0.501
(12.73)
N/A
N/A
N/A
N/A
N/A
N/A
112
0.625
(15.88)
0.622
(15.80)
0.626
(15.90)
N/A
N/A
N/A
N/A
N/A
N/A
5/8
0.750
(19.05)
0.747
(18.97)
0.751
(19.08)
N/A
N/A
N/A
N/A
N/A
N/A
3/4
0.875
(22.23)
0.872
(22.15)
0.876
(22.25)
N/A
N/A
N/A
N/A
N/A
N/A
1
1.125
(28.58)
1.122
(28.50)
1.127
(28.63)
N/A
N/A
N/A
N/A
N/A
N/A
11/4
1.375
(34.93)
1.372
(34.85)
1.377
(34.98)
0.040
(1.02)
0.650
(0.29)
N/A
N/A
1112
1.625
(41.28)
1.621
(41.17)
1.627
(41.33)
0.042
(1.07)
0.809
(0.37)
440
(30)
2
2.125
(53.98)
2.121
(53.87)
2.127
(54.03)
0.042
(1.07)
1.070
(0.49)
326
(22)
2112
2.625
(66.68)
2.621
(66.57)
2.627
(66.73)
N/A
N/A
N/A
N/A
N/A
N/A
3
3.125
(79.38)
3.121
(79.27)
3.127
(79.43)
0.045
(1.14)
1.690
(0.77)
239
(16)
31/2
3.625
(92.08)
3.621
(91.97)
3.627
(92.13)
N/A
N/A
N/A
N/A
N/A
N/A
4
4.125
(104.78)
4.121
(104.67)
4.127
(104.83)
0.058
(1.47)
2.870
(1.30)
225
(16)
5
5.125
(130.18)
5.121
(130.07)
5.127
(130.23)
0.072
(1.83)
4.430
(2.01)
227
(16)
6
6.125
(155.58)
6.121
(155.47)
6.127
(155.63)
0.083
(2.11)
6.100
(2.77)
223
(15)
8
8.125
(206.38)
8.119
(206.22)
8.127
(206.43)
0.109
N/A
10.600
(4.81)
219
(15)
10
10.125
(257.18)
10.119
(257.02)
10.127
(257.23)
N/A
N/A
N/A
N/A
N/A
N/A
12
12.125
(307.98)
12.119
(307.82)
12.127
(308.03)
N/A
N/A
N/A
N/A
N/A
N/A
Note: Information and data contained in these charts, as taken from ASTM Specifications B 88.
Rated internal pressure for copper water tube based on the strength of the tube alone and
applicable to systems using suitable mechanicaljoints.
"Based on actual laboratory test data provided by Copper Development Association. Inc.
e Based upon 150 °F (65.6 °C) with an allowable stress of 9500 psi (668 kPa).
`Based upon 150 °F (65.6 °C) with an allowable stress of 5100 psi (359 kPa).
U.S. customary units in this document are the standard; the metric units are provided for
reference only The values stated in each system are not exact equivalents.
DWV Tube is for sanitary drainage
applications. The tubing wall is thinner than
Type "M" - making it both lighter and less
expensive. Research indicates that DWV tube
has a service life of approximately 100 years -
considerably longer than any building in which
it might be installed.
The advantages of copper systems are
augmented in DWV installations. Its light
weight makes handling and transportation
easier - only 0.34 lb. (0.15 kg) for a 20 ft. (61
m) length of size 3. Its thinner wall allows
faster soldering.
These advantages offer an economical option
without sacrificing stability or longevity for
both contractor and the home owner. Further
information will be furnished on request from
NIBCO's Technical Services Department, at
1- 888 - 446 -4226
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455
Copper Water Tubecontinued
Under normal conditions, the physical properties of copper tubes, when produced by responsible manufacturers are perfectly adapted
for the conveyance of hot and cold water, steam, oil, gas, and air. Copper tubes will stand up under ordinary conditions, but the user is
specifically cautioned against laying underground tube in cinderfill, especially if the ground is apt to be wet. Due to the sulphur
compounds in the cinders, a condition of this kind may corrode the outside of the tubes. This may be overcome either by wrapping the
tube with canvas and asphaltum or by surrounding the tube with a bed of clean sand mixed with lime, or with limestone or broken
plaster. When conditions are doubtful, it is advisable to consult the Copper Development Association, or the tube manufacturer.
Annealed copper tubes are generally recommended for underground use. '/2" annealed copper tubes have been frozen as many as six
times before finally bursting, eight times for 1" size, and eleven times for 2" size. Hard drawn copper tubes, however, burst during the
first freezing the same as iron pipe. (Condensed from Copper Tube Handbook.)
COMPARATIVE
DATA
- COPPER
WATER
TUBE AND
IRON
PIPES
BTUs to Raise 100 °F /38 °C
Nominal
"A
"B"
"C"
"D"
"E"
7"
"G
"H"
Water
New Pipe
Inside
Outside
Weight
Volume
Water
Pipe
Heat
Loss
Flow
Tube Size
Diameter
Diameter
(In Inches)
Inch
(mm)
Inch
(mm)
Lb
(Kg)
Gal /10ft.
L /3.05m
BTU
kJ
BTU
kJ
BTU
kJ
GPM
LPM
3/8
Coper
.430
(10.92)
0.500
(12.70)
0.198
(0.090)
0.0754
(0.2854)
62.89
(66.4)
18.61
(19.6)
No Data
No Data
1.873
(7.089)
Iron
.493
(12.52)
0.675
(17.15)
0.567
(0.257)
0.0992
(0.3755)
82.66
(87.2)
62.37
(65.8)
No Data
No Data
2.464
(9.326)
112
Coper
.545
(13.84)
0.625
(15.88)
0,285
(0.129)
0.1212
(0.4587)
101.20
(106.8)
26.70
(28.2)
0.34
(0.36)
3.565
(13.494)
Iron
.622
(15.80)
0.840
(21.34)
0.850
(0.386)
0.1578
(0.5973)
131.60
(138.8)
93.50
(98.6)
5.94
(6.27)
4.585
(17.354)
3/4
Coper
.785
(19.94)
0.875
(22.23)
0.455
(0.207)
0.2514
(0.9515)
209.60
(221.1)
42.67
(45.0)
0.41
(0.44)
9.599
(36.332)
Iron
.824
(20.93)
1.050
(26.67)
1.130
(0.513)
0.2770
(1.0484)
230.10
(242.8)
124.30
(131.1)
7.16
(7.55)
9.720
(36.790)
1
Coper
1.025
(26.04)
1.125
(28.58)
0.655
(0.297)
0.4287
(1.6226)
357.30
(317.0)
61.38
(64.8)
0.50
(0.53)
19.80
(74.94)
Iron
1.049
(26.64)
1.315
(33.40)
1.678
(0.762)
0.4490
(1.6995)
374.30
(394.9)
184.58
(194.7)
8.62
(9.09)
18.53
(70.14)
11/4
Coper
1.265
(32.13)
1.375
(34.93)
0.884
(0.401)
0.6529
(2.4712)
544.30
(574.3)
82.91
(81.5)
0.62
(0.65)
35.05
(132.66)
Iron
1.380
(35.05)
1.660
(42.16)
2.270
(1.031)
0.7770
(2.9409)
647.70
(683.4)
249.70
(263.4)
10.65
(11.24)
38.56
(145.95)
1112
Coper
1.505
(38.23)
1.625
(41.28)
1.140
(0.518)
0.9241
(3.4977)
770.40
(812.8)
107.16
(113.1)
0.69
(0.73)
56,16
(212.57)
Iron
1.610
(40.89)
1.900
(48.26)
2.720
(1.235)
1.0580
(4.0045)
881.60
(930.1)
298.10
(314.5)
11.97
(12.63)
58.20
(220.29)
2
Coper
1.985
(50.42)
2.125
(53.98)
1.750
(0.795)
1.6080
(6.0863)
1340.00
(1413.8)
164.50
(173.6)
0.84
(0.89)
119.10
(450.79)
Iran
2.067
(52.50)
2.375
(60.33)
3.650
(1.657)
1.7430
(6.5973)
1453.00
(1533.0)
401.50
(423.6)
14.61
(15.41)
113.50
(429.60)
2112
Coper
2.465
(62.61)
2.625
(66.68)
2.480
(1.126)
2.4790
(9.3830)
2066.00
(2119.7)
233.00
(245.8)
1.01
(1.07)
214.30
(811.13)
Iron
2.469
(62.71)
2.875
(73.03)
5.790
(2.629)
2.4870
(9.4133)
2073.00
(2187.1)
636.90
(672.0)
17.42
(18.38)
182.50
(690.76)
3
Coper
2.945
(74.80)
3.125
(79.38)
3.330
(1.512)
3.5390
(13.3951)
2945.00
(3107.1)
313.20
(330.4)
1.13
(1.19)
347.40
(1314.91)
Iron
3.068
(77.93)
3.5
(88.90)
7.58
(3.441)
3.8400
(14.5344)
3201.00
(3377.2)
832.70
(878.5)
20.63
(21.77)
326.00
(1233.91)
4
Coper
3.905
(99.19)
4.125
(104.78)
5.380
(2.443)
6.2220
(23.5503)
5186.00
(5471.5)
505.72
(533.6)
1.50
(1.58)
747.10
(2821.77)
Iron
4.026
(102.26)
4.5
(114.30)
10.79
(4.899) 1
6.6130
(25.0302)
5513.00
(5816.5)
1186.90
(1252.2)
26.00
(27.43) 1
673.80
(2550.33)
COLUMN A: The copper tube is Type L Standard, meeting the requirements of ASTM
Specification B 88. The iron pipe is standard weight, schedule 40, bare pipe, except as
to Column I where new galvanized pipe is referred to.
COLUMN B: From manufacturers' specifications. Slight variations can be noted between
specifications of different manufacturers, but these figures are representative.
COLUMN C: From manufacturers' specifications with the same considerations as noted
for Column B.
COLUMN D: From manufacturers' specifications.
COLUMN E: Cubic contents of 10 linear feet/3.05 linear metres of tube and have been
calculated from dimeters given in Column B, by the formula for the contents of a cylinder.
COLUMN F: This column has been calculated from Column E and shows the number of
BTUs (kilojoules) required to heat the water content only of 10 feet (3.05 metres) of the
given tube and pipe 100 °F (38 °C). It requires 833.6 BTUs (879.5 kJ) to heat 1 gallon
(3.875 litres) of water 1007 (38 °C).
COLUMN G: These figures are calculated from Column D and show the number of BTUs
(kJ) required to raise the temperature of 10 feet (3.05 metres) of empty tube and pipe
1007 (38 °C). Due to difference in the specific heat of the materials, it requires 9.4 BTUs
(9.9 IQ to raise 1 pound (0.454 kilograms) of copper 1007 (38 °C) and 11.0 BTUs (11.6
Q to raise 1 pound (0.454 kilograms) of iron 1007 (38 °C).
COLUMN H: This column shows the heat emission from 10 feet (3.05 metres) of the given
tube and pipe placed horizontally. The column in terms of BTUs lost per hour (kilojoules
lost per hour) for each degree of difference in temperature between the pipe and the
surrounding air. The figures for iron are taken from experimental data obtained at the
Mellon Institute. Figures for copper have been calculated with reference to those for iron
on the basis of the known ratio of heat emission between the two materials.
COLUMN I: This column shows the number of gallons (lives) of water which will Flow
through 100 feet (30.48 metres) of the given tube and pipe with a pressure loss of 10
pounds per square inch (70 kilopascals). Flow is based on diameters in Column B
according to Professor Dawson's formulae for NEW galvanized iron pipe and NEW
capper tube. Due to the corrosion of iron and its tendency to accumulate sediments and
other foreign matter, Prof. Dawson suggests that 15% be deducted from the figures for
iron pipe in order to arrive at a reasonable performance expectancy for such pipe in
service. Because copper resists rust and is inherently more smooth, Professor Dawson
suggests a deduction of only 5% from the figures given for copper tube.
U.S. customary units in this document are the standard; the metric units are provided for
reference only The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
In the majority of low- pressure heating systems employing copper
tube and installed in small houses or private dwellings, provision for
expansion and contraction is relatively simple. Mains, risers, and
branches to radiators should be free or floating at one end of the
line. Holes should be large enough to permit free movement of the
tube, and care should be exercised so that pipe hangers and
supports permit unrestricted movement and do not anchor the tube.
Wrought copper tube hangers that are both practicable and neat in
appearance are available.
Unusually long runs of copper tubing should be provided with an
expansion bend or loop. By bending soft temper copper tube, a
simple form of expansion loop can be made. With the addition of
combination flared -tube to solder joint fittings, as illustrated in
Figure 1, these types of loops can be used when space or other
limitations exist. The correct proportions of such expansion loop to
meet various conditions are shown in the accompanying table.
FIGURE 1
A
P
a. U -Bend r
r
L
b. Coiled Loop
-------------
c. Offset and A
Return
8,45
010
z 040
a.33
Ia 631
= E am
a sa
U Z aai
¢o m 16 351
Z u am
25 E 15am
d i3lt!
X afa
W 11S4J
a 45
nm
■ ■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■
■ME■■■■■■■■■EW■
■■■■■■■■■■.M■■■
■■■■■■■■WeA■■■■
■ ■ ■ ■ ■ ■ ■��■■■
S NMENNEMENNOMON 'MMMMMIN
TBAPEAATtEtE, `F PCII
The above chart is calculated using 1 Oft (3.05m) of copper tubing as
the reference point. You may use it as follows: 1 00ft (30.5m) of
copper tube, with a 200 °F (93.3 °C) temperature change. Reference
point .2256 inches for 1 Oft, (5.73mm for 3.05m), multipy by 10 for
1 00f (30.5m), resulting in an answer of 2.256 inches (57.3mm) of
expansion or contraction.
NOTE: Calculations for expansion and contraction should be based
on the average coefficient of expansion of copper which is
0.0000094 per °F (0.00001692 per °C) between 77 °F and 212 °F
(25 °C and 100 °C). For example, the expansion for each 1 Oft (3.05m)
of any size of tube heated from room temperature of 707 (21.1 °C) to
170 °F (76.7 °C), that is, 100 °F (55.6 °C) rise, is:
Rise Coefficient
100 °F x 1Oft X 12 inches x 0.000094 _ 0.1128 in.
(55.6 °C) (3.05m) (1000mm) (0.00001692) - (2.87mm)
RADII OF
Nominal
Tube
Size
COILED EXPANSION LOOPS AND DEVELOPED LENGTHS OF EXPANSION OFFSETS
Expected Expansion
1/2 1 1112 2 21/2 3 31/2 4
R L R L R L R L R L R L R L R L
Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm) Inch (mm)
1/4
6 (152.4)
38 (965.2)
9 (228.6)
54 (1311.6)
11 (279.4)
66 (1676.4)
12 (304.8)
77 (1955.8)
14 (355.6)
86 (2184.4)
15 (381.0)
94 (2381.6)
16 (4064)
102 (2590.8)
17 (431.8)
109 (2768.6)
3/8
7 (177.8)
44 (1117.6)
10 (254.0)
63 (1600.2)
12 (304.8)
77 (1955.8)
14 (355.6)
89 (2260.6)
16 (406,4)
99 (2514.6)
17 (431.8)
109 (2168.6)
19 (482.6)
117 (2911.8)
20 (508.0)
126 (3200.4)
1/2
8 (203.2)
50 (1270.0)
11 (119.4)
70 (1118.0)
14 (355.6)
89 (2260.6)
16 (406.4)
99 (2514.6)
18 (4572)
111 (2819.4)
19 (482.6)
122 (3098.8)
21 (533.4)
131 (3327.4)
22 (558.8)
140 0556.0)
3/4
9 (228.6)
59 (1498.6)
13 (330.2)
83 (2108.2)
16 (406.4)
101 (2565.4)
19 (482.Q
117 (2911.8)
21 (533.4)
131 (3327.4)
23 (584.2)
143 (3632.4
25 (635.0
155 (3937.0)
26 (660.4)
166 (4216.4)
1
11 (219.4)
67 (1701.8)
15 (381.0)
94 (2387.6)
18 (457.4
115 (2921.0)
21 (533.4)
133 (3378.4
24 (609.6)
149 (3784.0
26 (660.4)
163 (4140.4
28 (711.)
176 (4410.4)
30 9620)
188 (4775.21
1 1/2
13 030.2)
80 (2032.0)
18 (457.2)
113 (2870.2)
22 (558.6)
138 (3505.2)
25 (635.)
160 (4064.0)
6)
179 (4546.6)
31 (181.4)
1% (4978.4)
34 (863.6)
212 (5384.8)
36 (914.4)
226 (5740.4)
2
15 (381.0)
91 (2311.4)
21 (533.4)
129 (3276.6)
25 (635.0)
158 (4013.71
29 (736.6)
163 (46482)
2)
205 (5207.0)
36 (914.4)
224 (5689.6)
39 (990.6)
242 (6146.8)
41 (1041.4)
259 (6578.6)
21/2
16 (406.4)
102 (2590.8)
23 (584.2)
144 (3657.0
28 RI 1.4
176 (4470.4)
32 (8128)
203 (5156.71
4)
227 (5165.8)
40 (1016.0)
249 (6324.6)
43 (1092.4
269 (6832.6)
46 (11664)
288 U315A
3
18 (457.2)
111 (1819.4)
25 (635.0)
157 (3987.8)
30 962.0
191 (4851.4)
35 (889.0
222 (5638.8)
P36O14.4)
0)
248 (6299.2)
43 (1092.2)
272 (69068)
47 (1193.8)
293 (/4422)
50 (1270.0)
314 (7975.6)
31/2
19 (4826)
120 (30460)
27 (685.8)
169 (42926)
33 (838.2)
206 (5232.4)
38 (965.1
239 (6070.6)
2)
267 (6781.8)
47 (1193.8)
293 9442.2)
50 (1270.0
316 (8026.4)
54 (1371.0
338 (8585.2)
4
20 (508.0
128 0251.4
29 (136.6)
180 (4572.0
35 (689.0
220 (5588.0
41 (1041.4)
255 (6477.0
.0
285 Q239.0)
50 (1210.0)
312 Q924.8)
54 (1311.6)
3 (8559.8)
51 (1441.8)
361 (9169.4)
5
23 (584.2)
142 (3606.8)
32 (812.8)
201 (5105.4)
39 �J90.6)
245 (6223.0)
45 (1143.0
284 (7213.6)
.4)
318 (&177.2)
55 (1397.0)
348 (8839.)
60 (1524.0
376 (9550.4)
64 (1625.6)
402(10210.8)
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.95.3455
25 75 135 175 225 375 325
{ -am (2391 01 (M40 047n 0550 "4251
Copper Water Tube,ontinued
I:
The smooth interior of copper tube, and the design of both solder joint and flared- tube -type fittings, which have no shoulders projecting into
the flow of water, decrease friction loss. With the use of copper tube, no allowance is necessary for the accumulation of rust deposits in supply
and service lines. Consequently, copper tube lines are usually figured one size smaller than iron pipe for the same service. This rule does not
apply to lines from a well to a pump where the nominal diameters specified by the pump manufacturer must be adhered to strictly.
Water passing through any pipe line encounters resistance by friction. The resistance is increased by bends and turns in the line, which should
be taken into account in complex piping systems. For example, a one -inch 90° elbow will cause friction loss equivalent to that of one foot
(0.305m) of straight one -inch tube. (See below for allowance to be made for fittings and valves in equivalent lengths of tube.) Friction loss in
terms of head loss must be taken into consideration in calculating tube sizes to be used for various types of installations.
For most average- size -house installations with water pressures 40 PSI (275.8kPa) and higher, 3/4„ copper tube will be ample for main supply
lines, and '12" copper tube can be used for risers and branches to all fixtures. The smaller 3 /8" tube is adequate to supply branches, but with
pressures at 40 PSI (275.8kPa) and higher, water hammer becomes a concern when the flow is suddenly stopped.
APPROXIMATE
Nominal
Tube Size
(In Inches)
FRICTION i
Wrought- Copper Fittings
90° 45° Tee Tee 90° 180°
Elbow Elbow Run Side Outlet Bend Bend
Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) Feet (m)
Cast Copper Alloy Fittings and Valves
45° Tee Tee Comp. Globe Gate
Elbow Run Side Outlet Stop Valve Valve
Feet (m) Feet (m) Feet (m) Feet (m) Feet (m) Feet (m)
3/8
0.5 (0.15)
0.5 (0.15)
0.5 (0.15)
1 (0.31)
0.5 (0.15)
0.5 (0.15)
L2(O.61)
0.5 (0.15)
0.5 (0.15)
2 (0.61)
9 (2.75)
- -
- -
112
0.5 (0.15)
0.5 (0.15)
0.5 (0.15)
1 (0.31)
0.5 (0.15)
1 (0.31)
0.5 (0.15)
0.5 (0.15)
2 (0.61)
13 (3.97)
- -
- -
5/8
0.5 (0.15)
0.5 (0.15)
0.5 (0.15)
2 (0.61)
1 (0.31)
1 (0.31)
1 (0.31)
0,5 (0.15)
3 (0.92)
17 (5.19)
- -
- -
3/4
1 (0.31)
0.5 (0.15)
0.5 (0.15)
2 (0.61)
1 (0.31)
2 (0.61)
2 (0.61)
1 (0.31)
0.5 (0.15)
3 (0.92)
21 (6.41)
- -
- -
1
1 (0.31)
1 (0.31)
0.5 (0.15)
3 (0.92)
2 (0.61)
2 (0.61)
4 (1.22)
2 (0.61)
0.5 (0.15)
5 (1.53)
30 (9.15)
- -
1 (0.31)
11/4
2 (0.61)
1 (0.31)
0.5 (0.15)
4 (122)
2 (0.61)
3 (0.92)
5 (1.53)
2 (0.61)
1 (0.31)
7 (2.14)
- -
53 (16.17)
1 (0.31)
1112
2 (0.61)
2 (0.61)
1 (0.31)
5 (1.53)
2 (0.61)
4 (1.22)
8 (2.44)
3 (0.92)
1 (0.31)
9 (2.75)
- -
66 (20.13)
2 (0.61)
2
2 (0.61)
2 (0.61)
1 (0.31)
7 (2.14)
3 (0.92)
8 (2.44)
11 (3.36)
5 (1.53)
2 (0.61)
12 (3.66)
- -
90 (27.45)
2 (0.61)
2112
2 (0.61)
3 (0.92)
2 (0.61)
9 (2.75)
4 (1.22)
16 (4.88)
14 (4.27)
8 (2.44)
2 (0.61)
16 (4.88)
- -
- -
2 (0.61)
3
3 (0.92)
4 (1.22)
- -
- -
5 (1.53)
20 (6.10)
18 (5.49)
11 (3.36)
2 (0.61)
20 (6.10)
- -
- -
2 (0.61)
31/2
4 (1.22)
- -
- -
- -
7 (2.14)
24 (1.32)
24 (7.32)
14 (4.27)
2 (0.61)
31 (9.46)
- -
- -
2 (0.61)
4
- -
- -
- -
- -
8 (2.44)
28 (8.54)
28 (8.54)
17 (5.19)
2 (0.61)
37 (11.29)
- -
- -
2 (0.61)
5
- -
- -
- -
- -
10 (3.05)
37 (11.29)
41 (12.51)
22 (6.71)
2 (0.61)
48 (14.64)
- -
- -
- -
6
- -
- -
- -
- -
13 (3.97)
47 (14.34)
52 (15.86)
28 (8.54)
2 (0.61)
61 (18.61)
- -
- -
- -
Notes: This table is based on tests conducted at Harvard University (1948).
If the type of fitting is not known - i.e., whether wrought copper or cast alloy -use cast copper alloy values for design.
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800,234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455
1
112
550 (37.92)
Service Temperature °F ( °C)
370 (25.51)
410 (28.27)
1 340 (23.44)
270 (18.62)
100 °F (37.8 °C)
200 °F (93.3 °C)
300 °F (148.9
°C)
400 °F (204.4 °C)
Nominal
S = 6000psi (414 bars)
S = 4800psi (331 bars)
S =4700 psi (324 bars)
S =3000 psi (207 bars)
Tube Size
345 (23.79)
305 (21.03)
230 (15.86)
190
112
450 (31.03)
(In Inches)
Type K Type L I Type M
Type K Type L Type M
Type K
I Type L
Type K
I Type L
1/4
1210 (83.43)
1025 90.67)
- -
850 (58.61)
700 (48.27)
- -
830 (57.23)
690 (47.58)
530 (36.54)
450 (31.03;
3/8
1275 (87.91)
890 (61.31)
625 (43.09)
930 (64.12)
630 (43.44)
460 (31.72)
910 (62.74)
610 (42.06)
590 (40.68)
400 (27.58;
1/2
1005(69.29)
810 (55.85)
560 (38.61)
730 (50.33)
580 (39.99)
415 (28.61)
1 720 (49.64)
570 (39.30)
460 (31.72)
1370 (25.51;
5/8
1830 (57.23)
705 (48.61)
- -
600 (41.31)
1 500 (34.48)
- -
1 580 (39.99)
500 (34.48)
380 (26.20)
1330 (22.75;
1
112
550 (37.92)
455 (31.37)
370 (25.51)
410 (28.27)
1 340 (23.44)
270 (18.62)
400 (27.58)
330 (22.75)
260 (17.93)
1220
2
485 (33.44)
405 (27.92)
335 (23.10)
350 (24.13)
310 (21.37)
240 (16.55)
345 (23.79)
305 (21.03)
230 (15.86)
190
112
450 (31.03)
375 (25.86)
305 (21.03)
330 (22.75)
275 (18.96)
220 (15.17)
320 (22.06)
270 (18.62)
210 (14.48)
180
3
430 (29.65)
355 (24.48)
280 (19.31)
320 (22.06)
260 (17.93)
205 (14.13)
315 (21.72)
255 (17.58)
210 (14.48)
170
1/2
410 (28.27)
340 (23.44)
280 (19.31)
300 (20.69)
250 (17.24)
200 (13.79)
300 (20.69)
245 (16.89)
190 (13.10)
160
4
400 (27.58)
325 (22.41)
280 (19.31)
295 (20.34)
240 (16.55)
200 (13.79)
290 (20.00)
235 (16.20)
190 (13.10)
150
5
385 (26.55)
300 (20.69)
260 (17.93)
290 (20.00)
220 (15.17)
190 (13.10)
280 (19.31)
215 (14.82)
180 (12.41)
140
6
385 (26.55)
280 (19.31)
240 (16.55)
280 (19.31)
205 (14.13)
180 (12.41)
280 (19.31)
200 (13.79)
190 (13.10)
130
8
410 (28.27)
300 (20.69)
255 (17.58)
300 (20.69)
220 (15.17)
190 (13.10)
300 (20.69)
215 (14.82)
200 (13.79)
140
10
410 (28.27)
300 (20.69)
255 (17.58)
310 (21.37)
225 (15.51)
190 (13.10)
305 (21.03)
220 (15.17)
200 (13.79)
150
12
410 (28.27)
280 (19.31)
225 (15.51)
310 (21.37)
210 (14.48)
190 (13.10)
305 (21.03)
205 (14.13)
200 (13.79)
140
'Rated internal pressures for Copper Water Tube based on the strength of the tube alone and
applicable to systems using suitable mechanicaljoints.
The values are based on the formula in the American Standard Code,
Power Piping ANSI /ASME B31.1 1992.
Formulas
PD
tm= 2S +0.8P +C
or
P_ 2 S tm When C is 0
D -0.8tm
tm Minimum tube wall thickness
P Maximum rated internal
working pressure
D Outside diameter of tube
S Allowable stress in material
due to internal pressure at
operating temperature
c Allowance for threading, mechanical
strength and /or corrosion
U.S. customary units in this document are the standard; the metric units are provided for
reference only The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Hazen Wi I I iams Formula
Maximum O.D. = 0.3760 inches (9.550 mm) Nominal O.D. = 0,3750 inches (9.525 mm)
Minimum O.D. = 0.3740 inches (9.499 mm) Nominal I.D. = 0.3050 inches (7.747 mm)
Nominal Wall Thickness = 0.0350 inches (0.089 mm) Flow Area = 0.0731 sq. inches (47.14 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocit
(m /sec
0.50
3.77
8.81
2.20
32
0.85
8.81
0.67
1.00
13.62
31.77
4.39
63
3.08
31.77
1.34
1.50
28.86
67.27
6.59
95
6.53
67.27
2.01
2.00
49.17
114.54
8.78
126
11.12
114.54
2.68
2.50
74.33
173.08
10.98
158
16.81
173.08
3.35
3.00
1 104.18
242.51
1 13.17
1 189
1 23.57
1 242.51
4.02
3.50
138.60
322.54
15.37
221
31.35
32154
4.68
4.00
177.49
412.92
17.57
252
40.15
412.92
5.35
4.50
220.75
513.46
19.76
284
1
49.94
513.46
6.02
5.00
268.32
623.96
21.96
315
60.70
623.96
6.69
Hazen Williams Formula
Maximum O.D. = 0.3760 inches (9.550 mm) Nominal O.D. = 0.3750 inches (9.525 mm)
Minimum O.D. = 0.3740 inches (9.499 mm) Nominal I.D. = 0.3150 inches (8.001 mm)
Nominal Wall Thickness = 0.0300 inches (0.076 mm) Flow Area = 0.0779 sq. inches (50.28 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
0.50
3.22
7.53
2.06
32
0.73
7.53
0.63
1.00
11.64
27.16
4.12
63
2.63
27.16
1.25
1.50
24.67
57.50
6.18
95
5.58
57.50
1.88
2.00
42.02
97.90
8.23
126
9.51
97.90
2.51
2.50
6153
147.94
10.29
158
14.37
147.94
3.14
3.00
89.05
207.28
12.35
189
20.14
207.28
3.76
3.50
118.47
275.69
14.41
221
26.80
275.69
4.39
4.00
151.71
352.94
16.47
252
34.32
352.94
5.02
4.50
188.68
438.87
18.53
284
42.68
438.87
5.65
5.00
229.34
533.32
20.58
315
51.88
533.32
6.27
Hazen Williams Formula
Maximum O.D. = 0.5010 inches (12.725 mm) Nominal O.D. = 0.5000 inches (12.100 mm)
Minimum O.D. = 0.4990 inches (12.674 mm) Nominal I.D. = 0.4020 inches (10.210 mm)
Nominal Wall Thickness = 0.0490 inches (1.244 mm) Flow Area = 0.1269 sq. inches (81.89 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 Ft)
Head Loss
(ft/100 ft)
Velocity
(ft /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
1.00
3.55
8.29
2.53
63
0.80
8.29
0.77
1.50
7.53
17.55
3.79
95
130
17.55
1.16
2.00
12.83
29.89
5.06
126
2.90
29.89
1.54
2.50
19.39
45.16
6.32
158
4.39
45.16
1.93
3.00
27.18
63.28
7.58
189
6.15
63.28
2.31
3.50
36.16
84.16
8.85
221
8.18
84.16
2.70
4.00
46.31
107.74
10.11
252
10.48
107.74
3.08
4.50
57.60
133.97
11.37
284
13.03
133.97
3.47
5.00
70.01
162.80
12.64
315
15.84
162.80
3.85
5.50
83.52
194.19
13.90
347
18.89
194.19
4.24
6.00
98.13
228.11
1517
379
22.20
228.11
4.62
6.50
113.81
264.51
16.43
410
25.74
264.51
5.01
7.00
130.55
303.38
17.69
442
29.53
303.38
5.39
7.50
148.34
344.68
18.96
473
33.56
344.68
5.78
8.00
167.18
388.40
20.22
505
37.82
388.40
6.16
8.50
187.04
434.49
21.49
536
42.31
434.49
6.55
9.00
207.93
482.96
22.75
568
47.03
482.96
6.93
9.50
229.83
1 533.76
24.01
599
51.99
1 533.76
7.32
10.00
252.73
1 586.89
1 25.28
1 631
57.17
1 586.89
7.70
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST- • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
TYPE COPPER " 1 1 FRICTION LOSS 11 FEET
Maximum O.D. = 0.5010 inches (12.725 mm) Nominal O.D. = 0.5000 inches (12.700 mm)
Minimum O.D. = 0.4990 inches (12.675 mm) Nominal I.D. = 0.4500 inches (10.211 mm)
Nominal Wall Thickness = 0.0350 inches (0.889 mm) Flow Area = 0.1590 sq. inches (102.61 sq, mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
1.00
2.56
5.97
2.21
63
0.58
5.97
0.67
1.50
5.43
12.65
3.31
95
1.23
12.65
1.01
2.00
9.24
21.54
4.42
126
2.09
21.54
1.35
2.50
13.98
32.54
5.52
158
3.16
32.54
1.68
3.00
19.59
45.60
6.63
189
4.43
45.60
2.02
3.50
26.06
60.65
7.73
221
5.90
60.65
2.36
4.00
33.37
77.64
8.84
252
7.55
77.64
2.69
4.50
41.51
96.54
9.94
284
9.39
96.54
3.03
5.00
50.45
117.32
11.05
315
11.41
117.32
3.37
5.50
60.19
139.94
12.15
347
13.62
139.94
3.70
6.00
70.72
164.38
13.26
379
16.00
164.38
4.04
6.50
82.01
190.62
14.36
410
18.55
190.62
4.38
7.00
94.08
218.63
15.46
442
21.28
218.63
4.71
7.50
106.90
248.40
16.57
473
24.18
248.40
5.05
8.00
120.48
279.90
17.67
505
2725
279.90
5.39
8.50
134.79
313.12
18.78
536
1 30A9
313.12
1 5.72
9.00
149.84
1 348.04
19.88
568
1 3190
348.04
6.06
9.50
1 165.62
1 384.65
20.99
599
1 37.47
384.65
6.40
10.00
182.13
422.94
2209 ,
631
1 41.20
422.94
6.73
COPPER " ' 1 AND FRICTION LOSS II FEET
Maximum O.D. = 0.5010 inches (12.725 mm) Nominal O.D. = 0.5000 inches (12.700 mm)
Minimum O.D. = 0.4990 inches (12.675 mm) Nominal I.D. = 0.4020 inches (10.211 mm)
Nominal Wall Thickness = 0.0250 inches (0.635 mm) Flow Area = 0.1269 sq, inches (81.89 sq. mm)
Ha7Bn Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec
1.00
2.05
4.79
2.02
63
0.46
4.79
0.61
1.50
4.35
10.14
3.03
95
0.98
10.14
0.92
2.00
7.41
17.26
4.03
126
1.68
17.26
1.23
2.50
11.20
26.09
5.04
158
2.53
26.09
1.54
3.00
15.70
36.55
6.05
189
3.55
36.55
1.84
3.50
20.89
48.61
7.06
221
4.73
48.61
2.15
4.00
26.75
62.23
8.07
252
6.05
62.23
2.46
4.50
3127
77.39
9.08
284
7.53
77.39
2.77
5.00
40.44
94.04
10.09
315
9.15
94.04
3.07
5.50
48.25
112.17
11.09
347
10.91
112.17
3.38
600
56.68
131.76
12.10
379
12.82
131.76
3.69
6.50
65.74
152.79
13.11
410
14.87
152.79
4.00
7.00
75.41
175.25
14.12
442
17.06
175.25
4.30
7.50
85.69
199.10
15.13
473
19.38
199.10
4.61
8.00
96.57
224.35
16.14
505
21.84
224.35
4.92
8.50
108.04
250.98
17.15
536
24.44
250.98
5.23
9.00
120.11
1 278.97
18.16
568
27.17
278.97
5.53
9.50
1 132.76
1 30832
19.16
599
30.03
308.32
5.84
10.00
1 145.99
1 339.01
20.17
631
1 33.02
1 339.01
6.15
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS ' 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.514.295.3221 • FAX: +1.574.295.3455
COPPER WATER AND FRICTION LOSS PER 100 FEET
Maximum O.D. = 0.626 inches (15.900 mm) Nominal O.D. = 0.6250 inches (15.875 mm)
Minimum O.D. = 0.624 inches (15.850 mm) Nominal I.D. = 0.527 inches (13.3858 mm)
Nominal Wall Thickness = 0.049 inches (1.245 mm) Flow Area = 0.2181 sq. inches (140.73 sq, mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(f /100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
1.00
0.95
2.22
1.47
63
0.22
2.22
0.45
1.50
2.02
4.70
2.21
95
0.46
4.70
0.67
2.00
3.44
8.00
2.94
126
0.78
8.00
0.90
2.50
5.19
12.10
3.68
158
1.18
12.10
1.12
3.00
7.28
16.95
4.41
189
1.65
16.95
1.34
3.50
9.69
22.54
5.15
221
2.19
22.54
1.57
4.00
12.40
28.86
5.88
252
2.81
28.86
1.79
4.50
15.43
35.88
6.62
284
3.49
35.88
2.02
5.00
18.75
43.61
7.35
315
4.24
43.61
2.24
5.50
22.37
52.01
8.09
347
5.06
52.01
2.47
6.00
2628
61.10
8.83
379
5.95
61.10
2.69
6.50
30.48
70.85
9.56
410
6.90
70.85
2.91
7.00
34.97
81.26
10.30
442
7.91
81.26
3.14
7.50
39.73
92.32
11.03
473
8.99
92.32
3.36
8.00
44.78
104.03
11.77
505
10.13
104.03
3.59
8.50
50.10
116.38
12.50
536
11.33
116.38
3.81
9.00
55.69
129.36
13.24
568
12.60
129.36
4.03
9.50
61.56
142.97
13.97
599
13.93
1 142.97
4.26
10.00
67.69
157.20
14.71
631
15.31
157.20
4.48
10.50
74.10
172.05
15.44
662
16.76
172.05
4.71
11.00
80.76
187.51
16.18
694
18.27
187.51
4.
11.50
87.69
203.58
16.91
725
19.84
203.58
5.16
12.00
94.88
220.26
17.65
757
21.46
220.26
5.38
12.50
102.34
1 237.54
1 18.39
789
23.15
237.54
5.60
13.00
110.05
255.41
19.12
820
24.89
255.41
5.83
13.50
118.01
273.89 1
19.86
852
26.70
273.89
6.05
14.00
126.23
292.95 1
20.59 1
883
28.56 1
292.95
6.28
Hazen Williams Formula
Maximum O.D. = 0.626 inches (15.900 mm) Nominal O.D. = 0.6250 inches (15.875 mm)
Minimum O.D. = 0.624 inches (15.850 mm) Nominal I.D. = 0.5450 inches (13.843 mm)
Nominal Wall Thickness = 0.049 inches (1.245 mm) Flow Area = 0.2333 sq. inches (150.50 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(fV100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
1.00
0.81
1.89
1.38
63
0.18
1.89
0.42
1.50
1.71
3.99
2.06
95
039
3.99
0.63
2.00
2.92
6.80
2.75
126
0.66
6.80
0.84
2.50
4.41
10.27
3.44
158
1.00
10.27
1.05
3.00
6.18
14.39
4.13
189
1.40
14.39
1.26
3.50
8.23
19.14
4.81
221
1.86
19.14
1.47
4.00
10.53
24.51
5.50
252
2.38
24.51
1.68
4.50
1310
30.47
6.19
284
2.96
30.47
1.89
5.00
15.92
37.03
6.88
315
3.60
37.03
2.10
5.50
19.00
44.17
7.56
347
4.30
44.17
2.31
6.00
22.32
51.89
8.25
379
5.05
51.89
2.52
6.50
25.89
60.17
8.94
410
5.86
60.17
2.72
7.00
29.70
69.01
9.63
442
6.72
69.01
2.93
7.50
33.74
78.41
10.31
473
7.63
78.41
3.14
8.00
38.03
88.35
11.00
505
8.60
88.35
3.35
8.50
42.55
98.83
11.69
536
9.62
98.83
3.56
9.00
47.30
109.86
12.38
568
10.70
109.86
3.77
9.50
52.28
121.41
13.07
599
11.83
121.41
3.98
10.00
57.49
133.50
13.75
631
13.00
133.50
4.19
10.50
62.92
146.11
14.44
662
14.23
146.11
4.40
11.00
68.59
159.24
15.13
694
15.51
159.24
4.61
11.50
74.47
172.89
15.82
725
16.85
172.89
4.82
12.00
80.58
187.05
1 16.50
1 757
1 18.23
1 187.05
5.03
12.50
86.91
201.73
17.19
789
19.66
201.73
5.24
13.00
93.46
216.91
17.88
820
21.14
216.91
5.45
13.50
10022
232.60
18.57
852
22.67
232.60
5.66
14.00
107.20
248.78
19.25
883
24.25
248.78
5.87
U.S. customary units in this document are the standard; the metric units are provided for
reference only The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.514.295.3221 • FAX: +1.574.295.3455
COPPER i LOSS ('
Maximum O.D. = 0.626 inches (15.900 mm) Nominal O.D. = 0.6250 inches (15.875 mm)
Minimum O.D. = 0.624 inches (15.850 mm) Nominal I.D. = 0.5690 inches (14.4526 mm)
Nominal Wall Thickness = 0.028 inches (0.711 mm) flow Area = 0.2543 sq. inches (164.05 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
1.00
0.66
1.53
1.26
63
0.15
1.53
0.38
1.50
1.39
3.24
1.89
95
0.31
3.24
0.58
2.00
2.37
5.51
2.52
126
0.54
5.51
0.77
2.50
3.58
8.33
3.15
158
0.81
8.33
0.96
3.00
5.01
11.67
3.79
189
1.13
11.67
1.15
3.50
6.67
15.52
4.42
221
1.51
15.52
1.35
4.00
8.54
19.87
5.05
252
1.93
19.87
1.54
4.50
10.62
24.71
5.68
284
2.40
24.71
1.73
5.00
12.91
30.03
6.31
315
2.92
30.03
1.92
5.50
15.41
35.82
6.94
347
3.48
35.82
2.12
6.00
18.10
42.07
7.57
379
4.09
42.07
2.31
6.50
20.99
48.79
8.20
410
4.75
48.79
2.50
7.00
24.08
55.96
8.83
442
5.45
55.96
2.69
7.50
27.36
63.57
9.46
473
6.19
63.57
2 .88
8.00
30.83
71.64
10.09
505
6.98
71.64
3.08
8.50
34.50
80.14
10.72
536
7.80
80.14
3.27
9.00
38.35
89.08
11.36
568
8.68
89.08
3.46
9.50
42.39
98.45
11.99
599
9.59
98.45
3.65
10.00
46.61
108.25
12.62
631
10.54
108.25
3.85
10.50
51.02
118.47
13.25
662
11.54
118.47
4.04
11.00
55.61
129.12
13.88
694
12.58
129.12
4.23
11.50
60.39
140.19
14.51
725
13.66
140.19
4.42
12.00
65.34
1 151.67
15.14
757
14.78 1
151.67
1 4.61
12.50
70.47
163.57
15.77
789
15.94
163.57
4.81
13.00
75.78
175.88
16.40
820
17.14
175.88
5.00
13.50
81.26
188.60
17.03
852
18.38
188.60
5.19
14.00
86.93
201.72
17.66
883
19.66
201.72
5.38
Hazen Williams Formula
Maximum O.D. = 0.751 inches (19.075 mm) Nominal O.D. = 0.7500 inches (19.050 mm)
Minimum O.D. = 0.749 inches (19.025 mm) Nominal I.D. = 0.6520 inches (16.5608 mm)
Nominal Wall Thickness = 0.049 inches (1.245 mm) Flow Area = 0.3339 sq. inches (215.40 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
1.00
0.34
0.79
0.96
63
0.08
0.79
0.29
2.00
1.22
2.84
1.92
126
0.28
2.84
0.59
3.00
2.58
6.02
2.88
189
0.58
6.02
0.88
4.00
4.40
10.24
3.84
252
1.00
10.24
1.17
5.00
6.66
15.48
4.80
315
1.51
15.48
1.46
6.00
9.33
21.69
5.77
379
211
21.69
1.76
7.00
12.41
28.85
6.73
442
2.81
28.85
2.05
8.00
15.90
36.93
7.69
505
3.60
36.93
2.34
9.00
19.77
45.92
8.65
568
4.47
45.92
2.64
10.00
24.03
55.81
9.61
631
5.44
55.81
2.93
11.00
28.67
66.57
10.57
694
6.49
66.57
3.22
12.00
33.69
78.20
11.53
757
7.62
78.20
3.51
13.00
39.07
90.68
12.49
820
8.84
90.68
3.81
14.00
44.82
104.00
13.45
883
10.14
104.00
4.10
15.00
50.92
118.16
14.41
946
11.52
118.16
4.39
16.00
57.39
133.14
15.37
1009
12.98
133.14
4.69
17.00
64.21
148.95
16.34
1072
14.52
148.95
4.98
18.00
71.38
165.56
17.30
1136
16.15
165.56
5.27
19.00
78.89
182.98
18.26
1199
17.85
182.98
5.56
20.00
86.76
201.19
19.22
1262
19.63
201.19
5.86
21.00
94.96
220.19
20.18
1325
21.48
220.19
6.15
22.00
103.51
239.98
21.14
1388
23.41
239.98
6.44
U.S. customary units in this document are the standard; the metric units are provided for
reference only The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
' COPPER " 1 / AND FRICTION LOSS II FEET
Maximum O.D = 0.751 inches (19.075 mm) Nominal O.D. = 0.7500 inches (19.050 mm)
Minimum O.D. = 0.749 inches (19.025 mm) Nominal I.D. = 0.6660 inches (16.9164 mm)
Nominal Wall Thickness = 0.042 inches (1.067 mm) Flow Area = 0.3484 sq. inches (224.75 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(fU100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
1.00
0.30
0.71
0.92
63
0.07
0.71
0.28
2.00
1.10
2.56
1.84
126
0.25
2.56
0.56
3.00
2.33
5.43
2.76
189
0.53
5.43
0.84
4.00
3.97
9.24
3.68
252
0.90
9.24
1.12
5.00
6.00
13.96
4.60
315
1.36
13.96
1.40
6.00
8.41
19.56
5.53
379
1.90
19.56
1.68
7.00
11.20
26.02
6.45
442
2.53
26.02
1.96
8.00
14.34
33.31
7.37
505
3.24
33.31
225
9.00
17.83
41.41
8.29
568
4.03
41.41
2.53
10.00
21.67
50.33
9.21
631
4.90
50.33
2.81
11.00
25.86
60.03
10.13
694
5.85
60.03
3.09
12.00
30.38
70.52
11.05
757
6.87
70.52
3.37
13.00
35.23
81.77
11.97
820
7.97
81.77
3.65
14.00
40.41
93.79
12.89
883
9.14
93.79
3.93
15.00
45.92
106.56
13.81
946
10.39
106.56
4.21
16.00
51.75
120.07
14.74
1009
11.71
120.07
4.49
17.00
57.90
134.32
15.66
1072
13.10
134.32
4.77
18.00
64.37
149.30
16.58
1136
14.56
14930 1
5.05
19.00
71.15
165.01
17.50
1199
16.09
165.01
5.33
20.00
78.24
181.43
18.42
1262
17.70
181.43
5.61
21.00
85.64
198.57
1934
1325
19.37
198.57
5.89
22.00
93.34
216.42
20.26
1388
21.11
216.42
6.18
COPPER " 1 1 AND FRICTION LOSS II FEET
Maximum O.D. = 0.876 inches (22.250 mm) Nominal O.D. = 0.8750 inches (22.225 mm)
Minimum O.D. = 0.874 inches (22.200 mm) Nominal I.D. = 0.7450 inches (18.923 mm)
Nominal Wall Thickness = 0.065 inches (1.651 mm) Flow Area = 0.4359 sq. inches (281.24 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
2.00
0.64
1.49
1.47
126
0.14
1.49
0.45
4.00
2.30
5.35
2.94
252
0.52
5.35
0.90
6.00
4.88
11.34
4.42
379
1.10
11.34
1.35
8.00
8.31
19.30
5.89
505
1.88
19.30
1.79
10.00
12.56
29.17
7.36
631
2.84
29.17
2.24
12.00
17.61
40.87
8.83
757
3.98
40.87
2.69
14.00
23.42
54.36
10.30
883
5.30
54.36
3.14
16.00
30.00
69.59
11.78
1009
6.79
69.59
3.59
18.00
37.31
86.54
13.25
1136
8.44
86.54
4.04
20.00
45.35
105.16
14.72
1262
10.26
105.16
4.49
22.00
54.10
125.44
16.19
1388
12.24
125.44
4.94
24.00
63.56
147.34
17.66
1514
14.38
147.34
5.38
26.00
73.72
170.86
1914 ,
1640
16.68
170.86
5.83
28.00
84.56
195.97
20.61
1766
1 19.13
1 195.97
6.28
30.00
96.09
222.65
22.08
1893
1 21.74
1 222.65
6.73
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA ' PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574295.3455
O" ER TUBE - WATER FLOW r ► FRICTION LOSS PER 100 FEET
Maximum O.D. = 0.876 inches (22.250 mm) Nominal O.D. = 0.8750 inches (22.225 mm)
Minimum O.D. = 0.874 inches (22.200 mm) Nominal I.D. = 0.7850 inches (19.939 mm)
Nominal Wall Thickness = 0.045 inches (1.143 mm) Flow Area = 0.4840 sq, inches (312.25 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
2.00
0.4944
1.1517
1.3258
12617
0.1118
1.1517
0.4041
4.00
1.7846
4.1519
16516
25235
0.4037
4.1519
0.8082
6.00
3.7815
8.7905
3.9774
378.52
0.8554
8.7905
1.2123
8.00
6.4425
14.9675
5.3032
504.69
1.4573
14.9675
1.6164
10.00
93393
22.6169
6.6290
630.87
2.2031
22.6169
2.0205
12.00
13.6513
31.6896
7.9548
757.04
10880
31.6896
2.4246
14.00
18.1618
42.1472
9.2806
883.21
4.1083
42.1472
2.8287
16.00
23.2573
53.9578
10.6064
1009.39
5.2610
53.9578
3.2328
18.00
28.9264
67.0944
11.9322
1135.56
6.5434
67.0944
3 .6369
20.00
35.1590
81.5338
13.2580
1261.73
7.9532
81.5338
4.0
22.00
41.9465
97.2555
14.5838
1 1387.91
9.4886
1 97.2555
1 4.4452
24.00
49.2811
114.2412
15.9096
1514.08
11.1477
114.2412
4.8493
26.00
57.1557
132.4747
17.2354
1640.25
12.9290
132.4747
5.2534
28.00
65.5641
151.9408
18.5613
1766.43
14.8311
151.9408
5.6575
30.00
74.5002
172.6261
19.8871
1892.60
16.8525
172.6261
6.0616
Hazen Williams Formula
Maximum O.D. = 0.876 inches (22.250 mm) Nominal O.D. = 0.8750 inches (22.225 mm)
Minimum O.D. = 0.874 inches (22.200 mm) Nominal I.D. = 0.8110 inches (20.5994 mm)
Nominal Wall Thickness = 0.032 inches (0.813 mm) Flow Area = 0.5156 sq. inches (333,27 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.
2.00
0.42
0.98
1.24
126
0.10
0.98
0.38
4.00
1.52
3.54
2.48
252
0.34
3.54
0.76
6.00
3.23
7.50
3.73
379
0.73
7.50
1.14
8.00
5.50
12.11
4.97
505
1.24
1237
1.51
10.00
8.31
19.30
6.21
631
1.88
1930
1.89
12.00
11.65
27.04
7.45
757
2.64
27.04
2.27
14.00
15.50
35.97
8.70
883
3.51
35.97
2.65
16.00
19.85
46.05
9.94
1009
4.49
46.05
3.03
18.00
24.69
57.26
11.18
1136
5.58
57.26
3.41
20.00
30.00
69.58
12.42
1262
6.79
69.58
3.79
22.00
35.80
83.00
13.66
1388
8.10
83.00
1 4.16
24.00
42.06
97.49
14.91
1514
9.51
1 97.49
4.54
26.00
48.78
113.05
16.15
1640
11.03
113.05
4.92
28.00
55.95
129.66
17.39
1766
12.66
129.66
5.30
30.00
63.58
147.32
18.63
1 1893
14.38
147.32
5.68
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART. IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
COPPER 1 1 FRICTION LOSS PER II FEET
Maximum O.D. = 1.1265 inches (28.613 mm) Nominal O.D = 1.1250 inches (28.575 mm)
Minimum O.D. = 1.1235 inches (28.537 mm) Nominal I.D. = 0.9850 inches (25.273 mm)
Nominal Wall Thickness = 0.0650 inches (1.651 mm) Flow Area = 0.7776 sq. inches (501.65 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
2.50
0.24
0.55
1.03
158
0.05
0.55
0.31
5.00
0.85
1.98
2.06
315
0.19
1.98
0.63
7.50
1.80
4.19
3.09
473
0.41
4.19
0.94
10.00
3.07
7.14
4.13
631
0.70
7.14
1.26
12.50
4.65
1038
5.16
789
1.05
10.78
1.57
15.00
6.51
1511
6.19
946
1.47
15.11
1.89
17.50
8.66
2010
7.22
1104
1.96
20.10
2.20
20.00
11.09
25.73
8.25
1262
2.51
25.73
2.52
22.50
13.80
31.99
9.28
1419
3.12
31.99
2.83
25.00
16.77
38.88
10.32
1577
3.79
38.88
3.14
27.50
20.01
46.37
11.35
1735
4.53
46.37
3.46
30.00
23.51
54.47
12.38
1893
5.32
54.47
3.77
32.50
27.27
63.17
13.41
2050
6.17
63.17
4.09
35.00
31.28
72.45
14.44
2208
7.08
72.45
4.40
37.50
35.54
82.31
15.47
2366
8.04
82.31
4.72
40.00
40.05
92.75
16.50
2523
9.06
92.75
5.03
42.50
44.81
103.76
17.54
2681
10.14
103.76
5.34
45.00
49.81
115.33
18.57
2839
11.27
115.33
5.66
47.50
55.06
127.47
19.60
2997
12.46
127.47
5.97
50.00
60.55
140.15
20.63
3154
13.70
140.15
6.29
52.50
66.27
153.39
21.66
3312
14.99
153.39
6.60
55.00
72.24
167.18
22.69
3470
16.34
167.18
6.92
' COPPER " 1 1 FRICTION LOSS II FEET
Maximum O.D. = 1.1265 inches (28.613 mm) Nominal O.D. = 1.1250 inches (28.575 mm)
Minimum O.D. = 1.1235 inches (28.537 mm) Nominal l.0, = 1.0250 inches (26.035 mm)
Nominal Wall Thickness = 0.0500 inches (1.270 mm) Flow Area = 0.8252 sq inches (532.36 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/ 100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
2.50
0.20
0,48
0.97
158
0.05
0.48
0.30
5.00
0.74
1.71
1.94
315
0.17
1.71
0.59
7.50
1.56
3.63
2.92
473
0.35
3.63
0.89
10.00
2.66
6.18
3.89
631
0.60
6.18
1.19
12.50
4.02
9.33
4.86
789
0.91
9.33
1.48
15.00
5.64
13.08
5.83
946
1.27
13.08
1.78
17.50
7.50
17.39
6.80
1104
1.70
17.39
2.07
20.00
9.60
22.27
7.78
1262
2.17
22.27
2.37
22.50
11.94
27.69
8.75
1419
2.70
27.69
2.67
25.00
14.52
33.65
9.72
1577
3.28
33.65
2.96
27.50
17.32
40.13
10.69
1735
3.92
40.13
3.26
30.00
20.35
47.14
11.66
1893
4.60
47.14
3.56
32.50
23.60
54.67
12.64
2050
5.34
54.67
3.85
35.00
27.07
62.70
13.61
2208
6.12
62.70
415
37.50
30.76
71.24
14.58
2366
6.96
71.24
4.44
40.00
34.66
80.27
15.55
2523
7.84
80.27
4.74
42.50
38.78
89.80
16.52
2681
8.77
89.80
5.04
45.00
43.11
99.81
17.50
2839
9.75
1 99.81
5.33
47.50
47.65
11031
18.47
2997
10.78
110.31
5.63
50.00
52.40
121.29
19.44
3154
11.85
121.29
5.93
52.50
57.36
132.75
20.41 1
3312
12.97
132.75
6.22
55.00
62.52
144.68
21.38
1 3470
14.14
144.68
6.52
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
' COPPER " 1 1 AND FRICTION LOSS 11 FEET
Maximum O.D. = 1.1265 inches (28.613 mm) Nominal O.D. = 1.1250 inches (28.575 mm)
Minimum O.D. = 1.1235 inches (28.537 mm) Nominal I.D. = 1.0558 inches (26.797 mm)
Nominal Wall Thickness = 0.0350 inches (0.889 mm) Flow Area = 0.8742 sq. inches (563.98 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m
Head Loss
(m /100 m)
Velocity
(m /sec.)
2.50
0.18
0.41
0.92
158
0.04
0.41
0.28
5.00
0.64
1.49
1.84
315
0.14
1.49
0.56
7.50
1.36
3.15
2.75
473
0.31
3.15
0.84
10.00
2.31
5.37
167
631
0.52
5.37
1.12
12.50
149
8.11
4.59
789
0.79
8.11
1.40
15.00
4.90
11.36
5.51
946
1.11
11.36
1.68
17.50
6.52
15.11
6.42
1104
1.47
15.11
1.96
20.00
8.34
19.35
7.34
1262
1.89
19.35
2.24
22.50
10.38
24.06
8.26
1419
2.35
24.06
2.52
25.00
12.61
29.24
9.18
1577
2.85
29.24
2.80
27.50
15.05
34.88
10.09
1735
3.40
34.88
3.08
30.00
17.68
40.97
11.01
1893
4.00
40.97
3.36
32.50
20.51
47.51
11.93
2050
4.64
47.51
3.64
35.00
23.52
54.49
12.85
2208
5.32
54.49
3.92
37.50
2633
61.91
13.76
2366
605
61.91
4.19
40.00
30.12
69.76
14.68
2523
6.81
69.76
4.47
42.50
33.70
78.04
15.60
2681
7.62
78.04
4.75
45.00
37.47
86.74
16.52
2839
8.47
86.74
5.03
47.50
41.41
95.87
17.43
2997
9.37
95.87
5.31
50.00
45.54
105.41
18.35
3154
10.30
105.41
5.59
52.50
49.84
115.37
19.27
3312
11.28
115.37
5.87
55.00
54.33
125.74
20.19
3470
12.29
125.74
6.15
COPPER " 1 1 AND FRICTION LOSS 11 FEET
Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.3750 inches (34.925 mm)
Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.2450 inches (31.623 mm)
Nominal Wall Thickness = 0.0650 inches (1.651 mm) Flow Area = 1.2174 sq. inches (785.41 sq mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m
Head Loss
(m /100 m)
Velocity
(m /sec.)
5.00
0.29
0.67
1.32
315
0.06
0.67
0.40
10.00
1.03
2.40
2.64
631
0.23
2.40
0.80
15.00
2.19
5.08
3.95
946
0.49
5.08
1.20
20.00
3.73
8.65
5.27
1262
0.84
8.65
1.61
25.00
5.64
13.06
6.59
1577
1.27
13.06
2.0
30.00
7.90
18.30
7.91
1893
1.79
18.30
2.41
35.00
10.51
24.34
9.22
2208
2.38
24.34
2.81
40.00
13.46
31.17
10.54
2523
3.04
31.17
3.21
45.00
16.74
38.75
11.86
2839
3.79
38.75
3.61
50.00
20.35
47.09
13.18
3154
4.60
47.09
4.02
55.00
24.27
56.18
14.49
3470
5.49
56.18
4.42
60.00
28.52
65.99
15.81
3785
6.45
1 65.99
4.82
65.00
33.07
76.52
17.13
4101
7.48
76.52
5.22
70.00
37.94
87.76
18.45
4416
8.58
87.76
5.62
75.00
43.11
99.71
19.77
4732
9.75
99.71
6.02
80.00
48.58
112.35
21.08
5047
10.99
112.35
6.43
U.S. customary units in this document are the standard; the metric units are provided for
reference only The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. - ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
COPPER WATER AND FRICTION LOSS PER 100 FEET
Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.375 inches (34.925 mm)
Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.265 inches (32.131 mm)
Nominal Wall Thickness = 0.0550 inches (1.397 mm) Flow Area = 1.2568 sq. inches (810.85 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
5.00
026
0.62
1.28
315
0.06
0.62
0.39
10.00
0.96
2.22
2.55
631
0.22
2.22
0.78
15.00
2.02
4.70
3.83
946
0.46
4.70
1.17
20.00
3.45
8.00
5.11
1262
0.78
8.00
1.56
25.00
5.22
12.09
6.38
1577
1.18
12.09
1.95
30.00
7.31
16.94
7.66
1893
1.65
16.94
2.33
35.00
9.73
22.53
8.93
2208
2.20
22.53
2.72
40.00
12.45
28.84
10.21
2523
2.82
28.84
3.1
45.00
15.49
35.86
11.49
2839
3.50
35.86
3.50
50.00
18.83
43.58
12.76
3154
4.26
43.58
3.89
55.00
22.46
51.98
14.04
3470
5.08
51.98
4.28
60.00
26.39
61.06
15.32
3785
5.97
61.06
4.67
65.00
30.61
70.81
16.59
4101
6.92
70.81
5.D6
70.00
35.11
81.21
17.87
4416
7.94
81.21
5.45
75.00
39.89
92.27
19.15
4732
9.02
92.27
5.84
80.00
44.96
103.97
20.42
5047
10.17
103.97
6.22
Hazen Williams Formula
Maximum O.D. = 1.3765 inches (34.963 mm) Nominal O.D. = 1.3750 inches (34.925 mm)
Minimum O.D. = 1.3735 inches (34.887 mm) Nominal I.D. = 1.2910 inches (32.7914 mm)
Nominal Wall Thickness = 0.0420 inches (1.061 mm) Flow Area = 1.3090 sq, inches (844.52 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/ 100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.
5.00
0.24
0.56
1.23
315
0.05
0.56
0.37
10.00
0.87
2.01
2.45
631
0.20
2.01
0.75
15.00
1.83
4.26
3.68
946
0.41
4.26
1.12
20.00
3.12
7.25
4.90
1262
0.71
7.25
1.49
25.00
4.72
10.95
6.13
1577
1.07
10.95
1.87
30.00
6.62
15.34
7.35
1893
1.50
15.34
2.24
35.00
8.81
20.40
8.58
2208
1.99
20.40
2.61
40.00
11.28
26.12
9.80
2523
2.55
26.12
2.99
45.00
14.03
32.48
11.03
2839
3.17
32.48
3.36
50.00
17.05
39.47
12.25
3154
3.86
39.47
3.74
55.00
20.34
47.08
13.48
3470
4.60
47.08
4.11
60.00
23.90
55.31
14171
1 3785
5.41
55.31
4.48
65.00
27.72
64.14
15.93
4101
6.27
64.14
4.86
70.00
31.80
73.56
17.16
4416
7.19
73.56
5.23
75.00
36.13
83.57
18.38
4732
8.17
83.57
5.60
80.00
40.72
94.17
19.61
5047
9.21
94.17
5.98
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Hazen Williams Formula
Maximum O.D. = 1.6270 inches (41.326 mm) Nominal O.D = 1.6250 inches (41.275 mm)
Minimum O.D. = 1.6230 inches (41.224 mm) Nominal I.D. = 1.4810 inches (38.227 mm)
Nominal Wall Thickness = 0.0720 inches (1.829 mm) Flow Area = 1.7227 sq. inches (1111.39 sq, mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m/sec .)
5.00
0.12
019
0.93
315
0.03
0.29
0.28
10.00
0.44
1.03
1.86
631
0.10
1.03
0.57
15.00
0.94
2.18
2.79
946
0.21
2.18
0.85
20.00
1.60
3.72
3.72
1262
0.36
3.72
1.14
25.00
2.42
5.61
4.66
1577
0.55
5.61
1.42
30.00
3.39
7.87
5.59
1893
0.77
7.87
1.70
35.00
4.52
10.46
6.52
2208
1.02
10.46
1.99
40.00
5.78
13.39
7.45
2523
1.31
13.39
2.27
45.00
7.19
16.65
838
2839
1.63
16.65
2.55
50.00
8.74
20.24
931
3154
1.98
20.24
2.84
55.00
10.43
24.14
10.24
3470
2.36
24.14
3.12
60.00
12.26
28.36
11.17
3785
2.77
28.36
3.41
65.00
14.21
32.88
12.11
4101
3.22
32.88
3.69
70.00
16.30
37.72
13.04
4416
3.69
37.72
3.97
75.00
18.53
42.85
13.97
4732
4.19
42.85
4.26
80.00
20.88
48.28
14.90
5047
4.72
48.28
4.54
85.00
23.36
54.01
15.83
5362
5.28
54.01
4.83
90.00
25.97
60.04
16.76
5678
5.87
60.04
5.11
95.00
28.70
66.35
17.69
5993
6.49
66.35
5.39
100.00
31.56
72.96
18.62
6309
7.14
72.96
5.68
105.00
34.55
79.85
19.56
6624
7.82
79.85
5.96
110.00
37.66
87.03
20.49
6940
8.52
87.03
6.24
115.00
40.89
1 94.49
1 21.42
7255
1 9.25
1 94.49
1 6.53
COPPER 1 1 FRICTION LOSS II FEET
Maximum O.D. = 1.6270 inches (41.326 mm) Nominal O.D. = 1.6250 inches (41.275 mm)
Minimum O.D. = 1.6230 inches (41.224 mm) Nominal I.D. = 1.5050 inches (37.6174 mm)
Nominal Wall Thickness = 0.0600 inches (1.524 mm) Flow Area = 1.7789 sq. inches (1147.71 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
VelX
(m /sec.)
5.00
0.11
0.26
0.90
315
0.03
0.26
0.27
10.00
0.41
0.95
1.80
631
0.09
0.95
0.55
15.00
0.87
2.02
2.71
946
0.20
2.02
0.82
20.00
1.48
3.44
3.61
1262
0.34
3.44
1.10
25.00
2.24
519
4.51
1577
0.51
519
1.37
30.00
3.14
7.27
5.41
1893
0.71
7.27
1.65
35.00
4.18
9.67
6.31
2208
0.94
9.67
1.92
40.00
5.35
12.39
7.21
2523
1.21
12.39
2.20
45.00
6.65
15.40
8.12
2839
1.50
15.40
2.47
50.00
8.09
18.72
9.02
3154
1.83
18.72
2.75
55.00
9.65
22.32
9.92
3470
2.18
22.32
3.02
60.00
11.33
26.22
10.82
3785
2.56
26.22
3.30
65.00
13.14
30.41
11.72
4101
2.97
30.41
3.57
70.00
15.08
34.88
12.62
4416
3.41
34.88
3.85
75.00
17.13
39.63
13.53
4732
3.88
39.63
4.12
80.00
19.31
44.65
14.43
5047
4.37
44.65
4.40
85.00
21.60
49.95
15.33
5362
4.89
49.95
4.67
90.00
24.01
55.52
16.23
5678
5.43
55.52
4.95
95.00
26.54
61.36
17.13
5993
6.00
61.36
5.22
100.00
29.19
67.47
18.03
6309
6.60
67.47
5.50
105.00
31.95
73.84
18.94
6624
7.23
73.84
5.77
110.00
34.82
80.48
19.84
6940
7.88
80.48
6.05
115.00
1 37.81
1 87.38
1 20.74
7255
1 8.55
1 87.38
6.32
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234,0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Hazen Williams Formula
Maximum O.D. = 1.6270 inches (41.326 mm) Nominal O.D. = 1.6250 inches (41.275 mm)
Minimum O.D. = 1.6230 inches (41.224 mm) Nominal I.D. = 1.5270 inches (38.7858 mm)
Nominal Wall Thickness = 0.0490 inches (1.2446 mm) Flow Area = 1.8313 sq. inches (1181.50 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
5.00
0.11
0.25
0.88
315
0.02
0.25
0.27
10.00
0.38
0.89
1.75
631
0.09
0.89
0.53
15.00
0.81
1.88
2.63
946
0.18
1.88
0.80
20.00
1.38
3.20
350
1262
0.31
3.20
1.07
25.00
2.09
4.84
4.38
1577
0.47
4.84
1.33
30.00
2.93
6.78
5.26
1893
0.66
6.78
1.60
35.00
3.89
9.02
6.13
2208
0.88
9.02
1.87
40.00
4.98
11.54
7.01
2523
1.13
11.54
2.14
45.00
6.20
14.35
7.88
2839
1.40
14.35
2.40
%00
7.53
17.44
8.76
3154
1.70
17.44
2.67
55.00
8.99
20.80
9.64
3470
2.03
20.80
2.94
60A0
10.56
24.44
10.51
3785
2.39
24.44
3.20
65.00
12.25
28.34
11.39
4101
237
28.34
3.47
70.00
14.05
32.50
12.26
4416
3.18
32.50
3.74
75.00
15.96
36.92
13.14
4732
3.61
36.92
4.00
80A0
17.99
41.61
14.02
5047
4.07
41.61
4.27
85.00
20.13
46.55
14.89
5362
4.55
46.55
4.54
90.00
22.38
51.74
15.77
5678
5.06
51.74
4.81
95.00
24.73
57.18
16.64
5993
5.59
57.18
5.07
100.00
27.20
62.87
17.52
6309
6.15
62.87
5.34
105.00
2937
68.81
18.40
6624
6.73
68.81
5.61
110.00
32.45
74.99
19.27
6940
7.34
74.99
5.87
115.00
35.23
1 81.42
1 20.15 1
7255
7.97
1 81.42
1 6.14
Hazen Williams Formula
Maximum O.D. = 2.1270 inches (54.026 mm) Nominal O.D. = 2.1250 inches (53.975 mm)
Minimum O.D. = 2.1230 inches (53.924 mm) Nominal I.D. = 1.9590 inches (49.7586 mm)
Nominal Wall Thickness = 0.0830 inches (2.1082 mm) Flow Area = 3.0141 sq. inches (1944.58 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(1kPa /100 m)
Head Loss
(m /100 m)
Velocit
(m /sec
10
0.11
0.26
1.06
631
0.03
0.26
0.32
20
0.41
0.95
2.13
1262
0.09
0.95
0.65
30
0.87
2.02
3.19
1893
0.20
2.02
0.97
40
1.48
3.43
4.26
2523
0.34
3.43
1.30
50
2.24
5.19
5.32
3154
0.51
519
1.62
60
3.14
7.27
639
3785
0.71
7.27
1.95
70
4.18
9.67
7.45
4416
0.95
9.67
2.27
80
5.35
12.38
8.52
5047
1.21
12.38
2.60
90
6.66
15.39
9.58
5678
1.51
15.39
2.92
100
8.09
18.71
10.64
6309
1.83
18.71
3.24
110
9.66
22.32
11.71
6940
218
22.32
3.57
120
11.34
26.21
12.77
7570
2.57
26.21
3.89
130
13.16
30.40
13.84
8201
2.98
30.40
4.22
140
15.09
34.86
100
8832
3.41
34.86
4.54
150
17.15
39.61
15.97
9463
3.88
39.61
4.87
160
1933
44.63
17.03
10094
4.37
44.63
5.19
170
21.62
49.93
18.10
10725
4.89
49.93
5.52
180
1 24.04
1 55.50
1 19.16
11356
5.44
55.50
5.84
190
26.57
61.34
20.22
11986
6.01
61.34
6.16
200
29.22
67.44
21.29
1 12617
6.61
67.44
6.49
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Hazen Williams Formula
Maximum O.D. = 2.1270 inches (54.026 mm) Nominal O.D. = 2.1250 inches (53.975 mm)
Minimum O.D. = 2.1230 inches (53.924 mm) Nominal I.D. = 1.9850 inches (50.419 mm)
Nominal Wall Thickness = 0.0700 inches (1.778 mm) Flow Area = 3.0946 sq. inches (1996.54 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocit
(m /sec
10
011
0.25
1.04
631
0.02
0.25
0.32
20
039
0.89
2.07
1262
0.09
0.89
0.63
30
0.82
1.89
3.11
1893
0.18
1.89
0.95
40
1.39
3.22
4.15
2523
0.31
3.22
1.26
50
2.10
4.87
518
3154
0.48
4.87
1.58
60
2.95
6.82
6.22
3785
0.67
6.82
1.90
70
3.92
9.07
7.26
4416
0.89
9.07
2.21
80
5.02
11.61
8.29
5047
1.14
11.61
2.53
90
6.24
14.44
9.33
5678
1.41
14.44
2.84
100
7.59
17.55
10.37
6309
1.72
17.55
3.16
110
9.06
20.93
11.40
6940
2.05
20.93
3.48
120
10.64
24.58
12.44
7570
2.41
24.58
3.79
130
12.34
28.51
13.48
8201
2.79
28.51
4.11
140
14.15
32.70
14.51
8832
3.20
32.70
4.42
150
16.08
37.15
15.55
9463
3.64
37.15
4.74
160
18.13
41.86
16.59
10094
4.10
41.86
5.06
170
20.28
1 46.83
1 17.62
10725
4.59
46.83
5.37
180
22.54
52.05
18.66
11356
5.10
52.05
5.69
190
24.92
57.53
19.70
11986
5.64
57.53
6.00
200
27.40
63.25
20.73
12611
1 6.20
63.25
6.32
Hazen Williams Formula
Maximum O.D. = 2.1270 inches (54.026 mm) Nominal O.D. = 2.1250 inches (53.975 mm)
Minimum O.D. = 2.1230 inches (53.924 mm) Nominal I.D. = 2.0090 inches (51.0286 mm)
Nominal Wall Thickness = 0.0580 inches (1.4732 mm) Flow Area = 3.1699 sq. inches (2045.11 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec)
10
0.10
0.23
1.01
631
0.02
0.23
0.31
20
0.36
0.84
2.02
1262
0.08
0.84
0.62
30
0.77
1.78
3.04
1893
0.17
1.78
0.93
40
1.31
3.04
4.05
2523
0.30
3.04
1.23
50
1.98
4.59
5.06
3154
0.45
4.59
1.54
60
2.78
6.43
6.07
3785
0.63
6.43
1.85
70
3.70
8.55
7.08
4416
0.84
8.55
2.16
80
4.74
10.95
8.10
5047
1.07
10.95
2.47
90
5.89
13.62
9.11
5678
1.33
13.62
2.78
100
7.16
16.55
10.12
6309
1.62
16.55
3.08
110
8.54
19.74
11.13
6940
1.93
19.74
3.39
120
10.03
23.19
12.15
7570
2.27
23.19
3.70
130
11.64
26.89
13.16
8201
2.63
26.89
4.01
140
13.35
30.84
14.17
8832
3.02
30.84
4.32
150
15.17
35.04
15.18
9463
3.43
35.04
4.63
160
17.10
39.48
16.19
10094
3.87
39.48
4.94
170
19.13
44.17
17.21
10725
4.33
44.17
5.24
180
21.26
49.09
18.22
11356
4.81
49.09
5.55
190
23.50
54.26
19.23
11986
5.32
54.26
5.86
200
25.84
59.66
20.24
12617
5.85
59.66
6.17
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. - ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Hazen Williams Formula
Maximum O.D. = 2.6270 inches (66.7258 mm) Nominal O.D. = 2.6250 inches (66.675 mm)
Minimum O.D. = 2.6230 inches (66.6242 mm) Nominal I.D. = 2.4350 inches (61.849 mm)
Nominal Wall Thickness = 0.0950 inches (2.413 mm) Flow Area = 4.6568 sq. inches (3004.380 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Veloci
(m ) sec.
20
0.14
0.33
1.38
1262
0.03
0.33
0.42
40
0.51
1.19
2.76
2523
0.12
1.19
0.84
60
1.09
2.52
4.13
3785
0.25
2.52
1.26
80
1.86
4.30
5.51
5047
0.42
4.30
1.68
100
2.81
6.49
6.89
6309
0.64
6.49
2.10
120
3.94
9.10
8.27
7570
0.89
9.10
2.52
140
5.24
12.10
9.65
8832
1.18
12.10
2.94
160
6.71
15.49
11.02
10094
1.52
15.49
3.36
180
8.34
19.26
12.40
11356
1.89
19.26
3.78
200
10.14
23.41
13.78
12617
2.29
23.41
4.20
220
12.10
27.92
15.16
13879
2.74
27.92
4.62
240
14.21
32.79
16.53
15141
3.21
32.79
5.04
260
16.48
38.03
17.91
16403
3.73
38.03
5.46
280
18.91
43.62
19.29
17664
4.28
43.62
5.88
300
21.48
49.55
20.67
18926
4.86
49.55
6.30
320
24.21
55.84
22.05
20188
5.48
55.84
6.72
COPPER 1 AND FRICTION LOSS II FEET
Maximum O.D. = 2.6270 inches (66.7258 mm) Nominal O.D. = 2.6250 inches (66,675 mm)
Minimum O.D. = 2.6230 inches (66.6242 mm) Nominal I.D. = 2.4650 inches (62.611 mm)
Nominal Wall Thickness = 0.0800 inches (2.032 mm) Flow Area = 4.7723 sq. inches (3078.87 sq. mm)
Hazen Williams formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/ 100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
20
0.13
0.31
1.34
1262
0.03
0.31
0.41
40
0.48
1.12
2.69
2523
0.11
1.12
0.82
60
1.03
2.38
4.03
3785
0.23
2.38
1.23
80
1.75
4.05
5.38
5047
0.40
4.05
1.64
100
2.65
6.12
6.72
6309
0.60
6.12
2.05
120
3.71
8.57
8.07
7570
0.84
8.57
2.46
140
4.93
11.40
9.41
8832
1.12
11.40
2.87
160
6.32
14.59
10.76
10094
1.43
14.59
3.28
180
7.86
18.15
12.10
11356
1.78
18.15
3.69
200
9.55
22.05
13.45
12617
2.16
22.05
4.10
220
11.40
26.30
14.79
13879
2.58
26.30
4.51
240
13.39
30.90
16.13
15141
3.03
30.90
4.92
260
15.53
35.83
17.48
16403
3.51
35.83
5.33
280
17.81
41.09
18.82
17664
4.03
41.09
534
300
20.24
46.69
2017 .
18926
4.58
46.69
6.15
320
22.81
52.61
21.51
20188
5.16
52.61
6.56
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS ' 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
COPPER WATER AND f t FEET
Maximum O.D. = 2.6270 inches (66.7258 mm) Nominal O.D. = 2.6250 inches (66.675 mm)
Minimum O.D. = 2.6230 inches (66.6242 mm) Nominal I.D. = 2.4950 inches (63.373 mm)
Nominal Wall Thickness = 0.0650 inches (1.651 mm) Flow Area = 4.8891 sq. inches (3154.27 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
20
0.13
0.29
1.31
1262
0.03
0.29
0.40
40
0.46
1.06
2.62
2523
0.10
1.06
0.80
60
0.97
2.24
3.94
3785
0.22
2.24
1.20
80
1.65
3.82
5.25
5047
0.37
3.82
1.60
100
2.50
5.77
6.56
6309
0.56
5.77
2.00
120
3.50
8.08
7.87
7570
0.79
8.08
2.40
140
4.65
10.75
9.19
8832
1.05
10.75
2.80
160
5.96
13.76
10.50
10094
1.35
13.76
3.20
180
7.41
17.11
11.81
11356
1.68
17.11
3.60
200
9.01
20.79
13.12
12617
2.04
20.79
4.00
220
10.75
24.80
14.44
13879
2.43
24.80
4.40
240
12.62
29.13
15.75
15141
2.86
29.13
4.80
260
14.64
33.78
17.06
16403
3.31
33.78
5.20
280
16.80
38.75
18.37
17664
3.80
38.75
5.60
300
19.09
44.02
19.69
18926
4.32
44.02
6.00
320
21.51
49.60
21.00
20188
4.87
49.60
6.40
Hazen Williams Formula
Maximum O.D. = 3.1270 inches (19.4258 mm) Nominal O.D. = 3.1250 inches (79.375 mm)
Minimum O.D. = 3.1230 inches (79.3242 mm) Nominal I.D. = 2.9070 inches (73.8378 mm)
Nominal Wall Thickness = 0.1090 inches (2.7686 mm) Flow Area = 6.6371 sq. inches (4282.01 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
25
0.09
0.21
1.21
1577
0.02
0.21
0.37
50
0.33
0.76
2.42
3154
0.07
0.76
0.74
75
0.70
1.61
3.63
4732
0.16
1.61
1.11
100
1.19
2.74
4.83
6309
0.27
2.74
1.47
125
1.79
4.14
6.04
7886
0.41
4.14
1.84
150
2.51
5.80
7.25
9463
0.57
5.80
2.21
175
3.34
7.72
8.46
11040
0.76
7.72
2.58
200
4.28
9.88
9.67
12617
0.97
9.88
2.95
225
5.33
12.29
10.88
14195
120
1229
3.32
250
6.47
14.94
12.08
15772
1.46
14.94
3.68
275
7.72
17.82
13.29
17349
1.75
17.82
4.05
300
9.07
20.93
14.50
18926
2.05
20.93
4.42
325
10.52
24.27
15.71
20503
2.38
24.27
4.79
350
12.07
27.83
16.92
22080
2.73
27.83
5.16
375
13.72
31.62
1813
23658
3.10
31.62
5.53
400
15.46
35.63
1 19.34
25235
3.50
35.63
5.89
425
17.29
39.86
1 20.54
26812
3.91
39.86
1 6.26
U.S. customary units in this document are the standard; the metric units are provided for
reference only The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0221
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455
F7/
O.. TUBE WATER ii FEET
Maximum O.D. = 3.1270 inches (79.4258 mm) Nominal O.D. = 3.1250 inches (79.375 mm)
Minimum O.D. = 3.1230 inches (79.3242 mm) Nominal I.D. = 2.9450 inches (74.803 mm)
Nominal Wall Thickness = 0.0900 inches (2.286 mm) Flow Area = 6.8118 sq. inches (4394.69 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ful00 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m/sec .)
25
0.09
0.20
1.18
1577
0.02
020
0.36
50
0.31
0.71
2.35
3154
0.07
031
0.72
75
0.65
1.51
3.53
4732
0.15
1.51
1.08
100
1.11
2.57
4.71
6309
0.25
2.57
1.44
125
1.68
3.89
5.89
7886
0.38
3.89
1.79
150
2.36
5.45
7.06
9463
0.53
5.45
2.15
175
3.14
7.25
8.24
11040
0.71
7.25
2.51
200
4.02
9.28
9.42
12617
0.91
9.28
2.87
225
5.00
11.54
10.60
14195
1.13
11.54
3.23
250
6.08
14.02
11.77
15772
1.37
14.02
3.59
275
7.25
16.72
12.95
17349
1.64
16.72
3.95
300
8.52
19.65
14.13
18926
1.93
19.65
4.31
325
9.88
22.78
1531
20503
2.23
22.78
4.67
350
11.33
26.13
16.48
22080
2.56
26.13
5.02
375
12.88
29.69
17.66
23658
2.91
29.69
5.38
400
14.51
33.45
18.84
25235
3.28
33.45
5.74
425
1 16.24
1 37.42
1 20.02
1 26812
1 3.67
1 37.42
1 6.10
Hazen Williams Formula
Maximum O.D. = 3.1270 inches Q9.4258 mm) Nominal O.D. = 3.1250 inches (79.375 mm)
Minimum O.D. = 3.1230 inches Q9.3242 mm) Nominal I.D. = 2.9810 inches (75.7174 mm)
Nominal Wall Thickness = 0.0720 inches (1.8288 mm) Flow Area = 6.9793 sq, inches (4502.79 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
25
0.08
0.19
1.15
1577
0.02
0.19
0.35
50
0.29
0.67
2.30
3154
0.07
0.67
0.70
75
0.62
1.42
3.45
4732
0.14
1.42
1.05
100
1.05
2.43
4.60
6309
0.24
2.43
1.40
125
1.59
3.67
5.75
7886
0.36
3.67
1.75
150
2.22
5.14
6.90
9463
0.50
5.14
2.10
175
2.96
6.83
8.04
11040
0.67
6.83
2.45
200
3.79
8.75
9.19
12617
0.86
8.75
2.80
225
4.71
10.88
1034
14195
1.07
10.88
3.15
250
5.73
13.22
11.49
15772
1.30
13.22
3.50
275
6.83
15.76
12.64
17349
1.55
15.76
3.85
300
8.03
18.52
13.79
18926
1.82
18.52
4.20
325
9.31
21.47
14.94
20503
2.11
21.47
4.55
350
10.68
24.63
16.09
22080
2.42
24.63
4.90
375
12.14
27.98
17.24
23658
2.75
27.98
5.25
400
13.68
31.53
18.39
25235
3.09
31.53
5.60
425
1 1530
1 35.27
1 19.54
1 26812
1 3.46
1 35.27
1 5.95
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST- • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
W ATER AND FRICTION LOSS PER 100 FEET
Maximum O.D. = 3.6270 inches (92.1258 mm) Nominal O.D. = 3.6250 inches (92.075 mm)
Minimum O.D. = 3.6230 inches (92.0242 mm) Nominal I.D. = 3.3850 inches (85.979 mm)
Nominal Wall Thickness = 0.1200 inches (3.048 mm) Flow Area = 6.9993 sq. inches (5805.97 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(tt/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
25
0.04
010
0.89
1577
0.01
0.10
0.27
50
0.16
036
1.78
3154
0.04
0.36
0.54
75
0.33
0.77
2.67
4732
0.08
0.77
0.81
100
0.57
1.31
3.57
6309
0.13
1.31
1.09
125
0.85
1.98
4.46
7886
0.19
1.98
1.36
150
1.20
2.77
5.35
9463
0.27
2.77
1.63
175
1.59
3.68
6.24
11040
0.36
3.68
1.90
200
2.04
4.71
7.13
12617
0.46
4.71
2.17
225
2.54
5.86
8.02
14195
0.57
5.86
2.44
250
3.09
7.12
8.91
15772
0.70
7.12
2.72
275
3.68
8.49
9.80
17349
0.83
8.49
2.99
300
4.33
9.98
10.70
18926
0.98
9.98
3.26
325
5.02
11.57
11.59
20503
1.13
11.57
3.53
350
5.76
1127
12.48
22080
1.30
13.27
3.80
375
6.54
15A8
13.37
23658
1.48
15.08
4.07
400
7.37
16.99
14.26
25235
1.67
16.99
4.35
425
8.25
19.01
15.15
26812
1.87
19.01
4.62
450
9.17
21.12
16.04
28389
2.07
21.12
4.89
475
10.13
23.35
16.93
29966
2.29
23.35
5.16
500
11.14
25.67
17.83
31543
2.52
25.67
5.43
525
12.20
28.10
18.72
33121
2.76
28.10
5.70
550
13.29
30.62
19.61
34698
3.01
30.62
5.98
575
1 14.43
33.25
1 20.50
36275
1 3.26
1 33.25
6.25
600
1 15.62
1 35.97
1 21.39
37852
1 3.53 1
35.91 1
6.52
Hazen Williams Formula
Maximum O.D. = 3,6270 inches (92.1258 mm) Nominal O.D. = 3,6250 inches (92.075 mm)
Minimum O.D. = 3.6230 inches (92.0242 mm) Nominal I.D. = 3.4250 inches (86.995 mm)
Nominal Wall Thickness = 0.1000 inches (2.540 mm) Flow Area = 9.2132 sq. inches (5944.00 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m/sec .)
25
0.04
0.09
0.87
1577
0.01
0.09
0.27
50
0.15
0.34
1.74
3154
0.03
0.34
0.53
75
0.31
0.73
2.61
4732
0.07
0.73
0.80
100
0.53
1.23
3.48
6309
0.12
1.23
1.06
125
0.81
1.87
4.35
7886
0.18
1.87
1.33
150
1.13
2.61
5.22
9463
0.26
2.61
1.59
175
1.51
3.48
6.09
11040
0.34
3.48
1.86
200
1.93
4.45
6.96
12617
0.44
4.45
2.12
225
2.40
5.53
7.84
14195
0.54
5.53
239
250
2.91
633
8.71
15772
0.66
6.73
2.65
275
3.48
8,02
9.58
17349
0.79
8.02
2.92
300
4.09
9.42
10.45
18926
0.92
9.42
3.18
325
4.74
10.93
11.32
20503
107
10.93
3.45
350
5.44
12.53
12.19
22080
1.23
12.53
3.71
375
6.18
1424
13.06
23658
1.40
14.24
3.98
400
6.96
16.05
13.93
25235
1.57
16.05
4.25
425
7.79
17.95
14.80
26812
1.76
17.95
4.51
450
8.66
19.95
15.67
28389
1.96
19.95
4.78
475
9.57
22.05
16.54
29966
2.16
22.05
5.04
500
10.52
24.25
1 17.41
31543
2.38
24.25
5.31
525
11.52
26.54
18.28
33121
2.61
26.54
5.57
550
12.55
28.92
19.15
34698
2.84
28.92
5.84
575
13.63
31.40
20.02
36275
3.08
31.40
6.10
600
14.75
33.97
20.89
37852
3.34
33.97
6.37
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
O.. WATER ii FEET
Maximum O.D. = 3.6270 inches (92.1258 mm) Nominal O.D. = 3.6250 inches (92.075 mm)
Minimum O.D. = 3.6230 inches (92.0242 mm) Nominal I.D. = 3.4590 inches (87.8586 mm)
Nominal Wall Thickness = 0.0830 inches (2.1082 mm) Flow Area = 9.397 sq. inches (6062.59 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
25
0.04
0.09
0.85
1577
0.01
0.09
0.26
50
0.14
0.33
1.71
3154
0.03
0.33
0.52
75
0.30
0.69
2.56
4732
0.07
0.69
038
100
0.51
1.18
3.41
6309
0.12
1.18
1.04
125
0.77
1.78
4.27
7886
0.17
1.78
1.30
150
1.08
2.49
5.12
9463
0.24
2.49
1.56
175
1.44
3.31
5.97
11040
0.32
3.31
1.82
200
1.84
4.24
6.83
12617
0.42
4.24
2.08
225
2.29
527
7.68
14195
0.52
5.27
2.34
250
2.78
6.41
8.54
15772
0.63
6.41
2.60
275
3.31
7.65
9.39
17349
0.75
7.65
2.86
300
3.89
8.98
10.24
18926
0.88
8.98
3.12
325
4.52
10.41
11.10
20503
1.02
10.41
3.38
350
5.18
11.94
11.95
22080
1.17
11.94
3.64
375
5.89
13.57
12.80
23658
1.33
13.57
3.90
400
6.63
1529
13.66
25235
1.50
15.29
4.16
425
7.42
17.11
14.51
26812
1.68
17.11
4.42
450
8.25
19.02
15.36
28389
1.87
19.02
4.68
475
9.12
21.02
16.22
29966
2.06
21.02
4.94
500
10.03
23.11
17.07
31543
2.27
23.11
5.20
525
10.98
25.29
17.92
33121
2.48
25.29
5.46
550
11.96
27.56
18.78
34698
2.71
27.56
5.72
575
12.99
29.93
19.63
36275
2.94
29.93
5.98
600
1 14.06
1 32.38
20.49
1 37852
1 3.18
32.38
6.24
Hazen Williams Formula
Maximum O.D. = 4.1270 inches (104.8258 mm) Nominal O.D. = 4.1250 inches (104.775 mm)
Minimum O.D. = 4.1230 inches (104.7242 mm) Nominal I.D. = 3.8570 inches (97.9678 mm)
Nominal Wall Thickness = 0.1340 inches (3.4036 mm) Flow Area = 11.6839 sq. inches 0538.01 sq, mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
50
0.08
0.19
1.37
3154
0.02
0.19
0.42
100
0.30
0.69
2.75
6309
0.07
0.69
0.84
150
0.63
1.47
4.12
9463
0.14
1.47
1.26
200
1.08
2.50
5.49
12617
0.24
2.50
1.67
250
1.64
3.77
6.86
15772
0.37
3.77
2.09
300
2.29
5.29
8.24
18926
0.52
5.29
2.51
350
3.05
7.03
9.61
22080
0.69
7.03
2.93
400
3.91
9.00
10.98
25235
0.88
9.00
3.35
450
4.86
11.19
12.36
28389
1.10
11.19
3.77
500
5.90
1160
13.73
31543
1.34
13.60
4.18
550
7.04
16.23
15.10
34698
1.59
1623
4.60
600
8.27
19.06
16.48
37852
1.87
19.06
5.02
650
9.60
22.10
17.85
41006
2.17
22.10
5.44
700
11.01
25.35
19.22
44161
2.49
25.35
5.86
750
12.51
28.80
20.59
47315
2.83
28.80
6.28
800
14.10
32.45
21.97
50469
3.19
32.45
6.70
850
15.77
36.30
23.34
53624
3.57
36.30
7.11
900
1 17.53
1 40.35
24.71
56778
3.97
40.35
7.53
950
19.38
44.60
26.09
59932
4.38
44.60
7.95
1000
2131
49.04
1 27.46
63087
1 4.82
4904
8.37
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST- • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Hazen Williams Formula
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/ 100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
50
0.08
0.18
1.34
3154
0.02
0.18
0.41
100
028
0.65
2.68
6309
0.06
0.65
0.82
150
0.60
1.38
4.02
9463
0.14
1.38
1.22
200
1.02
2.35
536
12617
0.23
2.35
1.63
250
1.54
3.55
630
15772
0.35
155
2.04
300
2.16
4.98
8.04
18926
0.49
4.98
2.45
350
2.87
6.62
9.38
22080
0.65
6.62
2.86
400
3.68
8.48
10.72
25235
0.83
8.48
3.27
450
4.57
10.54
12.05
28389
1.03
10.54
3.67
500
5.56
12.81
13.39
31543
1.26
12.81
4.08
550
6.63
1528
14.73
34698
1.50
15.28
4.49
600
7.79
17.95
16.07
37852
1.76
17.95
4.90
650
9.04
20.81
17.41
41006
2.04
20.81
5.31
700
10.37
2187
18.75
44161
2.34
23.87
5.72
750
11.78
2712
20.09
47315
2.66
27.12
6.12
800
13.27
30.56
21.43
50469
3.00
30.56
6.53
850
14.85
1 34.18
1 22.77
53624
3.36
1 34.18
1 6.94
900
16.51
38.00
24.11
56778
3.73
38.00
7.35
950
18.25
41.99
25.45
59932
4.13
41.99
7.76
1000
20.07
46.17
26.79
63087
4.54
46.17
8.17
Hazen Williams Formula
Maximum O.D. = 4.1270 inches (104.8258 mm) Nominal O.D = 4.1250 inches (104.775 mm)
Minimum O.D. = 4.1230 inches (104.7242 mm) Nominal I.D. = 3.9050 inches (99.187 mm)
Nominal Wall Thickness = 0.1100 inches (2.794 mm) Flow Area = 11.9766 sq. inches (7726.80 sq. mm)
C Factor = 150
Maximum O.D. = 4.1270 inches (104.8258 mm) Nominal O.D. = 4.1250 inches (104.775 mm)
Minimum O.D. = 4.1230 inches (104.7242 mm) Nominal I.D. = 3.9350 inches (99.949 mm)
Nominal Wall Thickness = 0.0950 inches (2.413 mm) Flow Area = 12.1613 sq, inches (1845.87 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m ) sec.)
50
0.08
0.17
1.32
3154
0.02
0.17
0.40
100
0.27
0.63
2.64
6309
0.06
0.63
0.80
150
0.58
1.33
3.96
9463
0.13
1.33
1.21
200
0.98
2.27
5.28
12617
0.22
2.27
1.61
250
1.48
3.42
6.60
15772
0.34
3.42
2.01
300
2.08
4.80
7.91
18926
0.47
4.80
2.41
350
2.77
6.38
9.23
22080
0.63
6.38
2.81
400
3.54
817
10.55
25235
0.80
8.17
3.22
450
4.41
10.15
11.87
28389
1.00
10.15
3.62
500
536
12.34
13.19
31543
1.21
12.34
4.02
550
6.39
14.72
14.51
34698
1.45
14.72
4.42
600
7.51
17.29
15.83
37852
1.70
17.29
4.82
650
8.71
20.05
17.15
41006
1.97
20.05
5.23
700
9.99
23.00
18.47
44161
2.26
23.00
5.63
750
11.35
26.13
19.79
47315
2.57
26.13
6.03
800
12.79
29.44
2111
50469
2.89
29.44
6.43
850
14.31
1 32.93
1 22.42
53624
3.24
32.93
6.83
900
15.91
36.61
23.74
56778
3.60
36.61
7.24
950
17.58
40.46
25.06
59932
3.98
40.46
7.64
1000
19.33
44.49
26.38
63087
431
44.49
8.04
U.S. customary units in this document are the standard; the metric units are provided for
reference only The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
COPPER WATER FLOW AND FRICTION LOSS PER 100 FEET
Maximum O.D. = 5.1270 inches (130.2258 mm) Nominal O.D. = 5.1250 inches (130.175 mm)
Minimum O.D. = 5.1230 inches (130.1242 mm) Nominal I.D. = 4.8050 inches (122.047 mm)
Nominal Wall Thickness = 0.1600 inches (4.064 mm) Flow Area = 18.1333 sq. inches (11698.87 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(rt/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(M/s
50
0.03
0.07
0.88
3154
0.01
0.07
0.27
100
0.10
0.24
1.77
6309
0.02
0.24
0.54
150
0.22
0.50
2.65
9463
0.05
0.50
0.81
200
0.37
0.86
3.54
12617
0.08
0.86
1.08
250
0.56
1.30
4.42
15772
0.13
1.30
1.35
300
0.79
1.81
5.31
18926
0.18
1.81
1.62
350
1.05
2.41
6.19
22080
0.24
2.41
1.89
400
1.34
3.09
7.08
25235
0.30
3.09
2.16
450
1.67
3.84
7.96
28389
0.38
3.84
2.43
500
2.03
4.67
8.85
31543
0.46
4.67
2.70
550
2.42
5.57
9.73
34698
0.55
5.57
2.9
600
2.84
6.54
10.62
37852
0.64
6.54
3.24
650
3.29
7.59
11.50
41006
0.75
7.59
3.51
700
3.78
8.70
12.39
44161
0.85
8.70
3.77
750
4.29
9.89
13.27
47315
0.97
9.89
4.04
800
4.84
11.14
14.15
50469
1.09
11.14
4.31
850
5.41
12.46
15.04
53624
1.22
12.46
4.58
900
6.02
13.85
15.92
56778
1.36
13.85
4.85
950
6.65
15.31
16.81
59932
1.50
15.31
5.12
1000
7.32
16.83
17.69
63087
1.65
16.83
5.39
1050
8.01
18.42
18.58
66241
1.81
18.42
5.66
1100
8.73
20.08
19.46
69395
1.97
20.08
5.93
1150
1 9.48 1
21.80
20.35 1
72550
1 2.14
21.80
1 6.20
Hazen Williams Formula
Maximum O.D. = 5.1270 inches (130.2258 mm) Nominal O.D. = 5.1250 inches (130.175 mm)
Minimum O.D. = 5.1230 inches (130.1242 mm) Nominal I.D. = 4.8750 inches (123.825 mm)
Nominal Wall Thickness = 0.1250 inches (3.175 mm) Flow Area = 18.6655 sq. inches (12042.22 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
50
0.03
0.06
0.86
3154
0.01
0.06
0.26
100
0.10
0.22
1.72
6309
0.02
0.22
0.52
150
0.20
0.47
2.58
9463
0.05
0.47
0.79
200
0.35
0.80
3.44
12617
0.08
0.80
1.05
250
0.52
1.21
4.30
15772
0.12
1.21
1.31
300
0.73
1.69
5.16
18926
0.17
1.69
1.57
350
0.98
2.25
6.02
22080
0.22
2.25
1.83
400
1.25
2.88
6.88
25235
0.28
2.88
2.10
450
1.55
3.58
7.73
28389
0.35
3.58
2.36
500
1.89
4.35
8.59
31543
0.43
4.35
2.62
550
2.25
5.19
9.45
34698
0.51
5.19
2.88
600
2.65
6.10
10.31
37852
0.60
6.10
3.14
650
3.07
7.07
11.17
41006
0.69
7.07
3.41
700
3.52
8.11
12.03
44161
0.80
8.11
3.67
750
4.00
9.21
12.89
47315
0.91
9.21
3.93
800
4.51
10.38
13.75
50469
1.02
10.38
4.19
850
5.05
11.61
14.61
53624
1.14
11.61
4.45
900
5.61
12.91
15.47
56778
1.27
12.91
4.72
950
6.20
14.27
16.33
59932
1.40
14.27
4.98
1000
6.82
15.69
17.19
63087
1.54
15.69
524
1050
7.46
17.17
18.05
66241
1.69
17.17
5.50
1100
8.13
18.71
18.91
69395
1.84
18.71
5.76
1150
8.83
20.32
19.77
72550
1 2.00
1 20.32
1 6.02
U.S. customary units in this document are the standard; the metric units are provided for
reference only The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
O.. AND ii FEET
Maximum O.D. = 5.1270 inches (130.2258 mm) Nominal O.D. = 5.1250 inches (130.175 mm)
Minimum O.D. = 5.1230 inches (130.1242 mm) Nominal I.D. = 4.9070 inches (124.6378 mm)
Nominal Wall Thickness = 0.1090 inches (2.1686 mm) Flow Area = 18.9113 sq. inches (12200.83 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m/sec.
50
0.03
0.06
0.85
3154
0.01
0.06
0.26
100
0.09
0.21
1.70
6309
0.02
0.21
0.52
150
0.20
0.45
2.54
9463
0.04
0.45
0.78
200
0.34
0.77
3.39
12617
0.08
0.77
1.03
250
0.51
1.17
4.24
15772
0.11
1.17
1.29
300
0.71
1.64
5.09
18926
0.16
1.64
1.55
350
0.95
2.18
5.94
22080
0.21
2.18
1.81
400
1.21
2.79
1 6.79
25235
0.27
2.79
2.07
450
1.51
3.47
7.63
28389
0.34
3.47
2.33
500
1.83
4.22
8.48
31543
0.41
4.22
2.59
550
2.18
5.03
9.33
34698
0.49
5.03
2.84
600
2.56
5.91
10.18
37852
0.58
5.91
3.10
650
2.97
6.85
11.03
41006
0.67
6.85
3.36
700
3.41
7.86
11.88
44161
0.77
7.86
3.62
750
3.88
8.93
1232
47315
0.88
8.93
3.88
800
4.37
10.06
1157
50469
0.99
10.06
4.14
850
4.89
11.25
14.42
53624
1.11
11.25
4.40
900
5.43
12.51
15.27
56778
1.23
12.51
4.65
950
6.01
13.82
16.12
59932
1.36
13.82
4.91
1000
6.60
15.20
16.97
63087
1.49
15.20
5.17
1050
7.23
16.63
1 17.81
66241
1.64
16.63
5.43
1100
7.88
18.13
18.66
69395
1.78
18.13
5.69
1150 1
8.56
19.68 1
19.51
72550
1.94
19.68
5.95
Hazen Williams Formula
Maximum O.D. = 6.1270 inches (155.6258 mm) Nominal O.D. = 6.1250 inches (155.575 mm)
Minimum O.D. = 6.1230 inches (155.5242 mm) Nominal I.D. = 5.7410 inches (145.8214 mm)
Nominal Wall Thickness = 0.1920 inches (4.8768 mm) Flow Area = 25.8860 sq. inches (16700.61 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
100
0.04
0.10
124
6309
0.01
0.10
0.38
200
0.16
0.36
2.48
12617
0.04
0.36
0.76
300
0.33
036
3.72
18926
0.07
0.76
1.13
400
0.56
1.30
4.96
25235
0.13
1.30
1.51
500
0.85
1.96
6.20
31543
0.19
1.96
1.89
600
1.19
235
7.44
37852
0.27
2.75
2.27
700
1.59
3.66
8.68
44161
0.36
3.66
2.64
800
2.04
4.69
9.92
50469
0.46
4.69
3.02
900
2.53
5.83
11.15
56778
0.57
5.83
3.40
1000
3.08
7.08
12.39
63087
0.70
7.08
3.78
1100
3.67
8.45
13.63
69395
0.83
8.45
4.16
1200
4.31
9.92
14.87
75704
0.98
9.92
4.53
1300
5.00
11.50
16.11
82013
1.13
11.50
4.91
1400
5.74
13.19
17.35
88321
1.30
13.19
5.29
1500
6.52
14.99
18.59
94630
1.47
14.99
5.67
1600
7.35
16.89
19.83
100939
1.66
16.89
6.04
1700
1 8.22
18.90
1 21.07
107247
1 1.86
1 18.90
6.42
1800
1 9.14
1 21.00
1 22.31
1 113556
1 2.07
1 21.00
1 6.80
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST ^ . ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
' COPPER " 1 AND FRICTION LOSS 11 FEET
Maximum O.D. = 6.1270 inches (155.6258 mm) Nominal O.D. = 6.1250 inches (155.575 mm)
Minimum O.D. = 6.1230 inches (155.5242 mm) Nominal I.D. = 5.8450 inches (148.463 mm)
Nominal Wall Thickness = 0.1400 inches (3.556 mm) Flow Area = 26.8324 sq. inches (17311.17 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
100
0.04
0.09
1.20
6309
0.01
0.09
0.36
200
014
0.33
2.39
12617
0.03
0.33
0.
300
0.30
0.70
3.59
18926
0.07
0.70
1.0
400
0.52
1.19
4.78
25235
0.12
1.19
1.46
500
0.78
1.80
5.98
31543
0.18
1,80
1.82
600
1.09
2.52
7.17
37852
025
2.52
2.19
700
1.46
3.35
8.37
44161
0.33
3.35
2.
800
1.87
4.29
9.57
50469
0.42
4.29
2.
900
2.32
5.34
10.76
56778
0.52
5.34
3.28
1000
2.82
6.49
11.96
63087
0.64
6.49
3.6
1100
3.36
7.74
13.15
69395
0.76
7.74
4.01
1200
3.95
9.09
14.35
75704
0.89
9.09
4.37
1300
4.58
10.54
15.54
82013
1.04
10.54
4.74
1400
5.26
12.09
16.74
88321
1.19
12.09
5.10
1500
5.98
13.74
17.94
94630
1.35
13.74
5.47
1600
6.73
15.48
19.13
100939
1.52
15.48
5.83
1700
1 7.53 1
17.32
20.33
107247
1 1.70
17.32
1 6.20
1800
1 8.38 1
19.25 1
21.52
113556
1 1.89
1 19.25
1 6.56
Hazen Williams Formula
Maximum O.D. = 6.1270 inches (155.6258 mm) Nominal O.D. = 6.1250 inches (155.575 mm)
Minimum O.D. = 6.1230 inches (155.5242 mm) Nominal I.D. = 5.8810 inches (149.3774 mm)
Nominal Wall Thickness = 0.1220 inches (3.0988 mm) Flow Area = 27.1639 sq. inches (17525.07 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocit
(m /sec
100
0.04
0.09
1.18
6309
0.01
0.09
0.36
200
0.14
0.32
2.36
12617
0.03
0.32
0.72
300
0.29
0.68
3.54
18926
0.07
0.68
1.08
400
0.50
1.16
4.72
25235
0.11
1.16
1.44
500
0.76
1.75
5.91
31543
0.17
1.75
1.80
600
1,06
2.45
7.09
37852
0.24
2.45
2.16
700
1.41
3.26
8.27
44161
0.32
3.26
2.52
800
1.81
417
9.45
50469
0.41
4.17
2.88
900
2.25
518
10.63
56778
0.51
5.18
3.24
1000
2.74
6.30
11.81
63087
0.62
6.30
3.60
1100
3.27
7.51
12.99
69395
0.74
7.51
3.96
1200
3.84
8.82
14.17
75704
0.87
8.82
4.32
1300
4.45
10.23
15.35
82013
1.01
10.23
4.68
1400
5.10
11.74
16.54
88321
1.15
11.74
5.04
1500
5.80
13.33
1732
94630
1.31
13.33
5.40
1600
6.54
15.02
18.90
100939
1.48
15.02
5.76
1700
7.31
16.81
20.08
107247
1.65
16.81
6.12
1800
1 813
18.68
1 21.26
1 113556
1 1.84
1 18.68
1 6,48
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Hazen Williams Formula
Maximum O.D. = 8.1270 inches (206.4258 mm) Nominal O.D. = 8.1240 inches (206.3496 mm)
Minimum O.D. = 8.1210 inches (206.2734 mm) Nominal I.D. = 7.5820 inches (192.5828 mm)
Nominal Wall Thickness = 0.2710 inches (6.8834 mm) Flow Area = 45.1500 sq, inches (29128.95 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(Psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m/100 m)
Velocity
(m /sec
200
0.04
0.09
1.42
12617
0.01
0.09
0.43
400
0.15
0.34
2.84
25235
0.03
0.34
0.87
600
0.31
0.71
4.26
37852
0.07
0.71
1.30
800
0.53
1.21
5.68
50469
0.12
1.21
1.73
1000
0.80
1.83
7.11
63087
0.18
1.83
2.17
1200
1.11
2.56
8.53
75704
0.25
2.56
2.60
1400
1.48
3.41
9.95
88321
0.34
3.41
3.03
16W
1.90
4.36
11.37
100939
0.43
4.36
3.47
1800
2.36
5.43
12.79
113556
0.53
5.43
3.90
2000
2.87
6.60
14.21
126173
0.65
6.60
4.33
2200
3.42
7.87
15.63
138791
0.77
7.87
4.76
2400
4.02
9.24
17.05
151408
0.91
9.24
5.20
2600
4.67
10.72
18.48
164025
1.06
10.72
5.63
2800
5.35
12.29
19.90
176643
1.21
12.29
6.06
3000
6.08
13.96
21.32
189260
1.38
13.96
6.50
3200
6.85
15.73
22.74
201877
1.55
15.73
6.93
3400
7.67
17.60
1 24.16
1 214495
1 1.73
17.60
1 7.36
3600
8.53
19.57
25.58
227112
1.93
19.57
7.80
3800
9.42
21.62
27.00
239729
2.13
21.62
8.23
4000
10.36
1 23.78
28.42
252347
2.34
1 23.78
8.66
Maximum O.D. = 8.1270 inches (206.4258 mm) Nominal O.D. = 8.1240 inches (206.3496 mm)
Minimum O.D. = 8.1210 inches (206.2734 mm) Nominal I.D. = 7.7240 inches (196.1896 mm)
Nominal Wall Thickness = 0.2000 inches (5.080 mm) Flow Area = 46.8570 sq. inches (30230.26 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(Psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /se
200
0.04
0.09
1.37
12617
0.01
0.09
0.42
400
0.13
0.31
2.74
25235
0.03
0.31
0.83
600
0.28
0.65
4.11
37852
0.06
0.65
1.25
800
0.48
1.11
5.48
50469
0.11
1.11
1.67
1000
0.73
1.67
6.85
63087
0.16
1.67
2.09
1200
1.02
2.34
8.22
75704
0.23
2.34
2.50
1400
1.35
3.12
9.59
88321
0.31
3.12
2.92
1600
1.73
3.99
10.96
100939
0.39
3.99
3.34
1800
2.16
4.96
12.32
113556
0.49
4.96
3.76
2000
2.62
6.03
13.69
126173
0.59
6.03
4.17
2200
3.13
7.19
15.06
138791
0.71
7.19
4.59
2400
3.68
8.44
16.43
151408
0.83
8.44
5.01
2600
4.26
9.79
17.80
164025
0.96
9.79
5.43
2800
4.89
11.23
19.17
176643
1.11
11.23
5.84
3000
5.56
12.76
20.54
189260
1.26
12.76
6.26
3200
6.26
14.38
21.91
201877
1.42
14.38
6.68
3400
7.01
16.08
23.28
214495
1.58
16.08
7.10
3600
7.79
17.88
24.65
227112
1.76
17.88
7.51
3800
8.61
19.76
26.02
239729
1.95
19.76
7.93
4000
9.47
21.72
27.39
252347
2.14
21.72
8.35
Hazen Williams Formula
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Hazen Williams Formula
Maximum O.D = 8.1270 inches (206.4258 mm) Nominal O.D. = 8.1240 inches (206.3496 mm)
Minimum O.D. = 8.1210 inches (206.2734 mm) Nominal I.D. = 7.7840 inches (197.7136 mm)
Nominal Wall Thickness = 0.1700 inches (4.3180 mm) Flow Area = 47.5878 sq. inches (30701.74 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocit
(m /sec
200
0.04
0.08
1.35
12617
0.01
0.08
0.41
400
0.13
0.30
2.70
25235
0.03
0.30
0.82
600
0.27
0.63
4.05
37852
0.06
0.63
1.23
800
0.46
1.07
5.39
50469
0.10
1.07
1.64
1000
0.70
1.61
6.74
63087
0.16
1.61
2.05
1200
0.98
2.26
8.09
75704
0.22
2.26
2.47
1400
1.30
3.00
9.44
88321
0.30
3.00
2.88
1600
1.67
3.84
10.79
100939
0.38
3.84
129
1800
2.08
4.78
12.14
113556
0.47
4.78
3.70
2000
2.53
5.80
13.48
126173
0.57
5.80
4.11
2200
3.01
6.92
14.83
138791
0.68
6.92
4.52
2400
3.54
8.13
16.18
151408
0.80
8.13
4.93
2600
4.11
9.43
17.53
164025
0.93
9.43
5.34
2800
4.71
10.81
18.88
176643
1.07
10.81
5.75
3000
5.35
12.29
20.23
189260
1.21
12.29
6.16
3200
6.03
13.85
21.57
201877
1.36
13.85
6.58
3400
6.75
15.49
22.92
214495
1.53
15.49
6.99
3600
1 7.50
17.22
24.27
227112
1.70
1722
7.40
3800
8.29
1 19.03
1 25.62
239729
1 1.88
1 19.03
1 7.81
4000
912
1 20.92
1 26.97
252347
1 2.06
1 20.92
1 8.22
Hazen Williams Formula
Maximum O.D. = 10.1270 inches (257.2258 mm) Nominal O.D. = 10.1230 inches (257.1242 mm)
Minimum O.D. = 10.1190 inches (257.0226 mm) Nominal I.D. = 9.4470 inches (239.9538 mm)
Nominal Wall Thickness = 0.3380 inches (8,5852 mm) Flow Area = 70.0935 sq. inches (45221.52 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocit
(m /sec.
200
0.01
0.03
0.92
12617
0.00
0.03
0.28
400
0.05
0.12
183
25235
0.01
0.12
0.56
600
0.11
0.24
2.75
37852
0.02
0.24
0.84
800
0.18
0.42
3.66
50469
0.04
0.42
1.12
1000
0.27
0.63
4.58
63087
0.06
0.63
1.40
1200
0.38
0.88
5.49
75704
0.09
0.88
1.67
1400
0.51
1.17
6.41
88321
0.12
1.17
1.95
1600
0.65
1.50
7.32
100939
0.15
1.50
2.23
1800
0.81
1.86
8.24
113556
0.18
1.86
2.51
2000
0.98
2.26
9.15
126173
0.22
2.26
2.79
2200
1.17
2.70
10.07
138791
0.27
2.70
3.07
2400
1.38
3.17
10.99
151408
0.31
3.17
3.35
2600
1.60
3.68
11.90
164025
0.36
3.68
3.63
2800
1.84
4.22
12.82
176643
0.42
4.22
3.91
3000
2.09
4.79
13.73
189260
0.47
4.79
4.19
3200
2.35
5.40
14.65
201877
0.53
5.40
4.46
3400
2.63
6.04
15.56
214495
0.60
6.04
4.74
3600
2.92
6.71
16.48
227112
0.66
6.71
5.02
3800
3.23
7.42
17.39
239729
0.73
7.42
5.30
4000
3.55
8.16
18.31
252347
0.80
8.16
5.58
4200
3.89
8.93
19.22
264964
0.88
8.93
5.86
4400
4.24
9.73
20.14
277581
0.96
1 9.73
6.14
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST- • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
COPPER W ATER AND FRICTION LOSS PER 100 FEET
Maximum O.D. = 10.1270 inches (257.2258 mm) Nominal O.D. = 10.1230 inches (257.1242 mm)
Minimum O.D. = 10.1190 inches (257.0226 mm) Nominal I.D. = 9.6230 inches (244.4242 mm)
Nominal Wall Thickness = 0.2500 inches (6.3500 mm) Flow Area = 72.7295 sq. inches (46922.19 sq. mm)
Hazen Williams formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m/100 m)
Velocity
(m /sec
200
0.01
0.03
0.88
12617.33
0.00
0.03
0.27
400
0.05
0.11
1.76
25234.67
0.01
0.11
0.54
600
0.10
0.22
2.65
37852.00
0.02
0.22
0.81
800
0.16
0.38
3.53
50469.33
0.04
0.38
1.08
1000
0.25
0.57
4.41
63086.67
0.06
0.57
1.34
1200
0.35
0.80
5.29
75704.00
0.08
0.80
1.61
1400
0.46
1.07
6.18
88321.33
0.11
1.07
1.88
1600
0.60
1.37
7.06
100938.67
0.13
1.37
2.15
1800
0.74
1.70
7.94
113556.00
0.17
1.70
2.42
2000
0.90
2.07
8.82
126173.33
0.20
2.07
2.69
2200
1.07
2.47
9.70
138790.67
0.24
2.47
2.96
2400
1.26
2.90
10.59
151408.00
0.29
2.90
3.23
2600
1.46
3.36
11.47
164025.33
0.33
3.36
3.50
2800
1.68
3.85
12.35
176642.67
0.38
3.85
3.76
3000
1.91
4.38
13.23
189260.00
0.43
4.38
4.03
3200
2.15
4.93
14.12
201877.33
0.49
4.93
4.30
3400
2.40
5.52
15.00
214494.67
0.54
5.52
4.57
3600
2.67
6.13
15.88
227112.00
0.60
6.13
4.84
3800
2.95
6.78
16.76
239729.33
0.67
6.78
5.11
4000
3.25
7.45
17.65
252346.67
0.73
7.45
5.38
4200
3.56
8.16
18.53
264964.00
0.80
8.16
5.65
4400
1 3.88
1 8.89
19.41
277581.33
0.88
1 8.89
1 5.92
Hazen Williams Formula
Maximum O.D. = 10.1270 inches (257.2258 mm) Nominal O.D. = 10.1230 inches (257.1242 mm)
Minimum O.D. = 10.1190 inches (257.0226 mm) Nominal I.D. = 9.6990 inches (247.3546 mm)
Nominal Wall Thickness = 0.2120 inches (5.3848 mm) Flow Area = 73.8829 sq. inches (47666.28 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
Ali 00 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Veloci
(m )sec
200
0.01
0.03
0.87
12617
0.00
0.03
0.26
400
0.04
0.10
1.74
25235
0.01
0.10
0.53
600
0.09
0.21
2.61
37852
0.02
0.21
0.79
800
0.16
0.37
3.47
50469
0.04
0.37
1.06
1000
0.24
0.55
4.34
63087
0.05
0.55
1.32
1200
0.34
0.77
5.21
75704
0.08
0.77
1.59
1400
0.45
1.03
6.08
88321
0.10
1.03
1.85
1600
0.57
1.32
6.95
100939
0.13
1.32
2.12
1800
0.71
1.64
7.82
113556
0.16
1.64
2.38
2000
0.87
1.99
8.68
126173
0.20
1.99
2.65
2200
1.03
2.37
9.55
138791
0.23
2.37
2.91
2400
1.21
2.79
10.42
151408
0.27
2.79
3.18
2600
1.41
3.23
11.29
164025
0.32
3.23
3.44
2800
1.62
3.71
12.16
176643
0.37
3.71
3.71
3000
1.84
4.21
13.03
189260
0.42
4.21
3.97
3200
2.07
4.75
13.90
201877
0.47
4.75
4.24
3400
2.31
5.31
14.76
214495
0.52
5.31
4.50
3600
2.57
5.90
15.63
227112
0.58
5.90
4.76
3800
2.84
6.53
16.50
239729
1 0.64
6.53
5.03
4000
3,13
7.17
17.37
252347
1 0.71
7.17
5.29
4200
3.42
7.85
18.24
264964
1 0.77
7.85
5.56
4400
1 3.73
1 8.56
19.11
277581
1 0.84
1 8.56
5.82
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
F7
COPPER WATER AND FRICTION LOSS PER 100 FEET
Maximum O.D. = 12.1270 inches (308.0258 mm) Nominal O.D. = 12.1230 inches (307.9242 mm)
Minimum O.D. = 12.1190 inches (307.8226 mm) Nominal I.D. = 11.3130 inches (287.3502 mm)
Nominal Wall Thickness = 0.4050 inches (10.2870 mm) Flow Area = 100.5184 sq. inches (64850.43 sq. mm)
Hazen Williams Formula C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
1000
0.11
0.26
3.19
63087
0.03
0.26
0.97
1200
0.16
0.37
3.83
75704
0.04
0.37
1.17
1400
0.21
0.49
4.47
88321
0.05
0.49
1.36
1600
0.27
0.62
5.11
100939
0.06
0.62
1.56
1800
0.34
0.77
5.75
113556
0.08
0.77
1.75
2000
0.41
0.94
6.38
126173
0.09
0.94
1.95
2200
0.49
1.12
7.02
138791
0.11
1.12
2.14
2400
0.57
1.32
7.66
151408
0.13
1.32
2.33
2600
0.67
1.53
8.30
164025
0.15
1.53
2.53
2800
0.76
1.75
8.94
176643
0.17
1.75
2.72
3000
0.87
1.99
9.58
189260
0.20
1.99
2.92
3200
0.98
2.25
10.21
201877
0.22
2.25
3.11
3400
1.09
2.51
10.85
214495
0.25
2.51
3.31
3600
1.22
2.79
11.49
227112
0.28
2.79
3.50
3800
1.34
3.09
12.13
239729
0.30
3.09
3.70
4000
1.48
3.39
12.77
252347
0.33
3.39
3.89
4200
1.62
3.71
13.41
264964
037
3.71
4.09
4400
1.76
4.05
14.04
277581
0.40
4.05
428
4600
192
4.39
14.68
290199
0.43
4.39
4.48
4800
2.07
4.75
15.32
302816
0.47
4.75
4.67
5000
214
5.13
15.96
315433
0.51
5.13
4.86
5200
2.40
5.51
16.60
328051
0.54
5.51
5.06
5400
2.58
5.91
17.24
340668
0.58
5.91
5.25
5600
2.76
6.32
1 17.87 1
353285
1 0.62
1 6.32
1 5.45
5800
2.94
6.75
18.51
365903
0.67
6.75
5.64
6000
3.13
7.18
19.15
378520
0.71
1 7.18
5.84
6200
3.33
7.63
19.79
391137
0.75
1 7.63
6.03
Hazen Williams Formula
Maximum O.D. = 12.1270 inches (308.0258 mm) Nominal O.D. = 12.1230 inches (307.9242 mm)
Minimum O.D. = 12.1190 inches (307.8226 mm) Nominal I.D. = 11.5630 inches (293.7002 mm)
Nominal Wall Thickness = 0.2800 inches (7.1120 mm) Flow Area = 105.0101 sq. inches (67748.29 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(1kPa /100 m)
Head Loss
(m /100 m)
Velocity
(m /sec.)
1000
0.10
0.23
3.06
63087
0.02
0.23
0.93
1200
0.14
0.33
3.67
75704
0.03
0.33
1.12
1400
0.19
0.44
4.28
88321
0.04
0.44
1.30
1600
0.24
0.56
4.89
100939
0.06
0.56
1.49
1800
0.30
0.70
5.50
113556
0.07
0.70
1.68
2000
0.37
0.85
6.11
126173
0.08
0.85
186
2200
0.44
1.01
6.72
138791
0.10
1.01
2.05
2400
0.52
1.19
7.33
151408
0.12
1.19
2.23
2600
0.60
1.37
7.94
164025
0.14
1.37
2.42
2800
0.69
1.58
8.55
176643
016
1.58
2.61
3000
0.78
1.79
9.17
189260
0.18
1.79
2.79
3200
0.88
2.02
9.78
201877
0.20
2.02
2.98
3400
0.98
2.26
10.39
214495
0.22
2.26
3.17
3600
1.09
2.51
11.00
227112
0.25
2.51
3.35
3800
1.21
2.77
11.61
239729
0.27
2.77
3.54
4000
1.33
3.05
12.22
252347
0.30
3.05
3.72
4200
1.46
3.34
12.83
264964
0.33
3.34
3.91
4400
1.59
3.64
13.44
277581
0.36
3.64
4.10
4600
1.72
3.95
14.05
290199
0.39
3.95
4.28
4800
1.86
4.27
14.67
302816
0.42
4.27
4.47
5000
2.01
4.61
15.28
315433
0.45
4.61
4.66
5200
2.16
4.96
15.89
328051
0.49
4.96
4.84
5400
2.32
5.31
16.50
340668
0.52
5.31
5.03
5600
2.48
5.68
1 17.11
353285
0.56
5.68
5.21
5800
2.65
6.07
17.72
365903
0.60
6.07
5.40
6000
1 2.82
6.46
18.33
378520
0.64
6.46
5.59
6200
1 2.99
6.86
18.94
391137
0.68
6.86
5.77
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Hazen Williams Formula
Maximum O.D. = 12.1270 inches (308.0258 mm) Nominal O.D. = 12.1230 inches (307.9242 mm)
Minimum O.D. = 12.1190 inches (307.8226 mm) Nominal I.D. = 11.6150 inches (295.021 mm)
Nominal Wall Thickness = 0.2540 inches (6.4516 mm) Flow Area = 105.9567 sq. inches (68359.01 sq. mm)
C Factor = 150
FLOW, Q
(GPM)
Pressure Loss
(psi /100 ft)
Head Loss
(ft/100 ft)
Velocity
(ft. /sec.)
FLOW, Q
(cu. cm /sec.)
Pressure Loss
(kPa /100 m)
Head Loss
(m/100 m)
Velocity
1000
0.10
0.23
3.03
63087
0.02
0.23
0.92
1200
0.14
0.32
3.63
75704
0.03
0.32
1.11
1400
0.19
0.43
4.24
88321
0.04
0.43
1.29
1600
0.24
0.55
4.84
100939
0.05
0.55
1.48
1800
0.30
0.68
5.45
113556
0.07
0.68
1.66
2000
0.36
0.83
6.06
126173
0.08
0.83
1.85
2200
0.43
0.99
6.66
138791
0.10
0.99
2.03
2400
0.51
1.16
7.27
151408
0.11
1.16
2.22
2600
0.59
1.35
7.87
164025
0.13
1.35
2.40
2800
0.67
1.54
8.48
176643
0.15
1.54
2.58
3000
0.76
1.75
9.08
189260
0.17
1.75
2.77
3200
0.86
1.98
9.69
201877
0.19
1.98
2.95
3400
0.96
2.21
10.30
214495
0.22
2.21
3.14
3600
1.07
2.46
10.90
227112
0.24
2.46
3.32
3800
1.18
2.71
11.51
239729
0.27
2.71
3.51
4000
1.30
2.98
12.11
252347
0.29
2.98
3.69
4200
1.42
3.27
12.72
264964
0.32
3.27
3.88
4400
1.55
3.56
13.32
277581
0.35
3.56
4.06
4600
1.68
3.87
13.93
290199
0.38
3.87
4.25
4800
1.82
4.18
14.53
302816
0.41
4.18
4.43
5000
1.97
4.51
15.14
315433
0.44
4.51
4.61
5200
2.11
4.85
15.75
328051
0.48
4.85
4.80
5400
2.27
5.20
16.35
340668
0.51
5.20
4.98
5600
2.43
5.56
16.96
353285
0.55
5.56
5.17
5800
1 2.59
1 5.93
17.56
365903
0.59
1 5.93
5.35
6000
2.76
6.32
18.17
378520
0.62
6.32
5.54
6200
2.93
6.71
1 18.77
391137
1 0.66
6.71
1 5.72
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Copper Water Tubecontinued
COPPER
Tube Type
STANDARDS,
Color Code
Standard
, LENGTHS
Application
Commercially Available Lengths
Nominal or Standard Sizes Drawn Annealed
Type K
Green
ASTM B 88
Domestic Water Service Distribution
Fire Protection
Solar
Fuel /Fuel Oil
HVAC
Snow Melting
Straight Lengths: 1 /4 -inch to 8 -inch
10 -inch
12 -inch
20 ft. (6.1m)
20 ft. (6.1m)
18 ft. (5.5m)
18 ft. (5.5m)
12 ft. (3.7m)
12 ft. (3.7m)
Coils: '/4 -inch to 1 -inch
1 1 /4 -inch & 1
2 -inch
—
60 ft. (18.3m)
—
100 ft. (30.5m)
—
60 ft. (18.3m)
—
40 ft. (12.2m)
—
4 5 ft. (13.7m)
Type L
Blue
ASTM B 88
Domestic Water Service Distribution
Fire Protection
Solar
Fuel /Fuel Oil
Natural Gas
Liquified Petroleum (LP) Gas
HVAC
Snow Melting
Straight Lengths: '/4 -inch to 10 -inch
12 -inch
20 ft. (6.1m)
20 ft. (6.1m)
18 ft. (5.5m)
18 ft. (5.5m)
Coils: 1 /4 -inch to 1 -inch
1 1 /4 -inch & 1' /2 -inch
2 -inch
—
60 ft. (18.3m)
—
100 ft. (30.5m)
—
60 ft. (18.3m)
—
40 ft. (12.2m)
—
45 ft. (13.7m)
Type M
Red
ASTM B 88
Domestic Water Service Distribution
Fire Protection
Solar
Fuel /Fuel Oil
HVAC
Snow Melting
Straight Lengths: '/4 -inch to 12 -inch
20 ft. (6.1 m)
N/A
DWV
Yellow
ASTM B 306
Drain
Waste
Vent
HVAC
Solar
Straight Lengths: 1'/4 -inch to 8 -inch
20 ft. (6.1 m)
N/A
ACR
Blue
ASTM B 280
Air Conditioning
Refrigeration
Natural Gas
Liquified Petroleum (LP) Gas
Straight Lengths: '/4 -inch to 4 1 /8 -inch
20 ft. (6.1 m)
20 ft. (6.1 m)'
Coils: 1 /e -inch to 1 /e -inch
—
50 ft. (15.3m)'
OXY
MED
OXY /MED
OXY /ACR
ACR/MED
Type K
Green
Type L
Blue
ASTM B 819
Medical Gas
Straight Lengths: 1 /4 -inch to 8 -inch
20 ft. (6.1 m)
N/A
Type G
Yellow
ASTM B 837
Natural Gas
Liquified Petroleum (LP) Gas
Straight Lengths: 3/0- inch to 1'/e -inch
12 ft. (3.7m)
12 ft. (3.7m)'
20 ft. (6.1 m)
20 ft. (6.1 m)
Coils: 3/8- inch to' /e - inch
—
60 ft. (18.3m)'
—
100 ft. (30.5m)'
'Available as special order only.
U.S. customary units in this document are the standard; the metric units are provided for
reference only. The values stated in each system are not exact equivalents.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
The Fine Art
of Soldering
When adjoining surfaces of copper and copper alloys meet under proper conditions of cleanliness and temperature,
solder will make a perfect adhesion. The strength of joint is equal to or even greater than the strength of tube alone.
Surface tension seals the joint. Capillary attraction draws solder into, around, and all about the joint. It's easy to learn
to make a perfect solder joint when you use NIBCO Fittings.
1. Cut tube end square, ream, burr and size.
o �
Apply solder flux to outside of tube and inside of cup
of fitting carefully so that surfaces to be joined are completely
covered. Use flux sparingly.
Remove flame and feed solder into the joint at one or
two points until a ring of solder appears at the end of the fitting.
The correct amount of solder is approximately equal to 1 the
diameter of the fitting... 3 /4" (20mm) solder for '12" fitting, etc.
Use sand cloth or steel wire brush to clean tube and cup to a
bright metal finish.
NO n*o
4. Apply flame to the fitting to heat tube and solder cup of fitting
until solder melts when placed at joint of tube and fitting.
6. Remove excess solder with a small brush or wiping cloth while
the solder is plastic.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
35
The Fine Art
of Brazing
Best results will be obtained by a skilled operator employing the step -by -step brazing technique that follows:
The tube should be cut to desired length with a square cut,
preferably in a square -end sawing vise. The cutting wheel of the
type specifically designed for cutting copper tube will also do a
satisfactory job. The tube should be the exact length needed, so that
the tube will enter the cup of the fitting all the way to the shoulder
of the cup. Remove all slivers and burrs left from cutting the tube, by
reaming and filing, both inside and outside.
2. To make a proper brazing joint, the clearance between the solder
cup and the tube should be approximately 0.001" to 0.010"
(0.0254mm to 0.254mm). Maintaining a good fit on parts to be
brazed insures:
Ease of Application — Excessively wide tolerances tend to break
capillary force; and, as a result the alloy will either fail to flow
throughout the joint or may flush out of the joint.
Corrosion Resistance — There is also a direct relation between the
corrosion resistance of a joint and the clearance between members.
Economy — If brazing alloys are to be used economically, they, of
necessity, must be applied in the joint proper and in minimum
quantities, using merely enough alloy to fill the area between the
members.
0
The surfaces to bejoined must be clean and free from oil,
grease and heavy oxides. The end of the tube
need be cleaned only for a distance
slightly more than it is to
enter the cup. Special f
wire brushes r
designed to clean
tube ends may be
used, but they should
be carefully used so
that an excessive amount
of metal will not be
removed from the tube. Fine sand cloth or emery cloth
may also be used with the same precautions. The cleaning should
not be done with steel wool, because of the likelihood of leaving
small slivers of the steel or oil in the joint.
The cup of the fitting should be
cleaned by methods similar
to those used for the tube
end, and care should be
observed in removing
residues of the cleaning
medium. Attempting to
braze a contaminated or an
improperly cleaned surface will
result in an unsatisfactoryjoint. Brazing alloys will not flow over or
bond to oxides; and oily or greasy surfaces tend to repel fluxes,
leaving bare spots which will oxidize, resulting in voids and
inclusions.
5. Flux should be applied to
the tube and solder cup
sparingly and in a fairly
thin consistency. Avoid
flux on areas not cleaned.
Particularly avoid getting
excess flux into the inside
of the tube itself. Flux has
three principal functions
to perform:
A. It prevents the oxidation of the metal surfaces during the heating
operation by excluding oxygen.
B. It absorbs and dissolves residual oxides that are on the surface
and those oxides which may form during the heating operation.
C. It assists in the flow of the alloy by presenting a clean nascent
surface for the melted alloy to flow over. In addition, it is an
excellent temperature indicator, especially if an indicating flux is
used.
6.
Immediately after fluxing, the parts to be brazed should be
assembled. If fluxed parts are allowed to stand, the water in
the flux will
evaporate, and
dried flux is liable to
flake off, exposing
the metal surfaces
to oxidation from
the heat. Assemble
the joint by inserting
the tube into the
cup, hard against
the stop. The
assembly should be firmly supported so that it will remain in
alignment during the brazing operation.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST- • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
7. Brazing is started by applying heat to the parts to be joined. The
preferred method is by the oxyacetylene flame. Propane and other
gases are sometimes used on smaller sizes. A slightly reducing
flame should be used, with a slight feather on the inner blue cone;
the outer portion of the flame, pale green. Heat the tube first,
beginning at about one inch from the edge of the fitting. Sweep the
flames around the tube in short strokes up and down at right angles
to the run of the tube. It is very important that the flame be in
continuous motion and should not be allowed to remain on any one
point to avoid burning through the tube. Generally, the flux may be
used as a guide as to how long to heat the tube, continuing heating
after the flux starts to bubble or work, and until the flux becomes
quiet and transparent, like clear water. The flux will pass through
four stages:
A. At 212 °F (100 °C) the water boils off.
B. At 600 °F (315.6 °C) the flux becomes white and slightly puffy and
starts to work.
C. At 800 °F (426.7 °C) it lays against the surface and has a milky
appearance.
D. At 1100 °F (593.3 °C) it is completely clear and active and has the
appearance of water.
Now switch the flame to the fit
base of the cup. Heat uniformly
sweeping the flame from the
fitting to the tube until the flux
the fitting becomes quiet.
Avoid excessive heating
of cast fittings.
When the flux appears liquid
and transparent on both the
tube and the fitting, start sweeping
the flame back and forth along the axis of the joint to maintain heat
on the parts to be joined, especially toward the base of the cup of
the fitting. The flame must be kept moving to avoid burning the tube
or the fitting.
10. Apply the brazing wire or rod at a point
where the tube enters the sock+ -C."-
fitting. The temperature of the j
should be hot enough to melt tf
brazing alloy. Keep the flame a1
from the rod or wire as it is fed
into the joint. Keep both the
fitting and the tube heated by
moving the flame back and
forth from one to the other
as the alloy is drawn into the
joint. When the proper
temperature is reached, the alloy will flow readily into the space
between the tube outer wall and the fitting socket, drawn in by the
natural force of capillary attraction. When the joint is filled, a
continuous fillet of brazing alloy will be visible completely around
the joint. Stop feeding as soon as the joint is filled, using table on
page 54 as a guide for the alloy consumption.
NOTE: For tubing one inch and larger, it is
difficult to bring the whole joint up to heat
at one time. It frequently will be found
desirable to use a double -tip torch to
maintain the proper temperature over the
larger area. A mild pre- heating of the
whole fitting is recommended. The
heating then can proceed as in steps 7, 8,
9, and 10. If difficulty is encountered in
getting the whole joint up to heat at one
time, then when the joint is nearly up to
the desired temperature the alloy is
concentrated in a limited area. At the
brazing temperature the alloy is fed into
the joint and the torch is then moved to an
adjacent area and the operation carried
on progressively all around the joint.
HORIZONTAL JOINTS — When making
horizontal joints, it is preferable to
start applying the brazing alloy at the
5 o'clock position, then move around
to the 7 o'clock position and then
move up the sides to the top of the
joint, making sure that the
operations overlap.
VERTICAL JOINTS — On vertical
joints, it is immaterial where the
start Is mane. IT the opening or the
cup is pointed down, care should be taken to avoid overheating the
tube, as this may cause the alloy to run down the tube. If this condition
is encountered, take the heat away and allow the alloy to set. Then
reheat the solder cup of the fitting to draw up the alloy.
After the brazing alloy has set,
remove residual flux from the joint
area as it is corrosive and presents
an unclean appearance and
condition. Hot water or steam and a
soft cloth should be used. Wrot
fittings may be chilled; however it is
advisable to allow cast fittings to
cool naturally to some extent before
applying a swab. All flux must be removed before inspection and
pressure testing.
TROUBLE SPOTS
If the alloy fails to flow or has a tendency to ball up, it indicates
oxidation on the metal surfaces, or insufficient heat on the parts to
be joined. If work starts to oxidize during heating, it indicates too
little flux, or a flux of too thin consistency. If the brazing alloy
refuses to enter the joint and tends to flow over the outside of either
member of the joint, it indicates this member is overheated, or the
other is underheated, or both. In both cases, operations should be
stopped and the joints disassembled, recleaned and fluxed.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Po I eth y lene
I I
(PE lubing
FITTING SYSTEM — INSERT /CRIMP TYPE*
Making a Connection
1. Using a tube cutter, cut tubing squarely and remove burrs.
3. Insert ribbed fitting into tubing until tubing contacts the fitting shoulder
(tube stop). Position the crimp ring on the tubing so
that the edge of the ring is 1/8" to 1/4" (3 to 6mm) from the
end of the tube.
4. Center the crimping tool jaws exactly over the ring while maintaining its
position relative to the fitting. Crimp the ring by closing the handles
together to the positive stop on the tool. Check the after - crimped
diameter of each ring with the crimp gauge. If the small flats on the
gauge do not fit over the crimped ring, the ring is under - crimped. Cut out
any under - crimped rings and fittings and completely replace. DO NOT
RE- CRIMP.
*NIBCO recommends the use of copper crimp rings ONLY and a properly calibrated
full circle crimping tool for joining PEX tubing and copper barbed fittings.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
Polybutylene
Tubing
Making a Connection
Using a tube cutter,
cut tubing squarely
and remove burrs.
3. Insert fitting into tubing, then position crimp ring squarely
over barbs. Proper alignment is important for making the
best connection.
TOOLS AND RINGS
• Use tools recommended by fitting and tubing manufacturers.
All tools must make a full - circle crimp.
• Check tool adjustment at least daily, and readjust as necessary.
• Use crimp rings of copper as recommended by NIBCO INC.
2. Slide copper crimp ring on tubing. Only copper crimp rings should be
used to ensure the highest quality connection.
4. Center the crimping tool jaws exactly over the ring, and bring
the tool handles together until totally closed to the stop indicator. Check
each crimp ring with the caliper gauge after completion.
If the small flats on the gauge do not fit over the crimped ring,
the ring is undercrimped. Cut out any undercrimped rings and fittings,
and completely replace.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455
n
J_
Frequently Asked
Questions
Q: What is the pressure rating of a given fitting? Q: Can dissimilar metals (i.e., copper and iron) be joined together
A: Fittings are rated per Table 1 of ASME 616.22. The system rated without use of dielectric insulators to prevent corrosion?
pressure shall be the lowest of the fitting, tube or joint. A: In most situations dissimilar metals (copper /iron /steel) can be
joined successfully without using dielectric insulators. Factors to
consider:
Q: When copper fails in a system, what is the problem? 1. The composition of the two metals.
A: MOST COMMON: 2. The rate of liquid flow past the two metals.
1. Velocity — fluid is moving too fast. Recommendation:
2 -3 fps (0.0508 - 0.0762 m /s) hot water 140 °F, 5 -8 fps (0.127-
0.2032 m /s) cold water. Refer to pages 68 -93.
2. Turbulence — burrs left on the cut tubing causes a tumbling
effect causing localized erosion and eventual failure.
3. Aggressive Waters — tend to cause pitting or green staining of
fixtures. Aggressive, hard well waters that cause pitting
typically are found to have total dissolved solids including
suflates and chlorides, a pH in the range of 7.2 to 7.8, a high
content of carbon dioxide gas and the pressence of dissolved
oxygen gas. Soft acidic waters that cause green staining
typically tend to be more corrosive. Low alkalinity, low
mineralization, pH levels of 7 or lower should be avoided.
LESS COMMON:
1. Flux Corrosion —using too much flux when making
joints can potentially leave residue and cause isolated
corrosion. Flux should be used sparingly and system adequately
flushed.
2. Electrolysis — stray (D.C.) current; inadequate grounding for the
piping.
3. Sand or other solid particulates — erosion /corrosion problems
can occur. Lower velocities must be maintained
if solids are present in flow media.
4, Galvanic Corrosion — destruction of a material by
electrochemical interaction between the environment
and the material.
Q: Copper tubing wall thickness is designated "K," "L" or "M." What
are the copper fittings applicable to?
A: Copper fittings' wall thickness is determined by standards (ASME
B -16:22 and MSS -SP -104). These standards address minimum wall
thickness (per size) for the full range of copper fittings and are not
intended to match tubing wall thicknesses.
3. Chemicals in the water which could enhance or destroy
protective films.
4. The relative areas of the two metals - unless the surface area
of the less noble (steel) material is less that 5% of the more
noble (copper) material, the need for a dielectric separator is
not needed. (Failures due to galvanic corrosion are very unusual
and only occur under very strict conditions.)
5. Local code requirements.
Q: What should the installer of copper unions know and do in order to
assure a proper leak -free installation?
A. The following should be done:
1. Make sure the ground joint(mating area of unionis tail and
thread pieces) are free of nicks and scratches.
2. Spray the ground joint area with a food grade silicone spray or
apply bees wax to enhance seating.
3. Make sure alignment of line does not put lateral stress on the
ground joint seal.
4. Make sure that excess solder (droplets) do not reach the
ground joint area.
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY SL • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
°°�,� Residential
G
50-YEAR Cop Plumbin V
\ LU1IIEUN'ARRANTY Limited Warrant
What the warranty terms mean
In this warranty "Manufacturer" refers to the company listed below
which manufactured the Product and any person or company that
assumes its obligations under this warranty. "Homeowner" means
you as the owner of the residential building in the United States in
which the Product has been installed and also means any succeeding
owner during the original warranty term. "Product" means the copper
water tube and /or copper or brass fittings manufactured by the
Manufacturer for the residential building market in the United States.
Each Manufacturer listed below separately and individually warrants
only Products it has manufactured and does not warrant Products of
any other company, whether or not listed below.
Date the warranty begins
The warranty begins on the date of the new home purchase,
or in the case of home additions or renovations, on the date the
installation is completed. The warranty is transferable to succeeding
Homeowners for the remainder of the original warranty term, in
which case the date the warranty begins shall continue without
change.
What is covered
The Manufacturer warrants to the Homeowner for a period
of 50 years from the date the warranty begins that its properly
installed Product will be free of failure as a result of defects in
material or workmanship in manufacturing the Product.
What the manufacturer wiI I do for you
As long as (1) such a failure occurs within 50 years from the date the
warranty begins and (2) the Homeowner promptly notifies the
Manufacturer of the Product of that failure by contacting it through its
800 phone number listed below, the Manufacturer will correct that
failure by repairing or replacing the Product within a reasonable time,
without charge. This warranty is limited to the cost of repairing or
replacing the Product, including installation.
NIBCO TECHNICAL SERVICE
1- 888 - 446 -4226
Products
What is not covered: Disclaimer of liability for consequential
and other damages
The Manufacturer does NOT warrant against failure:
1. of any product, parts, or systems that it has not manufactured;
2. if the Product is used for purposes other than residential
plumbing applications;
3. caused by, contributed in whole or in part by, or resulting from,
any of the following:
(a) improper installation;
(b) abuse, such as, without limitation, vandalism;
(c) natural disasters, such as, without limitation, flooding,
windstorm and lightning;
(d) attachments or modifications to the Product that the
Manufacturer did not authorize;
(e) external causes, where external, physical or chemical
qualities produce damage to the Product, such as, without
limitation, aggressive water or an unsuitable or hostile
environment; or
(f) any other cause beyond the Manufacturer's control.
The Manufacturer shall NOT be liable under any circumstances for
any other direct or any indirect, incidental or consequential damages
of any kind.
This is the only warranty
This warranty is the only warranty for the Product provided by the
Manufacturer, and is and shall be in lieu of any and all other
warranties, express or implied, including but not limited to an implied
warranty of merchantability, and of all other obligations or liabilities
on the part of the Manufacturer. None of the Manufacturer's
employees, and no other person or business, is authorized to make
any other warranty on the Manufacturer's behalf covering the
product.
This warranty gives you specific legal rights, and you may also have
other rights which vary from state to state. Some states do not allow
the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you.
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.514.295.3221 • FAX: +1.514.295.3455
711 F
Numerical Index
Figure
Number Paae
100 Series
Cast Heavy Flared
101 ............................... 23
104 ............................... 23
500 Series Cast Flared
500 ..............................
24
503 ..............................
23
504 ..............................
23
507 ..............................
23
507 -3 ...........................
23
507 -4 ...........................
23
511 ...............................
24
600 Series
Wrot Pressure
600 . ............................... 9
600 - 2 ...........................15
736 .............................11
600 -DS ........................10
739 . .............................16
600 -RS .........................9
741 .. .............................15
601 . .............................10
748 .............................
603 . ...............................
6
603- 2 .............................
6
604 . ...............................
7
604 -2 .. . ..........................
7
606 . .............................11
764 . .............................15
606 - 2 ...........................11
771 . .............................16
607 . .............................12
775 . .............................16
607 -2 ...........................13
805 ..............................
607 -2 -2 ........................13
805 -N ..........................
607- 2- 2- LT ....................13
806 ..............................
607 -2- 1 .........................13
806- 2 ...........................
607 -2 -LT .......................13
807 ..............................
607 - 1 ............................12
807 -2 ...........................
607 -LT ..........................12
807 -3 ...........................
611 ......................... 17 -19
611 - 2 ............................19
36
616 . .............................16
36
617 . ...............................
9
618 . ...............................
8
618- 3 .............................
8
619 ...............................
8
620 -L ............................
8
621 ..............................
21
623 . .............................16
38
624 . .............................16
38
633 -W .........................
21
638 . .............................16
33
698 ..............................
20
Figure
Number Page
700 Series
Cast Pressure
701 . .............................10
701- D ...........................10
702 .............................10
703 . ............................... 6
703- 2 ............................. 6
703 -5 ............................ 6
703 -513 .......................... 6
704 . ............................... 7
704- 2 ............................. 7
704 -2 -H ......................... 8
704 -F ............................. 7
704 -H ............................ 7
705 . .............................16
705- D ...........................17
706 - 2 ...........................12
707 . .............................12
707 -2 -4 ........................13
707 -3 ...........................14
707 -3 -5 ........................14
707 -3 -5 -A ....................14
707 -3 -6 ........................14
707 -4 ...........................14
707 -4 -6 ........................14
707 -5 ...........................14
707- 5- A ........................14
707 -6 ...........................15
708 . .............................15
710 -3 ...........................17
710 -3 -4 . .......................17
711 . .............................19
711 -5 ...........................19
711- A ...........................19
712 .............................. 20
712- 5 ........................... 20
713 ............................. 20
714 .............................. 20
717 . ............................... 9
717- D ............................. 9
718 -3 ............................. 8
724 -5 -A ......................10
733 .............................. 21
733- 2 ........................... 21
733- 3 ........................... 21
733- 4 ........................... 21
Figure
Number Paae
735 . .............................11
34
736 .............................11
33
739 . .............................16
31
741 .. .............................15
32
748 .............................
21
749 .............................
21
750 . ...............................
8
750- 3 .............................
8
750- 4 .............................
8
764 . .............................15
32
771 . .............................16
33
775 . .............................16
33
800 Series Cast DWV
801 ..............................
34
801 -2 ...........................
33
801 -2 -7 ........................
31
801- T ............................
32
802 ..............................
32
802- C ...........................
32
802 -F ...........................
32
803 ..............................
32
803- 2 ...........................
32
804 ..............................
32
804- 2 ...........................
33
804 -T ...........................
33
805 ..............................
31
805 -N ..........................
31
806 ..............................
35
806- 2 ...........................
35
807 ..............................
35
807 -2 ...........................
35
807 -3 ...........................
36
807 -4 ...........................
36
807 -9 ...........................
36
808 ..............................
36
809 ..............................
36
810 ..............................
38
811 ..............................
37
811- 14 ..........................
37
811- 15 ..........................
37
812 ..............................
38
814 ..............................
38
816 ..............................
33
816- S ...........................
33
818 A.S.A ....................
36
834 ..............................
38
835 ..............................
37
835- B ...........................
37
836 ..............................
38
Figure
Number Paae
837 ..............................
36
851 ..............................
34
851 -C ...........................
34
861 -LH .........................
36
875- S ...........................
40
878 ..............................
40
879 ..............................
40
880 ..............................
39
881 ..............................
39
884 ..............................
39
885 ..............................
39
890 ..............................
39
891 ..............................
39
892 ..............................
39
892 -3 ...........................
39
892- A ...........................
39
900 Series Wrot DWV
901 ..............................
34
901 -2 ...........................
33
901 -2 -7 ........................
31
901 -2 -F ........................
33
901- 7 ............................
31
901 -RP .........................
34
903 ..............................
32
903- 2 ...........................
32
903 -7 ...........................
31
904 ..............................
33
904 -7 ...........................
31
905 ..............................
31
906 ..............................
35
906- 2 ...........................
35
907 ..............................
35
907 -2 ...........................
35
907 -LT ..........................
35
911 ..............................
37
917 -B ...........................
37
951 ..............................
34
960 ..............................
36
Copper Insert Fittings for
Polybutylene
PB198 ..........................
29
PB600 ..........................
29
PB600 -FA ....................
29
PB607 ..........................
29
PB607- FA .....................
29
PB611 ..........................
29
Figure
Number Paae
Copper Insert Fittings for
Polyethylene (PEX)
PEX 198 .........................26
PEX600 .........................26
PEX600 .........................26
PEX600- 2 ......................26
PEX600 -FA ...................26
PEX600- T ......................26
PEX603 .........................26
PEX604 .........................26
PEX607 .........................26
PEX607 -FA ...................26
PEX611 .........................26
PEX707 -3 -5 ..................26
PEX841 .........................27
PEX100 .........................27
PEX616 ..........................27
m NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
NOTES
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.514.295.3455
NOTES
® NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL SERVICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
globally t o n n e ct i n
It's a new age of
business, and a
new way at
NIBCO. From Elkhart,
Indiana to Lodz, Poland,
and points beyond, our
company has integrated
manufacturing, distribu-
tion, and networked con
tions to provide a seaml,
of information and service, 24
hours a day, 7 days a week. But
this integration hasn't hap-
pened overnight. It's been part
of a long -term strategic process
that has pushed us to reconsid-
er every aspect of our business.
The result? We're a vertically
integrated manufacturer with
the products and systems in
place to deliver low cost and
high quality. NIBCO's products
are manufactured under a
Quality Management System
conforming to the current revi-
sion of ISO -9001 International
Standards. We know the flow
control industry is only going to
get more demanding, and we
are more than ready. We will
continue to lead. That's what
NIBCO is all about.
World
Headquarters
NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEBURY ST. • ELKHART, IN 46516 -4740 • USA • PH: 1.800.234.0227
TECH SERVICES PH:1.888.446A226 • FAX: 1.800.336.4226 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455
www.nibco.com
FITTINGS
Wrot and cast copper pressure fittings • Wrot and cast copper drainage
fittings • Wrot copper PEXlinke fittings • Cast copper alloy flared fittings • Cast
copper alloy flanges • ABS and PVC DWV fittings • Schedule 40 PVC pressure
fittings • CPVC CTS fittings • CPVC CTS- to-metal transition fittings • Schedule 80
PVC and CPVC systems • CPVC metric piping systems.
VALVES & ACTUATION
Pressure -rated bronze, iron and alloy -iron gate, globe and check valves • Pressure -
rated bronze ball valves • Boiler specialty valves • Commercial and industrial
butterfly valves • Circuit balancing valves • Carbon and stainless steel ball valves •
ANSI flanged steel ball valves • Pneumatic and electric actuators and controls
- Grooved ball and butterfly valves • High performance butterfly valves • UL /FM
fire protection valves • MSS specification valves • Bronze specialty valves • Low -
pressure gate, globe, check and ball valves • Frostproof sillcocks • Quarter -turn
supply stops • PVC ball valves • CPVC CTS ball valves • Just Right recirculating
valves.
CHEMTROL®
Thermoplastic pipe, valves and fittings in PVC, Corzan® CPVC, polypropylene
and PVDF Kynar • Chem -Aire" thermoplastic compressed air piping systems
• Pneumatic and electric actuation systems.
Corzan' is a registered trademark of Nmeon. IP Holdings Corp
Kynar' is a registered trademark of ATOFINA Chemicals, Inc
TOLCOrm
NIBCO' now offers complete support with its newest addition of TOLCO' brand
piping solutions including: Pipe attachments • Structural attachments • Pipe
rollers • Threaded products and accessories • Seismic components •
Vibration isolation • Standard and specialty supports • TOL- Strut channel
and components.
. 011
A suite of services designed to make customers more efficient • More cost- effective
• More informed • EDI— Electronic Data Interchange • VMI— Vendor Managed
Inventory • NIBCO.com • NIBCOpartnercom • eNIBCO will continuously
develop new products to deliver the competitive advantage.
NIBC
O
AHEAD OF THE FLOW
NIBCO INC. 1516 MI DDLEBURI STREET DOMESTIC CUSTOMER SERVICE TECHNICAL SERVICE
WORLD HEADQUARTERS ELKHART, IN 465164740 PHONE 800 234 0227 PHONE. 888 446 4226
WEB www nibco. com USA FAX 800 234 0557 FAX 888 336 4226
INTERNATIONAL OFFICE
PHONE «1/574 295 3221
FAX .1/574 295 3455
C- CF-0404 0 2004, NIBCO INC Printed in USA